Table of Contents
Index
- 4-6
- 1 4-13
- 100BaseT 1-3
- 10BaseT 1-3
- 10BaseT port 1-7
- 3DES 1-5
- 56/64-kbps WAN interface card LEDs 4-6
- 802.1D Spanning Tree 1-4
- AC power
- specifications A-3
- AC power factor correction 1-5, 1-10
- adapter pinouts, terminal
- RJ-45-to-DB-25 B-6
- RJ-45-to-DB-9 B-6
- airflow, Catalyst 4224 switch 1-10
- Asynchronous/Synchronous WAN Interface Card LED 4-11
- attach bracket to eight-port FXS module 4-18
- audience xi
- autoboot, configuring for C-3
- autonegotiation 1-3
- blank faceplates, important functions 3-12
- boot command C-5
- Break key, entering ROM Monitor mode C-2
- cable connectors
- RJ-21 Category 5 4-17
- cable guide installation
- Catalyst 4224 switch 3-11
- cables
- serial adapter 4-9, 4-11
- serial transition 4-9, 4-11
- cabling
- 10/100 ports B-4
- pinouts B-4
- calling party control (CPC) 4-14
- Card 4-8, 4-15, 4-22
- Catalyst 1-6
- Catalyst 4224
- repacking D-1
- slot description 1-7
- CDP 1-4
- CGMP 1-4
- chassis
- Catalyst 4224 A-2
- checklist, site planning 2-3
- Cisco Discovery Protocol
- See CDP
- Cisco Group Management Protocol
- See CGMP
- CLI 1-4
- command-line interface
- See CLI
- commands
- boot C-5
- configuration register C-15
- context C-8
- cookie C-10
- debugging C-8
- dir device C-6
- frame C-9
- fxs_high_density C-12
- meminfo C-6
- priv C-7
- reset C-7
- ROM Monitor C-4
- ROM monitor diagnostics C-1
- stack C-8
- sysret C-10
- version C-7
- common problems and solutions 5-2
- common switch problems 5-1
- components
- switch 1-5
- configuration register
- changing settings C-15
- configuration register command C-14
- Configuring for autoboot C-3
- confreg command
- commands
- confreg C-14
- connecting
- eight-port FXS voice interface card 4-16
- one- and two-port serial card 4-11
- one-port 56/64-kbps DSU/CSU cards 4-5
- one-port multiflex trunk interface card 4-25
- one-port T1/FT1 DSU/CSU cards 4-7
- two-port asynchronous/synchronous serial card 4-9
- two-port FXO interface card 4-20
- two-port FXS voice interface card 4-14
- two-port ISDN BRI cards 4-23
- two-port T1/E1 multiflex trunk interface card 4-27
- connecting power to the switch 3-10
- connectivity problems, solving 5-1
- console connector pinouts B-1
- console port
- adapter pinouts
- RJ-45-to-DB-25 terminal B-6
- RJ-45-to-DB-9 terminal B-6
- cable B-5
- connecting to B-5 to B-6
- console serial port
- connecting 3-10
- description 1-6
- context command C-8
- conventions used xii
- cookie command C-10
- crossover cable
- connectivity problems 5-3
- pinout B-4
- d 4-26
- DC-input power supplies
- connecting system ground 3-9
- debugging commands C-8
- dimensions, chassis A-2
- dimensions of the Catalyst 4224 A-3
- dir device command C-6
- DMS-100 and 5ESS switches 4-21
- document
- conventions xii
- organization xi
- documentation
- related xvi
- drop-and-insert
- function for VWIC/VICs 1-7
- interface cards 1-21
- DSU/CSU, integrated in VWICs 1-19
- DSU/CSU, integrated in WICs 1-13
- E1 multiflex trunk interface card 1-19, 1-20
- echo cancellation (EC) 1-8
- Eight 1-17
- eight-port FXS TM analog interface card
- description 1-17
- eight-port FXS voice interface card
- connecting 4-16
- eight-port RJ21 FXS module connector pinouts B-3
- eight-port RJ21 FXS module link LED 4-20
- encryption
- 3DES 1-5
- IKE SA 1-5
- Environmental Monitoring Feature 1-11
- equipment types to connect the A/S card 4-9
- Ethernet
- speeds
- 100BaseT 1-3
- Ethernet interfaces 1-3
- Ethernet management port
- connecting 3-10
- Ethernet speeds
- 10BaseT 1-3
- excessive frame check sequence (FCS)
- connectivity problem 5-2
- fan assembly 1-9
- fractional T1/E1 networks, and VWICs 1-19
- frame command C-9
- frequency, specifications
- Catalyst 4224 A-2
- front panel LEDs 1-8
- FXO voice interface card LED 4-22
- fxs_high_density_cookie command C-12
- FXS voice interface card LED 4-16
- grounding 3-9
- guidelines, rack-mounting the switch 3-3
- HDA status LED 1-9
- heat dissipation
- determining 2-3
- specifications 2-2
- IEEE 802.1D Spanning Tree 1-4
- IKE SA 1-5
- inline power
- details 1-12
- troubleshooting 5-4
- installing the switch 3-2
- checking accessory kit contents 3-2
- connecting a terminal to the console and Ethernet management ports 3-10
- connecting a terminal to the console serial and Ethernet management ports 3-10
- Installing voice and WAN interface cards 4-2
- Interface 4-17
- IOS CLI, upgrading the ROM Monitor from C-18
- ISDN BRI voice interface card LEDs 4-24
- LEDs
- description (table) 1-8
- front panel 1-8
- power supply 3-10
- two-port T1/E1 multiflex trunk interface card 4-28
- MAC addresses 1-3
- management
- port pinouts B-2
- ports 1-6
- software 1-4
- MDIX connectors
- See media-dependent interface crossed-over connectors
- Media Access Control addresses
- See MAC addresses
- media-dependent interface crossed-over connectors 3-10
- meminfo command C-6
- microprocessor A-2
- modem
- asynchronous 4-9, 4-12
- synchronous 4-9, 4-12
- modules
- heat dissipation 2-3
- power requirements 2-3
- nserting 4-4
- One 1-13
- one- and two-port serial card
- connecting 4-11
- description 1-15
- one-port 56/64-kbps DSU/CSU Card
- description 1-13
- one-port 56/64-kbps DSU/CSU card
- connecting 4-5
- one-port multiflex trunk interface card
- connecting 4-25
- description 1-19
- LEDs 4-27
- one-port T1/FT1 DSU/CSU
- connecting 4-7
- operating altitude A-3
- operating humidity A-3
- operating temperature A-3
- performance problems, solving 5-1
- Pinout convention for the Telco RJ-21 4-20
- pinouts
- adapters B-5 to B-7
- cable, straight-through and crossover B-4
- console connector B-1
- console port B-5 to B-7
- eight-port RJ21 FXS module connector B-3
- management port B-2
- RJ-45-to-DB-25 terminal adapter B-7
- RJ-45-to-DB-9 PC adapter B-6
- RJ-45-to-DB-9 terminal adapter B-6
- rollover cable B-5 to B-7
- ports
- 10BaseT 1-7
- console serial 1-6
- management 1-6
- POST fails or system overheating
- connectivity problem 5-3
- power
- consumption A-3
- specifications A-3
- power, site
- determining power requirements 2-3
- heat dissipation 2-3
- power requirements 2-2
- power supplies
- description 1-10
- supported 1-5
- priv command C-7
- problems and solutions, common 5-2
- procedures
- connecting system ground 3-9
- connecting to the console serial port 3-10
- connecting to the Ethernet management port 3-10
- rack-mounting 3-2
- protocols
- 802.1D Spanning Tree 1-4
- CDP 1-4
- CGMP 1-4
- SNMP 1-4
- TFTP 1-4
- VTP (Virtual Terminal Protocol) 1-4
- PS and RPS LEDs 1-9
- rack-mounting 3-2
- rack-mount kit
- checklist 3-3
- guidelines 3-3
- recovering boot and system images C-16
- Redundant Power System 300 1-10
- related documentation xvi
- Remote Monitoring
- See RMON
- removing the switch from the rack 3-7
- repacking the Catalyst 4224 D-1
- requirements, power supply A-3
- reset command C-7
- Ring on Seize (ROS) 4-14
- RJ-21, pinout convention 4-20
- RJ21 connector specifications 4-16
- RJ-45 802.3-compliant port 1-7
- RMON 1-4
- rollover cable B-5, B-6
- ROMMON, upgrading the ROM Monitor from C-18
- ROM Monitor
- commands C-4
- syntax conventions C-4
- ROM monitor
- diagnostics C-8
- mode, entering C-1
- serial WAN interface card LED 4-13
- setting jumpers
- on two-port FXO card 4-20
- on two-port FXS card 4-14
- show system command to display the power supply 3-10
- Simple Network Management Protocol
- See SNMP
- site planning
- checklist 2-3
- heat dissipation 2-2
- site requirements 2-2
- slots on the Catalyst 4224 switch
- description 1-7
- Smart Serial
- connectors, serial cards 1-15
- ports for the A/S card 4-9
- SNMP 1-4
- software management 1-4
- specifications for the Catalyst 4224 A-3
- stack command C-8
- storage humidity A-3
- straight-through cable pinouts B-4
- switch
- Catalyst 4224 switch, repacking D-1
- components 1-5
- connecting power 3-10
- features 1-1
- verifying installation 3-11
- switch installation, verifying 3-11
- syntax conventions, ROM Monitor C-4
- sysret command C-10
- system ground, connecting 3-9
- system ground the switch, required tools 3-8
- T1/FT1 WAN interface card LEDs 4-8
- T1 multiflex trunk interface card 1-19, 1-20
- terminals
- connecting to the console serial port 3-10
- connecting to the Ethernet management port 3-10
- time-division multiplexing (TDM) ports 1-19
- tools required to install cards 4-1
- tools required to system ground the switch 3-8
- troubleshooting 5-1 to 5-4
- Two 4-24
- two-port asynchronous/synchronous serial card
- connecting 4-9
- description 1-14
- two-port FXO analog interface card
- description 1-18
- two-port FXO card
- setting jumpers 4-20
- two-port FXO interface card
- connecting 4-20
- two-port FXS analog interface card
- description 1-17
- two-port FXS card
- setting jumpers 4-14
- two-port FXS voice interface card
- connecting 4-14
- two-port ISDN BRI/ST card
- description 1-18
- two-port ISDN BRI cards
- connecting 4-23
- two-port multiflex trunk interface cards
- description 1-20
- two-port T1/E1 multiflex trunk interface card
- connecting 4-27
- LEDs 4-28
- Upgrading the ROM Monitor
- from IOS CLI C-18
- from ROMMON C-18
- version command C-7
- VIC 1-17, 1-18, 1-19
- VIC-2FXO-EU 4-16
- virtual LANs
- See VLANs
- Virtual Terminal Protocol
- See VTP (Virtual Terminal Protocol)
- VLANs 1-3
- VLAN Trunk Protocol
- See VTP (VLAN Trunk Protocol)
- voice and WAN interface cards (VWICs)l 1-19
- voice and WAN interface cards, installing 4-2
- VTP (Virtual Terminal Protocol) 1-4
- VTP (VLAN Trunk Protocol) 1-3
- VWIC 1-20, 1-21, 1-22
- VWICs (voice and WAN interface cards) 1-19
- WAN interface cards (WICs) 1-12
- warnings convention xiv
- weight
- chassis A-2
- weight of the Catalyst 4224 A-3
- WIC 1-13, 1-14, 1-15, 1-16
Posted: Wed Jul 24 03:18:28 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.