17.1 REPT ALM <MOD2ALM>
Report Alarm (1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC12, VC3, VCG, VT1, VT2, WLEN)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports an alarm condition against a facility or a path.
See Table 27-1 for supported modifiers by platform.
CategoryFault
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM <MOD2ALM>
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],
[<OCRTM>],,:[<DESC>],[<AIDDET>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM 1GFC
"FAC-2-1:MJ,LOS,SA,08-01,14-25-59,,:\"LOSS OF SIGNAL\",OC12"
;Output Parameters
Table 17-1 REPT ALM <MOD2ALM> Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "ALL" section
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
SRVEFF
The effect on service caused by the standing alarm or condition
Parameter type is SERV_EFF—the effect of the alarm on service
•NSA
The condition is non-service affecting
•SA
The condition is service affecting
OCRDAT
Date. Optional
OCRTM
Time. Optional
DESC
Condition description. Optional
AIDDET
AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional
Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot
•AD-1B
Optical Add/Drop Multiplexed (OADM) 1 Band Filter
•AD-1C
Optical Add/Drop Multiplexed (OADM) 1 Channel Filter
•AD-2C
Optical Add/Drop Multiplexed (OADM) 2 Channels Filter
•AD-4B
Optical Add/Drop Multiplexed (OADM) 4 Bands Filter
•AD-4C
Optical Add/Drop Multiplexed (OADM) 4 Channels Filter
•AICI
The AICI card
•AIP
The Alarm Indicator Panel
•ALM-PWR
Alarm Power
•ASAP-4
ASAP Carrier card with four PIM slots
•BP
The Backplane of the NE
•CE-100T-8
8 port CE-100T card on ONS 15454 and ONS 15310-CL
•CRFT-TMG
Craft Timing
•DCC
The Data Communications Channel
•DMX-32
Optical De/Multiplexed (DMX) 32 Channels
•DS1-14
A 14 port interface card supporting DS1 facilities
•DS1N-14
A 14 port interface card supporting DS1 facilities
•DS3-12
A 12 port interface card supporting DS3 facilities
•DS3-3
A 3 port interface card supporting DS3 facilities
•DS3-EC1-48
High Density DS3/EC1 card supporting 48 ports
•DS3ATM-12
A 12 port interface card supporting DS3 ATM facilities
•DS3CR-12
Cost reduced DS3
•DS3E-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3N-12
A 12 port interface card supporting DS3 facilities
•DS3NE-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3XM-6
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
•E1000T-2
A 2 port interface card supporting 1000 Base T Ethernet facilities
•E100T-12
A 12 port interface card supporting 100 Base T Ethernet facilities
•E100T-4
A 4 port interface card supporting 100 Base T Ethernet facilities (ONS 15327)
•EC1-12
A 12 port interface card supporting EC1 facilities
•EC1N-12
A 12 port interface card supporting EC1 facilities
•FILLER_CARD
Smart Filler card (ONS 15600)
•FTA
The Fan Tray of the NE
•FTA1
The Fan Tray 1 of the NE
•FTA2
The Fan Tray 2 of the NE
•G1K-4
A four port G1000 card
•MD-4
Optical Multiplexer/Demultiplexer with 4 Channels
•MIC-28-3-A
ONS 15327 MIC card A
•MIC-28-3-B
ONS 15327 MIC card B
•MIC-EXT
ONS 15327 MIC card
•MIC-GEN
ONS 15327 MIC card
•ML-100T-8
8 port ML-100T card (ONS 15310-CL)
•MUX-32
Optical Multiplexed (MUX) 32 Channels
•MXP-2.5G-10G
10G (4 * 2.5G) Muxponder Card
•OC12
An interface card that supports one or more OC-12 (622Mbs) optical facilities
•OC12-327
OC12 card (ONS 15327)
•OC12-4
A four port OC12 card
•OC12-IR-1
An interface card that supports one intermediate-range OC-12 (622Mbs) optical facilities
•OC12-LR-1
An interface card that supports one long-range OC-12 (622Mbs) optical facilities
•OC12-SR-1
An interface card that supports one short-range OC-12 (622Mbs) optical facilities
•OC192_4
4 port OC-192 card (ONS 15600)
•OC192-LR-1
An interface card that supports one or more OC-192 optical facilities
•OC3
An interface card that supports multiple OC-3 (155Mbs) optical facilities
•OC3-327
ONS 15327 OC3 card
•OC3-IR-4
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
•OC3-SR-4
An interface card that supports four short range OC-3 (155Mbs) optical facilities
•OC3ATM-IR-6
An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers
•OC3IR-STM1SH-
1310-8An OC3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192
•OC3POS-SR-4
An interface card that supports four short range OC-3 (155Mbs) POS optical facilities
•OC48
An interface card that supports one or more OC-48 optical facilities
•OC48-327
ONS 15327 OC-48 card
•OC48-AS-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot
•OC48-ELR-1
An interface card that supports one short range OC-48 (2.5Gbs) optical facility
•OC48-IR-1
An interface card that supports one intermediate range OC-48 (10Gbs) optical facility
•OC48-LR-1
An interface card that supports one long range OC-48 (10Gbs) optical facility
•OC48-SR-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities
•OC-48_16
16 port OC48 card (ONS 15600)
•OPT-BST
Optical Booster Amplifier
•OPT-PRE
Optical Preamplifier
•OSC-CSM
Optical Service Channel (OSC) with Combiner/Separator Module (SCM)
•OSCM
Optical Service Channel (OSC) Module
•PIM-4
Pluggable interface module with 4 PPM slots
•PPM-1
Pluggable port module with 1 port SFP module
•SSXC
Cross connect card (ONS 15600)
•TCC
The Timing Communication and Control card
•TSC
Timing and synchronization controller card (ONS 15600)
•TXP-MR-10G
10G Multirate Transponder Card
•TXP-MR-2.5G
Multirate 2.5G Unprotected
•TXPP-MR-2.5G
Multirate 2.5G Protected
•XCVT
A Cross-Connect card
•XC10G
A Cross-Connect card
•XTC
ONS 15327 XTC card
•XTC-DS1-14
ONS 15327 XTC DS1-14 card
•XTC-DS1-28
ONS 15327 XTC DS1-28 card
•XTC-DS1-56
ONS 15327 XTC DS1-56 card
•XTC-DS3-3
ONS 15327 XTC DS3-3 card
17.2 REPT ALM BITS
Report Alarm Building Integrated Timing Supply
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports an alarm condition on a BITS facility.
CategorySynchronization
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM BITS
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM BITS
"BITS-1:MJ,SYNC,SA,08-01,14-25-59,,:\"LOSS OF TIMING\""
;Output Parameters
Table 17-2 REPT ALM BITS Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "BITS" section
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
OCRDAT
Date. Optional
OCRTM
Time. Optional
SRVEFF
The effect on service caused by the standing alarm or condition
Parameter type is SERV_EFF—the effect of the alarm on service
•NSA
The condition is non-service affecting
•SA
The condition is service affecting
DESC
Condition description. Optional
17.3 REPT ALM COM
Report Alarm Common
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports an alarm condition when an AID cannot be given, for example, a fan failure is reported using this message.
CategoryFault
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM COM
"[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM COM
"COM:MJ,FAN,NSA,08-01,14-25-59,,:\"FAN FAILURE\""
;Output Parameters
Table 17-3 REPT ALM COM Output Parameters
Parameter and Values DescriptionAID
Access identifier. Identifies the entity to which the command pertains. Indicates an alarm without AID. String. Optional
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
OCRDAT
Date. Optional
OCRTM
Time. Optional
SRVEFF
The effect on service caused by the standing alarm or condition
Parameter type is SERV_EFF—the effect of the alarm on service
•NSA
The condition is non-service affecting
•SA
The condition is service affecting
DESC
Condition description. Optional
17.4 REPT ALM ENV
Report Alarm Environment
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports a customer-defined condition on an environmental alarm input.
CategoryEnvironment
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM ENV
"<AID>:<NTFCNCDE>,<ALMTYPE>,[<OCRDAT>],[<OCRTM>],[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM ENV
"ENV-IN-1:MJ,OPENDR,08-01,14-25-59,\"OPEN DOOR\""
;Output Parameters
Table 17-4 REPT ALM ENV Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "ENV" section. Identifies an environmental input
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
ALMTYPE
Abbreviated code identifying the alarm
Parameter type is ENV_ALM—environmental alarm types
•AIRCOMPR
Air compressor failure
•AIRCOND
Air conditioning failure
•AIRDRYR
Air dryer failure
•BATDSCHRG
Battery discharging
•BATTERY
Battery failure
•CLFAN
Cooling fan failure
•CPMAJOR
Centralized power major failure
•CPMINOR
Centralized power minor failure
•ENGINE
Engine failure
•ENGOPRG
Engine operating
•ENGTRANS
Standby engine transfer
•EXPLGS
Explosive gas
•FIRDETR
Fire detector failure
•FIRE
Fire
•FLOOD
Flood
•FUELLEAK
Fuel leak
•FUSE
Fuse failure
•GASALARM
Explosive gas, toxic gas, ventilation fail or gas monitor fail
•HATCH
CEV hatch fail
•GEN
Generator failure
•HIAIR
High airflow
•HIHUM
High humidity
•HITEMP
High temperature
•HIWTR
High water
•INTRUDER
Intrusion
•LEVELCON
Level converter
•LVDADSL
Secondary ADSL low voltage disconnect
•LVDBYPAS
Low voltage disconnect bypass
•LWBATVG
Low battery voltage
•LWFUEL
Low fuel
•LWHUM
Low humidity
•LWPRES
Low cable pressure
•LWTEMP
Low temperature
•LWWTR
Low water
•MISC
Miscellaneous
•OPENDR
Open door
•POWER
Commercial power failure
•PUMP
Pump failure
•PWR-48
48V power supply failure
•PWR-139
-139V power converter
•PWR-190
-190V power converter
•PWRMJ
Power supply major
•PWRMN
Power supply minor
•RECT
Rectifier failure
•RECTHI
Rectifier high voltage
•RECTLO
Rectifier low voltage
•RINGGENMJ
Ringing generator major
•RINGGENMN
Ringing generator minor
•RTACADSL
AC or AC/rectifier power fail ADSL equipment
•RTACCRIT
AC or AC/rectifier power fail DCL equipment critical site
•RTACPWR
AC or AC/rectifier power fail DCL equipment
•RTACPWRENG
Commercial AC fail, site equipped with standby engine
•RTBAYPWR
AC power loss distributed power RT bay
•RTRVENG
Retrieve standby engine, commercial AC restored
•SMOKE
Smoke
•TEMP
High-low temperature
•TOXICGAS
Toxic gas
•TREPEATER
T-repeater shelf
•VENTN
Ventilation system failure
OCRDAT
Date. Optional
OCRTM
Time. Optional
DESC
Condition description. Optional
17.5 REPT ALM EQPT
Report Alarm Equipment
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports an alarm condition against an equipment unit or slot.
CategoryEquipment
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM EQPT
"<AID>:<NTFCNCDE>,<CONDITION>,<SRVEFF>,
[<OCRDAT>],[<OCRTM>],,:[<DESC>],[<AIDDET>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM EQPT
"SLOT-7:MJ,CONTR,NSA,08-01,14-25-59,,:\"CONTROLLER FAILURE\",TCC"
;Output Parameters
Table 17-5 REPT ALM EQPT Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
CONDITION
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
SRVEFF
The effect on service caused by the standing alarm or condition
Parameter type is SERV_EFF—the effect of the alarm on service
•NSA
The condition is non-service affecting
•SA
The condition is service affecting
OCRDAT
Date. Optional
OCRTM
Time. Optional
DESC
Condition description. Optional
AIDDET
AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional
Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot
•AD-1B
Optical Add/Drop Multiplexed (OADM) 1 Band Filter
•AD-1C
Optical Add/Drop Multiplexed (OADM) 1 Channel Filter
•AD-2C
Optical Add/Drop Multiplexed (OADM) 2 Channels Filter
•AD-4B
Optical Add/Drop Multiplexed (OADM) 4 Bands Filter
•AD-4C
Optical Add/Drop Multiplexed (OADM) 4 Channels Filter
•AICI
The AICI card
•AIP
The Alarm Indicator Panel
•ALM-PWR
Alarm Power
•ASAP-4
ASAP Carrier card with four PIM slots
•BP
The Backplane of the NE
•CE-100T-8
Eight port CE-100T card on ONS 15454 and ONS 15310-CL
•CRFT-TMG
Craft Timing
•DCC
The Data Communications Channel
•DMX-32
Optical De/Multiplexed (DMX) 32 Channels
•DS1-14
A 14 port interface card supporting DS1 facilities
•DS1N-14
A 14 port interface card supporting DS1 facilities
•DS3-12
A 12 port interface card supporting DS3 facilities
•DS3-3
A three port interface card supporting DS3 facilities
•DS3-EC1-48
High Density DS3/EC1 card supporting 48 ports
•DS3ATM-12
A 12 port interface card supporting DS3 ATM facilities
•DS3CR-12
Cost reduced DS3
•DS3E-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3N-12
A 12 port interface card supporting DS3 facilities
•DS3NE-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3XM-6
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
•E1000T-2
A two port interface card supporting 1000 BASE T Ethernet facilities
•E100T-12
A 12 port interface card supporting 100 BASE T Ethernet facilities
•E100T-4
A four port interface card supporting 100 BASE T Ethernet facilities
•EC1-12
A 12 port interface card supporting EC1 facilities
•EC1N-12
A 12 port interface card supporting EC1 facilities
•FILLER_CARD
Smart Filler card (ONS 15600)
•FTA
The fan tray of the NE
•FTA1
The fan tray 1 of the NE
•FTA2
The fan tray 2 of the NE
•G1K-4
A four port G1000 card
•MD-4
Optical Multiplexer/Demultiplexer with 4 Channels
•MIC-28-3-A
ONS 15327 MIC card A
•MIC-28-3-B
ONS 15327 MIC card B
•MIC-EXT
ONS 15327 MIC card
•MIC-GEN
ONS 15327 MIC card
•ML-100T-8
Eight port ML-100T card (ONS 15310-CL)
•MUX-32
Optical Multiplexed (MUX) 32 Channels
•MXP-2.5G-10G
10G (4 * 2.5G) Muxponder Card
•OC12
An interface card that supports one or more OC-12 (622Mbs) optical facilities
•OC12-327
ONS 15327 OC-12 card
•OC12-4
A four port OC-12 card
•OC12-IR-1
An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities
•OC12-LR-1
An interface card that supports one long range OC-12 (622Mbs) optical facilities
•OC12-SR-1
An interface card that supports one short range OC-12 (622Mbs) optical facilities
•OC192_4
4 port OC192 card (ONS 15600)
•OC192-LR-1
An interface card that supports one or more OC-192 optical facilities
•OC3
An interface card that supports multiple OC-3 (155Mbs) optical facilities
•OC3-327
ONS 15327 OC-3 card
•OC3-IR-4
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
•OC3-SR-4
An interface card that supports four short range OC-3 (155Mbs) optical facilities
•OC3ATM-IR-6
An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers
•OC3IR-STM1SH-
1310-8An OC-3 card which has eight ports over the lower speed slot of the ONS 15454 with XC10G/192
•OC3POS-SR-4
An interface card that supports four short range OC-3 (155Mbs) POS optical facilities
•OC48
An interface card that supports one or more OC-48 (10Gbs) optical facilities
•OC48-327
ONS 15327 OC48 card
•OC48-AS-1
An interface card that supports one short-range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot
•OC48-ELR-1
An interface card that supports one short-range OC-48 (2.5Gbs) optical facility
•OC48-IR-1
An interface card that supports one intermediate-range OC-48 (10Gbs) optical facility
•OC48-LR-1
An interface card that supports one long-range OC-48 (10Gbs) optical facility
•OC48-SR-1
An interface card that supports one short-range OC-48 (10Gbs) optical facilities
•OC-48_16
16 port OC-48 card (ONS 15600)
•OPT-BST
Optical Booster Amplifier
•OPT-PRE
Optical Preamplifier
•OSC-CSM
Optical Service Channel (OSC) with Combiner/Separator Module (SCM)
•OSCM
Optical Service Channel (OSC) Module
•PIM-4
Pluggable interface module with four PPM slots
•PPM-1
Pluggable port module with one port SFP module
•SSXC
Cross connect card (ONS 15600)
•TCC
The Timing Communication and Control card
•TSC
Timing and synchronization controller card (ONS 15600)
•TXP-MR-10G
10G Multirate Transponder Card
•TXP-MR-2.5G
Multirate 2.5G Unprotected
•TXPP-MR-2.5G
Multirate 2.5G Protected
•XCVT
A Cross-Connect card
•XC10G
A Cross-Connect card
•XTC
ONS 15327 XTC card
•XTC-DS1-14
ONS 15327 XTC DS1-14 card
•XTC-DS1-28
ONS 15327 XTC DS1-28 card
•XTC-DS1-56
ONS 15327 XTC DS1-56 card
•XTC-DS3-3
ONS 15327 XTC DS3-3 card
17.6 REPT ALM SECU
Report Alarm Security
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of an alarmed security event against the NE.
Based on TR-NWT-000835, the AID of the security alarm should be the Connection IDentifier (CID) which is not currently supported.
The COM or UID is an acceptable substitute for the AID.
Note The INTRUSION-PSWD condition is the only condition that is reported as a standing condition instead of a transient condition. It defaults to NA and is reported by the REPT EVT SECU message. However, it can be reprovisioned to be reported at a higher severity. If the severity of this alarm is higher than NA, it is reported by the REPT ALM SECU message.
CategorySecurity
SecuritySuperuser
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM SECU
"<AID>:<NOTIFCODE>,<SECUALMTYPE>"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SECU
"COM:CR,INTRUSION-PSWD"
;Output Parameters
17.7 REPT ALM SYNCN
Report Alarm Synchronization
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports an alarm condition against a synchronization reference.
CategorySynchronization
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT ALM SYNCN
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SYNCN
"SYNC-NE:MJ,MAN,SA,08-01,14-25-59,,:\"MANUAL SWITCH\","
;Output Parameters
Table 17-7 REPT ALM SYNCN Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition
NTFCNCDE
Two-letter notification code
Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message
•CL
The condition causing the alarm has cleared
•CR
A critical alarm
•MJ
A major alarm
•MN
A minor alarm
•NA
The condition is not alarmed
•NR
The alarm is not reported
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" or a list of conditions
SRVEFF
The effect on service caused by the standing alarm or condition
Parameter type is SERV_EFF—the effect of the alarm on service
•NSA
The condition is non-service affecting
•SA
The condition is service affecting
OCRDAT
Date. Optional
OCRTM
Time. Optional
DESC
Condition description. Optional
17.8 REPT DBCHG
Report Database Change Message
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports any changes on the NE that result from:
•TL1 provisioning commands or their GUI equivalents containing the verbs: ALW, DLT, ED, ENT, INH, INIT, OPR, RLS, SET, and SW (for example, DLT-EQPT, ENT-CRS-STS1)
•External event such as a board insertion
•When secondary state is changed from AINS state to any other state, no REPT DBCHG messages are generated
Note•The REPT DBCHG is turned off by default. To turn REPT DBCHG on, you must issue the ALW-MSG-DBCHG command.
•REPT DBCHG messages will be generated every time a roll is performed. A cross-connect delete and add REPT DBCHG message will not be sent every time a roll is performed; instead a REPT DBCHG message on the roll will be sent.
CategoryLog
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT DBCHG
"TIME=<TIME>,DATE=<DATE>,[SOURCE=<SOURCE>],[USERID=<USERID>],
DBCHGSEQ=<DBCHGSEQ>:<COMMAND>:[<AID>]:::[<PSTPSTQ>,],<SST>"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100 REPT DBCHG
"TIME=14-35-46,DATE=99-07-28,SOURCE=123,USERID=CISCO15,DBCHGSEQ=456:
ENT-CRS-VT1:VT1-4-1-2-6-4:::PST-PSTQ,SST"
;Output Parameters
17.9 REPT EVT <MOD2ALM>
Report Event (1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC12, VC3, VCG, VT1, VT2, WLEN)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of a non-alarmed event. Beginning with R5.0,
REPT EVT <MOD2ALM> can report the RMON-managed threshold crossing alarm.See Table 27-1 for supported modifiers by platform.
CategoryFault
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT <MOD2ALM>
"<AID>:<CONDTYPE>,[<CONDEFF>],,,[<LOCN>],,[<MONVAL>],[<THLEV>],
[<TMPER>]:[<DESC>],[<AIDDET>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT 1GFC
"FAC-5-1:WKSWPR,TC,,,FEND,,12,13,15-MIN:\"WORKING SWITCH TOPROTECTION\",
OC48"
;Output Parameters
Table 17-9 REPT EVT <MOD2ALM> Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "ALL" section
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 node, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
LOCN
Location associated with a particular command in reference to the entity identified by the AID
Parameter type is LOCATION—the location where the action is to take place
•FEND
Action occurs on the Far End of the facility
•NEND
Action occurs on the Near End of the facility
MONVAL
Monitored value. Value to which the register identified by MONTYPE will be initialized or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. Float. Optional
THLEV
Threshold level. Float. Optional
TMPER
Accumulation time period for performance counters. Optional
Parameter type is TMPER—accumulation time period for the performance management center
•1-DAY
Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.
•1-HR
Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.
•1-MIN
Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.
•15-MIN
Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.
•RAW-DATA
Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.
DESC
Condition description. Optional
AIDDET
AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional
Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot
•AD-1B
Optical Add/Drop Multiplexed (OADM) 1 Band Filter
•AD-1C
Optical Add/Drop Multiplexed (OADM) 1 Channel Filter
•AD-2C
Optical Add/Drop Multiplexed (OADM) 2 Channels Filter
•AD-4B
Optical Add/Drop Multiplexed (OADM) 4 Bands Filter
•AD-4C
Optical Add/Drop Multiplexed (OADM) 4 Channels Filter
•AICI
The AICI card
•AIP
The Alarm Indicator Panel
•ALM-PWR
Alarm Power
•ASAP-4
ASAP Carrier card with four PIM slots
•BP
The Backplane of the NE
•CE-100T-8
Eight port CE-100T card on ONS 15454 and ONS 15310-CL
•CRFT-TMG
Craft Timing
•DCC
The Data Communications Channel
•DMX-32
Optical De/Multiplexed (DMX) 32 Channels
•DS1-14
A 14 port interface card supporting DS1 facilities
•DS1N-14
A 14 port interface card supporting DS1 facilities
•DS3-12
A 12 port interface card supporting DS3 facilities
•DS3-3
A three port interface card supporting DS3 facilities
•DS3-EC1-48
High Density DS3/EC1 card supporting 48 ports
•DS3ATM-12
A 12 port interface card supporting DS3 ATM facilities
•DS3CR-12
Cost reduced DS3
•DS3E-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3N-12
A 12 port interface card supporting DS3 facilities
•DS3NE-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3XM-6
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
•E1000T-2
A two port interface card supporting 1000 BASE T Ethernet facilities
•E100T-12
A 12 port interface card supporting 100 BASE T Ethernet facilities
•E100T-4
A four port interface card supporting 100 BASE T Ethernet facilities.
•EC1-12
A 12 port interface card supporting EC1 facilities
•EC1N-12
A 12 port interface card supporting EC1 facilities
•FILLER_CARD
Smart Filler card (ONS 15600)
•FTA
The fan tray of the NE
•FTA1
The fan tray 1 of the NE
•FTA2
The fan tray 2 of the NE
•G1K-4
A four port G1000 card
•MD-4
Optical Multiplexer/Demultiplexer with 4 Channels
•MIC-28-3-A
ONS 15327 MIC card A
•MIC-28-3-B
ONS 15327 MIC card B
•MIC-EXT
ONS 15327 MIC card
•MIC-GEN
ONS 15327 MIC card
•ML-100T-8
Eight port 100T card on ONS 15310-CL
•MUX-32
Optical Multiplexed (MUX) 32 Channels
•MXP-2.5G-10G
10G (4 * 2.5G) Muxponder Card
•OC12
An interface card that supports one or more OC-12 (622Mbps) optical facilities
•OC12-327
OC-12 card (ONS 15327)
•OC12-4
A four port OC12 card
•OC12-IR-1
An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities
•OC12-LR-1
An interface card that supports one long range OC-12 (622Mbps) optical facilities
•OC12-SR-1
An interface card that supports one short range OC-12 (622Mbps) optical facilities
•OC192_4
A four port OC192 card (ONS 15600)
•OC192-LR-1
An interface card that supports one or more OC-192 optical facilities
•OC3
An interface card that supports multiple OC-3 (155Mbps) optical facilities
•OC3-327
ONS 15327 OC-3 card
•OC3-IR-4
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
•OC3-SR-4
An interface card that supports four short range OC-3 (155Mbps) optical facilities
•OC3ATM-IR-6
An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers
•OC3IR-STM1SH-
1310-8An OC-3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192
•OC3POS-SR-4
An interface card that supports four short range OC-3 (155Mbps) POS optical facilities
•OC48
An interface card that supports one or more OC-48 (10Gbps) optical facilities
•OC48-327
OC-48 card (ONS 15327)
•OC48-AS-1
An interface card that supports one short range OC-48 (10Gbps) optical facilities that can be provisioned in any I/O slot
•OC48-ELR-1
An interface card that supports one short range OC-48 (2.5Gbps) optical facility
•OC48-IR-1
An interface card that supports one intermediate range OC-48 (10Gbs) optical facility
•OC48-LR-1
An interface card that supports one long range OC-48 (10Gbs) optical facility
•OC48-SR-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities
•OC-48_16
16 port OC-48 card (ONS 15600)
•OPT-BST
Optical Booster Amplifier
•OPT-PRE
Optical Preamplifier
•OSC-CSM
Optical Service Channel (OSC) with Combiner/Separator Module (SCM)
•OSCM
Optical Service Channel (OSC) Module
•PIM-4
Pluggable interface module with four PPM slots
•PPM-1
Pluggable port module with 1 port SFP module
•SSXC
Cross connect card (ONS 15600)
•TCC
The Timing Communication and Control card
•TSC
Timing and synchronization controller card (ONS 15600)
•TXP-MR-10G
10G Multirate Transponder Card
•TXP-MR-2.5G
Multirate 2.5G Unprotected
•TXPP-MR-2.5G
Multirate 2.5G Protected
•XCVT
A Cross-Connect card
•XC10G
A Cross-Connect card
•XTC
ONS 15327 XTC card
•XTC-DS1-14
ONS 15327 XTC DS1-14 card
•XTC-DS1-28
ONS 15327 XTC DS1-28 card
•XTC-DS1-56
ONS 15327 XTC DS1-56 card
•XTC-DS3-3
ONS 15327 XTC DS3-3 card
17.10 REPT EVT BITS
Report Event Building Integrated Timing Supply
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports a non-alarmed event against a BITS facility.
CategorySynchronization
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
** ATAG REPT EVT BITS
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT ALM BITS
"BITS-1:SSM-STU,TC,,,,,,,:\"SYNCHRONIZED - TRACEABILITY UNKNOWN\""
;Output Parameters
Table 17-10 REPT EVT BITS Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "BITS" section
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 node, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
DESC
Condition description. Optional
17.11 REPT EVT COM
Report Event Common
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports a non-alarmed event against an NE when there is no AID associated with it.
CategoryFault
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT COM
"[<AID>]:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT COM
"COM:CLDRESTART,TC,,,,,,,:\"COLD RESTART\","
;Output Parameters
Table 17-11 REPT EVT COM Output Parameters
Parameter and Values DescriptionAID
Access identifier. Identifies the entity to which the command pertains. String. Optional
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
DESC
Condition description. Optional
17.12 REPT EVT ENV
Report Event Environment
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of a non-alarmed event against an environment alarm input.
CategoryEnvironment
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT ENV
"<AID>:<ALMTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT ENV
"ENV-IN-2:OPENDR,TC,,,,,,,:\"OPEN DOOR\""
;Output Parameters
Table 17-12 REPT EVT ENV Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "ENV" section. Identifies an environmental input
ALMTYPE
Abbreviated code identifying the alarm
Parameter type is ENV_ALM—environmental alarm types
•AIRCOMPR
Air compressor failure
•AIRCOND
Air conditioning failure
•AIRDRYR
Air dryer failure
•BATDSCHRG
Battery discharging
•BATTERY
Battery failure
•CLFAN
Cooling fan failure
•CPMAJOR
Centralized power major failure
•CPMINOR
Centralized power minor failure
•ENGINE
Engine failure
•ENGOPRG
Engine operating
•ENGTRANS
Standby engine transfer
•EXPLGS
Explosive gas
•FIRDETR
Fire detector failure
•FIRE
Fire
•FLOOD
Flood
•FUELLEAK
Fuel leak
•FUSE
Fuse failure
•GASALARM
Explosive gas, toxic gas, ventilation fail or gas monitor fail
•HATCH
CEV hatch fail
•GEN
Generator failure
•HIAIR
High airflow
•HIHUM
High humidity
•HITEMP
High temperature
•HIWTR
High water
•INTRUDER
Intrusion
•LEVELCON
Level converter
•LVDADSL
Secondary ADSL low voltage disconnect
•LVDBYPAS
Low voltage disconnect bypass
•LWBATVG
Low battery voltage
•LWFUEL
Low fuel
•LWHUM
Low humidity
•LWPRES
Low cable pressure
•LWTEMP
Low temperature
•LWWTR
Low water
•MISC
Miscellaneous
•OPENDR
Open door
•POWER
Commercial power failure
•PUMP
Pump failure
•PWR-48
48V power supply failure
•PWR-139
-139V power converter
•PWR-190
-190V power converter
•PWRMJ
Power supply major
•PWRMN
Power supply minor
•RECT
Rectifier failure
•RECTHI
Rectifier high voltage
•RECTLO
Rectifier low voltage
•RINGGENMJ
Ringing generator major
•RINGGENMN
Ringing generator minor
•RTACADSL
AC or AC/rectifier power fail ADSL equipment
•RTACCRIT
AC or AC/rectifier power fail DCL equipment critical site
•RTACPWR
AC or AC/rectifier power fail DCL equipment
•RTACPWRENG
Commercial AC fail, site equipped with standby engine
•RTBAYPWR
AC power loss distributed power RT bay
•RTRVENG
Retrieve standby engine, commercial AC restored
•SMOKE
Smoke
•TEMP
High-low temperature
•TOXICGAS
Toxic gas
•TREPEATER
T-repeater shelf
•VENTN
Ventilation system failure
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
DESC
Condition description. Optional
17.13 REPT EVT EQPT
Report Event Equipment
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of a non-alarmed event against an equipment unit or slot.
CategoryEquipment
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT EQPT
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT EQPT
"SLOT-7:PLUGIN,TC,,,,,,,:\"EQUIPMENT PLUG-IN\",TCC"
;Output Parameters
Table 17-13 REPT EVT EQPT Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
DESC
Condition description. Optional
AIDDET
AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional
Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot
•AD-1B
Optical Add/Drop Multiplexed (OADM) 1 Band Filter
•AD-1C
Optical Add/Drop Multiplexed (OADM) 1 Channel Filter
•AD-2C
Optical Add/Drop Multiplexed (OADM) 2 Channels Filter
•AD-4B
Optical Add/Drop Multiplexed (OADM) 4 Bands Filter
•AD-4C
Optical Add/Drop Multiplexed (OADM) 4 Channels Filter
•AICI
The AICI card
•AIP
The Alarm Indicator Panel
•ALM-PWR
Alarm Power
•ASAP-4
ASAP Carrier card with four PIM slots
•BP
The Backplane of the NE
•CE-100T-8
Eight port CE-100T card on ONS 15454 and ONS 15310-CL
•CRFT-TMG
Craft Timing
•DCC
The Data Communications Channel
•DMX-32
Optical De/Multiplexed (DMX) 32 Channels
•DS1-14
A 14 port interface card supporting DS1 facilities
•DS1N-14
A 14 port interface card supporting DS1 facilities
•DS3-12
A 12 port interface card supporting DS3 facilities
•DS3-3
A three port interface card supporting DS3 facilities
•DS3-EC1-48
High Density DS3/EC1 card supporting 48 ports
•DS3ATM-12
A 12 port interface card supporting DS3 ATM facilities
•DS3CR-12
Cost reduced DS3
•DS3E-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3N-12
A 12 port interface card supporting DS3 facilities
•DS3NE-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3XM-6
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
•E1000T-2
A two port interface card supporting 1000 Base T Ethernet facilities
•E100T-12
A 12 port interface card supporting 100 Base T Ethernet facilities
•E100T-4
A four port interface card supporting 100 Base T Ethernet facilities.
•EC1-12
A 12 port interface card supporting EC1 facilities
•EC1N-12
A 12 port interface card supporting EC1 facilities
•FILLER_CARD
Smart Filler card (ONS 15600)
•FTA
The fan tray of the NE
•FTA1
The fan tray 1 of the NE
•FTA2
The fan tray 2 of the NE
•G1K-4
A four port G1000 card
•MD-4
Optical Multiplexer/Demultiplexer with 4 Channels
•MIC-28-3-A
ONS 15327 MIC card A
•MIC-28-3-B
ONS 15327 MIC card B
•MIC-EXT
ONS 15327 MIC card
•MIC-GEN
ONS 15327 MIC card
•ML-100T-8
Eight port 100T card on ONS 15310-CL
•MUX-32
Optical Multiplexed (MUX) 32 Channels
•MXP-2.5G-10G
10G (4 * 2.5G) Muxponder Card
•OC12
An interface card that supports one or more OC-12 (622Mbs) optical facilities
•OC12-327
ONS 15327 OC-12 card
•OC12-4
A four port OC-12 card
•OC12-IR-1
An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities
•OC12-LR-1
An interface card that supports one long range OC-12 (622Mbs) optical facilities
•OC12-SR-1
An interface card that supports one short range OC-12 (622Mbs) optical facilities
•OC192_4
Four port OC192 card (ONS 15600)
•OC192-LR-1
An interface card that supports one or more OC-192 optical facilities
•OC3
An interface card that supports multiple OC-3 (155Mbs) optical facilities
•OC3-327
ONS 15327 OC-3 card
•OC3-IR-4
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
•OC3-SR-4
An interface card that supports four short range OC-3 (155Mbs) optical facilities
•OC3ATM-IR-6
An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers
•OC3IR-STM1SH-
1310-8An OC-3 card which has eight ports over the lower speed slot of the ONS 15454 with XC10G/192
•OC3POS-SR-4
An interface card that supports four short range OC-3 (155Mbs) POS optical facilities
•OC48
An interface card that supports one or more OC-48 (10Gbs) optical facilities
•OC48-327
ONS 15327 OC-48 card
•OC48-AS-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot
•OC48-ELR-1
An interface card that supports one short range OC-48 (2.5Gbs) optical facility
•OC48-IR-1
An interface card that supports one intermediate range OC-48 (10Gbs) optical facility
•OC48-LR-1
An interface card that supports one long range OC-48 (10Gbs) optical facility
•OC48-SR-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities
•OC-48_16
16 port OC48 card (ONS 15600)
•OPT-BST
Optical Booster Amplifier
•OPT-PRE
Optical Preamplifier
•OSC-CSM
Optical Service Channel (OSC) with Combiner/Separator Module (SCM)
•OSCM
Optical Service Channel (OSC) Module
•PIM-4
Pluggable interface module with 4 PPM slots
•PPM-1
Pluggable port module with 1 port SFP module
•SSXC
Cross connect card (ONS 15600)
•TCC
The Timing Communication and Control card
•TSC
Timing and synchronization controller card (ONS 15600)
•TXP-MR-10G
10G Multirate Transponder Card
•TXP-MR-2.5G
Multirate 2.5G Unprotected
•TXPP-MR-2.5G
Multirate 2.5G Protected
•XCVT
A Cross-Connect card
•XC10G
A Cross-Connect card
•XTC
ONS 15327 XTC card
•XTC-DS1-14
ONS 15327 XTC DS1-14 card
•XTC-DS1-28
ONS 15327 XTC DS1-28 card
•XTC-DS1-56
ONS 15327 XTC DS1-56 card
•XTC-DS3-3
ONS 15327 XTC DS3-3 card
17.14 REPT EVT FXFR
Report Event Software Download
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15310-CL
Reports the FTP software download status of the start, completion, and completed percentage.
Note The FXFR_RSLT is only sent when the FXFR_STATUS is COMPLD.
Note The BYTES_XFRD is only sent when the FXFR_STATUS is IP or COMPLD.
CategoryFile Transfer
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT FXFR
"<FILENAME>,<FXFR_STATUS>,[<FXFR_RSLT>],[<BYTES_XFRD>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT FXFR
"NEW.PKG,COMPLD,SUCCESS,21215147"
;Output Parameters
17.15 REPT EVT IOSCFG
Report Event Internet Operating System Configuration File
Usage Guidelines
Cisco ONS 15454
Reports the status of copying the Cisco IOS configuration file when the COPY-IOSCFG command is issued.
Note You can identify if this message is caused by a Cisco IOS config file downloading/uploading/merging by looking at the SRC and DEST field in the message. See the "COPY-IOSCFG" section for more details.
Note There is no success/failure in the message to indicate the success or failure of the merge process when merging the startup Cisco IOS config file to the running config file.
CategoryFile Transfer
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT IOSCFG
"<AID>:<SRC>,<DEST>,<STATUS>,[<RESULT>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT IOSCFG
"SLOT-1:STARTUP,IOS-CONFIG-FILE-IN-NETWORK,COMPLD,SUCCESS"
;Output Parameters
Table 17-15 REPT EVT IOSCFG Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "EQPT" section. Slot AID for the equipment
SRC
Source access identifier. Specifies where the Cisco IOS config file is copied from. String
DEST
Destination. Specifies where the Cisco IOS config file is copied to. String
STATUS
The status of COPY-IOSCFG: Start, IP, or COMPLD
Parameter type is TX_STATUS—status of the file transfer
•COMPLD
The file transmission is completed
•IP
The file transmission is in progress
•START
The file transmission is started
RESULT
The result of the file transfer: Success or Failure. Optional
Parameter type is TX_RSLT—result of the file transfer
•FAILURE
A failed result
•SUCCESS
A successful result
17.16 REPT EVT SECU
Report Event Security
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of a non-alarmed security event against the NE.
Based on TR-NWT-000835 in TR-NWT-000835 and the AID of the security alarm should be the Connection Identifier (CID) which is not supported in this release. The COM or UID is an acceptable substitute for the AID here. CIDs will be supported in a future release.
For the rule of single failure, single message/alarm, the security alarm will not be reported as
REPT ALM COM, because it is reported as REPT ALM SECU.Because the NE sends this security message as a transient message, to make all TL1 autonomous messages consistent, the TL1 agent reports the security message into REPT EVT SECU.
This message is inhibited by default. A superuser will have to issue the ALW-MSG-SECU to see this message.
CategorySecurity
SecuritySuperuser
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT SECU
"<AID>:<DNFIELD>,[<CONDEFF>],,,,,,,:<SECURITY>:<DNFIELD1>"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SECU
"COM:LOGIN-FAILURE-PSWD,TC,,,,,,,:\"SECURITY:
INVALID LOGIN - PASSWORD - SEE AUDIT LOG\""
;Output Parameters
17.17 REPT EVT SESSION
Report Event Session
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports a non-alarmed event related to establishing a session with the NE.
Note•The WARN field might contain different information depending on the type of session-related event.
•If the password aging feature has not been enabled (or the feature is enabled but the password is not close to expiring):
/*USER <UID> LOGGED IN <IP/SERIAL PORT*/
•If the forced password feature is enforced and the user is logging in for the first time (or the password has expired):
/*PLEASE CHANGE PASSWORD BEFORE CONTINUING*/
•If a session is terminated for any reason (except a user timeout), the reason for the session termination is indicated in the warning (<WARN>).
CategorySecurity
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT SESSION
"<AID>:<EXP>,<PCN>"
"<WARN>"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SESSION
"TCCP:YES,5-DAY"
"/* USER TERRI LOGGED IN TO TCCP */"
;Output Parameters
17.18 REPT EVT SYNCN
Report Event Synchronization
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the occurrence of a non-alarmed event against a synchronization entity.
CategorySynchronization
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT EVT SYNCN
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SYNCN
"SYNC-NE:SWTOINT,SC,,,,,,,:\"SWITCH TO INTERNAL CLOCK\",TCC"
;Output Parameters
Table 17-18 REPT EVT SYNCN Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition
CONDTYPE
Condition type for an alarm or a reported event
Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions
CONDEFF
The effect of the event on the condition of the NE
Parameter type is COND_EFF—the state of the condition upon the affected unit
•CL
Standing condition cleared
•SC
Standing condition raised
•TC
Transient condition
DESC
Condition description. Optional
AIDDET
AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional
Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot
•AD-1B
Optical Add/Drop Multiplexed (OADM) 1 Band Filter
•AD-1C
Optical Add/Drop Multiplexed (OADM) 1 Channel Filter
•AD-2C
Optical Add/Drop Multiplexed (OADM) 2 Channels Filter
•AD-4B
Optical Add/Drop Multiplexed (OADM) 4 Bands Filter
•AD-4C
Optical Add/Drop Multiplexed (OADM) 4 Channels Filter
•AICI
The AICI card
•AIP
The Alarm Indicator Panel
•ALM-PWR
Alarm Power
•ASAP-4
ASAP Carrier card with four PIM slots
•BP
The Backplane of the NE
•CE-100T-8
Eight port CE-100T card on ONS 15454 and ONS 15310-CL
•CRFT-TMG
Craft Timing
•DCC
The Data Communications Channel
•DMX-32
Optical De/Multiplexed (DMX) 32 Channels
•DS1-14
A 14 port interface card supporting DS1 facilities
•DS1N-14
A 14 port interface card supporting DS1 facilities
•DS3-12
A 12 port interface card supporting DS3 facilities
•DS3-3
A three port interface card supporting DS3 facilities
•DS3-EC1-48
High Density DS3/EC1 card supporting 48 ports
•DS3ATM-12
A 12 port interface card supporting DS3 ATM facilities
•DS3CR-12
Cost reduced DS-3
•DS3E-12
A 12 port DS-3 enhancement interface card supporting DS3E facilities
•DS3N-12
A 12 port interface card supporting DS-3 facilities
•DS3NE-12
A 12 port DS3 enhancement interface card supporting DS3E facilities
•DS3XM-6
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
•E1000T-2
A two port interface card supporting 1000 BASE T Ethernet facilities
•E100T-12
A 12 port interface card supporting 100 BASE T Ethernet facilities
•E100T-4
A four port interface card supporting 100 BASE T Ethernet facilities
•EC1-12
A 12 port interface card supporting EC1 facilities
•EC1N-12
A 12 port interface card supporting EC1 facilities
•FILLER_CARD
Smart Filler card (ONS 15600)
•FTA
The fan tray of the NE
•FTA1
The fan tray 1 of the NE
•FTA2
The fan tray 2 of the NE
•G1K-4
A four port G1000 card
•MD-4
Optical Multiplexer/Demultiplexer with 4 Channels
•MIC-28-3-A
ONS 15327 MIC card A
•MIC-28-3-B
ONS 15327 MIC card B
•MIC-EXT
ONS 15327 MIC card
•MIC-GEN
ONS 15327 MIC card
•ML-100T-8
Eight port ML-100T card on ONS 15310-CL
•MUX-32
Optical Multiplexed (MUX) 32 Channels
•MXP-2.5G-10G
10G (4 * 2.5G) Muxponder Card
•OC12
An interface card that supports one or more OC-12 (622Mbs) optical facilities
•OC12-327
ONS 15327 OC12 card
•OC12-4
A four port OC12 card
•OC12-IR-1
An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities
•OC12-LR-1
An interface card that supports one long range OC-12 (622Mbs) optical facilities
•OC12-SR-1
An interface card that supports one short range OC-12 (622Mbs) optical facilities
•OC192_4
Four port OC-192 card (ONS 15600)
•OC192-LR-1
An interface card that supports one or more OC-192 optical facilities
•OC3
An interface card that supports multiple OC-3 (155Mbs) optical facilities
•OC3-327
ONS 15327 OC-3 card
•OC3-IR-4
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
•OC3-SR-4
An interface card that supports four short range OC-3 (155Mbs) optical facilities
•OC3ATM-IR-6
An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers
•OC3IR-STM1SH-
1310-8An OC3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192
•OC3POS-SR-4
An interface card that supports four short range OC-3 (155Mbs) POS optical facilities
•OC48
An interface card that supports one or more OC-48 (10Gbs) optical facilities
•OC48-327
ONS 15327 OC-48 card
•OC48-AS-1
An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot
•OC48-ELR-1
An interface card that supports one short-range OC-48 (2.5Gbs) optical facility
•OC48-IR-1
An interface card that supports one intermediate-range OC-48 (10Gbs) optical facility
•OC48-LR-1
An interface card that supports one long-range OC-48 (10Gbs) optical facility
•OC48-SR-1
An interface card that supports one short-range OC-48 (10Gbs) optical facilities
•OC-48_16
16 port OC48 card (ONS 15600)
•OPT-BST
Optical Booster Amplifier
•OPT-PRE
Optical Preamplifier
•OSC-CSM
Optical Service Channel (OSC) with Combiner/Separator Module (SCM)
•OSCM
Optical Service Channel (OSC) Module
•PIM-4
Pluggable interface module with four PPM slots
•PPM-1
Pluggable port module with one port SFP module
•SSXC
Cross connect card (ONS 15600)
•TCC
The Timing Communication and Control card
•TSC
Timing and synchronization controller card (ONS 15600)
•TXP-MR-10G
10G Multirate Transponder Card
•TXP-MR-2.5G
Multirate 2.5G Unprotected
•TXPP-MR-2.5G
Multirate 2.5G Protected
•XCVT
A Cross-Connect card
•XC10G
A Cross-Connect card
•XTC
ONS 15327 XTC card
•XTC-DS1-14
ONS 15327 XTC DS1-14 card
•XTC-DS1-28
ONS 15327 XTC DS1-28 card
•XTC-DS1-56
ONS 15327 XTC DS1-56 card
•XTC-DS3-3
ONS 15327 XTC DS3-3 card
17.19 REPT PM <MOD2>
Report Performance Monitoring (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, VT2)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports autonomous monitoring statistics as a result of the schedule created by SCHED-PMREPT.
See Table 27-1 for supported modifiers by platform.
CategoryPerformance
SecurityRetrieve
Related Commands
Output FormatSID DATE TIME
A ATAG REPT PM <MOD2>
"<AID>:<MONTYPE>,<MONVAL>,<VLDTY>,<LOCN>,<DIRN>,<TMPER>,<MONDAT>,
<MONTM>"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100 REPT PM 10GFC
"FAC-3-1:CVL,10,PRTL,NEND,BTH,15-MIN,05-25,14-46"
;Output Parameters
Table 17-19 REPT PM <MOD2> Output Parameters
Parameter and Values DescriptionAID
Access identifier from the "ALL" section
MONTYPE
Monitored type
Parameter type is ALL_MONTYPE—monitoring type list
•AISSP
Alarm Indication Signal Seconds—Path
•ALL
All possible values
•BBE-PM
OTN—Background Block Errors—Path Monitor Point
•BBE-SM
OTN—Background Block Errors—Section Monitor Point
•BBER-PM
OTN—Background Block Error Ratio—Path Monitor Point expressed as 1/10th of a percentage.
•BBER-SM
OTN—Background Block Error Ratio—Section Monitor Point expressed as 1/10th of a percentage.
•BIEC
FEC—Bit Errors Corrected
•CGV
8B10B—Code Group Violations
•CSSP
Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)
•CVCPP
Coding Violations—CP-Bit Path
•CVL
Coding Violations—Line
•CVP
Coding Violations—Path
•CVS
Coding Violations—Section
•CVV
Coding Violations—Section
•DCG
8B10B—Data Code Groups
•ESAP
Errored Second Type A-Path (DS3XM-12 DS1 PM count)
•ESBP
Errored Second Type B-Path (DS3XM-12 DS1 PM count)
•ESCPP
Errored Seconds—CP—Bit Path
•ESL
Errored Seconds—Line
•ESNPFE
Errored Second -Network Path (DS3XM-12 DS1 PM count)
•ESP
Errored Seconds—Path
•ES-PM
OTN—Errored Seconds—Path Monitor Point
•ES-SM
OTN—Errored Seconds—Section Monitor Point
•ESR
Errored Second—Ratio
•ESR-PM
Errored Seconds Ratio—Path monitor Point expressed as 1/10th of a percentage
•ESR-SM
Errored Seconds Ratio—Section monitor Point expressed as 1/10th of a percentage
•ESS
Errored Seconds—Section
•ESV
Errored Seconds—VT Path
•etherStatsBroadcastPkts
The total number of good packets received that were directed to a multicast address
•etherStatsCollisions
Number of transmit packets that are collisions
•etherStatsCRCAlignErrors
The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets
•etherStatsDropEvents
Number of received frames dropped at the port level
•etherStatsFragments
The total number of packets received that were less than 64 octets
•etherStatsJabbers
The total number of packets received that are longer than 1518 octets
•etherStatsOctets
The total number of octets of data
•etherStatsOversizePkts
The total number of packets received that are longer than 1518 octets
•etherStatsPkts
The total number of packets (including bad packets, broadcast packets, and multicast packets) received
•etherStatsUndersizePkts
The total number of packets received that are less than 64 octets
•FCP
Failure Count—Line
•FC-PM
OTN—Failure Count—Path Monitor Point
•FC-SM
OTN—Failure Count—Section Monitor Point
•HP-AR
Availability Ratio
•HP-BBE
High-Order Path Background Block Error
•HP-BBER
High-Order Path Background Block Error Ratio
•HP-EB
High-Order Path Errored Block
•HP-ES
High-Order Path Errored Second
•HP-ESA
High-Order Path Errored Seconds - A
•HP-ESB
High-Order Path Errored Seconds - B
•HP-ESR
High-Order Path Errored Second Ratio
•HP-FC
High-Order Path Failure Count
•HP-NPJC-PDET
High-Order Path Negative Pointer Justification Count
•HP-NPJC-PGEN
High-Order Path, Negative Pointer Justification Count
•HP-OI
Outage Intensity
•HP-PJCDIFF
High-Order Path Pointer Justification Count Difference
•HP-PJCS-PDET
High-Order Path Pointer Justification Count
•HP-PJCS-PGEN
High-Order Path Pointer Justification Count Seconds
•HP-PPJC-PDET
High-Order Path Positive Pointer Justification Count
•HP-PPJC-PGEN
High-Order Path, Positive Pointer Justification Count
•HP-SEPI
The number of SEP events in available time
•HP-SES
High-Order Path Severely Errored Seconds
•HP-SESR
High-Order Path Severely Errored Second Ratio
•HP-UAS
High-Order Path Unavailable Seconds
•ifInBroadcastPkts
Number of broadcast packets received since the last counter reset
•ifInDiscards
The number of inbound packets
•ifInErrorBytePktss
Receive Error Byte
•ifInErrors
The number of inbound packets (or transmission units) that contained errors
•ifInFramingErrorPkts
Receive Framing Error
•ifInJunkInterPkts
Receive Interpkt Junk
•ifInMulticastPkts
Number of multicast packets received since the last counter reset
•ifInOctets
Number of bytes transmitted since the last counter reset
•ifInUcastPkts
Number of unicast packets received since the last counter reset
•ifOutBroadcastPkts
Number of broadcast packets transmitted
•ifOutDiscards
The number of outbound packets
•ifOutErrors
The number of outbound packets (or transmission units) that could not be transmitted because of errors
•ifOutMulticastPkts
Number of multicast packets transmitted
•ifOutPayloadCrcErrors
Received payload CRC errors
•ifOutUcastPkts
Number of unicast packets transmitted
•IOS
8B10B- Idle Ordered Sets
•IPC
Invalid Packet Count
•LBCL-AVG
Average Laser Bias current in uA
•LBCL-MAX
Maximum Laser Bias current in uA
•LBCL-MIN
Minimum Laser Bias current in uA
•LBCN
Normalized Laser Bias Current for OC3-8
•LBCN-HWT
Laser Bias Current
•LBCN-LWT
Laser Bias Current
•LOSSL
Loss of Signal Seconds—Line
•LP-BBE
Low-Order Path Background Block Error
•LP-BBER
Low-Order Path Background Block Error Ratio
•LP-EB
Low-Order Path Errored Block
•LP-ES
Low-Order Path Errored Second
•LP-ESA
Low-Order Path Errored Seconds-A
•LP-ESB
Low-Order Path Errored Seconds-B
•LP-ESR
Low-Order Path Errored Second Ratio
•LP-FC
Low-Order Path Failure Count
•LP-NPJC-DET
Low-Order Negative Pointer Justification Count, Detected
•LP-NPJC-GEN
Low Order Negative Pointer Justification Count, Generated
•LP-PPJC-DET
Low-Order Positive Pointer Justification Count, Detected
•LP-PPJC-GEN
Low-Order positive Pointer Justification Count, Generated
•LP-SEP
Low-Order Path Severely Errored Period
•LP-SEPI
Low-Order Path Severely Errored Period Intensity
•LP-SES
Low-Order Path Severely Errored
•LP-UAS
Low-Order Path Unavailable Seconds
•MS-PSC
Protection switch count
•MS-PSD
Protection switch duration
•NIOS
8B10B—Non Idle Ordered Sets
•NPJC-PDET
PPJC-PDET:Negative Pointer Justification
•NPJC-PGEN
PPJC-PGEN:Negative Pointer Justification
•OPR-AVG
Average Receive Power in 1/10 uW
•OPR-MAX
Maximum Receive Power in 1/10 uW
•OPR-MIN
Minimum Receive Power in 1/10 uW
•OPRN
Normalized Optical Receive Power for OC3-8
•OPRN-MAX
Maximum value for OPRN
•OPRN-MIN
Minimum value for OPRN
•OPT-AVG
Average Transmit Power in 1/10 uW
•OPT-MAX
Maximum Transmit Power in 1/10 uW
•OPT-MIN
Minimum Transmit Power in 1/10uW
•OPTN
Normalized value for Optical Power Transmitted for the OC3-8 card
•OPTN-MAX
Maximum value for OPTN
•OPTN-MIN
Minimum value for OPTN
•OPWR-AVG
Optical Power—Average Interval Value in 1/10th of dBm
•OPWR-MAX
Optical Power—Maximum Interval Value in 1/10th of dBm
•OPWR-MIN
Optical Power—Minimum Interval Value in 1/10th of dBm
•PPJC-PDET
PPJC-PDET:Positive Pointer Justification
•PPJC-PGEN
PPJC-PGEN:Positive Pointer Justification
•PSC
Protection Switching Count
•PSC-R
Protection Switching Count—Ring
•PSC-S
Protection Switching Count—Span
•PSC-W
Protection Switching Count—Working
•PSD
Protection Switching Duration
•PSD-R
Protection Switching Duration—Ring
•PSD-S
Protection Switching Duration—Span
•PSD-W
Protection Switching Duration—Working
•SASCPP
Severely Errored Framing/AIS Second—CP-Bit Path
•SASP
Severely Errored Framing/AIS Seconds Path
•SEFS
Severely Errored Framing Seconds
•SEFSP
Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)
•SESCPP
Severely Errored Second—CP-Bit Path
•SESL
Severely Errored Second—Line
•SESNPFE
Severely Errored Second - Network Path (DS3XM-12 DS1 PM count)
•SESP
Severely Errored Second—Path
•SES-PM
OTN—Severely Errored Second—Path
•SESR-PM
OTN—Severely Errored Second Ratio—Path Monitor Point expressed as 1/10th of a percentage
•SESR-SM
OTN—Severely Errored Second Ratio—Section Monitor Point expressed as 1/10th of a percentage
•SESS
Severely Errored Second—Section
•SES-SM
OTN—Severely Errored Second—Section Monitor Point
•SESV
Severely Errored Second—VT Path
•UASCPP
Unavailable Second—CP-Bit Path
•UASL
Unavailable Second—Line
•UASNPFE
Unavailable Second - Network Path (DS3XM-12 DS1 PM count)
•UASP
Unavailable Second—Path
•UAS-PM
OTN—Unavailable Second—Path Monitor Point
•UAS-SM
OTN—Unavailable Second—Section Monitor Point
•UASV
Unavailable Second—VT Path
•UNC-WORDS
FEC—Uncorrectable Words
•VPC
Valid Packet Count
MONVAL
The value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. String
VLDTY
Indicates whether the information for the specified time period was accumulated over the entire time period or a portion of that time period. Validity indicator for the reported PM data
Parameter type is VALIDITY—response validity
•COMPL
Complete response
•PRTL
Partial response
LOCN
Location associated with a particular command in reference to the entity identified by the AID
Parameter type is LOCATION—the location where the action is to take place
•FEND
Action occurs on the Far End of the facility
•NEND
Action occurs on the Near End of the facility
DIRN
Direction relative to the entity identified by the AID. Direction of PM relative to the entity identified by the AID
Parameter type is DIRECTION—transmit and receive directions
•BTH
Both transmit and receive directions
•RCV
Receive direction only
•TRMT
Transmit direction only
TMPER
Accumulation time period for performance counters
Parameter type is TMPER—accumulation time period for the performance management center
•1-DAY
Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available
•1-HR
Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available
•1-MIN
Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available
•15-MIN
Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length
•RAW-DATA
Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs
MONDAT
The beginning date of the PM or storage register period specified in TMPER. The format is MM-DD. String
MONTM
The beginning time of day of the PM or storage register period specified in TMPER. The format is HH-MM. String
17.20 REPT SW
Report Switch
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
Reports the autonomous switching of a unit in a duplex equipment pair to the standby state and its mate unit to the active state. An automatic report for the occurrence or clearance of an alarm or event that triggers the switch might be associated with the message.
CategoryProtection
SecurityRetrieve
Related Commands
ALW-SWDX-EQPT
ALW-SWTOPROTN-EQPT
ALW-SWTOWKG-EQPT
EX-SW-<OCN_BLSR>
INH-SWDX-EQPT
INH-SWTOPROTN-EQPT
INH-SWTOWKG-EQPT
SW-DX-EQPT
SW-TOPROTN-EQPT
SW-TOWKG-EQPT
Output FormatSID DATE TIME
A ATAG REPT SW
"<ACTID>,<STDBYID>"
;Output ExampleTID-000 1998-06-20 14:30:00
A 100.100 REPT SW
"SLOT-8,SLOT-10"
;Output Parameters
Table 17-20 REPT SW Output Parameters
Parameter and Values DescriptionACTID
Identifies the equipment unit from the "EQPT" section that was placed in the active state. Parameter grouping cannot be used with this parameter