Table Of Contents
Cisco Systems Equipment Needed
Configuring the Lucent/Avaya Definity G3si PBX
Calling Name and Number Feature
Lucent/Avaya Definity G3si Software Release
Cisco 2621 Router Configuration
Application Note
Lucent/Avaya Definity G3si V9 PBX with CallManager using Cisco 2621-E1 PRI NET5 Gateway
This application note discusses the integration of the Lucent/Avaya Definity G3si V9 PBX with CallManager using the Cisco 2621-E1 PRI NET5 Gateway.
Integration Description
Connectivity is achieved by using the ETSI standard PRI protocol. The Lucent/Avaya Definity G3si can be configured as either the NETWORK or USER side. The figure below shows the general network layout for the integration.
Network Layout
Cisco Systems Equipment Needed
•Hardware (Cisco 2621 Gateway): 2MFT E1 Port
•Software: CallManager Release 3.1
PBX Requirements
•Hardware: TN464F, DS1 INTFC 24/32.
•Software: Version V9
Features
Key features supported:
•Calling/Called Number
•Calling Name
Key features not supported:
•Connected Name
•Connected Number
Configuring the Lucent/Avaya Definity G3si PBX
To configure the Lucent/Avaya Definity G3si PBX, do the following:
Step 1. Add the new circuit pack.
Step 2. Add the new signaling group.
Step 3. Add the new trunk group.
Step 4. Add the Uniform Dialing Plan.
Circuit Pack
The following figures show the configuration of the DS1 circuit pack.
DS1 Circuit Pack
Signaling Group
The following figure shows the configuration of the signaling group.
Signaling Group
Trunk Group
The following figures show the configuration of the trunk group.
Trunk Group
Trunk Group—Trunk Features
Trunk Group—Group Member Assignments
Trunk Group—Group Member Assignments Continued
Uniform Dialing Plan
The following figures show the configuration of the uniform dialing plan.
Dial Plan Record
Uniform Dialing Plan
Configuring Cisco CallManager
To configure Cisco CallManager, do the following:
Step 1. Configure the gateway.
Step 2. Configure the route pattern.
Gateway Configuration
The following figures show the configuration of the Cisco 2621 H.323 Gateway.
Cisco 2621 H.323 Gateway Configuration
Cisco 2621 H.323 Gateway Configuration Continued
Cisco 2621 H.323 Gateway Configuration Continued
Route Pattern Configuration
The following figures show the configuration of the route pattern.
Route Pattern Configuration
Route Pattern Configuration Continued
Considerations
Calling Name and Number Feature
When calling from a Cisco 7960 IP phone to a Lucent/Avaya digital phone, the Lucent/Avaya phone displays the Calling Name and Number after the call is answered as expected. The Cisco 7960 phone, however, displays only the Called Number but not the Connected Name, even though Lucent/Avaya PBX is sending both the Connected Name and the Connected Number IE information in the CONNECT message back to the Cisco 2621 Gateway.
When calling from a Lucent/Avaya digital phone to a Cisco 7960 IP phone, the IP phone displays the Connected Name and Number after the call is answered. The Lucent/Avaya phone, however, does not display the Called Name or Called Number. It displays the numbers being dialed instead (that is the Access Code and the extension number). It was verified using an ISDN protocol analyzer that the CallManager was not sending Connected Name or Connected Number information in the connect message back to PBX.
Integration Testing
This section contains information about the setup used in testing the integration of the Lucent/Avaya Definity G3si and the Cisco 2621-E1 PRI NET5 Gateway.
CallManager Software Release
The following figure shows the information about the release of CallManager being used.
CallManager Software Release
Lucent/Avaya Definity G3si Software Release
The following release of the Lucent/Avaya Definity G3si was used:
•System: G3siV6
•Software Version: G3V9i.02.0.033.2
Cisco 2621 Router Configuration
The following shows the configuration of the Cisco 2621 router.
2621_B#show version
Cisco Internetwork Operating System Software
IOS (tm) C2600 Software (C2600-JS-M), Version 12.2(3.5)T, MAINTENANCE INTERIM SOFTWARE
TAC Support: http://www.cisco.com/tac
Copyright (c) 1986-2001 by cisco Systems, Inc.
Compiled Fri 03-Aug-01 22:45 by ccai
Image text-base: 0x80008088, data-base: 0x81631DD8
ROM: System Bootstrap, Version 12.1(3r)T2, RELEASE SOFTWARE (fc1)
2621_B uptime is 4 minutes
System returned to ROM by power-on
System image file is "flash:c2600-js-mz.122-3.5.T"
cisco 2621 (MPC860) processor (revision 0x200) with 56320K/9216K bytes of memory
.
Processor board ID JAD051516TX (503811939)
M860 processor: part number 0, mask 49
Channelized E1, Version 1.0.
Bridging software.
X.25 software, Version 3.0.0.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
TN3270 Emulation software.
Primary Rate ISDN software, Version 1.1.
2 FastEthernet/IEEE 802.3 interface(s)
31 Serial network interface(s)
2 Channelized E1/PRI port(s)
32K bytes of non-volatile configuration memory.
16384K bytes of processor board System flash (Read/Write)
Configuration register is 0x2102
2621_B#
______________________________________________________________________________________
2621_B#show diag
Slot 0:
C2621 2FE Mainboard Port adapter, 2 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 2.0
PCB Serial Number : JAD051516TX (503811939)
Part Number : 73-3200-08
RMA History : 00
RMA Number : 0-0-0-0
Board Revision : A0
Deviation Number : 0-21249
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 A2 41 02 00 C1 17 4A 41 44 30 35 31
0x10: 35 31 36 54 58 20 28 35 30 33 38 31 31 39 33 39
0x20: 29 82 49 0C 80 08 04 00 81 00 00 00 00 42 41 30
0x30: 80 00 00 53 01 FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Slot 1:
High Density Voice Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 1.1
Top Assy. Part Number : 800-03567-01
Board Revision : F1
Deviation Number : 0-0
Fab Version : 02
PCB Serial Number : JAB05080LU9
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 01
0x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 30
0x20: 35 30 38 30 4C 55 39 03 00 81 00 00 00 00 04 00
0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
VIC Slot 0:
E1 (2 Port) Multi-Flex Trunk WAN Daughter Card
Hardware revision 1.0 Board revision B0
Serial number 18801733 Part number 800-04479-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 23 01 00 01 1E E4 45 50 11 7F 01 00 00 00 00
0x30: 58 00 00 00 00 03 09 00 FF FF FF FF FF FF FF FF
HDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyala
HDV memory size 524280 heap free 175065
2621_B#
______________________________________________________________________________________
2621_B#show controllers e1 1/0
E1 1/0 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
alarm-trigger is not set
Version info Firmware: 20010710, FPGA: 15
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (62 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
2621_B#
____________________________________________________________________________________
2621_B#show configuration
Using 1785 out of 29688 bytes
!
version 12.2
no parser cache
service timestamps debug datetime msec localtime show-timezone
service timestamps log uptime
no service password-encryption
!
hostname 2621_B
!
no logging buffered
enable password cisco
!
!
!
memory-size iomem 15
voice-card 1
dspfarm
!
ip subnet-zero
!
!
no ip domain-lookup
!
isdn switch-type primary-net5
!
!
voice class codec 1
codec preference 1 g729r8
codec preference 2 g711ulaw
codec preference 3 g711alaw
!
!
!
!
!
!
!
controller E1 1/0
pri-group timeslots 1-31
!
controller E1 1/1
shutdown
!
!
!
!
interface FastEthernet0/0
ip address 192.168.100.2 255.255.255.0
no ip mroute-cache
load-interval 30
no keepalive
speed auto
half-duplex
!
interface FastEthernet0/1
ip address 10.1.1.129 255.255.255.0
no ip mroute-cache
duplex auto
speed auto
!
interface Serial1/0:15
no ip address
no logging event link-status
isdn switch-type primary-net5
isdn protocol-emulate network
isdn incoming-voice voice
isdn T321 40000
isdn T203 30000
isdn bchan-number-order ascending
no cdp enable
!
router rip
network 1.0.0.0
network 192.168.100.0
!
ip classless
no ip http server
ip pim bidir-enable
!
dialer-list 1 protocol ip permit
dialer-list 1 protocol ipx permit
!
!
snmp-server packetsize 4096
snmp-server manager
tftp-server nvram
call rsvp-sync
!
voice-port 1/0:15
!
!
mgcp profile default
!
dial-peer cor custom
!
!
!
dial-peer voice 1 pots
destination-pattern 2...
direct-inward-dial
port 1/0:15
prefix 2
!
dial-peer voice 3 voip
destination-pattern 4...
progress_ind setup enable 1
voice-class codec 1
session target ipv4:10.1.1.2
dtmf-relay h245-alphanumeric
!
!
line con 0
exec-timeout 0 0
line aux 0
exec-timeout 0 0
line vty 0 4
exec-timeout 0 0
password cisco
login
line vty 5 15
exec-timeout 0 0
login
!
scheduler allocate 3996 1000
!
end
2621_B#
Test Configuration
The following figure represents the various configurations used for testing.
Testbed Network Configuration
As shown in the figure above, a Lucent/Avaya Definity G3si PBX was connected via an ISDN E1 PRI link to a Cisco 2621 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 2621 and the PBX.
Layer 1 (Physical Layer)
The Lucent/Avaya Definity G3si PBX configuration screen for the E1 trunk interface is reached using the change ds1 a12 command, which sets the E1 physical layer parameters.
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/2621 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 2621 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 2621 Gateway with ISDN protocol type setting of primary-net5 supports both protocol sides by using the isdn protocol-emulate network/user command.
The Lucent/Avaya Definity G3si PBX supports both "USER" and "NETWORK" protocol sides by using the change ds1 a12 command.
Test Results
Testing was performed by Test Engineer(s): Samir Batio, October 4, 2001
Test 1
In test 1:
•The PBX1 country-protocol is set to ETSI to emulate the Network.
•The Cisco 2621 Gateway is configured as a Primary-net5 to emulate the User.
The results are shown in the following tables.
Table 1 Basic Calls (Enbloc Sending)
Calls Made Call Comp? Calling Number passed to final destination? Calling Name passed to final destination? Called Number passed to original side? Called Name passed to the original side?Phone A to Phone C
Yes
Yes
Yes
No1
No1
Phone C to Phone A
Yes
Yes
Yes
Yes
No
1 CallManager is not sending the Connected Name or the Connected Number information in the connect message back to PBX.
Test 2
In test 2:
•The PBX1 country-protocol is set to ETSI to emulate the User.
•The Cisco 2621 Gateway is configured as a Primary-net5 to emulate the Network.
The test results are identical to those in Test 1.
Posted: Thu Sep 6 12:07:43 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.