Table Of Contents
Cisco Systems Hardware and Software Requirements
PBX Hardware and Software Requirements
Calling Name and Number feature
Configuring the Siemens Hicom 330 E PBX
Siemens Hicom 330 E PBX Configuration Menus and Commands
Configuring the Cisco CallManager
Siemens Hicom 330 E Software release
Cisco 2621 Router Configuration
Application Note
Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 2621-E1 PRI-NET5 Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager using Cisco 2621-E1 PRI-NET5 Gateway.
Integration Description
Connectivity is achieved by using the ETSI standard PRI protocol. The Siemens Hicom 330 E can be configured as either NETWORK or USER side.
Cisco Systems Hardware and Software Requirements
•
Hardware (Cisco 2621 Gateway): 2MFT E1 Port
•
Software: CallManager Release 3.1
PBX Hardware and Software Requirements
•
Hardware: DIU-N2
•
Software: Version 3.1
Features Supported
Key Features Supported
Calling/Called Number
Key Features Not Supported
Calling/Called Name
Limitations
Calling Name and Number feature
•
Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E PBX.
•
When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called Number is displayed on both phones after the call is answered as expected.
•
When calling from Siemens digital phone to Cisco 7960 IP phone, the IP phone displays Connected Number after the call is answered. The Siemens phone however does NOT get updated when the call is answered. It displays the numbers being dialed instead. (i.e. Access Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.
Network Topology
Figure 1 Basic Setup
Configuration
Configuring the Siemens Hicom 330 E PBX
Use the following steps to configure the Siemens Hicom 330 E PBX.
Step 1.
Add the new access code to Dialing Plans using WABE + LDPLN.
Step 2.
Add the new trunk board using BCSU.
Step 3.
Configure Class of Trunk using COT.
Step 4.
Configure Class of Parameter for device handler using COP.
Step 5.
Configure Class of Service using COSSU.
Step 6.
Add the new trunk group access code using BUEND.
Step 7.
Configure trunk using TDCSU.
Step 8.
Configure Reference Clock using REFTA.
Step 9.
Configure trunk Least Cost Routing using LDAT + RICHT.
Step 10.
Configure LCR Out-dial Rules using LODR.
Siemens Hicom 330 E PBX Configuration Menus and Commands
Step 1.
Add the new access code to Dialing Plans using WABE + LDPLN.
<dis-wabeTYPE = genCD =DPLN = 0;DIS-WABE:GEN,,0;H500: AMO WABE STARTED------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 001 - 002 |* ..... ..... ..... ..... ..| NETRTE | || 11 |. ..... ..... ..... ....* ..| MBKY | || 3001 |. .**** ***** **... ..... ..| STN | R || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 3007 |. ..... ..... ..... ....* ..| MBKY | || 3007 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 4100 - 4500 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 72 || | | |DNNO 1- 1-702 |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 5000 - 5007 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 5008 - 5009 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 99 || | | |DNNO 1- 1- 99 || 5010 |. .**** *.*** **... ..... ..| ATNDIND | || 800 |. ..... *...* **... ..... ..| ATNDDID | || 854 |. .**** ***** **... ..... ..| NETW | R || | | |DESTNO 2 || | | |DNNO 0- 0- 0 || *66 |. ....* ..... ..... ..... ..| SIGNON | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *91 |. ....* ....* ..... ..... ..| MBOFF | || #66 |. ....* ..... ..... ..... ..| SIGNOFF | || #91 |. ....* ....* ..... ..... ..| MBON | || ##22 |. ..... ..... ..... ....* ..| DAKY | || ##24 |. ..... ..... ..... ....* ..| DSSKY | || ##25 |. ..... ..... ..... ....* ..| FWDKY | || ##26 |. ..... ..... ..... ....* ..| HTKY | || ##27 |. ..... ..... ..... ....* ..| KNOVRKY | || ##28 |. ..... ..... ..... ....* ..| MBKY | || ##29 |. ..... ..... ..... ....* ..| MSGRKY | || ##35 |. ..... ..... ..... ....* ..| TIMEKY | || ##36 |. ..... ..... ..... ....* ..| VCKY | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| ##37 |. ..... ..... ..... ....* ..| VCRKY | || ##38 |. ..... ..... ..... ....* ..| CCKY | || ##39 |. ..... ..... ..... ....* ..| CONFKY | || ##41 |. ..... ..... ..... ....* ..| NAMEKY | || ##42 |. ..... ..... ..... ....* ..| PARKKY | || ##43 |. ..... ..... ..... ....* ..| REMKY | || ##44 |. ..... ..... ..... ....* ..| STKY | || ##45 |. ..... ..... ..... ....* ..| CBKKY | || ##46 |. ..... ..... ..... ....* ..| CONSKY | || ##47 |. ..... ..... ..... ....* ..| DNDKY | || ##48 |. ..... ..... ..... ....* ..| EXHOLDKY | || ##49 |. ..... ..... ..... ....* ..| HOLDKY | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |-----------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| ##50 |. ..... ..... ..... ....* ..| IUSEKY | || ##51 |. ..... ..... ..... ....* ..| LNRKY | || ##52 |. ..... ..... ..... ....* ..| PRIVKY | || ##53 |. ..... ..... ..... ....* ..| RLSKY | || ##54 |. ..... ..... ..... ....* ..| SNRKY | || ##55 |. ..... ..... ..... ....* ..| TRNSKY | || ##56 |. ..... ..... ..... ....* ..| RCTOFFKY | || ##57 |. ..... ..... ..... ....* ..| TOGGLEKY | |------------------------------------------------------------------------------------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 0 |. ..... *.... ..... ..... ..| ATNDDID | || 0 |. ....* ..*** **... ..... ..| ATND | || 150 |. .**** ***** **... ..... ..| OWNNODE | || 31 |. .**** ***** **... ..... ..| TIE | || 37 - 38 |. .**** ***** **... ..... ..| TIE | || 40 |. .**** ***** **... ..... ..| TIE | || 702 |. .**** ***** **... ..... ..| TIE | || 9 |. .**** ..*** **... ..... ..| CO | || *0 |. *.... ..*.. ....* ..... ..| ACBK | || *10 |. ....* ....* **... ..... ..| CCMANS | R || *11 |. ....* ..... ....* ..... ..| AFWDVCE | || *12 |. ....* ..... ....* ..... ..| AFWDDTE | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *13 |. ....* ..... ..... ..... ..| AFWDDWD | || *14 |. .**** ***** **..* ..... ..| AFWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || *15 |. *...* ..**. ..... ..... ..| APRIV | || *16 |. ....* ..... ..... ..... ..| PUGDIS | || *17 |. *.... ..**. ..... ..... .*| SPLIT | || *18 |. *.... ..**. ..... ..... ..| TRACE | || *19 |. ....* ..... ....* ..... ..| AREM | || *20 |. ...** ..... ..... ..... ..| NOPT | || *21 |. ....* ..... ....* ..... ..| AFFWDVCE | || *22 |. ....* ..... ....* ..... ..| AFFWDDTE | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *23 |. *...* ..**. ..... ..... ..| CALLPARK | || *24 |. ....* ..**. ..... ..... ..| DISUON | || *3 |. .**** ..**. ..... ..... ..| PUDIR | || *40 |. ....* ....* **... ..... ..| CCANS | R || *41 |. ..... ..... ..... ..*.. ..| CCDIS | || *43 |. .**.* *...* **... ..... ..| DTE | || *44 |. .**** ***** **..* ..... ..| FWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || *45 |. ..... ..... ..... ..*.. ..| CCMEETME | || *46 |. ***** *.*** **... ..... ..| CCSCD | R || *47 |. ..... ..... ..... ..*.. ..| CCSURG | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *48 |. ..... ..... ..... ..*.. ..| CCVCE | || *49 |. ....* ..... ..... ..... ..| ACOSX | || *50 |. ....* ..**. ..... ..... ..| FWDIGNOR | || *51 |. ....* ..... ..... ..... ..| ADND | || *52 |. ....* ..... ..... ..... ..| AHTVCE | || *53 |. ***** *.*** **... ..... ..| CCMSURG | R || *54 |. ....* ..... ..... ..... ..| SPD | || *55 |. *...* ..**. ..... ..... ..| BABYLSNG | || *56 |. ***** *.*** **... ..... ..| CCMS | R || *57 |. ..... ..... ..... ..*.. ..| CCS | || *58 |. ***** *.*** **... ..... ..| CCSN | R || *59 |. ..... ..... ..... ..*.. ..| CCSTN | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *60 |. *.... ..... ..... ..... ..| KNOVR | || *61 |. .**** ..*** **... ..... ..| SPDC1 | || *62 |. .**** ..*** **... ..... ..| SPDC2 | || *63 |. .**.* ..**. ..... ..... ..| SPDI | || *64 |. ....* ..... ....* ..... ..| SPDIPROG | || *69 |. *.... ..**. ..... ..... ..| EOVR | || *7 |. *...* ..**. ..... ..... .*| LNR | || *81 |. ....* ..**. ..... .*... ..| APIN1 | || *82 |. ....* ..**. ..... .*... ..| APIN2 | || *83 |. ....* ..**. ..... .*... ..| APIN3 | || *84 |. ....* ..**. ..... .*... ..| APIN4 | || *85 |. ....* ..**. ..... .*... ..| APIN5 | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *88 |. ...** ....* *.... ..... ..| CTLS | || *89 |. ..*.. *...* *.... ..... ..| TESTLN | || *9 |. *.... ..... ..... ..... ..| CONF3 | || ** |. ....* ..... ..... ..... ..| PU | || *#50 |. *...* ..**. ..... ..... .*| ACDLOGON | || *#51 |. *...* ..**. ..... ..... .*| ACDAV | || *#52 |. *...* ..**. ..... ..... .*| ACDWORK | || *#53 |. *...* ..**. ..... ..... .*| ACC | || *#54 |. ....* ..... ..... ..... ..| MONSLNT | || *#55 |. ....* ..... ..... ..... ..| MONTONE | || *#60 |. *...* ..**. ..... ..... ..| ACDPGS | || *#61 |. *...* ..**. ..... ..... ..| ACDPQS | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *#62 |. ....* ..... ..... ..... ..| ACDEMMSG | || *#63 |. ....* ..... ..... ..... ..| ACDSHMSG | || *#71 |. *...* ..**. ..... ..... ..| CAFAV | || *#72 |. *...* ..**. ..... ..... ..| CAFGRAV | || *#74 |. *...* ..**. ..... ..... ..| CAFAFWD | || #0 |. ....* ..... ..... ..... ..| DCBK | || #11 |. ....* ..... ..... ..... ..| DFWDVCE | || #12 |. ....* ..... ..... ..... ..| DFWDDTE | || #14 |. .**** ***** **..* ..... ..| DFWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || #15 |. *...* ..**. ..... ..... ..| DPRIV | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| #19 |. ....* ..... ..... ..... ..| DREM | || #21 |. ....* ..... ..... ..... ..| DFFWDVCE | || #22 |. ....* ..... ..... ..... ..| DFFWDDTE | || #24 |. ....* ..**. ..... ..... ..| DISUOFF | || #49 |. ....* ..... ..... ..... ..| DCOSX | || #51 |. ....* ..... ..... ..... ..| DDND | || #52 |. ....* ..... ..... ..... ..| DHTVCE | || #74 |. ....* ..... ..... ..... ..| DIGIDAT | || #8 |. ....* ..**. ..... .*... ..| DPIN | || #92 |. ....* ....* ..... ..... ..| MBOFF | || #*50 |. *...* ..**. ..... ..... .*| ACDLOGOF | || #*51 |. *...* ..**. ..... ..... .*| ACDNAV | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| #*60 |. *...* ..**. ..... ..... ..| ACDSGS | || #*61 |. *...* ..**. ..... ..... ..| ACDSQS | || #*70 |. *...* ..**. ..... ..... ..| CAFLOGOF | || #*71 |. *...* ..**. ..... ..... ..| CAFNAV | || #*72 |. *...* ..**. ..... ..... ..| CAFGRNAV | || #*73 |. *...* ..**. ..... ..... ..| CAFGROFF | || #*74 |. *...* ..**. ..... ..... ..| CAFDFWD | || ##1 |. ..... ..... ....* ..... ..| KYPROG | || ##40 |. ..... ..... ..... ....* ..| NAKYLO | || ##7 |. ....* ....* ..... ..... ..| MBON | || ##8 |. ....* ....* ..... ..... ..| MBOFF | |------------------------------------------------------------------------------AMO-WABE -107 DIALLING PLANS, FEATURE ACCESS CODESDISPLAY COMPLETED;<dis-ldplnTYPE = ldpM40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERSLDPNO = 47;DIS-LDPLN:LDP,47;H500: AMO LDPLN STARTED+--------------+------------------------------------------+| | || LDPNO : 47 | LDP : 37-XXXX || | SPC : 22 |+--------------+------+------+------++------+------+------+| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|| +------+------+------++------+------+------+| | 0 | 37 | 1 || 8 | | || | 1 | | || 9 | | || | 2 | | || 10 | | || | 3 | | || 11 | | || | 4 | | || 12 | | || | 5 | | || 13 | | || | 6 | | || 14 | | || | 7 | | || 15 | | |+--------------+------+------+------++------+------+------+AMO-LDPLN-107 ADMINISTRATION LCR DIALPLANDISPLAY COMPLETED;Step 2.
Add the new trunk board using BCSU.
<dis-bcsuTYPE = tblLTG = 1LTU = 1SLOT = 73;DIS-BCSU:TBL,1,1,73;H500: AMO BCSU STARTEDADDRESS : LTG 1 LTU 1-----+-----------+---------+---+---+-+------------+-----+--------+------------+| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |-----+-----------+---------+---+---+-+------------+-----+--------+------------+73 | Q2196-X DIU-N2 1 A | | Q2196-X | 1 | -04 - | READY |AMO-BCSU -107 BOARD CONFIGURATION, SWITCHING UNITDISPLAY COMPLETED;Step 3.
Configure Class of Trunk using COT.
<dis-cotCOTNO = 4;DIS-COT:4;H500: AMO COT STARTEDCOT: 4 INFO: 4:Q931 EXTERNALDEVICE: INDEP SOURCE: DBPARAMETER:PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRIRECALL IF USER HANGS UP IN CONSULTATION CALL RCLTRUNK CALL TRANSFER XFERTRUNK SIGNALING ANSWER ANSCHANGEOVER FROM HOLD TO RING TONE CHRTKNOCKING OVERRIDE POSSIBLE KNORCALL EXTEND FOR BUSY, RING OR CALL STATE CEBCNETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBNNETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFNDON'T RELEASE CALL TO BUSY HUNT GROUP BSHTSEND NO NODE NUMBER TO PARTNER LWNCINCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCRTSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCSINCOMING CDR BY ZONE OR FROM LINE ICZLINCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRDINTERWORKING CALLBACK - NO ANSWER AND MAILBOX CALLBACK IWCBAOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCCCONTROLLED TRUNK AND LINE SELECTION CTLSNO TONE NTONAMO-COT -107 CLASS OF TRUNK FOR CALL PROCESSINGDISPLAY COMPLETED;Step 4.
Configure Class of Parameter for device handler using COP.
<dis-copCOPNO = 4;DIS-COP:4;H500: AMO COP STARTEDCOP: 4 INFO: 4:Q931DEVICE: INDEP SOURCE: DBPARAMETER:SPECIAL MODE SFRMREGISTRATION OF LAYER 3 ADVISORIES L3ARAMO-COP -107 CLASS OF PARAMETER FOR DEVICE HANDLERDISPLAY COMPLETED;Step 5.
Configure Class of Service using COSSU.
<dis-cossuTYPE = cosCOS = 32;DIS-COSSU:COS,32;H500: AMO COSSU STARTED+------+----------+---------+---------+---------+----------+| COS | VOICE | FAX | TTX | VTX | DTE |+------+----------+---------+---------+---------+----------+| 32 |>32:TRUNKS || | TA | NOCO | NOCO | NOCO | TA || | TNOTCR | NOTIE | NOTIE | NOTIE | TNOTCR || | | | | | BASIC || | | | | | MSN || | | | | | CDRINT || | | | | | MULTRA || | | | | | |+------+----------+---------+---------+---------+----------+AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNITDISPLAY COMPLETED;<dis-cossuTYPE = lcosLCOS = 31;DIS-COSSU:LCOS,31;H500: AMO COSSU STARTEDTHE LCR CLASSMARKS ARE CONTAINED IN THE FOLLOWING LCOS:+----+-----------------------------------------------------------------+|LCOS| LCOSV | LCOSD || |12345678901234567890123456789012|12345678901234567890123456789012|| |>SERVICE INFORMATION |+----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+| 31| XX| XX|+----+-----------------------------------------------------------------+AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNITDISPLAY COMPLETEDStep 6.
Add the new trunk group access code using BUEND.
<dis-buendTGRP = 37FORMAT = ;DIS-BUEND:37,;H500: AMO BUEND STARTED+------------------------------- FORMAT = L -----------------------------------+| TGRP NUMBER : 37 TGRP NAME : PRI MAXIMUM NO. : 30 || SUBGROUP NO.: 10 DEVICE TYPE : S2CONN TRACENO : 0 || RESERVED : N SEARCH MODE : CIRCULAR ACD THRESHOLD : * || NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 1 || THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |+------------------------------------------------------------------------------+| 1- 1- 73-0 B-CHL: 1 | 1- 1- 73-0 B-CHL: 2 | 1- 1- 73-0 B-CHL: 3 || 1- 1- 73-0 B-CHL: 4 | 1- 1- 73-0 B-CHL: 5 | 1- 1- 73-0 B-CHL: 6 || 1- 1- 73-0 B-CHL: 7 | 1- 1- 73-0 B-CHL: 8 | 1- 1- 73-0 B-CHL: 9 || 1- 1- 73-0 B-CHL: 10 | 1- 1- 73-0 B-CHL: 11 | 1- 1- 73-0 B-CHL: 12 || 1- 1- 73-0 B-CHL: 13 | 1- 1- 73-0 B-CHL: 14 | 1- 1- 73-0 B-CHL: 15 || 1- 1- 73-0 B-CHL: 16 | 1- 1- 73-0 B-CHL: 17 | 1- 1- 73-0 B-CHL: 18 || 1- 1- 73-0 B-CHL: 19 | 1- 1- 73-0 B-CHL: 20 | 1- 1- 73-0 B-CHL: 21 || 1- 1- 73-0 B-CHL: 22 | 1- 1- 73-0 B-CHL: 23 | 1- 1- 73-0 B-CHL: 24 || 1- 1- 73-0 B-CHL: 25 | 1- 1- 73-0 B-CHL: 26 | 1- 1- 73-0 B-CHL: 27 || 1- 1- 73-0 B-CHL: 28 | 1- 1- 73-0 B-CHL: 29 | 1- 1- 73-0 B-CHL: 30 |+------------------------------------------------------------------------------+AMO-BUE ND-107 TRUNK GROUPDISPLAY COMPLETED;Step 7.
Configure trunk using TDCSU.
For Master Side Configuration<dis-tdcsuPEN1 = 1-1-73-0;DIS-TDCSU:1-1-73-0;H500: AMO TDCSU STARTED+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+| DEV = S2CONN PEN = 1-01-073-0 ||---------------------------------------------------------------------------|| COTNO = 4 COPNO = 4 DPLN = 0 || ITR = 0 COS = 32 LCOSV = 31 || LCOSD = 31 CCT = PRI DESTNO = 99 || PROTVAR = ETSI SEGMENT = 1 TCHARG = N || SUPPRESS = 0 DGTPR = CHIMAP = N || ISDNCC = ISDNAC = ISDNLC = || ISDNIP = ISDNNP = || PNPL2C = PNPL1C = PNPLC = || PNPL2P = PNPL1P = PNPAC = || TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 || ALARMNO = 2 FIDX = 1 CARRIER = 1 || ZONE = EMPTY COTX = 4 FWDX = 10 || DOMTYPE = DOMAINNO = TPROFNO = || INIGHT = || CCHDL = UUSCCX = 16 UUSCCY = 8 ||---------------------------------------------------------------------------|| TGRP = 37 SRCHMODE = CIR BCNEG = N || BCGR = 1 INS = Y LWPAR = 4 || LWPP = 0 LWLT = 0 LWPS = 0 || LWR1 = 0 LWR2 = 0 || BCHAN 1 && 30 || |+---------------------------------------------------------------------------+AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKSDISPLAY COMPLETED;<dis-lwparINFOPAT = 4FORMAT = lDEV = ;DIS-LWPAR:4,L,;H500: AMO LWPAR STARTED+-----------------------------------------------------------------------+| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 4 |+-----------------------------------------------------------------------+| LNTYPE = COPPER VERSION = S2 QUAL = ON || MASTER = Y DCHAN1 = 16 DCHAN2 = 0 || PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. || SMD = Y PERMACT = Y FCBAB = DFH || CDG = Y FIXEDTEI = 0 CNTRNR = 255 || TEIVERIF = N CRC4REP = N || DEV = INDEP || INFO = 4:COPPER-MASTER CLOCK(DPNSS A-END) |+-----------------------------------------------------------------------+AMO-LWPAR-70 LOADWARE PARAMETERS FOR NETWORKING MODULESDISPLAY COMPLETED;For Slave Side Configuration<dis-tdcsuPEN1 = 1-1-73-0;DIS-TDCSU:1-1-73-0;H500: AMO TDCSU STARTED+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+| DEV = S2CONN PEN = 1-01-073-0 ||---------------------------------------------------------------------------|| COTNO = 4 COPNO = 4 DPLN = 0 || ITR = 0 COS = 32 LCOSV = 31 || LCOSD = 31 CCT = PRI DESTNO = 99 || PROTVAR = ETSI SEGMENT = 1 TCHARG = N || SUPPRESS = 0 DGTPR = CHIMAP = N || ISDNCC = ISDNAC = ISDNLC = || ISDNIP = ISDNNP = || PNPL2C = PNPL1C = PNPLC = || PNPL2P = PNPL1P = PNPAC = || TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 || ALARMNO = 2 FIDX = 1 CARRIER = 1 || ZONE = EMPTY COTX = 4 FWDX = 10 || DOMTYPE = DOMAINNO = TPROFNO = || INIGHT = || CCHDL = UUSCCX = 16 UUSCCY = 8 ||---------------------------------------------------------------------------|| TGRP = 37 SRCHMODE = CIR BCNEG = N || BCGR = 1 INS = Y LWPAR = 1 || LWPP = 0 LWLT = 0 LWPS = 0 || LWR1 = 0 LWR2 = 0 || BCHAN 1 && 30 || |+---------------------------------------------------------------------------+AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKSDISPLAY COMPLETED;DIS-LWPAR:1,L,;H500: AMO LWPAR STARTED+-----------------------------------------------------------------------+| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |+-----------------------------------------------------------------------+| LNTYPE = COPPER VERSION = S2 QUAL = ON || MASTER = N DCHAN1 = 16 DCHAN2 = 0 || PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. || SMD = N PERMACT = Y FCBAB = DFH || CDG = N FIXEDTEI = 0 CNTRNR = 255 || TEIVERIF = N CRC4REP = N || DEV = INDEP || INFO = 1:COPPER-DERIVE CLOCK FROM LINE(I421) |+-----------------------------------------------------------------------+AMO-LWPAR-104 LOADWARE PARAMETERS FOR NETWORKING MODULESDISPLAY COMPLETED;Step 8.
Configure Reference Clock using REFTA.
For Master Side Configuration<dis-reftaTYPE = circuitPEN = 1-1-73-0;DIS-REFTA:CIRCUIT,1-1-73-0;H500: AMO REFTA STARTED+-------------------------------------------------------------------------+| R E F E R E N C E C L O C K C I R C U I T S |+--------------+---------+----------+------+--------+------+--------+-----+| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|| | | | | | | |BUT || | | | | | | |ASYN.|+--------------+---------+----------+------+--------+------+--------+-----+| 1- 1- 73- 0 | DIU-N2 | S2CONN | 0 | 15485 | N | X | N |+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLEDISPLAY COMPLETED;For Slave Side Configuration<dis-reftaTYPE = circuitPEN = 1-1-73-0;DIS-REFTA:CIRCUIT,1-1-73-0;H500: AMO REFTA STARTED+-------------------------------------------------------------------------+| R E F E R E N C E C L O C K C I R C U I T S |+--------------+---------+----------+------+--------+------+--------+-----+| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|| | | | | | | |BUT || | | | | | | |ASYN.|+--------------+---------+----------+------+--------+------+--------+-----+| 1- 1- 73- 0 | DIU-N2 | S2CONN | 11 | 15485 | N | X | N |+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLEDISPLAY COMPLETED;Step 9.
Configure trunk Least Cost Routing using LDAT + RICHT.
LDAT<dis-ldatTYPE = lcrLROUTE = 37;DIS-LDAT:LCR,37;H500: AMO LDAT STARTED+--------------------------------------------------------------------------+| LROUTE = 37 LDPLN NAME = PRI TEST SERVICE = ALL || TYPE = LCR DNNO OF ROUTE = 1 -1 -999 || SERVICE INFO = |+-------+-------+-------+-----+-----+----------+------------+----+---------+| | | | | | SCHEDULE | CARRIER |BAND| || LRTEL | LVAL | TGRP | ODR |LAUTH| ABCDEFGH | ZONE |WDTH| LATTR |+-------+-------+-------+-----+-----+----------+------------+----+---------+| 1 | 1 | 37 | 1 | 1 | ******** | 1 EMPTY | 1 | NONE |+-------+-------+-------+-----+-----+----------+------------+----+---------+AMO-LDAT -107 LCR-DIRECTIONSDISPLAY COMPLETED;RICHT<dis-richtMODE = lrteLRTE = 37;DIS-RICHT:LRTE,37;H500: AMO RICHT STARTED+---------------------------------------------------------------+| LRTE = 37 NAME = PRI TEST SRVC = ALL || DNNO = 1 -1 -999 || ROUTOPT = NO REROUT = YES PLB = NO FWDBL = NO || MFV: CNV=FIX DSP=WITHOUT TEXT= PULS=PP300 || ROUTENO = 4 BUGS = LIN MAINGROUP = 4 || INFO = |+---------------------------------------------------------------+| TGRP = 37 LDAT PRI SUBGROUP = 10 |+---------------------------------------------------------------+AMO-RICHT-107 TRUNK ROUTINGDISPLAY COMPLETED;Step 10.
Configure LCR Out-dial Rules using LODR.
<dis-lodrODR = 1INFOPAT = ;DIS-LODR:1,;H500: AMO LODR STARTED+-------------------------------------------------------+| ODR POSITION CMD PARAMETER |+--------+----------------------------------------------+| 1 | 1 ECHO 2 || | 2 END |+--------+----------------------------------------------+|INFO:PSTN |+-------------------------------------------------------+H03: THE NEXT FREE ODR IS 3AMO-LODR -107 ADMINISTRATION OF LCR OUTDIAL RULESDISPLAY COMPLETED;<Configuring the Cisco CallManager
Figure 1
Configuring the H323 (Cisco 2621) Gateway
Route Pattern Configuration
Test Results
As shown in the diagram below, a Siemens Hicom 330 E PBX was connected via an ISDN E1 PRI link to a Cisco 2621, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 2621 and the PBX.
Test Configuration
Layer 1 (Physical Layer)
The Siemens configuration screen for the E1 trunk interface is reached with the following command:
<cha-tdcsuLayers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/2621 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 2621 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 2621 Gateway with ISDN protocol type setting of primary-net5 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The "Network/user" or Master/Slave choice for the Siemens Hicom 330 E PBX is made by deactivating the B channels/D-channel (<dea-dssu). A change command is then issued to the Reference clock (<cha-refta) to get to the Master/Slave selection (Pri=0 for Master, 11 for slave). Now the trunk is changed (<cha-tdcsu) to get to Device type prompt (Dev=s2conn), (Bcgrp=1), and loadware parameters (Lwpar=1 for Slave, 4 for Master). The D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
Table 2 Basic Calls: (Enbloc Sending)
Calls Made Call Comp? "Calling Number" Passed to Final Destination? "Calling Name" Passed to Final Destination? "Called Number" Passed to Orig. Side? "Called Name" Passed to Orig. Side? NotesPhone A to Phone C
Yes
Yes
No
No 1
No
Phone C to Phone A
Yes
Yes
No
Yes
No
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
2 The Siemens PRI interface with ETSI setting does not support "Calling Name" presentation Feature.
Test Setup 2
Setup was as follows:
•
PBX1 configured as ETSI, emulates User
•
Cisco 2621 Gateway configured as PRI EURO, emulates Network
.
Table 6 Switch and Gateway Settings
Siemens Hicom 330 E Switch-type/ Protocol side setting Cisco 6608-E1 ISDN protocol-type/Protocolside settingETSI/Slave
PRI EURO / Network
The test results are the same as in previous section . Refer to Tables 2 through 6 for details.
Appendix A
Call Manager Software Release:
Siemens Hicom 330 E Software release
Software Release--------------------------------------------------------------------------------TERMINAL 1 L O G O N 01-10-15 11:36:52-------------------------------------------------------------------------------- <dis-dbcVERBOSE =DIS-DBC:;H500: AMO DBC STARTED+------------------------------------------------------------------------------+| SYSTEM CLASSIFICATION : SYSTEM 80 (H80 ) || HARDWARE ASSEMBLY : EXTENDED COMPACT CXE (CXE ) || DEVELOPMENT LINE : EUROPE DEVELOPMENT (H300) || OPERATING MODE : SIMPLEX || RESTART TYPE : SYM || HW-ARCHITECTURE : 330E || HW-ARCHITECTURE TYPE : 4 || || 'NO OF' HW VALUES || LTG'S : 1 LTU'S : 4 LOG.LINES : 8000 MTS BD /GSN: 1 || SIUP'S/LTU: 4 TMD24'S PER LTU: 4 PHYS.PORTS: 2688 HWY /MTS BD: 64 || HDLC /DCL : 5 PBC /DCL : 1 PBC'S : 17 || LOG. SIU LINES : 26 || LOG. CONF LINES : 35 || LOG. DCL LINES : 36 || DB DIMENSIONING-NAME : 350EMSTD CONF-TABLE VERSION: 1 || DB SUSY'S: || SWITCH NUMBER : L31900Q2999A00001 || LOCATION : CUSTOMER || BAPPL : 6ECXM48 || DBAPPL : 6ECXM48 || SYSTEM_ID : PKP091000 |+------------------------------------------------------------------------------+AMO-DBC -89 DATABASE CONFIGURATIONDISPLAY COMPLETED;DIS-VEGAS;H500: AMO VEGAS STARTEDSYSTEM NO. AMO APS NO. START USER STATUSSWU: L31900Q2999A00001 REGEN P30252B4200B00103 14.11.00 14:33 DAVE A FINISHEDADS: L31900Q2999A00001 REGEN P30252B4200A00103 14.11.00 14:35 DAVE A FINISHEDAMO-VEGAS-107 ADMIN. OF DATABASE GENERATION RUNS ON SUPPORT SYSTEMDISPLAY COMPLETED;<Cisco 2621 Router Configuration
2621_B#sh versionCisco Internetwork Operating System SoftwareIOS (tm) C2600 Software (C2600-JS-M), Version 12.2(3.5)T, MAINTENANCE INTERIM SOFTWARETAC Support: http://www.cisco.com/tacCopyright (c) 1986-2001 by cisco Systems, Inc.Compiled Fri 03-Aug-01 22:45 by ccaiImage text-base: 0x80008088, data-base: 0x81631DD8ROM: System Bootstrap, Version 12.1(3r)T2, RELEASE SOFTWARE (fc1)2621_B uptime is 16 hours, 6 minutesSystem returned to ROM by power-onSystem image file is "flash:c2600-js-mz.122-3.5.T"cisco 2621 (MPC860) processor (revision 0x200) with 56320K/9216K bytes of memory.Processor board ID JAD051516TX (503811939)M860 processor: part number 0, mask 49Channelized E1, Version 1.0.Bridging software.X.25 software, Version 3.0.0.SuperLAT software (copyright 1990 by Meridian Technology Corp).TN3270 Emulation software.Primary Rate ISDN software, Version 1.1.2 FastEthernet/IEEE 802.3 interface(s)31 Serial network interface(s)2 Channelized E1/PRI port(s)32K bytes of non-volatile configuration memory.16384K bytes of processor board System flash (Read/Write)Configuration register is 0x21022621_B#_______________________________________________________________________________________ __2621_B#sh diagSlot 0:C2621 2FE Mainboard Port adapter, 2 portsPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware Revision : 2.0PCB Serial Number : JAD051516TX (503811939)Part Number : 73-3200-08RMA History : 00RMA Number : 0-0-0-0Board Revision : A0Deviation Number : 0-21249EEPROM format version 4EEPROM contents (hex):0x00: 04 FF 40 00 A2 41 02 00 C1 17 4A 41 44 30 35 310x10: 35 31 36 54 58 20 28 35 30 33 38 31 31 39 33 390x20: 29 82 49 0C 80 08 04 00 81 00 00 00 00 42 41 300x30: 80 00 00 53 01 FF FF FF FF FF FF FF FF FF FF FF0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FFSlot 1:High Density Voice Port adapterPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware Revision : 1.1Top Assy. Part Number : 800-03567-01Board Revision : F1Deviation Number : 0-0Fab Version : 02PCB Serial Number : JAB05080LU9RMA Test History : 00RMA Number : 0-0-0-0RMA History : 00EEPROM format version 4EEPROM contents (hex):0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 010x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 300x20: 35 30 38 30 4C 55 39 03 00 81 00 00 00 00 04 000x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FFVIC Slot 0:E1 (2 Port) Multi-Flex Trunk WAN Daughter CardHardware revision 1.0 Board revision B0Serial number 18801733 Part number 800-04479-01Test history 0x0 RMA number 00-00-00Connector type PCIEEPROM format version 1EEPROM contents (hex):0x20: 01 23 01 00 01 1E E4 45 50 11 7F 01 00 00 00 000x30: 58 00 00 00 00 03 09 00 FF FF FF FF FF FF FF FFHDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyalaHDV memory size 524280 heap free 1750652621_B#_______________________________________________________________________________________ __2621_B#sh controllers e1 1/0E1 1/0 is up.Applique type is Channelized E1 - balancedNo alarms detected.alarm-trigger is not setVersion info Firmware: 20010710, FPGA: 15Framing is CRC4, Line Code is HDB3, Clock Source is Line.Data in current interval (71 seconds elapsed):0 Line Code Violations, 0 Path Code Violations0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs2621_B#_______________________________________________________________________________________ __2621_B#sh configurationUsing 1813 out of 29688 bytes!version 12.2no parser cacheservice timestamps debug datetime msec localtime show-timezoneservice timestamps log uptimeno service password-encryption!hostname 2621_B!no logging bufferedenable password cisco!!!memory-size iomem 15voice-card 1dspfarm!ip subnet-zero!!no ip domain-lookup!isdn switch-type primary-net5!!voice class codec 1codec preference 1 g729r8codec preference 2 g711ulawcodec preference 3 g711alaw!!!!!!!controller E1 1/0pri-group timeslots 1-31!controller E1 1/1!!!!interface FastEthernet0/0ip address 192.168.100.2 255.255.255.0no ip mroute-cacheload-interval 30no keepalivespeed autohalf-duplex!interface FastEthernet0/1ip address 10.1.1.129 255.255.255.0no ip mroute-cacheduplex autospeed auto!interface Serial1/0:15no ip addressno logging event link-statusisdn switch-type primary-net5isdn incoming-voice voiceisdn T321 40000isdn T203 30000isdn T306 60000isdn T310 30000isdn bchan-number-order ascendingno cdp enable!router ripnetwork 1.0.0.0network 192.168.100.0!ip classlessno ip http serverip pim bidir-enable!dialer-list 1 protocol ip permitdialer-list 1 protocol ipx permit!!snmp-server packetsize 4096snmp-server managertftp-server nvramcall rsvp-sync!voice-port 1/0:15!!mgcp profile default!dial-peer cor custom!!!dial-peer voice 1 potsdestination-pattern 5...direct-inward-dialport 1/0:15prefix 5!dial-peer voice 3 voipdestination-pattern 2...progress_ind setup enable 1voice-class codec 1session target ipv4:10.1.1.2dtmf-relay h245-alphanumeric!!line con 0exec-timeout 0 0line aux 0exec-timeout 0 0line vty 0 4exec-timeout 0 0password ciscologinline vty 5 15exec-timeout 0 0login!scheduler allocate 3996 1000!end2621_B#
Posted: Thu Sep 6 13:17:09 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.