This appendix lists the specifications for the Catalyst 5000 family modules and consists of these sections:
This section provides specifications for the Ethernet, Fast Ethernet, Gigabit Ethernet, ATM, FDDI/CDDI, ATM, network analysis, and the Route Switch Module (RSM) used in Catalyst 5000 family switches. In addition, this section provides the optical specifications for the Catalyst 5000 family switching modules.
Catalyst 5000 family modules, when installed in a system, comply with the standards listed in Table A-1.
.
Specification | Description |
---|---|
Compliance: | CE Marking |
| UL1 1950, CSA2-C22.2 No. 950, EN3 60950, IEC4 950, TS5 001, AS/NZS6 3260 |
| FCC8 Part 15 Class A (CFR 47 , Part 15), CISPR 22 Class A, EN 55022 Class A, VCCI9 Class A, and AS/NZS 3548 Class A with UTP10 cables, EN 55022 Class B, CISPR 22 Class B, VCCI Class B, and AS/NZS 3590, Class B with FTP11 cables |
| Net 1, Net 2, Net 3, Net 513 |
The ATM dual PHY DS3 module (WS-X5166) meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:
Applicant name: | Nihon Cisco Systems |
Model number: | WS-X5166 |
Approval number: | N98-N316-0 |
Date of approval: | March 18, 1998 |
The FDDI single-mode fiber module (WS-X5104) meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:
Applicant name: | Nihon Cisco Systems |
Model number: | WS-X5104 |
Approval number: | N98-3003-0 |
Date of approval: | June 10, 1998 |
Table A-2 describes the specifications of the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | 5.7 lb (2.53 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | 10BaseT (WS-X5020): RJ-21, female, telco |
RAM buffer memory | 192 KB per group |
Maximum station-to-station cabling distance | 10BaseT Ethernet: Categories 3-5 UTP1: 328 feet (100 meters) |
Frame Processing | Transparent Bridging (IEEE 802.1d) |
Network Management | Cisco Discovery Protocol, Ethernet MIB3 (RFC 1398), Interface Table (RFC 1573), Bridge MIB (RFC 1493), Ethernet Repeater MIB (RFC 1516), RMON4 MIB (RFC 1757), Cisco Workgroup MIB, and Cisco VTP5 |
1UTP=unshielded twisted-pair 2FTP=foil twisted-pair 3MIB=Management Information Base 4RMON=Remote Monitoring 5VTP=VLAN Trunk Protocol |
Table A-3 describes the specifications for the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
| 2.36 x 15.51 x 16.34 in. (60 x 394 x 415 mm) (WS-X5014 only) |
Weight | Minimum: 3 lb (1.36 kg) |
| Maximum: 5 lb (2.27 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | 10BaseT: RJ-21 (telco) and RJ-45 |
| 10BaseFL: ST and MT-RJ |
| 10/100BaseTX and 100BaseTX: RJ-45 and RJ-21 (telco) |
| 100BaseFX, MMF and SMF: SC and MT-RJ |
Maximum station-to-station cabling distance |
|
328 feet (100 meters), half- or full-duplex | |
| 1.2 miles (2 kilometers), half- or full-duplex |
| 328 feet (100 meters), half- or full-duplex |
| 1312 feet (400 meters), half-duplex |
| 1312 feet (400 meters), half-duplex |
Frame Processing | Transparent Bridging (802.1d) |
Network Management | Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB5 (RFC 1493), Cisco Workgroup MIB, and Cisco VTP6 |
1UTP=unshielded twisted-pair 2FTP=foil twisted-pair 362.5/125-micron multimode fiber-optic cable 48/125-micron single-mode fiber-optic cable 5MIB=Management Information Base 6VTP=VLAN Trunk Protocol |
Table A-4 describes the specifications for the following modules:
The WS-X5403 and WS-X5410 modules use Gigabit Interface Converters (GBICs), which are hot-swappable input/output devices that plug into a Gigabit Ethernet module and link the module with the fiber-optic network. GBICs are available in the following styles: 1000BaseSX (WS-G5484), 1000BaseLX/LH (WS-G5486), and 1000BaseZX (WS-G5487).
Specifications | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) (WS-X5403) |
| 2.36 x 15.51 x 16.34 in. (60 x 394 x 415 mm) (WS-X5410) |
Weight | Minimum: 3 lb (1.36 kg) |
| Maximum: 5 lb (2.27 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | SC |
Maximum station-to-station cabling distance |
|
1000BaseSX GBIC | 62.5-micron MMF: 902 feet (275 meters) 50-micron MMF: 1804 feet (550 meters) |
62.5-micron MMF: 1804 feet (550 meters) 50-micron MMF: 1804 feet (550 meters) 9/10-micron SMF: 6.2 miles (10 kilometers) | |
1000BaseZX GBIC | 9/10-micron SMF: 43.5 miles (70 kilometers) 8-micron dispersion-shifted SMF: 62.1 miles (100 kilometers) |
Frame Processing | Transparent Bridging (802.1d) |
Network Management | Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB4 (RFC 1493), Cisco Workgroup MIB, and Cisco VTP5 |
Table A-5 describes the specifications for the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
| Maximum: 5 lb (2.27 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | Multimode fiber-optic: MIC1 |
RAM buffer memory | 192 KB per interface |
Maximum station-to-station cabling distance | Category 5 UTP: 328 feet (100 meters) |
| 1.2 miles (2 kilometers) |
| 18 miles (30 kilometers) |
Frame Processing | Fragmentation (RFC 791), Translation (802.1h, 802.li), APaRT4 |
Network Management | Cisco Discovery Protocol, SNMP5 MIB6 II (RFC 1213), FDDI7 MIB (RFC 1512), Interface Extensions MIB (RFC 1573), 802.1D Spanning-Tree MIB, Bridging MIB (RFC 1493), FDDI SMT8 7.3, Cisco Workgroup MIB, CiscoView application |
Table A-6 describes the specifications for the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 inches (30 x 394 x 415 millimeters) |
Weight | Minimum: 3 lb (1.36 kg) |
Maximum: 5 lb (2.27 kg) | |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | MMF/SMF: SC: |
| Category 5 UTP: RJ-45 |
Memory: |
|
| 192 KB per interface |
| 4 MB |
| 16 MB |
| 512 KB |
| 128 KB |
Maximum station-to-station cabling distance |
|
| 1.2 miles (2 kilometers) |
| 6.2 miles (10 kilometers) |
| 328 feet (100 meters) |
Frame-to-cell conversion | AAL45, 4096 virtual circuits, 255 concurrent reassembly |
Indicators: |
|
| Green (operational) |
| Green (operational) |
| Green flashing (receive activity) |
| Green flashing (transmit activity) |
ATM standards | RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); ATM Forum LANE8 v1.0 LEC9, LECS10, LES11, BUS12; UNI13 3.0/3.1, Q.2931 signaling protocols; ILMI14 |
Network management | Cisco Discovery Protocol; SNMP15 MIB16 II (RFC 1213); AToM MIB (RFC 1695); LEC MIB (ATM Forum LANE v1.0); Cisco Workgroup Stack MIB; Cisco VLAN Trunk Protocol MIB; Cisco LECS; LES/BUS MIB; ILMI MIB |
Table A-7 describes the specifications for the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
Maximum: 5 lb (2.27 kg) | |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | MMF: SC |
| SMF: SC |
| Diagnostics port: RJ-451 |
Memory: |
|
| 512 KB |
| 4 or 8 MB |
| 16 or 32 MB |
| 512 KB |
| 512 KB |
OC-3 (MMF) optical specifications | Transmitter output power: -19 to -14 dBm |
OC-3 (SMF) optical specifications | Transmitter output power: -14 to -8 dBm |
OC-12 (MMF) optical specifications | Transmitter output power: -19 to -14 dBm |
OC-12 (SMF) optical specifications | Transmitter output power: -15 to -8 dBm |
Frame-to-cell conversion | AAL55, 4096 virtual circuits, 255 concurrent reassembly |
Indicators: |
|
| The switch performs a series of self-tests and diagnostic tests. |
| When a port is transmitting a packet, the LED is green; otherwise, it is off. |
| When a port is receiving a packet, the LED is green; otherwise it is off. |
| Status of the link integrity of an ATM port. If the integrity is good, the LED is green. If the link integrity is bad, the LED is off. |
| When green, the port is active. If the LED is off, the port is the standby port. |
| When green, the LED indicates that a signal is being received on the optical port. |
Network management | Cisco Discovery Protocol; SNMP6 MIB7 II (RFC 1213); AToM MIB (RFC 1695); LEC8 MIB (ATM Forum LANE9 v1.0); Cisco Workgroup Stack MIB; VTP10 MIB; Cisco LECS11; LES12/BUS13 MIB; ILMI14 MIB |
ATM standards | RFC 1483 LLC15 SNAP16 Bridging Encapsulation (PVC17); ATM Forum LANE v1.0 LEC, LECS, LES, BUS; UNI18 3.0/3.1, Q.2931 signaling protocols; ILMI; MPOA19 |
Table A-8 lists the ATM Dual PHY DS3 Module (WS-X5166) specifications.
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
Maximum: 5 lb (2.27 kg) | |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Cable | Coaxial (75-ohm RG-59) |
Connectors | BNC (bayonet style, twist lock) |
Memory: |
|
| 192 KB per interface |
| 4 MB |
| 16 MB |
| 512 KB |
| 128 KB |
Maximum station-to-station cabling distance | Coaxial cable (DS3): 450 feet (137 meters) |
Frame-to-cell conversion | AAL5, 4096 virtual circuits, 255 concurrent reassembly |
Data Rate | 44,736 Mbps |
Line Encoding | B3ZS |
Framing | C-bit parity, optionally PLCP4 with M23, otherwise ADM (ATM Framing) |
Timing | Primary and secondary 8-kHz reference from internal (default) or network |
Loopbacks | Transmit and receive |
Impedance | 75 ohms nominal |
Indicators: |
|
| Green (operational) |
| Green (operational) |
| Green flashing (receive activity) |
| Green flashing (transmit activity) |
ATM standards | RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); UNI8 3.0/3.1, Q.2931 signaling protocols; ILMI9 |
Network management | Cisco Discovery Protocol; SNMP10 MIB11 II (RFC 1213); AToM MIB (RFC 1695); Cisco Workgroup Stack MIB; Cisco VTP12 MIB; ILMI MIB |
Table A-9 describes the specifications for the following modules:
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | 3.9 lb (1.45 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | 16 RJ-45 IEEE 802.5 Token Ring (UTP1/FTP2) (Token Ring module) |
Frame Processing | Source-route, source-route transparent, source-route switching |
Network Management | SNMP4 |
1UTP=unshielded twisted-pair 2FTP=foil twisted-pair 3MMF=multimode fiber 4SNMP = Simple Network Management Protocol |
Table A-10 lists the Route Switch Module (WS-X5302) specifications.
Specification | Description |
---|---|
Processors | 2 R4700 RISC1 processors running at external clock speeds of 50 MHz and internal clock speeds of 100 MHz |
Memory: |
|
| 32-MB (minimum), 64-MB, or 128-MB main and shared memory; available in 8-MB (8 x 4), 16-MB (16 x 2 or 16 x 4), or 32-MB (32 x 4) SIMMs3 |
| 128-KB nonvolatile EPROM5 for the system configuration file |
| 8-MB or 16-MB onboard Flash SIMMs for the IOS images |
| 16-MB or 20-MB PC card for the IOS images; the RSM has two Flash PC card slots providing a maximum of 40-MB Flash card memory |
| 256-KB EPROM for the ROM monitor program |
| 1 serial console port |
Table A-11 lists the Network Analysis Module (WS-X5380) specifications.
Specification | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Table A-12 describes the specifications for the following modules:
Specifications | Description |
---|---|
Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
Environmental Conditions: |
|
| 32 to 104° F (0 to 40° C) |
| -40 to 167° F (-40 to 75° C) |
| 10 to 90%, noncondensing |
Connectors | Layer 3-Fabric Integration Module---8 SC-type connectors |
Table A-13 lists the optical specifications for the Catalyst 5000 family switching modules.
Specification | Multimode1 | Single-Mode2 | Single-Mode3 |
---|---|---|---|
Transmitter output power | -19 to -14 dBm4 | -14 to -8 dBm | -4.0 to -7.0 dBm |
Receiver sensitivity | -32.5 to -14 dBm | 32.5 to -8 dBm | N/A |
Wavelength | 850 to 1360 nm | 1261 to 1360 nm | 1261 to 1360 nm |
Optical source | LED | Laser | Laser |
Maximum span | 1.2 miles (2 km) | 6.2 miles (10 km) | 18 miles (30 km) |
This section lists and defines the output signals for ports on the supervisor engine module, switching modules, and the RSM. This section also defines the cable pinouts for certain interface cable connectors that connect modules to the external network. Pins that are not specifically listed are not connected.
The following is a list of the signal summaries contained in this appendix:
Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, see Chapter 2, "Installation Preparation."
Table A-14 lists the output signals for the 40-pin media-independent interface (MII) Fast Ethernet connector on the supervisor engine module.
Pin | Signal |
---|---|
1, 20, 21, 40 | +5V |
2 | MDIO |
3 | MDC |
4 | RxD<3> |
5 | RxD<2> |
6 | RxD<1> |
7 | RxD<0> |
8 | Rx_DV |
9 | Rx_Clk |
10 | Rx_Er |
11 | Tx_Er |
12 | Tx_Clk |
13 | Tx_En |
14 | TxD<0> |
15 | TxD<1> |
16 | TxD<2> |
17 | TxD<3> |
18 | Col |
19 | CRS |
22 through 39 | Common |
Table A-15 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module. The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.
Pin | Signal | Description |
---|---|---|
1 | RxD (+) | Receive Data (+) |
2 | RxD (-) | Receive Data (-) |
3 | TxD (+) | Transmit Data (+) |
4 | NC | No Connection |
5 | NC | No Connection |
6 | TxD (-) | Transmit Data (-) |
7 | NC | No Connection |
8 | NC | No Connection |
Table A-16 lists the output signals for the RJ-21 telco connector on the Ethernet switching module (10BaseT 24 port) and the Ethernet switching module (10BaseT 48 port). The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.
Ethernet Port No. | Connector Pin No. | Signal | Connector Pin No. | Signal |
---|---|---|---|---|
1 | 1 | RxD (-) | 26 | RxD (+) |
2 | 3 | RxD (-) | 28 | RxD (+) |
3 | 5 | RxD (-) | 30 | RxD (+) |
4 | 7 | RxD (-) | 32 | RxD (+) |
5 | 9 | RxD (-) | 34 | RxD (+) |
6 | 11 | RxD (-) | 36 | RxD (+) |
7 | 13 | RxD (-) | 38 | RxD (+) |
8 | 15 | RxD (-) | 40 | RxD (+) |
9 | 17 | RxD (-) | 42 | RxD (+) |
10 | 19 | RxD (-) | 44 | RxD (+) |
11 | 21 | RxD (-) | 46 | RxD (+) |
12 | 23 | RxD (-) | 48 | RxD (+) |
gnd | 25 | gnd | 50 | gnd |
Table A-17 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP). The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.
Pin | Signal | Description |
---|---|---|
1 | TxD (+) | Transmit Data + |
2 | TxD (-) | Transmit Data - |
3 | NC | No Connection |
4 | NC | No Connection |
5 | NC | No Connection |
6 | NC | No Connection |
7 | RxD (+) | Receive Data + |
8 | RxD (-) | Receive Data - |
Table A-18 lists the output signal descriptions for the mini-DIN connector on the optical bypass switch that is available on FDDI modules. A mini-DIN-to-DIN adapter cable connector allows connection to an optical bypass switch that uses a DIN connector.
Pin | Description |
---|---|
1 | +5V to secondary switch |
2 | +5V to primary switch |
3 | Ground to enable primary switch |
4 | Ground to enable secondary switch |
5 | Sense circuit---1 kohm to +5V |
6 | Ground---Sense circuit return |
Table A-19 lists the pinouts of straight-through cable connectors used with CDDI modules.
Pin | Signal | Signal | Pin |
---|---|---|---|
1 | TxD | RxD | 1 |
2 | TxD | RxD | 2 |
3 | Not Connected | Not Connected | 3 |
4 | Not Connected | Not Connected | 4 |
5 | Not Connected | Not Connected | 5 |
6 | Not Connected | Not Connected | 6 |
7 | RxD | TxD | 7 |
8 | RxD | TxD | 8 |
Table A-20 lists the pinouts for cross-connect connectors used with CDDI modules.
Caution Table A-20 lists the pinouts for the cross-connect cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules. |
Pin | Signal | Signal | Pin |
---|---|---|---|
1 | RxD | TxD | 8 |
2 | RxD | TxD | 7 |
3 | Not Connected | Not Connected | 6 |
4 | Not Connected | Not Connected | 5 |
5 | Not Connected | Not Connected | 4 |
6 | Not Connected | Not Connected | 3 |
7 | TxD | RxD | 2 |
8 | TxD | RxD | 1 |
For information on the RSM console and auxiliary port pinouts, refer to the Catalyst 5000 Family Route Switch Module Installation and Configuration Note.
Posted: Mon Feb 21 15:03:38 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.