Specifications

This appendix lists the specifications for the Catalyst 5000 family modules and consists of these sections:


Note For specifications on Catalyst 5000 family switch chassis, refer to the Catalyst 5000 Family Installation Guide. For specifications on supervisor engines, refer to the Catalyst 5000 Family Supervisor Engine Installation Guide.

Module Specifications

This section provides specifications for the Ethernet, Fast Ethernet, Gigabit Ethernet, ATM, FDDI/CDDI, ATM, network analysis, and the Route Switch Module (RSM) used in Catalyst 5000 family switches. In addition, this section provides the optical specifications for the Catalyst 5000 family switching modules.

Standards Compliance

Catalyst 5000 family modules, when installed in a system, comply with the standards listed in Table A-1.

.


Table A-1: Standards Compliance
Specification Description

Compliance:

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN3 60950, IEC4 950, TS5 001, AS/NZS6 3260

EMI7

FCC8 Part 15 Class A (CFR 47 , Part 15), CISPR 22 Class A, EN 55022 Class A,  VCCI9 Class A, and AS/NZS 3548 Class A with UTP10 cables, EN 55022 Class B, CISPR 22 Class B, VCCI Class B, and AS/NZS 3590, Class B with FTP11 cables

Network homologation12

Net 1, Net 2, Net 3, Net 513

1UL = Underwriters Laboratories
2CSA = Canadian Standards Association
3EN = Europäische Norm
4IEC = International Electrotechnical Commission
5TS = Technical Standard
6AS/NZS = Australian/New Zealand Standard
7EMI = electromagnetic interference
8FCC = Federal Communications Commission
9VCCI = Voluntary Control Council for Information Technology Equipment
10UTP = unshielded twisted-pair
11FTP = foil twisted-pair
12Applies to the Route Switch Module
13For more information on network homologation standards, see the Regulatory Compliance and Safety Information for Cisco 7000 Series Routers, Regulatory Compliance and Safety Information for Cisco 7200 Series Routers, and Regulatory Compliance and Safety Information for Cisco 7500 Series Routers publications

The ATM dual PHY DS3 module (WS-X5166) meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:

Applicant name:

Nihon Cisco Systems

Model number:

WS-X5166

Approval number:

N98-N316-0

Date of approval:

March 18, 1998

The FDDI single-mode fiber module (WS-X5104) meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:

Applicant name:

Nihon Cisco Systems

Model number:

WS-X5104

Approval number:

N98-3003-0

Date of approval:

June 10, 1998

Group Switching Ethernet and Fast Ethernet Modules

Table A-2 describes the specifications of the following modules:


Table A-2: Group Switching Ethernet, Group Switching Fast Ethernet, and Workgroup Fast Ethernet Switching Module Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

5.7 lb (2.53 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

10BaseT (WS-X5020): RJ-21, female, telco
100BaseTX (WS-X5223 and WS-X5224): RJ-45

RAM buffer memory

192 KB per group

Maximum station-to-station cabling distance

10BaseT Ethernet: Categories 3-5 UTP1: 328 feet (100 meters)
100-ohm FTP2: 328 feet (100 meters)

Frame Processing

Transparent Bridging (IEEE 802.1d)

Network Management

Cisco Discovery Protocol, Ethernet MIB3 (RFC 1398), Interface Table (RFC 1573), Bridge MIB (RFC 1493), Ethernet Repeater MIB (RFC 1516), RMON4 MIB (RFC 1757), Cisco Workgroup MIB, and Cisco VTP5

1UTP=unshielded twisted-pair
2FTP=foil twisted-pair
3MIB=Management Information Base
4RMON=Remote Monitoring
5VTP=VLAN Trunk Protocol

Ethernet and Fast Ethernet Switching Modules

Table A-3 describes the specifications for the following modules:


Table A-3: Ethernet and Fast Ethernet Switching Module Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

2.36 x 15.51 x 16.34 in. (60 x 394 x 415 mm) (WS-X5014 only)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

10BaseT: RJ-21 (telco) and RJ-45

10BaseFL: ST and MT-RJ

10/100BaseTX and 100BaseTX: RJ-45 and RJ-21 (telco)

100BaseFX, MMF and SMF: SC and MT-RJ

Maximum station-to-station cabling distance

10-Mbps
(Categories 3-5 UTP1 and 100-ohm FTP2)

328 feet (100 meters), half- or full-duplex

10-Mbps
(MMF3)

1.2 miles (2 kilometers), half- or full-duplex

10/100-Mbps
(Categories 3-5 UTP and 100-ohm FTP)

328 feet (100 meters), half- or full-duplex

10/100-Mbps
(MMF)

1312 feet (400 meters), half-duplex
1.2 miles (2 kilometers), full-duplex

100-Mbps
(SMF4)

1312 feet (400 meters), half-duplex
6.2 miles (10 kilometers), full-duplex

Frame Processing

Transparent Bridging (802.1d)

Network Management

Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB5 (RFC 1493), Cisco Workgroup MIB, and Cisco VTP6

1UTP=unshielded twisted-pair
2FTP=foil twisted-pair
362.5/125-micron multimode fiber-optic cable
48/125-micron single-mode fiber-optic cable
5MIB=Management Information Base
6VTP=VLAN Trunk Protocol

Gigabit Ethernet Switching Modules

Table A-4 describes the specifications for the following modules:

The WS-X5403 and WS-X5410 modules use Gigabit Interface Converters (GBICs), which are hot-swappable input/output devices that plug into a Gigabit Ethernet module and link the module with the fiber-optic network. GBICs are available in the following styles: 1000BaseSX (WS-G5484), 1000BaseLX/LH (WS-G5486), and 1000BaseZX (WS-G5487).


Table A-4: Gigabit Ethernet Switching Modules
Specifications
Specifications Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) (WS-X5403)

2.36 x 15.51 x 16.34 in. (60 x 394 x 415 mm) (WS-X5410)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

SC

Maximum station-to-station cabling distance

1000BaseSX GBIC
(850 nm laser device over MMF1)

62.5-micron MMF: 902 feet (275 meters)

50-micron MMF: 1804 feet (550 meters)

1000BaseLX/LH GBIC
(1300-nm laser device over MMF2/SMF3)

62.5-micron MMF: 1804 feet (550 meters)

50-micron MMF: 1804 feet (550 meters)

9/10-micron SMF: 6.2 miles (10 kilometers)

1000BaseZX GBIC
(1550-nm laser device over SMF)

9/10-micron SMF: 43.5 miles (70 kilometers)

8-micron dispersion-shifted SMF: 62.1 miles (100 kilometers)

Frame Processing

Transparent Bridging (802.1d)

Network Management

Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB4 (RFC 1493), Cisco Workgroup MIB, and Cisco VTP5

1MMF=multimode fiber
2Mode-conditioning patch cord (CAB-GELX-625 or equivalent) is required. Using an ordinary patch cord with MMF, 1000BaseLX/LH GBICs, and a short link distance (less than 50 m) can cause transceiver saturation resulting in an elevated bit error rate (BER). In addition, when using the LX/LH GBIC with 62.5-micron diameter MMF, you must install a mode-conditioning patch cord between the GBIC and the MMF cable on both the transmit and receive ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 ft (300 m).
3SMF=single-mode fiber
4MIB=Management Information Base
5VTP=VLAN Trunk Protocol


Note The mode-conditioning
patch cord (CAB-GELX-625 or equivalent) is required to comply with IEEE standards. The IEEE found that link distances could not be met with certain types of fiber-optic cable cores. The solution is to launch light from the laser at a precise offset from the center by using the mode-conditioning patch cord. At the output of the patch cord, the LX/LH GBIC is compliant with the IEEE 802.3z standard for 1000BaseLX.

FDDI and CDDI Modules

Table A-5 describes the specifications for the following modules:


Table A-5: FDDI and CDDI Modules Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

Multimode fiber-optic: MIC1
Single-mode fiber-optic: ST2
Category 5 UTP3: RJ-45

RAM buffer memory

192 KB per interface

Maximum station-to-station cabling distance

Category 5 UTP: 328 feet (100 meters)

MMF, 62.5/125-micron

1.2 miles (2 kilometers)

SMF

18 miles (30 kilometers)

Frame Processing

Fragmentation (RFC 791), Translation (802.1h, 802.li), APaRT4

Network Management

Cisco Discovery Protocol, SNMP5 MIB6 II (RFC 1213), FDDI7 MIB (RFC 1512), Interface Extensions MIB (RFC 1573), 802.1D Spanning-Tree MIB, Bridging MIB (RFC 1493), FDDI SMT8 7.3, Cisco Workgroup MIB, CiscoView application

1MIC=media interface connector
2ST=straight through
3UTP=unshielded twisted-pair
4APaRT=automated packet recognition/translation
5SNMP=Simple Network Management Protocol
6MIB=Management Information Base
7FDDI=Fiber Distributed Data Interface
8SMT=station management

ATM LANE Modules

Table A-6 describes the specifications for the following modules:


Table A-6: ATM LANE Module Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 inches (30 x 394 x 415 millimeters)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

MMF/SMF: SC:

Category 5 UTP: RJ-45

Memory:

RAM buffer

192 KB per interface

Flash

4 MB

DRAM1

16 MB

EPROM2

512 KB

NVRAM3

128 KB

Maximum station-to-station cabling distance

MMF

1.2 miles (2 kilometers)

SMF

6.2 miles (10 kilometers)

Category 5 UTP

328 feet (100 meters)

Frame-to-cell conversion

AAL45, 4096 virtual circuits, 255 concurrent reassembly

Indicators:

Module status

Green (operational)

Port active status

Green (operational)

RX

Green flashing (receive activity)

TX

Green flashing (transmit activity)

ATM standards

RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); ATM Forum LANE8 v1.0 LEC9, LECS10, LES11, BUS12; UNI13 3.0/3.1, Q.2931 signaling protocols; ILMI14

Network management

Cisco Discovery Protocol; SNMP15 MIB16 II (RFC 1213); AToM MIB (RFC 1695); LEC MIB (ATM Forum LANE v1.0); Cisco Workgroup Stack MIB; Cisco VLAN Trunk Protocol MIB; Cisco LECS; LES/BUS MIB; ILMI MIB

1DRAM=dynamic random-access memory
2EPROM= erasable programmable read-only memory
3NVRAM=nonvolatile random-access memory
4AAL=ATM adaptation layer
5LLC=Logical Link Control
6SNAP=Subnetwork Access Protocol
7PVC=permanent virtual connection
8LANE=LAN Emulation
9LEC=LAN Emulation Client
10LECS=LAN Emulation Configuration Server
11LES=LAN Emulation Server
12BUS=broadcast and unknown server
13UNI=User-Network Interface
14ILMI=Integrated Local Management Interface
15SNMP=Simple Network Management Protocol
16MIB=Management Information Base

ATM Dual PHY OC-3 and OC-12 LANE/MPOA Modules

Table A-7 describes the specifications for the following modules:


Table A-7: ATM Dual PHY OC-3 and OC-12 LANE/MPOA Module
Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

MMF: SC

SMF: SC

Diagnostics port: RJ-451

Memory:

RAM buffer

512 KB

Flash

4 or 8 MB

DRAM2

16 or 32 MB

EPROM3

512 KB

NVRAM4

512 KB

OC-3 (MMF) optical specifications

Transmitter output power: -19 to -14 dBm
Receiver sensitivity: -32.5 to -14 dBm
Wavelength: 1270 to 1380 nm
Optical source: LED
Maximum station-to-station cabling distance: 1.2 miles (2 kilometers)

OC-3 (SMF) optical specifications

Transmitter output power: -14 to -8 dBm
Receiver sensitivity: -32.5 to -8 dBm
Wavelength: 1261 to 1360 nm
Optical source: laser
Maximum station-to-station cabling distance: 6.2 miles (10 kilometers)

OC-12 (MMF) optical specifications

Transmitter output power: -19 to -14 dBm
Receiver sensitivity: -28 to -8 dBm
Wavelength: 1300 nm
Optical source: laser
Maximum station-to-station cabling distance: 9.3 miles (15 kilometers)

OC-12 (SMF) optical specifications

Transmitter output power: -15 to -8 dBm
Receiver sensitivity: -32.5 to -14 dBm
Wavelength: 1270 to 1380 nm
Optical source: LED
Maximum station-to-station cabling distance: 1.2 miles (2 kilometers)

Frame-to-cell conversion

AAL55, 4096 virtual circuits, 255 concurrent reassembly

Indicators:

Module status

The switch performs a series of self-tests and diagnostic tests.
If all the tests pass, the LED is green.

TX (Transmit)

When a port is transmitting a packet, the LED is green; otherwise, it is off.

RX (Receive)

When a port is receiving a packet, the LED is green; otherwise it is off.

Link

Status of the link integrity of an ATM port. If the integrity is good, the LED is green. If the link integrity is bad, the LED is off.

Active

When green, the port is active. If the LED is off, the port is the standby port.

Signal

When green, the LED indicates that a signal is being received on the optical port.

Network management

Cisco Discovery Protocol; SNMP6 MIB7 II (RFC 1213); AToM MIB (RFC 1695); LEC8 MIB (ATM Forum LANE9 v1.0); Cisco Workgroup Stack MIB; VTP10 MIB; Cisco LECS11; LES12/BUS13 MIB; ILMI14 MIB

ATM standards

RFC 1483 LLC15 SNAP16 Bridging Encapsulation (PVC17); ATM Forum LANE v1.0 LEC, LECS, LES, BUS; UNI18 3.0/3.1, Q.2931 signaling protocols; ILMI; MPOA19

1The diagnostics port is for manufacturing use only
2DRAM=dynamic random-access memory
3EPROM= erasable programmable read-only memory
4NVRAM=nonvolatile random-access memory
5AAL=ATM adaptation layer
6SNMP=Simple Network Management Protocol
7MIB=Management Information Base
8LEC=LAN Emulation Client
9LANE=LAN Emulation
10VTP=VLAN Trunk Protocol
11LECS=LAN Emulation Configuration Server
12LES=LAN Emulation Server
13BUS=broadcast and unknown server
14ILMI=Integrated Local Management Interface
15LLC=Logical Link Control
16SNAP=Subnetwork Access Protocol
17PVC=permanent virtual connection
18UNI=User-Network Interface
19MPOA=Multiprotocol over ATM

ATM Dual PHY DS3 Module

Table A-8 lists the ATM Dual PHY DS3 Module (WS-X5166) specifications.


Table A-8: ATM Dual PHY DS3 Module Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Cable

Coaxial (75-ohm RG-59)

Connectors

BNC (bayonet style, twist lock)

Memory:

RAM buffer

192 KB per interface

Flash

4 MB

DRAM1

16 MB

EPROM2

512 KB

NVRAM3

128 KB

Maximum station-to-station cabling distance

Coaxial cable (DS3): 450 feet (137 meters)

Frame-to-cell conversion

AAL5, 4096 virtual circuits, 255 concurrent reassembly

Data Rate

44,736 Mbps

Line Encoding

B3ZS

Framing

C-bit parity, optionally PLCP4 with M23, otherwise ADM (ATM Framing)

Timing

Primary and secondary 8-kHz reference from internal (default) or network

Loopbacks

Transmit and receive

Impedance

75 ohms nominal

Indicators:

Module status

Green (operational)

Port active status

Green (operational)

RX

Green flashing (receive activity)

TX

Green flashing (transmit activity)

ATM standards

RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); UNI8 3.0/3.1, Q.2931 signaling protocols; ILMI9

Network management

Cisco Discovery Protocol; SNMP10 MIB11 II (RFC 1213); AToM MIB (RFC 1695); Cisco Workgroup Stack MIB; Cisco VTP12 MIB; ILMI MIB

1DRAM=dynamic random-access memory
2EPROM=erasable programmable read-only memory
3NVRAM=nonvolatile RAM
4PLCP = physical layer convergence procedure
5LLC=Logical Link Control
6SNAP=Subnet Access Protocol
7PVC=permanent virtual connection
8User-Network Interface
9ILMI=Integrated Local Managment Interface
10SNMP=Simple Network Management Protocol
11MIB=Management Information Base
12VTP=VLAN Trunk Protocol

Token Ring Modules

Table A-9 describes the specifications for the following modules:


Table A-9: Token Ring Modules Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

3.9 lb (1.45 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

16 RJ-45 IEEE 802.5 Token Ring (UTP1/FTP2) (Token Ring module)
16 Volition VF-45 MMF3 connectors (fiber Token Ring module)

Frame Processing

Source-route, source-route transparent, source-route switching

Network Management

SNMP4

1UTP=unshielded twisted-pair
2FTP=foil twisted-pair
3MMF=multimode fiber
4SNMP = Simple Network Management Protocol

Route Switch Module

Table A-10 lists the Route Switch Module (WS-X5302) specifications.


Table A-10:
Route Switch Module Specifications
Specification Description

Processors

2 R4700 RISC1 processors running at external clock speeds of 50 MHz and internal clock speeds of 100 MHz

Memory:

DRAM2

32-MB (minimum), 64-MB, or 128-MB main and shared memory; available in 8-MB (8 x 4), 16-MB (16 x 2 or 16 x 4), or 32-MB (32 x 4) SIMMs3

NVRAM4

128-KB nonvolatile EPROM5 for the system configuration file

Flash SIMM

8-MB or 16-MB onboard Flash SIMMs for the IOS images

Flash Card

16-MB or 20-MB PC card for the IOS images; the RSM has two Flash PC card slots providing a maximum of 40-MB Flash card memory

Boot ROM

256-KB EPROM for the ROM monitor program

Interfaces

1 serial console port
1 serial auxiliary port
Backplane interface: 2 SAGE ASICs6

1RISC = Reduced Instruction Set Computing
2DRAM = dynamic random-access memory
3SIMMs=single in-line memory modules
4NVRAM=nonvolatile RAM
5EPROM=erasable programmable read-only memory
6ASICs=application-specific integrated circuits

Network Analysis Module

Table A-11 lists the Network Analysis Module (WS-X5380) specifications.


Table A-11: Network Analysis Module Specifications
Specification Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Fabric Integration Modules

Table A-12 describes the specifications for the following modules:


Table A-12: Fabric Integration Modules Specifications
Specifications Description

Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Connectors

Layer 3-Fabric Integration Module---8 SC-type connectors
ATM-Fabric Integration Module---1 SC-type connector

Optical Specifications

Table A-13 lists the optical specifications for the Catalyst 5000 family switching modules.


Table A-13: Optical Specifications
Specification Multimode1 Single-Mode2 Single-Mode3

Transmitter output power

-19 to -14 dBm4

-14 to -8 dBm

-4.0 to -7.0 dBm

Receiver sensitivity

-32.5 to -14 dBm

32.5 to -8 dBm

N/A

Wavelength

850 to 1360 nm

1261 to 1360 nm

1261 to 1360 nm

Optical source

LED

Laser

Laser

Maximum span

1.2 miles (2 km)

6.2 miles (10 km)

18 miles (30 km)

1Applies to modules WS-X5005, WS-X5011, WS-X5155, WS-X5114, WS-X5101, WS-X5201, WS-X5158, WS-X5161, WS-X5305, WS-X5165, WS-X5201R, and WS-X5167.
2Applies to modules WS-X5006, WS-X5157, WS-X5114, WS-X5154, WS-X5162, and WS-X5168.
3Applies to module WS-X5104.
4dBm = decibels per milliwatt

Connector Output Signal and Cable Pinout Specifications

This section lists and defines the output signals for ports on the supervisor engine module, switching modules, and the RSM. This section also defines the cable pinouts for certain interface cable connectors that connect modules to the external network. Pins that are not specifically listed are not connected.

The following is a list of the signal summaries contained in this appendix:

Fast Ethernet MII Connector Output Signals

Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, see Chapter 2, "Installation Preparation."

Table A-14 lists the output signals for the 40-pin media-independent interface (MII) Fast Ethernet connector on the supervisor engine module.


Note Table A-14 lists the output signals from the MII connector on the supervisor engine module, not the pinouts of the cable connecting to the module.


Table A-14: Supervisor Engine Module 40-Pin MII Fast Ethernet Connector Output Signals
Pin Signal

1, 20, 21, 40

+5V

2

MDIO

3

MDC

4

RxD<3>

5

RxD<2>

6

RxD<1>

7

RxD<0>

8

Rx_DV

9

Rx_Clk

10

Rx_Er

11

Tx_Er

12

Tx_Clk

13

Tx_En

14

TxD<0>

15

TxD<1>

16

TxD<2>

17

TxD<3>

18

Col

19

CRS

22 through 39

Common

Fast Ethernet TX MDI X Port Output Signals

Table A-15 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module. The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.


Note 
Table A-15 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module, not the pinouts of the cable connecting to the modules.


Table A-15: Fast Ethernet 100BaseTX MDI X Port Output Signals
Pin Signal Description

1

RxD (+)

Receive Data (+)

2

RxD (-)

Receive Data (-)

3

TxD (+)

Transmit Data (+)

4

NC

No Connection

5

NC

No Connection

6

TxD (-)

Transmit Data (-)

7

NC

No Connection

8

NC

No Connection

Ethernet 10BaseT RJ-21 Telco Connector Output Signals

Table A-16 lists the output signals for the RJ-21 telco connector on the Ethernet switching module (10BaseT 24 port) and the Ethernet switching module (10BaseT 48 port). The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.


Note Table A-16 lists the output signals for the RJ-21 telco connector, not the pinouts of the cable connecting to the module.


Table A-16: Ethernet 10BaseT RJ-21 Telco Connector
Output Signals
Ethernet Port No. Connector Pin No. Signal Connector Pin No. Signal

1

1
2

RxD (-)
TxD (-)

26
27

RxD (+)
TxD (+)

2

3
4

RxD (-)
TxD (-)

28
29

RxD (+)
TxD (+)

3

5
6

RxD (-)
TxD (-)

30
31

RxD (+)
TxD (+)

4

7
8

RxD (-)
TxD (-)

32
33

RxD (+)
TxD (+)

5

9
10

RxD (-)
TxD (-)

34
35

RxD (+)
TxD (+)

6

11
12

RxD (-)
TxD (-)

36
37

RxD (+)
TxD (+)

7

13
14

RxD (-)
TxD (-)

38
39

RxD (+)
TxD (+)

8

15
16

RxD (-)
TxD (-)

40
41

RxD (+)
TxD (+)

9

17
18

RxD (-)
TxD (-)

42
43

RxD (+)
TxD (+)

10

19
20

RxD (-)
TxD (-)

44
45

RxD (+)
TxD (+)

11

21
22

RxD (-)
TxD (-)

46
47

RxD (+)
TxD (+)

12

23
24

RxD (-)
TxD (-)

48
49

RxD (+)
TxD (+)

gnd

25

gnd

50

gnd

ATM LANE Module (UTP) Connector Output Signals

Table A-17 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP). The receive and transmit signals are polarized. One pin of each signal pair carries the positive (+) signal, and the other pin carries the negative (-) signal.


Note Table A-17 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP), not the pinouts of the cable connecting to the module.


Table A-17: ATM LANE Module (UTP) RJ-45 Connector
Output Signals
Pin Signal Description

1

TxD (+)

Transmit Data +

2

TxD (-)

Transmit Data -

3

NC

No Connection

4

NC

No Connection

5

NC

No Connection

6

NC

No Connection

7

RxD (+)

Receive Data +

8

RxD (-)

Receive Data -

FDDI Optical Bypass Connector Output Signals

Table A-18 lists the output signal descriptions for the mini-DIN connector on the optical bypass switch that is available on FDDI modules. A mini-DIN-to-DIN adapter cable connector allows connection to an optical bypass switch that uses a DIN connector.


Note 
Table A-18 lists the output signals for the mini-DIN connector on the optical bypass switch, not the pinouts of the cable connecting to the optical bypass switch.


Table A-18: Optical Bypass Switch Mini-DIN Connector
Output Signals
Pin Description

1

+5V to secondary switch

2

+5V to primary switch

3

Ground to enable primary switch

4

Ground to enable secondary switch

5

Sense circuit---1 kohm to +5V

6

Ground---Sense circuit return

CDDI Transmit and Receive Connector Pinouts

Table A-19 lists the pinouts of straight-through cable connectors used with CDDI modules.


Note 
Table A-19 lists the pinouts for the straight-through cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules.


Table A-19: CDDI Straight-Through Connector Pinouts
Pin Signal Signal Pin

1

TxD

RxD

1

2

TxD

RxD

2

3

Not Connected

Not Connected

3

4

Not Connected

Not Connected

4

5

Not Connected

Not Connected

5

6

Not Connected

Not Connected

6

7

RxD

TxD

7

8

RxD

TxD

8

Table A-20 lists the pinouts for cross-connect connectors used with CDDI modules.

Caution Table A-20 lists the pinouts for the cross-connect cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules.


Table A-20: CDDI Cross-Connect Connector Pinouts
Pin Signal Signal Pin

1

RxD

TxD

8

2

RxD

TxD

7

3

Not Connected

Not Connected

6

4

Not Connected

Not Connected

5

5

Not Connected

Not Connected

4

6

Not Connected

Not Connected

3

7

TxD

RxD

2

8

TxD

RxD

1

RSM Console and Auxiliary Port Pinouts

For information on the RSM console and auxiliary port pinouts, refer to the Catalyst 5000 Family Route Switch Module Installation and Configuration Note.