cc/td/doc/product/voice/c_callmg
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Application Note

Integration Description

Cisco Systems Hardware and Software Requirements

PBX Hardware and Software Requirements

Features Supported

Key Features Supported

Key Features Not Supported

Limitations

Calling Name and Number feature

Network Topology

Configuration

Configuringthe Siemens Hicom 300 E CS PBX

Siemens Hicom 330 E CS PBX Configuration Menus and Commands

Configuring the Cisco CallManager

Route Pattern Configuration

Test Results

Appendix A

Siemens Hicom 330 E CS Software release

Catalyst 6000 Switch Configuration


Application Note


Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 6608-E1 PRI EURO Gateway

This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager using Cisco 6608-E1 PRI Euro Gateway.

Integration Description

Connectivity is achieved by using the industry standard PRI NI-2 protocol. The Siemens Hicom 300 E CS can be configured as either NETWORK or USER side.

Cisco Systems Hardware and Software Requirements

Hardware (Gateway): 6608 T1 Port

Software: CallManager Release 3.1

PBX Hardware and Software Requirements

Hardware: TMDN or TMDN 64

Software: Version 6.5

Features Supported

Key Features Supported

Calling/Called Number

Key Features Not Supported

Calling/Called Name

Limitations

Calling Name and Number feature

Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E CS PBX.

When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called Number is displayed on both phones after the call is answered.

When calling from Siemens digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Siemens phone however does NOT get updated when the call is answered. It displays the dialed numbers instead. (i.e. Access Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.

When a call is answered, the display on the Siemens phone is only active (Calling Number displayed) for approximately 4 seconds. Thereafter, the screen goes blank. This could be caused by a timer feature that is expiring for the display.

Network Topology

Figure 1 Basic Setup

Configuration

Configuringthe Siemens Hicom 300 E CS PBX

Use the following steps to configure the Siemens Hicom 300 E CS PBX:


Step 1. Add the new access code to DPLN

Step 2. Add the new trunk board using BCSU

Step 3. Configure COT

Step 4. Configure COP

Step 5. Add the new trunk group access code using TGACC

Step 6. Add the channels using TCSU

Step 7. Configure LROUT

Step 8. Configure LODR

Siemens Hicom 330 E CS PBX Configuration Menus and Commands


Step 1. Add the new access code to DPLN.

<dis-dpln


TYPE = dgts


DGTS = ;


DIS-DPLN:DGTS,;

H500: AMO DPLN STARTED

--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 0 |....* ..... ..... .......| GENANS | | |
| 1 |.*.** *.*** **... ......*| CO | | |
| 2000 - 2002 |.**** ***** ***.* ......*| STN | | |
| 2003 - 2024 |.**** ***** ***.* ......*| STN | R | |
| 2025 - 2026 |.**** ***** ***.* ......*| STN | | |
| 2027 - 2099 |.**** ***** ***.* ......*| STN | R | |
| 37 - 41 |.*.** *.*** **... ......*| CO | | |
| 43 - 48 |.**** ***** **... ......*| TIE | | |
| 49 - 50 |.*.** *.*** **... ......*| CO | | |
| 70000 - 70999 |.**** ***** ***.* ......*| STN | R | |
| 71000 |.**** ***** ***.* ......*| STN | | 1 |
| 71001 - 79998 |.**** ***** ***.* ......*| STN | R | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 79999 |.**** ***** ***.* ......*| STN | | |
| 9 |.*.** *.*** **... ......*| CO | | |
| *0 |*...* ..**. ..... ......*| ACDWORK | | |
| *2 |*...* ..**. ..... ......*| ACCTCODE | | |
| *3 |....* ..**. ..... ......*| PUDIR | | |
| *4 |*...* ..**. ..... ......*| CONFRNC | | |
| *52 |....* ..... ..... .......| MWCAN | | |
| *530 |....* ..... ..... ......*| PMCANCEL | | |
| *532 |....* ..... ..... ......*| PMCALLBK | | |
| *563 |*.... ..**. ..... .......| BADLINE | | |
| *564 |*...* ..**. ..... ......*| ACDLOGON | | |
| *565 |*...* ..**. ..... ......*| ACDLOGOF | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *570 |*...* ..**. ..... .......| ACDPQ | | |
| *571 |*...* ..**. ..... .......| ACDPS | | |
| *572 |....* ..... ..... .......| RING | | |
| *580 |*...* ..**. ..... .......| ACDSQ | | |
| *581 |*...* ..**. ..... .......| ACDSS | | |
| *6 |***** ..**. ..... .......| ROLMPARK | | |
| *7 |*...* ..**. ..... .......| CONSULT | | |
| *80 - *89 |.**** ..**. ..... .......| PARK | | |
| *9 |....* ..**. ..... .......| HOLD | | |
| **0 |.***. ..... ..... .......| BVSL | | |
| **1 |*.... ..**. ..... ......*| TOGGLE | | |
| **3 |....* ..**. ..... ......*| PU | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| **41 - **48 |..... ..*.. ..... ......*| CONFRMV | | |
| **50 |*...* ..**. ..... .......| CAFGRAVL | | |
| **51 |*...* ..**. ..... .......| CAFGRUNA | | |
| **6 |....* ..**. ..... .......| INTERCOM | | |
| **8 |....* ..... ..... .......| MWANS | | |
| ***4 |..... ..... ..... ......*| CONFRMVL | | |
| ***5 |....* ..... ..... .......| MONSLNT | | |
| **#65 |*...* ..**. ..... .......| CAFGROFF | | |
| *#01 |....* ..... ..... .......| RCHNL | | |
| *#02 |....* ..... ..... .......| RTERM | | |
| *#03 |....* ..... ..... .......| LTERM | | |
| *#04 |..... *.... *.... .......| PRITEST | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#274 |*...* ..... ..... .......| WS | | |
| *#50 |*...* ..**. ..... .......| CAFAVLB | | |
| *#51 |*...* ..**. ..... .......| CAFUNAV | | |
| *#55 |*...* ..**. ..... .......| CAFFWD | | |
| *#56 |*...* ..**. ..... .......| CAFFWDC | | |
| *#57 |....* ..... ..... .......| PIDON | | |
| *#58 |....* ..... ..... .......| PIDOFF | | |
| *#590 |....* ..... ..... .......| DCOSX | | |
| *#591 |....* ..... ..... .......| ACOSX | | |
| *#63 |***** ***** ***** *******| CLEAR | | |
| *#65 |*...* ..**. ..... .......| CAFLOGOF | | |
| *#735 |....* ..... ..... .......| RELOCATE | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#738 |....* ..... ..... .......| SET | | |
| *#97 |..*.. *.... ..... .......| COXFER | | |
| #0 |*...* ..**. ..... ......*| ACDUNAV | | |
| #1 |*.... ..*.. ....* .......| ACBK | | |
| #2 |*...* ..**. ..... .......| PRION | | |
| #3 |.**.* ..**. ..... ......*| SPDI | | |
| #4 |***.* ..**. ....* ......*| SNR | | |
| #5 |....* ..... ..... .......| ADND | | |
| #61 |.**** ..*** **... ......*| SPDC1 | | |
| #62 |.**** ..*** **... ......*| SPDC2 | | |
| #80 |*...* ..**. ..... .......| BROADCST | | |
| #81 |*...* ..**. ..... .......| SPKRCALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #8378 |..... ..... ....* .......| HWTEST | | |
| #91 |....* ..... ....* .......| CFWVABTH | | |
| #92 |....* ..... ....* .......| CFWVAEXT | | |
| #93 |....* ..... ....* .......| CFWVAINT | | |
| #94 |....* ..... ....* .......| CFWVB | | |
| #95 |....* ..... ....* .......| CFWVBNA | | |
| #96 |....* ..... ....* .......| CFWVNA | | |
| #*056 |....* ..... *.... .......| DATA56 | | |
| #*1 |***** ..**. ..... .......| MWACT | | |
| #*2 |*...* ..**. ..... .......| BUZZ | | |
| #*329 |.**.* *.*** **... .......| FAX | R | |
| #*4 |*...* ..**. ..... .......| VCECALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*75 |....* ..... ..... .......| DIGIDAT | | |
| #*76 |....* *.**. ..*.* .......| SWITCH | | |
| #*77 |....* *.*** ***.* .......| DTE | | |
| #*78 |....* ..**. ....* .......| CODE | | |
| #*79 |....* ..**. ....* .......| SPEED | | |
| #*8 |***** ****. ..*** *****..| MWCANORI | | |
| #*90 |....* ..... ....* .......| HUNTPROG | | |
| #*92 |....* ..... ..... .......| AHTVCE | | |
| #*93 |....* ..... ..... .......| DHTVCE | | |
| #*94 |....* ..... ..... .......| AHTDTE | | |
| #*95 |....* ..... ..... .......| DHTDTE | | |
| #*96 |....* ..... ..... .......| AHTFAX | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*97 |....* ..... ..... .......| DHTFAX | | |
| #*99 |....* ..... ....* .......| HUNTCLR | | |
| ##0 |*...* ..**. ..... ......*| ACDAVLB | | |
| ##1 |....* ..... ..... .......| DCBK | | |
| ##2 |*...* ..**. ..... .......| PRIOFF | | |
| ##3 |....* ..... ....* .......| SPDIPROG | | |
| ##4 |*...* ..**. ..... ......*| LNR | | |
| ##5 |....* ..... ..... .......| DDND | | |
| ##7 |*.... ..... ..... .....*.| KNOVR | | |
| ##8 |***** ..**. ..... .......| DTA | | |
| ##91 |....* ..... ....* .......| CFWVAOFF | | |
| ##*78 |....* ..**. ....* .......| RESET | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| ###1 |*.... ...*. ..... .......| TRACE | | |
| ###20 |..... **..* **... .......| MILLWAT | | |
| ###21 |..... **..* **... .......| LOOPBACK | | |
| ###22 |..... **..* **... .......| SILENCE | | |
| ###23 |..... **..* **... .......| COMBO | | |
| ###4 |*.... ..... ..... .......| THRCONF | | |
| ###6 |....* ..... ..... .......| MONTONE | | |
--------------------------------------------------------------------------


AMO-DPLN -135 DIALING PLANS, FEATURE ACCESS CODES

DISPLAY COMPLETED;



Step 2. Add the new trunk board using BCSU.


<dis-bcsu

TYPE = tmd;

DIS-BCSU:TMD;
H500: AMO BCSU STARTED
---------------------------------------------------------------
| DETAILS OF TMD BOARD AT ADDRESS (LTG.LTU.SLOT) = 1. 2.103 |
| |
| CABTYP = 1 TIMTYP = SYST SIGTYP = MOS |
| FRAME = ESF TABS = NO FCTID = 2 |
| BI8SUB = YES BIVDET = NO |
|-------------------------------------------------------------|
| RDRATIO = 6 RDTH = 2500 RDQUAL = 15000 |
| YLSEND = 5000 YLTH = 400 YLQUAL = 100 |
| LOS = 150 AOS = 4000 |
| SESDISTH = 10 SESREQTH = 10 |
| OESDISTH = 30 OESDISIN = 24-00-00 |
| OESREQTH = 4 OESREQIN = 04-00-00 |
|-------------------------------------------------------------|
| NETUSR = NETWK ACKTIM = 1000 DLVTIM = 30000 |
| OCTMAX = 260 RETMAX = 3 WINDOW = 1 |
| CRIDC = TTSC = NSFIV = |
| NSFTSC = PFDGT = | |-------------------------------------------------------------|
| IGN = 0 IID = 1 |
---------------------------------------------------------------
AMO-BCSU -135 BOARD CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;

Step 3. Configure COT.


<dis-cot

COTNO = 0;

DIS-COT:0;
H500: AMO COT STARTED
|D|A|D|D|D|M|S|V|E|E|A|R|
|I|N|S|S|I|D|A|L|S|S|N|F|
|T|S|A|A|S|R|T|S|P|P|I|L|
| |R| |S| | | |A|A|D|D|A|
| | | | | | | |T|N|N|N|S|
| | | | | | | | |I|I|I|H|
COT | | | | | | | | | |S|S| |
----+-+-+-+-+-+-+-+-+-+-+-+-+
0 | | | | | | | | | | | | |
----+-+-+-+-+-+-+-+-+-+-+-+-+
AMO-COT -135 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;

Step 4. Configure Class of Parameter for device handler using COP.


<dis-cop

COPNO = 0;

DIS-COP:0;
H500: AMO COP STARTED
| | | | | |
| | S E A | | | |
| | T E S N | | | |
| | A S V S P I D |DD| S| |
| | D Z L P D D T |TT| U| P |
| | I A A S S A N N O |MM| P| D |
|COP| A N C A A N I I N |FF| V| P |
|IDX| L S K T T I S S E | L|12|1234|
+---+-------------------+--+--+----+
| 0| | | | |
+---+-------------------+--+--+----+
AMO-COP -135 CLASS OF PARAMETER
DISPLAY COMPLETED;

Step 5. Add the new trunk group access code using TGACC.



<dis-tgacc

TGRP = 40;

DIS-TGACC:40;
H500: AMO TGACC STARTED
+------------------------------------------------------------------------------+
| TGRP NUMBER : 40 TGRP NAME : T1PRI /N MAXIMUM NO: 23 |
| SUBGROUP NUMBER: 11 DEVICE TYPE: PRI B DIR TYPE : BOTH |
| ACD THRESHOLD : * TRACENO : 0 USAGE TYPE: TERR |
| ALLOCATED TO AT LEAST ONE ROUTE GDTR RULE : 0 |
| SELECTION : LOW CFBLOCK : DISABLED |
| THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 2-103- 1| 1- 2-103- 2| 1- 2-103- 3| 1- 2-103- 4| 1- 2-103- 5| 1- 2-103- 6|
+------------------------------------------------------------------------------+
| 1- 2-103- 7| 1- 2-103- 8| 1- 2-103- 9| 1- 2-103-10| 1- 2-103-11| 1- 2-103-12|
+------------------------------------------------------------------------------+
| 1- 2-103-13| 1- 2-103-14| 1- 2-103-15| 1- 2-103-16| 1- 2-103-17| 1- 2-103-18|
+------------------------------------------------------------------------------+
| 1- 2-103-19| 1- 2-103-20| 1- 2-103-21| 1- 2-103-22| 1- 2-103-23| - - - |
+------------------------------------------------------------------------------+
AMO-TGACC-135 TRUNK GROUP ACCESS CODE
DISPLAY COMPLETED;



Step 6. Add the channels using TCSU.

TCSU - B Channel
<dis-tcsu

PEN1 = 1-2-103-1;

DIS-TCSU:1-2-103-1;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103- 1 INS: Y BOARD: TMDN64P DEV: PRIB TGRP: 40 |
+------------------------------------------------------------------------+
| TRKID : 0040 TCCID : |
| CCT : /0040 |
| |
| ACDATA : 0 DITIDX : 0 LOCANA : |
| ATNTYP : ISDN DPLN : 0 REMANA : |
| COPNO : 0 ITR : 0 SIDANI : N |
| COSNO : 75 LCRCOSD : 5 SRTIDX : 3 |
| COTNO : 0 LCRCOSV : 5 TRTBL : DIDCR |
| DEDSVC : NONE FACILITY : * |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;

TCSU - D Channel
<dis-tcsu

PEN1 = 1-2-103-24;
DIS-TCSU:1-2-103-24;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103-24 INS: Y BOARD: TMDN64P DEV: PRID |
+------------------------------------------------------------------------+
| TCCID : |
| CCT : |
| |
| ACDATA : 0 DEDSCC : INTERFID : |
| COPNO : 0 DITIDX : ITR : 0 |
| COTNO : 0 DPLN : 0 PROTOCOL : NI2 |
| |
| TMR301 : 300 SEC. TMR308 : 4 SEC. TMR313 : 4 SEC. |
| TMR303 : 4 SEC. TMR309 : 90 SEC. TMR316 : 30 SEC. |
| TMR305 : 30 SEC. TMR310 : 30 SEC. TMR322 : 4 SEC. |
| TDELAY : 3000 MSEC. BEARER: ONE |
| NCT : N TNCT : |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;

Step 7. Configure LROUT.

<dis-lrout

ROUTE = 40;

DIS-LROUT:40;
H500: AMO LROUT STARTED
LCR ROUTE DEFINITION TABLE
--------------------------
-------------------------------------------------------------------------
|ROUTENUM = 40 SCHED A = X AORT = INFORMATION |
|ROUTEELE = 1 B = AUTH = 1 TRANS CAP = S3V |
|BEARER = ONE C = ONHKQ = Y TRKSIG = PRI |
|BANDWTH = 1 D = OFFHKQ = Y SCCID = |
|TRUNKGRP = 40 E = ODRNUM = 1 SVCVCE = NON |
|MASTGRP = 8 F = APLTYP = VD SVCN-V = NON |
|ROUTSERV = N G = FACNUM = |
| H = |
-------------------------------------------------------------------------
END OF LCR ROUTE DEFINITION TABLE DISPLAY
AMO-LROUT-135 ROUTE DEFINITION DETERMINATION PACKAGE
DISPLAY COMPLETED;

Step 8. Configure LODR.

<dis-lodr

RANGE =
DIS-LODR:;
H500: AMO LODR STARTED
<< DISPLAY LCR OUTDIAL RULE >>
ODR NO COMMAND BRANCH VALUE
------ ------- ------------
1 ECHOALL
END -------- END OF DISPLAY --------AMO-LODR -135 AMO LCR ODR FOR SWITCHING UNIT
DISPLAY COMPLETED;
<

Configuring the Cisco CallManager

Figure 1

Configuring the 6608-E1 Gateway

Route Pattern Configuration

Test Results

As shown in the diagram below, a Siemens Hicom 300 E CS PBX was connected via an ISDN T1 PRI link to a Cisco 6608-T1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-T1 and the PBX.

Test Configuration

Layer 1 (Physical Layer)

The Siemens configuration screen for the DS1 trunk interface is reached with the command:

<cha-bssu

Layers 2 & 3 (Q.921 and Q.931)

Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.

Layer 2 Q.921 packets were monitored to ensure that each PBX/6608-T1 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.

Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.

Telephone calls were made end-to-end in both directions through the Cisco 6608-T1 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.

User/Network Settings

The Cisco 6608-T1 Gateway with ISDN protocol type setting of PRI-NI2 supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.

The "Network/user" choice for the Siemens Hicom 300 E PBX is made by deactivating the B channels/D-channel (<dea-dssu) and the DS1 board (<dea-bssu) consecutively. A change command is then issued to the Board Configuration Switching Unit (BCSU) to get to the "network/user" prompt (<cha-bcsu). The DS1 board by (<act-bssu), the D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.

.

Table 1  PBX 1 - ETSI (Network) Cisco 6608-E1 Gateway - PRI EURO (User)

Siemens Hicom 330 E CS Switch-type/ Protocol side setting
Cisco 6608-E1 ISDN protocol-type/Protocol
side setting

NI2 / Master

PRI NI2 / User


Table 2  Basic Calls: (Enbloc Sending)

Calls Made
Call Comp?
"Calling Number" Passed to Final Destination?
"Calling Name" Passed to Final Destination?
"Called Number" Passed to Orig. Side?
"Called Name" Passed to Orig. Side?
Notes

Phone A to Phone C

Yes

Yes

No

No 1

No

2

Phone C to Phone A

Yes

Yes

No

Yes

No

3

1 CallManager is not sending "Connected Number" information in the connect message back to PBX.

2 The Siemens PRI interface with ETSI setting does not support "Calling Name" presentation Feature.

3 The display on the Siemens phone is oly active (Calling Number is displayed) for apporximately 4 seconds, thereafter the displays goes blank. This could be caused by a display timer feature that expires.


Table 3  Call Transfers: (Supervised Local Transfers)

Calls Made
Call Comp?
Orig. "Calling Number" displayed on Final Dest. phone?
Orig. "Calling Name" displayed on Final Dest. phone?
"Called Number" display on Orig. phone updated after transfer?
"Called Name" display on Orig. phone updated after transfer?
Notes

Phone C to Phone A Xfr to Phone B

Yes

Yes

No

No

No

 

Phone A to Phone C Xfr to Phone D

Yes

Yes

No

No

No

 

Table 4  Call Conferencing (Local)

Calls Made
Call Comp?
"Calling Number" Passed to remaining conferee when the conferencing phone drops out?
"Calling Name" displayed on remaining conferee when the conferencing phone drops out?
"Connected Number" updated on Orig. Caller phone display when a conferee drops out?
"Connected Name" updated on Orig. Caller phone display when a conferee drops out?
Notes
Phone C to Phone A,
Phone A conf Phone B

Yes

(A Drops out) Yes

(A Drops out) No

(A Drops out) No

(A Drops out) No

 
Phone C to Phone A,
Phone C conf Phone D

Yes

(C Drops out) No

(C Drops out) No

(D Drops out) No

(D Drops out) No

 
Phone A to Phone C,
Phone C conf Phone D

Yes

(C Drops out) No

(C Drops out) No

(C Drops out) No

(C Drops out) No

 
Phone A to Phone C,
Phone A conf Phone B

Yes

(A Drops out) No

(A Drops out) No

(B Drops out) No

(B Drops out) No

 

Table 5  Call Forward (Local)

Calls Made
Call Comp?
Original "Calling Number" Passed to Final Dest.?
Original "Calling Name" Passed to Final Dest.?
Forwarding "Called Number" Pased to Final Dest.?
Forwarding "Called Name" Displayed on Final Dest.?
Final dest. "Connected Number" updated at orig. side?
Final dest. "ConnectedName" updated at orig. side?
Notes
Phone C to Phone A fwd to Phone B

Yes

Yes

No

No

No

No

No

 
Phone A to Phone C fwd to Phone D

Yes

Yes

No

No

No

No

No

 

Test Setup 2

Setup was as follows:

PBX1 configured as NI2, emulates User

Cisco 6608-T1 Gateway configured as PRI NI2, emulates Network

.

Table 6  Switch and Gateway Settings

Siemens Hicom 330 E CS Switch-type/ Protocol side setting
Cisco 6608-T1 ISDN protocol-type/Protocol
side setting

NI2/User

PRI NI2 / Network


The test results are the same as in previous section . Refer to Tables 2 through 5 for details.

Appendix A

Call Manager Software Release:

Siemens Hicom 330 E CS Software release


-------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-09-18 11:40:46
-------------------------------------------------------------------------------
<dis-ansu

DIS-ANSU;
H500: AMO ANSU STARTED
APS TYPE | NAME | SP REFERENCE NO.
-------------+----------+------------------
SWU RES-CODE | S0-ET0SC | P30252B6500S00101
SWU AMO-CODE | B0-ET0BC | P30252B6500B00101 SWU RES-TEXT | S0-TTDSD | P30252B650DS00101
SYSTEM NUMBER | DB SUBSYSTEM NAME
------------------+------------------
00000000000095393 | DB_SUSY_ZDBCCDSF
00000000000095393 | DB_SUSY_ZDBCCDS0
00000000000095393 | DB_SUSY_ZDBCCDS1
00000000000095393 | DB_SUSY_ZDBCCDS2
00000000000095393 | DB_SUSY_ZDBCCDSB
00000000000095393 | DB_SUSY_ZDBCCDSC
AMO-ANSU -135 ENTERING THE SYSTEM NUMBERS INTO THE SWU DATABASE
DISPLAY COMPLETED;
<

Catalyst 6000 Switch Configuration


Console> (enable) sh version
WS-C6006 Software, Version NmpSW: 5.5(6a)
Copyright (c) 1995-2001 by Cisco Systems
NMP S/W compiled on Feb 23 2001, 10:23:18

System Bootstrap Version: 5.3(1)

Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172

Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0
Fw : 5.3(1)
Fw1: 5.4(2)
Sw : 5.5(6a)
Sw1: 5.5(6a)
WS-F6K-PFC SAD05020221 Hw : 1.1
3 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4
Fw : 5.4(2)
Sw : 5.5(6a)
WS-F6K-VPWR Hw : 1.0
4 24 WS-X6624-FXS SAD050203M8 Hw : 3.0
Fw : 5.4(2)
Sw : 5.5(6a)
HP : A00203010010; DSP : A003E031 (3.3.
32)
5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)
6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)

DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 65408K 37863K 27545K 16384K 11546K 4838K 512K 198K 314K

Uptime is 83 days, 2 hours, 34 minutes
Console> (enable)

______________________________________________________________________________


Console> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
4 4 24 FXS WS-X6624-FXS no ok
5 5 8 T1 WS-X6608-T1 no ok
6 6 8 E1 WS-X6608-E1 no ok

Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD05010NBK
3 SAD04420N7B
4 SAD050203M8
5 SAD04400EM0
6 SAD04380DW1

Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)
00-04-c0-f8-42-00 to 00-04-c0-f8-42-01
00-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff
3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)
4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)
5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)
6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)

Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.1
3 Inline Power Module WS-F6K-VPWR 1.0
Console> (enable)
______________________________________________________________________________

Console> (enable) sh port 5
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
5/1 notconnect 1 full 1.544 T1
5/2 connected 1 full 1.544 T1
5/3 notconnect 1 full 1.544 T1
5/4 notconnect 1 full 1.544 T1
5/5 notconnect 1 full 1.544 T1
5/6 notconnect 1 full 1.544 T1
5/7 notconnect 1 full 1.544 T1
5/8 notconnect 1 full 1.544 T1

Port DHCP MAC-Address IP-Address Subnet-Mask
-------- ------- ----------------- --------------- ---------------
5/1 enable 00-01-c9-d9-3a-98 10.1.1.107 255.255.255.0
5/2 enable 00-01-c9-d9-3a-99 10.1.1.108 255.255.255.0
5/3 enable 00-01-c9-d9-3a-9a 10.1.1.109 255.255.255.0
5/4 enable 00-01-c9-d9-3a-9b 10.1.1.110 255.255.255.0
5/5 enable 00-01-c9-d9-3a-9c 10.1.1.111 255.255.255.0
5/6 enable 00-01-c9-d9-3a-9d 10.1.1.112 255.255.255.0
5/7 enable 00-01-c9-d9-3a-9e 10.1.1.113 255.255.255.0
5/8 enable 00-01-c9-d9-3a-9f 10.1.1.114 255.255.255.0

Port Call-Manager(s) DHCP-Server TFTP-Server Gateway
-------- ----------------- --------------- --------------- ---------------
5/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
5/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7

Port DNS-Server(s) Domain
-------- ----------------- -------------------------------------------------
5/1 - -
5/2 - -
5/3 - -
5/4 - -
5/5 - -
5/6 - -
5/7 - -
5/8 - -

Port CallManagerState DSP-Type
-------- ---------------- --------
5/1 registered C549
5/2 registered C549
5/3 registered C549
5/4 registered C549
5/5 registered C549
5/6 registered C549
5/7 registered C549
5/8 registered C549

Port NoiseRegen NonLinearProcessing
----- ---------- -------------------
5/1 enabled enabled
5/2 enabled enabled
5/3 enabled enabled
5/4 enabled enabled
5/5 enabled enabled
5/6 enabled enabled
5/7 enabled enabled
5/8 enabled enabled
Console> (enable)


hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Sep 6 13:02:52 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.