Table 26-1 Conditions
Condition
|
Description
|
AIS
|
Alarm Indication Signal
|
AIS-L
|
Alarm Indication Signal - Line
|
AIS-P
|
Alarm Indication Signal - Path
|
AIS-V
|
Alarm Indication Signal - VT
|
ALS
|
Automatic Laser Shutdown
|
APC-DISABLED
|
Automatic Power Control Disabled
|
APC-FAIL
|
Automatic Power Control Failure
|
APSB
|
Byte Failure
|
APSC-IMP
|
Improper APS Code
|
APSCDFLTK
|
Default K Byte
|
APSCINCON
|
Inconsistent APS Code
|
APSCM
|
Protection Switching Channel Match Failure
|
APSCNMIS
|
Node Id Mismatch
|
APSIMP
|
APS Invalid Mode
|
APSMM
|
Automatic Protection Switch Mode Mismatch
|
AS-CMD
|
Alarms Suppressed By User Command
|
AS-MT
|
Alarms Suppressed For Maintenance
|
AU-LOF
|
LOF - Administration Unit - Loss of Multi Frame
|
AUD-LOG-LOSS
|
Audit Log 100 Percent Full - Oldest records will be lost
|
AUD-LOG-LOW
|
Audit Log 80 Percent Full
|
AUTOLSROFF
|
Automatic Laser Shutoff Due To High Temperature
|
AUTORESET
|
Automatic System Reset
|
AUTOSW-AIS
|
Automatic Path Protection Switch Caused By AIS
|
AUTOSW-LOP
|
Automatic Path Protection Switch Caused By LOP
|
AUTOSW-PDI
|
Automatic Path Protection Switch Caused By PDI
|
AUTOSW-SDBER
|
Automatic Path Protection Switch Caused By SDBER
|
AUTOSW-SFBER
|
Automatic Path Protection Switch Caused By SFBER
|
AUTOSW-UNEQ
|
Automatic Path Protection Switch Caused By UNEQ
|
BAT-FAIL
|
Battery Failure
|
BAT-HGH-VLT
|
High Volt
|
BAT-LOW-VLT
|
Low Volt
|
BKUPMEMP
|
Primary Non-Volatile Backup Memory Failure
|
BLSROSYNC
|
BLSR Out Of Sync
|
CARLOSS
|
Carrier Loss On The LAN
|
CKTDOWN
|
Signaling Unable to setup circuit
|
CLDRESTART
|
Cold Restart
|
COMIOXC
|
IO Slot To XCON Communication Failure
|
COMM-FAIL
|
Plug-in Module Communication Failure
|
CONTBUS-A-18
|
TCC A To DCC A Processor Communication Failure
|
CONTBUS-B-18
|
TCC B To DCC B Processor Communication Failure
|
CONTBUS_A
|
Controller A To Shelf Slot Communication Failure
|
CONTBUS_B
|
Controller B To Shelf Slot Communication Failure
|
CTNEQPT-MISMATCH
|
Connection Equipment Mismatch
|
CTNEQPT-PBPROT
|
Interconnection Equipment Failure - Protect XC Payload Bus
|
CTNEQPT-PBWORK
|
Interconnection Equipment Failure - Working XC Payload Bus
|
DATAFLT
|
Software Fault - Data Integrity Fault
|
DBOSYNC
|
Standby Database Out of Sync
|
DS3-MISM
|
DS3 Frame Format Mismatch
|
DSP-COMM-FAIL
|
DSP Communication Failure
|
DSP-FAIL
|
DSP Failure
|
DUP-IPADDR
|
IP address already in use within the same DCC Area
|
DUP-NODENAME
|
Node name already in use within the same DCC Area
|
E-W-MISMATCH
|
Both Ends Of Fiber Provisioned As East Or Both As West
|
EHIBATVG
|
Extreme High Volt
|
ELWBATVG
|
Extreme Low Volt
|
EOC
|
SDCC Termination Failure
|
EOC-L
|
Line DCC Termination Failure
|
EQPT
|
Equipment Failure
|
EQPT-MISS
|
Replaceable Equipment/Unit is Missing
|
ERFI-P-CONN
|
Enhanced Remote Failure Indication - Path - Connectivity
|
ERFI-P-PAYLD
|
Enhanced Remote Failure Indication - Path - Payload
|
ERFI-P-SRVR
|
Enhanced Remote Failure Indication - Path - Server
|
ERROR-CONFIG
|
Error in Startup Config
|
ETH-LINKLOSS
|
Rear Panel Ethernet Link Removed
|
EXCCOL
|
Excess Collisions On The LAN
|
EXERCISE-RING-FAIL
|
Exercise Request on Ring Failed
|
EXERCISE-RING-REQ
|
Exercise Request on Ring
|
EXERCISE-SPAN-FAIL
|
Exercise Request on Span Failed
|
EXERCISE-SPAN-REQ
|
Exercise Request on Span
|
EXT
|
Failure Detected External To The NE
|
EXTRA-TRAF-PREEMPT
|
Extra Traffic Preempted
|
FAILTOSW
|
Failure To Switch To Protection
|
FAILTOSW-PATH
|
Failure To Switch To Protection - Path
|
FAILTOSWR
|
Failure To Switch To Protection - Ring
|
FAILTOSWS
|
Failure To Switch To Protection - Span
|
FAN
|
Fan Failure
|
FANDEGRADE
|
Partial Fan Failure
|
FE-AIS
|
Far End AIS
|
FE-DS1-MULTLOS
|
Far End Multiple DS1 LOS Detected On DS3
|
FE-DS1-NSA
|
Far End DS1 Equipment Failure - Non Service Affecting
|
FE-DS1-SA
|
Far End DS1 Equipment Failure - Service Affecting
|
FE-DS1-SNGLLOS
|
Far End Single DS1 LOS
|
FE-DS3-NSA
|
Far End DS3 Equipment Failure - Non Service Affecting
|
FE-DS3-SA
|
Far End DS3 Equipment Failure - Service Affecting
|
FE-EQPT-NSA
|
Far End Common Equipment Failure - Non Service Affecting
|
FE-EXERCISING-RING
|
Far End Exercising Ring
|
FE-EXERCISING-SPAN
|
Far End Exercising Span
|
FE-FRCDWKSWPR-RING
|
Far End Working Facility Forced To Switch To Protection - Ring
|
FE-FRCDWKSWPR-SPAN
|
Far End Working Facility Forced To Switch To Protection - Span
|
FE-IDLE
|
Far End IDLE
|
FE-LOCKOUTOFPR-SPAN
|
Far End Lockout Of Protection - Span
|
FE-LOF
|
Far End LOF
|
FE-LOS
|
Far End LOS
|
FE-MANWKSWPR-RING
|
Far End Manual Switch Of Working Facility To Protection - Ring
|
FE-MANWKSWPR-SPAN
|
Far End Manual Switch Of Working Facility To Protection - Span
|
FEC-MISM
|
FEC Mismatch
|
FEPRLF
|
Far End Protection Line Failure
|
FORCED-REQ
|
Forced Switch Request
|
FORCED-REQ-RING
|
Forced Switch Request On Ring
|
FORCED-REQ-SPAN
|
Forced Switch Request On Span
|
FRCDSWTOINT
|
Forced Switch To Internal Clock
|
FRCDSWTOPRI
|
Forced Switch To Primary Reference
|
FRCDSWTOSEC
|
Forced Switch To Second Reference
|
FRCDSWTOTHIRD
|
Forced Switch To Third Reference
|
FRNGSYNC
|
Free Running Synchronization Mode
|
FSTSYNC
|
Fast Start Synchronization Mode
|
FULLPASSTHR-BI
|
Bidirectional Full Pass Through Is Active
|
GCC-EOC
|
GCC Termination Failure
|
GE-OOSYNC
|
GigaBit Ethernet Out of Sync
|
HI-LASERBIAS
|
Equipment High Laser Bias
|
HI-RXPOWER
|
Equipment High Rx power
|
HI-TXPOWER
|
Equipment High Tx power
|
HITEMP
|
High Temperature
|
HLDOVRSYNC
|
Holdover Synchronization Mode
|
I-HITEMP
|
Industrial High Temperature
|
IMPROPRMVL
|
Improper Removal
|
INC-GFP-OUTOFFRAME
|
Out Of Frame Detected by GFP Receiver
|
INC-GFP-SIGLOSS
|
Client Signal Loss Frames Detected by GFP Receiver
|
INC-ISD
|
DS3 Idle Condition
|
INC-SIGLOSS
|
Incoming Signal Loss on Fibre Channel Interface
|
INC-SYNCLOSS
|
Incoming Synchronization Loss on Fibre Channel Interface
|
INC_GFP_SYNCLOSS
|
Client Synchronization Loss Frames Detected by GFP Receiver
|
INHSWPR
|
Inhibit Switch To Protect Request On Equipment
|
INHSWWKG
|
Inhibit Switch To Working Request On Equipment
|
INTRUSION-PSWD
|
Security Intrusion Attempt Detected - See Audit Log
|
INVMACADR
|
Invalid MAC Address
|
IOSCFGCOPY
|
Ios Config Copy In Progress
|
KB-PASSTHR
|
K Bytes Pass Through Is Active
|
KBYTE-APS-CHANNEL-FAILURE
|
Kbyte Channel Failure
|
LAN-POL-REV
|
Lan Connection Polarity Reversed
|
LASEREOL
|
Laser Approaching End of Life
|
LKOUTPR-S
|
Lockout Of Protection - Span
|
LMP-HELLODOWN
|
LMP Hello FSM to Control Channel down
|
LMP-NDFAIL
|
LMP Neighbor Discovery has failed
|
LO-RXPOWER
|
Equipment Low Rx power
|
LO-TXPOWER
|
Equipment Low Tx power
|
LOA
|
Loss of Alignment
|
LOC
|
Loss of Channel
|
LOCKOUT-REQ
|
Lockout Switch Request On Facility or Equipment
|
LOCKOUT-REQ-RING
|
Lockout Switch Request On Ring
|
LOF
|
Loss Of Frame
|
LOM
|
Loss of Multi-Frame
|
LOP-P
|
Loss Of Pointer - Path
|
LOP-V
|
Loss Of Pointer - VT
|
LOS
|
Loss Of Signal
|
LPBKCRS
|
Cross-connect Loopback
|
LPBKDS1FEAC
|
DS1 Loopback Due To FEAC Command
|
LPBKDS1FEAC-CMD
|
DS1 Loopback Command Sent To Far End
|
LPBKDS3FEAC
|
DS3 Loopback Due To FEAC Command
|
LPBKDS3FEAC-CMD
|
DS3 Loopback Command Sent To Far End
|
LPBKFACILITY
|
Facility Loopback
|
LPBKTERMINAL
|
Terminal Loopback
|
LWBATVG
|
Low Volt
|
MAN-REQ
|
Manual Switch Request
|
MANRESET
|
Manual System Reset
|
MANSWTOINT
|
Manual Switch To Internal Clock
|
MANSWTOPRI
|
Manual Switch To Primary Reference
|
MANSWTOSEC
|
Manual Switch To Second Reference
|
MANSWTOTHIRD
|
Manual Switch To Third Reference
|
MANUAL-REQ-RING
|
Manual Switch Request On Ring
|
MANUAL-REQ-SPAN
|
Manual Switch Request On Span
|
MEA
|
Mismatch Of Equipment And Attributes
|
MEM-GONE
|
Free Memory On Card Near Zero
|
MEM-LOW
|
Free Memory On Card Very Low
|
MFGMEM
|
Manufacturing Data Memory (EEPROM Failure
|
NO-CONFIG
|
No Startup Config
|
NTWTPINC
|
Network Topology Incomplete
|
OCHNC-ACTIV-FAIL
|
Optical Channel Activation Failure
|
OCHNC-DEACTIV-FAIL
|
Optical Channel De-Activation Failure
|
OCHNC-FAIL
|
Optical Channel Connection Failure
|
OCHNC-INC
|
Optical Channel Incomplete
|
ODUK-AIS-PM
|
ODUk: Alarm Indication Signal
|
ODUK-BDI-PM
|
ODUk: PM Backward Defect Indication
|
ODUK-LCK-PM
|
ODUk: Locked Defect - PM
|
ODUK-OCI-PM
|
ODUk: Open Connection Indication
|
ODUK-SD-PM
|
ODUk: Signal Degrade
|
ODUK-SF-PM
|
ODUk: Signal Failure
|
ODUK-TIM-PM
|
ODUk: Trail Trace Identifier Mismatch
|
OOU-TPT
|
Out of Use - Transport Failure
|
OPTNTWMIS
|
Optical Network Type Mismatch
|
OTUK-AIS
|
OTUk: Alarm Indication Signal
|
OTUK-BDI
|
OTUk: Backward Defect Indication
|
OTUK-LOF
|
OTUk: Loss Of Frame
|
OTUK-SD
|
OTUk: Signal Degrade
|
OTUK-SF
|
OTUk: Signal Failure
|
OTUK-TIM
|
OTUk: Trail Trace Identifier Mismatch
|
OUT-OF-SYNC
|
8B10B Out of Sync
|
PDI-P
|
Payload Defect Indication - Path
|
PEER-NORESPONSE
|
Peer Card Not Responding
|
PLM-P
|
Payload Label Mismatch - Path
|
PLM-V
|
Signal Label Mismatch Failure - Payload Label Mismatch - VT
|
PORT-CODE-MISM
|
Pluggable Port security code mismatch
|
PORT-COMM-FAIL
|
Module Communication Failure
|
PORT-MISMATCH
|
Pluggable Port rate mismatch
|
PORT-MISSING
|
Pluggable Port missing
|
PRC-DUPID
|
Duplicate Node ID
|
PROTNA
|
Protection Unit Not Available
|
PTIM
|
Payload Type Identifier Mismatch
|
PWR-REDUN
|
Redundant Power Capability Lost
|
RAI
|
Remote Alarm Indication
|
RCVR-MISS
|
Facility Termination Equipment - Receiver Missing
|
RFI
|
Remote Failure Indication
|
RFI-L
|
Remote Failure Indication - Line
|
RFI-P
|
One-Bit Remote Failure Indication - Path
|
RFI-V
|
Remote Failure Indication - VT
|
RING-ID-MIS
|
Ring Id Mismatch
|
RING-MISMATCH
|
Far End Of Fiber Is Provisioned With Different Ring ID
|
RING-SW-EAST
|
Ring Switch Is Active On The East Side
|
RING-SW-WEST
|
Ring Switch Is Active On The West Side
|
RSVP-HELLODOWN
|
RSVP Hello FSM to Neighbor down
|
RUNCFG-SAVENEED
|
Need to Save Running Config
|
SD
|
Signal Degrade
|
SD-L
|
BER Threshold Exceeded For Signal Degrade - Line
|
SD-P
|
BER Threshold Exceeded For Signal Degrade - Path
|
SF
|
Signal Failure
|
SF-L
|
BER Threshold Exceeded For Signal Failure - Line
|
SF-P
|
BER Threshold Exceeded For Signal Failure - Path
|
SFTWDOWN
|
Software Download In Progress
|
SNTP-HOST
|
SNTP Host Failure
|
SPAN-SW-EAST
|
Span Switch Is Active On The East Side
|
SPAN-SW-WEST
|
Span Switch Is Active On The West Side
|
SQM
|
Sequence Mismatch
|
SQUELCH
|
Ring Is Squelching Traffic
|
SQUELCHED
|
Equipment Squelched
|
SSM-DUS
|
Do Not Use For Synchronization
|
SSM-FAIL
|
Failed To Receive Synchronization Status Message
|
SSM-LNC
|
G812 - Local Node Clock traceable
|
SSM-OFF
|
Synchronization Status Messages Are Disabled On This Interface
|
SSM-PRC
|
G811 - Primary Reference Clock traceable
|
SSM-PRS
|
Stratum 1 Primary Reference Source Traceable
|
SSM-RES
|
Reserved For Network Synchronization Use
|
SSM-SDH-TN
|
G812 - Transit Node Clock traceable
|
SSM-SETS
|
G813 - Synchronous Equipment Timing Source traceable
|
SSM-SMC
|
SONET Minimum Clock Traceable
|
SSM-ST2
|
Stratum 2 Traceable
|
SSM-ST3
|
Stratum 3 Traceable
|
SSM-ST3E
|
Stratum 3E Traceable
|
SSM-ST4
|
Stratum 4 Traceable
|
SSM-STU
|
Synchronized - Traceability Unknown
|
SSM-TNC
|
Transit Node Clock Traceable
|
SWMTXMOD
|
Switching Matrix Module Failure
|
SWTOPRI
|
Switch To Primary Reference
|
SWTOSEC
|
Switch To Second Reference
|
SWTOTHIRD
|
Switch To Third Reference
|
SYNC-FREQ
|
Synchronization Reference Frequency Out Of Bounds
|
SYNCPRI
|
Primary Synchronization Reference Failure
|
SYNCSEC
|
Secondary Synchronization Reference Failure
|
SYNCTHIRD
|
Third Synchronization Reference Failure
|
SYSBOOT
|
System Reboot
|
TIM
|
TIM Section - Trace Identifier Mismatch Failure
|
TIM-MON
|
TIM Section Monitor - Trace Identifier Mismatch Failure
|
TIM-P
|
STS Path Trace Identifier Mismatch
|
TPTFAIL
|
Transport layer failure
|
TRMT
|
Transmit Failure
|
TRMT-MISS
|
Facility Termination Equipment - Transmitter Missing
|
TUNDERRUN
|
Ether tx underrun
|
TX-AIS
|
Alarm Indication Signal in TX
|
TX-RAI
|
Remote Alarm Indication in TX
|
UNC-WORD
|
FEC Uncorrected Word
|
UNEQ-P
|
Unequipped - Path
|
UNEQ-V
|
Signal Label Mismatch Failure - Unequipped VT
|
VCG-DEG
|
VCAT Group Degraded
|
VCG-DOWN
|
VCAT Group Down
|
WKSWPR
|
Switched To Protection
|
WTR
|
Wait To Restore
|
WVL-MISMATCH
|
Equipment Wavelength Mismatch
|