Table Of Contents
Cisco Systems Equipment needed
Inter-Tel Hardware and Software Requirements
Configuring the Inter-Tel Key System
Calling Name and Number Feature
Catalyst 6000 Switch Configuration
Application Note
Inter-Tel Key System with CallManager using 6608-T1 PRI NI-2 Gateway
This application note illustrates for connectivity of Inter-Tel Key System with CallManager using 6608-T1 PRI NI-2 Gateway.
Integration Description
Connectivity is achieved by using the industry standard PRI NI-2 protocol. The Inter-Tel system can be configured as USER side only.
Cisco Systems Equipment needed
Hardware (Gateway): 6608 T1 Port
Software: CallManager Release 3.1
Inter-Tel Hardware and Software Requirements
Hardware: Axxess 256
Software: Version 5.2
Features Supported
Key features supported:
Calling/Called Number
Key features not supported:
Calling/Called Name
Network Diagram
Figure 1
Network Test Topology
Configuring the Inter-Tel Key System
Configure in the following sequence:
1.
"Configure T1 Trunk" on page 3
2.
"Configure B-Channels Circuits" on page 4
3.
"Configure Reference Clock" on page 6
4.
"Configure T1 PRI Timers" on page 7
5.
"Configure Call Routing Table" on page 8
Configure T1 Trunk
Configure B-Channels Circuits
Configure Reference Clock
Configure T1 PRI Timers
Configure Call Routing Table
Configuring Cisco CallManager
6680 Gateway Configuration
Route Pattern Configuration
Considerations
Calling Name and Number Feature
Calling Name delivery and presentation features are not supported by the Inter-Tel Key System for PRI link.
When calling from Cisco 7960 IP phone to Inter-Tel digital phone, Calling/Called Number is displayed on both phones after the call is answered as expected.
When calling from Inter-Tel digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Inter-Tel phone however does NOT get updated when the call is answered. It displays the numbers being dialed instead. (i.e. Access Code, extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to Inter-Tel Key System.
Appendix A
CallManager Software Release
Inter-Tel Software Release
Catalyst 6000 Switch Configuration
Console> sh versionWS-C6006 Software, Version NmpSW: 5.5(6a)Copyright (c) 1995-2001 by Cisco SystemsNMP S/W compiled on Feb 23 2001, 10:23:18System Bootstrap Version: 5.3(1)Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172Mod Port Model Serial # Versions--- ---- ------------------- ----------- --------------------------------------1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0Fw : 5.3(1)Fw1: 5.4(2)Sw : 5.5(6a)Sw1: 5.5(6a)WS-F6K-PFC SAD05020221 Hw : 1.13 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4Fw : 5.4(2)Sw : 5.5(6a)WS-F6K-VPWR Hw : 1.04 24 WS-X6624-FXS SAD050203M8 Hw : 3.0Fw : 5.4(2)Sw : 5.5(6a)HP : A00203010007; DSP : A003C031 (3.3.30)5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1Fw : 5.4(2)Sw : 5.5(6a)HP1: D00403010013; DSP1: D005C031 (3.3.30)HP2: D00403010013; DSP2: D005C031 (3.3.30)HP3: D00403010013; DSP3: D005C031 (3.3.30)HP4: D00403010013; DSP4: D005C031 (3.3.30)HP5: D00403010013; DSP5: D005C031 (3.3.30)HP6: D00403010013; DSP6: D005C031 (3.3.30)HP7: D00403010013; DSP7: D005C031 (3.3.30)HP8: D00403010013; DSP8: D005C031 (3.3.30)6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1Fw : 5.4(2)Sw : 5.5(6a)HP1: D00403010013; DSP1: D005C031 (3.3.30)HP2: D00403010013; DSP2: D005C031 (3.3.30)HP3: D00403010013; DSP3: D005C031 (3.3.30)HP4: D00403010013; DSP4: D005C031 (3.3.30)HP5: D00403010013; DSP5: D005C031 (3.3.30)HP6: D00403010013; DSP6: D005C031 (3.3.30)HP7: D00403010013; DSP7: D005C031 (3.3.30)HP8: D00403010013; DSP8: D005C031 (3.3.30)DRAM FLASH NVRAMModule Total Used Free Total Used Free Total Used Free------ ------- ------- ------- ------- ------- ------- ----- ----- -----1 65408K 37527K 27881K 16384K 11546K 4838K 512K 198K 314KUptime is 22 days, 23 hours, 13 minutesConsole>______________________________________________________________________________Console> sh moduleMod Slot Ports Module-Type Model Sub Status--- ---- ----- ------------------------- ------------------- --- --------1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok4 4 24 FXS WS-X6624-FXS no ok5 5 8 T1 WS-X6608-T1 no ok6 6 8 E1 WS-X6608-E1 no okMod Module-Name Serial-Num--- ------------------- -----------1 SAD05010NBK3 SAD04420N7B4 SAD050203M85 SAD04400EM06 SAD04380DW1Mod MAC-Address(es) Hw Fw Sw--- -------------------------------------- ------ ---------- -----------------1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)00-04-c0-f8-42-00 to 00-04-c0-f8-42-0100-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)Mod Sub-Type Sub-Model Sub-Serial Sub-Hw--- ----------------------- ------------------- ----------- ------1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.13 Inline Power Module WS-F6K-VPWR 1.0Console>______________________________________________________________________________Console> sh port 5Port Name Status Vlan Duplex Speed Type----- ------------------ ---------- ---------- ------ ----- ------------5/1 notconnect 1 full 1.544 T15/2 connected 1 full 1.544 T15/3 notconnect 1 full 1.544 T15/4 notconnect 1 full 1.544 T15/5 notconnect 1 full 1.544 T15/6 notconnect 1 full 1.544 T15/7 notconnect 1 full 1.544 T15/8 notconnect 1 full 1.544 T1Port DHCP MAC-Address IP-Address Subnet-Mask-------- ------- ----------------- --------------- ---------------5/1 enable 00-01-c9-d9-3a-98 10.1.1.107 255.255.255.05/2 enable 00-01-c9-d9-3a-99 10.1.1.108 255.255.255.05/3 enable 00-01-c9-d9-3a-9a 10.1.1.109 255.255.255.05/4 enable 00-01-c9-d9-3a-9b 10.1.1.110 255.255.255.05/5 enable 00-01-c9-d9-3a-9c 10.1.1.111 255.255.255.05/6 enable 00-01-c9-d9-3a-9d 10.1.1.112 255.255.255.05/7 enable 00-01-c9-d9-3a-9e 10.1.1.113 255.255.255.05/8 enable 00-01-c9-d9-3a-9f 10.1.1.114 255.255.255.0Port Call-Manager(s) DHCP-Server TFTP-Server Gateway-------- ----------------- --------------- --------------- ---------------5/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.75/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7Port DNS-Server(s) Domain-------- ----------------- -------------------------------------------------5/1 - -5/2 - -5/3 - -5/4 - -5/5 - -5/6 - -5/7 - -5/8 - -Port CallManagerState DSP-Type-------- ---------------- --------5/1 registered C5495/2 registered C5495/3 registered C5495/4 registered C5495/5 registered C5495/6 registered C5495/7 registered C5495/8 registered C549Port NoiseRegen NonLinearProcessing----- ---------- -------------------5/1 enabled enabled5/2 enabled enabled5/3 enabled enabled5/4 enabled enabled5/5 enabled enabled5/6 enabled enabled5/7 enabled enabled5/8 enabled enabledConsole>Test Configuration
Figure 2
Test Topology
The above diagram is representative of the various configurations used for testing.
As shown in the diagram above, an Inter-Tel Axxess 256 Key System was connected via an ISDN T1 PRI link to a Cisco 6608-T1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-T1 and the Key System.
Layer 1 (Physical Layer)
The Inter-Tel configuration screen for the T1 PRI trunk's physical layer parameters are under System ->Cabinets -> T1 Primary Rate Interface screen.
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each Inter-Tel/6608 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 6608-T1 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 6608-T1 Gateway with ISDN protocol type setting of PRI-NI2 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The Inter-Tel T1 PRI, when set to NI2, supports "USER" protocol side only. Therefore Cisco 6608-T1 should be configured as Network side.
Test Results
Testing was performed by Test Engineer(s): Samir Batio, August 24, 2001
Test Setup 1
Test configuration:
•
PBX1 configured as NI2, emulates User
•
Cisco 6608-T1 Gateway configured as PRI NI2, emulates Network
Table 1 Test Setup 1 Switch and Gateway Settings
Inter-Tel Axxess 256 Switch-type/ Protocol -side Setting Cisco 6608-T1 ISDN Protocol/Protocol-side SettingNI2/User
PRI NI2/Network
Table 2 Basic Calls: (Enbloc Sending)
Calls Made Call Comp? "Calling Number" Passed to Final Destination? "Calling Name" Passed to Final Destination? "Called Number" Passed to Orig. Side? "Called Name" Passed to Orig. Side? Notes Phone A to Phone CYes
Yes
No
No1
No2
Phone C to Phone AYes
Yes
No
Yes
No
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
2 The Inter-Tel PRI interface with NI2 setting does not support "Calling Name" presentation Feature.
Posted: Thu Sep 6 12:07:33 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.