Common Equipment Description

Common Equipment Description

This chapter provides a description of the common equipment hardware modules that make up
the MGX 8220 shelf Release 3.0. The optional service modules are described in Chapter 4,
"Cisco MGX 8220 Service Modules".

The common equipment of the MGX 8220 shelf consists of the following modules:

System Overview

The MGX 8220 shelf is a 19 inch rack mountable shelf which provides 16 slots for holding the modules (card sets) that provide the MGX 8220 shelf functionality. Each slot is designed to house two cards; a front card and a back card. Cards are installed in a slot as a two card set referred to as a module. A backplane runs across all 16 slots which provides signal connections between front and back cards and between slots. The backplane also provides power distribution to all slots from dual (redundant) power entry modules installed in the bottom of the shelf.

All external line connections (for example, Frame Relay lines, the ATM trunk line and control console RS-232 lines) are made on the back cards at the rear of the shelf.

A cooling assembly containing the MGX 8220 cooling fans consists of a rack mounted fan unit below the main MGX 8220 shelf and either a plenum or spacer unit which is mounted above the shelves. The cooling assembly is capable of cooling up to two MGX 8220 shelves in the same rack. In racks that contain more than two shelves, a booster cooling unit is used to provide additional cooling. The cooling assembly is powered from the main MGX 8220 shelf. An external view of a single MGX 8220 shelf configuration is shown in Figure 2-1. The arrangement of assemblies in a rack including cases for multiple MGX 8220 shelves is provided in Chapter 6,
"Installation and Start-up".


Figure 2-1: MGX 8220 Shelf Configuration

An MGX 8220 shelf consists of various kinds of modules with each module consisting of a larger front card function module which provides the functionality of the module and a smaller back card which provides the connectors and interfaces for the external lines that the module supports.

The MGX 8220 Shelf Controller (ASC) is the module that provides the overall control of the shelf. Each MGX 8220 shelf must have at least one ASC and may be configured with a second (redundant) ASC.

The ASC back card also provides the RS-232 ports and Ethernet port for attaching a control terminal or workstation.

The Broadband Network Module (BNM) provides the interface to the BPX network over a T3 or E3 line using the ATM STI protocol. Each MGX 8220 shelf must have at least one BNM and may be configured with a second (redundant) BNM. The BNM also provides:

The Service Resource Module (SRM) communicates with all service modules over a Bit Error Rate Test (BERT) bus and provides the capability for testing T1 and E1 and subrate service module lines. The SRM can set up loopback configurations and generate test bit patterns for any user specified Nx64 kbps port. The SRM can also provide 1:N redundancy for FRSM, AUSM, and CESM cards. The SRM is an optional card.


Note The ASC and the BNM together are referred to as the core modules and at least one set must be installed in the shelf. If redundancy is required, BOTH the ASC and the BNM must be configured with redundant cards. If configured, the SRM is also part of the core modules. Failure of an ASC or BNM will cause switchover to the redundant ASC, BNM and SRM cards. Failure of the active SRM card will only cause switchover if the SRM is included in the redundant set as well.

The Service Modules provide the customer interfaces. In Release 3.0, up to ten service modules may be configured in a shelf. Service modules may be intermixed in the same shelf.

The overall operation of the shelf is to:

The Inverse Multiplexing for ATM Trunk Module (IMATM), an extension to the BPX BNI card, is housed in the MGX 8220 shelf in a service module slot and supports BPX ATM trunks over multiple (up to 8) T1 and E1 lines instead of single T3 or E3 line. The IMATM does not use the
MGX 8220 cellbus as other service modules do, but provides its own trunk to the BPX.

In performing these functions, the MGX 8220 shelf collects a wide variety of statistics about frames and cells, error conditions, congestion, and so forth.

A simplified block diagram of the MGX 8220 hardware is shown in Figure 2-2. As shown by the dashed lines, the ASC, SRM and Cellbus are all 1 for 1 redundant with one ASC, BNM, SRM slot set attached to one Cellbus, and the remaining ASC, BNM, and SRM slot set tied to the other Cellbus.


Figure 2-2: The MGX 8220 Shelf Top Level Block Diagram

Traffic Management

Traffic management is provided by the MGX 8220 Connection Congestion Management (ACCM) feature. This feature is a virtual source/virtual destination rate based closed loop feedback scheme between nodes based upon ForeSight® and the ATM Forum Available Rate specification. Periodically the round trip delay (RTD) of a cell to the far end and back is calculated for each actual connection. The RTD is used to determine how frequently ForeSight rate adjustment cells are sent to the far end. Based upon available bandwidth and current access rate, every few microseconds a ForeSight cell is transmitted to the far end with any rate adjustments that may be necessary to make better use of the available bandwidth (rate is adjusted up, down or fast down). The MIB includes rate (MIR, PIR, and QIR) and adjustments (Up%, Down%, and Fast-Down%) objects.

ATM Local Management Interface (ATM LMI)

A Local Management Interface (ATM LMI) operates between the MGX 8220 shelf and the BPX switch. The ATM LMI is used to communicate change of status of semipermanent connections. The ATM LMI protocol conforms with that specified in ITU-TS Recommendation Q.2931, Sept. 1994. The ATM LMI also supports optional proprietary extensions to the ATM LMI for the reporting of node information and BNI queue configurations.

The two end points of the ATM LMI signaling are an ATM LMI process in the BCC in the BPX switch and an ATM LMI process in the ASC in the MGX 8220 shelf. The ATM LMI PDUs are transported over an AAL5 connection (VPI=3/VCI=31) between the BNI on the BPX switch side and the BNM on the MGX 8220 shelf side. The ATM LMI process in the BPX switch can support ATM LMI connections for up to 16 MGX 8220 shelves.

The ATM LMI extension (which must be specifically enabled) uses a Node Update Status Message which is sent (BPX switch to the MGX 8220 shelf or the MGX 8220 shelf to BPX switch) whenever a change in Node Name, Node IP Address, Major Alarm Status, or Minor Alarm Status occurs. The message may optionally contain Qbin Status thereby allowing the MGX 8220 shelf to configure the BNI port egress queues.

Auto Card Restore

Auto Card Restore is a feature which allows a service module card to be removed and be hot plug replaced with another service module card keeping the same configuration. With this feature, the ASC maintains a copy of the configuration for each active service module.

MGX 8220 Shelf Hardware

The MGX 8220 shelf is a 19 inch rack mountable unit conforming to the EIA RS-310-C standard and measuring:

The shelf contains a card cage with 16 slots, the slots are numbered 1 to 16 from the left looking at the front of the shelf.

A backplane runs across the card cage spanning all 16 slots. The backplane is positioned approximately 14inches from the front of the cage allowing a function module card to be inserted in the slot from the front and a smaller line module card to be inserted in the slot from the rear.

Slots 1 and 2 are reserved for BNM cards (single or a redundant pair) and slots 3 and 4 are reserved for ASC cards (single or a redundant pair). Slots 15 and 16 are reserved for the SRM (single or redundant pair). Slots 1, 3, and 15 work together as an active or standby set, the same is true for slots 2, 4 and 16. Slots 5 through 14 (10 slots) are available for Service Modules (or IMATMs). For 1:N redundancy of T1/E1 service modules, standby cards must use slots 12, 13, and 14.

The shelf may house redundant power entry modules which are small cards installed horizontally in the bottom rear of the shelf. The MGX 8220 shelf is powered by -48VDC power sources (single or redundant pair). Each power entry module is equipped with a circuit breaker. The shelf also provides a power receptacle for a cable to the cooling assembly which is mounted in the rack below the
MGX 8220 shelf (or shelves).

The backplane provides redundant system buses for communication between slots, power distribution to all slots and communication between front and back cards. Figure 2-3 and Figure 2-4 show the front and rear views of the MGX 8220 shelf.


Figure 2-3: Front View of the MGX 8220 Shelf with Cards Installed

Figure 2-4:
Rear View of the MGX 8220 Shelf

MGX 8220 Backplane

The MGX 8220 backplane contains a main system bus, the cell bus, for communication between card slots. The cell bus consists of two pairs of unidirectional buses (for redundancy) which are used for transferring cells between the cell bus slave modules (FRSM, AUSM, ASC) and the cellbus master (BNM).

The backplane also contains a local bus which permits the ASC to configure and monitor the BNM and SRM, a BERT bus for bit error rate testing, and a Redundancy bus for support of 1:N service module redundancy.

The backplane distributes -48VDC power to all card slots and all modules are hot insertable.

Typical MGX 8220 Hardware Weights

Hardware Weight (lbs)

MGX 8220 shelf with 16 boards

68

MGX 8220 main cooling unit

20

MGX 8220 booster cooling unit

14

MGX 8220 plenum

8

Average single MGX 8220 board

1.9

Power Entry Options

DC Powered Systems

In DC powered systems the MGX 8220 shelf supports one or two power entry modules (PEMs) each which can be connected to its own independent 48VDC supply. The power entry modules are installed horizontally, side by side in the bottom rear of the shelf. (See Figure 2-4.) Each module is powered from a 48 VDC power source via three wires:

The 48VDC cable is connected to the power entry module through a 3- position EURO Block connector. The two modules provide power supply redundancy, each power entry module is capable of supplying enough power for a fully loaded MGX 8220 shelf.

An illustration of a power entry module is shown in Figure 2-5.


Figure 2-5: MGX 8220 Power Entry Module

Each power entry module contains its own circuit breaker which also acts as an ON/OFF switch. The circuit breaker is closed by pressing in the large black button until it latches in the closed position. The circuit breaker is opened by pressing the smaller red button. The DC PEM also includes a bracket which is attached to the PEM to provide cable strain relief. See Chapter 6,
"Installation and Start-up" for details.

AC Powered Systems

In AC powered systems, a separate AC power assembly is required. (See Figure 2-6 and Figure 2-7.) This assembly is rack mounted under the shelf cooling assembly in the rack and is available in both a single and double AC source line version. The power assembly has a modular design and can be configured with up to 6 power supply modules, each module providing 875 watts of 48VDC power. The power assembly can provide power for up to four MGX 8220 shelves, requiring 3 power supply modules, or four for a (1 for N) redundant power supply configuration. The rear panel has four connectors which supply 48VDC power to the shelves. The first three (1A, 2A, and 3A) connectors also provide power monitoring information to the MGX 8220 shelf. Another 3 connectors (1B, 2B, and 3B) on the rear panel provide monitoring information for the second half of the power supply. Special cables are used from the rear of the power assembly to the rear of the shelves to feed power and monitor data to the shelves.

The AC power assembly measures:


Figure 2-6: AC Power Assembly (front w/o grill)

Figure 2-7:
AC Power Assembly (rear)

DC Power Drain and Circuit Protection

Each card in an MGX 8220 shelf draws an average of 21 watts with a worst case shelf current of 14.40 amps.

The circuit breaker in the DC Power Entry Module (PEM) is rated at 15.00 amps.

The MGX 8220 circuits are protected as follows:

Each MGX 8220 board is equipped with a DC/DC converter (Shindengen-HGG05006 or
AT&T-JW030A) which has automatic current limiting to 5 volts output.

A schematic of the DC power system is shown in Figure 2-8.


Figure 2-8: DC Power System

Cooling Assemblies

The MGX 8220 cooling assembly consists of multiple rack-mounted units.

Main Cooling Assembly

The main cooling assembly measures:

The main cooling assembly is capable of providing cooling for up to two MGX 8220 shelves and is mounted in the rack below the shelf (or shelves). The cooling assembly consists of fans which draw air through a filter at the front and exhaust air upwards through the shelf. An illustration of the cooling assembly is shown in Figure 2-9.


Figure 2-9: Cooling Assembly

Booster Cooling Assembly

The booster cooling assembly measures:

The booster cooling assembly is used in racks with more than two MGX 8220 shelves and is mounted above the shelves cooled by the main cooling assembly and below the shelves to which the booster cooling is to be provided. The booster cooling assembly consists of fans which draw air from the shelves below and exhaust air upwards through the shelf or shelves above. Each booster supports an additional two MGX 8220 shelves. A system of up to six MGX 8220 shelves can be supported (using one main cooling unit and two booster cooling units).

Cooling Assembly Power

For both cooling assemblies, power is supplied to the connector at the rear of the cooling assembly by a cable running from the connector in the middle bottom rear of the MGX 8220 shelf.

The assemblies provide output signals to the shelf. The performance of the cooling assemblies can be monitored by the BNM cards. The cable delivering DC power to the cooling assembly from the MGX 8220 shelf also carries these signals to the BNM via the backplane.The model of the cooling assembly can be identified and the speed of each fan can be monitored (each fan generates a fixed number of square-wave pulses per revolution allowing the speed of the fan to be determined).

The Plenum Exhaust Chamber

The Plenum chamber measures:

The exhaust plenum chamber is used in normal UL compliant installations where the top of the unit must be enclosed. The plenum chamber is mounted in the rack immediately above the shelf (shelves). The chamber delivers air from the shelf below out to the rear of the rack. The plenum chamber is preferred.

Spacer Unit

The spacer unit measures:

If used, the spacer unit is mounted in the rack immediately above the shelf (shelves).

The plenum chamber and spacer units are alternative methods for exhausting the cooling air from the rack. Either method can be used but not both. The spacer does NOT support the attachment of a cable management kit.

Optional Cabinet

A cabinet is available from Cisco which can be used to install the MGX 8220 shelf, INS, the BPX switch, and the IGX switch equipment. Cisco systems preconfigured in a cabinet can be ordered from Cisco.

The cabinet is essentially a 19 inch rack with panels on all sides (including top and bottom) except the front. (See Figure 2-10.) The rear panel is a louvered hinged door. The cabinet is equipped with casters, brakes and leveling bolts. The cabinet also includes earthquake safety holes so that the cabinet can be secured to the floor using studs.

The vertical height of the cabinet (including casters) is 80.31inches providing 71.81inches (41 rack mounting units) of vertical rack space.

The cabinet is 23 inches wide and 36 inches deep. Since MGX 8220 modules are typically 22" deep, the cabinet provides approximately 12" of space behind the mounted MGX 8220 modules for cables and cable management hardware.

Modules are installed in the cabinet in the same manner as installed in a 19 inch rack. Modules are installed by inserting them into the front of the cabinet and attaching them to the internal racks. All cables are connected through the rear door.


Figure 2-10: MGX 8220 Cabinet

MGX 8220 Shelf Controller

The MGX 8220 Shelf Controller (ASC) is a two-card set consisting of an ASC front card and an ASC-BC back card. The shelf may contain a single ASC card set or a dual (redundant) card set. The cards are installed in slots three and/or four. An illustration of the ASC card set is provided in Figure 2-11.

The function of the ASC is to provide a user interface to provide overall control, configuration and management of the shelf. The ASC interfaces with the other cards in the shelf through the cell bus on the one side and with the user through console ports on the other side.


Figure 2-11: ASC Cards

Console Ports

There are three ASC hardware console ports all located on the faceplate of the back card.

Some Ethernet transceivers with integrated DB-15 connectors cannot be connected directly to the LAN AUI Ethernet port on the MGX 8220 ASC back card because of interference with the ASC back card extractor levers. To overcome this problem, two Ethernet transceiver extenders (one each for a primary and secondary ASC card) are provided.

If you encounter difficulty in connecting an Ethernet transceiver, install an extender on each ASC card as follows:

    1. With the retaining clip on the LAN AUI port in the unlocked (up) position, connect the Ethernet transceiver extender to the LAN AUI port on the ASC back card as shown in Figure 2-12.

    2. Push the port retaining clip into the locked (down) position to secure the connection.

    3. With the retaining clip on the transceiver extender in the unlocked (up) position, connect the Ethernet transceiver to the extender as shown in the diagram.

    4. Push the extender retaining clip into the locked (down) position to secure the connection.


Figure 2-12: Ethernet Extender

Note Additional access for shelf management is available through in-band communication over the ATM trunk.

ASC LED Indicators

The ASC has the following LED indicators, all located on the faceplate of the front card.

ACTIVE (ACT) LED Green:

STANDBY (STBY) LED Yellow:

FAIL (FAIL) LED Red:

LAN (LAN) LED Green:

Broadband Network Module

The Broadband Network Module (BNM) is a two-card set consisting of a BNM-T3 or E3 front card and a T3E3-D-BC or T3E3-B-BC back card. Either back card can be used with either front card except that the BNC clock connector only works for E1 clock sources. The shelf may contain a single BNM card set or a dual (redundant) card set. The cards are installed in slots 1 and/or 2.

An illustration of the BNM card set is provided in Figure 2-13.


Figure 2-13: BNM Cards

The major function of the BNM is to provide a T3 or E3 ATM interface to an BNI card in a BPX node. The BNM also provides a number of miscellaneous functions as follows:

ATM Trunk Interface

The BNM card accepts and transmits ATM cells over a T3 or E3 line interfaces at 44.736 Mbps or 33.368 Mbps respectively, asynchronously using the Cisco STI (StrataCom Trunk Interface) protocol.

Framing occurs on the card using C-bit parity. An 8Khz clock is extracted from the received signal and can be used to synchronize the entire MGX 8220 system.

The physical T3 or E3 ATM interface to the BNM is achieved via the BNM backcard. This physical connection is made with BNC connectors. There also exists relays on the backcard. These relays provide the continuity or discontinuity between the internal circuitry and the external BNC connectors for the Transmit and Receive lines.

These relays are also used as a mechanical loopback for the T3 or E3 bit stream.

The MGX 8220 shelf implements the ATM STI cell format by using slot/channel numbers in the VPI/VCI fields in the cell format used between the BNM and the BPX BNI port. The cell format is shown in Figure 2-14 and Figure 2-15. The format on the left is the general STI format, the format on the right is the MGX 8220 shelf implementation.

In this format, the virtual circuit is defined by:

The CC/FFCI/Supv. field is used for ForeSight bits and a Supervisory bit.


Figure 2-14: Release 3.0 MGX 8220 ATM Trunk Cell Format

Figure 2-15:
CC, FFCI, EFCI, Supv, PTI, and CLP fields

LED Indicators

The BNM has the following LED indicators, all located on the faceplate of the front card.

ACTIVE (ACT) LED Green:

STANDBY (STBY) LED Yellow:

FAIL (FAIL) LED Red:

PORT (PORT) LED Green, Red or Yellow:

MAJOR (MAJ) ALARM LED Red:

MINOR (MIN) ALARM LED Red:

DC OK A (DC-A) LED Green:

DC OK B (DC-B) LED Green:

ACO (ACO) LED Yellow:

HISTORY (HIST) LED Green:

Push Buttons

The BNM has two push-buttons located on the faceplate of the front card.

  The ACO button is a momentary switch and is depressed during a major or minor alarm to deactivate the audible alarm relays and to turn the ACO LED on. Any new alarm will cause the relays to be reactivated.
  The History Clear button is a momentary switch and is depressed to extinguish the History LED if there is no active alarm at the time.

Service Resource Module

The Service Resource Module (SRM-T1E1) is a front card with no back card. The shelf may contain one SRM card in slot 15 or 16 or a dual (redundant) card set occupying slots 15 and 16. The SRM is hot insertable.

An Illustration of the SRM-T1E1 card is provided in Figure 2-16.


Figure 2-16: SRM Card

The SRM card serves two major functions for service modules. It provides for bit error rate testing (BERT) of T1 and E1 lines and ports and it provides 1for N redundancy (requires license).

  BERT is capable of generating a variety of test patterns including all ones, all zeros, alternate one zero, double alternate one zero, 223-1, 220-1, 215-1, 211-1, and 29-1.
  1:N redundancy must be configured by the user. When the failure of an active card in a group is detected by the ASC, the SRM is ordered to invoke 1:N redundancy for that group. The back card of the failed service module now directs data to and from the standby service module. Once
1:N redundancy is invoked for a group, it is not available to the other groups or to other service modules in the group using 1:N redundancy; another failure in any group results in a shelf alarm.
  When the failed card is replaced, switch back to normal operation must be made by the user (it is not automatic).

LED Indicators

The SRM has the following LED indicators, all located on the faceplate of the front card.

ACTIVE (ACT) LED Green:

STANDBY (STBY) LED Yellow:

FAIL (FAIL) LED Red:

LINE REDUNDANCY (LINE RED) LED Red:

BERT (BERT) LED Green: