Table Of Contents
Cisco Systems Hardware and Software Requirements
PBX Hardware and Software Requirements
Calling Name and Number feature
Configuring the Siemens Hicom 330 E PBX
Siemens Hicom 330 E PBX Configuration Menus and Commands
Configuring the Cisco CallManager
Siemens Hicom 330 E Software release
Cisco 2621 Router Configuration
Application Note
Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 2621-E1 PRI-NET5 Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager using Cisco 2621-E1 PRI-NET5 Gateway.
Integration Description
Connectivity is achieved by using the ETSI standard PRI protocol. The Siemens Hicom 330 E can be configured as either NETWORK or USER side.
Cisco Systems Hardware and Software Requirements
•Hardware (Cisco 2621 Gateway): 2MFT E1 Port
•Software: CallManager Release 3.1
PBX Hardware and Software Requirements
•Hardware: DIU-N2
•Software: Version 3.1
Features Supported
Key Features Supported
Calling/Called Number
Key Features Not Supported
Calling/Called Name
Limitations
Calling Name and Number feature
•Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E PBX.
•When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called Number is displayed on both phones after the call is answered as expected.
•When calling from Siemens digital phone to Cisco 7960 IP phone, the IP phone displays Connected Number after the call is answered. The Siemens phone however does NOT get updated when the call is answered. It displays the numbers being dialed instead. (i.e. Access Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.
Network Topology
Figure 1 Basic Setup
Configuration
Configuring the Siemens Hicom 330 E PBX
Use the following steps to configure the Siemens Hicom 330 E PBX.
Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.
Step 2. Add the new trunk board using BCSU.
Step 3. Configure Class of Trunk using COT.
Step 4. Configure Class of Parameter for device handler using COP.
Step 5. Configure Class of Service using COSSU.
Step 6. Add the new trunk group access code using BUEND.
Step 7. Configure trunk using TDCSU.
Step 8. Configure Reference Clock using REFTA.
Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.
Step 10. Configure LCR Out-dial Rules using LODR.
Siemens Hicom 330 E PBX Configuration Menus and Commands
Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.
<dis-wabe
TYPE = gen
CD =
DPLN = 0;
DIS-WABE:GEN,,0;
H500: AMO WABE STARTED
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 001 - 002 |* ..... ..... ..... ..... ..| NETRTE | |
| 11 |. ..... ..... ..... ....* ..| MBKY | |
| 3001 |. .**** ***** **... ..... ..| STN | R |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 3007 |. ..... ..... ..... ....* ..| MBKY | |
| 3007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 4100 - 4500 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 72 |
| | | |DNNO 1- 1-702 |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 5000 - 5007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 5008 - 5009 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 99 |
| | | |DNNO 1- 1- 99 |
| 5010 |. .**** *.*** **... ..... ..| ATNDIND | |
| 800 |. ..... *...* **... ..... ..| ATNDDID | |
| 854 |. .**** ***** **... ..... ..| NETW | R |
| | | |DESTNO 2 |
| | | |DNNO 0- 0- 0 |
| *66 |. ....* ..... ..... ..... ..| SIGNON | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *91 |. ....* ....* ..... ..... ..| MBOFF | |
| #66 |. ....* ..... ..... ..... ..| SIGNOFF | |
| #91 |. ....* ....* ..... ..... ..| MBON | |
| ##22 |. ..... ..... ..... ....* ..| DAKY | |
| ##24 |. ..... ..... ..... ....* ..| DSSKY | |
| ##25 |. ..... ..... ..... ....* ..| FWDKY | |
| ##26 |. ..... ..... ..... ....* ..| HTKY | |
| ##27 |. ..... ..... ..... ....* ..| KNOVRKY | |
| ##28 |. ..... ..... ..... ....* ..| MBKY | |
| ##29 |. ..... ..... ..... ....* ..| MSGRKY | |
| ##35 |. ..... ..... ..... ....* ..| TIMEKY | |
| ##36 |. ..... ..... ..... ....* ..| VCKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##37 |. ..... ..... ..... ....* ..| VCRKY | |
| ##38 |. ..... ..... ..... ....* ..| CCKY | |
| ##39 |. ..... ..... ..... ....* ..| CONFKY | |
| ##41 |. ..... ..... ..... ....* ..| NAMEKY | |
| ##42 |. ..... ..... ..... ....* ..| PARKKY | |
| ##43 |. ..... ..... ..... ....* ..| REMKY | |
| ##44 |. ..... ..... ..... ....* ..| STKY | |
| ##45 |. ..... ..... ..... ....* ..| CBKKY | |
| ##46 |. ..... ..... ..... ....* ..| CONSKY | |
| ##47 |. ..... ..... ..... ....* ..| DNDKY | |
| ##48 |. ..... ..... ..... ....* ..| EXHOLDKY | |
| ##49 |. ..... ..... ..... ....* ..| HOLDKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
-----------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##50 |. ..... ..... ..... ....* ..| IUSEKY | |
| ##51 |. ..... ..... ..... ....* ..| LNRKY | |
| ##52 |. ..... ..... ..... ....* ..| PRIVKY | |
| ##53 |. ..... ..... ..... ....* ..| RLSKY | |
| ##54 |. ..... ..... ..... ....* ..| SNRKY | |
| ##55 |. ..... ..... ..... ....* ..| TRNSKY | |
| ##56 |. ..... ..... ..... ....* ..| RCTOFFKY | |
| ##57 |. ..... ..... ..... ....* ..| TOGGLEKY | |
------------------------------------------------------------------------------
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 0 |. ..... *.... ..... ..... ..| ATNDDID | |
| 0 |. ....* ..*** **... ..... ..| ATND | |
| 150 |. .**** ***** **... ..... ..| OWNNODE | |
| 31 |. .**** ***** **... ..... ..| TIE | |
| 37 - 38 |. .**** ***** **... ..... ..| TIE | |
| 40 |. .**** ***** **... ..... ..| TIE | |
| 702 |. .**** ***** **... ..... ..| TIE | |
| 9 |. .**** ..*** **... ..... ..| CO | |
| *0 |. *.... ..*.. ....* ..... ..| ACBK | |
| *10 |. ....* ....* **... ..... ..| CCMANS | R |
| *11 |. ....* ..... ....* ..... ..| AFWDVCE | |
| *12 |. ....* ..... ....* ..... ..| AFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *13 |. ....* ..... ..... ..... ..| AFWDDWD | |
| *14 |. .**** ***** **..* ..... ..| AFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *15 |. *...* ..**. ..... ..... ..| APRIV | |
| *16 |. ....* ..... ..... ..... ..| PUGDIS | |
| *17 |. *.... ..**. ..... ..... .*| SPLIT | |
| *18 |. *.... ..**. ..... ..... ..| TRACE | |
| *19 |. ....* ..... ....* ..... ..| AREM | |
| *20 |. ...** ..... ..... ..... ..| NOPT | |
| *21 |. ....* ..... ....* ..... ..| AFFWDVCE | |
| *22 |. ....* ..... ....* ..... ..| AFFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *23 |. *...* ..**. ..... ..... ..| CALLPARK | |
| *24 |. ....* ..**. ..... ..... ..| DISUON | |
| *3 |. .**** ..**. ..... ..... ..| PUDIR | |
| *40 |. ....* ....* **... ..... ..| CCANS | R |
| *41 |. ..... ..... ..... ..*.. ..| CCDIS | |
| *43 |. .**.* *...* **... ..... ..| DTE | |
| *44 |. .**** ***** **..* ..... ..| FWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *45 |. ..... ..... ..... ..*.. ..| CCMEETME | |
| *46 |. ***** *.*** **... ..... ..| CCSCD | R |
| *47 |. ..... ..... ..... ..*.. ..| CCSURG | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *48 |. ..... ..... ..... ..*.. ..| CCVCE | |
| *49 |. ....* ..... ..... ..... ..| ACOSX | |
| *50 |. ....* ..**. ..... ..... ..| FWDIGNOR | |
| *51 |. ....* ..... ..... ..... ..| ADND | |
| *52 |. ....* ..... ..... ..... ..| AHTVCE | |
| *53 |. ***** *.*** **... ..... ..| CCMSURG | R |
| *54 |. ....* ..... ..... ..... ..| SPD | |
| *55 |. *...* ..**. ..... ..... ..| BABYLSNG | |
| *56 |. ***** *.*** **... ..... ..| CCMS | R |
| *57 |. ..... ..... ..... ..*.. ..| CCS | |
| *58 |. ***** *.*** **... ..... ..| CCSN | R |
| *59 |. ..... ..... ..... ..*.. ..| CCSTN | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *60 |. *.... ..... ..... ..... ..| KNOVR | |
| *61 |. .**** ..*** **... ..... ..| SPDC1 | |
| *62 |. .**** ..*** **... ..... ..| SPDC2 | |
| *63 |. .**.* ..**. ..... ..... ..| SPDI | |
| *64 |. ....* ..... ....* ..... ..| SPDIPROG | |
| *69 |. *.... ..**. ..... ..... ..| EOVR | |
| *7 |. *...* ..**. ..... ..... .*| LNR | |
| *81 |. ....* ..**. ..... .*... ..| APIN1 | |
| *82 |. ....* ..**. ..... .*... ..| APIN2 | |
| *83 |. ....* ..**. ..... .*... ..| APIN3 | |
| *84 |. ....* ..**. ..... .*... ..| APIN4 | |
| *85 |. ....* ..**. ..... .*... ..| APIN5 | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *88 |. ...** ....* *.... ..... ..| CTLS | |
| *89 |. ..*.. *...* *.... ..... ..| TESTLN | |
| *9 |. *.... ..... ..... ..... ..| CONF3 | |
| ** |. ....* ..... ..... ..... ..| PU | |
| *#50 |. *...* ..**. ..... ..... .*| ACDLOGON | |
| *#51 |. *...* ..**. ..... ..... .*| ACDAV | |
| *#52 |. *...* ..**. ..... ..... .*| ACDWORK | |
| *#53 |. *...* ..**. ..... ..... .*| ACC | |
| *#54 |. ....* ..... ..... ..... ..| MONSLNT | |
| *#55 |. ....* ..... ..... ..... ..| MONTONE | |
| *#60 |. *...* ..**. ..... ..... ..| ACDPGS | |
| *#61 |. *...* ..**. ..... ..... ..| ACDPQS | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *#62 |. ....* ..... ..... ..... ..| ACDEMMSG | |
| *#63 |. ....* ..... ..... ..... ..| ACDSHMSG | |
| *#71 |. *...* ..**. ..... ..... ..| CAFAV | |
| *#72 |. *...* ..**. ..... ..... ..| CAFGRAV | |
| *#74 |. *...* ..**. ..... ..... ..| CAFAFWD | |
| #0 |. ....* ..... ..... ..... ..| DCBK | |
| #11 |. ....* ..... ..... ..... ..| DFWDVCE | |
| #12 |. ....* ..... ..... ..... ..| DFWDDTE | |
| #14 |. .**** ***** **..* ..... ..| DFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| #15 |. *...* ..**. ..... ..... ..| DPRIV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #19 |. ....* ..... ..... ..... ..| DREM | |
| #21 |. ....* ..... ..... ..... ..| DFFWDVCE | |
| #22 |. ....* ..... ..... ..... ..| DFFWDDTE | |
| #24 |. ....* ..**. ..... ..... ..| DISUOFF | |
| #49 |. ....* ..... ..... ..... ..| DCOSX | |
| #51 |. ....* ..... ..... ..... ..| DDND | |
| #52 |. ....* ..... ..... ..... ..| DHTVCE | |
| #74 |. ....* ..... ..... ..... ..| DIGIDAT | |
| #8 |. ....* ..**. ..... .*... ..| DPIN | |
| #92 |. ....* ....* ..... ..... ..| MBOFF | |
| #*50 |. *...* ..**. ..... ..... .*| ACDLOGOF | |
| #*51 |. *...* ..**. ..... ..... .*| ACDNAV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #*60 |. *...* ..**. ..... ..... ..| ACDSGS | |
| #*61 |. *...* ..**. ..... ..... ..| ACDSQS | |
| #*70 |. *...* ..**. ..... ..... ..| CAFLOGOF | |
| #*71 |. *...* ..**. ..... ..... ..| CAFNAV | |
| #*72 |. *...* ..**. ..... ..... ..| CAFGRNAV | |
| #*73 |. *...* ..**. ..... ..... ..| CAFGROFF | |
| #*74 |. *...* ..**. ..... ..... ..| CAFDFWD | |
| ##1 |. ..... ..... ....* ..... ..| KYPROG | |
| ##40 |. ..... ..... ..... ....* ..| NAKYLO | |
| ##7 |. ....* ....* ..... ..... ..| MBON | |
| ##8 |. ....* ....* ..... ..... ..| MBOFF | |
------------------------------------------------------------------------------
AMO-WABE -107 DIALLING PLANS, FEATURE ACCESS CODES
DISPLAY COMPLETED;
<dis-ldpln
TYPE = ldp
M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS
LDPNO = 47;
DIS-LDPLN:LDP,47;
H500: AMO LDPLN STARTED
+--------------+------------------------------------------+
| | |
| LDPNO : 47 | LDP : 37-XXXX |
| | SPC : 22 |
+--------------+------+------+------++------+------+------+
| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|
| +------+------+------++------+------+------+
| | 0 | 37 | 1 || 8 | | |
| | 1 | | || 9 | | |
| | 2 | | || 10 | | |
| | 3 | | || 11 | | |
| | 4 | | || 12 | | |
| | 5 | | || 13 | | |
| | 6 | | || 14 | | |
| | 7 | | || 15 | | |
+--------------+------+------+------++------+------+------+
AMO-LDPLN-107 ADMINISTRATION LCR DIALPLAN
DISPLAY COMPLETED;
Step 2. Add the new trunk board using BCSU.
<dis-bcsu
TYPE = tbl
LTG = 1
LTU = 1
SLOT = 73;
DIS-BCSU:TBL,1,1,73;
H500: AMO BCSU STARTED
ADDRESS : LTG 1 LTU 1
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
73 | Q2196-X DIU-N2 1 A | | Q2196-X | 1 | -04 - | READY |
AMO-BCSU -107 BOARD CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Step 3. Configure Class of Trunk using COT.
<dis-cot
COTNO = 4;
DIS-COT:4;
H500: AMO COT STARTED
COT: 4 INFO: 4:Q931 EXTERNAL
DEVICE: INDEP SOURCE: DB
PARAMETER:
PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRI
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
DON'T RELEASE CALL TO BUSY HUNT GROUP BSHT
SEND NO NODE NUMBER TO PARTNER LWNC
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
INCOMING CDR BY ZONE OR FROM LINE ICZL
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
INTERWORKING CALLBACK - NO ANSWER AND MAILBOX CALLBACK IWCB
AOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCC
CONTROLLED TRUNK AND LINE SELECTION CTLS
NO TONE NTON
AMO-COT -107 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;
Step 4. Configure Class of Parameter for device handler using COP.
<dis-cop
COPNO = 4;
DIS-COP:4;
H500: AMO COP STARTED
COP: 4 INFO: 4:Q931
DEVICE: INDEP SOURCE: DB
PARAMETER:
SPECIAL MODE SFRM
REGISTRATION OF LAYER 3 ADVISORIES L3AR
AMO-COP -107 CLASS OF PARAMETER FOR DEVICE HANDLER
DISPLAY COMPLETED;
Step 5. Configure Class of Service using COSSU.
<dis-cossu
TYPE = cos
COS = 32;
DIS-COSSU:COS,32;
H500: AMO COSSU STARTED
+------+----------+---------+---------+---------+----------+
| COS | VOICE | FAX | TTX | VTX | DTE |
+------+----------+---------+---------+---------+----------+
| 32 |>32:TRUNKS |
| | TA | NOCO | NOCO | NOCO | TA |
| | TNOTCR | NOTIE | NOTIE | NOTIE | TNOTCR |
| | | | | | BASIC |
| | | | | | MSN |
| | | | | | CDRINT |
| | | | | | MULTRA |
| | | | | | |
+------+----------+---------+---------+---------+----------+
AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT
DISPLAY COMPLETED;
<dis-cossu
TYPE = lcos
LCOS = 31;
DIS-COSSU:LCOS,31;
H500: AMO COSSU STARTED
THE LCR CLASSMARKS ARE CONTAINED IN THE FOLLOWING LCOS:
+----+-----------------------------------------------------------------+
|LCOS| LCOSV | LCOSD |
| |12345678901234567890123456789012|12345678901234567890123456789012|
| |>SERVICE INFORMATION |
+----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+
| 31| XX| XX|
+----+-----------------------------------------------------------------+
AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT
DISPLAY COMPLETED
Step 6. Add the new trunk group access code using BUEND.
<dis-buend
TGRP = 37
FORMAT = ;
DIS-BUEND:37,;
H500: AMO BUEND STARTED
+------------------------------- FORMAT = L -----------------------------------+
| TGRP NUMBER : 37 TGRP NAME : PRI MAXIMUM NO. : 30 |
| SUBGROUP NO.: 10 DEVICE TYPE : S2CONN TRACENO : 0 |
| RESERVED : N SEARCH MODE : CIRCULAR ACD THRESHOLD : * |
| NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 1 |
| THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 1- 73-0 B-CHL: 1 | 1- 1- 73-0 B-CHL: 2 | 1- 1- 73-0 B-CHL: 3 |
| 1- 1- 73-0 B-CHL: 4 | 1- 1- 73-0 B-CHL: 5 | 1- 1- 73-0 B-CHL: 6 |
| 1- 1- 73-0 B-CHL: 7 | 1- 1- 73-0 B-CHL: 8 | 1- 1- 73-0 B-CHL: 9 |
| 1- 1- 73-0 B-CHL: 10 | 1- 1- 73-0 B-CHL: 11 | 1- 1- 73-0 B-CHL: 12 |
| 1- 1- 73-0 B-CHL: 13 | 1- 1- 73-0 B-CHL: 14 | 1- 1- 73-0 B-CHL: 15 |
| 1- 1- 73-0 B-CHL: 16 | 1- 1- 73-0 B-CHL: 17 | 1- 1- 73-0 B-CHL: 18 |
| 1- 1- 73-0 B-CHL: 19 | 1- 1- 73-0 B-CHL: 20 | 1- 1- 73-0 B-CHL: 21 |
| 1- 1- 73-0 B-CHL: 22 | 1- 1- 73-0 B-CHL: 23 | 1- 1- 73-0 B-CHL: 24 |
| 1- 1- 73-0 B-CHL: 25 | 1- 1- 73-0 B-CHL: 26 | 1- 1- 73-0 B-CHL: 27 |
| 1- 1- 73-0 B-CHL: 28 | 1- 1- 73-0 B-CHL: 29 | 1- 1- 73-0 B-CHL: 30 |
+------------------------------------------------------------------------------+AMO-BUE ND-107 TRUNK GROUP
DISPLAY COMPLETED;
Step 7. Configure trunk using TDCSU.
For Master Side Configuration
<dis-tdcsu
PEN1 = 1-1-73-0;
DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 4 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
AMO-TDCSU-107 DIGITAL TRUNKS
DISPLAY COMPLETED;
<dis-lwpar
INFOPAT = 4
FORMAT = l
DEV = ;
DIS-LWPAR:4,L,;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 4 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = Y DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = Y PERMACT = Y FCBAB = DFH |
| CDG = Y FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 4:COPPER-MASTER CLOCK(DPNSS A-END) |
+-----------------------------------------------------------------------+
AMO-LWPAR-70 LOADWARE PARAMETERS FOR NETWORKING MODULES
DISPLAY COMPLETED;
For Slave Side Configuration
<dis-tdcsu
PEN1 = 1-1-73-0;
DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 1 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
AMO-TDCSU-107 DIGITAL TRUNKS
DISPLAY COMPLETED;
DIS-LWPAR:1,L,;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = N DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = N PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 1:COPPER-DERIVE CLOCK FROM LINE(I421) |
+-----------------------------------------------------------------------+
AMO-LWPAR-104 LOADWARE PARAMETERS FOR NETWORKING MODULES
DISPLAY COMPLETED;
Step 8. Configure Reference Clock using REFTA.
For Master Side Configuration
<dis-refta
TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;
H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 0 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;
For Slave Side Configuration
<dis-refta
TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;
H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 11 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;
Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.
LDAT
<dis-ldat
TYPE = lcr
LROUTE = 37;
DIS-LDAT:LCR,37;
H500: AMO LDAT STARTED
+--------------------------------------------------------------------------+
| LROUTE = 37 LDPLN NAME = PRI TEST SERVICE = ALL |
| TYPE = LCR DNNO OF ROUTE = 1 -1 -999 |
| SERVICE INFO = |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| | | | | | SCHEDULE | CARRIER |BAND| |
| LRTEL | LVAL | TGRP | ODR |LAUTH| ABCDEFGH | ZONE |WDTH| LATTR |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| 1 | 1 | 37 | 1 | 1 | ******** | 1 EMPTY | 1 | NONE |
+-------+-------+-------+-----+-----+----------+------------+----+---------+AMO-LDAT -107 LCR-DIRECTIONS
DISPLAY COMPLETED;
RICHT
<dis-richt
MODE = lrte
LRTE = 37;
DIS-RICHT:LRTE,37;
H500: AMO RICHT STARTED
+---------------------------------------------------------------+
| LRTE = 37 NAME = PRI TEST SRVC = ALL |
| DNNO = 1 -1 -999 |
| ROUTOPT = NO REROUT = YES PLB = NO FWDBL = NO |
| MFV: CNV=FIX DSP=WITHOUT TEXT= PULS=PP300 |
| ROUTENO = 4 BUGS = LIN MAINGROUP = 4 |
| INFO = |
+---------------------------------------------------------------+
| TGRP = 37 LDAT PRI SUBGROUP = 10 |
+---------------------------------------------------------------+AMO-RICHT-107 TRUNK ROUTING
DISPLAY COMPLETED;
Step 10. Configure LCR Out-dial Rules using LODR.
<dis-lodr
ODR = 1
INFOPAT = ;
DIS-LODR:1,;
H500: AMO LODR STARTED
+-------------------------------------------------------+
| ODR POSITION CMD PARAMETER |
+--------+----------------------------------------------+
| 1 | 1 ECHO 2 |
| | 2 END |
+--------+----------------------------------------------+
|INFO:PSTN |
+-------------------------------------------------------+
H03: THE NEXT FREE ODR IS 3AMO-LODR -107 ADMINISTRATION OF LCR OUTDIAL RULES
DISPLAY COMPLETED;
<
Configuring the Cisco CallManager
Figure 1
Configuring the H323 (Cisco 2621) Gateway
Route Pattern Configuration
Test Results
As shown in the diagram below, a Siemens Hicom 330 E PBX was connected via an ISDN E1 PRI link to a Cisco 2621, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 2621 and the PBX.
Test Configuration
Layer 1 (Physical Layer)
The Siemens configuration screen for the E1 trunk interface is reached with the following command:
<cha-tdcsu
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/2621 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 2621 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 2621 Gateway with ISDN protocol type setting of primary-net5 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The "Network/user" or Master/Slave choice for the Siemens Hicom 330 E PBX is made by deactivating the B channels/D-channel (<dea-dssu). A change command is then issued to the Reference clock (<cha-refta) to get to the Master/Slave selection (Pri=0 for Master, 11 for slave). Now the trunk is changed (<cha-tdcsu) to get to Device type prompt (Dev=s2conn), (Bcgrp=1), and loadware parameters (Lwpar=1 for Slave, 4 for Master). The D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
Table 2 Basic Calls: (Enbloc Sending)
Calls Made Call Comp? "Calling Number" Passed to Final Destination? "Calling Name" Passed to Final Destination? "Called Number" Passed to Orig. Side? "Called Name" Passed to Orig. Side? NotesPhone A to Phone C
Yes
Yes
No
No 1
No
Phone C to Phone A
Yes
Yes
No
Yes
No
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
2 The Siemens PRI interface with ETSI setting does not support "Calling Name" presentation Feature.
Test Setup 2
Setup was as follows:
•PBX1 configured as ETSI, emulates User
•Cisco 2621 Gateway configured as PRI EURO, emulates Network
.
Table 6 Switch and Gateway Settings
Siemens Hicom 330 E Switch-type/ Protocol side setting Cisco 6608-E1 ISDN protocol-type/Protocolside settingETSI/Slave
PRI EURO / Network
The test results are the same as in previous section . Refer to Tables 2 through 6 for details.
Appendix A
Call Manager Software Release:
Siemens Hicom 330 E Software release
Software Release
--------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-10-15 11:36:52
-------------------------------------------------------------------------------- <dis-dbc
VERBOSE =
DIS-DBC:;
H500: AMO DBC STARTED
+------------------------------------------------------------------------------+
| SYSTEM CLASSIFICATION : SYSTEM 80 (H80 ) |
| HARDWARE ASSEMBLY : EXTENDED COMPACT CXE (CXE ) |
| DEVELOPMENT LINE : EUROPE DEVELOPMENT (H300) |
| OPERATING MODE : SIMPLEX |
| RESTART TYPE : SYM |
| HW-ARCHITECTURE : 330E |
| HW-ARCHITECTURE TYPE : 4 |
| |
| 'NO OF' HW VALUES |
| LTG'S : 1 LTU'S : 4 LOG.LINES : 8000 MTS BD /GSN: 1 |
| SIUP'S/LTU: 4 TMD24'S PER LTU: 4 PHYS.PORTS: 2688 HWY /MTS BD: 64 |
| HDLC /DCL : 5 PBC /DCL : 1 PBC'S : 17 |
| LOG. SIU LINES : 26 |
| LOG. CONF LINES : 35 |
| LOG. DCL LINES : 36 |
| DB DIMENSIONING-NAME : 350EMSTD CONF-TABLE VERSION: 1 |
| DB SUSY'S: |
| SWITCH NUMBER : L31900Q2999A00001 |
| LOCATION : CUSTOMER |
| BAPPL : 6ECXM48 |
| DBAPPL : 6ECXM48 |
| SYSTEM_ID : PKP091000 |
+------------------------------------------------------------------------------+
AMO-DBC -89 DATABASE CONFIGURATION
DISPLAY COMPLETED;
DIS-VEGAS;
H500: AMO VEGAS STARTED
SYSTEM NO. AMO APS NO. START USER STATUS
SWU: L31900Q2999A00001 REGEN P30252B4200B00103 14.11.00 14:33 DAVE A FINISHED
ADS: L31900Q2999A00001 REGEN P30252B4200A00103 14.11.00 14:35 DAVE A FINISHED
AMO-VEGAS-107 ADMIN. OF DATABASE GENERATION RUNS ON SUPPORT SYSTEM
DISPLAY COMPLETED;
<
Cisco 2621 Router Configuration
2621_B#sh version
Cisco Internetwork Operating System Software
IOS (tm) C2600 Software (C2600-JS-M), Version 12.2(3.5)T, MAINTENANCE INTERIM S
OFTWARE
TAC Support: http://www.cisco.com/tac
Copyright (c) 1986-2001 by cisco Systems, Inc.
Compiled Fri 03-Aug-01 22:45 by ccai
Image text-base: 0x80008088, data-base: 0x81631DD8
ROM: System Bootstrap, Version 12.1(3r)T2, RELEASE SOFTWARE (fc1)
2621_B uptime is 16 hours, 6 minutes
System returned to ROM by power-on
System image file is "flash:c2600-js-mz.122-3.5.T"
cisco 2621 (MPC860) processor (revision 0x200) with 56320K/9216K bytes of memory
.
Processor board ID JAD051516TX (503811939)
M860 processor: part number 0, mask 49
Channelized E1, Version 1.0.
Bridging software.
X.25 software, Version 3.0.0.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
TN3270 Emulation software.
Primary Rate ISDN software, Version 1.1.
2 FastEthernet/IEEE 802.3 interface(s)
31 Serial network interface(s)
2 Channelized E1/PRI port(s)
32K bytes of non-volatile configuration memory.
16384K bytes of processor board System flash (Read/Write)
Configuration register is 0x2102
2621_B#
_______________________________________________________________________________________ __
2621_B#sh diag
Slot 0:
C2621 2FE Mainboard Port adapter, 2 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 2.0
PCB Serial Number : JAD051516TX (503811939)
Part Number : 73-3200-08
RMA History : 00
RMA Number : 0-0-0-0
Board Revision : A0
Deviation Number : 0-21249
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 A2 41 02 00 C1 17 4A 41 44 30 35 31
0x10: 35 31 36 54 58 20 28 35 30 33 38 31 31 39 33 39
0x20: 29 82 49 0C 80 08 04 00 81 00 00 00 00 42 41 30
0x30: 80 00 00 53 01 FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Slot 1:
High Density Voice Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 1.1
Top Assy. Part Number : 800-03567-01
Board Revision : F1
Deviation Number : 0-0
Fab Version : 02
PCB Serial Number : JAB05080LU9
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 01
0x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 30
0x20: 35 30 38 30 4C 55 39 03 00 81 00 00 00 00 04 00
0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
VIC Slot 0:
E1 (2 Port) Multi-Flex Trunk WAN Daughter Card
Hardware revision 1.0 Board revision B0
Serial number 18801733 Part number 800-04479-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 23 01 00 01 1E E4 45 50 11 7F 01 00 00 00 00
0x30: 58 00 00 00 00 03 09 00 FF FF FF FF FF FF FF FF
HDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyala
HDV memory size 524280 heap free 175065
2621_B#
_______________________________________________________________________________________ __
2621_B#sh controllers e1 1/0
E1 1/0 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
alarm-trigger is not set
Version info Firmware: 20010710, FPGA: 15
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (71 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
2621_B#
_______________________________________________________________________________________ __
2621_B#sh configuration
Using 1813 out of 29688 bytes
!
version 12.2
no parser cache
service timestamps debug datetime msec localtime show-timezone
service timestamps log uptime
no service password-encryption
!
hostname 2621_B
!
no logging buffered
enable password cisco
!
!
!
memory-size iomem 15
voice-card 1
dspfarm
!
ip subnet-zero
!
!
no ip domain-lookup
!
isdn switch-type primary-net5
!
!
voice class codec 1
codec preference 1 g729r8
codec preference 2 g711ulaw
codec preference 3 g711alaw
!
!
!
!
!
!
!
controller E1 1/0
pri-group timeslots 1-31
!
controller E1 1/1
!
!
!
!
interface FastEthernet0/0
ip address 192.168.100.2 255.255.255.0
no ip mroute-cache
load-interval 30
no keepalive
speed auto
half-duplex
!
interface FastEthernet0/1
ip address 10.1.1.129 255.255.255.0
no ip mroute-cache
duplex auto
speed auto
!
interface Serial1/0:15
no ip address
no logging event link-status
isdn switch-type primary-net5
isdn incoming-voice voice
isdn T321 40000
isdn T203 30000
isdn T306 60000
isdn T310 30000
isdn bchan-number-order ascending
no cdp enable
!
router rip
network 1.0.0.0
network 192.168.100.0
!
ip classless
no ip http server
ip pim bidir-enable
!
dialer-list 1 protocol ip permit
dialer-list 1 protocol ipx permit
!
!
snmp-server packetsize 4096
snmp-server manager
tftp-server nvram
call rsvp-sync
!
voice-port 1/0:15
!
!
mgcp profile default
!
dial-peer cor custom
!
!
!
dial-peer voice 1 pots
destination-pattern 5...
direct-inward-dial
port 1/0:15
prefix 5
!
dial-peer voice 3 voip
destination-pattern 2...
progress_ind setup enable 1
voice-class codec 1
session target ipv4:10.1.1.2
dtmf-relay h245-alphanumeric
!
!
line con 0
exec-timeout 0 0
line aux 0
exec-timeout 0 0
line vty 0 4
exec-timeout 0 0
password cisco
login
line vty 5 15
exec-timeout 0 0
login
!
scheduler allocate 3996 1000
!
end
2621_B#
Posted: Thu Sep 6 13:17:09 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.