Table A-1 shows the object identifiers for the respective ErrorStatus objects.
Object Name | Object Identifier |
---|---|
lcErrorStatus | 1.3.6.1.4.1.886.1.2.1.1.11 |
tcErrorStatus | 1.3.6.1.4.1.886.1.3.1.1.13 |
ptcErrorStatus | 1.3.6.1.4.1.886.1.4.1.1.27 |
isdnErrorStatus | 1.3.6.1.4.1.886.1.5.1.1.42 |
nbcErrorStatus | 1.3.6.1.4.1.886.1.6.4.1.10 |
dtgCardErrorStatus | 1.3.6.1.4.1.886.1.7.1.1.11 |
rcErrorStatus | 1.3.6.1.4.1.886.1.7.6.1.11 |
Table A-2 shows the meanings for the error message values.
Value | Message |
---|---|
256 | Invalid Operation Specified |
257 | Card Already Exists |
260 | Invalid Port |
262 | NBC and BRC Do Not Have Ports |
263 | NBC in 1-1-1 for A-side 1-1-2 for B side |
264 | Cannot Add NBC in Non-redundant System |
265 | Only NBC In This Slot |
266 | Only BRC In Slot One of Expansion Rack |
267 | ISDN Not Installed |
268 | No Available Port Memory |
269 | BRC Cannot Be Added to 1-1-1 |
270 | Invalid BRC Rack Level Slot Position |
272 | Invalid Card Type |
273 | Cannot Be Put Into Diagnostic |
274 | Card Does Not Support Remote Loopback |
275 | Cannot Be Put Into Maintenance |
276 | This Card Is Not Out Of Service |
277 | Card Must Be Active, Diag or Campon |
278 | Invalid Status Change Request |
280 | Can't Change Status of NBC |
282 | Card Already Active |
283 | Download In Progress On This Card |
284 | An Alarm Exists On This Card |
285 | No Standby DTG, Cannot Change State |
286 | Ports ActivePut in Campon |
287 | Card Must Be Active, Maint Or Campon |
289 | Ports Still In Resource Group #1 |
290 | Ports Still ActiveLeft in Campon |
292 | No Standby BRC pair, Cannot Change State |
296 | No Available Card Memory |
299 | Card Does Not Support Payload Loopback |
305 | Span Must Be Active, Diag or Campon |
306 | Span Must Be Active, Maint or Campon |
308 | Exceeded Time-Slot Capacity |
309 | Standby Capacity is Zero |
310 | Invalid card location |
2560 | Invalid card status specified |
2561 | Card already in the status specified |
2562 | Code download in progress |
2563 | Alarms exist for the card |
2564 | No standby BRC card |
2565 | Only one dtg card exists in the system |
2566 | Card is in Out Of Service, Must be in Active or Maint, Diag |
2567 | Card must be in Active or Maintenance state |
1This number symbol (#) is replaced by the group number. |