Table Of Contents
P
parameter (ccn application)
To set the value for a CCN application parameter, use the parameter command in Cisco Unity Express configuration application mode. This command does not have a no form.
parameter parameter-name "value"
Syntax Description
Command Modes
Configuration application
Command History
Usage Guidelines
Use the parameter command to change or set the value of an application parameter.
Examples
The following examples sets the value of the MaxRetry parameter to 6:
se-10-0-0-0# config t
se-10-0-0-0(config)# ccn application autoattendant
se-10-0-0-0(config-application)# parameter MaxRetry "6"
se-10-0-0-0(config-application)# end
se-10-0-0-0(config)# exit
Related Commands
Command DescriptionConfigures the CCN applications, such as voice mail and auto attendant.
Displays the CCN application details.
Posted: Fri Jan 13 04:08:44 PST 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.