LightStream 1010 ATM Switch DS3 and E3 Port Adapter Module Configuration Note

LightStream 1010 ATM Switch DS3 and E3 Port Adapter Module Configuration Note

Product Numbers: WAI-T3-2BNC=, WAI-E3-2BNC=

This document contains instructions for installing and configuring the DS3 and E3 port modules. For a complete description of commands used to configure and maintain the DS3 and E3 port adapter modules, refer to the LightStream 1010 ATM Switch Software Configuration Guide and the LightStream 1010 ATM Switch Command Reference publications. For complete hardware configuration and maintenance procedures, refer to the LightStream 1010 ATM Switch User Guide publication.

Cisco documentation and additional literature are available on a CD called Cisco Connection Documentation, Enterprise Series. The CD is updated and shipped monthly, so it might be more up-to-date than the printed documentation. To order the Cisco Connection Documentation, Enterprise Series CD, contact your local sales representative or call Customer Service. The CD is available both as a single CD and as an annual subscription. You can access Cisco technical documentation on the World Wide Web Universal Resources Locator (URL) http://www.cisco.com.

Sections in this document include the following:

Warning Only trained and qualified personnel should install or replace the LightStream 1010 ATM switch, chassis, power supplies, fan assembly, or modules.

What is the LightStream 1010 ATM Switch?

The LightStream 1010 uses a five-slot, modular chassis featuring the option of dual, fault-tolerant, load-sharing power supplies. (See Figure 1.) The central slot in the LightStream 1010 is dedicated to a single, field-replaceable ATM switch processor (ASP) module that supports both the 5-Gbps shared memory and the fully nonblocking switch fabric. The ASP also supports the feature card and high performance reduced instruction set (RISC) processor that provides the central intelligence for the device. The remaining slots support up to four hot-swappable Carrier Modules (CAMs). Each CAM supports up to two hot-swappable Port Adapter Modules (PAMs) for a maximum of eight PAMs per switch, supporting a wide variety of desktop, backbone, and wide-area interfaces.


Figure 1: Front View of the LightStream 1010 ATM Switch


The LightStream 1010 ATM switch provides switched ATM connections to individual workstations, servers, LAN segments, or other ATM switches and routers using fiber-optic, unshielded twisted-pair (UTP), and coaxial cable.

The LightStream 1010 ATM switch can accommodate up to 8 DS3 and E3 port adapter modules in a standard 19-inch (48-centimeter) rack.

Figure 2 shows an example of a network configuration using the LightStream 1010 ATM switch in a high-performance workgroup.


Figure 2: LightStream 1010 Workgroup Configuration Example


Figure 3 shows an example of a network configuration using the LightStream 1010 ATM switch for a campus backbone.


Figure 3: LightStream 1010 Backbone Configuration Example


DS3 and E3 Port Adaptor Module Description

This section describes the DS3 and E3 PAMs.

DS3 Port Adapter Module

The DS3 PAM, shown in Figure 4, provides connection to two DS3 interfaces using four BNC coaxial connectors.


Figure 4: DS3 Port Adapter Module

E3 Port Adapter Module

The E3 PAM, shown in Figure 5, provides connection to two E3 interfaces using four BNC coaxial connectors.


Figure 5: E3 Port Adapter Module

Specifications

Table 1 lists the module specifications for the DS3 and E3 port adaptor modules.


Table 1: DS3 and E3 Module Specifications
Description Specifications

Dimensions (H x W x D)

PAM: 1.2 x 6.5 x 10 in. (3.0 x 16.5 x 25.4 cm)

Weight

1.10 lb (.50 kg)

Operating temperature

32 to 104° F (0 to 40° C)

Nonoperating temperature

-40 to 167° F (-40 to 75° C)

Humidity

10 to 90%, noncondensing

Altitude

-500 to 10,000 ft (-52 to 3,048 m)

Interface timing

Loop timing, Stratum 4 accuracy clock for self-timing

Port adapter modules (PAM)

PAM with 2 DS3 ports, BNC connectors (WAI-T3-2BNC)
PAM with 2 E3 ports, BNC connectors (WAI-E3-2BMC)

Network management

Port Tx and Rx LEDs, switch and common equipment status LEDs

Mean Time Between Failures

2.6 years for system configuration

Management Information Bases (MIB)

DS-3 and E3 MIB (RFC 1407)

Maximum
station-to-station cabling distance

DS3---coaxial cable: 450 ft (137 m)
E3---coaxial cable: 450 ft (137 m)

Agency approvals

Safety: UL1 1950, CSA2-C22.2 No. 950-93, and EN60950
EMI3: FCC Class A
CE Mark, and VCCI Class II with shielded cables

1UL = Underwriters Laboratory
2CSA = Canadian Standards Association
3EMI = electromagnetic interference

Maximum Configuration

The four available CAMs support any combination of network interfaces to provide the following maximum port densities:

You can install any combination of PAMs in any of the eight available PAM slots. There are no restrictions on either the number of modules that can be installed or their proximity to the ASP.

Module LEDs

This section describes the DS-3 PAM LEDs.

DS3 LEDs

The LEDs on the DS3 PAM provide status information for the module and individual BNC coaxial interface connections. The LEDs are shown in Figure 6 and described in Table 2.


Figure 6: DS3 Port Adapter Module LEDs

Table 2:
DS3 Port Adapter Module LED  Descriptions
LED Description

RX (Receive)

Off---No signal received.
Flashing green---Cells being received: blinks every five seconds and pulse rate increases with data rate.
Red---Alarm (LOF1, LCD2, AIS3).

TX (Transmit)

Off---Not transmitting.
Flashing green---Cells being transmitted:  pulse rate increases with data rate.
Flashing yellow---Loopback.
Steady yellow---Alarm FERF4.

1LOF = loss of frame
2LCD = loss of cell delineation
3AIS = alarm indication signal
4FERF = far-end receive failure

E3 LEDs

The LEDs on the E3 PAM provide status information for the module and individual E3 coaxial interface connections. The LEDs are shown in Figure 7 and described in Table 3.


Figure 7: E3 Port Adapter Module LEDs

Table 3:
E3 Port Adapter Module LED  Descriptions
LED Description

RX (Receive)

Off---No signal received.
Flashing green---Cells being received: blinks every five seconds and pulse rate increases with data rate.
Red---Alarm (LOF1, LCD2, AIS3).

TX (Transmit)

Off---Not transmitting.
Flashing green---Cells being transmitted: pulse rate increases with data rate.
Flashing yellow---Loopback.
Steady yellow---Alarm FERF4.

1LOF = loss of frame
2LCD = loss of cell delineation
3AIS = alarm indication signal
4FERF = far-end receive failure

Preparing Network Connections

When preparing your site for network connections to the switch, you need to consider a number of factors related to each type of interface:

Distance Limitations

The length of your networks and the distances between connections depend on the type of signal, the signal speed, and the transmission media (the type of cabling used to transmit the signals). For example, fiber-optic cable has a greater channel capacity than twisted-pair cabling. The following distance limits are provided as guidelines for planning your network connections before installation.

ATM Connections

The maximum distances for ATM network segments and connections depend on the type of transmission cable used, for example, unshielded twisted-pair (UTP), single-mode, or multimode fiber-optic cable.

Networking standards set the maximum distances between stations using coaxial cable. The maximum cable lengths are listed in Table 4.


Table 4: ATM Maximum Transmission Distances
Transceiver Speed Cable Type Maximum Distance between Stations

45 Mbps

Coaxial cable

450 feet (137 meters)

34 Mbps

Coaxial cable

450 feet (137 meters)

For Further Reference

The following publications contain information on determining attenuation and power budget:

Additional and Optional Connection Equipment

To install and configure the switch, you need a terminal with an EIA/TIA-232 data terminal equipment (DTE) port and an EIA/TIA-232 data communications equipment (DCE) console cable with DB-25 plugs at one end. You can detach the terminal (and cable) after the installation and configuration procedures are complete.

ATM Connection Equipment

For DS3 and E3 connections, use the 75-ohm, RG-59, coaxial cable (see Figure 8), which has bayonet-style, twist-lock (BNC) connectors to connect the DS3 PAM and E3 PAM with the external ATM switch.


Figure 8: Coaxial Interface Cable and BNC Connectors

ATM Coaxial Connections

All coaxial ATM interfaces are full-duplex. You must use the appropriate ATM interface cable to connect the ATM PAM with an external ATM network.

The ATM PAM provides an interface to ATM switching fabrics for transmitting and receiving data at 34 and 45 Mbps bidirectionally.

The ATM PAM can support interfaces that connect to the following physical layers:

Connect the ATM interface cables as shown in Figure 9. For detailed descriptions of ATM cabling requirements, refer to the section"Distance Limitations" and the section in the chapter "Preparing for Installation" in the LightStream 1010 ATM Switch User Guide.


Figure 9: ATM Coaxial Connections

Safety Recommendations

The following guidelines helps ensure your safety and protect the equipment. This list is not inclusive of all potentially hazardous situations you may be exposed to as you install the module, so be alert.

Warning Metal objects heat up when connected to power and ground, and can cause serious burns.

Safety with Electricity

The supervisor engine, modules, and redundant power supplies are designed to be removed and replaced while the system is operating without presenting an electrical hazard or damage to the system. Before removing a redundant power supply, make sure the first supply is powered on. You must shut down the system before removing or replacing any of the replaceable components inside the front panel, for example, the backplane. Never install equipment that appears damaged.

Follow these basic guidelines when working with any electrical equipment:

In addition, use the following guidelines when working with equipment that is disconnected from a power source but still connected to telephone wiring or other network cabling.

Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) damage, which occurs when electronic cards or components are improperly handled, can result in complete or intermittent failures. Each PAM consist of a printed circuit card that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding, connectors, and a handle are integral components of the carrier. Although the metal carrier helps to protect the cards from ESD, use a preventive antistatic strap whenever you handle the PAMs. Handle the carriers by the handles and the carrier edges only; never touch the cards or connector pins.

Caution Always tighten the captive installation screws on the PAM when you are installing them. These screws prevent accidental removal of the CAMs and PAMs, provide proper grounding for the system, and help to ensure that the bus connectors are properly seated in the backplane.

Following are guidelines for preventing ESD damage:


Figure 10: Placement of Electrostatic Discharge Wrist Strap


Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohms (Mohms).

Installing and Replacing PAMs

All PAMs support hot-swapping, which allows you to install, remove, replace, and rearrange the PAMs without turning off the system power. When the system detects that a PAM has been installed or removed, it automatically runs diagnostic and discovery routines, acknowledges the presence or absence of the PAM, and resumes system operation without any operator intervention.

Caution The ASP is a required system component. Removing an ASP while the system is operating will cause the system to shut down and may damage the processor.

What is Hot-Swapping?

The hot-swap feature allows you to remove and replace modules while the system is operating; you do not need to notify the software or shut down the system power. All CAMs and PAMs (except for the ASP) support hot-swapping.

Each CAM contains a bus-type connector that mates with the system backplane. Each card connector consists of a set of tiered pins, in three lengths. The pins send specific signals to the system as they make contact with the backplane. The system assesses the signals it receives and the order in which it receives them to determine what event is occurring and what task it needs to perform, such as reinitializing new interfaces or shutting down removed ones.

For example, when inserting a CAM, the longest pins make contact with the backplane first, and the shortest pins make contact last. The system recognizes the signals and the sequence in which it receives them. The system expects to receive signals from the individual pins in this logical sequence, and the ejector levers help to ensure that the pins mate in this sequence.

When you remove or insert a PAM, the backplane pins send signals to notify the system, which then performs as follows:

    1. Rapidly scans the backplane for configuration changes.

    2. Initializes all newly inserted PAMs, noting any removed interfaces and placing them in the administratively shutdown state.

    3. Brings all previously configured interfaces on the PAM back to the state they were in when they were removed. If a PAM, similar to the one that was removed, has been reinserted into a slot, then its ports are configured and brought online up to the port count of the original PAM.

Hot-swap functionality enables you to add, remove, or replace PAMs with the system online, which provides a seamless method to users on the network, maintains all routing information, and ensures session preservation.

When you insert a new PAM, the system runs a diagnostic test on the new interfaces and compares them to the existing configuration. If this initial diagnostic fails, the system remains offline for another 15  seconds while it performs a second set of diagnostic tests to determine whether or not the PAM is faulty and if normal system operation is possible.

If the second diagnostic test passes, which indicates that the system is operating normally and the new PAM is faulty, the system resumes normal operation but leaves the new interfaces disabled.

If the second diagnostic test fails, the system crashes, which usually indicates that the new PAM has created a problem in the bus and should be removed.

Caution To avoid erroneous failure messages, allow at least 15  seconds for the system to reinitialize and note the current configuration of all interfaces before you remove or insert another PAM.

Tools Required

You need a 3/16-inch flat-blade screwdriver to remove any filler (blank) PAMs and to tighten the captive installation screws that secure the CAMs and PAMs in their slots. Whenever you handle CAMs and PAMs, you should use a wrist strap or other grounding device to prevent electrostatic discharge (ESD) damage. See the section "Preventing Electrostatic Discharge Damage" in the chapter "Preparing for Installation" in the LightStream 1010 ATM Switch User Guide.

Installing CAMs or PAMs

You can install CAMs in any of the four CAM slots numbered 0 through 4 from top to bottom when viewing the chassis from the front as shown in Figure 11. (The middle slot (number 2) contains the ASP, which is a required system component.) Blank CAM and PAM fillers are installed in CAMs or PAM slots without CAMs or PAMs to maintain consistent airflow through the module compartment. Refer to the LightStream 1010 ATM Switch User Guide for information about installing the CAM.


Figure 11: Slot Numbers

Following are detailed steps for removing PAMs and successfully performing hot-swap. Figure 11 shows the ejector levers, which you must use when inserting or removing the CAMs.

Caution Handle PAMs by the carrier edges only to prevent ESD damage.

Step 1 Choose a PAM slot (shown in Figure 12) in a CAM and make sure there is enough clearance to accommodate any interface equipment you connect directly to the PAM ports. If possible, place PAMs between empty slots that contain only PAM filler plates.


Figure 12: PAM Slot Numbers

Step 2 PAMs are secured with one captive installation screw in the center of the faceplate. Use a 1/4-inch flat-blade screwdriver to loosen the captive installation screw and remove the PAM filler (or the existing PAM) from the PAM slot you want to use.

Step 3 Place the back of the PAM in the slot and align the notch on the sides of the module carrier with the groove in the slot. (See Figure 13.)

Step 4 Hold the PAM by both sides and guide it into the slot. Avoid touching the PAM's components.


Figure 13: PAM Carrier Installation

Step 5 Keep the PAM at a 90-degree orientation to the backplane, carefully slide the PAM into the slot until the faceplate makes contact with the CAM faceplate.

Step 6 Tighten the captive installation screw in the center of the PAM faceplate, using a 1/4-inch flat-blade screwdriver, and draw the PAM into the CAM connector until the PAM faceplate is flush with the CAM faceplate and the PAM is fully seated in the connector. (See Figure 13.)


Note Always use the captive screw to install or remove PAMs. A module that is partially seated in the CAM connector causes the system to halt and subsequently crash.

Step 7 Attach network interface cables or other devices to the interface ports.

Step 8 Check the status of the interfaces as follows:

Caution All PAMs support hot-swapping. The ASP is a required system component. Removing an ASP while the system is operating will cause the system to shut down.

Sample Screen Display for Hot-Swapping Procedure

When you remove and replace CAMs and PAMs, the system provides status messages on the console screen. The messages are for information only. In the following sample display, you can follow the events logged by the system when a PAM was removed from slot  3/0. When the PAM is reinserted, the system marks the module as ready again.

Switch# %OIR-6-REMCARD: Card removed from slot 3/0, interfaces disabled %LINK-5-CHANGED: Interface 155UTP 3/0, changed state to administratively down %LINK-5-CHANGED: Interface 155UTP 3/0, changed state to administratively down Switch# %OIR-6-INSCARD: Card inserted in slot 3/0, interfaces administratively shut down %LINK-5-CHANGED: Interface 155UTP 3/0, changed state to up %LINK-5-CHANGED: Interface 155UTP 3/0, changed state to up

Port Adapter Module Configurations

The PAMs support different media and interface types. The configuration commands used with these different PAMs vary according to PAM type. For complete PAM configuration information, refer to the publications LightStream 1010 ATM Switch Software Configuration Guide and LightStream 1010 ATM Switch Command Reference.

Configuring the Interfaces

After you install the module, use the following information to configure the module and the individual interfaces on the DS-3 and E3 port adaptor modules. In the LightStream 1010 ATM Switch User Guide the section "LightStream 1010 ATM Switch Hardware" contains an overview of the port and module numbering scheme used to configure the DS-3 and E3 PAMs. The section "Configuring the LightStream 1010 ATM Switch" describes how to configure the ports on the FDDI or CDDI module. The section "Confirming the Installation" describes the procedures you should use to confirm that the DS-3 and E3 PAMs are configured correctly.

Port Addresses

Each interface (or port) in the switch is designated by several different types of addresses. The physical interface address is the actual physical location (card/subcard/port) of the interface connector within the chassis. The system software uses the physical addresses to control activity within the switch and to display status information. These physical card/subcard/port addresses are not used by other devices in the network; they are specific to the individual switch and its internal components and software.

The following sections describe how the LightStream  1010 switch assigns and controls both the physical (card/subcard/port) and Media Access Control (MAC)-layer addresses for interfaces within the chassis.

Port IDs

In the LightStream  1010 switch, port IDs specify the actual physical location of each PAM port on the front of the switch. (See Figure 14.) The address is composed of a three-part number in the format card/subcard/port. The first number identifies the slot in which the module is installed. Module slots are numbered 0 to 4 from top to bottom. The second number identifies the subcard or PAM number. The PAMs are numbered 0 and 1 with 0 being the left PAM facing the front of the switch. The third number identifies the physical port number on the module. The port numbers always begin at 0 and are numbered from the left port to the right port, facing the front of the switch. The number of additional ports (/1, /2, and so on) depends on the number of ports available on the module.

Interface ports maintain the same port ID regardless of whether other modules are installed or removed. However, when you move a module to a different slot, the first number in the address changes to reflect the new slot number. For example, on a 4-port 155 UTP PAM in chassis slot 1 in PAM slot 0, the address of the left port is 1/0/0 and the address of the right port is 1/0/3. If you remove the 4-port 155 UTP PAM from slot 1 and install it in slot 4, the addresses of those same ports become 4/0/0 and 4/0/3.


Figure 14: ATM Interface Port ID Address Examples

You can identify module ports by physically checking the card/subcard/port location on the front of the switch. You can also use software commands to display information about a specific interface, or all interfaces, in the switch. To display information about every interface, use the show interface command without parameters. To display information about a specific interface, use the show interface command with the interface type and port address in the format show interface atm card/subcard/port. This command is described in the LightStream 1010 ATM Switch Command Reference publication.

DS3 and E3 Configuration Defaults

When the switch is powered on initially without any previous configuration data, the ATM interfaces are configured automatically on the physical ports. ILMI and the physical card type are used to automatically derive the ATM interface type, UNI version, maximum VPI and VCI bits, ATM interface side, and ATM UNI type.

Default ATM Interface Configuration Without Autoconfiguration

If ILMI has been disabled or if the connecting end node does not support ILMI, the following defaults are assigned to all interfaces:

The following PAM types have specific defaults assigned:

DS3 PAM:

E3 PAM:

You can accept the default ATM interface configuration or overwrite the default interface configuration using the command line interface commands. These commands are described in the section "Configuring Virtual Connections" in the LightStream 1010 ATM Switch Software Configuration Guide.




1Instructions for initial interface configurations are in the publication LightStream 1010 ATM Switch Software Configuration Guide.