This section provides the technical specifications for the Catalyst 4224 Access Gateway Switch.
This section includes the following topics:
Table A-1 lists the Catalyst 4224 specifications.
Item | Specification | |
---|---|---|
Environmental |
| |
| 32°F (0°C) to 104°F (40°C) | |
| -13 to 158°F (-25 to 70°C) | |
| 5-90% noncondensing | |
| Up to 6500 ft (2000m) | |
Switching Components | ||
MPC8260 with 200-MHz 603e core | ||
| 35,000 pps @ 64-byte Layer 3, 3.3-Mpps Layer 2 switch | |
| 32 MB |
|
| 64 MB |
|
| 2 (first and second slot support VIC or WIC cards) | |
| 1 (third slot is VIC only) |
|
| 1 (up to 115.2 kbps) |
|
| 1 |
|
| 24 10BASE-T/100BASE-TX auto-sensing full-duplex ports | |
| 8 (RJ-21 connector) |
|
| Yes |
|
| 1024 |
|
| Included onboard |
|
| Yes |
|
Physical Characteristics | ||
3.42 x 17.17 x 14.3 in. | ||
16.5 lb (7.6 kg) | ||
AC Power | ||
| 240W -12V/-48V AC-DC supply | |
| 12V@ 8A, -48V@ 3A |
|
| 100 to 240VAC | |
50 to 60Hz | ||
| 4A max @ 100VAC; 2A max @ 240VAC | |
Airflow | Right side in, left side out |
Table A-2 lists the technical specifications for the Cisco RPS 300 (model PWR300-AC-RPS-N1).
Item | Specification | |
Environmental Ranges | ||
| Operating temperature | 32 to 113°F (0 to 45°C) |
Storage temperature | -13 to 158°F (-25 to 70°C) | |
Operating humidity | 10 to 85% (noncondensing) | |
Storage humidity | 5 to 95% (noncondensing) | |
Operating altitude | Up to 10,000 ft (3,000 m) | |
Storage altitude | Up to 15,000 ft (4,570 m) | |
Power Requirements | ||
| 85 to 264 VAC | |
| ||
Physical Dimensions | ||
| 10.5 lb (4.7 kg) | |
1.75 x 17.5 x 12 in. |