cc/td/doc/product/ong/15400/r60docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

REPT Messages

17.1  REPT ALM <MOD2ALM>

17.2  REPT ALM BITS

17.3  REPT ALM COM

17.4  REPT ALM ENV

17.5  REPT ALM EQPT

17.6  REPT ALM SECU

17.7  REPT ALM SYNCN

17.8  REPT DBCHG

17.9  REPT EVT <MOD2ALM>

17.10  REPT EVT BITS

17.11  REPT EVT COM

17.12  REPT EVT ENV

17.13  REPT EVT EQPT

17.14  REPT EVT FXFR

17.15  REPT EVT IOSCFG

17.16  REPT EVT SECU

17.17  REPT EVT SESSION

17.18  REPT EVT SYNCN

17.19  REPT PM <MOD2>

17.20  REPT SW


REPT Messages


This chapter provides REPT (report) messages for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.

17.1  REPT ALM <MOD2ALM>

Report Alarm (1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC12, VC3, VCG, VT1, VT2, WLEN)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports an alarm condition against a facility or a path.

See Table 27-1 for supported modifiers by platform.

Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Output Format

SID DATE TIME
** ATAG REPT ALM <MOD2ALM>
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],
[<OCRTM>],,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM 1GFC
"FAC-2-1:MJ,LOS,SA,08-01,14-25-59,,:\"LOSS OF SIGNAL\",OC12"
;

Output Parameters

Table 17-1 REPT ALM <MOD2ALM> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "ALL" section

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

•NSA

The condition is non-service affecting

•SA

The condition is service affecting

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

Condition description. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional

Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot

•AD-1B

Optical Add/Drop Multiplexed (OADM) 1 Band Filter

•AD-1C

Optical Add/Drop Multiplexed (OADM) 1 Channel Filter

•AD-2C

Optical Add/Drop Multiplexed (OADM) 2 Channels Filter

•AD-4B

Optical Add/Drop Multiplexed (OADM) 4 Bands Filter

•AD-4C

Optical Add/Drop Multiplexed (OADM) 4 Channels Filter

•AICI

The AICI card

•AIP

The Alarm Indicator Panel

•ALM-PWR

Alarm Power

•ASAP-4

ASAP Carrier card with four PIM slots

•BP

The Backplane of the NE

•CE-100T-8

8 port CE-100T card on ONS 15454 and ONS 15310-CL

•CRFT-TMG

Craft Timing

•DCC

The Data Communications Channel

•DMX-32

Optical De/Multiplexed (DMX) 32 Channels

•DS1-14

A 14 port interface card supporting DS1 facilities

•DS1N-14

A 14 port interface card supporting DS1 facilities

•DS3-12

A 12 port interface card supporting DS3 facilities

•DS3-3

A 3 port interface card supporting DS3 facilities

•DS3-EC1-48

High Density DS3/EC1 card supporting 48 ports

•DS3ATM-12

A 12 port interface card supporting DS3 ATM facilities

•DS3CR-12

Cost reduced DS3

•DS3E-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3N-12

A 12 port interface card supporting DS3 facilities

•DS3NE-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

•E1000T-2

A 2 port interface card supporting 1000 Base T Ethernet facilities

•E100T-12

A 12 port interface card supporting 100 Base T Ethernet facilities

•E100T-4

A 4 port interface card supporting 100 Base T Ethernet facilities (ONS 15327)

•EC1-12

A 12 port interface card supporting EC1 facilities

•EC1N-12

A 12 port interface card supporting EC1 facilities

•FILLER_CARD

Smart Filler card (ONS 15600)

•FTA

The Fan Tray of the NE

•FTA1

The Fan Tray 1 of the NE

•FTA2

The Fan Tray 2 of the NE

•G1K-4

A four port G1000 card

•MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

•MIC-28-3-A

ONS 15327 MIC card A

•MIC-28-3-B

ONS 15327 MIC card B

•MIC-EXT

ONS 15327 MIC card

•MIC-GEN

ONS 15327 MIC card

•ML-100T-8

8 port ML-100T card (ONS 15310-CL)

•MUX-32

Optical Multiplexed (MUX) 32 Channels

•MXP-2.5G-10G

10G (4 * 2.5G) Muxponder Card

•OC12

An interface card that supports one or more OC-12 (622Mbs) optical facilities

•OC12-327

OC12 card (ONS 15327)

•OC12-4

A four port OC12 card

•OC12-IR-1

An interface card that supports one intermediate-range OC-12 (622Mbs) optical facilities

•OC12-LR-1

An interface card that supports one long-range OC-12 (622Mbs) optical facilities

•OC12-SR-1

An interface card that supports one short-range OC-12 (622Mbs) optical facilities

•OC192_4

4 port OC-192 card (ONS 15600)

•OC192-LR-1

An interface card that supports one or more OC-192 optical facilities

•OC3

An interface card that supports multiple OC-3 (155Mbs) optical facilities

•OC3-327

ONS 15327 OC3 card

•OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

•OC3-SR-4

An interface card that supports four short range OC-3 (155Mbs) optical facilities

•OC3ATM-IR-6

An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers

•OC3IR-STM1SH-
1310-8

An OC3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192

•OC3POS-SR-4

An interface card that supports four short range OC-3 (155Mbs) POS optical facilities

•OC48

An interface card that supports one or more OC-48 optical facilities

•OC48-327

ONS 15327 OC-48 card

•OC48-AS-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot

•OC48-ELR-1

An interface card that supports one short range OC-48 (2.5Gbs) optical facility

•OC48-IR-1

An interface card that supports one intermediate range OC-48 (10Gbs) optical facility

•OC48-LR-1

An interface card that supports one long range OC-48 (10Gbs) optical facility

•OC48-SR-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities

•OC-48_16

16 port OC48 card (ONS 15600)

•OPT-BST

Optical Booster Amplifier

•OPT-PRE

Optical Preamplifier

•OSC-CSM

Optical Service Channel (OSC) with Combiner/Separator Module (SCM)

•OSCM

Optical Service Channel (OSC) Module

•PIM-4

Pluggable interface module with 4 PPM slots

•PPM-1

Pluggable port module with 1 port SFP module

•SSXC

Cross connect card (ONS 15600)

•TCC

The Timing Communication and Control card

•TSC

Timing and synchronization controller card (ONS 15600)

•TXP-MR-10G

10G Multirate Transponder Card

•TXP-MR-2.5G

Multirate 2.5G Unprotected

•TXPP-MR-2.5G

Multirate 2.5G Protected

•XCVT

A Cross-Connect card

•XC10G

A Cross-Connect card

•XTC

ONS 15327 XTC card

•XTC-DS1-14

ONS 15327 XTC DS1-14 card

•XTC-DS1-28

ONS 15327 XTC DS1-28 card

•XTC-DS1-56

ONS 15327 XTC DS1-56 card

•XTC-DS3-3

ONS 15327 XTC DS3-3 card


17.2  REPT ALM BITS

Report Alarm Building Integrated Timing Supply

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports an alarm condition on a BITS facility.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Output Format

SID DATE TIME
** ATAG REPT ALM BITS
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM BITS
"BITS-1:MJ,SYNC,SA,08-01,14-25-59,,:\"LOSS OF TIMING\""
;

Output Parameters

Table 17-2 REPT ALM BITS Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "BITS" section

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

OCRDAT

Date. Optional

OCRTM

Time. Optional

SRVEFF

The effect on service caused by the standing alarm or condition

 

Parameter type is SERV_EFF—the effect of the alarm on service

•NSA

The condition is non-service affecting

•SA

The condition is service affecting

DESC

Condition description. Optional


17.3  REPT ALM COM

Report Alarm Common

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports an alarm condition when an AID cannot be given, for example, a fan failure is reported using this message.

Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Output Format

SID DATE TIME
** ATAG REPT ALM COM
"[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM COM
"COM:MJ,FAN,NSA,08-01,14-25-59,,:\"FAN FAILURE\""
;

Output Parameters

Table 17-3 REPT ALM COM Output Parameters 

Parameter and Values
Description

AID

Access identifier. Identifies the entity to which the command pertains. Indicates an alarm without AID. String. Optional

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

OCRDAT

Date. Optional

OCRTM

Time. Optional

SRVEFF

The effect on service caused by the standing alarm or condition

 

Parameter type is SERV_EFF—the effect of the alarm on service

•NSA

The condition is non-service affecting

•SA

The condition is service affecting

DESC

Condition description. Optional


17.4  REPT ALM ENV

Report Alarm Environment

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports a customer-defined condition on an environmental alarm input.

Category

Environment

Security

Retrieve

Related Commands

CLR-COND-SECU

OPR-ACO-ALL

OPR-EXT-CONT

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-EXT-CONT

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-ATTR-CONT

RTRV-ATTR-ENV

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-EXT-CONT

SET-ATTR-CONT

SET-ATTR-ENV

SET-ATTR-SECUDFLT


Output Format

SID DATE TIME
** ATAG REPT ALM ENV
"<AID>:<NTFCNCDE>,<ALMTYPE>,[<OCRDAT>],[<OCRTM>],[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM ENV
"ENV-IN-1:MJ,OPENDR,08-01,14-25-59,\"OPEN DOOR\""
;

Output Parameters

Table 17-4 REPT ALM ENV Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "ENV" section. Identifies an environmental input

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

ALMTYPE

Abbreviated code identifying the alarm

Parameter type is ENV_ALM—environmental alarm types

•AIRCOMPR

Air compressor failure

•AIRCOND

Air conditioning failure

•AIRDRYR

Air dryer failure

•BATDSCHRG

Battery discharging

•BATTERY

Battery failure

•CLFAN

Cooling fan failure

•CPMAJOR

Centralized power major failure

•CPMINOR

Centralized power minor failure

•ENGINE

Engine failure

•ENGOPRG

Engine operating

•ENGTRANS

Standby engine transfer

•EXPLGS

Explosive gas

•FIRDETR

Fire detector failure

•FIRE

Fire

•FLOOD

Flood

•FUELLEAK

Fuel leak

•FUSE

Fuse failure

•GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

•HATCH

CEV hatch fail

•GEN

Generator failure

•HIAIR

High airflow

•HIHUM

High humidity

•HITEMP

High temperature

•HIWTR

High water

•INTRUDER

Intrusion

•LEVELCON

Level converter

•LVDADSL

Secondary ADSL low voltage disconnect

•LVDBYPAS

Low voltage disconnect bypass

•LWBATVG

Low battery voltage

•LWFUEL

Low fuel

•LWHUM

Low humidity

•LWPRES

Low cable pressure

•LWTEMP

Low temperature

•LWWTR

Low water

•MISC

Miscellaneous

•OPENDR

Open door

•POWER

Commercial power failure

•PUMP

Pump failure

•PWR-48

48V power supply failure

•PWR-139

-139V power converter

•PWR-190

-190V power converter

•PWRMJ

Power supply major

•PWRMN

Power supply minor

•RECT

Rectifier failure

•RECTHI

Rectifier high voltage

•RECTLO

Rectifier low voltage

•RINGGENMJ

Ringing generator major

•RINGGENMN

Ringing generator minor

•RTACADSL

AC or AC/rectifier power fail ADSL equipment

•RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

•RTACPWR

AC or AC/rectifier power fail DCL equipment

•RTACPWRENG

Commercial AC fail, site equipped with standby engine

•RTBAYPWR

AC power loss distributed power RT bay

•RTRVENG

Retrieve standby engine, commercial AC restored

•SMOKE

Smoke

•TEMP

High-low temperature

•TOXICGAS

Toxic gas

•TREPEATER

T-repeater shelf

•VENTN

Ventilation system failure

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

Condition description. Optional


17.5  REPT ALM EQPT

Report Alarm Equipment

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports an alarm condition against an equipment unit or slot.

Category

Equipment

Security

Retrieve

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

CLR-COND-SECU

DLT-EQPT

ED-EQPT

ENT-EQPT

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

REPT RMV EQPT

REPT RST EQPT

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-ALMTH-EQPT

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-EQPT

SET-ALMTH-EQPT

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Output Format

SID DATE TIME
** ATAG REPT ALM EQPT
"<AID>:<NTFCNCDE>,<CONDITION>,<SRVEFF>,
[<OCRDAT>],[<OCRTM>],,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM EQPT
"SLOT-7:MJ,CONTR,NSA,08-01,14-25-59,,:\"CONTROLLER FAILURE\",TCC"
;

Output Parameters

Table 17-5 REPT ALM EQPT Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

CONDITION

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

•NSA

The condition is non-service affecting

•SA

The condition is service affecting

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

Condition description. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional

Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot

•AD-1B

Optical Add/Drop Multiplexed (OADM) 1 Band Filter

•AD-1C

Optical Add/Drop Multiplexed (OADM) 1 Channel Filter

•AD-2C

Optical Add/Drop Multiplexed (OADM) 2 Channels Filter

•AD-4B

Optical Add/Drop Multiplexed (OADM) 4 Bands Filter

•AD-4C

Optical Add/Drop Multiplexed (OADM) 4 Channels Filter

•AICI

The AICI card

•AIP

The Alarm Indicator Panel

•ALM-PWR

Alarm Power

•ASAP-4

ASAP Carrier card with four PIM slots

•BP

The Backplane of the NE

•CE-100T-8

Eight port CE-100T card on ONS 15454 and ONS 15310-CL

•CRFT-TMG

Craft Timing

•DCC

The Data Communications Channel

•DMX-32

Optical De/Multiplexed (DMX) 32 Channels

•DS1-14

A 14 port interface card supporting DS1 facilities

•DS1N-14

A 14 port interface card supporting DS1 facilities

•DS3-12

A 12 port interface card supporting DS3 facilities

•DS3-3

A three port interface card supporting DS3 facilities

•DS3-EC1-48

High Density DS3/EC1 card supporting 48 ports

•DS3ATM-12

A 12 port interface card supporting DS3 ATM facilities

•DS3CR-12

Cost reduced DS3

•DS3E-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3N-12

A 12 port interface card supporting DS3 facilities

•DS3NE-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

•E1000T-2

A two port interface card supporting 1000 BASE T Ethernet facilities

•E100T-12

A 12 port interface card supporting 100 BASE T Ethernet facilities

•E100T-4

A four port interface card supporting 100 BASE T Ethernet facilities

•EC1-12

A 12 port interface card supporting EC1 facilities

•EC1N-12

A 12 port interface card supporting EC1 facilities

•FILLER_CARD

Smart Filler card (ONS 15600)

•FTA

The fan tray of the NE

•FTA1

The fan tray 1 of the NE

•FTA2

The fan tray 2 of the NE

•G1K-4

A four port G1000 card

•MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

•MIC-28-3-A

ONS 15327 MIC card A

•MIC-28-3-B

ONS 15327 MIC card B

•MIC-EXT

ONS 15327 MIC card

•MIC-GEN

ONS 15327 MIC card

•ML-100T-8

Eight port ML-100T card (ONS 15310-CL)

•MUX-32

Optical Multiplexed (MUX) 32 Channels

•MXP-2.5G-10G

10G (4 * 2.5G) Muxponder Card

•OC12

An interface card that supports one or more OC-12 (622Mbs) optical facilities

•OC12-327

ONS 15327 OC-12 card

•OC12-4

A four port OC-12 card

•OC12-IR-1

An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities

•OC12-LR-1

An interface card that supports one long range OC-12 (622Mbs) optical facilities

•OC12-SR-1

An interface card that supports one short range OC-12 (622Mbs) optical facilities

•OC192_4

4 port OC192 card (ONS 15600)

•OC192-LR-1

An interface card that supports one or more OC-192 optical facilities

•OC3

An interface card that supports multiple OC-3 (155Mbs) optical facilities

•OC3-327

ONS 15327 OC-3 card

•OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

•OC3-SR-4

An interface card that supports four short range OC-3 (155Mbs) optical facilities

•OC3ATM-IR-6

An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers

•OC3IR-STM1SH-
1310-8

An OC-3 card which has eight ports over the lower speed slot of the ONS 15454 with XC10G/192

•OC3POS-SR-4

An interface card that supports four short range OC-3 (155Mbs) POS optical facilities

•OC48

An interface card that supports one or more OC-48 (10Gbs) optical facilities

•OC48-327

ONS 15327 OC48 card

•OC48-AS-1

An interface card that supports one short-range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot

•OC48-ELR-1

An interface card that supports one short-range OC-48 (2.5Gbs) optical facility

•OC48-IR-1

An interface card that supports one intermediate-range OC-48 (10Gbs) optical facility

•OC48-LR-1

An interface card that supports one long-range OC-48 (10Gbs) optical facility

•OC48-SR-1

An interface card that supports one short-range OC-48 (10Gbs) optical facilities

•OC-48_16

16 port OC-48 card (ONS 15600)

•OPT-BST

Optical Booster Amplifier

•OPT-PRE

Optical Preamplifier

•OSC-CSM

Optical Service Channel (OSC) with Combiner/Separator Module (SCM)

•OSCM

Optical Service Channel (OSC) Module

•PIM-4

Pluggable interface module with four PPM slots

•PPM-1

Pluggable port module with one port SFP module

•SSXC

Cross connect card (ONS 15600)

•TCC

The Timing Communication and Control card

•TSC

Timing and synchronization controller card (ONS 15600)

•TXP-MR-10G

10G Multirate Transponder Card

•TXP-MR-2.5G

Multirate 2.5G Unprotected

•TXPP-MR-2.5G

Multirate 2.5G Protected

•XCVT

A Cross-Connect card

•XC10G

A Cross-Connect card

•XTC

ONS 15327 XTC card

•XTC-DS1-14

ONS 15327 XTC DS1-14 card

•XTC-DS1-28

ONS 15327 XTC DS1-28 card

•XTC-DS1-56

ONS 15327 XTC DS1-56 card

•XTC-DS3-3

ONS 15327 XTC DS3-3 card


17.6  REPT ALM SECU

Report Alarm Security

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of an alarmed security event against the NE.

Based on TR-NWT-000835, the AID of the security alarm should be the Connection IDentifier (CID) which is not currently supported.

The COM or UID is an acceptable substitute for the AID.


Note The INTRUSION-PSWD condition is the only condition that is reported as a standing condition instead of a transient condition. It defaults to NA and is reported by the REPT EVT SECU message. However, it can be reprovisioned to be reported at a higher severity. If the severity of this alarm is higher than NA, it is reported by the REPT ALM SECU message.


Category

Security

Security

Superuser

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-CMD-SECU

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Output Format

SID DATE TIME
** ATAG REPT ALM SECU
"<AID>:<NOTIFCODE>,<SECUALMTYPE>"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SECU
"COM:CR,INTRUSION-PSWD"
;

Output Parameters

Table 17-6 REPT ALM SECU Output Parameters 

Parameter and Values
Description

AID

Access identifier. Identifies an entity with the condition. Defaults to COM. String

NOTIFCODE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

SECUALMTYPE

Security alarm type. It is a subset of the CONDITION type. In this release the only allowable type is INTRUSION-PSWD

Parameter type is SECUALMTYPE—security alarm type

•INTRUSION-PSWD

Condition raised after an invalid password is used during login. This condition is raised only if the password is used a specific number of times


17.7  REPT ALM SYNCN

Report Alarm Synchronization

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports an alarm condition against a synchronization reference.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Output Format

SID DATE TIME
** ATAG REPT ALM SYNCN
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SYNCN
"SYNC-NE:MJ,MAN,SA,08-01,14-25-59,,:\"MANUAL SWITCH\","
;

Output Parameters

Table 17-7 REPT ALM SYNCN Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

•CL

The condition causing the alarm has cleared

•CR

A critical alarm

•MJ

A major alarm

•MN

A minor alarm

•NA

The condition is not alarmed

•NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" or a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

•NSA

The condition is non-service affecting

•SA

The condition is service affecting

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

Condition description. Optional


17.8  REPT DBCHG

Report Database Change Message

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports any changes on the NE that result from:

•TL1 provisioning commands or their GUI equivalents containing the verbs: ALW, DLT, ED, ENT, INH, INIT, OPR, RLS, SET, and SW (for example, DLT-EQPT, ENT-CRS-STS1)

•External event such as a board insertion

•When secondary state is changed from AINS state to any other state, no REPT DBCHG messages are generated


Note•The REPT DBCHG is turned off by default. To turn REPT DBCHG on, you must issue the ALW-MSG-DBCHG command.

•REPT DBCHG messages will be generated every time a roll is performed. A cross-connect delete and add REPT DBCHG message will not be sent every time a roll is performed; instead a REPT DBCHG message on the roll will be sent.


Category

Log

Security

Retrieve

Related Commands

ALW-MSG-DBCHG

INH-MSG-DBCHG

RTRV-LOG


Output Format

SID DATE TIME
A ATAG REPT DBCHG
"TIME=<TIME>,DATE=<DATE>,[SOURCE=<SOURCE>],[USERID=<USERID>],
DBCHGSEQ=<DBCHGSEQ>:<COMMAND>:[<AID>]:::[<PSTPSTQ>,],<SST>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT DBCHG
"TIME=14-35-46,DATE=99-07-28,SOURCE=123,USERID=CISCO15,DBCHGSEQ=456:
ENT-CRS-VT1:VT1-4-1-2-6-4:::PST-PSTQ,SST"
;

Output Parameters

Table 17-8 REPT DBCHG Output Parameters 

Parameter and Values
Description

TIME

The time of the message triggered by the NE

DATE

The date of the message triggered by the NE

SOURCE

An input-command CTAG if present. String. Maximum length of 20 characters. Optional

USERID

The user name or user identifier. String. Maximum length of 20 characters.Optional

DBCHGSEQ

Identifier or range of identifiers to be retrieved. It is a sequential number of the DBCHGSEQ message. Integer

COMMAND

The input command or substitute. Maximum length of 20 characters. String

AID

Access identifier. Maximum length of 64 characters.Excess characters will be truncated. String

PSTPSTQ

Admin state in the PST-PSTQ format

Parameter type is PST_PSTQ—service state of the entity described by the primary state (SST) and a primary state qualifier (PSTQ)

•IS-NR

In service - normal

•OOS-AU

Out of service - autonomous

•OOS-AUMA

Out of service - autonomous and management

•OOS-MA

Out of service - management

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

•AINS

Automatic in service

•DSBLD

Disabled

•LPBK

Loopback

•MEA

Mismatch of equipment and attributes

•MT

Maintenance mode

•OOG

Out of group

•SWDL

Software downloading

•UAS

Unassigned

•UEQ

Unequipped


17.9  REPT EVT <MOD2ALM>

Report Event (1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, FSTE, G1000, GFPOS, GIGE, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC12, VC3, VCG, VT1, VT2, WLEN)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of a non-alarmed event. Beginning with R5.0,
REPT EVT <MOD2ALM> can report the RMON-managed threshold crossing alarm.

See Table 27-1 for supported modifiers by platform.

Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Output Format

SID DATE TIME
A ATAG REPT EVT <MOD2ALM>
"<AID>:<CONDTYPE>,[<CONDEFF>],,,[<LOCN>],,[<MONVAL>],[<THLEV>],
[<TMPER>]:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT 1GFC
"FAC-5-1:WKSWPR,TC,,,FEND,,12,13,15-MIN:\"WORKING SWITCH TOPROTECTION\",
OC48"
;

Output Parameters

Table 17-9 REPT EVT <MOD2ALM> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "ALL" section

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 node, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

LOCN

Location associated with a particular command in reference to the entity identified by the AID

Parameter type is LOCATION—the location where the action is to take place

•FEND

Action occurs on the Far End of the facility

•NEND

Action occurs on the Near End of the facility

MONVAL

Monitored value. Value to which the register identified by MONTYPE will be initialized or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. Float. Optional

THLEV

Threshold level. Float. Optional

TMPER

Accumulation time period for performance counters. Optional

Parameter type is TMPER—accumulation time period for the performance management center

•1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.

•1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

•1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

•15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

•RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.

DESC

Condition description. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional

Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot

•AD-1B

Optical Add/Drop Multiplexed (OADM) 1 Band Filter

•AD-1C

Optical Add/Drop Multiplexed (OADM) 1 Channel Filter

•AD-2C

Optical Add/Drop Multiplexed (OADM) 2 Channels Filter

•AD-4B

Optical Add/Drop Multiplexed (OADM) 4 Bands Filter

•AD-4C

Optical Add/Drop Multiplexed (OADM) 4 Channels Filter

•AICI

The AICI card

•AIP

The Alarm Indicator Panel

•ALM-PWR

Alarm Power

•ASAP-4

ASAP Carrier card with four PIM slots

•BP

The Backplane of the NE

•CE-100T-8

Eight port CE-100T card on ONS 15454 and ONS 15310-CL

•CRFT-TMG

Craft Timing

•DCC

The Data Communications Channel

•DMX-32

Optical De/Multiplexed (DMX) 32 Channels

•DS1-14

A 14 port interface card supporting DS1 facilities

•DS1N-14

A 14 port interface card supporting DS1 facilities

•DS3-12

A 12 port interface card supporting DS3 facilities

•DS3-3

A three port interface card supporting DS3 facilities

•DS3-EC1-48

High Density DS3/EC1 card supporting 48 ports

•DS3ATM-12

A 12 port interface card supporting DS3 ATM facilities

•DS3CR-12

Cost reduced DS3

•DS3E-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3N-12

A 12 port interface card supporting DS3 facilities

•DS3NE-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

•E1000T-2

A two port interface card supporting 1000 BASE T Ethernet facilities

•E100T-12

A 12 port interface card supporting 100 BASE T Ethernet facilities

•E100T-4

A four port interface card supporting 100 BASE T Ethernet facilities.

•EC1-12

A 12 port interface card supporting EC1 facilities

•EC1N-12

A 12 port interface card supporting EC1 facilities

•FILLER_CARD

Smart Filler card (ONS 15600)

•FTA

The fan tray of the NE

•FTA1

The fan tray 1 of the NE

•FTA2

The fan tray 2 of the NE

•G1K-4

A four port G1000 card

•MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

•MIC-28-3-A

ONS 15327 MIC card A

•MIC-28-3-B

ONS 15327 MIC card B

•MIC-EXT

ONS 15327 MIC card

•MIC-GEN

ONS 15327 MIC card

•ML-100T-8

Eight port 100T card on ONS 15310-CL

•MUX-32

Optical Multiplexed (MUX) 32 Channels

•MXP-2.5G-10G

10G (4 * 2.5G) Muxponder Card

•OC12

An interface card that supports one or more OC-12 (622Mbps) optical facilities

•OC12-327

OC-12 card (ONS 15327)

•OC12-4

A four port OC12 card

•OC12-IR-1

An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities

•OC12-LR-1

An interface card that supports one long range OC-12 (622Mbps) optical facilities

•OC12-SR-1

An interface card that supports one short range OC-12 (622Mbps) optical facilities

•OC192_4

A four port OC192 card (ONS 15600)

•OC192-LR-1

An interface card that supports one or more OC-192 optical facilities

•OC3

An interface card that supports multiple OC-3 (155Mbps) optical facilities

•OC3-327

ONS 15327 OC-3 card

•OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

•OC3-SR-4

An interface card that supports four short range OC-3 (155Mbps) optical facilities

•OC3ATM-IR-6

An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers

•OC3IR-STM1SH-
1310-8

An OC-3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192

•OC3POS-SR-4

An interface card that supports four short range OC-3 (155Mbps) POS optical facilities

•OC48

An interface card that supports one or more OC-48 (10Gbps) optical facilities

•OC48-327

OC-48 card (ONS 15327)

•OC48-AS-1

An interface card that supports one short range OC-48 (10Gbps) optical facilities that can be provisioned in any I/O slot

•OC48-ELR-1

An interface card that supports one short range OC-48 (2.5Gbps) optical facility

•OC48-IR-1

An interface card that supports one intermediate range OC-48 (10Gbs) optical facility

•OC48-LR-1

An interface card that supports one long range OC-48 (10Gbs) optical facility

•OC48-SR-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities

•OC-48_16

16 port OC-48 card (ONS 15600)

•OPT-BST

Optical Booster Amplifier

•OPT-PRE

Optical Preamplifier

•OSC-CSM

Optical Service Channel (OSC) with Combiner/Separator Module (SCM)

•OSCM

Optical Service Channel (OSC) Module

•PIM-4

Pluggable interface module with four PPM slots

•PPM-1

Pluggable port module with 1 port SFP module

•SSXC

Cross connect card (ONS 15600)

•TCC

The Timing Communication and Control card

•TSC

Timing and synchronization controller card (ONS 15600)

•TXP-MR-10G

10G Multirate Transponder Card

•TXP-MR-2.5G

Multirate 2.5G Unprotected

•TXPP-MR-2.5G

Multirate 2.5G Protected

•XCVT

A Cross-Connect card

•XC10G

A Cross-Connect card

•XTC

ONS 15327 XTC card

•XTC-DS1-14

ONS 15327 XTC DS1-14 card

•XTC-DS1-28

ONS 15327 XTC DS1-28 card

•XTC-DS1-56

ONS 15327 XTC DS1-56 card

•XTC-DS3-3

ONS 15327 XTC DS3-3 card


17.10  REPT EVT BITS

Report Event Building Integrated Timing Supply

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports a non-alarmed event against a BITS facility.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Output Format

SID DATE TIME
** ATAG REPT EVT BITS
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT ALM BITS
"BITS-1:SSM-STU,TC,,,,,,,:\"SYNCHRONIZED - TRACEABILITY UNKNOWN\""
;

Output Parameters

Table 17-10 REPT EVT BITS Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "BITS" section

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 node, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

DESC

Condition description. Optional


17.11  REPT EVT COM

Report Event Common

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports a non-alarmed event against an NE when there is no AID associated with it.

Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Output Format

SID DATE TIME
A ATAG REPT EVT COM
"[<AID>]:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT COM
"COM:CLDRESTART,TC,,,,,,,:\"COLD RESTART\","
;

Output Parameters

Table 17-11 REPT EVT COM Output Parameters 

Parameter and Values
Description

AID

Access identifier. Identifies the entity to which the command pertains. String. Optional

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

DESC

Condition description. Optional


17.12  REPT EVT ENV

Report Event Environment

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of a non-alarmed event against an environment alarm input.

Category

Environment

Security

Retrieve

Related Commands

CLR-COND-SECU

OPR-ACO-ALL

OPR-EXT-CONT

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-EXT-CONT

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-ATTR-CONT

RTRV-ATTR-ENV

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-EXT-CONT

SET-ATTR-CONT

SET-ATTR-ENV

SET-ATTR-SECUDFLT


Output Format

SID DATE TIME
A ATAG REPT EVT ENV
"<AID>:<ALMTYPE>,[<CONDEFF>],,,,,,,:[<DESC>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT ENV
"ENV-IN-2:OPENDR,TC,,,,,,,:\"OPEN DOOR\""
;

Output Parameters

Table 17-12 REPT EVT ENV Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "ENV" section. Identifies an environmental input

ALMTYPE

Abbreviated code identifying the alarm

Parameter type is ENV_ALM—environmental alarm types

•AIRCOMPR

Air compressor failure

•AIRCOND

Air conditioning failure

•AIRDRYR

Air dryer failure

•BATDSCHRG

Battery discharging

•BATTERY

Battery failure

•CLFAN

Cooling fan failure

•CPMAJOR

Centralized power major failure

•CPMINOR

Centralized power minor failure

•ENGINE

Engine failure

•ENGOPRG

Engine operating

•ENGTRANS

Standby engine transfer

•EXPLGS

Explosive gas

•FIRDETR

Fire detector failure

•FIRE

Fire

•FLOOD

Flood

•FUELLEAK

Fuel leak

•FUSE

Fuse failure

•GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

•HATCH

CEV hatch fail

•GEN

Generator failure

•HIAIR

High airflow

•HIHUM

High humidity

•HITEMP

High temperature

•HIWTR

High water

•INTRUDER

Intrusion

•LEVELCON

Level converter

•LVDADSL

Secondary ADSL low voltage disconnect

•LVDBYPAS

Low voltage disconnect bypass

•LWBATVG

Low battery voltage

•LWFUEL

Low fuel

•LWHUM

Low humidity

•LWPRES

Low cable pressure

•LWTEMP

Low temperature

•LWWTR

Low water

•MISC

Miscellaneous

•OPENDR

Open door

•POWER

Commercial power failure

•PUMP

Pump failure

•PWR-48

48V power supply failure

•PWR-139

-139V power converter

•PWR-190

-190V power converter

•PWRMJ

Power supply major

•PWRMN

Power supply minor

•RECT

Rectifier failure

•RECTHI

Rectifier high voltage

•RECTLO

Rectifier low voltage

•RINGGENMJ

Ringing generator major

•RINGGENMN

Ringing generator minor

•RTACADSL

AC or AC/rectifier power fail ADSL equipment

•RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

•RTACPWR

AC or AC/rectifier power fail DCL equipment

•RTACPWRENG

Commercial AC fail, site equipped with standby engine

•RTBAYPWR

AC power loss distributed power RT bay

•RTRVENG

Retrieve standby engine, commercial AC restored

•SMOKE

Smoke

•TEMP

High-low temperature

•TOXICGAS

Toxic gas

•TREPEATER

T-repeater shelf

•VENTN

Ventilation system failure

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

DESC

Condition description. Optional


17.13  REPT EVT EQPT

Report Event Equipment

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of a non-alarmed event against an equipment unit or slot.

Category

Equipment

Security

Retrieve

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

CLR-COND-SECU

DLT-EQPT

ED-EQPT

ENT-EQPT

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

REPT RMV EQPT

REPT RST EQPT

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-ALMTH-EQPT

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-EQPT

SET-ALMTH-EQPT

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Output Format

SID DATE TIME
A ATAG REPT EVT EQPT
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT EQPT
"SLOT-7:PLUGIN,TC,,,,,,,:\"EQUIPMENT PLUG-IN\",TCC"
;

Output Parameters

Table 17-13 REPT EVT EQPT Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "EQPT" section. Equipment AID SLOT-{1-17}

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

DESC

Condition description. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional

Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot

•AD-1B

Optical Add/Drop Multiplexed (OADM) 1 Band Filter

•AD-1C

Optical Add/Drop Multiplexed (OADM) 1 Channel Filter

•AD-2C

Optical Add/Drop Multiplexed (OADM) 2 Channels Filter

•AD-4B

Optical Add/Drop Multiplexed (OADM) 4 Bands Filter

•AD-4C

Optical Add/Drop Multiplexed (OADM) 4 Channels Filter

•AICI

The AICI card

•AIP

The Alarm Indicator Panel

•ALM-PWR

Alarm Power

•ASAP-4

ASAP Carrier card with four PIM slots

•BP

The Backplane of the NE

•CE-100T-8

Eight port CE-100T card on ONS 15454 and ONS 15310-CL

•CRFT-TMG

Craft Timing

•DCC

The Data Communications Channel

•DMX-32

Optical De/Multiplexed (DMX) 32 Channels

•DS1-14

A 14 port interface card supporting DS1 facilities

•DS1N-14

A 14 port interface card supporting DS1 facilities

•DS3-12

A 12 port interface card supporting DS3 facilities

•DS3-3

A three port interface card supporting DS3 facilities

•DS3-EC1-48

High Density DS3/EC1 card supporting 48 ports

•DS3ATM-12

A 12 port interface card supporting DS3 ATM facilities

•DS3CR-12

Cost reduced DS3

•DS3E-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3N-12

A 12 port interface card supporting DS3 facilities

•DS3NE-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

•E1000T-2

A two port interface card supporting 1000 Base T Ethernet facilities

•E100T-12

A 12 port interface card supporting 100 Base T Ethernet facilities

•E100T-4

A four port interface card supporting 100 Base T Ethernet facilities.

•EC1-12

A 12 port interface card supporting EC1 facilities

•EC1N-12

A 12 port interface card supporting EC1 facilities

•FILLER_CARD

Smart Filler card (ONS 15600)

•FTA

The fan tray of the NE

•FTA1

The fan tray 1 of the NE

•FTA2

The fan tray 2 of the NE

•G1K-4

A four port G1000 card

•MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

•MIC-28-3-A

ONS 15327 MIC card A

•MIC-28-3-B

ONS 15327 MIC card B

•MIC-EXT

ONS 15327 MIC card

•MIC-GEN

ONS 15327 MIC card

•ML-100T-8

Eight port 100T card on ONS 15310-CL

•MUX-32

Optical Multiplexed (MUX) 32 Channels

•MXP-2.5G-10G

10G (4 * 2.5G) Muxponder Card

•OC12

An interface card that supports one or more OC-12 (622Mbs) optical facilities

•OC12-327

ONS 15327 OC-12 card

•OC12-4

A four port OC-12 card

•OC12-IR-1

An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities

•OC12-LR-1

An interface card that supports one long range OC-12 (622Mbs) optical facilities

•OC12-SR-1

An interface card that supports one short range OC-12 (622Mbs) optical facilities

•OC192_4

Four port OC192 card (ONS 15600)

•OC192-LR-1

An interface card that supports one or more OC-192 optical facilities

•OC3

An interface card that supports multiple OC-3 (155Mbs) optical facilities

•OC3-327

ONS 15327 OC-3 card

•OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

•OC3-SR-4

An interface card that supports four short range OC-3 (155Mbs) optical facilities

•OC3ATM-IR-6

An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers

•OC3IR-STM1SH-
1310-8

An OC-3 card which has eight ports over the lower speed slot of the ONS 15454 with XC10G/192

•OC3POS-SR-4

An interface card that supports four short range OC-3 (155Mbs) POS optical facilities

•OC48

An interface card that supports one or more OC-48 (10Gbs) optical facilities

•OC48-327

ONS 15327 OC-48 card

•OC48-AS-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot

•OC48-ELR-1

An interface card that supports one short range OC-48 (2.5Gbs) optical facility

•OC48-IR-1

An interface card that supports one intermediate range OC-48 (10Gbs) optical facility

•OC48-LR-1

An interface card that supports one long range OC-48 (10Gbs) optical facility

•OC48-SR-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities

•OC-48_16

16 port OC48 card (ONS 15600)

•OPT-BST

Optical Booster Amplifier

•OPT-PRE

Optical Preamplifier

•OSC-CSM

Optical Service Channel (OSC) with Combiner/Separator Module (SCM)

•OSCM

Optical Service Channel (OSC) Module

•PIM-4

Pluggable interface module with 4 PPM slots

•PPM-1

Pluggable port module with 1 port SFP module

•SSXC

Cross connect card (ONS 15600)

•TCC

The Timing Communication and Control card

•TSC

Timing and synchronization controller card (ONS 15600)

•TXP-MR-10G

10G Multirate Transponder Card

•TXP-MR-2.5G

Multirate 2.5G Unprotected

•TXPP-MR-2.5G

Multirate 2.5G Protected

•XCVT

A Cross-Connect card

•XC10G

A Cross-Connect card

•XTC

ONS 15327 XTC card

•XTC-DS1-14

ONS 15327 XTC DS1-14 card

•XTC-DS1-28

ONS 15327 XTC DS1-28 card

•XTC-DS1-56

ONS 15327 XTC DS1-56 card

•XTC-DS3-3

ONS 15327 XTC DS3-3 card


17.14  REPT EVT FXFR

Report Event Software Download

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15310-CL

Reports the FTP software download status of the start, completion, and completed percentage.


Note The FXFR_RSLT is only sent when the FXFR_STATUS is COMPLD.



Note The BYTES_XFRD is only sent when the FXFR_STATUS is IP or COMPLD.


Category

File Transfer

Security

Retrieve

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

CLR-COND-SECU

COPY-RFILE

DLT-TRAPTABLE

ED-DAT

ED-NE-GEN

ED-NE-PATH

ED-NE-SYNCN

ED-TRAPTABLE

ENT-TRAPTABLE

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-HDR

RTRV-INV

RTRV-MAP-NETWORK

RTRV-NE-APC

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

RTRV-TRAPTABLE

SET-TOD


Output Format

SID DATE TIME
A ATAG REPT EVT FXFR
"<FILENAME>,<FXFR_STATUS>,[<FXFR_RSLT>],[<BYTES_XFRD>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT FXFR
"NEW.PKG,COMPLD,SUCCESS,21215147"
;

Output Parameters

Table 17-14 REPT EVT FXFR Output Parameters 

Parameter and Values
Description

FILENAME

When a package is being transferred between the FTP server and the controller cards, the filename field will contain the string ACTIVE. Following this transfer, if there is a second common-control card on the NE, the file will be copied over to the second card during which time REPT EVT FXFR messages will be generated with a filename of STANDBY. String

FXFR_STATUS

The status of the file transfer: Start, IP (in progress), or COMPLD

Parameter type is TX_STATUS—status of the file transfer

•COMPLD

The file transmission is completed

•IP

The file transmission is in progress

•START

The file transmission is started

FXFR_RSLT

The result of the file transfer: Success or Failure. Optional

Parameter type is TX_RSLT—result of the file transfer

•FAILURE

A failed result

•SUCCESS

A successful result

BYTES_XFRD

The percentage of bytes transferred. String. Optional


17.15  REPT EVT IOSCFG

Report Event Internet Operating System Configuration File

Usage Guidelines

Cisco ONS 15454

Reports the status of copying the Cisco IOS configuration file when the COPY-IOSCFG command is issued.


Note You can identify if this message is caused by a Cisco IOS config file downloading/uploading/merging by looking at the SRC and DEST field in the message. See the "COPY-IOSCFG" section for more details.



Note There is no success/failure in the message to indicate the success or failure of the merge process when merging the startup Cisco IOS config file to the running config file.


Category

File Transfer

Security

Retrieve

Related Commands

CLR-COND-SECU

COPY-IOSCFG

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Output Format

SID DATE TIME
A ATAG REPT EVT IOSCFG
"<AID>:<SRC>,<DEST>,<STATUS>,[<RESULT>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT IOSCFG
"SLOT-1:STARTUP,IOS-CONFIG-FILE-IN-NETWORK,COMPLD,SUCCESS"
;

Output Parameters

Table 17-15 REPT EVT IOSCFG Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "EQPT" section. Slot AID for the equipment

SRC

Source access identifier. Specifies where the Cisco IOS config file is copied from. String

DEST

Destination. Specifies where the Cisco IOS config file is copied to. String

STATUS

The status of COPY-IOSCFG: Start, IP, or COMPLD

Parameter type is TX_STATUS—status of the file transfer

•COMPLD

The file transmission is completed

•IP

The file transmission is in progress

•START

The file transmission is started

RESULT

The result of the file transfer: Success or Failure. Optional

Parameter type is TX_RSLT—result of the file transfer

•FAILURE

A failed result

•SUCCESS

A successful result


17.16  REPT EVT SECU

Report Event Security

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of a non-alarmed security event against the NE.

Based on TR-NWT-000835 in TR-NWT-000835 and the AID of the security alarm should be the Connection Identifier (CID) which is not supported in this release. The COM or UID is an acceptable substitute for the AID here. CIDs will be supported in a future release.

For the rule of single failure, single message/alarm, the security alarm will not be reported as
REPT ALM COM, because it is reported as REPT ALM SECU.

Because the NE sends this security message as a transient message, to make all TL1 autonomous messages consistent, the TL1 agent reports the security message into REPT EVT SECU.

This message is inhibited by default. A superuser will have to issue the ALW-MSG-SECU to see this message.

Category

Security

Security

Superuser

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-CMD-SECU

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Output Format

SID DATE TIME
A ATAG REPT EVT SECU
"<AID>:<DNFIELD>,[<CONDEFF>],,,,,,,:<SECURITY>:<DNFIELD1>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SECU
"COM:LOGIN-FAILURE-PSWD,TC,,,,,,,:\"SECURITY:
INVALID LOGIN - PASSWORD - SEE AUDIT LOG\""
;

Output Parameters

Table 17-16 REPT EVT SECU Output Parameters 

Parameter and Values
Description

AID

Access identifier. Identifies an entity with the condition. Defaults to COM. String

DNFIELD

String

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

SECURITY

String

DNFIELD1

String


17.17  REPT EVT SESSION

Report Event Session

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports a non-alarmed event related to establishing a session with the NE.


Note•The WARN field might contain different information depending on the type of session-related event.

•If the password aging feature has not been enabled (or the feature is enabled but the password is not close to expiring):

/*USER <UID> LOGGED IN <IP/SERIAL PORT*/

•If the forced password feature is enforced and the user is logging in for the first time (or the password has expired):

/*PLEASE CHANGE PASSWORD BEFORE CONTINUING*/

•If a session is terminated for any reason (except a user timeout), the reason for the session termination is indicated in the warning (<WARN>).


Category

Security

Security

Retrieve

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-CMD-SECU

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Output Format

SID DATE TIME
A ATAG REPT EVT SESSION
"<AID>:<EXP>,<PCN>"
"<WARN>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SESSION
"TCCP:YES,5-DAY"
"/* USER TERRI LOGGED IN TO TCCP */"
;

Output Parameters

Table 17-17 REPT EVT SESSION Output Parameters 

Parameter and Values
Description

AID

Access identifier. Identifies the NE with which a session is established. String

EXP

Indicates whether the password is alive (for example, no password updating is required at the moment), expired, or is about to expire

Parameter type is YES_NO—indicates whether the user's password is about to expire, the user is logged into the NE or the user is locked out of the NE

•NO

No

•YES

Yes

PCN

The number of days still remaining before the existing password expires. PCN appears only if EXP=YES and either

•The warning period has not been exhausted or

•The user is a new user establishing a session for the first time and the forced password change policy has been activated.

String

WARN

Free format text containing additional information about the security event. String


17.18  REPT EVT SYNCN

Report Event Synchronization

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the occurrence of a non-alarmed event against a synchronization entity.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Output Format

SID DATE TIME
A ATAG REPT EVT SYNCN
"<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,,:[<DESC>],[<AIDDET>]"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SYNCN
"SYNC-NE:SWTOINT,SC,,,,,,,:\"SWITCH TO INTERNAL CLOCK\",TCC"
;

Output Parameters

Table 17-18 REPT EVT SYNCN Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "SYNC_REF" section. Identifies a synchronization reference with alarm condition

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, or ONS 15600 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See "Conditions" for a list of conditions

CONDEFF

The effect of the event on the condition of the NE

Parameter type is COND_EFF—the state of the condition upon the affected unit

•CL

Standing condition cleared

•SC

Standing condition raised

•TC

Transient condition

DESC

Condition description. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. Optional

Parameter type is EQPT_TYPE—the type of equipment being provisioned into a slot

•AD-1B

Optical Add/Drop Multiplexed (OADM) 1 Band Filter

•AD-1C

Optical Add/Drop Multiplexed (OADM) 1 Channel Filter

•AD-2C

Optical Add/Drop Multiplexed (OADM) 2 Channels Filter

•AD-4B

Optical Add/Drop Multiplexed (OADM) 4 Bands Filter

•AD-4C

Optical Add/Drop Multiplexed (OADM) 4 Channels Filter

•AICI

The AICI card

•AIP

The Alarm Indicator Panel

•ALM-PWR

Alarm Power

•ASAP-4

ASAP Carrier card with four PIM slots

•BP

The Backplane of the NE

•CE-100T-8

Eight port CE-100T card on ONS 15454 and ONS 15310-CL

•CRFT-TMG

Craft Timing

•DCC

The Data Communications Channel

•DMX-32

Optical De/Multiplexed (DMX) 32 Channels

•DS1-14

A 14 port interface card supporting DS1 facilities

•DS1N-14

A 14 port interface card supporting DS1 facilities

•DS3-12

A 12 port interface card supporting DS3 facilities

•DS3-3

A three port interface card supporting DS3 facilities

•DS3-EC1-48

High Density DS3/EC1 card supporting 48 ports

•DS3ATM-12

A 12 port interface card supporting DS3 ATM facilities

•DS3CR-12

Cost reduced DS-3

•DS3E-12

A 12 port DS-3 enhancement interface card supporting DS3E facilities

•DS3N-12

A 12 port interface card supporting DS-3 facilities

•DS3NE-12

A 12 port DS3 enhancement interface card supporting DS3E facilities

•DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

•E1000T-2

A two port interface card supporting 1000 BASE T Ethernet facilities

•E100T-12

A 12 port interface card supporting 100 BASE T Ethernet facilities

•E100T-4

A four port interface card supporting 100 BASE T Ethernet facilities

•EC1-12

A 12 port interface card supporting EC1 facilities

•EC1N-12

A 12 port interface card supporting EC1 facilities

•FILLER_CARD

Smart Filler card (ONS 15600)

•FTA

The fan tray of the NE

•FTA1

The fan tray 1 of the NE

•FTA2

The fan tray 2 of the NE

•G1K-4

A four port G1000 card

•MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

•MIC-28-3-A

ONS 15327 MIC card A

•MIC-28-3-B

ONS 15327 MIC card B

•MIC-EXT

ONS 15327 MIC card

•MIC-GEN

ONS 15327 MIC card

•ML-100T-8

Eight port ML-100T card on ONS 15310-CL

•MUX-32

Optical Multiplexed (MUX) 32 Channels

•MXP-2.5G-10G

10G (4 * 2.5G) Muxponder Card

•OC12

An interface card that supports one or more OC-12 (622Mbs) optical facilities

•OC12-327

ONS 15327 OC12 card

•OC12-4

A four port OC12 card

•OC12-IR-1

An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities

•OC12-LR-1

An interface card that supports one long range OC-12 (622Mbs) optical facilities

•OC12-SR-1

An interface card that supports one short range OC-12 (622Mbs) optical facilities

•OC192_4

Four port OC-192 card (ONS 15600)

•OC192-LR-1

An interface card that supports one or more OC-192 optical facilities

•OC3

An interface card that supports multiple OC-3 (155Mbs) optical facilities

•OC3-327

ONS 15327 OC-3 card

•OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

•OC3-SR-4

An interface card that supports four short range OC-3 (155Mbs) optical facilities

•OC3ATM-IR-6

An interface card that supports six intermediate range OC-3 (155Mbs) ATM optical fibers

•OC3IR-STM1SH-
1310-8

An OC3 card which has 8 ports over the lower speed slot of the ONS 15454 with XC10G/192

•OC3POS-SR-4

An interface card that supports four short range OC-3 (155Mbs) POS optical facilities

•OC48

An interface card that supports one or more OC-48 (10Gbs) optical facilities

•OC48-327

ONS 15327 OC-48 card

•OC48-AS-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities that can be provisioned in any I/O slot

•OC48-ELR-1

An interface card that supports one short-range OC-48 (2.5Gbs) optical facility

•OC48-IR-1

An interface card that supports one intermediate-range OC-48 (10Gbs) optical facility

•OC48-LR-1

An interface card that supports one long-range OC-48 (10Gbs) optical facility

•OC48-SR-1

An interface card that supports one short-range OC-48 (10Gbs) optical facilities

•OC-48_16

16 port OC48 card (ONS 15600)

•OPT-BST

Optical Booster Amplifier

•OPT-PRE

Optical Preamplifier

•OSC-CSM

Optical Service Channel (OSC) with Combiner/Separator Module (SCM)

•OSCM

Optical Service Channel (OSC) Module

•PIM-4

Pluggable interface module with four PPM slots

•PPM-1

Pluggable port module with one port SFP module

•SSXC

Cross connect card (ONS 15600)

•TCC

The Timing Communication and Control card

•TSC

Timing and synchronization controller card (ONS 15600)

•TXP-MR-10G

10G Multirate Transponder Card

•TXP-MR-2.5G

Multirate 2.5G Unprotected

•TXPP-MR-2.5G

Multirate 2.5G Protected

•XCVT

A Cross-Connect card

•XC10G

A Cross-Connect card

•XTC

ONS 15327 XTC card

•XTC-DS1-14

ONS 15327 XTC DS1-14 card

•XTC-DS1-28

ONS 15327 XTC DS1-28 card

•XTC-DS1-56

ONS 15327 XTC DS1-56 card

•XTC-DS3-3

ONS 15327 XTC DS3-3 card


17.19  REPT PM <MOD2>

Report Performance Monitoring (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, VT2)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports autonomous monitoring statistics as a result of the schedule created by SCHED-PMREPT.

See Table 27-1 for supported modifiers by platform.

Category

Performance

Security

Retrieve

Related Commands

ALW-PMREPT-ALL

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

DLT-RMONTH-<MOD2_RMON>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

ENT-RMONTH-<MOD2_RMON>

INH-PMREPT-ALL

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMMODE-<STS_PATH>

RTRV-PMSCHED-<MOD2>

RTRV-PMSCHED-ALL

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-RMONTH-<MOD2_RMON>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TH-ALL

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-PMMODE-<STS_PATH>


Output Format

SID DATE TIME
A ATAG REPT PM <MOD2>
"<AID>:<MONTYPE>,<MONVAL>,<VLDTY>,<LOCN>,<DIRN>,<TMPER>,<MONDAT>,
<MONTM>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT PM 10GFC
"FAC-3-1:CVL,10,PRTL,NEND,BTH,15-MIN,05-25,14-46"
;

Output Parameters

Table 17-19 REPT PM <MOD2> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "ALL" section

MONTYPE

Monitored type

Parameter type is ALL_MONTYPE—monitoring type list

•AISSP

Alarm Indication Signal Seconds—Path

•ALL

All possible values

•BBE-PM

OTN—Background Block Errors—Path Monitor Point

•BBE-SM

OTN—Background Block Errors—Section Monitor Point

•BBER-PM

OTN—Background Block Error Ratio—Path Monitor Point expressed as 1/10th of a percentage.

•BBER-SM

OTN—Background Block Error Ratio—Section Monitor Point expressed as 1/10th of a percentage.

•BIEC

FEC—Bit Errors Corrected

•CGV

8B10B—Code Group Violations

•CSSP

Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)

•CVCPP

Coding Violations—CP-Bit Path

•CVL

Coding Violations—Line

•CVP

Coding Violations—Path

•CVS

Coding Violations—Section

•CVV

Coding Violations—Section

•DCG

8B10B—Data Code Groups

•ESAP

Errored Second Type A-Path (DS3XM-12 DS1 PM count)

•ESBP

Errored Second Type B-Path (DS3XM-12 DS1 PM count)

•ESCPP

Errored Seconds—CP—Bit Path

•ESL

Errored Seconds—Line

•ESNPFE

Errored Second -Network Path (DS3XM-12 DS1 PM count)

•ESP

Errored Seconds—Path

•ES-PM

OTN—Errored Seconds—Path Monitor Point

•ES-SM

OTN—Errored Seconds—Section Monitor Point

•ESR

Errored Second—Ratio

•ESR-PM

Errored Seconds Ratio—Path monitor Point expressed as 1/10th of a percentage

•ESR-SM

Errored Seconds Ratio—Section monitor Point expressed as 1/10th of a percentage

•ESS

Errored Seconds—Section

•ESV

Errored Seconds—VT Path

•etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

•etherStatsCollisions

Number of transmit packets that are collisions

•etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets

•etherStatsDropEvents

Number of received frames dropped at the port level

•etherStatsFragments

The total number of packets received that were less than 64 octets

•etherStatsJabbers

The total number of packets received that are longer than 1518 octets

•etherStatsOctets

The total number of octets of data

•etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

•etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

•etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

•FCP

Failure Count—Line

•FC-PM

OTN—Failure Count—Path Monitor Point

•FC-SM

OTN—Failure Count—Section Monitor Point

•HP-AR

Availability Ratio

•HP-BBE

High-Order Path Background Block Error

•HP-BBER

High-Order Path Background Block Error Ratio

•HP-EB

High-Order Path Errored Block

•HP-ES

High-Order Path Errored Second

•HP-ESA

High-Order Path Errored Seconds - A

•HP-ESB

High-Order Path Errored Seconds - B

•HP-ESR

High-Order Path Errored Second Ratio

•HP-FC

High-Order Path Failure Count

•HP-NPJC-PDET

High-Order Path Negative Pointer Justification Count

•HP-NPJC-PGEN

High-Order Path, Negative Pointer Justification Count

•HP-OI

Outage Intensity

•HP-PJCDIFF

High-Order Path Pointer Justification Count Difference

•HP-PJCS-PDET

High-Order Path Pointer Justification Count

•HP-PJCS-PGEN

High-Order Path Pointer Justification Count Seconds

•HP-PPJC-PDET

High-Order Path Positive Pointer Justification Count

•HP-PPJC-PGEN

High-Order Path, Positive Pointer Justification Count

•HP-SEPI

The number of SEP events in available time

•HP-SES

High-Order Path Severely Errored Seconds

•HP-SESR

High-Order Path Severely Errored Second Ratio

•HP-UAS

High-Order Path Unavailable Seconds

•ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

•ifInDiscards

The number of inbound packets

•ifInErrorBytePktss

Receive Error Byte

•ifInErrors

The number of inbound packets (or transmission units) that contained errors

•ifInFramingErrorPkts

Receive Framing Error

•ifInJunkInterPkts

Receive Interpkt Junk

•ifInMulticastPkts

Number of multicast packets received since the last counter reset

•ifInOctets

Number of bytes transmitted since the last counter reset

•ifInUcastPkts

Number of unicast packets received since the last counter reset

•ifOutBroadcastPkts

Number of broadcast packets transmitted

•ifOutDiscards

The number of outbound packets

•ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

•ifOutMulticastPkts

Number of multicast packets transmitted

•ifOutPayloadCrcErrors

Received payload CRC errors

•ifOutUcastPkts

Number of unicast packets transmitted

•IOS

8B10B- Idle Ordered Sets

•IPC

Invalid Packet Count

•LBCL-AVG

Average Laser Bias current in uA

•LBCL-MAX

Maximum Laser Bias current in uA

•LBCL-MIN

Minimum Laser Bias current in uA

•LBCN

Normalized Laser Bias Current for OC3-8

•LBCN-HWT

Laser Bias Current

•LBCN-LWT

Laser Bias Current

•LOSSL

Loss of Signal Seconds—Line

•LP-BBE

Low-Order Path Background Block Error

•LP-BBER

Low-Order Path Background Block Error Ratio

•LP-EB

Low-Order Path Errored Block

•LP-ES

Low-Order Path Errored Second

•LP-ESA

Low-Order Path Errored Seconds-A

•LP-ESB

Low-Order Path Errored Seconds-B

•LP-ESR

Low-Order Path Errored Second Ratio

•LP-FC

Low-Order Path Failure Count

•LP-NPJC-DET

Low-Order Negative Pointer Justification Count, Detected

•LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

•LP-PPJC-DET

Low-Order Positive Pointer Justification Count, Detected

•LP-PPJC-GEN

Low-Order positive Pointer Justification Count, Generated

•LP-SEP

Low-Order Path Severely Errored Period

•LP-SEPI

Low-Order Path Severely Errored Period Intensity

•LP-SES

Low-Order Path Severely Errored

•LP-UAS

Low-Order Path Unavailable Seconds

•MS-PSC

Protection switch count

•MS-PSD

Protection switch duration

•NIOS

8B10B—Non Idle Ordered Sets

•NPJC-PDET

PPJC-PDET:Negative Pointer Justification

•NPJC-PGEN

PPJC-PGEN:Negative Pointer Justification

•OPR-AVG

Average Receive Power in 1/10 uW

•OPR-MAX

Maximum Receive Power in 1/10 uW

•OPR-MIN

Minimum Receive Power in 1/10 uW

•OPRN

Normalized Optical Receive Power for OC3-8

•OPRN-MAX

Maximum value for OPRN

•OPRN-MIN

Minimum value for OPRN

•OPT-AVG

Average Transmit Power in 1/10 uW

•OPT-MAX

Maximum Transmit Power in 1/10 uW

•OPT-MIN

Minimum Transmit Power in 1/10uW

•OPTN

Normalized value for Optical Power Transmitted for the OC3-8 card

•OPTN-MAX

Maximum value for OPTN

•OPTN-MIN

Minimum value for OPTN

•OPWR-AVG

Optical Power—Average Interval Value in 1/10th of dBm

•OPWR-MAX

Optical Power—Maximum Interval Value in 1/10th of dBm

•OPWR-MIN

Optical Power—Minimum Interval Value in 1/10th of dBm

•PPJC-PDET

PPJC-PDET:Positive Pointer Justification

•PPJC-PGEN

PPJC-PGEN:Positive Pointer Justification

•PSC

Protection Switching Count

•PSC-R

Protection Switching Count—Ring

•PSC-S

Protection Switching Count—Span

•PSC-W

Protection Switching Count—Working

•PSD

Protection Switching Duration

•PSD-R

Protection Switching Duration—Ring

•PSD-S

Protection Switching Duration—Span

•PSD-W

Protection Switching Duration—Working

•SASCPP

Severely Errored Framing/AIS Second—CP-Bit Path

•SASP

Severely Errored Framing/AIS Seconds Path

•SEFS

Severely Errored Framing Seconds

•SEFSP

Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)

•SESCPP

Severely Errored Second—CP-Bit Path

•SESL

Severely Errored Second—Line

•SESNPFE

Severely Errored Second - Network Path (DS3XM-12 DS1 PM count)

•SESP

Severely Errored Second—Path

•SES-PM

OTN—Severely Errored Second—Path

•SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as 1/10th of a percentage

•SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as 1/10th of a percentage

•SESS

Severely Errored Second—Section

•SES-SM

OTN—Severely Errored Second—Section Monitor Point

•SESV

Severely Errored Second—VT Path

•UASCPP

Unavailable Second—CP-Bit Path

•UASL

Unavailable Second—Line

•UASNPFE

Unavailable Second - Network Path (DS3XM-12 DS1 PM count)

•UASP

Unavailable Second—Path

•UAS-PM

OTN—Unavailable Second—Path Monitor Point

•UAS-SM

OTN—Unavailable Second—Section Monitor Point

•UASV

Unavailable Second—VT Path

•UNC-WORDS

FEC—Uncorrectable Words

•VPC

Valid Packet Count

MONVAL

The value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. String

VLDTY

Indicates whether the information for the specified time period was accumulated over the entire time period or a portion of that time period. Validity indicator for the reported PM data

Parameter type is VALIDITY—response validity

•COMPL

Complete response

•PRTL

Partial response

LOCN

Location associated with a particular command in reference to the entity identified by the AID

Parameter type is LOCATION—the location where the action is to take place

•FEND

Action occurs on the Far End of the facility

•NEND

Action occurs on the Near End of the facility

DIRN

Direction relative to the entity identified by the AID. Direction of PM relative to the entity identified by the AID

Parameter type is DIRECTION—transmit and receive directions

•BTH

Both transmit and receive directions

•RCV

Receive direction only

•TRMT

Transmit direction only

TMPER

Accumulation time period for performance counters

Parameter type is TMPER—accumulation time period for the performance management center

•1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available

•1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available

•1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available

•15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length

•RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs

MONDAT

The beginning date of the PM or storage register period specified in TMPER. The format is MM-DD. String

MONTM

The beginning time of day of the PM or storage register period specified in TMPER. The format is HH-MM. String


17.20  REPT SW

Report Switch

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

Reports the autonomous switching of a unit in a duplex equipment pair to the standby state and its mate unit to the active state. An automatic report for the occurrence or clearance of an alarm or event that triggers the switch might be associated with the message.

Category

Protection

Security

Retrieve

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

EX-SW-<OCN_BLSR>

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Output Format

SID DATE TIME
A ATAG REPT SW
"<ACTID>,<STDBYID>"
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT SW
"SLOT-8,SLOT-10"
;

Output Parameters

Table 17-20 REPT SW Output Parameters 

Parameter and Values
Description

ACTID

Identifies the equipment unit from the "EQPT" section that was placed in the active state. Parameter grouping cannot be used with this parameter

STDBYID

Identifies the equipment unit from the "EQPT" section that was placed in the standby state. Parameter grouping cannot be used with this parameter



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Sep 3 11:24:24 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.