FastPAD Events

FastPAD Events


Table A-1: FastPADmp Events and Assigned Traps
Event Description Trap Number Trap Summary Node Severity

00_00: A Restart occured after a system crash; a Clear is sent; the info indicates CPU status.

90000

System Restart after crash (from <Node X.25 Address>, info=<Info>)

major

00_01: Correct reset of FastPADmpr has occurred; info indicates: Module number, backup type.

90001

FastPADmpr reset (from <Node X.25 Address>, info=<Info>)

normal

00_02: A failure occurred on FastPADmpr Module 0; info indicates: Module number, backup type.

90002

FastPADmpr Module 0 failure (from <Node X.25 Address>, info=<Info>)

minor

00_03: A failure occurred on FastPADmpr Module 1. info indicates: Module number, backup type.

90003

FastPADmpr Module 1 failure (from <Node X.25 Address>, info=<Info>)

minor

00_04: A failure occurred on FastPADmpr Module 2. info indicates: Module number, backup type.

90004

FastPADmpr Module 2 failure (from <Node X.25 Address>, info=<Info>)

minor

00_05: A correct reset of FastPADmp has occurred.

90005

FastPADmp reset (from <Node X.25 Address>)

normal

00_06: FastPADmpr Module 0 is in standby mode, backed up, awaiting unit reset. info indicates: Module number, backup type.

90006

FastPADmpr Module 0 standby (from <Node X.25 Address>, info=<Info>)

normal

00_07: FastPADmpr Module 1 is in standby mode, backed up, awaiting unit reset. info indicates: Module number, backup type.

90007

FastPADmpr Module 1 standby (from <Node X.25 Address>, info=<Info>)

normal

00_08: FastPADmpr Module 2 is in standby mode, backed up, awaiting unit reset. info indicates: Module number, backup type.

90008

FastPADmpr Module 2 standby (from <Node X.25 Address>, info=<Info>)

normal

00_09: Initiation of the module auto-loading operation has occurred; info indicates: loading module, loaded module, cause: 01 = configurations are different, 02 = different software versions, 03 = module running BOOT program.

90009

Start of auto-loading (from <Node X.25 Address>, info=<Info>)

normal

00_0A: Completion of the module auto-loading operation has occurred; info indicates: status after loading: 80 = OK, 82 = write or sequence error, 83 = time-out.

90010

End of auto-loading (from <Node X.25 Address>, info=<Info>)

normal

00_0B: A Startcard problem was detected and successfully corrected.

90011

Startcard problem (from <Node X.25 Address>)

warning

00_0C: The system is restarted due to operator initiated action.

90012

Operator initiated system startup (from <Node X.25 Address>)

normal

00_0D: The system is restarted due to a hardware reset or initial startup.

90013

Hardware reset system startup (from <Node X.25 Address>)

normal

00_0E: FastPADmpr Module 0 has gone offline; info indicates: module number, event generator, backup type.

90014

FastPADmpr Module 0 offline (from <Node X.25 Address>, info=<Info>)

warning

00_0F: FastPADmpr Module 0 has come online; info indicates: module number, event generator, backup type.

90015

FastPADmpr Module 0 online (from <Node X.25 Address>, info=<Info>)

normal

00_10: FastPADmpr Module 1 has gone offline; info indicates: module number, event generator, backup type.

90016

FastPADmpr Module 1 offline (from <Node X.25 Address>, info=<Info>)

warning

00_11: FastPADmpr Module 1 has come online; info indicates: module number, event generator, backup type.

90017

FastPADmpr Module 1 online (from <Node X.25 Address>, info=<Info>)

normal

00_12: FastPADmpr Module 2 has gone offline; info indicates: module number, event generator, backup type.

90018

FastPADmpr Module 2 offline (from <Node X.25 Address>, info=<Info>)

warning

00_13: FastPADmpr Module 2 has come online; info indicates: module number, event generator, backup type.

90019

FastPADmpr Module 2 online (from <Node X.25 Address>, info=<Info>)

normal

01_13: An erroneous command was received; the circuit is Cleared.

90275

Erroneous command received (from <Node X.25 Address>)

warning

01_14: A data packet was received before an expected command acknowledgement was received; the circuit is Cleared.

90276

Data received before command ACK (from <Node X.25 Address>)

warning

01_16: The billing ticket threshold has been exceeded; the circuit is Cleared.

90278

Billing ticket threshold exceeded (from <Node X.25 Address>)

warning

01_17: The oldest detailed billing ticket has been lost; the circuit is Cleared; info indicates: module that lost ticket, number of tickets lost.

90279

Oldest detailed billing ticket lost (from <Node X.25 Address>, info=<Info>)

warning

01_20: The node has accepted the download operation.

90288

Download operation accepted (from <Node X.25 Address>)

normal

01_21: The node has refused the download operation due to no RAM storage being available.

90289

Download refused: no RAM (from <Node X.25 Address>)

minor

01_22: The node has refused the download operation due to no Flash PROM storage being available.

90290

Download refused: no Flash PROM (from <Node X.25 Address>)

minor

01_23: The node has completed the download operation with no errors.

90291

Download complete: no error (from <Node X.25 Address>)

normal

01_24: The node has completed the download operation with a result of checksum error.

90292

Download failed: checksum error (from <Node X.25 Address>)

minor

01_25: The node has completed the download operation with a result of incomplete load.

90293

Download failed: incomplete load (from <Node X.25 Address>)

minor

01_26: The node has completed the downloading operation with a result of bad version.

90294

Download failed: bad version (from <Node X.25 Address>)

minor

01_27: The node has accepted the uploading operation.

90295

Upload operation accepted (from <Node X.25 Address>)

normal

01_28: The node has refused the upload operation due to no RAM storage being available.

90296

Upload refused: no RAM (from <Node X.25 Address>)

minor

01_29: The node has refused the upload operation due to no Flash PROM storage being available.

90297

Upload refused: no Flash PROM (from <Node X.25 Address>)

minor

01_2A: The node has completed the upload operation with no errors.

90298

Upload complete: no error (from <Node X.25 Address>)

normal

01_2B: The node has completed the upload operation with a result of checksum error.

90299

Upload failed: checksum error (from <Node X.25 Address>)

minor

01_2C: The node has completed the upload operation with a result of incomplete load.

90300

Upload failed: incomplete load (from <Node X.25 Address>)

minor

01_2D: The node has completed the upload operation with a result of bad version.

90301

Upload failed: bad version (from <Node X.25 Address>)

minor

01_2E: The node has completed the uploading operation and copied RAM to FPROM.

90302

Upload complete: copied RAM to FPROM (from <Node X.25 Address>)

normal

01_30: A Call has been setup to a Management Access Point; info indicates: maximum MAPs, MAPs open.

90304

Call setup with MAP (from <Node X.25 Address>, info=<Info>)

normal

01_31: No Logical Channel is available for completing setup of a Management Access Point session.

90305

LC unavailable for MAP session (from <Node X.25 Address>)

warning

01_32: The maximum number of concurrent Management Access Point sessions has been reached; the MAP Call is Cleared; info indicates: maximum MAPs.

90306

Maximum MAP sessions (from <Node X.25 Address>, info=<Info>)

warning

01_33: A Management Access Point session has been opened.

90307

MAP session opened (from <Node X.25 Address>)

normal

01_34: A Management Access Point session open attempt failed; the MAP menu is displayed.

90308

MAP session open failed (from <Node X.25 Address>)

warning

01_35: A Management Access Point session was Cleared from a remote node; the MAP menu is displayed.

90309

MAP session Cleared by remote (from <Node X.25 Address>)

normal

01_36: A Management Access Point session is closed; the MAP menu is displayed.

90310

MAP session closed (from <Node X.25 Address>)

normal

01_37: A Management Access Point Call was Cleared.

90311

MAP Call Cleared (from <Node X.25 Address>)

normal

01_C0: The Sample number in Extended Statistics is exceeded.

90448

Sample number exceeded (from <Node X.25 Address>)

warning

01_C1: The Sampling counter in Extended Statistics is full.

90449

Sampling counter full (from <Node X.25 Address>)

warning

01_C2: The Hour counter in Extended Statistics is full.

90450

Hour counter full (from <Node X.25 Address>)

warning

01_C3: The Threshold-Exceeded counter in Extended Statistics is full.

90451

Threshold-Exceeded counter full (from <Node X.25 Address>)

warning

01_C4: The Day counter in Extended Statistics is full.

90452

Day counter full (from <Node X.25 Address>)

warning

01_C5: A Configuration error in Extended Statistics has occurred.

90453

Configuration error (from <Node X.25 Address>)

warning

01_D0: An invalid value was detected on a configuration parameter for DLM; the Management Access Point is Cleared.

90464

Configuration parameter invalid on DLM (from <Node X.25 Address>, line <Port Number>)

warning

01_D1: The minimum threshold was not exceeded on DLM; the throughput is lower than the maximum threshold; info indicates: rate of last period (4 bytes), secondary line number, line status, maximum data rate (4 bytes), line cost.

90465

Minimum threshold not exceeded on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

01_D2: The maximum threshold has been exceeded on DLM; info indicates: rate of last period (4 bytes), secondary line number, line status, maximum data rate (4 bytes), line cost.

90466

Maximum threshold exceeded on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

01_E3: A Call was received with an incorrect password; the Call is Cleared.

90483

Call received with incorrect password (from <Node X.25 Address>)

warning

01_E5: A Call was received with an incorrect parameter; the Call is Cleared.

90485

Call received with incorrect parameter (from <Node X.25 Address>)

warning

01_E9: An incorrect Statistics function command was entered; the circuit is Reset.

90489

Incorrect Statistics function command (from <Node X.25 Address>)

warning

02_00: A Call was rejected due to the maximum number of concurrent SVCs being reached.

90512

Maximum VCs reached (from <Node X.25 Address>, line <Port Number>)

minor

02_02: A Call was rejected due to a Call Request packet being too long.

90514

Call Request too long (from <Node X.25 Address>, line <Port Number>)

warning

02_03: A Call was rejected due to a Call Request packet being too short.

90515

Call Request too short (from <Node X.25 Address>, line <Port Number>)

warning

02_05: A Call was rejected due to the calling address in a received Call Request being too short.

90517

Calling address too short (from <Node X.25 Address>, line <Port Number>)

warning

02_08: A Call was rejected due to an incorrect facility or utility field in a received Call Request.

90520

Incorrect facility in Call (from <Node X.25 Address>, line <Port Number>)

warning

02_09: A Call was rejected due to a duplicate facility or utility field in a received Call Request.

90521

Duplicate facility in Call (from <Node X.25 Address>, line <Port Number>)

warning

02_0B: A Call was rejected due to an unauthorized facility or utility field in a received Call Request.

90523

Unauthorized facility in Call (from <Node X.25 Address>, line <Port Number>)

warning

02_0C: A Call was rejected due to a routing being impossible in a received Call Request; the called DNIC is unknown or the associated routing has not been configured; info indicates: Called DNIC.

90524

Routing impossible in Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_0F: A Call was cleared due to receipt of a Call Confirmation that is too long.

90527

Call Confirmation too long (from <Node X.25 Address>, line <Port Number>)

warning

02_10: A Call was cleared due to receipt of a Call Confirmation that is too short.

90528

Call Confirmation too short (from <Node X.25 Address>, line <Port Number>)

warning

02_12: A Call was cleared due to receipt of a Call Confirmation with an error in a facility or utility field.

90530

Call Confirmation error (from <Node X.25 Address>, line <Port Number>)

warning

02_14: A Call was cleared due to receipt of a Call Confirmation with a duplicate facility or utility field.

90532

Duplicate facility in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_15: A Call was cleared due to receipt of a Call Confirmation with an unauthorized facility or utility field.

90533

Unauthorized facility in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_17: A Call was cleared due to receipt of a Call Confirmation with an invalid throughput class value.

90535

Invalid throughput class in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_18: A Call was cleared due to receipt of a Call Confirmation with an invalid window size value.

90536

Invalid window size in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_20: A Call was cleared due to receipt of a Call Request with a non-numeric address.

90544

Non-numeric address in Call Request (from <Node X.25 Address>, line <Port Number>)

warning

02_22: A Call was cleared due to receipt of a Call Request with too many ZO's.

90546

Too many ZO's in Call Request (from <Node X.25 Address>, line <Port Number>)

warning

02_23: A Call was cleared due to receipt of a Call Confirmation with a non-numeric address.

90547

Non-numeric address in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_26: A Call was cleared due to receipt of a Call Confirmation with an invalid packet size.

90550

Invalid packet size in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_27: A Call was cleared due to receipt of a Call Confirmation with an incomplete called address.

90551

Incomplete called address in Call Confirmation (from <Node X.25 Address>, line <Port Number>)

warning

02_28: A Call was cleared due to an incorrect PDN line table entry.

90552

Incorrect PDN line table (from <Node X.25 Address>, line <Port Number>)

warning

02_29: A Call was cleared due to a decompacted address not being found in tables.

90553

Decompacted address not found (from <Node X.25 Address>, line <Port Number>)

warning

02_2A: A Call was cleared due to a compacted address not being found in tables.

90554

Compacted address not found (from <Node X.25 Address>, line <Port Number>)

warning

02_2B: A Call was cleared due to decompacting not being possible.

90555

Decompacting not possible (from <Node X.25 Address>, line <Port Number>)

warning

02_2C: A Call was cleared due to compacting not being possible.

90556

Compacting not possible (from <Node X.25 Address>, line <Port Number>)

warning

02_2E: A Call was cleared due to a requested internal subscriber being offline; info indicates: Called DNIC.

90558

Internal subscriber offline (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_30: A Call was cleared due to a requested output line being down; info indicates: Called DNIC.

90560

Output line is down (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

02_31: A Call was cleared due to receipt of a Clear with a non-numeric address.

90561

Non-numeric address in Clear (from <Node X.25 Address>, line <Port Number>)

warning

02_32: A Call was cleared due to an error in received Clear address, facility or utility lengths.

90562

Inconsistent lengths in Clear (from <Node X.25 Address>, line <Port Number>)

warning

02_33: A Call was cleared due to receipt of a Clear with length values that do not conform to the X.25 standards.

90563

Non-standard length in Clear (from <Node X.25 Address>, line <Port Number>)

warning

02_34: A Call was cleared due to receipt of a Clear with an incorrect facility or utility field.

90564

Incorrect facility in Clear (from <Node X.25 Address>, line <Port Number>)

warning

02_35: A Call was cleared due to receipt of a Clear with a duplicate facility or utility field.

90565

Duplicate facility in Clear (from <Node X.25 Address>, line <Port Number>)

warning

02_36: A Call was cleared due to receipt of a Call Return that is not authorized.

90566

Unuathorized Call Return (from <Node X.25 Address>, line <Port Number>)

warning

02_3C: A Call Return was received with inconsistencies in type between the incoming and outgoing lines; the Call is Cleared.

90572

Inconsistent Call Return type (from <Node X.25 Address>, line <Port Number>)

warning

02_3D: A Call Request was received with an unmanaged utility on an X.75 line; the Call is Cleared; info indicates: utility code received.

90573

Unmanaged utility in Call Request on X.75 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_3E: A Call Confirmation was received with an unmanaged utility on an X.75 line; the Call is Cleared; info indicates: utility code received.

90574

Unmanaged utility in Call Confirmation on X.75 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_3F: A Clear was received with an unmanaged utility on an X.75 line; the Call is Cleared; info indicates: utility code received.

90575

Unmanaged utility in Clear on X.75 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_40: A Call Request was received on an X.75 line without a required "Identification of Call" utility; the Call is Cleared.

90576

Missing "Call-ID" utility in Call Request on X.75 (from <Node X.25 Address>, line <Port Number>)

warning

02_41: A Closed User Group facility was present in a Call Request to be sent on an X.75 line; the Call is Cleared; info indicates: CUG number.

90577

CUG present in Call Request on X.75 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

02_50: A routable line came online; the line is placed in service.

90592

Routable line online (from <Node X.25 Address>, line <Port Number>)

normal

02_51: A routable line went offline; the line is taken out of service.

90593

Routable line offline (from <Node X.25 Address>, line <Port Number>)

minor

03_00: An unknown address was received in an X.25 frame; the frame is ignored; info indicates: byte1 of frame.

90768

Unknown address in X.25 frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_01: An X.25 Frame of incorrect length was received; the frame was ignored if it was an I-frame or an FRMR was sent if it was a U or S-frame; info indicates: length of frame, byte1 of frame, byte2 of frame.

90769

Incorrect length in X.25 frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_02: An X.25 Frame with inverted address was received.

90770

Inverted address in X.25 frame (from <Node X.25 Address>, line <Port Number>)

warning

03_03: An X.25 frame with an unknown command was received; an FRMR was sent with W=1; info indicates: byte2 of frame.

90771

Unknown command in X.25 frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_04: An X.25 frame with an unknown response was received; an FRMR was sent with W=1; info indicates: byte2 of frame.

90772

Unknown response in X.25 frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_05: An X.25 frame was received without the F-bit set after sending a frame with the P-bit set; the frame is ignored.

90773

X.25 frame without F-bit after P-bit (from <Node X.25 Address>, line <Port Number>)

warning

03_06: An X.25 frame was received with the F-bit set after sending a frame without the P-bit set; the frame is ignored.

90774

X.25 frame with F-bit after no P-bit (from <Node X.25 Address>, line <Port Number>)

warning

03_07: An unexpected X.25 frame was received while in DISCONNECTED mode; info indicates: byte1 of frame, byte2 of frame.

90775

Unexpected X.25 frame in DISCONNECTED mode (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_08: X.25 Level 1 (physical) link is down and Level 2 retries are being attempted; line = 0-35 for physical link, line = 36-41 for inter-unit link, line = 50-55 for inter-module link.

90776

X.25 Link down (from <Node X.25 Address>, line <Port Number>)

major

03_09: X.25 Level 1 (physical) link is up and Level 2 retries are being attempted; line = 0-35 for physical link, line = 36-41 for inter-unit link, line = 50-55 for inter-module link.

90777

X.25 Link up (from <Node X.25 Address>, line <Port Number>)

normal

03_0A: An unexpected X.25 frame was received while in CONNECTED mode; the frame is ignored; info indicates: byte1 of frame, byte2 of frame.

90778

Unexpected X.25 frame in CONNECTED mode (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_0B: An invalid X.25 frame was received while in the FRMR state; an FRMR was sent; info indicates: byte2 of frame.

90779

Invalid X.25 frame in FRMR state (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_0C: An X.25 frame with an incorrect N(R) was received; an FRMR was sent with Z=1; info indicates: byte2 of frame.

90780

X.25 frame with incorrect N(R) received (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_0E: An X.25 frame was received out of sequence or with a duplicate N(R); an FRMR was sent; info indicates: byte2 of frame.

90782

X.25 frame out of sequence or duplicate N(R) (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_0F: An X.25 frame was received outside the sequence window; an FRMR was sent; info indicates: byte2 of frame.

90783

X.25 frame received outside sequence window (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_10: An X.25 FRMR frame was received; a SABM was sent.

90784

X.25 FRMR received (from <Node X.25 Address>, line <Port Number>)

normal

03_12: An invalid expiration of timeout T1 occurred.

90786

Invalid expiration of T1 timeout on X.25 (from <Node X.25 Address>, line <Port Number>)

warning

03_13: An X.25 packet was received with an invalid GFI; a Clear, Restart or Reset was sent, depending on the state of the Packet Level; info indicates: byte3 of frame. byte5 of frame.

90787

X.25 packet with invalid GFI (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_14: An X.25 Restart or Restart Confirmation was received on a channel other than Logical Channel #0; info indicates: byte3 of frame. byte4 of frame.

90788

X.25 Restart or Restart Confirmation not on LC#0 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_15: An X.25 Restart Confirmation was received without a Restart having been sent; Restart is sent; info indicates: packet level state: 1 = packet level inactive due to frame level down, 2 = packet level in service, 3 = reply confirmation to be sent, 4 = awaiting restart confirmation, 5 = restart to be sent.

90789

X.25 Restart Confirmation without Restart sent (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_16: An unexpected X.25 packet was received during Restart; info indicates: byte5 of frame.

90790

Unexpected packet during X.25 Restart (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_17: An X.25 Restart was re-sent after a timeout; now waiting a Confirmation.

90791

Re-sending X.25 Restart on timeout (from <Node X.25 Address>, line <Port Number>)

warning

03_18: An X.25 packet was received on an un-configured Logical Channel; a Clear is sent; info indicates: byte3 of frame, byte4 of frame, byte5 of frame.

90792

X.25 packet on un-configured LC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_19: An unexpected X.25 packet was received on a free Logical Channel; info indicates: byte5 of frame.

90793

Unexpected X.25 packet on free LC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_1A: An X.25 Clear Confirmation was received on a free Logical Channel.

90794

X.25 Clear Confirmation received on free LC (from <Node X.25 Address>, line <Port Number>)

warning

03_1B: An X.25 Clear was received on a free Logical Channel.

90795

X.25 Clear received on free LC (from <Node X.25 Address>, line <Port Number>)

warning

03_1C: An X.25 Clear Confirmation was received without having sent a Clear; info indicates: Logical Channel state: 1 = LC allocated due to receipt of this Clear Confirmation, 2 = LC ready (in data transfer mode).

90796

X.25 Clear Confirmation received without Clear sent (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_1D: An unexpected X.25 packet was received after a Clear was received; info indicates: byte5 of frame.

90797

Unexpected X.25 packet received after Clear (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_1E: An unexpected X.25 packet was received on an established SVC; a Clear was sent; info indicates: byte5 of frame.

90798

Unexpected X.25 packet on established SVC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_1F: An unexpected X.25 Call was received after a Call Request had been sent; a Clear was sent; info indicates: byte5 of frame.

90799

Unexpected X.25 Call received after Call sent (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_20: An X.25 Call collision occurred; a Clear was sent.

90800

X.25 Call collision (from <Node X.25 Address>, line <Port Number>)

warning

03_21: An unexpected X.25 packet was received after a Call was received; a Clear was sent; info indicates: byte5 of frame.

90801

Unexpected X.25 packet received after Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_22: A packet was received of an unknown type on an X.25 line; info indicates: byte5 of frame.

90802

Unknown packet type received on X.25 (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_23: An X.25 Clear was sent after a time-out; now waiting for a Clear Confirmation.

90803

Awaiting Clear Confirmation after timeout on X.25 (from <Node X.25 Address>, line <Port Number>)

warning

03_24: An X.25 Call Request was sent after a time-out; now waiting for a Call Confirmation.

90804

Awaiting Call Confirmation after timeout on X.25 (from <Node X.25 Address>, line <Port Number>)

warning

03_25: An X.25 Reset Confirmation was received without having sent a Reset; info indicates: Logical Channel state: 1 = LC allocated due to receipt of this Clear Confirmation, 2 = LC ready (in data transfer mode).

90805

X.25 Reset Confirmation received without Reset sent (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_26: An unexpected X.25 packet was received after a Reset was received; info indicates: byte5 of frame.

90806

Unexpected packet received after X.25 Reset (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_27: Two consecutive X.25 Interrupt packets were received; a Reset was sent.

90807

Consecutive X.25 Interrupt packets received (from <Node X.25 Address>, line <Port Number>)

warning

03_28: An X.25 Interrupt Confirmation was received without an Interrupt packet having been sent.

90808

X.25 Interrupt Confirmation received without Interrupt (from <Node X.25 Address>, line <Port Number>)

warning

03_29: An X.25 Data packet was received outside the sequence window; a Reset was sent.

90809

X.25 Data packet received outside sequence window (from <Node X.25 Address>, line <Port Number>)

warning

03_2A: An X.25 Data packet was received out of sequence; a Reset was sent.

90810

X.25 Data packet received out of sequence (from <Node X.25 Address>, line <Port Number>)

warning

03_2B: An X.25 Data Packet with an incorrect N(S) was received.

90811

X.25 Packet with incorrect N(S) received (from <Node X.25 Address>, line <Port Number>)

warning

03_2C: An X.25 REJ packet was received.

90812

X.25 REJ packet received (from <Node X.25 Address>, line <Port Number>)

normal

03_2D: An X.25 Reset was sent, now waiting for a response;

90813

Awaiting response to Reset on X.25 (from <Node X.25 Address>, line <Port Number>)

normal

03_2E: An X.25 RNR packet was received; Data Packet transmission is blocked until an RR is received.

90814

X.25 RNR packet received, send blocked (from <Node X.25 Address>, line <Port Number>)

normal

03_2F: An invalid X.25 packet was received via a PVC; the packet is ignored; info indicates: byte3 of frame, byte4 of frame.

90815

Invalid X.25 packet received via PVC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_30: An X.25 frame was repeated N times without acknowledgement; info indicates: frame level state.

90816

X.25 frame retried N times without ACK (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_31: An unexpected X.25 frame was received with the Frame Level down; info indicates: frame level state, byte1 of frame, byte2 of frame, byte3 of frame.

90817

Unexpected X.25 frame with Frame Level down (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_32: An unexpected X.25 frame was received while the Frame Level was in the DISCONNECTING state; info indicates: frame level state, byte1 of frame, byte2 of frame, byte3 of frame.

90818

Unexpected X.25 frame with Frame Level disconnecting (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_33: An unexpected X.25 frame was received while the Frame Level was in the CONNECTING state; info indicates: frame level state, byte1 of frame, byte2 of frame.

90819

Unexpected X.25 frame with Frame Level connecting (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_35: An X.25 Diagnostic packet was received; a Clear was sent; info indicates: byte6 of frame, byte7 of frame, byte8 of frame, byte9 of frame.

90821

Reception of an X.25 Diagnostic packet (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

03_36: An X.25 Reset packet was received with reason unknown; info indicates: Logical Channel number, Reset diagnostic.

90822

X.25 Reset received with reason unknown (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

03_37: An X.25 Reset packet was sent with reason unknown; info indicates: Logical Channel number, Reset diagnostic.

90823

X.25 Reset sent with reason unknown (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

04_00: The Logical Link Level is down; all VC traffic is blocked; line = 0-35 for physical link, line = 36-41 for inter-unit link, line = 50-55 for inter-module link.

91024

Link Level down (from <Node X.25 Address>, line <Port Number>)

major

04_01: The Logical Link Level is up; all VC traffic is enabled; line = 0-35 for physical link, line = 36-41 for inter-unit link, line = 50-55 for inter-module link.

91025

Link Level up (from <Node X.25 Address>, line <Port Number>)

normal

05_01: The I/O controller has lost one or more frames.

91281

Loss of frames in I/O controller (from <Node X.25 Address>, line <Port Number>)

minor

05_02: Line signals changed; Modem: circuit 117 (StandBy) off, terminal: circuit 141 (LL) off.

91282

Line signals 117/141 off (from <Node X.25 Address>, line <Port Number>)

normal

05_03: Line signals changed; Modem: circuit 117 (StandBy) on, terminal: circuit 141 (LL) on.

91283

Line signals 117/141 on (LocalLoopback) (from <Node X.25 Address>, line <Port Number>)

normal

05_81: The I/O controller lost one or more receive frames; info indicates: number of frames lost.

91409

Loss of receive frames in I/O controller (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

05_82: Line signals changed; Modem: circuit 109 (DCD) on, terminal: circuit 105 (RTS) on.

91410

Line signals 109/105 on (from <Node X.25 Address>, line <Port Number>)

normal

05_83: Line signals changed; Modem: circuit 109 (DCD) off, terminal: circuit 105 (RTS) off.

91411

Line signals 109/105 off (from <Node X.25 Address>, line <Port Number>)

normal

05_85: Line signals changed; Modem: circuit 106 (CTS) off, terminal: circuit 108 (DTR) off.

91413

Line signals 106/108 off (from <Node X.25 Address>, line <Port Number>)

normal

05_86: Line signals changed; Modem: circuit 107 (DSR) off, terminal: circuit 111 (RateSelect) off.

91414

Line signals 107/111 off (from <Node X.25 Address>, line <Port Number>)

normal

05_87: An ABORT was received on a line.

91415

ABORT received (from <Node X.25 Address>, line <Port Number>)

normal

05_88: A MALFUNCTION was received on a line.

91416

MALFUNCTION received at physical level (from <Node X.25 Address>, line <Port Number>)

minor

05_8C: A frame was received with a CRC error; the frame is ignored.

91420

CRC error on Receive frame (from <Node X.25 Address>, line <Port Number>)

minor

05_90: Line signals changed; Modem: circuit 141 (LL) off, terminal: circuit 125 (RI) off.

91424

Line signals 141/125 off (from <Node X.25 Address>, line <Port Number>)

normal

05_91: Line signals changed; Modem: circuit 141 (LL) on, terminal: circuit 125 (RI) on.

91425

Line signals 141/125 on (from <Node X.25 Address>, line <Port Number>)

normal

05_92: Line signals changed; Modem: circuit 142 (TM) off, terminal: circuit 140 (Test) off.

91426

Line signals 142/140 off (from <Node X.25 Address>, line <Port Number>)

normal

05_93: Line signals changed; Modem: circuit 142 (TM) on, terminal: circuit 140 (Test) on.

91427

Line signals 142/140 on (from <Node X.25 Address>, line <Port Number>)

normal

05_95: Line signals changed; Modem: circuit 106 (CTS) on, terminal: circuit 108 (DTR) on.

91429

Line signals 106/108 on (from <Node X.25 Address>, line <Port Number>)

normal

05_96: Line signals changed; Modem: circuit 107 (DSR) on, terminal: circuit 111 (RateSelect) on.

91430

Line signals 107/111 on (from <Node X.25 Address>, line <Port Number>)

normal

05_BF: An incomplete Byte was received; the line is taken out of service.

91471

Incomplete Byte received (from <Node X.25 Address>, line <Port Number>)

minor

05_FD: Loss of sync flags occurred.

91533

Loss of sync flags (from <Node X.25 Address>, line <Port Number>)

warning

05_FE: Restoral of sync flags occurred.

91534

Restoral of sync flags (from <Node X.25 Address>, line <Port Number>)

normal

06_97: An attempt to activate an LSCP (Low Speed Computer Port) failed; the next LCSP defined for the subscriber will be tried, if all have been tried, the Call fails.

91687

LSCP activation failure on Async (from <Node X.25 Address>, line <Port Number>)

warning

06_98: The terminal is not set to the correct Baud rate or is not set to the correct number of Stopbits; the received character is ignored.

91688

Incorrect baud rate or stop bits on Async (from <Node X.25 Address>, line <Port Number>)

minor

06_99: The Autobaud procedure detected a rate higher than that supported by Autobaud (38.4Kbps); the line has not been Autobauded.

91689

Excess rate detected on Async (from <Node X.25 Address>, line <Port Number>)

minor

06_9A: The terminal dropped circuit 105 (RTS) for more than 200ms indicating disconnection; any Call in progress is cleared, the terminal is taken out of service.

91690

Terminal disconnected after 200ms on Async (from <Node X.25 Address>, line <Port Number>)

warning

06_9C: The terminal raised circuit 105 (RTS); if it is set for a fixed rate, it is activated immediately, otherwise the automatic rate detection sequence is awaited (Autobaud).

91692

Terminal connected on Async (from <Node X.25 Address>, line <Port Number>)

normal

06_9D: The requested Videotex service is not available, eg: error correction protocol or modem reversal); the Call is cleared.

91693

Videotex service not available on Async (from <Node X.25 Address>, line <Port Number>)

warning

06_9E: The automatic data rate detection sequence (Autobaud) detected a valid rate from the attached terminal; the terminal is activated.

91694

Terminal data rate recognized on Async (from <Node X.25 Address>, line <Port Number>)

normal

06_9F: The automatic data rate detection sequence (Autobaud) received an invalid rate from the attached terminal; the Call is terminated if PSTN type, otherwise a valid sequence is awaited.

91695

Terminal data rate not recognized on Async (from <Node X.25 Address>, line <Port Number>)

warning

07_9B: An erroneous command was entered at the terminal; the "ERROR" message is sent to the terminal and Data Mode is re-entered if a Call is active; info indicates: last character received.

91947

Erroneous terminal command (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

08_92: The current Call in progress is dropped; a clear message is sent (if the profile allows it), for an LSCP line, circuit 105 (RTS) is dropped, for a PSTN line, the check time-out is reset.

92194

Call in progress cut off (from <Node X.25 Address>, line <Port Number>)

warning

08_93: A Call setup was attempted from a terminal managed by the FastPADmp; a Call Block is sent and the terminal enters Data Mode when a Call Confirmation is received.

92195

Call attempt via FastPADmp (from <Node X.25 Address>, line <Port Number>)

normal

08_9D: An X.29 message was received; the appropriate response and action are generated.

92205

X.29 message received (from <Node X.25 Address>, line <Port Number>)

normal

08_A0: The Call setup time on a PSTN line took too long.

92208

Phone line: call setup timeout (from <Node X.25 Address>, line <Port Number>)

warning

08_A1: Command entry was attempted before a Call has been setup.

92209

Phone line: command entry without Call (from <Node X.25 Address>, line <Port Number>)

warning

08_A2: Too many command entries were attempted without a Call setup.

92210

Too many commands without Call (from <Node X.25 Address>, line <Port Number>)

warning

08_A3: Minitel turnaround succeeded; data rate set to: 1200bps (receive) / 75bps (transmit).

92211

Minitel turnaround succeeded (from <Node X.25 Address>)

normal

08_A4: Minitel reverse turnaround succeeded; data rate set to: 75bps (receive) / 1200bps (transmit).

92212

Minitel reverse turnaround succeeded (from <Node X.25 Address>)

normal

08_A7: Activation of Error Correction Protocol - Normal Mode (ECPN) succeeded.

92215

Activation of ECPN succeeded (from <Node X.25 Address>)

normal

08_A8: Activation of Error Correction Protocol - Normal Mode (ECPN) failed after 8 attempts.

92216

Activation of ECPN failed (from <Node X.25 Address>)

warning

08_A9: Inactivation of Error Correction Protocol - Normal Mode (ECPN) succeeded.

92217

Inactivation of ECPN succeeded (from <Node X.25 Address>)

normal

08_AA: Inactivation of Error Correction Protocol - Normal Mode (ECPN) failed after 8 attempts.

92218

Inactivation of ECPN failed (from <Node X.25 Address>)

warning

08_AB: An ECPN re-transmission request was received.

92219

Received ECPN re-transmission request (from <Node X.25 Address>)

normal

08_AC: Activation of Error Correction Protocol - Inverse Mode (ECPI) succeeded.

92220

Activation of ECPI succeeded (from <Node X.25 Address>)

normal

08_AD: Inactivation of Error Correction Protocol - Inverse Mode (ECPI) succeeded.

92221

Inactivation of ECPI succeeded (from <Node X.25 Address>)

normal

08_AE: An ECPN re-transmission request was transmitted.

92222

Transmitted ECPN re-transmission request (from <Node X.25 Address>)

normal

09_00: An SDLC Frame with an unknown address was received; the frame is ignored; info indicates: address field.

92304

Unknown address in SDLC Frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_01: An SDLC Frame with an invalid length was received; the frame is ignored; info indicates: frame length, address field, command field.

92305

Invalid length in SDLC Frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_03: An SDLC Frame with an unknown command was received; an FRMR is sent; info indicates: address field, command field.

92307

Unknown command in SDLC Frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_04: An SDLC Frame with an unknown response was received; the frame is ignored; info indicates: address field, command field.

92308

Unknown response in SDLC Frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_0C: An SDLC Frame with an incorrect N(R) was received; a Clear VC is sent to the remote, an FRMR is sent to the FEP; info indicates: address field, command field.

92316

Incorrect N(R) in SDLC Frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_0E: An SDLC Frame out of sequence or with duplicate sequence was received; the frame is ignored; info indicates: address field, command field.

92318

Sequence error or duplicate SDLC frame (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_0F: An SDLC Frame was received outside the sequence window; the frame is ignored; info indicates: address field, command field.

92319

SDLC Frame outside window (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_10: An SDLC FRMR frame was received on the Remote side only; the Transmit and Receive counters are reset, an SNRM is sent, the VC is Cleared; info indicates: address field, command field.

92320

FRMR SDLC Frame Remote side only (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_11: An SDLC Frame encountered N2 retries in the data transfer phase; the frame is re-sent; info indicates: address field, command field.

92321

Data transfer retries exceeded on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_12: An SDLC Frame encountered N2 retries in the test phase; the frame is re-sent; info indicates: address field, command field.

92322

Test phase retries exceeded on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_13: An SDLC Frame encountered N2 retries in the ID phase; frame is re-sent; info indicates: address field, command field.

92323

ID phase retries exceeded on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_14: An SDLC Frame encountered N2 retries in the mode positioning phase; the frame is re-sent; info indicates: address field, command field.

92324

Mode positioning phase retries exceeded on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_15: An SDLC Frame encountered N2 retries in the DISC phase; the frame is re-sent; info indicates: address field, command field.

92325

DISC retries exceeded on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_16: A T1 timeout occured on an SDLC Frame from a T2.1 cluster in the Connection phase; polling continues; info indicates: address field, command field.

92326

Connection T1 timeout on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_17: A T1 timeout occured on an SDLC Frame during SNRM polling; polling continues; info indicates: address field, command field.

92326

SNRM polling T1 timeout on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_31: An SDLC Frame was received on a circuit in the non-established state; the frame is ignored; info indicates: address field, command field.

92353

SDLC Frame error received on VC not established (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_32: An SDLC UA Frame was received on a remote circuit in the non-established state; the X.25 level is Cleared, a DISC is sent at Frame level; info indicates: address field, command field.

92354

SDLC UA Frame error received on remote circuit (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_33: An SDLC UA Frame was received on a local circuit in the non-established state; X.25 level is Cleared, a DISC is sent at Frame level; info indicates: address field, command field.

92355

SDLC UA Frame error received on local circuit (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_35: An SDLC XID Frame was received on a circuit; the X.25 level is Cleared, DISC is sent at Frame level; info indicates: address field, command field.

92357

XID Frame error received on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_80: An SDLC VC encountered circuit 108 (DTR) drop; the VC is Cleared; info indicates: address field, command field.

92432

Line signal 108 (DTR) drop caused Clear on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_81: A Call request was transmitted on an SDLC line; info indicates: address field, logical channel.

92433

Call request sent on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_82: A Clear was transmitted on an SDLC line; info indicates: address field, logical channel.

92434

Clear sent on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_83: A Call was received on an SDLC line; a Call Confirmation is sent; info indicates: address field, logical channel.

92435

Call received on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_84: An invalid Call was received on an SDLC line while in FRONT mode.

92436

Invalid Call in SDLC FRONT mode (from <Node X.25 Address>, line <Port Number>)

warning

09_85: An SDLC line encountered circuit 108 (DTR) drop; SNRM polling is started.

92437

Line signal 108 (DTR) drop caused SNRM on SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_86: A BackUp Call packet was sent on an SDLC line.

92438

BackUp Call sent on SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_87: A Clear Confirmation was received on an SDLC line; info indicates: address field, logical channel.

92439

Clear Confirmation on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_88: A Call Confirmation was received on an SDLC line; info indicates: address field, logical channel.

92440

Call Confirmation on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_89: Call retries on a Backup SDLC line were exhausted; the Call is Cleared.

92441

Backup Call retries exhausted on SDLC (from <Node X.25 Address>, line <Port Number>)

warning

09_8A: A Clear was received on an SDLC line; a Call Request is sent; info indicates: address field, logical channel.

92442

Clear on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_8B: Call retries on an SDLC line were exhausted; the Call is Cleared; info indicates: address field, logical channel.

92443

Call retries exhausted on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_8C: A Call Request with an error was received on an SLDC line; code C2 was not found in Byte 0 of the Call Request data field; the Call is Cleared; info indicates: logical channel.

92444

Protocol Error in Call on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_8D: An unexpected PSH-LLC packet was received on an SDLC line; the VC is Cleared; info indicates: address field, logical channel.

92445

Unexpected PSH-LLC on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_8E: An unexpected frame was received on an SDLC line; the VC is Cleared; info indicates: address field, logical channel.

92446

Unexpected Frame on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_8F: A sequence error was detected in a PSH-LLC packet received on an SLDC line; the VC is Cleared; info indicates: address field, logical channel.

92447

Sequence error in PSH-LLC on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_90: The state of a VC switched to Data Transfer on an SDLC line; info indicates: address field, logical channel.

92448

Switched to Data Transfer on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

09_91: An unexpected packet was received while in Data Transfer state (PSH-LLC) on an SDLC line; the VC is Cleared or the packet is ignored, see C12RxxP38 setting; info indicates: address field, logical channel.

92449

Unexpected packet in Data Transfer on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_92: A "Disable in outgoing transmission state" was received on an SDLC line.

92450

Disable Send state in SLDC (from <Node X.25 Address>, line <Port Number>)

normal

09_93: A "Disable in current receive state" was received on an SDLC line.

92451

Disable Receive state in SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_94: A "Disable in Blocked state" was received on an SDLC line.

92452

Disable in Blocked state on SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_95: A T1 transmission timeout occurred on an SDLC line; info indicates: address field.

92453

Transmission timeout on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_96: An I-Frame was received during send on an SDLC line; the frame is ignored; info indicates: frame length, address field, command field, byte1 of data.

92454

I-Frame during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_97: An RR frame with P/F=0 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92455

RR with P/F=0 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_98: An RR frame with P/F=1 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92456

RR with P/F=1 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_99: An RNR frame with P/F=0 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92457

RNR with P/F=0 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9A: An RNR frame with P/F=1 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92458

RNR with P/F=1 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9B: An REJ frame with P/F=0 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92459

REJ with P/F=0 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9C: An REJ frame with P/F=1 was received during send on an SDLC line; the frame is ignored; info indicates: address field, command field.

92460

REJ with P/F=1 during send on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9D: A packet with a 2nd PSH byte of unknown command type was received on an SDLC line; the packet is ignored; info indicates: address field, logical channel.

92461

Packet with 2nd PSH on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9E: A "Transmit Report" (TR) message was received while in receive status on an SDLC line; the frame is ignored; info indicates: address field.

92462

Transmit Report message in receive state on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_9F: A "Transmit Report" (TR) message was received while in blocked status on an SDLC line; the frame is ignored; info indicates: address field.

92463

Transmit Report message in blocked state on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_C0: A QUA was received during Data Transfer on an SDLC line; the packet is ignored; info indicates: address field, logical channel.

92496

QUA during Data Transfer on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_C1: An unknown packet was received during Data Transfer state (QLLC) on an SDLC line; a Clear is sent or the packet is ignored, see C12RxxP38 setting; info indicates: address field, logical channel.

92497

Unknown packet in Data Transfer on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_C2: An unknown command packet was received on an SDLC line; the packet is ignored; info indicates: address field, logical channel.

92498

Command packet unknown on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

09_CD: An unexpected QLLC packet was received on an SDLC line; the VC is Cleared; info indicates: address field, logical channel.

92509

Unexpected QLLC packet on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_CE: An unexpected QLLC packet was received on an SDLC line, 2nd encoded event; the VC is Cleared; info indicates: address field, logical channel.

92510

Unexpected QLLC packet-2 on SDLC (from <Node X.25 Address>, line <Port Number>. info=<Info>)

warning

09_CF: The QLLC protocol requested a Clear on an SDLC line; the VC is Cleared; info indicates: address field, logical channel.

92511

QLLC Clear on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

09_D0: A request to establish a VC was received from a remote node; a Call Request is sent.

92512

Remote request for VC on SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_D1: A requested VC was established on an SDLC line.

92513

VC established on SDLC (from <Node X.25 Address>, line <Port Number>)

normal

09_D2: An XID for a Cluster controller was received on an SDLC line; the appropriate QLLC protocol element is sent; info indicates: logical channel.

92514

Cluster XID on SDLC (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0A_00: An ABORT with cause unknown was received on a VIP line.

92560

ABORT received for unknown cause on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_01: An X.25 network RESET was received for an associated VIP line; a RESET is sent and the VIP VC is Cleared.

92561

X.25 RESET from network on VIP (from <Node X.25 Address>, line <Port Number>)

normal

0A_02: An ABORT due to frame too long was received on a VIP line; the frame is ignored, sequence is restarted.

92562

ABORT received for frame too long on VIP (from <Node X.25 Address>, line <Port Number>)

minor

0A_03: An ABORT due to reception time out was received on a VIP line; the frame is ignored, sequence is restarted.

92563

ABORT received for receive time out on VIP (from <Node X.25 Address>, line <Port Number>)

minor

0A_04: An ABORT due to a VRC error was received on a VIP line; the frame is ignored, sequence is restarted.

92564

ABORT received for VRC error on VIP (from <Node X.25 Address>, line <Port Number>)

minor

0A_05: An ABORT due to an LRC error was received on a VIP line; the frame is ignored, sequence is restarted.

92565

ABORT received for LRC error on VIP (from <Node X.25 Address>, line <Port Number>)

minor

0A_06: An Abort due to not being available to X.25 level was received on a VIP line; selectively cleared.

92566

ABORT received for not available to X.25 on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_07: An Abort due to a lost character at the Handler level was received on a VIP line.

92567

ABORT received for lost character on VIP (from <Node X.25 Address>)

warning

0A_08: An Abort was transmitted for an unknown cause on a VIP line.

92568

ABORT transmitted for cause unknown on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_0E: A protocol violation occurred on a VIP line.

92574

Protocol violation on VIP (from <Node X.25 Address>)

warning

0A_0F: An event was prohibited on a VIP line at the physical level.

92575

Event prohibited in VIP physical (from <Node X.25 Address>)

warning

0A_11: A NAK screen was received on a VIP line; immediate re-transmission occurs.

92577

NAK screen on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_12: A BSY screen was received on a VIP line; re-transmission is delayed.

92578

BSY screen on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_13: A PGOF screen was received on a VIP line; re-transmission is delayed.

92579

PGOF screen on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_14: A NAK printer message was received on a VIP line; immediate re-transmission occurs.

92580

NAK printer on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_15: A BSY printer message was received on a VIP line; re-transmission is delayed.

92581

BSY printer on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_16: A NA (Not Accepted) printer message was received on a VIP line; re-transmission is delayed.

92582

NA printer on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0A_17: Re-initialization of VIP equipment occurred.

92583

Re-initialization of VIP equipment (from <Node X.25 Address>, line <Port Number>)

warning

0A_18: Too many NAKs were received on a VIP line; the screen message is discarded.

92584

Too many NAKs on VIP (from <Node X.25 Address>)

warning

0A_19: Too many NAKs or NAs were received from a printer on a VIP line; all printer messages are discarded.

92585

Too many NAKs or NAs from printer on VIP (from <Node X.25 Address>)

warning

0A_1F: A protocol violation at the logical level occurred on a VIP line; the line is Reset.

92591

Protocol violation on VIP (from <Node X.25 Address>)

warning

0A_21: A Connection was issued to an X.25 network (Call) on a VIP line; Call is accepted if station is polled, otherwise Call is refused and Clear is sent.

92593

Connection issued X.25 network on VIP (from <Node X.25 Address>, line <Port Number>)

normal

0A_22: A Disconnection was issued on an X.25 network (Clear) on a VIP line; the VIP connection is Cleared, re-connect on the controller side is attempted.

92594

Disconnection issued X.25 network on VIP (from <Node X.25 Address>, line <Port Number>)

normal

0A_23: A Connection was issued by VIP; a Call packet is sent.

92595

Connection issued VIP controller (from <Node X.25 Address>, line <Port Number>)

normal

0A_24: A Disconnection was issued by VIP on: controller: no response to polling, host: no reception to polling frame.

92596

Disconnection issued VIP controller (from <Node X.25 Address>, line <Port Number>)

normal

0A_25: An unknown address was received on a VIP line.

92597

Unknown VIP address (from <Node X.25 Address>, line <Port Number>)

warning

0A_2F: An event was prohibited in a VIP connection.

92607

Event prohibited in VIP connection (from <Node X.25 Address>)

warning

0A_30: Data flow toward the host is blocked; the I/O block is deleted; all messages are discarded; info indicates: station number.

92608

Flow toward host blocked on VIP (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0A_31: A host response timer expired on a VIP line; the I/O block flow is re-transmitted to the host info indicates: station number.

92609

Response timeout on VIP (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0A_40: A Reset was received for an unknown cause on a VIP line.

92624

Reset for unknown cause on VIP (from <Node X.25 Address>, line <Port Number>)

warning

0B_00: A Call is initiated on a FR, T.VIP or BSC line; awaiting Call Confirmation.

92816

Initiating a Call on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_01: A Call Request was refused due to unknown equipment or node on a FR, T.VIP or BSC line; a Clear is sent.

92817

Call refused, unknown node on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

warning

0B_02: Communication is Cleared on a FR, T.VIP or BSC line; awaiting Clear Confirmation.

92818

Communication cleared on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_03: Partially transmitted messages were aborted on FR, T.VIP or BSC line.

92819

Messages aborted on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

warning

0B_04: A RESET was received on a FR, T.VIP or BSC line; any partial messages are removed from the receive queue, the DLC sub-assembly state is reset.

92820

RESET received on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_05: A RESET was sent on a FR, T.VIP or BSC line; awaiting receipt of a RESET.

92821

RESET sent on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_15: A VC Call is initiated on the controller side on a FR, T.VIP or BSC line; Call packet contains polled VIP address.

92837

VC Call initiated on controller side on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_16: A VC Call was refused on the host side on a FR, T.VIP or BSC line due to: - VIP node not polled by host or - VIP node not configured; the VC is Cleared.

92838

VC Call refused on host side on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

warning

0B_21: A VC Call is intiated on the host side on a FR, T.VIP or BSC line.

92849

VC Call initiated on host side on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

normal

0B_22: A VC Call was refused on the controller side on a FR, T.VIP or BSC line.

92850

VC Call refused on controller side on FR/TVIP/BSC (from <Node X.25 Address>, line <Port Number>)

warning

0C_00: A Station requested a Disconnect on a DLC or BSC line; the VC is Cleared; info indicates: station connection state, see Management Manual Appendix B.

93072

Station Disconnect on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_01: A Station requested a Connect on a DLC or BSC line, when the controller has not been previously polled; the VC is Initiated.

93073

Station Connect on DLC/BSC (from <Node X.25 Address>)

normal

0C_02: The line is out of service on a DLC or BSC line, OR a controller or station is disconnected; info indicates: detailed cause, see Management Manual Appendix B; for: line down: communications to all stations is Cleared, controller disconnect: all stations on this controller are Cleared, station disconnect: this station is Cleared.

93074

Line down on DLC/BSC (from <Node X.25 Address>, info=<Info>)

major

0C_03: Station Connect issued while station is Connecting on a DLC or BSC line; the Station Connect request is ignored.

93075

TPAD collision on DLC/BSC (from <Node X.25 Address>)

warning

0C_04: A Station Connect occurred on a DLC/BSC line, caused by recovery on the line in progress; info indicates: controller and station addresses, see Management Manual Appendix B;

93076

Recovery of Station Connect on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_05: A Disconnect of the controller station on a DLC or BSC line occurred; see Management Manual Appendix B;

93077

Disconnect the controller on DLC/BSC (from <Node X.25 Address>)

normal

0C_06: A Disconnect of a non-controller station on a DLC or BSC line occurred; the Call is refused; see Management Manual Appendix B;

93078

Disconnect non-controller on DLC/BSC (from <Node X.25 Address>)

normal

0C_18: A Disconnect from the network was received on a DLC or BSC line; see Management Manual Appendix B;

93096

Disconnect from network on DLC/BSC (from <Node X.25 Address>)

normal

0C_19: A Connect from the network was received on a DLC or BSC line; see Management Manual Appendix B;

93097

Connect from network on DLC/BSC (from <Node X.25 Address>)

normal

0C_20: Unknown data was received on a DLC or BSC line; the message is rejected; see Management Manual Appendix B;

93104

Unknown data on DLC/BSC (from <Node X.25 Address>)

warning

0C_21: An unknown control character was received on a DLC or BSC line; see Management Manual Appendix B;

93105

Unknown control character on DLC/BSC (from <Node X.25 Address>)

warning

0C_22: An unknown station or unknown CA-DA was detected on a DLC or BSC line; the message is ignored; see Management Manual Appendix B;

93106

Unknown station on DLC/BSC (from <Node X.25 Address>)

warning

0C_23: An unknown controller was detected on a DLC or BSC line; see Management Manual Appendix B;

93107

Unknown controller on DLC/BSC (from <Node X.25 Address>)

warning

0C_24: An unknown CA-DA/BCC parity error (single block) occurred on a DLC or BSC line; EOT is transmitted; see Management Manual Appendix B;

93108

Unknown CA-DA/BCC parity error on DLC/BSC (from <Node X.25 Address>)

warning

0C_25: The wrong controller responded to a poll on a DLC or BSC line; EOT is transmitted; see Management Manual Appendix B.

93109

Wrong controller responded to poll on DLC/BSC (from <Node X.25 Address>)

warning

0C_26: A controller is no longer being polled by the host; all stations on that controller are disconnected; info indicates: address of controller, see Management Manual Appendix B.

93110

Controller no longer polled by host on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_27: A control message was received during transmission on a BSC3270 line; see Management Manual Appendix B.

93111

Control message received during transmission on BSC (from <Node X.25 Address>)

normal

0C_29: The inactivity timeout expired on a DLC or BSC line; the VC is Cleared; info indicates further detail, see Management Manual Appendix B.

93113

Inactivity timeout expired on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_30: The ENQ-SEL counter overflowed on a DLC or BSC line; station is disconnected.

93120

ENQ-SEL counter overflow on DLC/BSC (from <Node X.25 Address>)

warning

0C_31: The TTD-SEL counter overflowed on a DLC or BSC line; the station is disconnected.

93121

TTD-SEL counter overflow on DLC/BSC (from <Node X.25 Address>)

warning

0C_32: The ENQ.Rx counter overflowed on a DLC or BSC line.

93122

ENQ.Rx counter overflow on DLC/BSC (from <Node X.25 Address>)

warning

0C_33: The NAK.Rx counter overflowed on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93123

NAK.Rx counter overflow on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_34: The EOT.Tx counter overflowed on a DLC or BSC line; the station is disconnected.

93124

EOT.Tx counter overflow on DLC/BSC (from <Node X.25 Address>)

warning

0C_35: The ENQ.Tx counter overflowed on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93125

ENQ.Tx counter overflow on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_36: The NAK.Tx counter overflowed on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93126

NAK.Tx counter overflow on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_43: An ENQ collision occurred on a DLC or BSC line; no transport will occur in data transfer mode; see Management Manual Appendix B.

93139

ENQ collision on DLC/BSC (from <Node X.25 Address>)

warning

0C_44: An IT (ENQ) collision occurred on a DLC or BSC line; no transport will occur in data transfer mode; see Management Manual Appendix B.

93140

IT (ENQ) collision on DLC/BSC (from <Node X.25 Address>)

warning

0C_45: An RVI was received on a DLC or BSC line; a "state RVI" message is sent; see Management Manual Appendix B.

93141

RVI message received on DLC/BSC (from <Node X.25 Address>)

normal

0C_46: An ENQ message was received on a DLC or BSC line; transport in data transfer mode is either refused or authorized to continue; see Management Manual Appendix B.

93142

ENQ message received on DLC/BSC (from <Node X.25 Address>)

normal

0C_47: An ENQ message was accepted on a DLC or BSC line; transport in data transfer mode is authorized; info indicates further detail, see Management Manual Appendix B.

93143

ENQ message accepted on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_48: An ENQ message was refused on a DLC or BSC line; transport in data transfer mode is refused; info indicates further detail, see Management Manual Appendix B.

93144

ENQ message refused on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_49: End of data transfer was detected on a DLC or BSC line; an EOT is sent; info indicates further detail, see Management Manual Appendix B.

93145

End of data transfer occurred on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_50: An ENQ packet was received or transmitted on a DLC or BSC line; 3270=received, 2780=received, 3780=transmitted; info indicates further detail, see Management Manual Appendix B.

93152

ENQ on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_51: A POLL or a WACK was received or transmitted on a DLC or BSC line; 3270=POLL received, 2780=WACK received, 3780=WACK transmitted; info indicates further detail. see Management Manual Appendix B.

93153

POLL or WACK on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_52: A SELECT packet was received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93154

SELECT received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_53: An ACK0 or a DLE0 was received or transmitted on a DLC or BSC line; 3270=ACK0 received, 2780=DLE0 received, 3780=DLE0 transmitted; info indicates further detail, see Management Manual Appendix B.

93155

ACK0 or DLE0 on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_54: An ACK1 or a DLE1 was received or transmitted on a DLC or BSC line; 3270=ACK1 received, 2780=DLE1 transmitted, 3780=DLE1 received; info indicates further detail, see Management Manual Appendix B.

93156

ACK1 or DLE1 on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_55: A NAK was received or transmitted on a DLC or BSC line; 3270=NAK received, 2780=NAK transmitted, 3780=NAK received; info indicates further detail, see Management Manual Appendix B.

93157

NAK on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_56: An EOT was received or transmitted on a DLC or BSC line; 3270=EOT received, 2780=EOT transmitted, 3780=EOT received; info indicates further detail, see Management Manual Appendix B.

93158

EOT on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_57: An RVI was received or transmitted on a DLC or BSC line; 3270=RVI received, 2780=RVI transmitted, 3780=RVI received; info indicates further detail, see Management Manual Appendix B.

93159

RVI on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_58: A TTD was received or transmitted on a DLC or BSC line; 3270=TTD received, 2780=TTD transmitted, 3780=TTD received; info indicates further detail, see Management Manual Appendix B.

93160

TTD on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_59: A WACK or DLE-EOT was received or transmitted on a DLC or BSC line; 3270=WACK received, 2780=DLE-EOT transmitted, 3780=DLE-EOT received; info indicates further detail, see Management Manual Appendix B.

93161

WACK or DLE-EOT on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_5A: A specific poll packet was received on a DLC or BSC line; for 3270 only; info indicates further detail, see Management Manual Appendix B.

93162

Specific poll packet received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_60: A single block of data was received without error on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93168

Single-block data received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_61: A first block of data was received without error on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93169

First-block data received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_62: An intermediate block of data was received without error on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93170

Intermediate-block data received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_63: A last block of data was received without error on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93171

Last-block data received on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_70: A message that was too long was received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93184

Message too long on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_71: A timeout occurred to a 2780/3780 device on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93185

Timeout occurred to 2780/3780 on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_77: No STX character was present in a received block on a DLC or BSC line; no response is generated; info indicates further detail, see Management Manual Appendix B.

93191

No STX character present on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_78: An ENQ was present in a data message; a NAK is transmitted; info indicates further detail, see Management Manual Appendix B.

93192

ENQ in data message on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_79: A timeout occurred during reception of a block from a 3270 device on a DLC or BSC line; a NAK is transmitted in data transfer mode; info indicates further detail, see Management Manual Appendix B.

93193

Timeout during receive from 3270 on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_80: A parity error was detected in a single block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93200

Parity error in single-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_81: A parity error was detected in a first block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93201

Parity error in first-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_82: A parity error was detected in an intermediate block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93202

Parity error in intermediate-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_83: A parity error was detected in a last block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93203

Parity error in last-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_90: A BCC error was detected in a single block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93216

BCC error in single-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_91: A BCC error was detected in a first block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93217

BCC error in first-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_92: A BCC error was detected in an intermediate block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93218

BCC error in intermediate-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_93: A BCC error was detected in a last block received on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93219

BCC error in last-block on DLC/BSC (from <Node X.25 Address>, info=<Info>)

minor

0C_97: A Reset occurred from the network on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93223

Reset occurred from network on DLC/BSC (from <Node X.25 Address>, info=<Info>)

normal

0C_98: A Protocol violation occurred on a DLC or BSC line; the VC is Cleared; info indicates further detail, see Management Manual Appendix B.

93224

Protocol violation on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0C_99: A reserved event for 2780/3780 devices occurred on a DLC or BSC line; info indicates further detail, see Management Manual Appendix B.

93225

Reserved event for 2780/3780 occurred on DLC/BSC (from <Node X.25 Address>, info=<Info>)

warning

0D_01: A multi-frame packet was received in the window guard region on an MLP line; a Restart is sent.

93329

Multi-frame in window guard region on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_02: A multi-frame packet was received outside the window on an MLP line; the frame is ignored.

93330

Multi-frame outside the window on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_03: An MT4 timeout occurred on an MLP line; the MLP bundle is taken down.

93331

Timeout of MT4 occurred on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_04: An MT1 timeout (lost-frame) occurred on an MLP line; a Restart is sent.

93332

Timeout of MT1 occurred on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_05: The MT4 timer was initiated on an MLP line.

93333

Timer MT4 initiated on MLP (from <Node X.25 Address>, line <Port Number>)

normal

0D_06: An invalid multi-frame with R=1 was received during Reset on an MLP line; Level2 and MLP are Reset.

93334

Invalid multi-frame (R=1) received on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_07: A multi-frame with R=1 was received during reset on an MLP line; the frame is ignored.

93335

Multi-frame (R=1) ignored on MLP (from <Node X.25 Address>, line <Port Number>)

minor

0D_08: An invalid multi-frame with C=1 was received during reset on an MLP line; Level2 and MLP are Reset.

93336

Invalid multi-frame (C=1) received on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_09: A multi-frame with C=1 was received during reset on an MLP line; the frame is ignored.

93337

Multi-frame (C=1) ignored on MLP (from <Node X.25 Address>, line <Port Number>)

minor

0D_0A: A multi-frame of length 2 was received on an MLP line; the frame is ignored.

93338

Multi-frame length=2 on MLP (from <Node X.25 Address>, line <Port Number>)

minor

0D_0B: A Multi-frame with (R=1) and (C=1) both TRUE were received on an MLP line; the frame is ignored.

93339

Multi-frame (R=1, C=1) received on MLP (from <Node X.25 Address>, line <Port Number>)

minor

0D_0C: A Reset was received on a multi-frame during data transfer on an MLP line; Level2 and MLP are Reset; if config parameter set=reset Level3.

93340

Reset Multi-frame during data transfer on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_0D: An MT3 timeout occurred on an MLP line.

93341

Timeout of MT3 occurred on MLP (from <Node X.25 Address>, line <Port Number>)

warning

0D_0E: A bundle came online on an MLP line.

93342

Bundle online on MLP (from <Node X.25 Address>, line <Port Number>)

normal

0D_0F: A bundle changed state on an MLP line; info indicates: line number within bundle, new state, line level state, lines in service on bundle.

93343

Bundle changed state on MLP (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0E_02: Line signal changed: Modem circuit 117 (StandBy) off, terminal circuit 114 (TxClk) off.

93586

Line signal 117/114 change on PSTN (from <Node X.25 Address>, line <Port Number>)

normal

0E_03: Line signal changed: Modem circuit 117 (StandBy) on, terminal circuit 114 (TxClk) off.

93587

Line signal 117/114 change on PSTN (from <Node X.25 Address>, line <Port Number>)

normal

0E_04: A Clear occurred due to VC being absent on a DLC or BSC line; the data path is Cleared.

93588

Clear if VC absent on PSTN (from <Node X.25 Address>, line <Port Number>)

normal

0E_05: A failure of type B1 occurred on a PSTN line, B1: modem unable to handle Call due to blacklisted numbers; the Call is Cleared; info indicates: diagnostic cause: 00 = not significant 02 = delayed number 04 = blacklisted number 05 = absence of tone 06 = remote subscriber busy 07 = remote subscriber absent 08 = remote subscriber is not a modem, number of digits in telephone number, telephone number.

93589

Failure type B1 on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0E_06: A failure of type A or C occurred on a PSTN line, A: local modem dialog problem, C: switched network unable to route Call; a subsequent Call attempt is made; info indicates: diagnostic cause: 00 = not significant 02 = delayed number 04 = blacklisted number 05 = absence of tone 06 = remote subscriber busy 07 = remote subscriber absent 08 = remote subscriber is not a modem.

93590

Failure type A/C on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0E_07: A failure of type B2 or D occurred on a PSTN line. B2: modem unable to handle Call due to delayed numbers from previous Call failure, D: remote subscriber cannot be connected; a subsequent Call attempt is made; info indicates: diagnostic cause: 00 = not significant 02 = delayed number 04 = blacklisted number 05 = absence of tone 06 = remote subscriber busy 07 = remote subscriber absent 08 = remote subscriber is not a modem, number of digits in telephone number, telephone number.

93591

Failure type B2/D on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0E_08: A failure of type E occurred on a PSTN line, E: remote subscriber connected but frame or packet level not setup (Call collision); the data path is Cleared; info indicates: diagnostic cause: 00 = not significant 02 = delayed number 04 = blacklisted number 05 = absence of tone 06 = remote subscriber busy 07 = remote subscriber absent 08 = remote subscriber is not a modem.

93592

Failure type E on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

minor

0E_0A: A Backup or Overflow link was established on a PSTN line; enters the Call state; info indicates: FF marker, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, MLP bundle number (FF=not significant).

93594

Backup link established on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0E_0B: An attempt to establish a Backup or Overflow link on a PSTN line failed; enters the Idle state; info indicates: FF marker, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, MLP bundle number (FF=not significant), failure cause.

93595

Backup link failed on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

0E_0C: Notification of a Switched line disconnection occurred on a PSTN line; info indicates: FF marker, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address.

93596

Switched line disconnection on PSTN (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0F_41: An outgoing connection is in progress on a VC/ESV line; a Transport Request is sent; info indicates: Logical Channel number.

93905

Outgoing connection in progress on VC/ESV (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0F_42: An incoming connection is in progress on a VC/ESV line; a Response is sent to a Transport Request; info indicates: Logical Channel number.

93906

Incoming connection in progress on VC/ESV (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0F_43: The data transfer state was entered on a VC/ESV line; node is ready to transfer data; info indicates: Logical Channel number.

93907

Enter data transfer on VC/ESV (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0F_44: An outgoing clear signal was received on a VC/ESV line; a data transfer Transport Request is asserted and node awaits incoming Clear signal Confirmation; info indicates: Logical Channel number.

93908

Outgoing Clear signal received on VC/ESV (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

0F_45: An incoming Clear signal was received on a VC/ESV line; data transfer is Cleared to subscriber and node awaits outgoing Clear signal Confirmation; info indicates: Logical Channel number.

93909

Incoming Clear signal received on VC/ESV (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

10_00: Data Resynchronization occurred on a VC/N4 line.

94096

Data Resynchronization on VC/N4 (from <Node X.25 Address>)

normal

10_01: Resynchronization of terminated data occurred on a VC/N4 line.

94097

Terminated data Resynchronization on VC/N4 (from <Node X.25 Address>)

normal

10_02: Retransmission of terminated data occurred on a VC/N4 line.

94098

Retransmission of terminated data on VC/N4 (from <Node X.25 Address>)

normal

10_10: The maximum number of data retransmissions was exhausted on a VC/N4 line; the line is disconnected.

94112

Maximum retransmissions exhausted on VC/N4 (from <Node X.25 Address>)

warning

10_20: A TPDU DT with an unexpected number was received on a VC/N4 line; the line is disconnected.

94128

TPDU DT with unexpected number on VC/N4 (from <Node X.25 Address>)

warning

10_21: A TPDU ED with an unexpected number was received on a VC/N4 line; the line is disconnected.

94129

TPDU ED with unexpected number on VC/N4 (from <Node X.25 Address>)

warning

10_22: A TPDU EA was received not corresponding with a TPDU ED on a VC/N4 line; the line is disconnected.

94130

TPDU EA not corresponding with an ED on VC/N4 (from <Node X.25 Address>)

warning

10_23: A TPDU RJ or TPDU AK was received with an expected number or the next TPDU DT outside the valid window on a VC/N4 line; the line is disconnected.

94131

TPDU DT expected number outside window on VC/N4 (from <Node X.25 Address>)

warning

10_25: A reference number in a received frame is unknown on a VC/N4 line; the line is disconnected.

94133

Reference number unknown on VC/N4 (from <Node X.25 Address>)

warning

10_26: A TPDU format error occurred on a VC/N4 line; the line is disconnected.

94134

TPDU format error on VC/N4 (from <Node X.25 Address>)

warning

10_27: An unknown TPDU was received on a VC/N4 linel the line is disconnected.

94135

Unknown TPDU on VC/N4 (from <Node X.25 Address>)

warning

10_51: A transport connection was established (calling side) on a VC/N4 line; a transport connection Confirmation is sent and node is ready for data transfer.

94177

Transport connection established (calling side) on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_52: A transport connection was established (called side) on a VC/N4 line; the node is ready for data transfer.

94178

Transport connection established (called side) on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_53: A TPDU DR was received on a VC/N4 line; a TPDU DC is sent.

94179

TPDU DR received on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_54: A TPDU DC was received on a VC/N4 line; a "Connection Disconnect" is sent.

94180

TPDU DC received on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_55: A protocol error occurred on a VC/N4 line; a "Transport Disconnect Indication" is sent.

94181

Protocol error on VC/N4 (from <Node X.25 Address>, line <Port Number>)

warning

10_56: Resynchronization 56 occurred on a VC/N4 line; the TPDU CR is re-transmitted.

94182

Resynchronization 56 on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_57: Resynchronization 57 occurred on a VC/N4 line; flag is positioned for data resynchronization.

94183

Resynchronization 57 on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_58: Resynchronization 58 occurred on a VC/N4 line; the TPDU CR is re-transmitted.

94184

Resynchronization 58 on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_59: Resynchronization 59 occurred on a VC/N4 line; the TPDU CR is re-transmitted.

94185

Resynchronization 59 on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_5A: A network connection was disconnected on a VC/N4 line; a "Transport Disconnect Indication" is sent.

94186

Network connection disconnected on VC/N4 (from <Node X.25 Address>, line <Port Number>)

normal

10_60: No more Logical Channel resources are available on a VC/N4 line; the line is disconnected.

94192

No more LC resources on VC/N4 (from <Node X.25 Address>)

minor

10_61: No more reference numbers are available on a VC/N4 line; the line is disconnected.

94193

No more reference numbers on VC/N4 (from <Node X.25 Address>)

minor

11_00: The network connected without error on a VC/IR line.

94352

Network connected on VC/IR (from <Node X.25 Address>)

normal

11_01: Re-establishment succeeded on a VC/IR line.

94353

Re-establishment succeeded on VC/IR (from <Node X.25 Address>)

normal

11_02: The network disconnected without error on a VC/IR line.

94354

Network disconnected on VC/IR (from <Node X.25 Address>)

normal

11_05: A Clear signal was received from the network on a VC/IR line; the line is re-established.

94357

Clear signal from network on VC/IR (from <Node X.25 Address>)

warning

11_06: A Reset was received from the network on a VC/IR line.

94358

Reset from network on VC/IR (from <Node X.25 Address>)

normal

11_07: A Clear was received while in the opened state on a VC/IR line; the line is disconnected.

94359

Clear in opened state on VC/IR (from <Node X.25 Address>)

normal

11_10: The maximum number of Call retries was reached on a VC/IR line; the line is disconnected.

94368

Maximum Call retries exceeded on VC/IR (from <Node X.25 Address>)

warning

11_11: The Wait-to-Reconnect timer expired on a VC/IR line; the line is disconnected.

94369

Wait-to-Reconnect timeout on VC/IR (from <Node X.25 Address>)

warning

11_15: A Clear signal was received in error on a VC/IR line; IR protocol error; the line is disconnected.

94373

Clear signal in error on VC/IR (from <Node X.25 Address>)

warning

11_20: There was no TPDU PI in an incoming Call on a VC/IR line; the line is disconnected.

94384

No TPDU PI in incoming Call on VC/IR (from <Node X.25 Address>)

warning

11_21: The NSAP (calling) is absent or in error on a VC/IR line; the line is disconnected.

94385

NSAP error on VC/IR (from <Node X.25 Address>)

warning

11_22: An attempt to restore an unknown connection was made on a VC/IR line; the line is disconnected.

94386

Attempt to restore unknown connection on VC/IR (from <Node X.25 Address>)

warning

11_23: The Call data was not compatible oe was insufficient on a VC/IR line; the line is disconnected.

94387

Call data error on VC/IR (from <Node X.25 Address>)

warning

11_24: There was no Call data present in a Call on a VC/IR line; the line is disconnected.

94388

No Call data on VC/IR (from <Node X.25 Address>)

warning

11_25: A Call data Confirmation was received with inconsistent information on a VC/IR line; the line is disconnected.

94389

Inconsistent Call data Confirmation on VC/IR (from <Node X.25 Address>)

warning

11_26: Data was received while waiting for Call data Confirmation on a VC/IR line; the line is disconnected.

94390

Data received while awaiting Call Confirmation on VC/IR (from <Node X.25 Address>)

warning

11_30: A repeated Call without error was received during disconnect on a VC/IR line; the line is disconnected.

94400

Repeated Call during disconnect on VC/IR (from <Node X.25 Address>)

warning

11_31: A Clear signal was received while in the Invitation-to-Clear state on a VC/IR line; the line is re-established then disconnected.

94401

Clear signal during Invitation-to-Clear on VC/IR (from <Node X.25 Address>)

warning

11_32: The remote side was cleared from the network connection on a VC/IR line.

94402

Remote side cleared from network on VC/IR (from <Node X.25 Address>)

warning

11_33: An Invitation-to-Clear was received while in the Opened state on a VC/IR line; the line is disconnected.

94403

Invitation-to-Clear in Opened state on VC/IR (from <Node X.25 Address>)

warning

11_50: There are no more Logical Channels available on a VC/IR line; the line is disconnected.

94432

No more Logical Channels available on VC/IR (from <Node X.25 Address>)

warning

11_51: The network connection reference was lost on a VC/IR line; the line is disconnected.

94433

Network connection reference lost on VC/IR (from <Node X.25 Address>)

warning

12_00: The physical Line Level is down on an ISDN line; all calls are interrupted, all line levels are down.

94608

Line Level down on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

major

12_01: The physical Line Level is up on an ISDN line; the S-interface is activated, the TEI is allocated.

94609

Line Level up on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

normal

12_02: A Physical Management activation indication was received on an ISDN line; S0 interface is activated, data transfer is now possible.

94610

Physical Management activation on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

normal

12_03: A Physical Management inactivation indication was received on an ISDN line; S0 interface is inactivated, data transfer is no longer possible.

94611

Physical Management inactivation on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_04: A Physical Management level error signal indication occurred on an ISDN line; cause is loss of frame locking or loss of synchronization.

94612

Physical Management error signal on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_05: A Physical Management level error recovery indication occurred on an ISDN line; enters the Active state.

94613

Physical Management error recovery on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

normal

12_06: A CRC error occurred on an ISDN line; the frame is ignored.

94614

CRC error on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_07: An ABORT sequence was received on an ISDN line; the frame is ignored.

94615

ABORT sequence received on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_08: A Reset error occurred on an ISDN line; the frame is ignored.

94616

Reset error on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_09: An Overrun/Underrun error occurred on an ISDN line; the frame is ignored.

94617

Overrun/Underrun on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_0A: The current frame was received correctly on an ISDN line but the previous frame was lost; the frame is ignored.

94618

Previous frame lost on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

warning

12_0B: A CRC error occurred on the current frame on an ISDN line and the previous frame was lost; the frame is ignored.

94619

CRC error and previous frame lost on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_0C: An ABORT sequence occurred on the current frame on an ISDN line and the previous frame was lost; the frame is ignored.

94620

ABORT sequence and previous frame lost on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_0D: A Reset error occurred on the current frame on an ISDN line and the previous frame was lost; the frame is ignored.

94621

Reset error and previous frame lost on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_0E: An Overrun occurred on the current frame on an ISDN line and the previous frame was lost; the frame is ignored.

94622

Overrun and previous frame lost on ISDN-Line (from <Node X.25 Address>, line <Port Number>)

minor

12_30: A Supervisory frame with F=1 was received on an ISDN line which is in state 7; the frame is processed.

94656

Received S-frame (F=1) in state 7 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_31: A DM frame with F=1 was received on an ISDN line which is in state 7 or 8; the frame is ignored.

94657

Received DM (F=1) in state 7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_32: A UA frame with F=1 was received on an ISDN line which is in state 4,7 or 8; the TEI is deleted.

94658

Received UA (F=1) in state 4/7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_33: A UA frame with F=0 was received on an ISDN line which is in state 4,5,6,7 or 8; the TEI is deleted.

94659

Received UA (F=0) in state 4/5/6/7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_34: A DM frame with F=0 was received on an ISDN line which is in state 7 or 8; Level 2 is re-initialized.

94660

Received DM (F=0) in state 7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_35: A SABME frame was received on an ISDN line which is in state 7 or 8; a UA is sent and state becomes 7.

94661

Received SABME in state 7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_36: SABME Retries exceeded parameter N200 on an ISDN line which is in state 5; state becomes 4.

94662

SABME retries in state 5 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_37: DISC retries exceeded parameter N200 on an ISDN line which is in state 6; state becomes 4.

94663

DISC retries in state 6 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_38: Poll status was received on an ISDN line which is in state 8; level 2 is re-initialized.

94664

Poll status in state 8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_39: An N(R) error occurred on an ISDN line which is in state 7 or 8; level 2 is re-initialized.

94665

N(R) error in state 7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_3A: An FRMR frame was received on an ISDN line which is in state 7 or 8; level 2 is re-initialized.

94666

FRMR received in state 7/8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_3B: An unused frame was received on an ISDN line which is in state 4,5,7 or 8; level 2 is re-initialized if the state is not 4.

94667

Unused frame received on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_3C: An unauthorized I-field was received on an ISDN line which is in one of states 4-8; the frame is ignored.

94668

Unauthorized I-field in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_3D: A frame of the wrong size was received on an ISDN line which is in one of state 4-8; level 2 is re-initialized if not in state 4.

94669

Frame wrong size in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_3E: An N201 error occurred on an ISDN line which is in one of states 4-8; level 2 is re-initialized if not in state 4.

94670

N201 error in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_3F: A frame with a 1-byte address field was received on an ISDN line which is in one of states 4-8; the frame is ignored.

94671

Frame with 1-byte address in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_40: A frame which is too short was received on an ISDN line which is in one of states 4-8; the frame is ignored.

94672

Frame too short in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_41: A frame with an incorrect SAPI was received on an ISDN line which is in one of states 4-8; the frame is ignored.

94673

Frame with incorrect SAPI in state 4-8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_42: A frame with an address field of more than 2 bytes was received on an ISDN line; the frame is ignored.

94674

Frame with more than 2-byte address field on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_43: A frame with an unknown SAPI/TEI combination was received on an ISDN line; the frame is ignored.

94675

Frame with unknown SAPI/TEI on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_44: An N(S) error occurred on an ISDN line which is in state 7 or 8; the frame is processed.

94676

N(S) error in states 7, 8 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_45: A Control frame with C=0 was received on an ISDN line; the frame is ignored.

94677

Control frame with C=0 on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

minor

12_46: A Fixed TEI deletion error occurred on an ISDN line; user must reset line; network suspects a duplicate assignment of TEI on the bus.

94678

Fixed TEI deletion on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

warning

12_4E: Multiple frame mode is set on an ISDN line; level 2 enters state 7.

94686

Multiple frame mode set on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_4F: Multiple frame mode is reset on an ISDN line; level 2 enters state 4.

94687

Multiple frame mode reset on ISDN-Frame (from <Node X.25 Address>, line <Port Number>)

normal

12_60: A Protocol level D event occured on an ISDN line; see the event list for ISDN Protocol D in the manual.

94704

Protocol level D event on ISDN-Frame (from <Node X.25 Address>)

normal

12_90: The content of an obligatory Element Information (Ei) is invalid on an ISDN line; the Call is aborted.

94752

Content of Ei in error on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_91: Primary access instead of basic access occurred on an ISDN line; the Call is aborted.

94753

Primary access instead of basic access on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_92: Channel B is not available for a new incoming call on an ISDN line; the Call is aborted.

94754

Channel B unavailable for incoming call on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_93: Element Information (Ei) of higher layers is not compatible on an ISDN line; the Call is aborted.

94755

Higher layer Ei not compatible on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_94: The Calling E.164 address is not in the list in a Call Reject on an ISDN line; the Call is aborted.

94756

Calling E.164 address not in list on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_95: A timeout expired or a problem was detected by lower layers on an ISDN line; the Call is aborted.

94757

Timeout expired on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_96: A Call was refused due to S0 interface behavior on an ISDN line; the Call is aborted.

94758

Call refused due to S0 behavior on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_97: A Call was refused due to S0 interface selection on an ISDN line; the Call is aborted.

94759

Call refused due to selected S0 on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_98: Row Range in C10 is inconsistent on an ISDN line; the Call is aborted.

94760

Row Range in C10 inconsistent on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_99: An MLP Call was rejected on an ISDN line; the Call is aborted.

94761

MLP Call rejected on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A0: A translation error from X.121 to E.164 addresses occurred on an ISDN line; the Call is aborted.

94768

Address translation error X.121 to E.164 on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A1: There is no channel available for an outgoing call on an ISDN line; the Call is aborted.

94769

Channel unavailable for outgoing call on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A2: There is insufficient context information available on a Call on an ISDN line; the Call is aborted.

94770

Insufficient context on Call on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A3: The maximum number of VCs were exceeded on an ISDN line; the VC is aborted on overflow to another channel.

94771

Maximum VCs exceeded on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A4: The position of profile C30 is inconsistent on an ISDN line; the Call is aborted.

94772

Profile C30 position inconsistent on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A5: The content of profile C30 is inconsistent on an ISDN line; the Call is aborted.

94773

Profile C30 content inconsistent on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A6: The B-channel is not configured on an ISDN line; the Call is aborted.

94774

B-channel not configured on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A7: Backup attempt retries were exceeded on an ISDN line; the Call is aborted.

94775

Backup retries exceeded on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_A8: Backup attempt is terminated on an ISDN line; the Call is aborted.

94776

Backup attempts terminated on ISDN-Call (from <Node X.25 Address>, line <Port Number>)

warning

12_B0: A B-channel disconnect indication occurred on an ISDN line; line is channel D or LLP number; info indicates: channel B line number, E.164 address of remote user.

94784

B-channel disconnect indication on ISDN-Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

12_B1: A B-channel connect indication occurred on an ISDN line; line is channel D or LLP number; info indicates: channel B line number, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, main line number of bundle (FF = not significant).

94785

B-channel connect indication on ISDN-Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

12_B2: A B-channel connect indication requested by remote party occurred on an ISDN line; line is channel D or LLP number; info indicates: channel B line number, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, main line number of bundle (FF = not significant).

94786

B-channel connect remote indication on ISDN-Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

12_B3: A connection request (local or remote) failed on an ISDN line; line is channel D or LLP number; info indicates: channel B line number, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, main line number of bundle (FF = not significant).

94787

Connect failure on ISDN-Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

12_B4: A disconnect request failed on an ISDN line; line is channel D or LLP number; info indicates: call reference number, channel B line number, E.164 address of remote user.

94788

Disconnect failure on ISDN-Call (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

13_01: A Rerouting request was transmitted transparently on X.29, parameter DR2 is present with length=0; the Call is transmitted transparently.

94865

Rerouting request transmitted transparently on X.29 (from <Node X.25 Address>, line <Port Number>)

normal

13_02: A Rerouting request was refused due to a syntax error or a parameter not being processed on X.29; a negative routing report is transmitted.

94866

Rerouting request refused due to syntax error on X.29 (from <Node X.25 Address>, line <Port Number>)

warning

13_03: A Clear was received on a transmitted Call due to a rerouting request on X.29; a negative routing report is transmitted.

94867

Clear received due to rerouting request on X.29 (from <Node X.25 Address>, line <Port Number>)

normal

13_04: A Clear was received on a transmitted Call due to receipt of a new X.29 selection or a reconnect command.

94868

Clear received due to X.29 select (from <Node X.25 Address>, line <Port Number>)

normal

14_01: A transmission failure occurred on a Bridge / Router line.

95121

Transmission failure on B/R (from <Node X.25 Address>, line <Port Number>)

warning

14_02: A CAM full indication occurred on a Bridge / Router line.

95122

CAM full indication on B/R (from <Node X.25 Address>, line <Port Number>)

normal

14_03: The Bridge node is now online.

95123

Bridge online (from <Node X.25 Address>, line <Port Number>)

normal

14_04: The Bridge node is now offline.

95124

Bridge offline (from <Node X.25 Address>, line <Port Number>)

warning

14_05: The SLL Bridge is now online; info indicates: 1byte = free, 2bytes = SLL number, 2bytes = DNIC of remote equipment, 1byte = ZO of remote equipment, 1byte = remote subscriber, 1byte = local subscriber, 1byte = number of SLL handler line, 1byte = encapsulation type.

95125

SLL Bridge online (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

14_06: The SLL Bridge is now offline; info indicates: 1byte = free, 2bytes = SLL number, 2bytes = DNIC of remote equipment, 1byte = ZO of remote equipment, 1byte = remote subscriber, 1byte = local subscriber, 1byte = number of SLL handler line, 1byte = encapsulation type.

95126

SLL Bridge offline (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_07: The Bridge / Router is now synchronized; info indicates: 2bytes = SLL number.

95127

Node synchronized on B/R (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

14_08: A duplicate IP address or Ethernet address was detected in an ARP packet; info indicates: 1byte = free, 4bytes = IP address of router, 4bytes = IP address of first station, 4bytes = IP address of second station, 6bytes = Ethernet address of first station, 6bytes = Ethernet address of second station.

95128

Duplicate IP or Ethernet address on B/R (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_09: The address resolution process run on an address in an ARP packet failed; info indicates: 1byte = free, 4bytes = IP address of router, 4bytes = IP address not resolved.

95129

Address resolution failed on B/R (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_0A: An IP Router error occurred; info indicates: 1byte = free, 4bytes = IP address of router, 1byte = error code.

95130

IP Router error (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_0B: The IP Router is now online; info indicates: 1byte = free, 4bytes = IP address of router.

95131

IP Router online (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

14_0C: The IP Router is now offline.

95132

IP Router offline (from <Node X.25 Address>, line <Port Number>)

warning

14_0D: An unknown destination address was received by the IP Router; info indicates: 1byte = free, 4bytes = IP address of router, 4bytes = IP addres in fault, 4bytes = source IP address of datagram, 1byte = error code: 00 = ICMP net unreachable, 01 = ICMP host unreachable, 02 = ICMP protocol unreachable.

95133

IP Router bad destination address (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_0E: The IP Router encountered a timeout; info indicates: 1byte = free, 4bytes = IP address of router, 4bytes = destination IP address of datagram, 4bytes = source IP address of datagram, 1byte = error code: 00 = ICMP time-to-live in transit.

95134

IP Router timeout exceeded (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_0F: An error occurred on an IP Router SLL; info indicates: 1byte = free, 4bytes = IP address of router, 2bytes = SLL number in fault, 2bytes = DNIC of remote equipment, 1byte = ZO of remote equipment, 1byte = remote subscriber, 1byte = error code: 01 = fast-select configuration error, 05 = error in Call data, 0A = dynamic connection fault.

95135

IP Router SLL error (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

14_10: A LAN or a WAN interface is now online; info indicates: 1byte = free, 4bytes = IP address of router, 2bytes = SLL number (0 if LAN), 2bytes = DNIC of remote equipment (0 if LAN), 1byte = ZO of remote equipment (0 if LAN), 1byte = remote subscriber (0 if LAN), 1byte = local subscriber (0 if LAN), 1byte = number of SLL handler line, 1byte = encapsulation type (0 if LAN).

95136

LAN/WAN interface online on B/R (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

14_11: A LAN or a WAN interface is now offline; info indicates: 1byte = free, 4bytes = IP address of router, 2bytes = SLL number (0 if LAN), 2bytes = DNIC of remote equipment (0 if LAN), 1byte = ZO of remote equipment (0 if LAN), 1byte = remote subscriber (0 if LAN), 1byte = local subscriber (0 if LAN), 1byte = number of SLL handler line, 1byte = encapsulation type (0 if LAN).

95137

LAN/WAN interface offline on B/R (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

15_00: A Connection was established on a DLC or MFR line; the SVC is setup.

95376

Connection established on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

normal

15_01: A Connection was cleared on a DLC or MFR line; the SVC is Cleared.

95377

Connection cleared on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

normal

15_02: A frame with an unknown DLCI was received on a DLC or MFR line; the frame is ignored.

95378

Unknown DLCI on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

minor

15_03: Frame re-assembly initiation has occurred on a DLC or MFR line.

95379

Start frame re-assembly on DLC/MFR (from <Node X.25 Address>)

normal

15_04: Transmission of re-assembled frames has stopped on a DLC or MFR line.

95380

Re-assembled frame transmission stopped on DLC/MFR (from <Node X.25 Address>)

normal

15_05: The congestion bits are being set on a DLC or MFR line.

95381

Setting congestion bits on DLC/MFR (from <Node X.25 Address>)

normal

15_06: Selective frame dropping is occurring on a DLC or MFR line.

95382

Selective frame drop on DLC/MFR (from <Node X.25 Address>)

warning

15_07: All frames are being dropped on a DLC or MFR line.

95383

Dropping all frames on DLC/MFR (from <Node X.25 Address>)

warning

15_08: Dropping all frames after data frame rejection threshold exceeded; (see parameter C2R3P0).

95384

Data frame rejection threshold exceeded on DLC/MFR (from <Node X.25 Address>)

warning

15_10: A frame that is too short was received on a DLC or MFR line; the frame is ignored.

95392

Frame too short on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

minor

15_20: A frame too that is long was received on a DLC or MFR line; the frame is ignored.

95408

Frame too long on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

minor

15_30: A packet that is too short was received from the X.25 layer.

95424

Packet too short received from X.25 on DLC/MFR (from <Node X.25 Address>)

warning

15_40: A packet that is too long was received from the X.25 layer.

95440

Packet too long received from X.25 on DLC/MFR (from <Node X.25 Address>)

warning

15_50: An unexpected end of de-segmentation occurred on a DLC or MFR line; the next SEP could not be extracted due to the remaining number of bytes being less than 2.

95456

Unexpected end of de-segmentation on DLC/MFR (from <Node X.25 Address>)

warning

15_60: The SEP extracted is inconsistent due to the length (SEP+data) being less than the remaining number of bytes.

95472

Extracted SEP inconsistent on DLC/MFR (from <Node X.25 Address>)

warning

15_8C: A CRC error occurred on a DLC or MFR line; the frame is ignored.

95516

CRC error on DLC/MFR (from <Node X.25 Address>, line <Port Number>)

minor

16_00: The compression function is not available on the requested VC; the VC is Cleared if compression is a required function otherwise the VC is established without compression.

95632

Compression not available on requested VC (from <Node X.25 Address>)

warning

16_01: The compression function is enabled on the VC, in the direction from the called to the caller address; the VC is established.

95633

Compression enabled from called to caller on VC (from <Node X.25 Address>)

normal

16_02: The compression function is enabled on the VC, in the direction from the caller to the called address; the VC is established.

95634

Compression enabled from caller to called on VC (from <Node X.25 Address>)

normal

16_03: The compression function is enabled on the VC in both directions, to caller and to called; the VC is established.

95635

Compression enabled bi-directional on VC (from <Node X.25 Address>)

normal

16_04: The compression function is Reset due to an internal cause; the VC is Reset.

95636

Compression Reset due to internal cause (from <Node X.25 Address>)

warning

16_05: The compression function is Reset due to an external cause; the VC is Reset.

95637

Compression Reset due to external cause (from <Node X.25 Address>)

warning

16_06: The data encryption function is disabled on the VC; the VC is Cleared of data encryption is a required function, otherwise the VC is established without data encryption.

95638

Data encryption disabled on VC (from <Node X.25 Address>)

warning

16_07: The data encryption function is enabled on the VC; the VC is established.

95639

Data encryption enabled on VC (from <Node X.25 Address>)

normal

17_01: A request to connect the line in the X.121 direction was received on a DLM line; info indicates: FF marker, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, MLP bundle number (FF=not significant).

95889

Connect line toward X.121 on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

17_02: A notification of failure to connect a switched line for either a local or remote cause was received on a DLM line. info indicates: failure source: 0=remote 1=local, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, MLP bundle number (FF=not significant), failure cause.

95890

Connect failed local or remote on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

17_03: A notification of connection completed on a switched line that is already established was received on a DLM line; info indicates: FF marker, E.164 address length, E.164 address, AA marker, X.121 address length, X.121 address, AA marker, MLP bundle number (FF=not significant).

95891

Connect completed on switched line on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

17_04: A notification of a switched line being assigned as part of a Destination Line changeover or reconnection was received on a DLM line; line is Destination number; info indicates: source line number, cause indication, diagnostic indication.

95892

Switched line assigned on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

17_05: A request to assign a Source Line for Destination Line changeover or reconnection was received on a DLM line; line is Source number; info indicates: destination line number.

95893

Source line requested on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

17_06: A request to close all Source Lines not in a bundle in the indicated direction was received on a DLM line; line is line number that caused Reset; info indicates: X.121 address length, X.121 address.

95894

Request to close SLs not in bundle on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

17_07: A notification of a software incident occurred on a DLM line; info indicates: incident number.

95895

Software incident on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

warning

17_08: A notification of low threshold on a bundle occurred on a DLM line; line is bundle number; info indicates: number of lines in bundle, list of lines in bundle, FF marker.

95896

Low bundle threshold on DLM (from <Node X.25 Address>, line <Port Number>, info=<Info>)

normal

18_00: A call was made to the Configurator (CFG); the configurator is awaiting a keyword; info indicates: call request packet.

96144

Configurator called in CFG (from <Node X.25 Address>, info=<Info>)

normal

18_01: A CRC error occurred during configuration; the Configuration RAM is restored.

96145

CRC error in CFG (from <Node X.25 Address>)

warning

18_02: The size of the configuration is too large; info indicates: compressed size sent.

96146

Configuration size too large in CFG (from <Node X.25 Address>, info=<Info>)

minor

18_03: The EEPROM is being archived by the Configurator (CFG).

96147

EEPROM archiving in CFG (from <Node X.25 Address>)

normal

18_04: The Configuration RAM is being restored.

96148

Configuration RAM restored in CFG (from <Node X.25 Address>)

normal

18_05: A Selective Reset occurred under Configurator control.

96149

Selective Reset in CFG (from <Node X.25 Address>)

normal

18_06: A line was created by the Configurator.

96150

Line creation in CFG (from <Node X.25 Address>, line <Port Number>)

normal

18_07: A line was deleted by the Configurator.

96151

Line deletion in CFG (from <Node X.25 Address>, line <Port Number>)

normal

18_08: The line type was changed by the Configurator.

96152

Line type changed in CFG (from <Node X.25 Address>, line <Port Number>)

normal

18_09: A network Clear or abnormal Clear occurred during configuration; normal termination of PAD command includes Clear; info indicates: cause of Clear, diagnostic of Clear.

96153

Network Clear in CFG (from <Node X.25 Address>, info=<Info>)

normal

18_10: The configuration RAM was copied to the operational RAM on the indicated module.

96160

Configuration RAM copied to operational RAM in CFG (from <Node X.25 Address>, module <Port Number>)

normal

18_14: Download to the indicated module was refused by the Configurator due to an unauthorized user access.

96164

Download refused: unauthorized user in CFG (from <Node X.25 Address>, module <Port Number>)

warning

18_15: Download to the indicated module was refused by the Configurator due to no buffer memory being available.

96165

Download refused: no buffers in CFG (from <Node X.25 Address>, module <Port Number>)

minor

18_16: Download to a module was initiated by the Configurator.

96166

Download initiated in CFG (from <Node X.25 Address>)

normal

18_17: Download to the indicated module was terminated by the Configurator.

96167

Download terminated in CFG (from <Node X.25 Address>, module <Port Number>)

normal

18_18: Download to a module was completed without error by the Configurator.

96168

Download completed without error in CFG (from <Node X.25 Address>)

normal

18_19: Download to the indicated module was refused by the Configurator due to no memory resources and maximum RAM size is less than 2MB.

96169

Download refused: no RAM in CFG (from <Node X.25 Address>, module <Port Number>)

minor

18_1E: A System Reset of the indicated module was initiated by the Configurator from the Flash PROM copy of the software.

96174

System Reset initiated from FPROM in CFG (from <Node X.25 Address>, module <Port Number>)

normal

18_1F: A System Reset of the indicated module was initiated by the Configurator from the RAM copy of the software.

96175

System Reset initiated from RAM in CFG (from <Node X.25 Address>, module <Port Number>)

normal

18_20: A download or upload of a configuration was initiated by the Configurator.

96176

Configuration download or upload initiated in CFG (from <Node X.25 Address>)

normal

19_00: A reception error occurred on a frame in the Configurator; the frame is ignored.

96400

Reception error on frame in CFG (from <Node X.25 Address>)

minor

19_01: A protocol error occurred on a frame in the Configurator; the frame is ignored.

96401

Protocol error in CFG (from <Node X.25 Address>)

minor

19_02: A reliability error occurred on a frame in the Configurator.

96402

Reliability error in CFG (from <Node X.25 Address>)

minor

19_03: Transfer of configuration data is enabled by the Configurator.

96403

Data transfer enabled in CFG (from <Node X.25 Address>)

normal

19_04: Transfer of configuration data is disabled by the Configurator.

96404

Data transfer disabled in CFG (from <Node X.25 Address>)

warning

19_05: Transmission of configuration data encountered an error; interface clocking may be the wrong rate or not connected.

96405

Transmission error in CFG (from <Node X.25 Address>)

warning

19_06: A DLCI was not configured due to the PLL structure not being found.

96406

DLCI not configured in CFG (from <Node X.25 Address>)

warning

19_07: An event occurred relating to the PLL structure in the Configurator.

96407

PLL structure event in CFG (from <Node X.25 Address>)

warning

19_09: There is an inconsistency in the CLASS 13 configuration; the default values from Profile 84 are used.

96409

CLASS 13 inconsistency in CFG (from <Node X.25 Address>)

minor