|
Table Of Contents
Access Identifiers
This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL, Release 6.0.25.1 Access Identifiers
The AID code directs an input command to its intended physical or data entity inside the NE. Equipment modules and facilities are typical examples of entities addressed by the access code. The AIDs in this section apply to the SONET ONS 15454, ONS 15327, ONS 15310-CL, and ONS 15600, except where noted.
25.1.1 ALL
25.1.2 AidUnionId
25.1.3 AidUnionId1
25.1.4 BAND
(Cisco ONS 15454 only)
The BAND AID is used to access Optical Multiplex Section (OMS) layer of Optical Network units.
25.1.5 BITS
AID for BITS (Building Integrated Timing Supply).
25.1.6 BLSR
BLSR AIDs are used to access the specific BLSR of the NE. Applies to the ONS 15454 and the ONS 15600.
25.1.7 CHANNEL
(Cisco ONS 15454 only)
Accesses the Optical Channels (OCH) layer of Optical Network units.
25.1.8 COM
Common
25.1.9 CrossConnectId
25.1.10 CrossConnectId1
25.1.11 DS1
(Cisco ONS 15454 only)
Used to access the DS-1 frame layer of the DS3XM. The format is DS1-[SLOT]-[DS3PORT]-[DS1PORT]
25.1.12 ENV
The environmental AID for the AICI cards
25.1.13 EQPT
Equipment AIDs are used to access specific cards.
In the ONS 15454, the OC-48/OC-192 cards are only used in Slots 5, 6, 12, 13.
In the ONS 15327, Slots 1 through 4 are for multiservice cards (Ethernet and optical cards). Slots 5 and 6 are for the XTC cards, and Slots 7 and 8 are for the MIC cards.
In the ONS 15600, Slots 1 through 4 and Slots 11 through 14 are used for optical cards. Slots 5 and 10 are reserved for the TSC cards. Slots 6 and 7, and Slots 8 and 9 are reserved for the SSXC cards.
25.1.14 FACILITY
Facilities AIDs are used to access specific ports. Applicable to Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL.
Note Because the ONS 15310-CL supports more than one type of facility per slot, the FAC-AID format is not supported. The format Tn-, EC1- , and OCn- is used instead.
ONS 15454, ONS 15327, and ONS 15600 Facility AID format:
•Format for Optical and EC1 facilities without PPM: FAC-[SLOT]-[PORT]
•Format for Optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
•Format for Optical facilities with PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
•Format for DS1-flavored electrical facilities: FAC-[SLOT]-[PORT]
•Format for DS3-flavored (including DS3I) Electrical Facilities: FAC-[SLOT]-[PORT]
•Format for POS Ports: VFAC-[SLOT]-[PORT]
•Format for POS Port with PIM and PPM:VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
ONS 15310-CL Facility AID format:
•Format for Optical Facilities Without PPM: OCn-[SLOT]-[PORT]
•Format for Optical Facilities With PPM: OCn-[SLOT]-[PPM]-[PORT]
•Format for EC1 Facilities: EC1-[SLOT]-[PORT]
•Format for DS1-Flavored Electrical Facilities: T1-[SLOT]-[PORT]
•Format for DS3-Flavored Electrical Facilities: T3-[SLOT]-[PORT]
•Format for POS Ports: VFAC-[SLOT]-[PORT]
•Format for FSTE Ethernet Facilities: FSTE-[SLOT]-[PORT]
25.1.15 IPADDR
IP Address
25.1.16 LINE
(Cisco ONS 15454 only)
The LINE AID is used to access the Optical Transport Section (OTS) layer of optical network units. Applicable only to ONS 15454 AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION].
25.1.17 LNKTERM
Link Termination AIDs that are used to access the termination points of a provisionable patchcord.
25.1.18 OPM
OPM AIDs represent the single wavelength inside an optical power monitoring object
25.1.19 OSC
(Cisco ONS 15454 only)
OSC AIDs are used to access the OSC of the NE
25.1.20 PRSLOT
(Cisco ONS 15454 only)
Valid protection slots for the electrical cards
25.1.21 RFILE
File transfer type. Applicable to ONS 15454, 15327, and 15310-CL.
Table 25-21 RFILE
Pattern DescriptionRFILE-DB
Transferring the system database
RFILE-PKG
Transferring a software package
25.1.22 STS
SONET frame-level AID set
•STS AID Format for Optical and EC1 Facilities Without PPM: STS-[SLOT]-[PORT]-[STS]
•STS AID Format for Optical Facilities With PPM: STS-[SLOT]-[PPM]-[PORT]-[STS]
•STS AID Format for optical facilities With PIM and PPM: STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
•STS AID Format for DS1 electrical facilities: STS-[SLOT]-[STS]
•STS AID Format for DS3 (Except DS3I) electrical facilities: STS-[SLOT]-[PORT]-[STS]
•STS AID Format for DS3I electrical facilities: STS-[SLOT]-[STS]
•STS AID Format for G1K-4 card GIGE facilities: FAC-[SLOT]-[PORT]
25.1.23 SYN
Synchronization AIDs
25.1.24 SYN_SRC
Synchronization source
25.1.25 SYNC_REF
Synchronization AIDs
ONS 15454 Facility AID format for line timing:
•Format for optical facilities without PPM: FAC-[SLOT]-[PORT]
•Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
ONS 15600 facility AID format for line timing:
•Format for optical without PPM: FAC-[SLOT]-[PORT]
•Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
•Format for optical facilities with PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
ONS 15310-CL facility AID format for line timing:
•Format for optical facilities with PPM: OCn-[SLOT]-[PPM]-[PORT] where n={3,12}
•Format for DS1-flavored electrical facilities: T1-[SLOT]-[PORT]
25.1.26 SYNCSW
New synchronization reference that will be used
25.1.27 UDC
UDC AIDs for F-UDC and DCC-UDC channels on the AIC-I card. Applicable to ONS 15454. Applicable to ONS 15310-CL (F-UDC only).
25.1.28 VT
Virtual tributary. Applicable to ONS 15454, ONS 15327, and ONS 15310-CL.
•VT1 AID Format for Optical and EC1 Facilities Without PPM: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for Optical Facilities With PPM: VT1-[SLOT]-[PPM]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for DS1 Electrical Facilities: VT1-[SLOT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for DS3 Electrical Facilities: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
25.1.29 WDMANS
(Cisco ONS 15454 only)
This AID is used to access the AONS application of the NE.
25.1.30 WLEN
(Cisco ONS 15454 only)
This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line), the wavelengths contained are all the available in the node (currently 32). If the facility is of type OCH (CHAN) the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.
Posted: Mon Sep 3 11:06:16 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.