cc/td/doc/product/lan/cat2950/12112cea
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Index
Numerics
A
C
D
E
F
G
H
I
J
L
M
N
O
P
Q
R
S
T
U
V
W

Index


Numerics

10/100/1000 ports

cable lengths   2-7, 3-10

connecting to   2-38  to 2-40, 3-42  to 3-44

connectors and cables   B-3

described   1-6  to 1-7

10/100 ports

cable lengths   2-7, 3-10

connecting to   2-38  to 2-40, 3-42  to 3-44

connectors and cables   B-1  to B-2

described   1-6

100BASE-FX ports

cable lengths   2-7, 3-10

connecting to   2-41  to 2-42, 3-45  to 3-47

connectors and cables   B-4

described   1-7

power levels, fiber-optic   A-2

100BASE-LX ports

cable lengths   2-7, 3-10

connecting to   2-43  to 2-44, 3-47  to 3-49

connectors and cables   B-5

described   1-8

power levels, fiber-optic   A-3

A

AC power

connecting to   2-19  to 2-21

adapter pinouts, terminal

RJ-45-to-DB-25   B-12

RJ-45-to-DB-9   B-11

addresses, assigning IP   2-45, 3-50

airflow

required clearance   2-8, 3-10

alarm relay connections

power and relay connector   1-8

alarms and relays

LEDs   1-16

altitude   A-1

autonegotiation

10/100/1000 ports   1-7

10/100 ports   1-6

C

cables

10/100/1000 ports   1-6  to 1-7

10/100 ports   1-6

100BASE-FX ports   1-7

100BASE-LX ports   1-8

crossover

connecting to   B-2, B-3

four twisted-pair pinout, 10/100 ports   B-9

four twisted-pair pinout, 1000BASE-T ports   B-10

two twisted-pair pinout   B-8

LC   B-6

LC patch cables   B-6

multimode

100BASE-FX ports   1-7

problems, solving   4-3

rollover   B-12

single-mode

100BASE-LX ports   1-8

straight-through

connecting to   B-2, B-3

four twisted-pair pinout, 10/100 ports   B-8

four twisted-pair pinout, 1000BASE-T ports   B-9

two twisted-pair pinout   B-7

twisted-pair

10/100/1000 ports   1-6  to 1-7

10/100 ports   1-6

See also connectors and cables

Catalyst 2955C-12 switch

illustrated   1-4

LEDs

illustrated   1-12

Catalyst 2955S-12 switch

illustrated   1-4

LEDs

illustrated   1-12

Catalyst 2955 switch

warning labels   1-5

Catalyst 2955T-12 switch

illustrated   1-3

LEDs

illustrated   1-11

cautions, defined   xvi

chassis warnings

against stacking   2-3, 3-5

rack-mounting, servicing   2-32, 3-36

servicing   C-4

Cisco IE2100   1-18

Cisco IE2100 Series Configuration Registrar

See Cisco IE2100

Cisco Intelligent Engine 2100

See Cisco IE2100

CiscoView   1-18

Class 1 laser product warning   2-4, 3-6, B-5

class 1 laser product warning   C-14

Class 1 LED product warning   2-4, 2-41, 3-6, 3-45, B-4

class 1 LED product warning   C-16

clearance   2-7, 3-10

CLI   1-18

Cluster Builder application   1-17

Cluster Management Suite

See CMS

Cluster Manager application   1-17

Cluster View application   1-17

CMS

Cluster Builder   1-17

Cluster Management   1-17

Cluster View   1-17

described   1-17

Device Manager   1-18

command-line interface

See CLI

configuration examples, network   1-1

configuring ports   2-45, 3-50

connecting

to 10/100/1000 ports   2-38  to 2-40, 3-42  to 3-44

to 10/100 ports   2-38  to 2-40, 3-42  to 3-44

to 100BASE-FX ports   2-41  to 2-42, 3-45  to 3-47

to 100BASE-LX ports   2-43  to 2-44, 3-47  to 3-49

to console port   2-9  to 2-10, 3-12  to 3-13

to DC power   2-14  to 2-23, 3-18  to 3-26

to PC   2-9  to 2-10, 3-12  to 3-13

to terminal   2-9  to 2-10, 3-12  to 3-13

to the AC/DC converter   2-19  to 2-21

connecting to

external alarm devices   2-25  to 2-28, 3-28  to 3-31

connectivity problems, solving   4-4

connectors and cables

10/100/1000 ports   B-3

10/100 ports   B-1  to B-2

100BASE-FX ports   B-4

100BASE-LX ports   B-5

console port   B-7

See also cables

console port

adapter pinouts

RJ-45-to-DB-25 terminal   B-12

cable, rollover   B-12

connecting to   2-9  to 2-10, 3-12  to 3-13, B-10  to B-12

default characteristics   2-10, 3-13

described   1-9

RJ-45-to-DB-9 adapter cable pinouts   B-11

conventions, document   xvi  to xviii

crossover cable

connecting to

10/100/1000 ports   2-39, 3-43

10/100 ports   2-39, 3-43

connectivity problems   4-4

pinout

four twisted-pair, 10/100 ports   B-9

four twisted-pair, 1000BASE-T ports   B-10

two twisted-pair   B-8

D

DC power

connecting to   2-14  to 2-23, 3-18  to 3-26

warnings   2-14, 3-18

DC power disconnection warning   2-14

default characteristics of the console port   2-10, 3-13

Device Manager   1-18

dimensions   A-2

documentation

ordering   xx

related publications   xix

URLs, Cisco   xx

document conventions   xvi  to xviii

E

electrical noise, avoiding   2-8, 3-11

electromagnetic interface (EMI)   A-3

EMC

agency approvals   A-3

regulatory statements   2-5  to 2-7, 3-7  to 3-9

ensure that the switch is grounded warning   2-3, 3-6

environmental ranges   A-1

ESD

requirements   2-38, 3-42

European Zone 2 certification

regulatory statements   3-9

examples, network configuration   1-1

exposed DC power wire warning   2-16, 2-20, 3-20

F

features   1-1  to 1-2

feedback to Cisco Systems, web   xx

ferrite

attaching   2-21, 3-24

fiber-port specifications   A-2, A-3

front panel

10/100/1000 ports   1-6  to 1-7

10/100 ports   1-6

100BASE-FX ports   1-7

100BASE-LX ports   1-8

clearance   2-7, 3-10

console port   1-9

described   1-3

illustrated   1-3  to 1-4

LEDs   1-10  to 1-16

power and relay connector   1-8

functional ground lug warning   2-3, 2-12, 3-6, 3-15

G

ground connection warning   2-3, 2-12, 3-6, 3-15

grounded equipment warning   C-29

grounding procedures   2-12  to 2-14, 3-15  to 3-18

H

hazardous location warnings

connecting and disconnecting cables   3-5

console cable   1-10, 3-5, 3-12, 3-14, 3-26

disconnecting equipment   3-2

power and relay connector   1-8, 3-3

relay wires   1-16, 3-3, 3-28

safe operating voltage range   3-3

suitable enclosure   3-4

hot surface warning label

illustrated   1-5

HP OpenView   1-18

humidity   A-1

I

industrial environment warning   2-2, 3-3

installation

attaching the ferrite   2-21, 3-24

attach the power and relay connector   2-22, 3-25

grounding procedures   2-12  to 2-14, 3-15  to 3-18

guidelines   2-7, 3-10

mounting on a DIN rail   2-29  to 2-31, 3-32  to 3-35

package contents   2-8  to 2-9, 3-11  to 3-12

POST   2-23  to 2-25, 3-26  to 3-28

power on   2-23, 3-26

pre-installation information and guidelines   2-2  to 2-7, 3-2  to 3-10

rack-mount   2-32  to 2-33, 3-36  to 3-37

required clearance   2-8, 3-10

verifying switch operation   2-9  to 2-25, 3-12  to 3-28

warning   C-2

wiring the relays   2-25  to 2-28, 3-28  to 3-31

invisible laser radiation warning   2-4, 3-7, B-5

IOS command-line interface

See CLI

IP address procedures   2-45, 3-50

J

jewelry removal warning   2-4, 3-6, C-11

L

laser beam exposure warning   2-5, 3-7

laser radiation warning   2-4, 3-7, C-20

laser safety warning label

illustrated   1-5

laser viewing warning   2-4, 3-7, C-18

LC

patch cables   B-6

LED radiation warning   2-4, 2-41, 3-7, 3-45, B-4

LEDs

alarm and relay   1-16

alarms and relay status   1-16

front panel   1-10  to 1-16

port   1-13

port status   1-13

power status   1-12

uplink ports   1-14  to 1-15

uplink port status   1-14  to 1-15

lightning activity warning   2-4, 3-6, C-1

M

main disconnecting device warning   2-3, C-7

management options   1-17  to 1-18

mounting

DIN rail   2-29  to 2-31, 3-32  to 3-35

rack   2-32  to 2-33, 3-36  to 3-37

MT-RJ

connector   B-4

N

network configuration examples   1-1

noise, electrical   2-8, 3-11

notes, defined   xvi

O

obtaining documentation   xx

overtemperature warning   2-3, 3-5, C-27

P

package contents   2-8  to 2-9, 3-11  to 3-12

patch cables, LC   2-9, 3-12

patch cables, MT-RJ   2-9, 2-41, 2-43, 3-11, 3-45, 3-47

PC, connecting to switch   2-9  to 2-10, 3-12  to 3-13, B-10  to B-11

performance problems, solving   4-3

physical dimensions   A-2

pinouts

10/100/1000 ports   B-4

10/100 ports   B-2

adapters

DB-25   B-12

console port

DB-25 adapter   B-12

RJ-45-to-DB-9 adapter cable   B-11

crossover cables

four twisted-pair, 10/100 ports   B-9

four twisted-pair, 1000BASE-T ports   B-10

two twisted-pair   B-8

RJ-45-to-DB-25 terminal adapter   B-12

RJ-45-to-DB-9 adapter cable   B-11

RJ-45-to-DB-9 PC adapter cable   B-11

straight-through cables

four twisted-pair, 10/100 ports   B-8

four twisted-pair, 1000BASE-T ports   B-9

two twisted-pair   B-7

port

10/100/1000BASE-T

LEDs   1-14

100BASE-FX

LEDs   1-15

100BASE-LX

LEDs   1-15

LEDs   1-13  to 1-15

ports

See 10/100 ports, 10/100/1000 ports, 100BASE-FX ports, 100BASE-LX ports, and console ports

POST

description   2-23, 3-26

problems, solving   4-4

results   2-23, 3-26

power

connecting to

AC   2-19  to 2-21

DC   2-14  to 2-23, 3-18  to 3-26

power and relay connector   1-8

LEDs   1-12

requirements   A-1

power and relay connector

connecting to the switch   2-22, 3-25

described   1-8

illustrated   1-9

power connection

power and relay connector   1-8

power on   2-11, 3-14

power on the switch   2-23, 3-26

procedures

connecting to AC power   2-19  to 2-21

connecting to DC power   2-14  to 2-23, 3-18  to 3-26

installation   2-32  to 2-33, 3-36  to 3-37

IP address   2-45, 3-50

power on   2-11  to 2-18, 3-14  to 3-23

product disposal warning   2-4, 3-6, C-30

publications, related   xix

Q

qualified personnel warning   C-32

R

rack-mounting

procedures   2-32  to 2-33, 3-36  to 3-37

warning   2-32, 3-36

rear panel

clearance   2-7, 3-10

regulatory statements, EMC   2-5  to 2-7, 3-7  to 3-9

regulatory statements, European Zone 2 certification   3-9

related publications   xix

relays

connecting to

power and relay connector   1-8

described   1-8

wiring   2-25  to 2-28, 3-28  to 3-31

removing the switch from a DIN rail or a rack   2-35  to 2-37, 3-39  to 3-41

restricted area warning   C-33

rollover cable   B-12

S

safety agency approvals   A-3

safety warnings   2-2  to 2-5, 3-2  to 3-7, C-1  to C-39

SELV-IEC 60950 DC power supply warning   C-9

service personnel warning   2-2, 3-2

SNMP network management platforms   1-18

software switch management   1-17  to 1-18

specifications   A-1  to A-4

stacking the chassis warning   2-3, 3-5, C-5  to C-6

straight-through cable

connecting to

10/100/1000 ports   2-39, 3-43

10/100 ports   2-39, 3-43

connectivity problems   4-4

pinout

four twisted-pair, 10/100 ports   B-8

four twisted-pair, 1000BASE-T ports   B-9

two twisted-pair   B-7

SunNet Manager   1-18

supply wires warning   2-3, 2-12, 3-4, 3-15

switch, power-on   2-11  to 2-23, 3-14  to 3-26

T

technical assistance   xxii  to xxiii

technical specifications   A-1  to A-4

Telnet, and accessing the CLI   1-18

temperature

operating   A-1

warning   2-3, 3-5, C-27

terminal, connecting to a switch   2-9  to 2-10, 3-12  to 3-13, B-11  to B-12

terminal-emulation software   2-9, 3-12

translated warnings   C-1  to C-39

troubleshooting   4-1

diagnosing problems   4-2  to 4-4

understanding POST results   4-2

U

uplink ports

LEDs   1-14  to 1-15

URLs, Cisco   xx

V

verifying package contents   2-8  to 2-9, 3-11  to 3-12

verifying switch operation   2-9  to 2-25, 3-12  to 3-28

W

warning labels

hot surface   1-5

illustrated   1-5

laser safety   1-5

warnings

Class 1 laser product   2-4, 3-6, B-5

class 1 laser product   C-14

Class 1 LED product   2-4, 2-41, 3-6, 3-45, B-4

class 1 LED product   C-16

DC power   2-14, 3-18

defined   xvii  to xviii

ensure that the switch is grounded   2-3, 3-6

functional ground lug   2-3, 2-12, 3-6, 3-15

ground connection   2-3, 3-6

grounded equipment   C-29

hazardous locations

connecting and disconnecting cables   3-5

console cable   1-10, 3-5, 3-12, 3-14, 3-26

disconnecting equipment   3-2

power and relay connector   1-8, 3-3

relay wires   1-16, 3-3, 3-28

safe operating voltage range   3-3

suitable enclosure   3-4

industrial environment   2-2, 3-3

installation   2-2  to 2-5, 3-2  to 3-7, C-2

invisible laser radiation   2-4, 3-7, B-5

jewelry removal   2-4, 3-6, C-11

laser beam exposure   2-5, 3-7

laser radiation   2-4, 3-7, C-20

laser viewing   2-4, 3-7, C-18

LED radiation   2-4, 2-41, 3-7, 3-45, B-4

lightning activity   2-4, 3-6, C-1

main disconnecting device   2-3, C-7

overtemperature   2-3, 3-5, C-27

product disposal   2-4, 3-6, C-30

qualified personnel   C-32

restricted area   C-33

SELV-IEC 60950 DC power supply   C-9

service personnel   2-2, 3-2

servicing   C-4

stacking the chassis   2-3, 3-5, C-5  to C-6

supply wires   2-3, 2-12, 3-4, 3-15

temperature   2-3

translated   C-1  to C-39

wiring the relays   2-25  to 2-28, 3-28  to 3-31


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Apr 25 20:11:28 PDT 2003
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.