cc/td/doc/product/voice/c_callmg
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Application Note

Integration Description

Network Topology

Limitations

Calling Name and Number Feature

System Components

Cisco Hardware and Software Requirements

PBX Hardware and Software Requirements

Features

Configuration

Configuration Sequence and Tasks

Configuration Menus and Commands

Test Configuration

Layer 1 (Physical Layer)

Layers 2 & 3 (Q.921 and Q.931)

User/Network Settings

Test Results

PBX1 configured as ETSI (emulate Network) and Cisco 6608-E1 Gateway configured as PRI EURO (emulate User).

Ericsson MD-110 Switch-type/ Protocol side setting
Cisco 6608-E1 ISDN protocol-type/Protocol side setting

ETSI/Network

PRI EURO/User


Basic Calls: (Enbloc Sending)

Calls Made
Call Comp?
"Calling Number" Passed to Final Destination?
"Calling Name" Passed to Final Destination?
"Called Number" Passed to Orig. Side?
"Called Name" Passed to Orig. Side?
Notes

Phone A to Phone C

Yes

Yes

No

No1

No

2

Phone C to Phone A

Yes

Yes

No

Yes

No

 

1 CallManager is not sending "Connected Number" information in the connect message back to PBX.

2 Calling Name delivery and presentation features are not supported by the Ericsson ISDN PRI Link.


Call Transfers: (Supervised Local Transfers)

Calls Made
Call Comp?
Orig. "Calling Number" displayed on Final Dest. phone?
Orig. "Calling Name" displayed on Final Dest. phone?
"Called Number" display on Orig. phone updated after transfer?
"Called Name" display on Orig. phone updated after transfer?
Notes

Phone C to Phone A Xfr to Phone B

Yes

Yes

No

No

No

 

Phone A to Phone C Xfr to Phone D

Yes

Yes

No

No

No

 

Call Conferencing (Local)

Calls Made
Call Comp?
"Calling Number" passed to remaining conferee when the conferencing phone drops out?
"Calling Name" passed to remaining conferee when the conferencing phone drops out?
"Connected Number" updated on Orig. Caller phone display when a conferee drops out?
"Connected Name" updated on Orig. Caller phone display when a conferee drops out?
Notes

Phone C to Phone A,

Phone A conf Phone B

Yes

(A Drops out)

Yes

(A Drops out)

No

(A Drops out)

No

(A Drops out)

No

 

Phone C to Phone A,

Phone C conf Phone D

Yes

(C Drops out)

No

(C Drops out)

No

(D Drops out)

No

(D Drops out)

No

 

Phone A to Phone C,

Phone C conf Phone D

Yes

(C Drops out)

No

(C Drops out)

No

(C Drops out)

No

(C Drops out)

No

 

Phone A to Phone C,

Phone A conf Phone B

Yes

(A Drops out)

No

(A Drops out)

No

(B Drops out)

No

(B Drops out)

No

 

Call Forward (Local)

Calls Made
Call Comp?
Original "Calling Number" passed to Final Dest.?
Original "Calling Name" passed to Final Dest.?
Forwarding "Called Number" passed to Final Dest.?
Forwarding "Called Name" passed to Final Dest.?
Final dest. "Connected Number" updated at orig. side?
Final dest. "Connected Name" updated at orig. side?
Notes

Phone C to Phone A fwd to Phone B

Yes

Yes

No

Yes

No

No

No

 

Phone A to Phone C fwd to Phone D

Yes

Yes

No

No

No

No

No

 

Appendix

Ericsson MD-110 Software Version

Catalyst 6000 Switch Configuration


Application Note


Ericsson MD-110 PBX with CallManager using 6608-E1 PRI EURO Gateway

Integration Description

Connectivity is achieved by using the ETSI standard PRI protocol. The Ericsson MD-110 can be configured as either NETWORK or USER side.

Network Topology

Figure 1 Network Topology or Test Setup

Limitations

Calling Name and Number Feature

Calling Name delivery and presentation features are not supported by the Ericsson MD-110 PBX.

When calling from Cisco 7960 IP phone to Ericsson digital phone, Calling/Called Number is displayed on both phones after the call is answered as expected.

When calling from Ericsson digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Ericsson phone however does NOT get updated when the call is answered. It displays the trunk name. It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.

System Components

Cisco Hardware and Software Requirements

Hardware (Gateway): 6608 E1 Port

Software: CallManager Release 3.1

PBX Hardware and Software Requirements

Hardware: TLU76/1

Software: Version BC9

Features

Calling/Called Number

Configuration

Configuration Sequence and Tasks

Configure in the following sequence:


Step 1. ROCAI Route Category Initiate

Setup internal characteristics for the route. Ex. Traffic direction, services, Bearer capabilities.
<_ROCAP:ROU=20;
ROUTE CATEGORY DATA

ROU SEL TRM SERV NODG DIST DISL TRAF SIG BCAP

20 711000000000 7 3110000010 0 5 20 03151515 211100000031 111111

END

Step 2. RODAI Route Data Initiate

E1-PRI Route Protocol Characteristics, protocol side "User"

<_RODAP:ROU=20;
ROUTE DATA

ROU TYPE VARC VARI VARO FILTER

20 SL60 H'00000010 H'05400000 H'06110000 NO

END
E1-PRI Route Protocol Characteristics, protocol side "Network"

<_RODAP:ROU=20;
ROUTE DATA

ROU TYPE VARC VARI VARO FILTER

20 SL60 H'00000010 H'05400000 H'06310000 NO

END

Step 3. ROEQI Route Equipment Initiate

E1-PRI trunk lines (B-channels)

<_ROEDP:ROU=20,TRU=ALL;
ROUTE EQUIPMENT DATA

ROU TRU EQU SQU INDDAT


20 001-1 001-1-40-01 H'000000000000
20 001-2 001-1-40-02 H'000000000000
20 001-3 001-1-40-03 H'000000000000
20 001-4 001-1-40-04 H'000000000000
20 001-5 001-1-40-05 H'000000000000
20 001-6 001-1-40-06 H'000000000000
20 001-7 001-1-40-07 H'000000000000
20 001-8 001-1-40-08 H'000000000000
20 001-9 001-1-40-09 H'000000000000
20 001-10 001-1-40-10 H'000000000000
20 001-11 001-1-40-11 H'000000000000
20 001-12 001-1-40-12 H'000000000000
20 001-13 001-1-40-13 H'000000000000
20 001-14 001-1-40-14 H'000000000000
20 001-15 001-1-40-15 H'000000000000
20 001-17 001-1-40-17 H'000000000000
20 001-18 001-1-40-18 H'000000000000
20 001-19 001-1-40-19 H'000000000000
20 001-20 001-1-40-20 H'000000000000
20 001-21 001-1-40-21 H'000000000000
20 001-22 001-1-40-22 H'000000000000
20 001-23 001-1-40-23 H'000000000000
20 001-24 001-1-40-24 H'000000000000
20 001-25 001-1-40-25 H'000000000000
20 001-26 001-1-40-26 H'000000000000
20 001-27 001-1-40-27 H'000000000000
20 001-28 001-1-40-28 H'000000000000
20 001-29 001-1-40-29 H'000000000000
20 001-30 001-1-40-30 H'000000000000
20 001-31 001-1-40-31 H'000000000000

END

Step 4. RODDI Route External Destination Data Initiate

Route and Access Code for the trunk Information- Note PRI uses Route 20

<_RODDP:DEST=ALL;
EXTERNAL DESTINATION ROUTE DATA

DEST DRN ROU CHO CUST ADC TRC SRT NUMACK PRE

2 20 100500000000025000 0 1 0
30 1 100500000000025000 0 3 0
31 2 100500000000025000 0 3 0
32 3 100500000000025000 0 3 0
33 4 100500000000025000 0 3 0
34 5 100500000000025000 0 3 0
35 6 000500000000025000 0 3 0
36 7 000500000000025000 0 3 0
37 8 000500000000025000 0 3 0
39 21 100500000000025000 0 3 0
40 11 100500000000025000 0 3 0

END


Note: The Ericsson MD-110 PBX user interface is very cryptic. All parameters and options are mapped to position-dependent numeric fields within the various commands listed below. You must have the correct revision of the Ericsson MD-110 PBX Administration manual to be able to decipher each field position to determine its meaning. Therefore, it is advised not to make changes to an MD-110 PBX unless you know exactly what you are doing. A single number out of place in a command string can cause unusual behavior on the PBX.


Configuration Menus and Commands

Configuring the Cisco Call Manager

Figure 2 6608 Gateway Configuration

Figure 3 

6608 Gateway Configuration, cont.

Missing Art

Figure 4 

6608 Gateway Configuration - Product Specific Configuration

Figure 5 Route Pattern Configuration

Figure 6 Route Pattern Configuration, Cont.

Test Configuration

As shown in Figure 7 below, an Ericsson MD-110 PBX was connected via an ISDN E1 PRI link to a Cisco 6608-E1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-E1 and the PBX.

Figure 7 Test Configuration

Layer 1 (Physical Layer)

The Ericsson MD-110 uses a command line interface which allows you to change many switch features with a single command. The PBX documentation must be consulted to make changes. Physical layer parameters (along with many other features) are controlled by using RODAI command.

Layers 2 & 3 (Q.921 and Q.931)

Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.

Layer 2 Q.921 packets were monitored to ensure that each PBX/6608-E1 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.

Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/trade-in packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.

Telephone calls were made end-to-end in both directions through the Cisco 6608-E1 Gateway. A check was made to ensure that there was an audio path in both directions for each call.

User/Network Settings

The Cisco 6608-E1 Gateway with ISDN protocol type setting of PRI-EURO supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.

The Ericsson MD-110, supports both "USER" (peer-slave) and "NETWORK" (peer-master) protocol sides by using RODAI command.

Test Results

PBX1 configured as ETSI (emulate Network) and Cisco 6608-E1 Gateway configured as PRI EURO (emulate User).

Ericsson MD-110 Switch-type/ Protocol side setting
Cisco 6608-E1 ISDN protocol-type/Protocol side setting

ETSI/Network

PRI EURO/User


Basic Calls: (Enbloc Sending)

Calls Made
Call Comp?
"Calling Number" Passed to Final Destination?
"Calling Name" Passed to Final Destination?
"Called Number" Passed to Orig. Side?
"Called Name" Passed to Orig. Side?
Notes

Phone A to Phone C

Yes

Yes

No

No1

No

2

Phone C to Phone A

Yes

Yes

No

Yes

No

 

1 CallManager is not sending "Connected Number" information in the connect message back to PBX.

2 Calling Name delivery and presentation features are not supported by the Ericsson ISDN PRI Link.


Call Transfers: (Supervised Local Transfers)

Calls Made
Call Comp?
Orig. "Calling Number" displayed on Final Dest. phone?
Orig. "Calling Name" displayed on Final Dest. phone?
"Called Number" display on Orig. phone updated after transfer?
"Called Name" display on Orig. phone updated after transfer?
Notes

Phone C to Phone A Xfr to Phone B

Yes

Yes

No

No

No

 

Phone A to Phone C Xfr to Phone D

Yes

Yes

No

No

No

 

Call Conferencing (Local)

Calls Made
Call Comp?
"Calling Number" passed to remaining conferee when the conferencing phone drops out?
"Calling Name" passed to remaining conferee when the conferencing phone drops out?
"Connected Number" updated on Orig. Caller phone display when a conferee drops out?
"Connected Name" updated on Orig. Caller phone display when a conferee drops out?
Notes

Phone C to Phone A,

Phone A conf Phone B

Yes

(A Drops out)

Yes

(A Drops out)

No

(A Drops out)

No

(A Drops out)

No

 

Phone C to Phone A,

Phone C conf Phone D

Yes

(C Drops out)

No

(C Drops out)

No

(D Drops out)

No

(D Drops out)

No

 

Phone A to Phone C,

Phone C conf Phone D

Yes

(C Drops out)

No

(C Drops out)

No

(C Drops out)

No

(C Drops out)

No

 

Phone A to Phone C,

Phone A conf Phone B

Yes

(A Drops out)

No

(A Drops out)

No

(B Drops out)

No

(B Drops out)

No

 

Call Forward (Local)

Calls Made
Call Comp?
Original "Calling Number" passed to Final Dest.?
Original "Calling Name" passed to Final Dest.?
Forwarding "Called Number" passed to Final Dest.?
Forwarding "Called Name" passed to Final Dest.?
Final dest. "Connected Number" updated at orig. side?
Final dest. "Connected Name" updated at orig. side?
Notes

Phone C to Phone A fwd to Phone B

Yes

Yes

No

Yes

No

No

No

 

Phone A to Phone C fwd to Phone D

Yes

Yes

No

No

No

No

No

 

Appendix

Figure 8 CallManager Software Release:

Ericsson MD-110 Software Version


<_CADAP;
CALENDAR DATA

IDENTITY=DANDS-EURO-TEST
VERSION=ASB50104-R6-SES-R9-BC90D/CNI80

14:49:24
THU 16 AUG 2001

Catalyst 6000 Switch Configuration


Console> sh version
WS-C6006 Software, Version NmpSW: 5.5(6a)
Copyright (c) 1995-2001 by Cisco Systems
NMP S/W compiled on Feb 23 2001, 10:23:18

System Bootstrap Version: 5.3(1)

Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172

Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0
Fw : 5.3(1)
Fw1: 5.4(2)
Sw : 5.5(6a)
Sw1: 5.5(6a)
WS-F6K-PFC SAD05020221 Hw : 1.1
3 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4
Fw : 5.4(2)
Sw : 5.5(6a)
WS-F6K-VPWR Hw : 1.0
4 24 WS-X6624-FXS SAD050203M8 Hw : 3.0
Fw : 5.4(2)
Sw : 5.5(6a)
HP : A00203010007; DSP : A003C031 (3.3.30)
5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010013; DSP1: D005C031 (3.3.30)
HP2: D00403010013; DSP2: D005C031 (3.3.30)
HP3: D00403010013; DSP3: D005C031 (3.3.30)
HP4: D00403010013; DSP4: D005C031 (3.3.30)
HP5: D00403010013; DSP5: D005C031 (3.3.30)
HP6: D00403010013; DSP6: D005C031 (3.3.30)
HP7: D00403010013; DSP7: D005C031 (3.3.30)
HP8: D00403010013; DSP8: D005C031 (3.3.30)
6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010013; DSP1: D005C031 (3.3.30)
HP2: D00403010013; DSP2: D005C031 (3.3.30)
HP3: D00403010013; DSP3: D005C031 (3.3.30)
HP4: D00403010013; DSP4: D005C031 (3.3.30)
HP5: D00403010013; DSP5: D005C031 (3.3.30)
HP6: D00403010013; DSP6: D005C031 (3.3.30)
HP7: D00403010013; DSP7: D005C031 (3.3.30)
HP8: D00403010013; DSP8: D005C031 (3.3.30)

DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 65408K 37541K 27867K 16384K 11546K 4838K 512K 198K 314K

Uptime is 27 days, 4 hours, 16 minutes
Console>
______________________________________________________________________________

Console> sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
4 4 24 FXS WS-X6624-FXS no ok
5 5 8 T1 WS-X6608-T1 no ok
6 6 8 E1 WS-X6608-E1 no ok

Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD05010NBK
3 SAD04420N7B
4 SAD050203M8
5 SAD04400EM0
6 SAD04380DW1

Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)
00-04-c0-f8-42-00 to 00-04-c0-f8-42-01
00-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff
3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)
4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)
5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)
6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)

Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.1
3 Inline Power Module WS-F6K-VPWR 1.0
Console>
______________________________________________________________________________

Console> sh port 6
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
6/1 connected 1 full 2.048 E1
6/2 notconnect 1 full 2.048 E1
6/3 notconnect 1 full 2.048 E1
6/4 notconnect 1 full 2.048 E1
6/5 notconnect 1 full 2.048 E1
6/6 notconnect 1 full 2.048 E1
6/7 notconnect 1 full 2.048 E1
6/8 notconnect 1 full 2.048 E1

Port DHCP MAC-Address IP-Address Subnet-Mask
-------- ------- ----------------- --------------- ---------------
6/1 enable 00-01-c9-d8-63-3e 10.1.1.104 255.255.255.0
6/2 enable 00-01-c9-d8-63-3f 10.1.1.118 255.255.255.0
6/3 enable 00-01-c9-d8-63-40 10.1.1.123 255.255.255.0
6/4 enable 00-01-c9-d8-63-41 10.1.1.117 255.255.255.0
6/5 enable 00-01-c9-d8-63-42 10.1.1.120 255.255.255.0
6/6 enable 00-01-c9-d8-63-43 10.1.1.121 255.255.255.0
6/7 enable 00-01-c9-d8-63-44 10.1.1.122 255.255.255.0
6/8 enable 00-01-c9-d8-63-45 10.1.1.124 255.255.255.0

Port Call-Manager(s) DHCP-Server TFTP-Server Gateway
-------- ----------------- --------------- --------------- ---------------
6/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7

Port DNS-Server(s) Domain
-------- ----------------- -------------------------------------------------
6/1 - -
6/2 - -
6/3 - -
6/4 - -
6/5 - -
6/6 - -
6/7 - -
6/8 - -

Port CallManagerState DSP-Type
-------- ---------------- --------
6/1 registered C549
6/2 registered C549
6/3 registered C549
6/4 registered C549
6/5 registered C549
6/6 registered C549
6/7 registered C549
6/8 registered C549

Port NoiseRegen NonLinearProcessing
----- ---------- -------------------
6/1 enabled enabled
6/2 enabled enabled
6/3 enabled enabled
6/4 enabled enabled
6/5 enabled enabled
6/6 enabled enabled
6/7 enabled enabled
6/8 enabled enabled
Console>

hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Sep 6 12:07:38 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.