Table of Contents
INDEX
- addresses
- MAC-layer 1-16
- physical interface 1-14
- ports 1-14
- American National Standards Institute
- See ANSI
- ANSI
- ATM standardization 2 -20
- X3.1 standard 2 -15
- ASP, LightStream 1010 module 6-15
- See also LightStream 1010 ATM modules
- ATM LAN Emulation switching modules
- cables and connectors 2 -18 to 2 -20
- features 6-2
- specifications A -10
- UNI specification 2 -20
- ATM Switch Processor
- See ASP
- ATM-Fabric Integration Module
- See WS-X5165
- audience description xi
- BISDN 2 -20
- blank module carriers 3-5
- BNC connector
- See connectors
- bodily injury warnings
- lifting the chassis B -2
- bridge taps, using with CDDI 2 -14
- Broadband Integrated Services Digital Network
- See BISDN
- bypass switch, optical
- description 2 -15
- output signals, mini-DIN connector A -26
- cables
- configuring additional connection equipment 2 -2
- distance limitations
- CDDI 2 -14
- Ethernet 2 -6
- Fast Ethernet 2 -7
- FDDI 2 -15
- Ethernet transceiver A -22
- fiber optic
- link attenuation and dispersion limits 2 -10
- multimode 2 -6, 2 -11, 2 -18, 3-17
- single-mode 2 -11, 2 -18, 3-16
- optical bypass A -26
- pinout specifications A -27
- precautions for CDDI 2 -14
- preparing network connections 2 -2
- UTP
- Category 3 2 -7
- Category 5 2 -7, 2 -13, 2 -18, 2 -20
- cabling
- FTP, for CDDI 2 -10
- RG-59 2 -21
- CAM, LightStream 1010 ATM module 6-15
- See also LightStream 1010 ATM modules
- captive installation screws
- on modules 3-6
- carrier modules
- See CAM
- Catalyst 8500 line modules, use in a Catalyst 5500 10-2
- Catalyst 8500 Series switch route processor, use in a Catalyst 5500 10-2
- Catalyst 5000 series switches
- description 1-1 to 1-10
- Category 3 UTP 2 -7
- Category 5 UTP 2 -7, 2 -13
- CAU 8-5
- CDDI
- features 5-2
- module software 5-2
- CDDI module
- See WS-X5103 5-1
- CDDI switching modules
- specifications A -9
- chassis
- installation 3-1
- warnings
- lifting B -2
- commands
- show module 3-25
- show port 1-16, 3-25
- concentrator, on CDDI/FDDI networks 2 -15
- connectors
- BNC 2 -21
- DIN 2 -15, A -26
- Ethernet A -22
- MIC 2 -14
- connecting FDDI modules 3-18
- MII for Fast Ethernet 2 -3, A -22
- mini-DIN A -26
- MT-RJ 2 -3, 3-12, 4-9, 4-15, 4-17
- optical bypass switch A -26
- pinouts, straight-through cable A -27
- RG-59 6-6
- RJ-21 2 -5
- RJ-21 telco
- output signals A -24
- RJ-21 telco, Ethernet
- RJ-45
- ATM 2 -20
- connecting CDDI modules 3-18
- Fast Ethernet 2 -3
- output signals A -24
- RJ-45, CDDI
- SC fiber optic
- connecting ATM LANE modules 3-21
- Fast Ethernet 2 -3
- ST fiber optic
- connecting FDDI modules 3-18
- Ethernet 2 -3
- ST fiber optic, FDDI 2 -15
- VF-45 2 -26
- controlled access unit
- See CAU
- Copper Distributed Data Interface
- See CDDI
- DAS 2 -16
- DIN connector 2 -15, A -26
- distance limitations
- CDDI cables 2 -14
- Ethernet cables 2 -6
- Fast Etherent cables 2 -7
- FDDI cables 2 -15
- DS3 ATM interface 6-6
- dual ring 2 -16
- dual-attachment station
- See DAS
- EARL 1-17
- EIA/TIA-568 standard for CDDI cabling 2 -13
- Enhanced Address Recognition Logic
- See EARL
- ESD
- prevention 3-2
- Ethernet
- cables A -22
- connector output signals A -22
- transceiver 2 -6
- Ethernet switching modules
- connectors and cables 2 -3 to 2 -7
- See product number, for example, WS-X5012
- specifications A -5
- fabric integration module (FIM)
- See WS-X5165 and WS-X5305
- Fast EtherChannel feature 4-10, 4-18
- Fast Ethernet switching modules
- cables and connectors 2 -3 to 2 -7
- specifications A -5
- FDDI
- cables and connectors 2 -7 to 2 -18
- features 5-2
- module software 5-2
- optical bypass switch, description 2 -15
- FDDI modules
- See WS-X5101 or WS-X5104
- FDDI switching modules
- optical bypass switch
- output signals A -26
- specifications A -9
- Fiber Distributed Data Interface
- See FDDI
- fiber Token Ring
- See WS-X5031 fiber Token Ring module
- fiber-optic cable
- link attenuation and dispersion limits 2 -10
- multimode 2 -6, 2 -18
- single-mode 2 -11, 2 -18
- filler plate, module 3-5, 3-6
- FIM
- See WS-X5165 and WS-X5305
- foil twisted-pair
- See FTP
- FTP
- CDDI and FDDI 2 -10
- maximum cable length for CDDI 2 -14
- functionality, switching modules 1-14
- GBIC
- description 4-28, 4-32
- optical power characteristics 2 -9
- port restrictions 4-29
- styles 4-29, A -7
- usage restriction 4-30
- Gigabit EtherChannel switching module
- See WS-X5410 Gigabit EtherChannel switching module
- Gigabit Ethernet switching module
- See WS-X5403 Gigabit Ethernet switching module
- Gigabit Interface Converter
- See GBIC
- group switching Ethernet and Fast Ethernet modules
- specifications A -3
- hot-swapping modules 1-17, 1-18
- ILMI 2 -20
- installation screws, captive
- on modules 3-6
- tools required 3-1
- installing modules 3-2 to 3-24
- Integrated Local Management Interface
- See ILMI
- International Telecommunication Union Telecommunication Standardization Sector
- See ITU-T
- Internet Protocol
- See IP
- IP 2 -20
- ISO 9314 standard for CDDI/FDDI 2 -15
- ITU-T 2 -20
- Layer 3-Fabric Integration Module
- See WS-X5305
- lifting the chassis warning B -2
- LightStream 1010 ATM modules
- ASP module 6-15
- ATM modules 1-4
- ATM switch processor module 3-5
- CAMs 6-15
- description 6-15
- port adapters 6-15
- LightStream 1010 port adapters, use in a Catalyst 5500 10-4
- MAC-layer address
- allocation 1-16
- description 1-14
- Management Information Base
- See MIB
- media access control
- See MAC
- MIB 2 -20
- MIC connector 2 -14
- connecting FDDI modules 3-18
- MII connector
- output signals A -22
- used with Fast Ethernet 2 -3
- mode-conditioning patch cord 4-29, 4-33, A -9
- module functionality
- EARL 1-17
- hot swapping 1-17
- MAC-layer address 1-14
- MAC-layer address allocation 1-16
- physical interface addresses 1-14
- port addresses 1-14
- modules
- blank module carriers 3-5
- filler plate 3-6
- hot swapping 1-18
- installing switching modules 3-2 to 3-24
- LightStream 1010 ATM 6-15
- removing 3-9
- MPOA
- components for MBMA network 6-2
- description 6-2
- MSAU 8-5
- MT-RJ
- See connectors
- multimode fiber-optic cable
- ATM LANE 2 -18
- connecting FDDI modules 3-17
- Ethernet and Fast Ethernet 2 -6, 2 -7
- FDDI 2 -11
- multiprotocol over ATM
- See MPOA
- multistation access unit
- See MSAU
- NAM
- See WS-X5380
- neighbors, upstream and downstream 2 -18
- Network Analysis Module
- See WS-X5380
- network connections, preparing 2 -2
- optical bypass switch
- description 2 -15
- output signals, mini-DIN connector A -26
- optical bypass switch, FDDI 5-6, 5-8
- optical sources, types 2 -18
- output signals
- Ethernet 10BaseT RJ-21 telco connector A -24
- Fast Ethernet MII connector A -22
- mini-DIN connector A -26
- RJ-45 Fast Ethernet connector A -24
- PHY 2 -16
- physical interface addresses 1-14
- physical layer interface module
- See PLIM
- pinouts, straight-through cable connectors A -27
- PLIM 2 -20
- port adapter, LightStream 1010 ATM module 6-15
- See also LightStream 1010 ATM modules
- port addresses 1-14
- precautions, CDDI cabling 2 -14
- protection coils, using with CDDI 2 -14
- related documentation xiii
- removing modules 3-9
- ring in/ring out ports 8-5
- ring recovery, description 2 -17
- RJ-21 telco connector
- output signals A -24
- See connectors
- RJ-21connector
- See connectors
- RJ-45
- See connectors
- RJ-45 connector
- ATM 2 -20
- connecting CDDI modules 3-18
- Fast Ethernet 2 -3
- RMON support, network analysis module 9-1
- Route Switch Module
- See WS-X5302 Route Switch module
- safety warnings, translated B -1 to B -3
- SC connector
- connecting ATM LANE modules 3-21
- Fast Ethernet 2 -3
- shared services, using with CDDI 2 -14
- show module command 3-25
- show port command 1-16, 3-25
- signals, output
- MII connector A -22
- mini-DIN connector A -26
- RJ-21 telco connector A -24
- RJ-45 connector A -24
- Simple Network Management Protocol
- See SNMP
- single-attachment station
- See SAS
- single-mode fiber-optic cable
- ATM LANE 2 -18
- connecting FDDI modules 3-16
- FDDI 2 -11
- SNMP 2 -20
- SONET 2 -20
- specifications
- ATM LAN Emulation switching modules A -10
- ATM LANE/MPOA modules A -13
- CDDI and FDDI switching modules A -9
- CDDI module A -9
- connector output signals and cable pinouts A -21 to A -28
- Ethernet and Fast Ethernet switching modules A -5
- fabric integration modules A -20
- FDDI module (MMF) A -9
- FDDI module (SMF) A -9
- fiber Token Ring module A -18
- Gigabit Ethernet and EtherChannel switching modules A -7
- group switching Ethernet and Fast Ethernet modules A -3
- network analysis module A -20
- route switch module A -19
- Token Ring modules A -18
- WS-X5166 DS3 ATM module A -16
- ST connector
- connecting FDDI 3-18
- Ethernet 2 -3
- FDDI 2 -15
- straight-through cable connectors, pinouts A -27
- switch, optical bypass
- description 2 -15
- output signals, mini-DIN connector A -26
- switches, Catalyst 5000 series
- description 1-1 to 1-10
- switching modules, Catalyst 5000 series 1-11
- Synchronous Optical Network
- See SONET
- Token Ring modules
- See WS-X5030 and WS-X5031
- tools
- required for installation 3-1
- transceivers
- Ethernet 2 -6, A -22
- multimode fiber-optic type 2 -11
- single-mode fiber-optic type 2 -11
- translated safety warnings B -1 to B -3
- twisted-pair cable pinouts,Token Ring 2 -24
- UDP 2 -20
- UNI specification 2 -20
- User Datagram Protocol
- See UDP
- User-Network Interface
- See UNI
- UTP
- Category 3 2 -7
- Category 5 2 -7, 2 -13, 2 -18, 2 -20
- maximum transmission distances
- ATM LANE 2 -18
- Ethernet and Fast Ethernet 2 -7
- Versatile Interface Processor 2
- See VIP2
- VF-45 connector 2 -26, 8-4
- VIP2 module
- configuration options 7-7
- description 7-6 to 7-8
- port adapter hardware 7-8
- Volition VF-45 connector
- See VF-45 connector
- warnings
- chassis
- lifting B -2
- WS-X5011 Ethernet switching module
- description 4-4
- specifications A -5
- WS-X5012 Ethernet switching module
- description 4-5
- specifications A -5
- WS-X5012A Ethernet switching module
- description 4-6
- specifications A -5
- WS-X5013 Ethernet switching module
- description 4-7
- specifications A -5
- WS-X5014 Ethernet switching module
- description 4-8 to 4-9
- slot restrictions 4-8
- specifications A -5
- WS-X5015 Ethernet switching module
- description 4-9 to 4-10
- specifications A -5
- WS-X5020 Group Switching Ethernet module
- specifications A -5
- WS-X5020 Group switching Ethernet module
- description 4-25 to 4-26
- WS-X5030 Token Ring module
- description 8-2 to 8-4
- specifications A -18
- WS-X5031 fiber Token Ring module
- description 8-4 to 8-5
- specifications A -18
- WS-X5101 FDDI module
- BYPASS connector 5-6
- description 5-4 to 5-6
- specifications A -9
- WS-X5103 CDDI module
- cabling 2 -10 to 2 -18
- cabling requirements 2 -13
- description 5-2 to 5-4
- specifications A -9
- WS-X5104 FDDI module
- BYPASS connector 5-8
- description 5-6 to 5-8
- specifications A -9
- WS-X5111 Fast Ethernet switching module
- description 4-10 to 4-11
- specifications A -5
- WS-X5113 Fast Ethernet switching module
- description 4-12
- specifications A -5
- WS-X5114 Fast Ethernet switching module
- description 4-13 to 4-14
- specifications A -5
- WS-X5156 ATM LANE UTP module
- description 6-3
- LEDs 6-5
- specifications A -10
- WS-X5157 ATM OC-3 LANE SMF module
- description 6-4 to 6-5
- LEDs 6-5
- specifications A -10
- WS-X5158 ATM OC-3 LANE MMF module
- description 6-4
- LEDs 6-5
- specifications A -10
- WS-X5161 ATM OC-12 LANE/MPOA MMF module
- description 6-11 to 6-13
- DIAG PORT connector 6-12
- specifications A -13
- WS-X5162 ATM OC-12 LANE/MPOA SMF module
- description 6-14
- DIAG PORT connector 6-14
- specifications A -13
- WS-X5165 fabric integration module
- description 10-4 to 10-6
- specifications A -20
- WS-X5166 DS3 ATM module
- description 6-6 to 6-8
- specifications A -16
- WS-X5167 ATM OC-3 LANE/MPOA MMF module
- description 6-8 to 6-10
- specifications A -13
- WS-X5168 ATM LANE/MPOA module
- DIAG PORT connector 6-11
- WS-X5168 ATM OC-3 LANE/MPOA SMF module
- description 6-10 to 6-11
- specifications A -13
- WS-X5201 Fast EtherChannel switching module
- description 4-10 to 4-11
- specifications A -5
- WS-X5201R Fast EtherChannel Backbone switching module
- description 4-14 to 4-15
- EtherChannel support 4-14
- specifications A -5
- WS-X5203 Fast EtherChannel switching module
- description 4-18 to 4-19
- Fast EtherChannel support 4-18
- specifications A -5
- WS-X5213A Fast Ethernet switching module
- description 4-18 to 4-19
- specifications A -5
- WS-X5223 Group switching Fast Ethernet module
- description 4-27 to 4-28
- WS-X5224 Workgroup Fast Ethernet switching module
- description 4-20 to 4-21
- specifications A -5
- WS-X5225R Fast Ethernet switching module
- description 4-21 to 4-22
- Fast EtherChannel support 4-21
- specifications A -5
- WS-X5234-RJ45 Fast Ethernet switching module
- description 4-22 to 4-23
- Fast EtherChannel support 4-22
- WS-X5236-FX-MT Fast Ethernet switching module
- description 4-15 to 4-16
- Fast EtherChannel support 4-15
- WS-X5237-FX-MT Fast Ethernet switching module
- description 4-17 to 4-18
- Fast EtherChannel support 4-17
- WS-X5239-RJ21 Fast Ethernet switching module
- description 4-24 to 4-25
- Fast EtherChannel support 4-24
- WS-X5302 Route Switch module
- configuring, reference information 3-25
- connecting 3-24
- description 1-5, 7-1 to 7-3
- IOS features 7-3
- pinouts, console and auxiliary ports A -28
- specifications A -19
- switch support 1-13, 3-3
- WS-X5305 fabric integration module
- description 10-1 to 10-3
- specifications A -20
- WS-X5380 network analysis module
- description 9-1 to 9-3
- RMON support 9-2
- specifications A -20
- WS-X5403 Gigabit Ethernet switching module
- description 4-28 to 4-31
- GBICs 4-28
- specifications A -7
- using a mode-conditioning patch cord 4-29
- WS-X5410 Gigabit EtherChannel switching module
- backplane assignment restrictions 4-33
- description 4-31 to 4-35
- GBICs 4-32
- specifications A -7
- using a mode-conditioning patch cord 4-33
Posted: Mon Sep 25 10:41:08 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.