Use the trunk card group to configure individual ports on a trunk card. You can configure the following cards:
The trunk card table contains a list of the trunk cards available. You can add, delete, configure, and modify trunk cards. The objects within the trunk card table identify the different attributes on that particular card. For further information on trunk cards, refer to the Cisco VCO/4K Card Technical Descriptions.
{tc 1}
Description
A list of the trunk cards.
Object Identifier
1.3.6.1.4.1.886.1.3.1
Data Type
Sequence of TcEntry
Access Policy
Not accessible
Status
Mandatory
{tcTable 1}
Description
Each entry corresponds to a trunk card in the system.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1
Data Type
TcEntry
Access Policy
Not accessible
Status
Mandatory
Index
{tcIndex, tcType}
Sequence
tcIndex | CardIndex |
tcRack | Integer |
tcLevel | Integer |
tcSlot | Integer |
tcStatus | Integer |
tcUnusedPorts | Integer |
tcType | Integer |
tcRevVer | DisplayString |
tcPhyAdd | Integer |
tcNfasGrpIndex | Integer |
tcNfasGrpPosition | Integer |
tcAlarm | Integer |
tcErrorStatus | Integer |
tcOwnerString | OwnerString |
tcEntryStatus | EntryStatus |
{tcEntry 1}
Description
Identifies an object in the trunk card table and contains the physical location (hardware address) of the trunk card. The entry lists the rack (R), level (L), and slot (S) where the card resides. The tcIndex is the primary index into the trunk card table. See the "Card Index" section to determine the index value.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.1
Data Type
CardIndex
Access Policy
Read only
Status
Mandatory
{tcEntry 2}
Description
Rack (R) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.2
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 3}
Description
Level (L) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.3
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 4}
Description
Slot (S) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.4
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 5}
Description
Current status of the card.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.5
Data Type
Integer. The possible values and their meanings are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | active | Ports on this card can be involved in active calls and can be allocated to new calls. |
2 | maintenance | One or more ports on this card might be involved in active calls. No ports are allocated to new calls. |
3 | diagnostics | No ports on this card are involved in calls or allocated to new calls. |
4 | outOfService | No ports on this card can be involved in active calls. No ports are allocated to new calls. |
6 | campedOn | Status change to diagnostics mode was attempted while ports on this card were still involved in calls. No ports are allocated to new calls and card remains in this mode until further administrator action. |
Access Policy
Read-write
Status
Mandatory
{tcEntry 6}
Description
Number of ports not currently active on this card. For multispan cards, this entry indicates the number of ports not currently active on individual spans. Valid only for network interface and internal service circuit ports.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.6
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 7}
Description
Indicates the type of trunk card. The tcType object is the secondary index in the truck card table.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.7
Data Type
Integer. The valid card values and names are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | t1 | T1 Card |
2 | e1 | E1 Card |
3 | utc | Universal Trunk Card |
4 | did | Direct Inward Dial Card |
5 | e-m | E and M Card |
Access Policy
Read only
Status
Mandatory
{tcEntry 8}
Description
Version and revision numbers for the firmware installed on this card. Use this object to verify the firmware versions that you installed for network interface and service circuit cards are at the current level.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.8
Data Type
DisplayString. Length of the display string is from 1 to 5 characters.
Access Policy
Read only
Status
Mandatory
{tcEntry 9}
Description
Physical address of this card. The address is assigned by the system.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.9
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 10}
Description
A foreign key in the NFAS group table. Indicates to which NFAS group this card belongs.
To change this attribute, set the tcEntryStatus and the nfasGroup Table to underModification (3).
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.10
Data Type
Integer
Access Policy
Read-write
Status
Mandatory
{tcEntry 11}
Description
Specifies the position of the port in the assigned resource group.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.11
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 12}
Description
Tracks which alarms (internally represented as a bit map) are active on this card. A bit is set to 1 for each active card alarm (there are a total of 32 bits). The following table shows the bits and the alarm description:
.
Bit | Alarm Description |
---|---|
0 | Card failure - minor |
1 | Port failure - minor |
2 | T1/PRI carrier failure - major |
3 | T1/PRI remote carrier failure - major |
4 | T1/PRI card failure - major |
5 | T1 Signaling Bit - minor |
6 | PRI Bipolar Violations Mlimit reached |
7 | T1/PRI Out of Frame MLimit reached - minor |
8 | T1 Slip Maint Limit reached - minor |
9 | T1/PRI OOF condition - minor |
10 | PRI D-channel failure - major |
11-32 | Unsigned filler (set to zero) |
Note The NMS application needs to interpret the alarm status from the integer value returned by this object. |
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.12
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 13}
Description
Registers the last error that occurred on this card. For a list of card error messages, see "Card Error Messages".
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.13
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcEntry 14}
Description
The entity that configured this object and is therefore using the resources assigned to it.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.14
Data Type
OwnerString
Access Policy
Read-write
Status
Mandatory
{tcEntry 15}
Description
Status of this trunk card object.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.15
Data Type
EntryStatus
Access Policy
Read-write
Status
Mandatory
{tcEntry 16}
Description
Version/revision of the card download file.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.16
Data Type
DisplayString (size 1...4)
Access Policy
Read-only
Status
Mandatory
{tcEntry 17}
Description
Version/revision of the card download file.
Object Identifier
1.3.6.1.4.1.886.1.3.1.1.17
Data Type
UpgradeState
Access Policy
Read-only
Status
Mandatory
{tc 2}
Description
The time, displayed in hundredths of a second, since the trunk card table (tcTable) was last modified. Helps NMS application developers determine the polling of the agent parameters.
Object Identifier
1.3.6.1.4.1.886.1.3.2
Data Type
TimeTicks
Access Policy
Read only
Status
Mandatory
Use the trunk port configuration section to assign a name, a hardware type, a default inpulse rule, and a class of service (COS) to individual ports on a trunk card.
{tc 4}
Description
A list of port entries on the trunk card.
Object Identifier
1.3.6.1.4.1.886.1.3.4
Data Type
Sequence of TcPortEntry
Access Policy
Not accessible
Status
Mandatory
{tcPortTable 1}
Description
Contains objects belonging to a particular port.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1
Data Type
TcPortEntry
Access Policy
Not accessible
Status
Mandatory
Index
{tcIndex, tcPortIndex}
Sequence
tcPortIndex | Integer |
tcPortState | Integer |
tcCardType | Integer |
tcPortName | DisplayString |
tcPortHwType | Integer |
tcPortCos | Integer |
tcPortMajorState | PortMajorState |
tcPortSuppState | PortSuppState |
tcPortAddress | Integer |
tcInpulseRuleIndex | Integer |
tcResGroupIndex | Integer |
tcResGroupPosition | Integer |
tcPortErrorStatus | Integer |
tcPortOwnerString | OwnerString |
tcPortEntryStatus | PortEntryStatus |
{tcPortEntry 1}
Description
Indicates the port number on the card. Trunk cards can have 8, 24, or 32 ports. This object is the primary index key into this table.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.1
Data Type
Integer. The valid values for this field are 8, 24, or 32.
Access Policy
Read only
Status
Mandatory
{tcPortEntry 2}
Description
Contains the state of the port. The states are active (1) or inactive (2).
Note Always modify the state of ports one at a time. That is, the EntryStatus object must be set to valid after every SNMP_SET command on this object. |
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.2
Data Type
Integer. The two values are 1 (active) and 2 (inactive).
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 3}
Description
This object contains the type of trunk card to which the port is attached.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.3
Data Type
Integer. The valid cards and their names are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | t1 | T1 Card |
2 | e1 | E1 Card |
3 | utc | Universal Trunk Card |
4 | did | Direct Inward Dial Card |
5 | e-m | E and M Card |
Access Policy
Read only
Status
Mandatory
{tcPortEntry 4}
Description
Identifies individual circuits (optional database object). When using a port name, each one should be unique and describe what you use the port for.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.4
Data Type
DisplayString. This field accepts up to 8 upper- or lowercase alphanumeric characters.
Access Policy
Read-write
Status
Optional
{tcPortEntry 5}
Description
Determines the type of trunk interface circuit used for this port. Not all trunk card types require an entry for this field.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.5
Data Type
Integer. The following table shows valid combinations of card type and hardware type:
Value | String | Hardware Type
| ||||
T1 | UTC Outgoing | UTC Incoming | DID | E+M | ||
0 | none | N/A | N/A | N/A | N/A | N/A |
1 | gs | No | Yes | None1 | None | None |
2 | ls | No | Yes | None | None | None |
3 | em2w | No | No | None | None | None |
4 | em4w | Yes | No | None | None | None |
1No hardware type necessary. |
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 6}
Description
Determines the software operating characteristics for this port. Ports on the same card can have different class of service (COS) values.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.6
Data Type
Integer. The possible values and their meanings are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | o | OriginatingCalls originating from the system. Outgoing calls are initiated by the host command. |
2 | t | TerminatingCalls terminating at the system. Incoming calls are initiated by action outside the VCO or forced by the host command. |
3 | w2 | Two-WayCalls originating from the system or calls terminating at the system. Outgoing calls are initiated by the host command. Incoming calls are initiated by outside actions. |
4 | oa | Always Off Hook and OriginatingCalls originating from the system. Port goes off hook at system reset and remains off hook. Outgoing calls are initiated by the host command. |
5 | ta | Always Off Hook and TerminatingCalls terminating at the VCO. Port goes off hook at VCO system reset and remains off hook. Incoming calls are initiated by outside actions or forced by the host command. |
6 | a2 | Always Off Hook and Two-WayCalls originating from the VCO or calls terminating at the VCO. Port goes off hook at VCO system reset and remains off hook. Outgoing calls are initiated by the host command, incoming calls are initiated by outside actions or forced by the host command. |
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 7}
Description
The major state of the port.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.7
Data Type
PortMajorState
Access Policy
Read only
Status
Mandatory
{tcPortEntry 8}
Description
The supplementary state of the port.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.8
Data Type
PortSuppState
Access Policy
Read only
Status
Mandatory
{tcPortEntry 9}
Description
Specifies the software address (hexadecimal identifier) of the port for which data is displayed. The port can also be specified by the hardware address.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.9
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcPortEntry 10}
Description
A foreign key corresponding to the inpulseRuleIndex (ID 1.3.6.1.4.1.886.1.9.5.1.1) in the inpulseTable. Access this object while you are assigning a particular inpulse rule to a port.
This object determines the inpulse rule processed when the port goes off hook. Default inpulse rules are used for incoming ports only (Class of Service = T, W2, AT, or A2). The inpulse rule chosen must be defined at the control console using the inpulse rules Table screens or by using the inpulse rule table objects.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.10
Data Type
Integer. Possible values for this field are 0 to 30 in 2K mode, or 0 to 255 in 4K mode. Zero means you are not selecting a default inpulse rule.
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 11}
Description
A foreign key corresponding to the resGroupIndex in the resGroupTable. This index indicates the number of the resource group to which this port belongs. If no resource group is assigned, the value in this object is zero (0).
To change this attribute, set the tcEntryStatus and the resGroup Table objects to underModification (3).
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.11
Data Type
Integer. Possible values for this field are from 0 to 63 in 2K mode, or 0 to 224 in 4K mode.
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 12}
Description
Specifies the position of the port in the assigned resource group.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.12
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcPortEntry 13}
Description
Registers the last error that occurred on this port.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.13
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{tcPortEntry 14}
Description
The entity that configured this object and is therefore using the resources assigned to it.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.14
Data Type
OwnerString
Access Policy
Read-write
Status
Mandatory
{tcPortEntry 15}
Description
The status of the table entry.
Object Identifier
1.3.6.1.4.1.886.1.3.4.1.15
Data Type
PortEntryStatus
Access Policy
Read-write
Status
Mandatory
{tc 5}
Description
The time, displayed in hundredths of a second, since the tcPortTable was last modified. Helps NMS application developers determine the polling of the agent parameters.
Object Identifier
1.3.6.1.4.1.886.1.3.5
Data Type
TimeTicks
Access Policy
Read only
Status
Mandatory
Posted: Sat Sep 28 11:08:29 PDT 2002