Table Of Contents
Cisco Systems Hardware and Software Requirements
PBX Hardware and Software Requirements
Calling Name and Number feature
Configuringthe Siemens Hicom 300 E CS PBX
Siemens Hicom 330 E CS PBX Configuration Menus and Commands
Configuring the Cisco CallManager
Siemens Hicom 330 E CS Software release
Catalyst 6000 Switch Configuration
Application Note
Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 6608-E1 PRI EURO Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager using Cisco 6608-E1 PRI Euro Gateway.
Integration Description
Connectivity is achieved by using the industry standard PRI NI-2 protocol. The Siemens Hicom 300 E CS can be configured as either NETWORK or USER side.
Cisco Systems Hardware and Software Requirements
•Hardware (Gateway): 6608 T1 Port
•Software: CallManager Release 3.1
PBX Hardware and Software Requirements
•Hardware: TMDN or TMDN 64
•Software: Version 6.5
Features Supported
Key Features Supported
Calling/Called Number
Key Features Not Supported
Calling/Called Name
Limitations
Calling Name and Number feature
•Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E CS PBX.
•When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called Number is displayed on both phones after the call is answered.
•When calling from Siemens digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Siemens phone however does NOT get updated when the call is answered. It displays the dialed numbers instead. (i.e. Access Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.
•When a call is answered, the display on the Siemens phone is only active (Calling Number displayed) for approximately 4 seconds. Thereafter, the screen goes blank. This could be caused by a timer feature that is expiring for the display.
Network Topology
Figure 1 Basic Setup
Configuration
Configuringthe Siemens Hicom 300 E CS PBX
Use the following steps to configure the Siemens Hicom 300 E CS PBX:
Step 1. Add the new access code to DPLN
Step 2. Add the new trunk board using BCSU
Step 3. Configure COT
Step 4. Configure COP
Step 5. Add the new trunk group access code using TGACC
Step 6. Add the channels using TCSU
Step 7. Configure LROUT
Step 8. Configure LODR
Siemens Hicom 330 E CS PBX Configuration Menus and Commands
Step 1. Add the new access code to DPLN.
<dis-dpln
TYPE = dgts
DGTS = ;
DIS-DPLN:DGTS,;
H500: AMO DPLN STARTED
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 0 |....* ..... ..... .......| GENANS | | |
| 1 |.*.** *.*** **... ......*| CO | | |
| 2000 - 2002 |.**** ***** ***.* ......*| STN | | |
| 2003 - 2024 |.**** ***** ***.* ......*| STN | R | |
| 2025 - 2026 |.**** ***** ***.* ......*| STN | | |
| 2027 - 2099 |.**** ***** ***.* ......*| STN | R | |
| 37 - 41 |.*.** *.*** **... ......*| CO | | |
| 43 - 48 |.**** ***** **... ......*| TIE | | |
| 49 - 50 |.*.** *.*** **... ......*| CO | | |
| 70000 - 70999 |.**** ***** ***.* ......*| STN | R | |
| 71000 |.**** ***** ***.* ......*| STN | | 1 |
| 71001 - 79998 |.**** ***** ***.* ......*| STN | R | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 79999 |.**** ***** ***.* ......*| STN | | |
| 9 |.*.** *.*** **... ......*| CO | | |
| *0 |*...* ..**. ..... ......*| ACDWORK | | |
| *2 |*...* ..**. ..... ......*| ACCTCODE | | |
| *3 |....* ..**. ..... ......*| PUDIR | | |
| *4 |*...* ..**. ..... ......*| CONFRNC | | |
| *52 |....* ..... ..... .......| MWCAN | | |
| *530 |....* ..... ..... ......*| PMCANCEL | | |
| *532 |....* ..... ..... ......*| PMCALLBK | | |
| *563 |*.... ..**. ..... .......| BADLINE | | |
| *564 |*...* ..**. ..... ......*| ACDLOGON | | |
| *565 |*...* ..**. ..... ......*| ACDLOGOF | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *570 |*...* ..**. ..... .......| ACDPQ | | |
| *571 |*...* ..**. ..... .......| ACDPS | | |
| *572 |....* ..... ..... .......| RING | | |
| *580 |*...* ..**. ..... .......| ACDSQ | | |
| *581 |*...* ..**. ..... .......| ACDSS | | |
| *6 |***** ..**. ..... .......| ROLMPARK | | |
| *7 |*...* ..**. ..... .......| CONSULT | | |
| *80 - *89 |.**** ..**. ..... .......| PARK | | |
| *9 |....* ..**. ..... .......| HOLD | | |
| **0 |.***. ..... ..... .......| BVSL | | |
| **1 |*.... ..**. ..... ......*| TOGGLE | | |
| **3 |....* ..**. ..... ......*| PU | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| **41 - **48 |..... ..*.. ..... ......*| CONFRMV | | |
| **50 |*...* ..**. ..... .......| CAFGRAVL | | |
| **51 |*...* ..**. ..... .......| CAFGRUNA | | |
| **6 |....* ..**. ..... .......| INTERCOM | | |
| **8 |....* ..... ..... .......| MWANS | | |
| ***4 |..... ..... ..... ......*| CONFRMVL | | |
| ***5 |....* ..... ..... .......| MONSLNT | | |
| **#65 |*...* ..**. ..... .......| CAFGROFF | | |
| *#01 |....* ..... ..... .......| RCHNL | | |
| *#02 |....* ..... ..... .......| RTERM | | |
| *#03 |....* ..... ..... .......| LTERM | | |
| *#04 |..... *.... *.... .......| PRITEST | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#274 |*...* ..... ..... .......| WS | | |
| *#50 |*...* ..**. ..... .......| CAFAVLB | | |
| *#51 |*...* ..**. ..... .......| CAFUNAV | | |
| *#55 |*...* ..**. ..... .......| CAFFWD | | |
| *#56 |*...* ..**. ..... .......| CAFFWDC | | |
| *#57 |....* ..... ..... .......| PIDON | | |
| *#58 |....* ..... ..... .......| PIDOFF | | |
| *#590 |....* ..... ..... .......| DCOSX | | |
| *#591 |....* ..... ..... .......| ACOSX | | |
| *#63 |***** ***** ***** *******| CLEAR | | |
| *#65 |*...* ..**. ..... .......| CAFLOGOF | | |
| *#735 |....* ..... ..... .......| RELOCATE | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#738 |....* ..... ..... .......| SET | | |
| *#97 |..*.. *.... ..... .......| COXFER | | |
| #0 |*...* ..**. ..... ......*| ACDUNAV | | |
| #1 |*.... ..*.. ....* .......| ACBK | | |
| #2 |*...* ..**. ..... .......| PRION | | |
| #3 |.**.* ..**. ..... ......*| SPDI | | |
| #4 |***.* ..**. ....* ......*| SNR | | |
| #5 |....* ..... ..... .......| ADND | | |
| #61 |.**** ..*** **... ......*| SPDC1 | | |
| #62 |.**** ..*** **... ......*| SPDC2 | | |
| #80 |*...* ..**. ..... .......| BROADCST | | |
| #81 |*...* ..**. ..... .......| SPKRCALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #8378 |..... ..... ....* .......| HWTEST | | |
| #91 |....* ..... ....* .......| CFWVABTH | | |
| #92 |....* ..... ....* .......| CFWVAEXT | | |
| #93 |....* ..... ....* .......| CFWVAINT | | |
| #94 |....* ..... ....* .......| CFWVB | | |
| #95 |....* ..... ....* .......| CFWVBNA | | |
| #96 |....* ..... ....* .......| CFWVNA | | |
| #*056 |....* ..... *.... .......| DATA56 | | |
| #*1 |***** ..**. ..... .......| MWACT | | |
| #*2 |*...* ..**. ..... .......| BUZZ | | |
| #*329 |.**.* *.*** **... .......| FAX | R | |
| #*4 |*...* ..**. ..... .......| VCECALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*75 |....* ..... ..... .......| DIGIDAT | | |
| #*76 |....* *.**. ..*.* .......| SWITCH | | |
| #*77 |....* *.*** ***.* .......| DTE | | |
| #*78 |....* ..**. ....* .......| CODE | | |
| #*79 |....* ..**. ....* .......| SPEED | | |
| #*8 |***** ****. ..*** *****..| MWCANORI | | |
| #*90 |....* ..... ....* .......| HUNTPROG | | |
| #*92 |....* ..... ..... .......| AHTVCE | | |
| #*93 |....* ..... ..... .......| DHTVCE | | |
| #*94 |....* ..... ..... .......| AHTDTE | | |
| #*95 |....* ..... ..... .......| DHTDTE | | |
| #*96 |....* ..... ..... .......| AHTFAX | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*97 |....* ..... ..... .......| DHTFAX | | |
| #*99 |....* ..... ....* .......| HUNTCLR | | |
| ##0 |*...* ..**. ..... ......*| ACDAVLB | | |
| ##1 |....* ..... ..... .......| DCBK | | |
| ##2 |*...* ..**. ..... .......| PRIOFF | | |
| ##3 |....* ..... ....* .......| SPDIPROG | | |
| ##4 |*...* ..**. ..... ......*| LNR | | |
| ##5 |....* ..... ..... .......| DDND | | |
| ##7 |*.... ..... ..... .....*.| KNOVR | | |
| ##8 |***** ..**. ..... .......| DTA | | |
| ##91 |....* ..... ....* .......| CFWVAOFF | | |
| ##*78 |....* ..**. ....* .......| RESET | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| ###1 |*.... ...*. ..... .......| TRACE | | |
| ###20 |..... **..* **... .......| MILLWAT | | |
| ###21 |..... **..* **... .......| LOOPBACK | | |
| ###22 |..... **..* **... .......| SILENCE | | |
| ###23 |..... **..* **... .......| COMBO | | |
| ###4 |*.... ..... ..... .......| THRCONF | | |
| ###6 |....* ..... ..... .......| MONTONE | | |
--------------------------------------------------------------------------
AMO-DPLN -135 DIALING PLANS, FEATURE ACCESS CODES
DISPLAY COMPLETED;
Step 2. Add the new trunk board using BCSU.
<dis-bcsu
TYPE = tmd;
DIS-BCSU:TMD;
H500: AMO BCSU STARTED
---------------------------------------------------------------
| DETAILS OF TMD BOARD AT ADDRESS (LTG.LTU.SLOT) = 1. 2.103 |
| |
| CABTYP = 1 TIMTYP = SYST SIGTYP = MOS |
| FRAME = ESF TABS = NO FCTID = 2 |
| BI8SUB = YES BIVDET = NO |
|-------------------------------------------------------------|
| RDRATIO = 6 RDTH = 2500 RDQUAL = 15000 |
| YLSEND = 5000 YLTH = 400 YLQUAL = 100 |
| LOS = 150 AOS = 4000 |
| SESDISTH = 10 SESREQTH = 10 |
| OESDISTH = 30 OESDISIN = 24-00-00 |
| OESREQTH = 4 OESREQIN = 04-00-00 |
|-------------------------------------------------------------|
| NETUSR = NETWK ACKTIM = 1000 DLVTIM = 30000 |
| OCTMAX = 260 RETMAX = 3 WINDOW = 1 |
| CRIDC = TTSC = NSFIV = |
| NSFTSC = PFDGT = | |-------------------------------------------------------------|
| IGN = 0 IID = 1 |
---------------------------------------------------------------
AMO-BCSU -135 BOARD CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Step 3. Configure COT.
<dis-cot
COTNO = 0;
DIS-COT:0;
H500: AMO COT STARTED
|D|A|D|D|D|M|S|V|E|E|A|R|
|I|N|S|S|I|D|A|L|S|S|N|F|
|T|S|A|A|S|R|T|S|P|P|I|L|
| |R| |S| | | |A|A|D|D|A|
| | | | | | | |T|N|N|N|S|
| | | | | | | | |I|I|I|H|
COT | | | | | | | | | |S|S| |
----+-+-+-+-+-+-+-+-+-+-+-+-+
0 | | | | | | | | | | | | |
----+-+-+-+-+-+-+-+-+-+-+-+-+
AMO-COT -135 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;
Step 4. Configure Class of Parameter for device handler using COP.
<dis-cop
COPNO = 0;
DIS-COP:0;
H500: AMO COP STARTED
| | | | | |
| | S E A | | | |
| | T E S N | | | |
| | A S V S P I D |DD| S| |
| | D Z L P D D T |TT| U| P |
| | I A A S S A N N O |MM| P| D |
|COP| A N C A A N I I N |FF| V| P |
|IDX| L S K T T I S S E | L|12|1234|
+---+-------------------+--+--+----+
| 0| | | | |
+---+-------------------+--+--+----+
AMO-COP -135 CLASS OF PARAMETER
DISPLAY COMPLETED;
Step 5. Add the new trunk group access code using TGACC.
<dis-tgacc
TGRP = 40;
DIS-TGACC:40;
H500: AMO TGACC STARTED
+------------------------------------------------------------------------------+
| TGRP NUMBER : 40 TGRP NAME : T1PRI /N MAXIMUM NO: 23 |
| SUBGROUP NUMBER: 11 DEVICE TYPE: PRI B DIR TYPE : BOTH |
| ACD THRESHOLD : * TRACENO : 0 USAGE TYPE: TERR |
| ALLOCATED TO AT LEAST ONE ROUTE GDTR RULE : 0 |
| SELECTION : LOW CFBLOCK : DISABLED |
| THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 2-103- 1| 1- 2-103- 2| 1- 2-103- 3| 1- 2-103- 4| 1- 2-103- 5| 1- 2-103- 6|
+------------------------------------------------------------------------------+
| 1- 2-103- 7| 1- 2-103- 8| 1- 2-103- 9| 1- 2-103-10| 1- 2-103-11| 1- 2-103-12|
+------------------------------------------------------------------------------+
| 1- 2-103-13| 1- 2-103-14| 1- 2-103-15| 1- 2-103-16| 1- 2-103-17| 1- 2-103-18|
+------------------------------------------------------------------------------+
| 1- 2-103-19| 1- 2-103-20| 1- 2-103-21| 1- 2-103-22| 1- 2-103-23| - - - |
+------------------------------------------------------------------------------+
AMO-TGACC-135 TRUNK GROUP ACCESS CODE
DISPLAY COMPLETED;
Step 6. Add the channels using TCSU.
TCSU - B Channel
<dis-tcsu
PEN1 = 1-2-103-1;
DIS-TCSU:1-2-103-1;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103- 1 INS: Y BOARD: TMDN64P DEV: PRIB TGRP: 40 |
+------------------------------------------------------------------------+
| TRKID : 0040 TCCID : |
| CCT : /0040 |
| |
| ACDATA : 0 DITIDX : 0 LOCANA : |
| ATNTYP : ISDN DPLN : 0 REMANA : |
| COPNO : 0 ITR : 0 SIDANI : N |
| COSNO : 75 LCRCOSD : 5 SRTIDX : 3 |
| COTNO : 0 LCRCOSV : 5 TRTBL : DIDCR |
| DEDSVC : NONE FACILITY : * |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
TCSU - D Channel
<dis-tcsu
PEN1 = 1-2-103-24;
DIS-TCSU:1-2-103-24;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103-24 INS: Y BOARD: TMDN64P DEV: PRID |
+------------------------------------------------------------------------+
| TCCID : |
| CCT : |
| |
| ACDATA : 0 DEDSCC : INTERFID : |
| COPNO : 0 DITIDX : ITR : 0 |
| COTNO : 0 DPLN : 0 PROTOCOL : NI2 |
| |
| TMR301 : 300 SEC. TMR308 : 4 SEC. TMR313 : 4 SEC. |
| TMR303 : 4 SEC. TMR309 : 90 SEC. TMR316 : 30 SEC. |
| TMR305 : 30 SEC. TMR310 : 30 SEC. TMR322 : 4 SEC. |
| TDELAY : 3000 MSEC. BEARER: ONE |
| NCT : N TNCT : |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Step 7. Configure LROUT.
<dis-lrout
ROUTE = 40;
DIS-LROUT:40;
H500: AMO LROUT STARTED
LCR ROUTE DEFINITION TABLE
--------------------------
-------------------------------------------------------------------------
|ROUTENUM = 40 SCHED A = X AORT = INFORMATION |
|ROUTEELE = 1 B = AUTH = 1 TRANS CAP = S3V |
|BEARER = ONE C = ONHKQ = Y TRKSIG = PRI |
|BANDWTH = 1 D = OFFHKQ = Y SCCID = |
|TRUNKGRP = 40 E = ODRNUM = 1 SVCVCE = NON |
|MASTGRP = 8 F = APLTYP = VD SVCN-V = NON |
|ROUTSERV = N G = FACNUM = |
| H = |
-------------------------------------------------------------------------
END OF LCR ROUTE DEFINITION TABLE DISPLAY
AMO-LROUT-135 ROUTE DEFINITION DETERMINATION PACKAGE
DISPLAY COMPLETED;
Step 8. Configure LODR.
<dis-lodr
RANGE =
DIS-LODR:;
H500: AMO LODR STARTED
<< DISPLAY LCR OUTDIAL RULE >>
ODR NO COMMAND BRANCH VALUE
------ ------- ------------
1 ECHOALL
END -------- END OF DISPLAY --------AMO-LODR -135 AMO LCR ODR FOR SWITCHING UNIT
DISPLAY COMPLETED;
<
Configuring the Cisco CallManager
Figure 1
Configuring the 6608-E1 Gateway
Route Pattern Configuration
Test Results
As shown in the diagram below, a Siemens Hicom 300 E CS PBX was connected via an ISDN T1 PRI link to a Cisco 6608-T1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-T1 and the PBX.
Test Configuration
Layer 1 (Physical Layer)
The Siemens configuration screen for the DS1 trunk interface is reached with the command:
<cha-bssu
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/6608-T1 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 6608-T1 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 6608-T1 Gateway with ISDN protocol type setting of PRI-NI2 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The "Network/user" choice for the Siemens Hicom 300 E PBX is made by deactivating the B channels/D-channel (<dea-dssu) and the DS1 board (<dea-bssu) consecutively. A change command is then issued to the Board Configuration Switching Unit (BCSU) to get to the "network/user" prompt (<cha-bcsu). The DS1 board by (<act-bssu), the D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
.
Table 2 Basic Calls: (Enbloc Sending)
Calls Made Call Comp? "Calling Number" Passed to Final Destination? "Calling Name" Passed to Final Destination? "Called Number" Passed to Orig. Side? "Called Name" Passed to Orig. Side? NotesPhone A to Phone C
Yes
Yes
No
No 1
No
Phone C to Phone A
Yes
Yes
No
Yes
No
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
2 The Siemens PRI interface with ETSI setting does not support "Calling Name" presentation Feature.
3 The display on the Siemens phone is oly active (Calling Number is displayed) for apporximately 4 seconds, thereafter the displays goes blank. This could be caused by a display timer feature that expires.
Test Setup 2
Setup was as follows:
•PBX1 configured as NI2, emulates User
•Cisco 6608-T1 Gateway configured as PRI NI2, emulates Network
.
Table 6 Switch and Gateway Settings
Siemens Hicom 330 E CS Switch-type/ Protocol side setting Cisco 6608-T1 ISDN protocol-type/Protocolside settingNI2/User
PRI NI2 / Network
The test results are the same as in previous section . Refer to Tables 2 through 5 for details.
Appendix A
Call Manager Software Release:
Siemens Hicom 330 E CS Software release
-------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-09-18 11:40:46
-------------------------------------------------------------------------------
<dis-ansu
DIS-ANSU;
H500: AMO ANSU STARTED
APS TYPE | NAME | SP REFERENCE NO.
-------------+----------+------------------
SWU RES-CODE | S0-ET0SC | P30252B6500S00101
SWU AMO-CODE | B0-ET0BC | P30252B6500B00101 SWU RES-TEXT | S0-TTDSD | P30252B650DS00101
SYSTEM NUMBER | DB SUBSYSTEM NAME
------------------+------------------
00000000000095393 | DB_SUSY_ZDBCCDSF
00000000000095393 | DB_SUSY_ZDBCCDS0
00000000000095393 | DB_SUSY_ZDBCCDS1
00000000000095393 | DB_SUSY_ZDBCCDS2
00000000000095393 | DB_SUSY_ZDBCCDSB
00000000000095393 | DB_SUSY_ZDBCCDSC
AMO-ANSU -135 ENTERING THE SYSTEM NUMBERS INTO THE SWU DATABASE
DISPLAY COMPLETED;
<
Catalyst 6000 Switch Configuration
Console> (enable) sh version
WS-C6006 Software, Version NmpSW: 5.5(6a)
Copyright (c) 1995-2001 by Cisco Systems
NMP S/W compiled on Feb 23 2001, 10:23:18
System Bootstrap Version: 5.3(1)
Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172
Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0
Fw : 5.3(1)
Fw1: 5.4(2)
Sw : 5.5(6a)
Sw1: 5.5(6a)
WS-F6K-PFC SAD05020221 Hw : 1.1
3 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4
Fw : 5.4(2)
Sw : 5.5(6a)
WS-F6K-VPWR Hw : 1.0
4 24 WS-X6624-FXS SAD050203M8 Hw : 3.0
Fw : 5.4(2)
Sw : 5.5(6a)
HP : A00203010010; DSP : A003E031 (3.3.
32)
5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)
6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)
DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 65408K 37863K 27545K 16384K 11546K 4838K 512K 198K 314K
Uptime is 83 days, 2 hours, 34 minutes
Console> (enable)
______________________________________________________________________________
Console> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
4 4 24 FXS WS-X6624-FXS no ok
5 5 8 T1 WS-X6608-T1 no ok
6 6 8 E1 WS-X6608-E1 no ok
Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD05010NBK
3 SAD04420N7B
4 SAD050203M8
5 SAD04400EM0
6 SAD04380DW1
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)
00-04-c0-f8-42-00 to 00-04-c0-f8-42-01
00-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff
3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)
4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)
5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)
6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.1
3 Inline Power Module WS-F6K-VPWR 1.0
Console> (enable)
______________________________________________________________________________
Console> (enable) sh port 5
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
5/1 notconnect 1 full 1.544 T1
5/2 connected 1 full 1.544 T1
5/3 notconnect 1 full 1.544 T1
5/4 notconnect 1 full 1.544 T1
5/5 notconnect 1 full 1.544 T1
5/6 notconnect 1 full 1.544 T1
5/7 notconnect 1 full 1.544 T1
5/8 notconnect 1 full 1.544 T1
Port DHCP MAC-Address IP-Address Subnet-Mask
-------- ------- ----------------- --------------- ---------------
5/1 enable 00-01-c9-d9-3a-98 10.1.1.107 255.255.255.0
5/2 enable 00-01-c9-d9-3a-99 10.1.1.108 255.255.255.0
5/3 enable 00-01-c9-d9-3a-9a 10.1.1.109 255.255.255.0
5/4 enable 00-01-c9-d9-3a-9b 10.1.1.110 255.255.255.0
5/5 enable 00-01-c9-d9-3a-9c 10.1.1.111 255.255.255.0
5/6 enable 00-01-c9-d9-3a-9d 10.1.1.112 255.255.255.0
5/7 enable 00-01-c9-d9-3a-9e 10.1.1.113 255.255.255.0
5/8 enable 00-01-c9-d9-3a-9f 10.1.1.114 255.255.255.0
Port Call-Manager(s) DHCP-Server TFTP-Server Gateway
-------- ----------------- --------------- --------------- ---------------
5/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
Port DNS-Server(s) Domain
-------- ----------------- -------------------------------------------------
5/1 - -
5/2 - -
5/3 - -
5/4 - -
5/5 - -
5/6 - -
5/7 - -
5/8 - -
Port CallManagerState DSP-Type
-------- ---------------- --------
5/1 registered C549
5/2 registered C549
5/3 registered C549
5/4 registered C549
5/5 registered C549
5/6 registered C549
5/7 registered C549
5/8 registered C549
Port NoiseRegen NonLinearProcessing
----- ---------- -------------------
5/1 enabled enabled
5/2 enabled enabled
5/3 enabled enabled
5/4 enabled enabled
5/5 enabled enabled
5/6 enabled enabled
5/7 enabled enabled
5/8 enabled enabled
Console> (enable)
Posted: Thu Sep 6 13:02:52 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.