Table Of Contents
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
NTP-A89 Modify Line Settings and PM Parameter Thresholds for OC-N Cards
NTP-A90 Modify Alarm Interface Controller Settings
NTP-A118 Modify Alarm Interface Controller-International Settings
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
NTP-A297 Change Card Service State
Change Card Settings
This chapter explains how to change line provisioning, thresholds, and service states on Cisco ONS 15454 cards.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide as necessary.
Caution Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards—As needed, complete this procedure to change line and threshold settings for all electrical cards (EC-1, DS-1, DS-3, DS3i-N-12, and DS3XM).
2. A89 Modify Line Settings and PM Parameter Thresholds for OC-N Cards—As needed, complete this procedure to change line and threshold settings for all optical (OC-N) cards.
3. A90 Modify Alarm Interface Controller Settings—As needed, complete this procedure to change external alarms and controls (environmental alarms) and/or orderwire settings.
4. A118 Modify Alarm Interface Controller-International Settings—As needed, complete this procedure to change external alarms and controls and/or orderwire settings.
5. A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection—As needed, complete this procedure to change the protection type on DS-1 or DS-3 cards.
6. A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards—As needed, complete this procedure to change FC_MR-4 card port and threshold settings.
7. A297 Change Card Service State—As needed, complete this procedure to change card service state.
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the electrical card settings. If you are already logged in, proceed to Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4 to preserve the existing database.
Step 3 Perform any of the following tasks as needed:
• A165 Change Line and Threshold Settings for the DS1-14 or DS1N-14 Cards
• A166 Change Line and Threshold Settings for the DS3-12 or DS3N-12 Cards
• A167 Change Line and Threshold Settings for the DS3-12E or DS3N-12E Cards
• A168 Change Line and Threshold Settings for the DS3XM-6 Card
• DLP-A387 Change Line and Threshold Settings for the DS3XM-12 Card, page 20-74
• A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
• DLP-A388 Change Line and Threshold Settings for the DS3/EC1-48 Cards, page 20-80
• A169 Change Line and Threshold Settings for the EC1-12 Card
Step 4 When you are finished changing the card settings, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A89 Modify Line Settings and PM Parameter Thresholds for OC-N Cards
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the OC-N card settings. If you are already logged in, proceed to Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• A170 Change Line Transmission Settings for OC-N Cards
• A171 Change Threshold Settings for OC-N Cards
• A172 Change an Optical Port to SDH
Step 4 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A90 Modify Alarm Interface Controller Settings
Purpose
This procedure provisions the AIC card to receive input from, or send output to, external devices wired to the backplane (called external alarms and controls or environmental alarms) and changes orderwire settings.
Tools/Equipment
None
Prerequisite Procedures
NTP-A32 Provision External Alarms and Controls on the Alarm Interface Controller, page 7-9
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the AIC card settings. If you are already logged in, proceed to Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• A173 Change External Alarms Using the AIC Card
• A174 Change External Controls Using the AIC Card
• A175 Change Orderwire Settings Using the AIC Card
Step 4 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A118 Modify Alarm Interface Controller-International Settings
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the AIC-I card settings. If you are already logged in, proceed to Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A208 Change External Alarms Using the AIC-I Card, page 19-6
• DLP-A209 Change External Controls Using the AIC-I Card, page 19-7
• DLP-A210 Change AIC-I Card Orderwire Settings, page 19-8
Step 4 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to convert the DS-1 or DS-3 cards from 1:1 to 1:N protection. If you are already logged in, proceed to Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• A176 Convert DS1-14 Cards From 1:1 to 1:N Protection
• A177 Convert DS3-12 Cards From 1:1 to 1:N Protection
• A178 Convert DS3-12E Cards From 1:1 to 1:N Protection
Step 4 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the OC-N card settings. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A438 Change General Port Settings for the FC_MR-4 Card, page 21-16
• DLP-A439 Change Distance Extension Port Settings for the FC_MR-4 Card, page 21-18
• DLP-A440 Change Enhanced FC/FICON Port Settings for the FC_MR-4 Card, page 21-19
• DLP-A357 Create FC_MR-4 RMON Alarm Thresholds, page 20-41
• DLP-A358 Delete FC_MR-4 RMON Alarm Thresholds, page 20-45
Step 4 Complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A297 Change Card Service State
Purpose
This procedure changes card service state.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-66 at the node where you want to change the card service state.
Step 2 Click the Inventory tab.
Step 3 Click Admin State for the card you want to change, and choose an Admin state from the drop-down list: IS (In-Service) or OOS,MT (Out-of-Service,Maintenance).
Step 4 Click Apply.
Step 5 If an error message opens indicating that the card state cannot be changed from its current state, click OK.
Table 11-1 lists possible card service state transitions based on the Admin State chosen. For more information about the enhanced state model and card state transitions, refer to the "Administrative and Service States" appendix of the Cisco ONS 15454 Reference Manual.
Stop. You have completed this procedure.