Table Of Contents
Cisco Systems Equipment Needed
Configuring the Lucent/Avaya Definity G3si PBX
Calling Name and Number Feature
Lucent/Avaya Definity G3si Software Release
Catalyst 6000 Switch Configuration
Application Note
Lucent/Avaya Definity G3si V9 PBX with CallManager using the Cisco 6608-T1 PRI NI-2 Gateway
This application note discusses the integration of the Lucent/Avaya Definity G3si V9 PBX with CallManager using the Cisco 6608-T1 PRI NI-2 Gateway.
Integration Description
Connectivity is achieved by using the industry standard PRI NI-2 protocol. The Lucent/Avaya Definity G3si can be configured as either the NETWORK or USER side. The figure below shows the general network layout for the integration.
Network Layout
Cisco Systems Equipment Needed
•Hardware (Gateway): Cisco 6608 T1 Port
•Software: CallManager Release 3.1
PBX Requirements
•Hardware: TN464F, DS1 INTFC 24/32
•Software: Version V9
Features
Key features supported:
•Calling/Called Number
•Calling/Called Name
Key features not supported:
•Connected Number
Configuring the Lucent/Avaya Definity G3si PBX
To configure the Lucent/Avaya Definity G3si PBX, do the following:
Step 1. Add the new circuit pack.
Step 2. Add the new signaling group.
Step 3. Add the new trunk group.
Step 4. Add the Uniform Dialing Plan.
Circuit Pack
The following figures show the configuration of the DS1 circuit pack.
DS1 Circuit Pack
DS1 Circuit Pack—ESF Data Link Options
Signaling Group
The following figure shows the configuration of the signaling group.
Signaling Group
Trunk Group
The following figures show the configuration of the trunk group.
Trunk Group
Trunk Group—Trunk Features
Trunk Group—Group Member Assignments
Trunk Group—Group Member Assignments Continued
Uniform Dialing Plan
The following figures show the configuration of the uniform dialing plan.
Dial Plan Record
Uniform Dialing Plan
Configuring Cisco CallManager
To configure Cisco CallManager, do the following:
Step 1. Configure the gateway.
Step 2. Configure the route pattern.
Gateway Configuration
The following figures show the configuration of the Cisco 6608 Gateway.
Cisco 6608 Gateway Configuration
Cisco 6608 Gateway Configuration Continued
Cisco 6608 Gateway Configuration Continued
Cisco 6608 Gateway Configuration Continued
Route Pattern Configuration
The following figures show the configuration of the route pattern.
Route Pattern Configuration
Route Pattern Configuration Continued
Considerations
Calling Name and Number Feature
When calling from a Cisco 7960 IP phone to a Lucent/Avaya digital phone, Calling Name and Number are displayed on both phones after the call is answered as expected.
When calling from a Lucent/Avaya digital phone to a Cisco 7960 IP phone, the IP phone displays the Connected Name and Number after the call is answered. The Lucent/Avaya phone, however, displays only the Called Name but not the Called Number. It was verified using an ISDN protocol analyzer that the CallManager was not sending Connected Number information in the connect message back to PBX. Only the Connected Name was sent in the connect message.
Integration Testing
This section contains information about the setup used in testing the integration of the Lucent/Avaya Definity G3si and the Cisco 6608-T1 PRI NI-2 Gateway.
CallManager Software Release:
The following figure shows the information about the release of CallManager being used.
CallManager Software Release
Lucent/Avaya Definity G3si Software Release
The following release of the Lucent/Avaya Definity G3si was used:
•System: G3siV6
•Software Version: G3V9i.02.0.033.2
Catalyst 6000 Switch Configuration
The following shows the configuration of the Catalyst 6000 Switch.
Console> (enable) show version
WS-C6006 Software, Version NmpSW: 5.5(6a)
Copyright (c) 1995-2001 by Cisco Systems
NMP S/W compiled on Feb 23 2001, 10:23:18
System Bootstrap Version: 5.3(1)
Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172
Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0
Fw : 5.3(1)
Fw1: 5.4(2)
Sw : 5.5(6a)
Sw1: 5.5(6a)
WS-F6K-PFC SAD05020221 Hw : 1.1
3 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4
Fw : 5.4(2)
Sw : 5.5(6a)
WS-F6K-VPWR Hw : 1.0
4 24 WS-X6624-FXS SAD050203M8 Hw : 3.0
Fw : 5.4(2)
Sw : 5.5(6a)
HP : A00203010010; DSP : A003E031 (3.3.32)
5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.32)
HP2: D00403010017; DSP2: D005E031 (3.3.32)
HP3: D00403010017; DSP3: D005E031 (3.3.32)
HP4: D00403010017; DSP4: D005E031 (3.3.32)
HP5: D00403010017; DSP5: D005E031 (3.3.32)
HP6: D00403010017; DSP6: D005E031 (3.3.32)
HP7: D00403010017; DSP7: D005E031 (3.3.32)
HP8: D00403010017; DSP8: D005E031 (3.3.32)
6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.32)
HP2: D00403010017; DSP2: D005E031 (3.3.32)
HP3: D00403010017; DSP3: D005E031 (3.3.32)
HP4: D00403010017; DSP4: D005E031 (3.3.32)
HP5: D00403010017; DSP5: D005E031 (3.3.32)
HP6: D00403010017; DSP6: D005E031 (3.3.32)
HP7: D00403010017; DSP7: D005E031 (3.3.32)
HP8: D00403010017; DSP8: D005E031 (3.3.32)
DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 65408K 37863K 27545K 16384K 11546K 4838K 512K 198K 314K
Uptime is 83 days, 2 hours, 34 minutes
Console> (enable) show module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
4 4 24 FXS WS-X6624-FXS no ok
5 5 8 T1 WS-X6608-T1 no ok
6 6 8 E1 WS-X6608-E1 no ok
Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD05010NBK
3 SAD04420N7B
4 SAD050203M8
5 SAD04400EM0
6 SAD04380DW1
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)
00-04-c0-f8-42-00 to 00-04-c0-f8-42-01
00-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff
3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)
4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)
5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)
6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.1
3 Inline Power Module WS-F6K-VPWR 1.0
Console> (enable)
______________________________________________________________________________
Console> (enable) show port 5
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
5/1 notconnect 1 full 1.544 T1
5/2 connected 1 full 1.544 T1
5/3 notconnect 1 full 1.544 T1
5/4 notconnect 1 full 1.544 T1
5/5 notconnect 1 full 1.544 T1
5/6 notconnect 1 full 1.544 T1
5/7 notconnect 1 full 1.544 T1
5/8 notconnect 1 full 1.544 T1
Port DHCP MAC-Address IP-Address Subnet-Mask
-------- ------- ----------------- --------------- ---------------
5/1 enable 00-01-c9-d9-3a-98 10.1.1.107 255.255.255.0
5/2 enable 00-01-c9-d9-3a-99 10.1.1.108 255.255.255.0
5/3 enable 00-01-c9-d9-3a-9a 10.1.1.109 255.255.255.0
5/4 enable 00-01-c9-d9-3a-9b 10.1.1.110 255.255.255.0
5/5 enable 00-01-c9-d9-3a-9c 10.1.1.111 255.255.255.0
5/6 enable 00-01-c9-d9-3a-9d 10.1.1.112 255.255.255.0
5/7 enable 00-01-c9-d9-3a-9e 10.1.1.113 255.255.255.0
5/8 enable 00-01-c9-d9-3a-9f 10.1.1.114 255.255.255.0
Port Call-Manager(s) DHCP-Server TFTP-Server Gateway
-------- ----------------- --------------- --------------- ---------------
5/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
Port DNS-Server(s) Domain
-------- ----------------- -------------------------------------------------
5/1 - -
5/2 - -
5/3 - -
5/4 - -
5/5 - -
5/6 - -
5/7 - -
5/8 - -
Port CallManagerState DSP-Type
-------- ---------------- --------
5/1 registered C549
5/2 registered C549
5/3 registered C549
5/4 registered C549
5/5 registered C549
5/6 registered C549
5/7 registered C549
5/8 registered C549
Port NoiseRegen NonLinearProcessing
----- ---------- -------------------
5/1 enabled enabled
5/2 enabled enabled
5/3 enabled enabled
5/4 enabled enabled
5/5 enabled enabled
5/6 enabled enabled
5/7 enabled enabled
5/8 enabled enabled
Console> (enable)
Test Configuration
The following figure represents the various configurations used for testing.
Testbed Network Configuration
As shown in the figure above, a Lucent/Avaya Definity G3si PBX was connected via an ISDN T1 PRI link to a Cisco 6608-T1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-T1 and the PBX.
Layer 1 (Physical Layer)
The Lucent/Avaya Definity G3si PBX configuration screen for the DS1 trunk interface is reached using the change ds1 a12 command, which sets the T1 physical layer parameters.
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/6608-T1 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 6608-T1 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 6608-T1 Gateway with ISDN protocol type setting of PRI-NI2 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The Lucent/Avaya Definity G3si PBX supports both "USER" and "NETWORK" protocol sides.
Test Results
Testing was performed by Test Engineer(s): Samir Batio, October 2, 2001
Test 1
In test 1:
•The PBX1 country-protocol is set to 1a (US / AT&T TR 41449/41459) to emulate the Network.
•The Cisco 6608-T1 Gateway was configured as a PRI NI2 to emulate the User.
The results are shown in the following tables.
Test 2
In test 2:
•The PBX1 country-protocol is set to 1a (US / AT&T TR 41449/41459) to emulate the User.
•The Cisco 6608-T1 Gateway is configured as a PRI NI2 to emulate the Network.
The test results are identical to those in Test 1.
Posted: Thu Sep 6 12:24:52 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.