cc/td/doc/product/ong/15400/r80docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Network Element Defaults

C.1  Network Element Defaults Description

C.2  ANSI Platform Defaults

C.2.1  ANSI Card Defaults

C.2.2  ANSI Node Default Settings

C.3  CTC Default Settings

C.4  ETSI Platform Defaults

C.4.1  ETSI Card Defaults

C.4.2  ETSI Node Default Settings


Network Element Defaults



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15454. It includes descriptions of card, node, and Cisco Transport Controller (CTC) default settings. To import, export, or edit the settings, see the "Maintain the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide. Cards supported by this platform that are not listed in this appendix are not supported by user-configurable NE defaults settings.


Note Unless otherwise specified, in this appendix "ONS 15454" refers to both ANSI (ONS 15454 SONET) and ETSI (ONS 15454 SDH) shelf assemblies.


C.1  Network Element Defaults Description

The NE defaults are preinstalled on each Cisco ONS 15454 TCC2 and TCC2P card. Cisco also ships a file named 15454-defaults.txt (ANSI shelves) or 15454SDH-defaults.txt (ETSI shelves) on the CTC software CD in case you want to import the defaults onto existing TCC2/TCC2P cards. The NE defaults include card-level, CTC, and node-level defaults.

Manual card provisioning overrides default settings. Manual changes are those made using the "Provision Transponder and Muxponder Cards" chapter or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide. If you use the CTC Defaults editor (on the node view Provisioning > Defaults tabs) or import a new defaults file, any changes to card or port settings that result only affect cards that are installed or preprovisioned after the defaults have changed.

Changes made manually to most node-level default settings override the current settings, whether default or provisioned. If you change node-level default settings, either by using the Defaults editor or by importing a new defaults file, the new defaults reprovision the node immediately for all settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1 revertive, Bidirectional Line Switched Ring [BLSR] or multiplex section-shared protection ring [MS-SPRing] reversion time, BLSR/MS-SPRing ring revertive, BLSR/MS-SPRing span reversion time, BLSR/MS-SPRing span revertive, y cable revertive or reversion time, splitter revertive or reversion time). Settings relating to protection apply to subsequent provisioning.


Note Changing some node-level provisioning through NE defaults can cause CTC disconnection or a reboot of the node in order for the provisioning to take effect. Before you change a default, check in the Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) and be prepared for the occurrence of any side effects listed for that default.


C.2  ANSI Platform Defaults

The following sections give the NE defaults for the ONS 15454 ANSI platform. To see defaults for the ONS 15454 ETSI platform, see the "ETSI Platform Defaults" section.

C.2.1  ANSI Card Defaults

The tables in this section list the default settings for each DWDM, Transponder (TXP), Muxponder (MXP), or Ethernet card. Cisco provides several types of user-configurable defaults for Cisco ONS 15454 DWDM, TXP, MXP, and Ethernet cards. Types of card defaults can be broadly grouped by function, as outlined in the following subsections. For information about individual card settings, refer to the "Provision Transponder and Muxponder Cards" chapter or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide.


Note The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual or the Cisco ONS 15454 SDH Reference Manual.


The following types of defaults are defined for DWDM, TXP, MXP, and Ethernet cards.

C.2.1.1  ANSI Configuration Defaults

Most card-level and port-level configuration defaults correspond to settings found in the CTC card-level Provisioning tabs.


Note The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OSCM, OSC-CSM, OPT-BST, OPT-BST-L, ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards. For information on how ALS card settings achieve network level optical safety, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."


Configuration defaults that are reachable from the CTC card-level Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab):

Line—(ADM-10G, GE_XP, 10GE_XP, TXP and MXP cards) Line-level configuration settings, including SONET, Wavelength Trunk, Trunk, Client, Distance Extension, and Enhanced FC/FICON ISL settings.


Note Some line configuration tabs, including Client, Distance Extension, and Enhanced FC/FICON ISL settings tabs, only appear in the card-level Provisioning > Line tab after a pluggable port module (PPM) is provisioned to a fibre channel payload type (port rate) for the particular card.


OTN—(ADM-10G, GE_XP, 10GE_XP, MXP-2.5G-10E, MXP-2_5G-10G, MXP-MR-10DME, TXP-MR-10E, TXP-MR-10G, TXP-MR-2.5G, and TXPP-MR-2.5G cards) Optical transport network (OTN) line configuration settings.

Card—(See listed settings for applicable cards)

Card mode—MXPP-MR-2.5G and MXP-MR-2.5G (ESCON, FC_GE, or MIXED), GE_XP (20GE MXP, 10GE MXP, or L2 over DWDM) , and 10GE_XP (10GE TXP or L2 over DWDM)

Port range-level mode settings—MXP-MR-10DME cards only

Termination mode—TXP-MR-10E, MXP-2.5G-10E, MXP-2.5G-10G, TXPP_MR_2.5G, TXP_MR_10G, and TXP_MR_2.5G cards

AIS squelch settings—TXP-MR-10E and MXP-2.5G-10E cards

ALS (card-level Maintenance > ALS tab)—(OSC-CSM, OSCM, OPT-BST, OPT-BST-L, ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards) ALS configuration defaults.


Note For further information about supported features on each card, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."


C.2.1.2  ANSI Threshold Defaults

Threshold default settings define the default cumulative values (thresholds) beyond which a threshold crossing alert (TCA) will be raised, making it possible to monitor the network and detect errors early.

Card threshold default settings are provided as follows:

PM thresholds—(OSCM, OSC-CSM, TXP, and MXP cards) Expressed in counts or seconds; includes line and SONET thresholds.

Optical thresholds—(ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards) Expressed in percentages or dBm; includes client and trunk optical thresholds.

OTN FEC thresholds (ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts; includes enhanced, standard, 1G Ethernet, 1G Fibre channel, 1G FICON, OC-3, OC-12, OC-48, 2G FICON, and 2G Fibre channel thresholds.

OTN G.709 thresholds (ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts or seconds; includes ITU-T G.709 PM and SM thresholds.

Threshold defaults are defined for near end and/or far end, at 15-minute and one-day intervals. Thresholds are further broken down by type, such as Multiplex Section, Regeneration Section, VC LO, MS, RS, or Path, for performance monitoring (PM) thresholds, and TCA (warning) or Alarm for physical thresholds. PM threshold types define the layer to which the threshold applies. Physical threshold types define the level of response expected when the threshold is crossed.


Note For full descriptions of the thresholds you can set for each card, see Chapter 17, "Performance Monitoring."



Note When LOS, LOS-P, or LOF alarms occur on transponder and muxponder trunks, ITU-T G.709/SONET/SDH TCAs are suppressed. For details, see "Alarm and TCA Monitoring and Management."



Note For additional information regarding PM parameter threshold defaults as defined by Telcordia specifications, refer to Telcordia GR-820-CORE and GR-253-CORE.


C.2.1.3  ANSI Defaults by Card

In the tables that follow, card defaults are defined by the default name, its factory-configured value, and the domain of allowable values that you can assign to it.


Note Some default values, such as certain thresholds, are interdependent. Before changing a value, review the domain for that default and any other related defaults for potential dependencies.


C.2.1.3.1  ANSI ADM-10G Card Default Settings

Table C-1 lists the ADM-10G card default settings.

Table C-1 ANSI ADM-10G Card Default Settings 

Default Name
Default Value
Default Domain

ADM-10G.config.interlink.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

ADM-10G.config.interlink.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

ADM-10G.config.interlink.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

ADM-10G.config.interlink.ppmPortAssignment

Internal Link

UNASSIGNED, Internal Link

ADM-10G.config.oc12.line.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

ADM-10G.config.oc12.line.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

ADM-10G.config.oc12.line.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

ADM-10G.config.oc12.line.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

ADM-10G.config.oc12.line.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

ADM-10G.config.oc12.line.SendDoNotUse

FALSE

TRUE, FALSE

ADM-10G.config.oc12.line.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

ADM-10G.config.oc12.line.SyncMsgIn

TRUE

FALSE, TRUE

ADM-10G.config.oc3.line.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

ADM-10G.config.oc3.line.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

ADM-10G.config.oc3.line.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

ADM-10G.config.oc3.line.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

ADM-10G.config.oc3.line.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

ADM-10G.config.oc3.line.SendDoNotUse

FALSE

TRUE, FALSE

ADM-10G.config.oc3.line.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

ADM-10G.config.oc3.line.SyncMsgIn

TRUE

FALSE, TRUE

ADM-10G.config.oc48.line.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

ADM-10G.config.oc48.line.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

ADM-10G.config.oc48.line.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

ADM-10G.config.oc48.line.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

ADM-10G.config.oc48.line.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

ADM-10G.config.oc48.line.SendDoNotUse

FALSE

TRUE, FALSE

ADM-10G.config.oc48.line.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

ADM-10G.config.oc48.line.SyncMsgIn

TRUE

FALSE, TRUE

ADM-10G.config.ppmSlotAssignment

PPM (1 Port)

UNASSIGNED, PPM (1 Port)

ADM-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

ADM-10G.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

ADM-10G.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

ADM-10G.config.trunk.ppmPortAssignment

OC192

UNASSIGNED, OC192

ADM-10G.etherPortConfig.AutoNegotiation

1000 Mbps

Auto, 1000 Mbps

ADM-10G.etherPortConfig.MTU

1548

1548, Jumbo

ADM-10G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc12.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc12.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc12.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc12.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.lr2.15min.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.15min.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.lr2.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.lr2.1day.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.1day.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.lr2.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.lr2.alarm.HighRxPower

-6.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.lr2.alarm.LowRxPower

-38.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.lr2.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc3.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc3.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc3.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc3.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.lr2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.lr2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.lr2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.sr1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.sr1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.sr1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.sr1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.client.oc48.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.client.oc48.sr1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.client.oc48.sr1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.client.oc48.sr1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.15min.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.1day.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.alarm.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.alarm.LowRxPower

-13.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.interlink.oc192.sr1.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.disabledfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.enhancedfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.dwdm.standardfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.15min.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.1day.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.alarm.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.alarm.LowRxPower

-13.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

ADM-10G.opticalthresholds.trunk.oc192.sr1.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

ADM-10G.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

ADM-10G.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

ADM-10G.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

ADM-10G.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

ADM-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

ADM-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

ADM-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

ADM-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

ADM-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

ADM-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

ADM-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

ADM-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

ADM-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

ADM-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

ADM-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

ADM-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

ADM-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

ADM-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

ADM-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

ADM-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

ADM-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

ADM-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

ADM-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

ADM-10G.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

ADM-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

ADM-10G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

ADM-10G.pmthresholds.oc12.line.farend.15min.CV

5315 (B2 count)

0 - 552600

ADM-10G.pmthresholds.oc12.line.farend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.farend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc12.line.farend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.farend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.farend.1day.CV

53150 (B2 count)

0 - 53049600

ADM-10G.pmthresholds.oc12.line.farend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.line.farend.1day.FC

40 (count)

0 - 72

ADM-10G.pmthresholds.oc12.line.farend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.line.farend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.line.nearend.15min.CV

5315 (B2 count)

0 - 552600

ADM-10G.pmthresholds.oc12.line.nearend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc12.line.nearend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.nearend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.line.nearend.1day.CV

53150 (B2 count)

0 - 53049600

ADM-10G.pmthresholds.oc12.line.nearend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.line.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.oc12.line.nearend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.line.nearend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.section.nearend.15min.CV

10000 (B1 count)

0 - 553500

ADM-10G.pmthresholds.oc12.section.nearend.15min.ES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.section.nearend.15min.SEFS

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.section.nearend.15min.SES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc12.section.nearend.1day.CV

100000 (B1 count)

0 - 53136000

ADM-10G.pmthresholds.oc12.section.nearend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc12.section.nearend.1day.SES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.farend.15min.CV

1312 (B2 count)

0 - 137700

ADM-10G.pmthresholds.oc3.line.farend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.farend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc3.line.farend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.farend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.farend.1day.CV

13120 (B2 count)

0 - 13219200

ADM-10G.pmthresholds.oc3.line.farend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.farend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.oc3.line.farend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.farend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.nearend.15min.CV

1312 (B2 count)

0 - 137700

ADM-10G.pmthresholds.oc3.line.nearend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc3.line.nearend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.nearend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.line.nearend.1day.CV

13120 (B2 count)

0 - 13219200

ADM-10G.pmthresholds.oc3.line.nearend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.oc3.line.nearend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.line.nearend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.section.nearend.15min.CV

10000 (B1 count)

0 - 138600

ADM-10G.pmthresholds.oc3.section.nearend.15min.ES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.section.nearend.15min.SEFS

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.section.nearend.15min.SES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc3.section.nearend.1day.CV

100000 (B1 count)

0 - 13305600

ADM-10G.pmthresholds.oc3.section.nearend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc3.section.nearend.1day.SES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

ADM-10G.pmthresholds.oc48.line.farend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.farend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc48.line.farend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.farend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

ADM-10G.pmthresholds.oc48.line.farend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.farend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.oc48.line.farend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.farend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

ADM-10G.pmthresholds.oc48.line.nearend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.oc48.line.nearend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.nearend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

ADM-10G.pmthresholds.oc48.line.nearend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.oc48.line.nearend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.line.nearend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

ADM-10G.pmthresholds.oc48.section.nearend.15min.ES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.section.nearend.15min.SEFS

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.section.nearend.15min.SES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.oc48.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

ADM-10G.pmthresholds.oc48.section.nearend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.oc48.section.nearend.1day.SES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

ADM-10G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

ADM-10G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

ADM-10G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

ADM-10G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

ADM-10G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

ADM-10G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

ADM-10G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

ADM-10G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

ADM-10G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

ADM-10G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.2  ANSI MXP_2.5G_10E Card Default Settings

Table C-2 lists the MXP_2.5G_10E card default settings.

Table C-2 ANSI MXP_2.5G_10E Card Default Settings 

Default Name
Default Value
Default Domain

MXP-2_5G-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

MXP-2_5G-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

MXP-2_5G-10E.config.client.ppmPortAssignment

OC48

UNASSIGNED, OC48

MXP-2_5G-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10E.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.config.client.sdh.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10E.config.client.sdh.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10E.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-2_5G-10E.config.client.sonet.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10E.config.client.sonet.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10E.config.client.TerminationMode

Transparent

Transparent, Section

MXP-2_5G-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.oc48.sr1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping

ODU Multiplex

ODU Multiplex

MXP-2_5G-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced

MXP-2_5G-10E.otn.otnLines.G709OTN

Enable

Enable

MXP-2_5G-10E.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.3  ANSI MXP_2.5G_10G Card Default Settings

Table C-3 lists the MXP_2.5G_10G card default settings.

Table C-3 ANSI MXP_2.5G_10G Card Default Settings 

Default Name
Default Value
Default Domain

MXP-2_5G-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-2_5G-10G.config.client.ppmPortAssignment

OC48

UNASSIGNED, OC48

MXP-2_5G-10G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.config.client.sdh.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10G.config.client.sdh.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-2_5G-10G.config.client.sonet.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10G.config.client.sonet.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10G.config.client.TerminationMode

Transparent

Transparent, Line

MXP-2_5G-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.oc48.sr1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

MXP-2_5G-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-2_5G-10G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.4  ANSI MXP_MR_2.5G Card Default Settings

Table C-4 lists the MXP_MR_2.5G card default settings.

Table C-4 ANSI MXP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

MXP-MR-2_5G.config.card.Mode

FC_GE

FC_GE, MIXED, ESCON

MXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL when //.card.Mode FC_GE; UNASSIGNED, ONE_GE, ESCON, FC1G ISL, FICON1G ISL when //.card.Mode MIXED; UNASSIGNED, ESCON when //.card.Mode ESCON

MXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2 - 256

MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-2_5G.config.trunk.sdh.SendDoNotUse

FALSE

TRUE, FALSE

MXP-MR-2_5G.config.trunk.sdh.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-MR-2_5G.config.trunk.sonet.SendDoNotUse

FALSE

TRUE, FALSE

MXP-MR-2_5G.config.trunk.sonet.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.5  ANSI MXPP_MR_2.5G Card Default Settings

Table C-5 lists the MXPP_MR_2.5G card default settings.

Table C-5 ANSI MXPP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

MXPP-MR-2_5G.config.card.Mode

FC_GE

FC_GE, MIXED, ESCON

MXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL when //.card.Mode FC_GE; UNASSIGNED, ONE_GE, ESCON, FC1G ISL, FICON1G ISL when //.card.Mode MIXED; UNASSIGNED, ESCON when //.card.Mode ESCON

MXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2 - 256

MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXPP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXPP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.6  ANSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings

Table C-6 lists the MXP_MR_10DME_C and MXP_MR_10DME_L card default settings.

Table C-6 ANSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings 

Default Name
Default Value
Default Domain

MXP-MR-10DME.config.card.Mode

Port 1-8: FC_GE_ISC

Port 1-8: FC_GE_ISC, Port 1-4: FC_GE_ISC, Port 5-8: FC4G, Port 1-4: FC4G, Port 5-8: FC_GE_ISC, Port 1-8: FC4G

MXP-MR-10DME.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-10DME.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-10DME.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

MXP-MR-10DME.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE-GE, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC3 PEER 1G, ISC3 PEER 2G when //.card.Mode Port 1-8: FC_GE_ISC; UNASSIGNED, FC4G_PORT when //.card.Mode Port 1-8: FC4G; UNASSIGNED, ONE-GE, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, FC4G, ISC3 PEER 1G, ISC3 PEER 2G when //.card.Mode Port 1-4: FC_GE_ISC, Port 5-8: FC4G, Port 1-4: FC4G, Port 5-8: FC_GE_ISC

MXP-MR-10DME.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-10DME.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-10DME.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-10DME.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-10DME.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-10DME.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

MXP-MR-10DME.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-10DME.config.trunk.SendDoNotUse

FALSE

FALSE, TRUE

MXP-MR-10DME.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-MR-10DME.config.trunk.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighTxPower

0.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighTxPower

0.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-MR-10DME.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-MR-10DME.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-MR-10DME.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-MR-10DME.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-MR-10DME.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-MR-10DME.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-MR-10DME.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.otnLines.AsynchSynchMapping

Synch Mapping

Synch Mapping

MXP-MR-10DME.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

MXP-MR-10DME.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-MR-10DME.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-10DME.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

MXP-MR-10DME.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

MXP-MR-10DME.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.7  ANSI TXP_MR_10E Card Default Settings

Table C-7 lists the TXP_MR_10E card default settings.

Table C-7 ANSI TXP_MR_10E Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

TXP-MR-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

TXP-MR-10E.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy, 10G Fiber Channel

TXP-MR-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-10E.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.client.sdh.SendDoNotUse

FALSE

TRUE, FALSE

TXP-MR-10E.config.client.sdh.SyncMsgIn

TRUE

FALSE, TRUE

TXP-MR-10E.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10E.config.client.sonet.SendDoNotUse

FALSE

TRUE, FALSE

TXP-MR-10E.config.client.sonet.SyncMsgIn

TRUE

FALSE, TRUE

TXP-MR-10E.config.client.TerminationMode

Transparent

Transparent, Section, Line when ppmPortAssignment UNASSIGNED, SONET (including 10G Ethernet WAN Phy); Transparent when ppmPortAssignment 10G Ethernet LAN Phy, 10G Fiber Channel

TXP-MR-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

6.0, 6.1, 6.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

TXP-MR-10E.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.ir5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.ir5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.15min.HighTxPower

8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.15min.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.1day.HighTxPower

8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.1day.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr2.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr2.alarm.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.lr5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.lr5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.p1l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.15min.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.1day.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.alarm.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr1.alarm.LowRxPower

-13.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr1.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.sr5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.sr5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.oc192.v3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.oc192.v3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.otnLines.AsynchSynchMapping

Synch Mapping

Asynch mapping, Synch Mapping

TXP-MR-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-10E.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10E.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.pmthresholds.client.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.line.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

TXP-MR-10E.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

TXP-MR-10E.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.8  ANSI TXP_MR_10G Card Default Settings

Table C-8 lists the TXP_MR_10G card default settings.

Table C-8 ANSI TXP_MR_10G Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-10G.config.client.mrPortAssignment

UNASSIGNED

UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy

TXP-MR-10G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10G.config.client.TerminationMode

Transparent

Transparent, Line when mrPortAssignment UNASSIGNED, SONET (including 10G Ethernet WAN Phy); Transparent when mrPortAssignment 10G Ethernet LAN Phy

TXP-MR-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-10G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.oc192.lw.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.oc192.lw.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0 - 7967700

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0 - 764899200

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.9  ANSI TXP_MR_2.5G Card Default Settings

Table C-9 lists the TXP_MR_2.5G card default settings.

Table C-9 ANSI TXP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, OC3, OC12, OC48, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-2_5G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Section, Line when ppmPortAssignment UNASSIGNED, OC3, OC12, OC48; Transparent when ppmPortAssignment OC3, OC12, OC48, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighRxPower

-6.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.LowRxPower

-38.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected

56457 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected

5419872 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected

15012 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected

1441152 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected

225837 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected

21680352 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-2_5G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV

5315 (B2 count)

0 - 552600

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV

53150 (B2 count)

0 - 53049600

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC

40 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV

5315 (B2 count)

0 - 552600

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV

53150 (B2 count)

0 - 53049600

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV

10000 (B1 count)

0 - 553500

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV

100000 (B1 count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV

1312 (B2 count)

0 - 137700

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV

13120 (B2 count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV

1312 (B2 count)

0 - 137700

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV

13120 (B2 count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV

10000 (B1 count)

0 - 138600

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV

100000 (B1 count)

0 - 13305600

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.10  ANSI TXPP_MR_2.5G Card Default Settings

Table C-10 lists the TXPP_MR_2.5G card default settings.

Table C-10 ANSI TXPP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

TXPP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, OC3, OC12, OC48, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXPP-MR-2_5G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Section, Line when ppmPortAssignment UNASSIGNED, OC3, OC12, OC48; Transparent when ppmPortAssignment OC3, OC12, OC48, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXPP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc12.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.LowRxPower

-34.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighRxPower

-6.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.LowRxPower

-38.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr2.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc3.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.oc48.sr1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected

56457 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected

5419872 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected

15012 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected

1441152 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected

225837 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected

21680352 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXPP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXPP-MR-2_5G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV

5315 (B2 count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV

53150 (B2 count)

0 - 53049600

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC

40 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV

5315 (B2 count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV

53150 (B2 count)

0 - 53049600

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV

10000 (B1 count)

0 - 553500

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV

100000 (B1 count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV

1312 (B2 count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV

13120 (B2 count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV

1312 (B2 count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV

13120 (B2 count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV

10000 (B1 count)

0 - 138600

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV

100000 (B1 count)

0 - 13305600

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV

21260 (B2 count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV

212600 (B2 count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV

21260 (B2 count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV

212600 (B2 count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV

10000 (B1 count)

0 - 2151900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV

100000 (B1 count)

0 - 206582400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.11  ANSI GE_XP Card Default Settings

Table C-11 lists the GE_XP card default settings.

Table C-11 ANSI GE_XP Card Default Settings 

Default Name
Default Value
Default Domain

XP-GE.config.card.Mode

10GE MXP

20GE MXP, 10GE MXP, L2 over DWDM

XP-GE.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

XP-GE.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-GE.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

XP-GE.config.client.cEtherType

8100 (Hex)

Free form field

XP-GE.config.client.CommittedBurstSize

4K

4K, 8K, 16K .. 16M

XP-GE.config.client.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-GE.config.client.ExcessBurstSize

4K

4K, 8K, 16K .. 16M

XP-GE.config.client.FlowControl

OFF

OFF, ON

XP-GE.config.client.macLearningState

OFF

OFF, ON

XP-GE.config.client.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-GE.config.client.niMode

UNI MODE

UNI MODE, NNI MODE

XP-GE.config.client.sEtherType

8100 (Hex)

Free form field

XP-GE.config.client.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-GE.config.client.Speed

Auto

1000 Mbps, Auto

XP-GE.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

XP-GE.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-GE.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

XP-GE.config.trunk.cEtherType

8100 (Hex)

Free form field

XP-GE.config.trunk.CommittedBurstSize

4K

4K, 8K, 16K .. 16M

XP-GE.config.trunk.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-GE.config.trunk.ExcessBurstSize

4K

4K, 8K, 16K .. 16M

XP-GE.config.trunk.FlowControl

OFF

OFF, ON

XP-GE.config.trunk.macLearningState

OFF

OFF, ON

XP-GE.config.trunk.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-GE.config.trunk.niMode

NNI MODE

UNI MODE, NNI MODE

XP-GE.config.trunk.sEtherType

8100 (Hex)

Free form field

XP-GE.config.trunk.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-GE.config.trunk.Speed

10000 Mbps

10000 Mbps

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-GE.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-GE.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-GE.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-GE.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-GE.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-GE.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-GE.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-GE.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

XP-GE.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

XP-GE.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

XP-GE.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

XP-GE.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

XP-GE.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

XP-GE.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

XP-GE.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

XP-GE.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

XP-GE.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

XP-GE.otn.otnLines.G709OTN

Enable

Disable, Enable

XP-GE.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9


C.2.1.3.12  ANSI 10GE_XP Card Default Settings

Table C-12 lists the 10GE_XP card default settings.

Table C-12 ANSI 10GE_XP Card Default Settings 

Default Name
Default Value
Default Domain

XP-10GE.config.card.Mode

10GE TXP

10GE TXP, L2 over DWDM

XP-10GE.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

XP-10GE.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-10GE.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

XP-10GE.config.client.cEtherType

8100 (Hex)

Free form field

XP-10GE.config.client.CommittedBurstSize

4K

4K, 8K, 16K .. 16M

XP-10GE.config.client.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-10GE.config.client.ExcessBurstSize

4K

4K, 8K, 16K .. 16M

XP-10GE.config.client.FlowControl

OFF

OFF, ON

XP-10GE.config.client.macLearningState

OFF

OFF, ON

XP-10GE.config.client.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-10GE.config.client.niMode

UNI MODE

UNI MODE, NNI MODE

XP-10GE.config.client.sEtherType

8100 (Hex)

Free form field

XP-10GE.config.client.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-10GE.config.client.Speed

10000 Mbps

10000 Mbps

XP-10GE.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

XP-10GE.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-10GE.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

XP-10GE.config.trunk.cEtherType

8100 (Hex)

Free form field

XP-10GE.config.trunk.CommittedBurstSize

4K

4K, 8K, 16K .. 16M

XP-10GE.config.trunk.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-10GE.config.trunk.ExcessBurstSize

4K

4K, 8K, 16K .. 16M

XP-10GE.config.trunk.FlowControl

OFF

OFF, ON

XP-10GE.config.trunk.macLearningState

OFF

OFF, ON

XP-10GE.config.trunk.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-10GE.config.trunk.niMode

NNI MODE

UNI MODE, NNI MODE

XP-10GE.config.trunk.sEtherType

8100 (Hex)

Free form field

XP-10GE.config.trunk.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-10GE.config.trunk.Speed

10000 Mbps

10000 Mbps

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-10GE.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-10GE.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-10GE.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-10GE.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-10GE.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-10GE.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-10GE.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-10GE.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

XP-10GE.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

XP-10GE.otn.otnLines.G709OTN

Enable

Disable, Enable

XP-10GE.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9


C.2.1.3.13  ANSI OSCM Card Default Settings

Table C-13 lists the OSCM card default settings.

Table C-13 ANSI OSCM Card Default Settings 

Default Name
Default Value
Default Domain

OSCM.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OSCM.pmthresholds.line.farend.15min.CV

1312 (B2 count)

0 - 137700

OSCM.pmthresholds.line.farend.15min.ES

87 (seconds)

0 - 900

OSCM.pmthresholds.line.farend.15min.FC

10 (count)

0 - 72

OSCM.pmthresholds.line.farend.15min.SES

1 (seconds)

0 - 900

OSCM.pmthresholds.line.farend.15min.UAS

3 (seconds)

0 - 900

OSCM.pmthresholds.line.farend.1day.CV

13120 (B2 count)

0 - 13219200

OSCM.pmthresholds.line.farend.1day.ES

864 (seconds)

0 - 86400

OSCM.pmthresholds.line.farend.1day.FC

40 (count)

0 - 6912

OSCM.pmthresholds.line.farend.1day.SES

4 (seconds)

0 - 86400

OSCM.pmthresholds.line.farend.1day.UAS

10 (seconds)

0 - 86400

OSCM.pmthresholds.line.nearend.15min.CV

1312 (B2 count)

0 - 137700

OSCM.pmthresholds.line.nearend.15min.ES

87 (seconds)

0 - 900

OSCM.pmthresholds.line.nearend.15min.FC

10 (count)

0 - 72

OSCM.pmthresholds.line.nearend.15min.SES

1 (seconds)

0 - 900

OSCM.pmthresholds.line.nearend.15min.UAS

3 (seconds)

0 - 900

OSCM.pmthresholds.line.nearend.1day.CV

13120 (B2 count)

0 - 13219200

OSCM.pmthresholds.line.nearend.1day.ES

864 (seconds)

0 - 86400

OSCM.pmthresholds.line.nearend.1day.FC

40 (count)

0 - 6912

OSCM.pmthresholds.line.nearend.1day.SES

4 (seconds)

0 - 86400

OSCM.pmthresholds.line.nearend.1day.UAS

10 (seconds)

0 - 86400

OSCM.pmthresholds.section.nearend.15min.CV

10000 (B1 count)

0 - 138600

OSCM.pmthresholds.section.nearend.15min.ES

500 (seconds)

0 - 900

OSCM.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

0 - 900

OSCM.pmthresholds.section.nearend.15min.SES

500 (seconds)

0 - 900

OSCM.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

0 - 13305600

OSCM.pmthresholds.section.nearend.1day.ES

5000 (seconds)

0 - 86400

OSCM.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

OSCM.pmthresholds.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.14  ANSI OSC-CSM Card Default Settings

Table C-14 lists the OSC-CSM card default settings.

Table C-14 ANSI OSC-CSM Card Default Settings 

Default Name
Default Value
Default Domain

OSC_CSM.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OSC_CSM.pmthresholds.line.farend.15min.CV

1312 (B2 count)

0 - 137700

OSC_CSM.pmthresholds.line.farend.15min.ES

87 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.farend.15min.FC

10 (count)

0 - 72

OSC_CSM.pmthresholds.line.farend.15min.SES

1 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.farend.15min.UAS

3 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.farend.1day.CV

13120 (B2 count)

0 - 13219200

OSC_CSM.pmthresholds.line.farend.1day.ES

864 (seconds)

0 - 86400

OSC_CSM.pmthresholds.line.farend.1day.FC

40 (count)

0 - 6912

OSC_CSM.pmthresholds.line.farend.1day.SES

4 (seconds)

0 - 86400

OSC_CSM.pmthresholds.line.farend.1day.UAS

10 (seconds)

0 - 86400

OSC_CSM.pmthresholds.line.nearend.15min.CV

1312 (B2 count)

0 - 137700

OSC_CSM.pmthresholds.line.nearend.15min.ES

87 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.nearend.15min.FC

10 (count)

0 - 72

OSC_CSM.pmthresholds.line.nearend.15min.SES

1 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.nearend.15min.UAS

3 (seconds)

0 - 900

OSC_CSM.pmthresholds.line.nearend.1day.CV

13120 (B2 count)

0 - 13219200

OSC_CSM.pmthresholds.line.nearend.1day.ES

864 (seconds)

0 - 86400

OSC_CSM.pmthresholds.line.nearend.1day.FC

40 (count)

0 - 6912

OSC_CSM.pmthresholds.line.nearend.1day.SES

4 (seconds)

0 - 86400

OSC_CSM.pmthresholds.line.nearend.1day.UAS

10 (seconds)

0 - 86400

OSC_CSM.pmthresholds.section.nearend.15min.CV

10000 (B1 count)

0 - 138600

OSC_CSM.pmthresholds.section.nearend.15min.ES

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.section.nearend.15min.SES

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

0 - 13305600

OSC_CSM.pmthresholds.section.nearend.1day.ES

5000 (seconds)

0 - 86400

OSC_CSM.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

0 - 86400

OSC_CSM.pmthresholds.section.nearend.1day.SES

5000 (seconds)

0 - 86400


C.2.1.3.15  ANSI Amplifier Card Default Settings

Table C-15 lists the OPT-BST and OPT-BST-L card default settings.

Table C-15 ANSI Amplifier Card Default Settings 

Default Name
Default Value
Default Domain

OPT-AMP-17-C.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OPT-BST.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OPT-BST-L.config.card.AlsMode

Auto Restart

Disabled, Auto Restart


C.2.2  ANSI Node Default Settings

Table C-16 lists the node-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:

Circuit settings—Set the administrative state and path protection circuit defaults, and whether to have circuits send a payload defect indication condition (PDIP).

General settings—Set general node management defaults, including whether to use Daylight Savings Time (DST), whether to insert Alarm Indication Signal VT (AIS-V) in each VT when the carrying STS crosses the signal degrade (SD) path bit error rate (BER) threshold, the IP address of the Network Time Protocol/Simple Network Time Protocol (NTP/SNTP) server to be used, the time zone where the node is located, the SD path BER value, the defaults description, whether to raise a condition on an empty card slot, whether automatic autonomous Transcation Language One (TL1) reporting of PM data is enabled for cross-connect paths on the node, whether or not to allow ports to be disabled when they are providing services (when the default is set to FALSE users must remove or disable the services first, then put the ports out of service), and whether to report loopback conditions on Out-of-Service, Maintenance (OOS-MT) state ports.

Link Management Protocol settings—Set link management protocol data link type, traffic engineering link, and general settings.

Power Monitor settings—Set default voltage thresholds for the node.

Network settings—Set whether to prevent display of node IP addresses in CTC (applicable for all users except Superusers); default gateway node type; whether to raise an alarm when the backplane LAN cable is disconnected; and whether to display the IP address in the LCD in an editable mode (in which you can change the IP address directly from LCD screen), to display the IP address on the LCD as read-only, or to suppress display of the IP on the LCD entirely.

OSI settings—Set the Open System Interconnection (OSI) main setup, generic routing encapsulation (GRE) tunnel, link access protocol on the D channel (LAP-D), the router subnet, and the TID address resolution protocol (TARP) settings.

1+1 and Optimized 1+1 protection settings—Set whether or not protected circuits have bidirectional switching, are revertive, and what the reversion time is; set optimized 1+1 detection, recovery, and verify guard timer values.


Note Optimized 1+1 supports three timers that ensure the correct state of the cards at key points in card communication. A verification guard timer is used when a Force is issued, to ensure that the far end has a chance to respond. A detection guard timer is used to ensure the presence of an SF/SD condition before switching away from a card. A recover guard timer ensures the absence of SF/SD prior to switching to a card. You can change the default number of seconds before these timers expire by changing the NE default for the corresponding timer to a value within its domain of allowable values.


BLSR protection settings—Set whether BLSR-protected circuits are revertive, and what the reversion time is, at both the ring and span levels.

Y Cable protection settings—Set whether Y-cable protected circuits are revertive, and what the reversion time is.

Splitter protection settings—Set whether splitter protected circuits are revertive, and what the reversion time is.

Legal Disclaimer—Set the legal disclaimer that warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.

Security Grant Permissions—Set default user security levels for activating/reverting software, PM data clearing, database restoring, and retrieving audit logs.

Security DataComm settings—Set default security settings for TCC Ethernet IP address and IP netmask, and CTC backplane IP suppression; set secure mode on and secure mode locked (for TCC2P cards only).

Security Access settings—Set default security settings for LAN access, shell access, serial craft access, element management system (EMS) access (including Internet Inter-Object Request Broker Protocol [IIOP] listener port number), TL1 access, and Simple Network Management Protocol (SNMP) access.

Security RADIUS settings—Set default RADIUS server settings for the accounting port number and the authentication port number, and whether to enable the node as a final authenticator.

Security Policy settings—Set the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference that is required between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.

Security Password settings—Set when passwords can be changed, how many characters they must differ by, whether or not password reuse is allowed, and whether a password change is required on first login to a new account; set password aging enforcement and user-level specific aging and warning periods; set how many consecutive identical characters are allowed in a password, maximum password length, minimum password length, minimum number and combination of nonalphabetical characters required, and whether or not to allow a password that is a reversal of the login ID associated with the password.

BITS Timing settings—Set the AIS threshold, Admin synchronization status messaging (SSM), coding, facility type, framing, state, and line build-out (LBO) settings for building integrated timing supply 1 (BITS-1) and BITS2 timing.

General Timing settings—Set the mode (External, Line, or Mixed), quality of reserved (RES) timing (the rule that defines the order of clock quality from lowest to highest), revertive, reversion time, and SSM message set for node timing.


Note For more information about each individual node setting, refer to the "Manage the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide.


Table C-16 ANSI Node Default Settings 

Default Name
Default Value
Default Domain

NODE.circuits.SendPDIP

TRUE

TRUE, FALSE

NODE.circuits.State

IS,AINS

IS, OOS,DSBLD, OOS,MT, IS,AINS

NODE.circuits.upsr.AllowUpsrOverOnePlusOne

FALSE

TRUE, FALSE

NODE.circuits.upsr.ProvisionWorkingGoAndReturnOnPrimaryPath

TRUE

TRUE, FALSE

NODE.circuits.upsr.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.circuits.upsr.Revertive

FALSE

TRUE, FALSE

NODE.circuits.upsr.STS_SDBER

1.00E-06

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.circuits.upsr.STS_SFBER

1.00E-04

1E-3, 1E-4, 1E-5

NODE.circuits.upsr.SwitchOnPDIP

FALSE

TRUE, FALSE

NODE.circuits.upsr.VT_SDBER

1.00E-05

1E-5, 1E-6, 1E-7, 1E-8

NODE.circuits.upsr.VT_SFBER

1.00E-03

1E-3, 1E-4, 1E-5

NODE.general.AllowServiceAffectingPortChangeToDisabled

TRUE

FALSE, TRUE

NODE.general.AutoPM

FALSE

FALSE, TRUE

NODE.general.DefaultsDescription

Factory Defaults

Free form field

NODE.general.InsertAISVOnSDP

FALSE

TRUE, FALSE

NODE.general.NtpSntpServer

0.0.0.0

IP Address

NODE.general.RaiseConditionOnEmptySlot

FALSE

TRUE, FALSE

NODE.general.ReportLoopbackConditionsOnOOS-MTPorts

FALSE

FALSE, TRUE

NODE.general.SDPBER

1.00E-06

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.general.TimeZone

(GMT-08:00) Pacific Time (US & Canada), Tijuana

(For applicable time zones, see Table C-17.)

NODE.general.UseDST

TRUE

TRUE, FALSE

NODE.lmp.controlChannel.AdminState

OOS,DSBLD

IS, OOS,DSBLD

NODE.lmp.controlChannel.HelloDeadInterval

12000 (ms)

maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)), maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 1, maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 2 .. minimum_of(20000,MaxHelloDeadInterval)

NODE.lmp.controlChannel.HelloInterval

500 (ms)

maximum_of(300,MinHelloInterval), maximum_of(300,MinHelloInterval) + 1, maximum_of(300,MinHelloInterval) + 2 .. minimum_of(5000,MaxHelloInterval,quotient_of(HelloDeadInterval,3))

NODE.lmp.controlChannel.MaxHelloDeadInterval

20000 (ms)

maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)), maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 1, maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 2 .. 20000

NODE.lmp.controlChannel.MaxHelloInterval

2000 (ms)

maximum_of(300,HelloInterval), maximum_of(300,HelloInterval) + 1, maximum_of(300,HelloInterval) + 2 .. minimum_of(5000,difference_of(MaxHelloDeadInterval,1))

NODE.lmp.controlChannel.MinHelloDeadInterval

2000 (ms)

maximum_of(2000,sum_of(MinHelloInterval,1)), maximum_of(2000,sum_of(MinHelloInterval,1)) + 1, maximum_of(2000,sum_of(MinHelloInterval,1)) + 2 .. minimum_of(20000,HelloDeadInterval)

NODE.lmp.controlChannel.MinHelloInterval

300 (ms)

300, 301, 302 .. minimum_of(5000,HelloInterval,difference_of(MinHelloDeadInterval,1))

NODE.lmp.dataLink.Type

Port

Port, Component

NODE.lmp.general.Allowed

TRUE

FALSE, TRUE

NODE.lmp.general.Enabled

FALSE

FALSE, TRUE when Allowed TRUE; FALSE when Allowed FALSE

NODE.lmp.general.LMP-WDM

TRUE

FALSE, TRUE

NODE.lmp.general.Role

OLS

PEER, OLS

NODE.lmp.teLink.AdminState

OOS,DSBLD

IS, OOS,DSBLD

NODE.lmp.teLink.DWDM

TRUE

FALSE, TRUE

NODE.lmp.teLink.MuxCapability

Lambda Switch

Packet Switch - Level 1, Packet Switch - Level 2, Packet Switch - Level 3, Packet Switch - Level 4, Layer 2 Switch, TDM Cross-connect, Lambda Switch, Fiber Switch

NODE.network.general.AlarmMissingBackplaneLAN

FALSE

TRUE, FALSE

NODE.network.general.CtcIpDisplaySuppression

FALSE

TRUE, FALSE

NODE.network.general.GatewaySettings

None

LeaveAsIs, None, ENE, GNE, ProxyOnlyNode

NODE.network.general.LcdSetting

Allow Configuration

Allow Configuration, Display Only, Suppress Display

NODE.osi.greTunnel.OspfCost

110

110 - 65535

NODE.osi.greTunnel.SubnetMask

24 (bits)

8, 9, 10 .. 32

NODE.osi.lapd.Mode

AITS

AITS, UITS

NODE.osi.lapd.MTU

512

512, 513, 514 .. 1500

NODE.osi.lapd.Role

Network

Network, User

NODE.osi.lapd.T200

200 (ms)

200, 300, 400 .. 20000

NODE.osi.lapd.T203

10000 (ms)

4000, 4100, 4200 .. 120000

NODE.osi.mainSetup.L1L2LSPBufferSize

512 (bytes)

512 - 1500

NODE.osi.mainSetup.L1LSPBufferSize

512 (bytes)

512 - 1500

NODE.osi.mainSetup.NodeRoutingMode

Intermediate System Level 1

End System, Intermediate System Level 1, Intermediate System Level 1/Level 2

NODE.osi.subnet.DISPriority

63

1, 2, 3 .. 127

NODE.osi.subnet.ESH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.GCCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.IIH

3 (sec)

1, 2, 3 .. 600

NODE.osi.subnet.ISH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.LANISISCost

20

1, 2, 3 .. 63

NODE.osi.subnet.LDCCISISCost

40

1, 2, 3 .. 63

NODE.osi.subnet.OSCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.SDCCISISCost

60

1, 2, 3 .. 63

NODE.osi.tarp.L1DataCache

TRUE

FALSE, TRUE

NODE.osi.tarp.L2DataCache

FALSE

FALSE, TRUE

NODE.osi.tarp.LANStormSuppression

TRUE

FALSE, TRUE

NODE.osi.tarp.LDB

TRUE

FALSE, TRUE

NODE.osi.tarp.LDBEntry

5 (min)

1 - 10

NODE.osi.tarp.LDBFlush

5 (min)

0 - 1440

NODE.osi.tarp.PDUsL1Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsL2Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsOrigination

TRUE

FALSE, TRUE

NODE.osi.tarp.T1Timer

15 (sec)

0 - 3600

NODE.osi.tarp.T2Timer

25 (sec)

0 - 3600

NODE.osi.tarp.T3Timer

40 (sec)

0 - 3600

NODE.osi.tarp.T4Timer

20 (sec)

0 - 3600

NODE.osi.tarp.Type4PDUDelay

0 (sec)

0 - 255

NODE.powerMonitor.EHIBATVG

-56.5 (Vdc)

-54.0, -54.5, -55.0, -55.5, -56.0, -56.5

NODE.powerMonitor.ELWBATVG

-40.5 (Vdc)

-40.5, -41.0, -41.5, -42.0, -42.5, -43.0, -43.5, -44.0

NODE.powerMonitor.HIBATVG

-54.0 (Vdc)

-44.0, -44.5, -45.0 .. -56.5

NODE.powerMonitor.LWBATVG

-44.0 (Vdc)

-40.5, -41.0, -41.5 .. -54.0

NODE.protection.1+1.BidirectionalSwitching

FALSE

TRUE, FALSE

NODE.protection.1+1.DetectionGuardTimer

1 (seconds)

0, 0.05, 0.1, 0.5, 1, 2, 3, 4, 5

NODE.protection.1+1.RecoveryGuardTimer

1 (seconds)

0, 0.05, 0.1 .. 10

NODE.protection.1+1.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.1+1.Revertive

FALSE

TRUE, FALSE

NODE.protection.1+1.VerifyGuardTimer

0.5 (seconds)

0.5, 1

NODE.protection.blsr.RingReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.blsr.RingRevertive

TRUE

TRUE, FALSE

NODE.protection.blsr.SpanReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.blsr.SpanRevertive

TRUE

TRUE, FALSE

NODE.protection.splitter.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.splitter.Revertive

FALSE

TRUE, FALSE

NODE.protection.ycable.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.ycable.Revertive

FALSE

TRUE, FALSE

NODE.security.dataComm.CtcBackplaneIpDisplaySuppression

TRUE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.DefaultTCCEthernetIP

10.0.0.1

IP Address

NODE.security.dataComm.DefaultTCCEthernetIPNetmask

24 (bits)

8, 9, 10 .. 32

NODE.security.dataComm.isSecureModeSupportedOnControlCard

TRUE

FALSE, TRUE

NODE.security.dataComm.LcdBackplaneIpSetting

Display Only

Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.SecureModeLocked

FALSE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.SecureModeOn (May reboot node)

FALSE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.emsAccess.AccessState

NonSecure

NonSecure, Secure

NODE.security.emsAccess.IIOPListenerPort (May reboot node)

57790 (port #)

0 - 65535

NODE.security.grantPermission.ActivateRevertSoftware

Superuser

Provisioning, Superuser

NODE.security.grantPermission.PMClearingPrivilege

Provisioning

Provisioning, Superuser

NODE.security.grantPermission.RestoreDB

Superuser

Provisioning, Superuser

NODE.security.grantPermission.RetrieveAuditLog

Superuser

Provisioning, Superuser

NODE.security.idleUserTimeout.Maintenance

01:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Provisioning

00:30 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Retrieve

00:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Superuser

00:15 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.lanAccess.LANAccess (May disconnect CTC from node)

Front & Backplane

No LAN Access, Front Only, Backplane Only, Front & Backplane

NODE.security.lanAccess.RestoreTimeout

5 (minutes)

0 - 60

NODE.security.legalDisclaimer.LoginWarningMessage

<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.

Free form field

NODE.security.other.DisableInactiveUser

FALSE

FALSE, TRUE

NODE.security.other.InactiveDuration

45 (days)

1, 2, 3 .. 99 when nothing TRUE; 45 when nothing FALSE

NODE.security.other.SingleSessionPerUser

FALSE

TRUE, FALSE

NODE.security.passwordAging.EnforcePasswordAging

FALSE

TRUE, FALSE

NODE.security.passwordAging.maintenance.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.maintenance.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.provisioning.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.provisioning.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.retrieve.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.retrieve.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.superuser.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.superuser.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordChange.CannotChangeNewPassword

FALSE

TRUE, FALSE

NODE.security.passwordChange.CannotChangeNewPasswordForNDays

20 (days)

20 - 95

NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters

1 (characters)

1 - 5

NODE.security.passwordChange.PreventReusingLastNPasswords

1 (times)

1 - 10

NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount

FALSE

TRUE, FALSE

NODE.security.passwordComplexity.IdenticalConsecutiveCharactersAllowed

3 or more

0-2, 3 or more

NODE.security.passwordComplexity.MaximumLength

20

20, 80

NODE.security.passwordComplexity.MinimumLength

6

6, 8, 10, 12

NODE.security.passwordComplexity.MinimumRequiredCharacters

1 num, 1 letter & 1 TL1 special

1 num, 1 letter & 1 TL1 special, 1 num, 1 letter & 1 special, 2 each of any 2 of num, upper, lower & TL1 special, 2 each of any 2 of num, upper, lower & special

NODE.security.passwordComplexity.ReverseUserIdAllowed

TRUE

TRUE, FALSE

NODE.security.radiusServer.AccountingPort

1813 (port)

0 - 32767

NODE.security.radiusServer.AuthenticationPort

1812 (port)

0 - 32767

NODE.security.radiusServer.EnableNodeAsFinalAuthenticator

TRUE

FALSE, TRUE

NODE.security.serialCraftAccess.EnableCraftPort

TRUE

TRUE, FALSE

NODE.security.shellAccess.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.shellAccess.EnableShellPassword

FALSE

TRUE, FALSE

NODE.security.shellAccess.TelnetPort

23

23 - 9999

NODE.security.snmpAccess.AccessState

NonSecure

Disabled, NonSecure

NODE.security.tl1Access.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.userLockout.FailedLoginsAllowedBeforeLockout

5 (times)

0 - 10

NODE.security.userLockout.LockoutDuration

00:30 (mins:secs)

00:00, 00:05, 00:10 .. 10:00

NODE.security.userLockout.ManualUnlockBySuperuser

FALSE

TRUE, FALSE

NODE.software.AllowDelayedUpgrades

FALSE

FALSE, TRUE

NODE.software.DefaultDelayedUpgrades

FALSE

FALSE, TRUE when AllowDelayedUpgrades TRUE; FALSE when AllowDelayedUpgrades FALSE

NODE.timing.bits-1.AdminSSMIn

STU

PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A

NODE.timing.bits-1.AISThreshold

SMC

PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A

NODE.timing.bits-1.Coding

B8ZS

B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz

NODE.timing.bits-1.CodingOut

B8ZS

B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz

NODE.timing.bits-1.FacilityType

DS1

DS1, 64kHz+8kHz when //.general.TimingStandard SONET; E1, 64kHz+8kHz, 2MHz when //.general.TimingStandard SDH

NODE.timing.bits-1.FacilityTypeOut

DS1

DS1, 6MHz when //.general.TimingStandard SONET; E1, 6MHz, 2MHz when //.general.TimingStandard SDH

NODE.timing.bits-1.Framing

ESF

ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-1.FramingOut

ESF

ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz

NODE.timing.bits-1.LBO

0-133

0-133, 134-266, 267-399, 400-533, 534-655

NODE.timing.bits-1.SaBit

N/A

N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-1.State

OOS,DSBLD

IS, OOS,DSBLD

NODE.timing.bits-1.StateOut

OOS,DSBLD

IS, OOS,DSBLD

NODE.timing.bits-2.AdminSSMIn

STU

PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A

NODE.timing.bits-2.AISThreshold

SMC

PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A

NODE.timing.bits-2.Coding

B8ZS

B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz

NODE.timing.bits-2.CodingOut

B8ZS

B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz

NODE.timing.bits-2.FacilityType

DS1

DS1, 64kHz+8kHz when //.general.TimingStandard SONET; E1, 64kHz+8kHz, 2MHz when //.general.TimingStandard SDH

NODE.timing.bits-2.FacilityTypeOut

DS1

DS1, 6MHz when //.general.TimingStandard SONET; E1, 6MHz, 2MHz when //.general.TimingStandard SDH

NODE.timing.bits-2.Framing

ESF

ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-2.FramingOut

ESF

ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz

NODE.timing.bits-2.LBO

0-133

0-133, 134-266, 267-399, 400-533, 534-655

NODE.timing.bits-2.SaBit

N/A

N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-2.State

OOS,DSBLD

IS, OOS,DSBLD

NODE.timing.bits-2.StateOut

OOS,DSBLD

IS, OOS,DSBLD

NODE.timing.general.Mode

Line

External, Line, Mixed

NODE.timing.general.QualityOfRES

RES=DUS

PRS<RES, STU<RES<PRS, ST2<RES<STU, ST3<RES<ST2, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet Generation 1; PRS<RES, STU<RES<PRS, ST2<RES<STU, TNC<RES<ST2, ST3E<RES<TNC, ST3<RES<ST3E, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet Generation 2; N/A when SSMMessageSet N/A

NODE.timing.general.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.timing.general.Revertive

TRUE

TRUE, FALSE

NODE.timing.general.SSMMessageSet

Generation 1

Generation 1, Generation 2 when TimingStandard SONET; N/A when TimingStandard SDH

NODE.timing.general.TimingStandard

SONET

SONET, SDH


C.2.2.1  Time Zones

Table C-17 lists the time zones that apply for node time zone defaults. Time zones in the table are ordered by their relative relationships to Greenwich Mean Time (GMT), and the default values are displayed in the correct format for valid default input.

Table C-17 Time Zones 

Time Zone (GMT +/- Hours)
Default Value

GMT-11:00

(GMT-11:00) Midway Islands, Samoa

GMT-10:00

(GMT-10:00) Hawaiian Islands, Tahiti

GMT-09:00

(GMT-09:00) Anchorage - Alaska

GMT-08:00

(GMT-08:00) Pacific Time (US & Canada), Tijuana

GMT-07:00

(GMT-07:00) Mountain Time (US & Canada)

GMT-07:00

(GMT-07:00) Phoenix - Arizona

GMT-06:00

(GMT-06:00) Central Time (US & Canada)

GMT-06:00

(GMT-06:00) Mexico City

GMT-06:00

(GMT-06:00) Costa Rica, Managua, San Salvador

GMT-06:00

(GMT-06:00) Saskatchewan

GMT-05:00

(GMT-05:00) Bogota, Lima, Quito

GMT-05:00

(GMT-05:00) Eastern Time (US & Canada)

GMT-05:00

(GMT-05:00) Havana

GMT-05:00

(GMT-05:00) Indiana (US)

GMT-04:00

(GMT-04:00) Asuncion

GMT-04:00

(GMT-04:00) Caracas, La Paz, San Juan

GMT-04:00

(GMT-04:00) Atlantic Time (Canada), Halifax, Saint John, Charlottetown

GMT-04:00

(GMT-04:00) Santiago

GMT-04:00

(GMT-04:00) Thule (Qaanaaq)

GMT-03:30

(GMT-03:30) St. John's - Newfoundland

GMT-03:00

(GMT-03:00) Brasilia, Rio de Janeiro, Sao Paulo

GMT-03:00

(GMT-03:00) Buenos Aires, Georgetown

GMT-03:00

(GMT-03:00) Godthab (Nuuk) - Greenland

GMT-02:00

(GMT-02:00) Mid-Atlantic

GMT-01:00

(GMT-01:00) Azores, Scoresbysund

GMT-01:00

(GMT-01:00) Praia - Cape Verde

GMT 00:00

(GMT 00:00) Casablanca, Reykjavik, Monrovia

GMT

(GMT) Greenwich Mean Time

GMT 00:00

(GMT 00:00) Dublin, Edinburgh, London, Lisbon

GMT+01:00

(GMT+01:00) Amsterdam, Berlin, Rome, Stockholm, Paris

GMT+01:00

(GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague

GMT+01:00

(GMT+01:00) Brussels, Copenhagen, Madrid, Vienna

GMT+01:00

(GMT+01:00) Sarajevo, Skopje, Sofija, Vilnius, Warsaw, Zagreb

GMT+01:00

(GMT+01:00) West Central Africa, Algiers, Lagos, Luanda

GMT+01:00

(GMT+01:00) Windhoek (Namibia)

GMT+02:00

(GMT+02:00) Al Jizah, Alexandria, Cairo

GMT+02:00

(GMT+02:00) Amman

GMT+02:00

(GMT+02:00) Athens, Bucharest, Istanbul

GMT+02:00

(GMT+02:00) Beirut

GMT+02:00

(GMT+02:00) Cape Town, Harare, Johannesburg, Pretoria

GMT+02:00

(GMT+02:00) Jerusalem

GMT+02:00

(GMT+02:00) Kaliningrad, Minsk

GMT+03:00

(GMT+03:00) Aden, Antananarivo, Khartoum, Nairobi

GMT+03:00

(GMT+03:00) Baghdad

GMT+03:00

(GMT+03:00) Kuwait, Riyadh

GMT+03:00

(GMT+03:00) Moscow, St. Petersburg, Novgorod

GMT+03:30

(GMT+03:30) Tehran

GMT+04:00

(GMT+04:00) Abu Dhabi, Mauritius, Muscat

GMT+04:00

(GMT+04:00) Aqtau, T'bilisi

GMT+04:00

(GMT+04:00) Baku

GMT+04:00

(GMT+04:00) Yerevan, Samara

GMT+04:30

(GMT+04:30) Kabul

GMT+05:00

(GMT+05:00) Chelyabinsk, Prem, Yekaterinburg, Ufa

GMT+05:00

(GMT+05:00) Islamabad, Karachi, Tashkent

GMT+05:30

(GMT+05:30) Calcutta, Mumbai, New Delhi, Chennai

GMT+05:45

(GMT+05:45) Kathmandu

GMT+06:00

(GMT+06:00) Almaty

GMT+06:00

(GMT+06:00) Colombo, Dhaka, Astana

GMT+06:00

(GMT+06:00) Novosibirsk, Omsk

GMT+06:30

(GMT+06:30) Cocos, Rangoon

GMT+07:00

(GMT+07:00) Bangkok, Hanoi, Jakarta

GMT+07:00

(GMT+07:00) Krasnoyarsk, Norilsk, Novokuznetsk

GMT+08:00

(GMT+08:00) Irkutsk, Ulaan Bataar

GMT+08:00

(GMT+08:00) Beijing, Shanghai, Hong Kong, Urumqi

GMT+08:00

(GMT+08:00) Perth

GMT+08:00

(GMT+08:00) Singapore, Manila, Taipei, Kuala Lumpur

GMT+09:00

(GMT+09:00) Chita, Yakutsk

GMT+09:00

(GMT+09:00) Osaka, Sapporo, Tokyo

GMT+09:00

(GMT+09:00) Palau, Pyongyang, Seoul

GMT+09:30

(GMT+09:30) Adelaide, Broken Hill

GMT+09:30

(GMT+09:30) Darwin

GMT+10:00

(GMT+10:00) Brisbane, Port Moresby, Guam

GMT+10:00

(GMT+10:00) Canberra, Melbourne, Sydney

GMT+10:00

(GMT+10:00) Hobart

GMT+10:00

(GMT+10:00) Khabarovsk, Vladivostok

GMT+10:30

(GMT+10:30) Lord Howe Island

GMT+11:00

(GMT+11:00) Honiara, Magadan, Soloman Islands

GMT+11:00

(GMT+11:00) Noumea - New Caledonia

GMT+11:30

(GMT+11:30) Kingston - Norfolk Island

GMT+12:00

(GMT+12:00) Andyra, Kamchatka

GMT+12:00

(GMT+12:00) Auckland, Wellington

GMT+12:00

(GMT+12:00) Marshall Islands, Eniwetok

GMT+12:00

(GMT+12:00) Suva - Fiji

GMT+12:45

(GMT+12:45) Chatham Island

GMT+13:00

(GMT+13:00) Nuku'alofa - Tonga

GMT+13:00

(GMT+13:00) Rawaki, Phoenix Islands

GMT+14:00

(GMT+14:00) Line Islands, Kiritimati - Kiribati


C.3  CTC Default Settings

Table C-18 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following user-configurable defaults for CTC:

Automatic Routing—Set circuit creation with the Route Automatically check box selected by default.

Network Circuit Automatic Routing Overridable—Set by default whether or not a user creating circuits can change (override) the Automatic Circuit Routing setting (also provisionable as a default) in the CTC Circuit Routing Preferences area. When this default is set to TRUE it enables users to change whether or not Route Automatically is selected in the check box. When this default is set to FALSE it ensures that users cannot change the Route Automatically setting while creating circuits in CTC.


Note When the Route Automatically check box is not selectable (and is not checked) during circuit creation, the following automatic routing suboptions are also unavailable: Using Required Nodes/Spans, Review Route Before Creation, and VT-DS3 Mapped Conversion.


Create TL1-like—Set whether to create only TL1-like circuits; that is, instruct the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.

Local domain creation and viewing—Set whether domains that users create and view persist globally (all CTC sessions), or only locally (within the current CTC session).

Network Map—Set the default network map (which country's map is displayed in CTC network view).

Table C-18 CTC Default Settings 

Default Name
Default Value
Default Domain

CTC.circuits.CreateLikeTL1

FALSE

TRUE, FALSE

CTC.circuits.RouteAutomatically

TRUE

TRUE, FALSE

CTC.circuits.RouteAutomaticallyDefaultOverridable

TRUE

TRUE, FALSE

CTC.network.LocalDomainCreationAndViewing

FALSE

TRUE, FALSE

CTC.network.Map

United States

-none-, Germany, Japan, Netherlands, South Korea, United Kingdom, United States


C.4  ETSI Platform Defaults

The following sections give the NE defaults for the ONS 15454 ETSI platform. To see defaults for the ONS 15454 ANSI platform, see the "ANSI Platform Defaults" section.

C.4.1  ETSI Card Defaults

The tables in this section list the default settings for each DWDM, Transponder (TXP), Muxponder (MXP), or Ethernet card. Cisco provides several types of user-configurable defaults for Cisco ONS 15454 DWDM, TXP, MXP, and Ethernet cards. Types of card defaults can be broadly grouped by function, as outlined in the following subsections. For information about individual card settings, refer to the "Provision Transponder and Muxponder Cards" chapter, or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide.


Note The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual or the Cisco ONS 15454 SDH Reference Manual.


The following types of defaults are defined for DWDM, TXP, MXP, and Ethernet cards.

C.4.1.1  ETSI Configuration Defaults

Most card and port-level configuration defaults correspond to settings found in the CTC card-level Provisioning tabs.


Note The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OSCM, OSC-CSM, OPT-BST, OPT-BST-L, GE_XP, 10GE_XP, TXP, and MXP cards. For information on how ALS card settings achieve network level optical safety, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."


Configuration defaults that are reachable from the CTC card-level Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab):

Line—(GE_XP, 10GE_XP, TXP and MXP cards) Line-level configuration settings, including SONET, Wavelength Trunk, Trunk, Client, Distance Extension, and Enhanced FC/FICON ISL settings.


Note Some line configuration tabs, including Client, Distance Extension, and Enhanced FC/FICON ISL settings tabs, only appear in the card-level Provisioning > Line tab after a pluggable port module (PPM) is provisioned to a fibre channel payload type (port rate) for the particular card.


OTN—(GE_XP, 10GE_XP, MXP-2.5G-10E, MXP-2_5G-10G, MXP-MR-10DME, TXP-MR-10E, TXP-MR-10G, TXP-MR-2.5G, and TXPP-MR-2.5G cards) Optical transport network (OTN) line configuration settings.

Card—(See listed settings for applicable cards)

Card mode—MXPP-MR-2.5G and MXP-MR-2.5G (ESCON, FC_GE, or MIXED), GE_XP (20GE MXP, 10GE MXP, or L2 over DWDM) , and 10GE_XP (10GE TXP or L2 over DWDM)

Port range-level mode settings—MXP-MR-10DME cards only

Termination mode—TXP-MR-10E, MXP-2.5G-10E, MXP-2.5G-10G, TXPP_MR_2.5G, TXP_MR_10G, and TXP_MR_2.5G cards

AIS squelch settings—TXP-MR-10E and MXP-2.5G-10E cards

ALS (card-level Maintenance > ALS tab)—(OSC-CSM, OSCM, OPT-BST, OPT-BST-L, GE_XP, 10GE_XP, TXP, and MXP cards) ALS configuration defaults.


Note For further information about supported features on each card, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."


C.4.1.2  ETSI Threshold Defaults

Threshold default settings define the default cumulative values (thresholds) beyond which a threshold crossing alert (TCA) will be raised, making it possible to monitor the network and detect errors early.

Card threshold default settings are provided as follows:

PM thresholds—(OSCM, OSC-CSM, TXP and MXP cards) Expressed in counts or seconds; includes line and SDH thresholds.

Optical thresholds—(GE_XP, 10GE_XP, TXP, and MXP cards) Expressed in percentages or dBm; includes client and trunk optical thresholds.

OTN FEC thresholds (GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts; includes enhanced, standard, 1G Ethernet, 1G Fibre channel, 1G FICON, STM-1, STM-4, STM-16, 2G FICON, and 2G Fibre channel thresholds.

OTN G.709 thresholds (GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts or seconds; includes ITU-T G.709 PM and SM thresholds.

Threshold defaults are defined for near end and/or far end, at 15-minute and one-day intervals. Thresholds are further broken down by type, such as Multiplex Section, Regeneration Section, VC LO, MS, RS, or Path, for performance monitoring (PM) thresholds, and TCA (warning) or Alarm for physical thresholds. PM threshold types define the layer to which the threshold applies. Physical threshold types define the level of response expected when the threshold is crossed.


Note For full descriptions of the thresholds you can set for each card, see Chapter 17, "Performance Monitoring."



Note In R7.0.1, when LOS, LOS-P, or LOF alarms occur on TXP and MXP trunks, certain TCAs are suppressed. For details, see "Alarm and TCA Monitoring and Management."



Note For additional information regarding PM parameter threshold defaults as defined by Telcordia specifications, refer to Telcordia GR-820-CORE and GR-253-CORE.


C.4.1.3  ETSI Defaults by Card

In the tables that follow, card defaults are defined by the default name, its factory-configured value, and the domain of allowable values that you can assign to it.


Note Some default values, such as certain thresholds, are interdependent. Before changing a value, review the domain for that default and any other related defaults for potential dependencies.


C.4.1.3.1  ETSI MXP_2.5G_10E Card Default Settings

Table C-19 lists the MXP_2.5G_10E card default settings.

Table C-19 ETSI MXP_2.5G_10E Card Default Settings 

Default Name
Default Value
Default Domain

MXP-2_5G-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

MXP-2_5G-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

MXP-2_5G-10E.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-2_5G-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10E.config.client.TerminationMode

Transparent

Transparent, Regeneration Section

MXP-2_5G-10E.config.client.ppmPortAssignment

STM16

UNASSIGNED, STM16

MXP-2_5G-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.i1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.client.stm16.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10E.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping

ODU Multiplex

ODU Multiplex

MXP-2_5G-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced

MXP-2_5G-10E.otn.otnLines.G709OTN

Enable

Enable

MXP-2_5G-10E.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.BBE

21260 (count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.EB

21260 (count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.BBE

212600 (count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.EB

212600 (count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.EB

21260 (count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.EB

212600 (count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0 - 2151900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0 - 212371200

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0 - 206582400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.2  ETSI MXP_2.5G_10G Card Default Settings

Table C-20 lists the MXP_2.5G_10G card default settings.

Table C-20 ETSI MXP_2.5G_10G Card Default Settings 

Default Name
Default Value
Default Domain

MXP-2_5G-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-2_5G-10G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-2_5G-10G.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10G.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10G.config.client.TerminationMode

Transparent

Transparent, Multiplex Section

MXP-2_5G-10G.config.client.ppmPortAssignment

STM16

UNASSIGNED, STM16

MXP-2_5G-10G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.i1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.stm16.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-2_5G-10G.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

MXP-2_5G-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-2_5G-10G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.BBE

21260 (count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.EB

21260 (count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.BBE

212600 (count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.EB

212600 (count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.EB

21260 (count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.EB

212600 (count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0 - 2151900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0 - 212371200

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0 - 206582400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 7967700

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 764899200

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.3  ETSI MXP_MR_2.5G Card Default Settings

Table C-21 lists the MXP_MR_2.5G card default settings.

Table C-21 ETSI MXP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

MXP-MR-2_5G.config.card.Mode

FC_GE

FC_GE, MIXED, ESCON

MXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL when //.card.Mode FC_GE; UNASSIGNED, ONE_GE, ESCON, FC1G ISL, FICON1G ISL when //.card.Mode MIXED; UNASSIGNED, ESCON when //.card.Mode ESCON

MXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2 - 256

MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-MR-2_5G.config.trunk.SendDoNotUse

FALSE

TRUE, FALSE

MXP-MR-2_5G.config.trunk.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE

21260 (count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB

21260 (count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE

212600 (count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB

212600 (count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB

21260 (count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB

212600 (count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 2151900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 212371200

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 206582400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.4  ETSI MXPP_MR_2.5G Card Default Settings

Table C-22 lists the MXPP_MR_2.5G card default settings.

Table C-22 ETSI MXPP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

MXPP-MR-2_5G.config.card.Mode

FC_GE

FC_GE, MIXED, ESCON

MXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL when //.card.Mode FC_GE; UNASSIGNED, ONE_GE, ESCON, FC1G ISL, FICON1G ISL when //.card.Mode MIXED; UNASSIGNED, ESCON when //.card.Mode ESCON

MXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2 - 256

MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

MXPP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXPP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.mm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.15min.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighRxPower

-14.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.HighTxPower

-8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.1day.LowTxPower

-35.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighRxPower

-11.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.HighTxPower

-12.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.escon.sm.alarm.LowTxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE

21260 (count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB

21260 (count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE

212600 (count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB

212600 (count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB

21260 (count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB

212600 (count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 2151900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 212371200

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 206582400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.5  ETSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings

Table C-23 lists the MXP_MR_10DME_C and MXP_MR_10DME_L card default settings.

Table C-23 ETSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings 

Default Name
Default Value
Default Domain

MXP-MR-10DME.config.card.Mode

Port 1-8: FC_GE_ISC

Port 1-8: FC_GE_ISC, Port 1-4: FC_GE_ISC, Port 5-8: FC4G, Port 1-4: FC4G, Port 5-8: FC_GE_ISC, Port 1-8: FC4G

MXP-MR-10DME.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-10DME.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-10DME.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

MXP-MR-10DME.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE-GE, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC3 PEER 1G, ISC3 PEER 2G when //.card.Mode Port 1-8: FC_GE_ISC; UNASSIGNED, FC4G_PORT when //.card.Mode Port 1-8: FC4G; UNASSIGNED, ONE-GE, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, FC4G, ISC3 PEER 1G, ISC3 PEER 2G when //.card.Mode Port 1-4: FC_GE_ISC, Port 5-8: FC4G, Port 1-4: FC4G, Port 5-8: FC_GE_ISC

MXP-MR-10DME.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-10DME.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-10DME.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-10DME.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-10DME.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

MXP-MR-10DME.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

MXP-MR-10DME.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-10DME.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-MR-10DME.config.trunk.SendDoNotUse

FALSE

FALSE, TRUE

MXP-MR-10DME.config.trunk.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.1gisc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.2gisc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.mm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.HighTxPower

0.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gfibrechannel.sm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.LowRxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.mm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.15min.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.1day.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.HighTxPower

0.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.4gficon.sm.alarm.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.client.isc.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-10DME.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-10DME.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-MR-10DME.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-MR-10DME.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-MR-10DME.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-MR-10DME.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

MXP-MR-10DME.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

MXP-MR-10DME.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

MXP-MR-10DME.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

MXP-MR-10DME.otn.otnLines.AsynchSynchMapping

Synch Mapping

Synch Mapping

MXP-MR-10DME.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

MXP-MR-10DME.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-MR-10DME.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-10DME.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 7967700

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 764899200

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

MXP-MR-10DME.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.6  ETSI TXP_MR_10E Card Default Settings

Table C-24 lists the TXP_MR_10E card default settings.

Table C-24 ETSI TXP_MR_10E Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

TXP-MR-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

TXP-MR-10E.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

TXP-MR-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

TXP-MR-10E.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment UNASSIGNED, SONET; Transparent when ppmPortAssignment 10G Ethernet, 10G Fiber Channel

TXP-MR-10E.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, SDH, 10G Ethernet, 10G Fiber Channel

TXP-MR-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

6.0, 6.1, 6.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

TXP-MR-10E.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.er.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.ew.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lrm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.lw.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.sw.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gethernet.zr.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.mm.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.10gfibrechannel.sm.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.15min.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.15min.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.1day.HighRxPower

-1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.1day.LowRxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.alarm.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i1.alarm.LowRxPower

-13.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i1.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.i5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.i5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.15min.HighTxPower

8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.15min.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.1day.HighTxPower

8.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.1day.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l2.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l2.alarm.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.l5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.l5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.p1l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.s5.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.s5.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.client.stm64.v3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.client.stm64.v3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.enhancedfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.15min.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.1day.LowTxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10E.opticalthresholds.trunk.standardfec.alarm.LowTxPower

3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10E.otn.otnLines.AsynchSynchMapping

Synch Mapping

Asynch mapping, Synch Mapping

TXP-MR-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-10E.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10E.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.pmthresholds.client.ms.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.ms.farend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.ms.farend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0 - 7967700

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0 - 764899200

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 7967700

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 764899200

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.7  ETSI TXP_MR_10G Card Default Settings

Table C-25 lists the TXP_MR_10G card default settings.

Table C-25 ETSI TXP_MR_10G Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 300

TXP-MR-10G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when mrPortAssignment UNASSIGNED, SDH; Transparent when mrPortAssignment 10G Ethernet

TXP-MR-10G.config.client.mrPortAssignment

UNASSIGNED

UNASSIGNED, SDH, 10G Ethernet

TXP-MR-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-10G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.stm64.lw.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.stm64.lw.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-22.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.HighTxPower

7.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-1.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-10G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.pmthresholds.client.ms.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.client.ms.farend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.client.ms.farend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0 - 7967700

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0 - 764899200

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0 - 7967700

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0 - 764899200

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.8  ETSI TXP_MR_2.5G Card Default Settings

Table C-26 lists the TXP_MR_2.5G card default settings.

Table C-26 ETSI TXP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

TXP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-2_5G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment UNASSIGNED, STM1, STM4, STM16; Transparent when ppmPortAssignment STM1, STM4, STM16, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, STM1, STM4, STM16, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected

15012 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected

1441152 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected

225837 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected

21680352 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected

56457 (count)

0 - 9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected

5419872 (count)

0 - 867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-2_5G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE

1312 (count)

0 - 137700

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB

1312 (count)

0 - 137700

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE

13120 (count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB

13120 (count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE

1312 (count)

0 - 137700

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB

1312 (count)

0 - 137700

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE

13120 (count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB

13120 (count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE

10000 (count)

0 - 137700

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB

10000 (count)

0 - 138600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE

10000 (count)

0 - 13219200

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB

100000 (count)

0 - 13305600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE

21260 (count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB

21260 (count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE

212600 (count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB

212600 (count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB

21260 (count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB

212600 (count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB

10000 (count)

0 - 2151900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE

10000 (count)

0 - 212371200

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB

100000 (count)

0 - 206582400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE

5315 (count)

0 - 552600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB

5315 (count)

0 - 552600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE

53150 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB

53150 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE

5315 (count)

0 - 552600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB

5315 (count)

0 - 552600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE

53150 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB

53150 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE

10000 (count)

0 - 552600

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB

10000 (count)

0 - 2151900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE

10000 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB

100000 (count)

0 - 53136000

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.9  ETSI TXPP_MR_2.5G Card Default Settings

Table C-27 lists the TXPP_MR_2.5G card default settings.

Table C-27 ETSI TXPP_MR_2.5G Card Default Settings 

Default Name
Default Value
Default Domain

TXPP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXPP-MR-2_5G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment UNASSIGNED, STM1, STM4, STM16; Transparent when ppmPortAssignment STM1, STM4, STM16, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, STM1, STM4, STM16, ONE-GE, ESCON, DV6000, SDI-D1-VIDEO, HDTV, PASS-THRU, ETR-CLO, ISC COMPAT, FC1G, FC2G, FICON1G, FICON2G, ISC PEER

TXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60 - 300

TXPP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.cx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.dx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.hx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.t.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.vx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.1gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gfibrechannel.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowRxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.2gficon.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.dv6000.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.hdtv.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.mm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.isc3.sm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighRxPower

-4.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.ir2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.lr3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.sdid1video.sr1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.i1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighRxPower

-10.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm1.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.i1.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.HighTxPower

9.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.1day.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.LowRxPower

-29.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l2.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.15min.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.LowRxPower

-18.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.1day.LowTxPower

-11.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s1.alarm.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm16.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.cwdm.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.i1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.15min.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.1day.LowTxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.HighTxPower

-6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.LowRxPower

-31.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l1.alarm.LowTxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.l3.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s1.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.stm4.s2.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowRxPower

-24.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.2r.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowRxPower

-28.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.disabledfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighRxPower

-9.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.standardfec.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected

15012 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected

1441152 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected

225837 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected

21680352 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected

56457 (count)

0 - 9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords

1 (count)

0 - 4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected

5419872 (count)

0 - 867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords

96 (count)

0 - 453570969600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN Enable; Disable when G709OTN Disable

TXPP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXPP-MR-2_5G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE

1312 (count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB

1312 (count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE

13120 (count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB

13120 (count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE

1312 (count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB

1312 (count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE

13120 (count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB

13120 (count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE

10000 (count)

0 - 137700

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB

10000 (count)

0 - 138600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE

10000 (count)

0 - 13219200

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB

100000 (count)

0 - 13305600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE

21260 (count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB

21260 (count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE

212600 (count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB

212600 (count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE

21260 (count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB

21260 (count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE

212600 (count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB

212600 (count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE

10000 (count)

0 - 2212200

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB

10000 (count)

0 - 2151900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE

10000 (count)

0 - 212371200

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB

100000 (count)

0 - 206582400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE

5315 (count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB

5315 (count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE

53150 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB

53150 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE

5315 (count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB

5315 (count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES

87 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES

1 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE

53150 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB

53150 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES

864 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES

4 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE

10000 (count)

0 - 552600

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB

10000 (count)

0 - 2151900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES

500 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS

3 (seconds)

0 - 900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE

10000 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB

100000 (count)

0 - 53136000

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.10  ETSI GE_XP Card Default Settings

Table C-28 lists the GE_XP card default settings.

Table C-28 ETSI GE_XP Card Default Settings 

Default Name
Default Value
Default Domain

XP-GE.config.card.Mode

10GE MXP

20GE MXP, 10GE MXP, L2 over DWDM

XP-GE.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

XP-GE.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-GE.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

XP-GE.config.client.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-GE.config.client.FlowControl

OFF

OFF, ON

XP-GE.config.client.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-GE.config.client.Speed

Auto

1000 Mbps, Auto

XP-GE.config.client.cEtherType

8100 (Hex)

Free form field

XP-GE.config.client.macLearningState

OFF

OFF, ON

XP-GE.config.client.niMode

UNI MODE

UNI MODE, NNI MODE

XP-GE.config.client.sEtherType

8100 (Hex)

Free form field

XP-GE.config.client.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-GE.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

XP-GE.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-GE.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

XP-GE.config.trunk.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-GE.config.trunk.FlowControl

OFF

OFF, ON

XP-GE.config.trunk.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-GE.config.trunk.Speed

10000 Mbps

10000 Mbps

XP-GE.config.trunk.cEtherType

8100 (Hex)

Free form field

XP-GE.config.trunk.macLearningState

OFF

OFF, ON

XP-GE.config.trunk.niMode

NNI MODE

UNI MODE, NNI MODE

XP-GE.config.trunk.sEtherType

8100 (Hex)

Free form field

XP-GE.config.trunk.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.cwdm.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighRxPower

-3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.1day.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.HighTxPower

-1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.lx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.15min.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.15min.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.1day.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.1day.LowTxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.HighTxPower

-2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.sx.alarm.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.15min.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.1day.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighLaserBias

100.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighRxPower

30.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.LowRxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.client.1gethernet.zx.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-GE.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-GE.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-GE.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-GE.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-GE.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-GE.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-GE.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-GE.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-GE.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

XP-GE.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

XP-GE.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

XP-GE.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

XP-GE.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

XP-GE.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

XP-GE.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

XP-GE.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

XP-GE.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

XP-GE.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

XP-GE.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

XP-GE.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

XP-GE.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

XP-GE.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

XP-GE.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

XP-GE.otn.otnLines.G709OTN

Enable

Disable, Enable

XP-GE.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9


C.4.1.3.11  ETSI 10GE_XP Card Default Settings

Table C-29 lists the 10GE_XP card default settings.

Table C-29 ETSI 10GE_XP Card Default Settings 

Default Name
Default Value
Default Domain

XP-10GE.config.card.Mode

10GE TXP

10GE TXP, L2 over DWDM

XP-10GE.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

XP-10GE.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-10GE.config.client.AlsRecoveryPulseInterval

100 (seconds)

100 - 2000

XP-10GE.config.client.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-10GE.config.client.FlowControl

OFF

OFF, ON

XP-10GE.config.client.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-10GE.config.client.Speed

10000 Mbps

10000 Mbps

XP-10GE.config.client.cEtherType

8100 (Hex)

Free form field

XP-10GE.config.client.macLearningState

OFF

OFF, ON

XP-10GE.config.client.niMode

UNI MODE

UNI MODE, NNI MODE

XP-10GE.config.client.sEtherType

8100 (Hex)

Free form field

XP-10GE.config.client.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-10GE.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

XP-10GE.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test

XP-10GE.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200 - 2000

XP-10GE.config.trunk.CommittedInfoRate

100 (%)

0, 1, 2 .. 100

XP-10GE.config.trunk.FlowControl

OFF

OFF, ON

XP-10GE.config.trunk.MTU

1548 (max 9216)

64, 65, 66 .. 9216

XP-10GE.config.trunk.Speed

10000 Mbps

10000 Mbps

XP-10GE.config.trunk.cEtherType

8100 (Hex)

Free form field

XP-10GE.config.trunk.macLearningState

OFF

OFF, ON

XP-10GE.config.trunk.niMode

NNI MODE

UNI MODE, NNI MODE

XP-10GE.config.trunk.sEtherType

8100 (Hex)

Free form field

XP-10GE.config.trunk.sIngressCOS

0

0, 1, 2, 3, 4, 5, 6, 7, Trust

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.lr.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.15min.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighRxPower

0.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.LowRxPower

0.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.1day.LowTxPower

-6.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.LowRxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.client.10gethernet.zr.alarm.LowTxPower

-2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowRxPower

-23.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowRxPower

-26.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.disabledfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.enhancedfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.15min.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighRxPower

-7.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.HighTxPower

6.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowRxPower

-27.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.1day.LowTxPower

-4.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighRxPower

-5.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowRxPower

-30.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.dwdm.standardfec.alarm.LowTxPower

-3.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.lr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.15min.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.HighTxPower

5.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowRxPower

-14.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.1day.LowTxPower

-12.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

XP-10GE.opticalthresholds.trunk.10gethernet.zr.disabledfec.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

XP-10GE.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-10GE.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-10GE.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-10GE.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-10GE.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0 - 9033621811200

XP-10GE.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0 - 4724697600

XP-10GE.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0 - 867227693875200

XP-10GE.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0 - 453570969600

XP-10GE.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0 - 8850600

XP-10GE.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0 - 72

XP-10GE.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0 - 900

XP-10GE.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0 - 849657600

XP-10GE.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0 - 6912

XP-10GE.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0 - 86400

XP-10GE.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0 - 86400

XP-10GE.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN Enable; Disable when G709OTN Disable

XP-10GE.otn.otnLines.G709OTN

Enable

Disable, Enable

XP-10GE.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9


C.4.1.3.12  ETSI OSCM Card Default Settings

Table C-30 lists the OSCM card default settings.

Table C-30 ETSI OSCM Card Default Settings 

Default Name
Default Value
Default Domain

OSCM.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OSCM.pmthresholds.ms.farend.15min.BBE

1312 (count)

0 - 137700

OSCM.pmthresholds.ms.farend.15min.EB

1312 (count)

0 - 137700

OSCM.pmthresholds.ms.farend.15min.ES

87 (seconds)

0 - 900

OSCM.pmthresholds.ms.farend.15min.SES

1 (seconds)

0 - 900

OSCM.pmthresholds.ms.farend.15min.UAS

3 (seconds)

0 - 900

OSCM.pmthresholds.ms.farend.1day.BBE

13120 (count)

0 - 13219200

OSCM.pmthresholds.ms.farend.1day.EB

13120 (count)

0 - 13219200

OSCM.pmthresholds.ms.farend.1day.ES

864 (seconds)

0 - 86400

OSCM.pmthresholds.ms.farend.1day.SES

4 (seconds)

0 - 86400

OSCM.pmthresholds.ms.farend.1day.UAS

10 (seconds)

0 - 86400

OSCM.pmthresholds.ms.nearend.15min.BBE

1312 (count)

0 - 137700

OSCM.pmthresholds.ms.nearend.15min.EB

1312 (count)

0 - 137700

OSCM.pmthresholds.ms.nearend.15min.ES

87 (seconds)

0 - 900

OSCM.pmthresholds.ms.nearend.15min.SES

1 (seconds)

0 - 900

OSCM.pmthresholds.ms.nearend.15min.UAS

3 (seconds)

0 - 900

OSCM.pmthresholds.ms.nearend.1day.BBE

13120 (count)

0 - 13219200

OSCM.pmthresholds.ms.nearend.1day.EB

13120 (count)

0 - 13219200

OSCM.pmthresholds.ms.nearend.1day.ES

864 (seconds)

0 - 86400

OSCM.pmthresholds.ms.nearend.1day.SES

4 (seconds)

0 - 86400

OSCM.pmthresholds.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

OSCM.pmthresholds.rs.nearend.15min.BBE

10000 (count)

0 - 138600

OSCM.pmthresholds.rs.nearend.15min.EB

10000 (count)

0 - 138600

OSCM.pmthresholds.rs.nearend.15min.ES

500 (seconds)

0 - 900

OSCM.pmthresholds.rs.nearend.15min.OFS

500 (seconds)

0 - 900

OSCM.pmthresholds.rs.nearend.15min.SES

500 (seconds)

0 - 900

OSCM.pmthresholds.rs.nearend.15min.UAS

3 (seconds)

0 - 900

OSCM.pmthresholds.rs.nearend.1day.BBE

100000 (count)

0 - 13305600

OSCM.pmthresholds.rs.nearend.1day.EB

100000 (count)

0 - 13305600

OSCM.pmthresholds.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

OSCM.pmthresholds.rs.nearend.1day.OFS

5000 (seconds)

0 - 86400

OSCM.pmthresholds.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

OSCM.pmthresholds.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.13  ETSI OSC-CSM Card Default Settings

Table C-31 lists the OSC-CSM card default settings.

Table C-31 ETSI OSC-CSM Card Default Settings 

Default Name
Default Value
Default Domain

OSC_CSM.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OSC_CSM.pmthresholds.ms.farend.15min.BBE

1312 (count)

0 - 137700

OSC_CSM.pmthresholds.ms.farend.15min.EB

1312 (count)

0 - 137700

OSC_CSM.pmthresholds.ms.farend.15min.ES

87 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.farend.15min.SES

1 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.farend.15min.UAS

3 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.farend.1day.BBE

13120 (count)

0 - 13219200

OSC_CSM.pmthresholds.ms.farend.1day.EB

13120 (count)

0 - 13219200

OSC_CSM.pmthresholds.ms.farend.1day.ES

864 (seconds)

0 - 86400

OSC_CSM.pmthresholds.ms.farend.1day.SES

4 (seconds)

0 - 86400

OSC_CSM.pmthresholds.ms.farend.1day.UAS

10 (seconds)

0 - 86400

OSC_CSM.pmthresholds.ms.nearend.15min.BBE

1312 (count)

0 - 137700

OSC_CSM.pmthresholds.ms.nearend.15min.EB

1312 (count)

0 - 137700

OSC_CSM.pmthresholds.ms.nearend.15min.ES

87 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.nearend.15min.SES

1 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.nearend.15min.UAS

3 (seconds)

0 - 900

OSC_CSM.pmthresholds.ms.nearend.1day.BBE

13120 (count)

0 - 13219200

OSC_CSM.pmthresholds.ms.nearend.1day.EB

13120 (count)

0 - 13219200

OSC_CSM.pmthresholds.ms.nearend.1day.ES

864 (seconds)

0 - 86400

OSC_CSM.pmthresholds.ms.nearend.1day.SES

4 (seconds)

0 - 86400

OSC_CSM.pmthresholds.ms.nearend.1day.UAS

10 (seconds)

0 - 86400

OSC_CSM.pmthresholds.rs.nearend.15min.BBE

10000 (count)

0 - 138600

OSC_CSM.pmthresholds.rs.nearend.15min.EB

10000 (count)

0 - 138600

OSC_CSM.pmthresholds.rs.nearend.15min.ES

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.rs.nearend.15min.OFS

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.rs.nearend.15min.SES

500 (seconds)

0 - 900

OSC_CSM.pmthresholds.rs.nearend.15min.UAS

3 (seconds)

0 - 900

OSC_CSM.pmthresholds.rs.nearend.1day.BBE

100000 (count)

0 - 13305600

OSC_CSM.pmthresholds.rs.nearend.1day.EB

100000 (count)

0 - 13305600

OSC_CSM.pmthresholds.rs.nearend.1day.ES

5000 (seconds)

0 - 86400

OSC_CSM.pmthresholds.rs.nearend.1day.OFS

5000 (seconds)

0 - 86400

OSC_CSM.pmthresholds.rs.nearend.1day.SES

5000 (seconds)

0 - 86400

OSC_CSM.pmthresholds.rs.nearend.1day.UAS

10 (seconds)

0 - 86400


C.4.1.3.14  ETSI Amplifier Card Default Settings

Table C-32 lists the OPT-BST and OPT-BST-L card default settings.

Table C-32 ETSI Amplifier Card Default Settings 

Default Name
Default Value
Default Domain

OPT-AMP-17-C.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OPT-BST-L.config.card.AlsMode

Auto Restart

Disabled, Auto Restart

OPT-BST.config.card.AlsMode

Auto Restart

Disabled, Auto Restart


C.4.2  ETSI Node Default Settings

Table C-33 lists the Cisco ONS 15454 node-level default settings for the ETSI shelf assembly. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:

Circuit settings—Set the administrative state, subnetwork connection protection (SNCP) circuit threshold levels for signal degradation and failure, SNCP reversion time, and whether SNCP circuits are revertive by default.

General settings—Set general node management defaults, including whether to use Daylight Savings Time (DST), the IP address of the NTP/SNTP server to be used, the time zone where the node is located, the SD path BER value, whether automatic autonomous TL1 reporting of PM data is enabled for cross-connect paths on the node, whether or not to allow ports to be disabled when they are providing services (when the default is set to FALSE users must remove or disable the services first, then put the ports out of service), and the defaults description.

Link Management Protocol settings—Set link management protocol data link type, traffic engineering link, and general settings.

Power Monitor settings—Set default voltage thresholds for the node.

Network settings—Set whether to prevent display of node IP addresses in CTC (applicable for all users except Superusers); default gateway node type; whether to raise an alarm when the backplane LAN cable is disconnected; and whether to display the IP address in the LCD in an editable mode (in which you can change the IP address directly from LCD screen), to display the IP address on the LCD as read-only, or to suppress display of the IP on the LCD entirely.

OSI settings—Set the Open System Interconnection (OSI) main setup, generic routing encapsulation (GRE) tunnel default, the link access protocol on the D channel (LAP-D), the router subnet, and the TID address resolution protocol (TARP) settings.

Linear Multiplex Section Protection (LMSP) settings—Set whether or not protected circuits have bidirectional switching, are revertive, and what the reversion time is.

MS-SPRing protection settings—Set whether MS-SPRing-protected circuits are revertive, and what the reversion time is, at both the ring and span levels.

Y Cable protection settings—Set whether Y-cable protected circuits are revertive, and what the reversion time is.

Splitter protection settings—Set whether splitter protected circuits are revertive, and what the reversion time is.

Legal Disclaimer—Set the legal disclaimer that warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.

Security Grant Permissions—Set default user security levels for activating/reverting software, PM data clearing, database restoring, and retrieving audit logs.

Security DataComm settings—Set default security settings for TCC Ethernet IP address and IP netmask, and CTC backplane IP suppression; set secure mode on and secure mode locked (for TCC2P cards only).

Security Access settings—Set default security settings for LAN access, shell access, serial craft access, element management system (EMS) access (including Internet Inter-Object Request Broker Protocol [IIOP] listener port number), TL1 access, and SNMP access.

Security RADIUS settings—Set default RADIUS server settings for the accounting port number and the authentication port number, and whether to enable the node as a final authenticator.

Security Policy settings—Set the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference that is required between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.

Security Password settings—Set when passwords can be changed, how many characters they must differ by, whether or not password reuse is allowed, and whether a password change is required on first login to a new account; set password aging enforcement and user-level specific aging and warning periods; set how many consecutive identical characters are allowed in a password, maximum password length, minimum password length, minimum number and combination of nonalphabetical characters required, and whether or not to allow a password that is a reversal of the login ID associated with the password.

BITS Timing settings—Set the AIS threshold, Admin synchronization status messaging (SSM), coding, facility type, framing, state, and Sa bit (the overhead bit that will carry the SSM) for building integrated timing supply 1 (BITS-1) and BITS2 timing.

General Timing settings—Set the mode (External, Line, or Mixed), revertive, and reversion time.


Note For more information about each individual node setting, refer to the "Manage the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide.



Note Refer to the CTC Default Settings for CTC-level default settings for the Cisco ONS 15454.


Table C-33 ETSI Node Default Settings 

Default Name
Default Value
Default Domain

NODE.circuits.State

unlocked, automaticInService

unlocked, locked, disabled, locked, maintenance, unlocked, automaticInService

NODE.circuits.sncp.HO_SDBER

1E-6

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.circuits.sncp.HO_SFBER

1E-4

1E-3, 1E-4, 1E-5

NODE.circuits.sncp.LO_SDBER

1E-6

1E-5, 1E-6, 1E-7, 1E-8

NODE.circuits.sncp.LO_SFBER

1E-4

1E-3, 1E-4, 1E-5

NODE.circuits.sncp.ProvisionWorkingGoAndReturnOnPrimaryPath

FALSE

TRUE, FALSE

NODE.circuits.sncp.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.circuits.sncp.Revertive

FALSE

TRUE, FALSE

NODE.general.AllowServiceAffectingPortChangeToDisabled

TRUE

FALSE, TRUE

NODE.general.AutoPM

FALSE

FALSE, TRUE

NODE.general.DefaultsDescription

Factory Defaults

Free form field

NODE.general.NtpSntpServer

0.0.0.0

IP Address

NODE.general.ReportLoopbackConditionsOnUnlocked,MaintenancePorts

FALSE

FALSE, TRUE

NODE.general.TimeZone

(GMT-08:00) Pacific Time (US & Canada), Tijuana

(For applicable time zones, see Table C-17.)

NODE.general.UseDST

TRUE

TRUE, FALSE

NODE.lmp.controlChannel.AdminState

locked, disabled

unlocked, locked, disabled

NODE.lmp.controlChannel.HelloDeadInterval

12000 (ms)

maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)), maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 1, maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 2 .. minimum_of(20000,MaxHelloDeadInterval)

NODE.lmp.controlChannel.HelloInterval

500 (ms)

maximum_of(300,MinHelloInterval), maximum_of(300,MinHelloInterval) + 1, maximum_of(300,MinHelloInterval) + 2 .. minimum_of(5000,MaxHelloInterval,quotient_of(HelloDeadInterval,3))

NODE.lmp.controlChannel.MaxHelloDeadInterval

20000 (ms)

maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)), maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 1, maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 2 .. 20000

NODE.lmp.controlChannel.MaxHelloInterval

2000 (ms)

maximum_of(300,HelloInterval), maximum_of(300,HelloInterval) + 1, maximum_of(300,HelloInterval) + 2 .. minimum_of(5000,difference_of(MaxHelloDeadInterval,1))

NODE.lmp.controlChannel.MinHelloDeadInterval

2000 (ms)

maximum_of(2000,sum_of(MinHelloInterval,1)), maximum_of(2000,sum_of(MinHelloInterval,1)) + 1, maximum_of(2000,sum_of(MinHelloInterval,1)) + 2 .. minimum_of(20000,HelloDeadInterval)

NODE.lmp.controlChannel.MinHelloInterval

300 (ms)

300, 301, 302 .. minimum_of(5000,HelloInterval,difference_of(MinHelloDeadInterval,1))

NODE.lmp.dataLink.Type

Port

Port, Component

NODE.lmp.general.Allowed

TRUE

FALSE, TRUE

NODE.lmp.general.Enabled

FALSE

FALSE, TRUE when Allowed TRUE; FALSE when Allowed FALSE

NODE.lmp.general.LMP-WDM

TRUE

FALSE, TRUE

NODE.lmp.general.Role

OLS

PEER, OLS

NODE.lmp.teLink.AdminState

locked, disabled

unlocked, locked, disabled

NODE.lmp.teLink.DWDM

TRUE

FALSE, TRUE

NODE.lmp.teLink.MuxCapability

Lambda Switch

Packet Switch - Level 1, Packet Switch - Level 2, Packet Switch - Level 3, Packet Switch - Level 4, Layer 2 Switch, TDM Cross-connect, Lambda Switch, Fiber Switch

NODE.network.general.AlarmMissingBackplaneLAN

FALSE

TRUE, FALSE

NODE.network.general.CtcIpDisplaySuppression

FALSE

TRUE, FALSE

NODE.network.general.GatewaySettings

None

LeaveAsIs, None, ENE, GNE, ProxyOnlyNode

NODE.network.general.LcdSetting

Allow Configuration

Allow Configuration, Display Only, Suppress Display

NODE.osi.greTunnel.OspfCost

110

110 - 65535

NODE.osi.greTunnel.SubnetMask

24 (bits)

8, 9, 10 .. 32

NODE.osi.lapd.MTU

512

512, 513, 514 .. 1500

NODE.osi.lapd.Mode

AITS

AITS, UITS

NODE.osi.lapd.Role

Network

Network, User

NODE.osi.lapd.T200

200 (ms)

200, 300, 400 .. 20000

NODE.osi.lapd.T203

10000 (ms)

4000, 4100, 4200 .. 120000

NODE.osi.mainSetup.L1L2LSPBufferSize

512 (bytes)

512 - 1500

NODE.osi.mainSetup.L1LSPBufferSize

512 (bytes)

512 - 1500

NODE.osi.mainSetup.NodeRoutingMode

Intermediate System Level 1

End System, Intermediate System Level 1, Intermediate System Level 1/Level 2

NODE.osi.subnet.DISPriority

63

1, 2, 3 .. 127

NODE.osi.subnet.ESH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.GCCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.IIH

3 (sec)

1, 2, 3 .. 600

NODE.osi.subnet.ISH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.LANISISCost

20

1, 2, 3 .. 63

NODE.osi.subnet.LDCCISISCost

40

1, 2, 3 .. 63

NODE.osi.subnet.OSCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.SDCCISISCost

60

1, 2, 3 .. 63

NODE.osi.tarp.L1DataCache

TRUE

FALSE, TRUE

NODE.osi.tarp.L2DataCache

FALSE

FALSE, TRUE

NODE.osi.tarp.LANStormSuppression

TRUE

FALSE, TRUE

NODE.osi.tarp.LDB

TRUE

FALSE, TRUE

NODE.osi.tarp.LDBEntry

5 (min)

1 - 10

NODE.osi.tarp.LDBFlush

5 (min)

0 - 1440

NODE.osi.tarp.PDUsL1Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsL2Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsOrigination

TRUE

FALSE, TRUE

NODE.osi.tarp.T1Timer

15 (sec)

0 - 3600

NODE.osi.tarp.T2Timer

25 (sec)

0 - 3600

NODE.osi.tarp.T3Timer

40 (sec)

0 - 3600

NODE.osi.tarp.T4Timer

20 (sec)

0 - 3600

NODE.osi.tarp.Type4PDUDelay

0 (sec)

0 - 255

NODE.powerMonitor.EHIBATVG_48V

-56.5 (Vdc)

-40.5, -41.0, -41.5 .. -57.0

NODE.powerMonitor.EHIBATVG_60V

-72.0 (Vdc)

-50.0, -50.5, -51.0 .. -72.0

NODE.powerMonitor.ELWBATVG_48V

-40.5 (Vdc)

-40.5, -41.0, -41.5 .. -56.5

NODE.powerMonitor.ELWBATVG_60V

-50.0 (Vdc)

-50.0, -50.5, -51.0 .. -72.0

NODE.protection.lmsp.BidirectionalSwitching

FALSE

TRUE, FALSE

NODE.protection.lmsp.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.lmsp.Revertive

FALSE

TRUE, FALSE

NODE.protection.msspr.RingReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.msspr.RingRevertive

TRUE

TRUE, FALSE

NODE.protection.msspr.SpanReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.msspr.SpanRevertive

TRUE

TRUE, FALSE

NODE.protection.splitter.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.splitter.Revertive

FALSE

TRUE, FALSE

NODE.protection.ycable.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.ycable.Revertive

FALSE

TRUE, FALSE

NODE.security.dataComm.CtcBackplaneIpDisplaySuppression

TRUE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.DefaultTCCEthernetIP

10.0.0.1

IP Address

NODE.security.dataComm.DefaultTCCEthernetIPNetmask

24 (bits)

8, 9, 10 .. 32

NODE.security.dataComm.LcdBackplaneIpSetting

Display Only

Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.SecureModeLocked

FALSE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.SecureModeOn (May reboot node)

FALSE

FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE

NODE.security.dataComm.isSecureModeSupportedOnControlCard

TRUE

FALSE, TRUE

NODE.security.emsAccess.AccessState

NonSecure

NonSecure, Secure

NODE.security.emsAccess.IIOPListenerPort (May reboot node)

57790 (port #)

0 - 65535

NODE.security.grantPermission.ActivateRevertSoftware

Superuser

Provisioning, Superuser

NODE.security.grantPermission.PMClearingPrivilege

Provisioning

Provisioning, Superuser

NODE.security.grantPermission.RestoreDB

Superuser

Provisioning, Superuser

NODE.security.grantPermission.RetrieveAuditLog

Superuser

Provisioning, Superuser

NODE.security.idleUserTimeout.Maintenance

01:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Provisioning

00:30 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Retrieve

00:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Superuser

00:15 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.lanAccess.LANAccess (May disconnect CTC from node)

Front & Backplane

No LAN Access, Front Only, Backplane Only, Front & Backplane

NODE.security.lanAccess.RestoreTimeout

5 (minutes)

0 - 60

NODE.security.legalDisclaimer.LoginWarningMessage

<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.

Free form field

NODE.security.other.DisableInactiveUser

FALSE

FALSE, TRUE

NODE.security.other.InactiveDuration

45 (days)

1, 2, 3 .. 99 when nothing TRUE; 45 when nothing FALSE

NODE.security.other.SingleSessionPerUser

FALSE

TRUE, FALSE

NODE.security.passwordAging.EnforcePasswordAging

FALSE

TRUE, FALSE

NODE.security.passwordAging.maintenance.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.maintenance.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.provisioning.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.provisioning.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.retrieve.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.retrieve.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordAging.superuser.AgingPeriod

45 (days)

20 - 90

NODE.security.passwordAging.superuser.WarningPeriod

5 (days)

2 - 20

NODE.security.passwordChange.CannotChangeNewPassword

FALSE

TRUE, FALSE

NODE.security.passwordChange.CannotChangeNewPasswordForNDays

20 (days)

20 - 95

NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters

1 (characters)

1 - 5

NODE.security.passwordChange.PreventReusingLastNPasswords

1 (times)

1 - 10

NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount

FALSE

TRUE, FALSE

NODE.security.passwordComplexity.IdenticalConsecutiveCharactersAllowed

3 or more

0-2, 3 or more

NODE.security.passwordComplexity.MaximumLength

20

20, 80

NODE.security.passwordComplexity.MinimumLength

6

6, 8, 10, 12

NODE.security.passwordComplexity.MinimumRequiredCharacters

1 num, 1 letter & 1 TL1 special

1 num, 1 letter & 1 TL1 special, 1 num, 1 letter & 1 special, 2 each of any 2 of num, upper, lower & TL1 special, 2 each of any 2 of num, upper, lower & special

NODE.security.passwordComplexity.ReverseUserIdAllowed

TRUE

TRUE, FALSE

NODE.security.radiusServer.AccountingPort

1813 (port)

0 - 32767

NODE.security.radiusServer.AuthenticationPort

1812 (port)

0 - 32767

NODE.security.radiusServer.EnableNodeAsFinalAuthenticator

TRUE

FALSE, TRUE

NODE.security.serialCraftAccess.EnableCraftPort

TRUE

TRUE, FALSE

NODE.security.shellAccess.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.shellAccess.EnableShellPassword

FALSE

TRUE, FALSE

NODE.security.shellAccess.TelnetPort

23

23 - 9999

NODE.security.snmpAccess.AccessState

NonSecure

Disabled, NonSecure

NODE.security.tl1Access.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.userLockout.FailedLoginsAllowedBeforeLockout

5 (times)

0 - 10

NODE.security.userLockout.LockoutDuration

00:30 (mins:secs)

00:00, 00:05, 00:10 .. 10:00

NODE.security.userLockout.ManualUnlockBySuperuser

FALSE

TRUE, FALSE

NODE.software.AllowDelayedUpgrades

FALSE

FALSE, TRUE

NODE.software.DefaultDelayedUpgrades

FALSE

FALSE, TRUE when AllowDelayedUpgrades TRUE; FALSE when AllowDelayedUpgrades FALSE

NODE.timing.bits-1.AISThreshold

DUS

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-1.AdminSSMIn

STU

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-1.Coding

HDB3

HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz

NODE.timing.bits-1.CodingOut

HDB3

HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz

NODE.timing.bits-1.FacilityType

E1

E1, 64kHz+8kHz, 2MHz

NODE.timing.bits-1.FacilityTypeOut

E1

E1, 6MHz, 2MHz

NODE.timing.bits-1.Framing

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityType 64kHz+8kHz

NODE.timing.bits-1.FramingOut

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityTypeOut 6MHz

NODE.timing.bits-1.Sa bit

4

4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-1.State

unlocked

unlocked, locked, disabled

NODE.timing.bits-1.StateOut

unlocked

unlocked, locked, disabled

NODE.timing.bits-2.AISThreshold

DUS

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-2.AdminSSMIn

STU

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-2.Coding

HDB3

HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz

NODE.timing.bits-2.CodingOut

HDB3

HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz

NODE.timing.bits-2.FacilityType

E1

E1, 64kHz+8kHz, 2MHz

NODE.timing.bits-2.FacilityTypeOut

E1

E1, 6MHz, 2MHz

NODE.timing.bits-2.Framing

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityType 64kHz+8kHz

NODE.timing.bits-2.FramingOut

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityTypeOut 6MHz

NODE.timing.bits-2.Sa bit

4

4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz

NODE.timing.bits-2.State

unlocked

unlocked, locked, disabled

NODE.timing.bits-2.StateOut

unlocked

unlocked, locked, disabled

NODE.timing.general.Mode

External

External, Line, Mixed

NODE.timing.general.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.timing.general.Revertive

FALSE

TRUE, FALSE



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Jul 9 12:52:08 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.