11.1 Overview

11.2 Craft Interface

11.3 TL1 Access using Telnet

11.4 Alarms

11.4.1 Equipment Alarms

11.4.2 OC-N Alarms

11.4.3 DS-3 Alarms

11.4.4 DS-1 Alarms

11.4.5 STS Alarms

11.4.6 VT Termination Alarms

11.4.7 BITS Alarms

11.4.8 Network Element Synch Ref Alarms

11.5 Autonomous Messages

11.6 Performance Monitoring

11.6.1 Performance Monitoring Statistics

11.7 TL1 Command Syntax

11.8 TL1 Command Privilege Map

11.9 TL1 Command List

11.9.1 Cross Connect

11.9.2 Environment

11.9.3 Equipment

11.9.4 Facility

11.9.5 Facility Protection

11.9.6 Fault

11.9.7 Log

11.9.8 Performance

11.9.9 Security

11.9.10 Switch

11.9.11 Synchronization

11.9.12 System

11.9.13 Testing

11.9.14 Other

11.10 TL1 Command Index

11.11 TL1 Command Description

11.11.1 ACT-USER: Activate User

11.11.2 ALW-MSG-ALL: Allow Message All

11.11.3 CANC-USER: Cancel User

11.11.4 DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.5 DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)

11.11.6 DLT-CRS-VT1: Delete Cross Connect Virtual Tributary

11.11.7 DLT-EQPT: Delete Equipment

11.11.8 DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)

11.11.9 DLT-FFP-EQPT: Delete Facilities Protection Equipment

11.11.10 DLT-USER-SECU: Delete User Security

11.11.11 ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)

11.11.12 ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)

11.11.13 ED-BITS: Edit Building Integrated Timing Supply

11.11.14 ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)

11.11.15 ED-CRS-VT1: Edit Cross Connect Virtual Tributary

11.11.16 ED-DAT: Edit Date and Time

11.11.17 ED-EC1: Edit Electrical Carrier Level 1

11.11.18 ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)

11.11.19 ED-FFP-EQPT: Edit Equipment Protection

11.11.20 ED-NE: Edit Network Element

11.11.21 ED-PID: Edit Private Identifier

11.11.22 ED-SYNCN: Edit Synchronization

11.11.23 ED-T1: Edit T1

11.11.24 ED-T3: Edit T3

11.11.25 ED-USER-SECU: Edit User Security

11.11.26 ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.27 ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)

11.11.28 ENT-CRS-VT1: Enter Cross Connect Virtual Tributary

11.11.29 ENT-EQPT: Enter Equipment

11.11.30 ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)

11.11.31 ENT-FFP-EQPT: Enter Equipment Protection

11.11.32 ENT-USER-SECU: Enter User Security

11.11.33 INH-MSG-ALL: Inhibit Message All

11.11.34 INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.35 INIT-SYS: Initialize System

11.11.36 OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)

11.11.37 OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1

11.11.38 OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1

11.11.39 OPR-LPBK-T1: Operate Loopback T1

11.11.40 OPR-LPBK-T3: Operate Loopback T3

11.11.41 OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)

11.11.42 OPR-PROTNSW-EQPT: Operate Protection Switch Equipment

11.11.43 OPR-UPGRADE: Operate Upgrade

11.11.44 REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.45 REPT ALM BITS: Report Alarm Building Integrated Timing Supply

11.11.46 REPT ALM ENV: Report Alarm Environment

11.11.47 REPT ALM EQPT: Report Alarm Equipment

11.11.48 REPT ALM SYNCN: Report Alarm Synchronization

11.11.49 REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.50 REPT EVT EQPT: Report Event Equipment

11.11.51 REPT EVT SYNCN: Report Event Synchronization

11.11.52 RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)

11.11.53 RLS-LPBK-DS1: Release Loopback Digital Signal Level 1

11.11.54 RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1

11.11.55 RLS-LPBK-T1: Release Loopback T1 Facility

11.11.56 RLS-LPBK-T3: Release Loopback T3 Facility

11.11.57 RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)

11.11.58 RLS-PROTNSW-EQPT: Release Protection Switch Equipment

11.11.59 RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.60 RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.61 RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)

11.11.62 RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)

11.11.63 RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)

11.11.64 RTRV-ALM-ALL: Retrieve Alarm All

11.11.65 RTRV-ALM-BITS: Retrieve Alarm Building Integrated Timing Supply

11.11.66 RTRV-ALM-ENV: Retrieve Alarm Environment

11.11.67 RTRV-ALM-EQPT: Retrieve Alarm Equipment

11.11.68 RTRV-ALM-SYNCN: Retrieve Alarm Synchronization

11.11.69 RTRV-BITS: Retrieve Building Integrated Timing Supply

11.11.70 RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.71 RTRV-COND-ALL: Retrieve Condition All

11.11.72 RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply

11.11.73 RTRV-COND-EQPT: Retrieve Condition Equipment

11.11.74 RTRV-COND-SYNCN: Retrieve Condition Synchronization

11.11.75 RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)

11.11.76 RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary

11.11.77 RTRV-EC1: Retrieve Electrical Carrier Level 1

11.11.78 RTRV-EQPT: Retrieve Equipment

11.11.79 RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)

11.11.80 RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment

11.11.81 RTRV-HDR: Retrieve Header

11.11.82 RTRV-INV: Retrieve Inventory

11.11.83 RTRV-LOG: Retrieve Log

11.11.84 RTRV-NE: Retrieve Network Element

11.11.85 RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.86 RTRV-SYNCN: Retrieve SYNCN

11.11.87 RTRV-T1: Retrieve T1

11.11.88 RTRV-T3: Retrieve T3

11.11.89 RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.90 RTRV-TOD: Retrieve Time of Day

11.11.91 SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

11.11.92 SET-TOD: Set Time of Day

11.11.93 SW-DX-EQPT: Switch DX Equipment

11.12 Access Identifiers

11.12.1 bits

11.12.2 ds-1

11.12.3 env

11.12.4 eqpt

11.12.5 facility

11.12.6 sts

11.12.7 syn_src

11.12.8 sync_ref

11.12.9 vt1_5

11.13 Parameter Types

11.13.1 ATAG Description

11.13.2 CTAG Description

11.13.3 TID Description

11.13.4 ALL_MONTYPE

11.13.5 ALL_THR

11.13.6 CCT

11.13.7 COND_EFF

11.13.8 CONDITION

11.13.9 DIRECTION

11.13.10 DS3_FMT

11.13.11 DS_LINE_CODE

11.13.12 DS_LINE_TYPE

11.13.13 DX_MODE_OP

11.13.14 E_LBO

11.13.15 ENV_ALM

11.13.16 ENV_CTL

11.13.17 EQPT_TYPE

11.13.18 EQUIP

11.13.19 EQUIPMENT_TYPE

11.13.20 EXT_RING

11.13.21 FRAME_FORMAT

11.13.22 LINE_BUILDOUT

11.13.23 LINE_CODE

11.13.24 LOCATION

11.13.25 LPBK_TYPE

11.13.26 MOD2

11.13.27 MOD2ALM

11.13.28 MOD2B

11.13.29 MODIFIER

11.13.30 NOTIF_CODE

11.13.31 OCN_MONTYPE

11.13.32 OCN_TYPE

11.13.33 ON_OFF

11.13.34 OPTICAL_MODE

11.13.35 PRIVILEGE

11.13.36 PROT_MOD_OP

11.13.37 PROTECTION_GROUP

11.13.38 PST

11.13.39 REVERTIVE_TIME

11.13.40 REVERTIVE_TYPE

11.13.41 RNG_TYPE

11.13.42 SD_BER

11.13.43 SDCC_MODE

11.13.44 SERV_EFF

11.13.45 SF_BER

11.13.46 SIDE

11.13.47 STATE

11.13.48 STATUS

11.13.49 STM_TYPE

11.13.50 STS_MONTYPE

11.13.51 STS_PATH

11.13.52 SWITCH

11.13.53 SYNC_GENERATION

11.13.54 SYNC_MODE

11.13.55 SYNC_QUALITY_LEVEL

11.13.56 TIMING_MODE

11.13.57 TMG_REF

11.13.58 TMPR

11.13.59 USE_DST

11.13.60 VALIDITY

11.13.61 Performance Monitoring Parameters by Line Type

11.14 Errors

11.15 Echo


11

TL1 Reference


11.1 Overview

This section lists TL1 alarms, commands, and autonomous messages supported by the Cisco ONS 15454. For more information about TL1, refer to Telcordia document GR833-CORE, Network Maintenance: Network Element and Transport Surveillance Messages.

11.2 Craft Interface

The TCC/TCC+ has two built-in interface ports for accessing the ONS 15454. With one RJ-45 craft interface browser LAN connection you can access the system using a standard browser interface. While using the browser interface, you can perform local and remote Operations, Administration, Maintenance and Provisioning (OAM&P) functions and open a VT100 emulation window to enter TL1 commands. If a browser is not available, you can access the system using a nine- pin RS-232 port. The RS-232 port supports VT100 emulation such that TL1 commands may be entered directly without a browser.

Refer to the "Craft Interface Installation" section on page 1-31 for detailed installation procedures. Refer to the "Connecting to the ONS 15454 with TL1 Terminals" section on page 3-9 for information on terminal setup.

11.3 TL1 Access using Telnet

To access the ONS 15454 TL1 commands using a Telnet session over a craft interface or a Local Access Network (LAN) connection (TCC/TCC+ front panel or backplane pins), you must use port number 2361. At a command prompt, start the Telnet session by typing:

telnet <Node IP Address> 2361 [Enter]

11.4 Alarms

This section lists TL1 alarms supported by the ONS 15454. Each alarm list includes a description, service affect criteria, and severity. Refer to Chapter 9, "CTC Alarms," for fault recovery procedures. The following alarm types are listed:

Equipment Alarms

SONET Optical Carrier, level n (OC-N) Alarms

Digital Signal, level 1 (DS-1) Alarms

Digital Signal, level 3 (DS-3) Alarms

Synchronous Transport Signal (STS) Alarms

Virtual Tributary (VT) Termination Alarms

Building Integrated Timing Supply (BITS) Alarms

Network Element (NE) Synchronous Reference Alarms

11.4.1 Equipment Alarms

Table 11-1 Equipment Alarms 

EQPT alarm
Card/Mode
Severity (Active/ Standby)
SA/NSA (Active/ Standby)
Description

INT

all

any mode

CR/MN

SA/NSA

Internal board Failure

IMPROPRMVL

all

any mode

CR/MN

SA/NSA

Board is provisioned and has been unplugged

MEA

all

any mode

MN/MN

NSA/NSA

Mismatch in between the physical equipment type and the provisioned equipment type

FAILTOSW-
PATH

TCC,TCC+,XC,DS-3

any mode

MJ/MN

SA/NSA

Failure to perform an equipment protection switch

POWERFAIL

all

any mode

CR/MN

NSA/NSA

Power Failure on the node

MANUAL

TCC,TCC+,XC,DS-3

any mode

MN/MN

NSA/NSA

Operator Manual switch severity active

FORCED

TCC,TCC+,XC,DS-3

any mode

MN/MN

NSA/NSA

Operator Force switch severity active

DIAGFAIL

all

any mode

CR/MN

NSA/NSA

Equipment diagnostic failure

HITEMP

TCC,TCC+

Any mode

CR/CR

NSA/NSA

Excessive temperature - operating still maintaining normal operations

FAN

all

any mode

CR/MI

NSA/NSA

Fan operation failure

PWRRESTART

all

any mode

MI/MI

NSA/NSA

Power restart

AUTORESET

all

any mode

MI/MI

NSA/NSA

Automatic reset

MANRESET

TCC,TCC+

any mode

MI/MI

NSA/NSA

Manual reset

INIT

TCC,TCC+

any mod

MI/MI

NSA/NSA

Initialization initiated

SWTRANSFER

TCC,TCC+

any mod

MI/MI

NSA/NSA

Software download in progress

CONTBUS-A-X

IO,XC

any mode

MJ/MN

NSA/NSA

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot X

CONTBUS-A-8

IO,XC

any mode

MJ/MN

NSA/NSA

Main processor on the TCC/TCC+ card in Slot 7 has lost communication with the coprocessor on the second TCC/TCC+ card in Slot 11

CONTBUS-B-X

IO,XC

any mode

MJ/MN

NSA/NSA

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot X

CONTBUS-B-8

IO,XC

any mode

MJ/MN

NSA/NSA

Main processor on the TCC/TCC+ card in Slot 11 has lost communication with the processor on the second TCC/TCC+ card in Slot 7

CTNEQPT-PBXPROT

I/O,
XC/XCVT

CR/MN

SA/NSA

Failure of the main payload between the XC/XCVT card in Slot 10 and the reporting I/O card in Slot X

CTNEQPT-PBXWORK

I/O,
XC/XCVT

CR/MN

SA/NSA

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot X


11.4.2 OC-N Alarms

Table 11-2 OC-N Alarms 

OC-n alarm
Card/Mode
Severity (Active/
Standby)
SA/NSA
(Active/
Standby)
Description

LOS

OC-3, OC-12, OC-48

any mode

CR/MN

SA/NSA

Loss of Signal alarm

LOF

OC-3,OC-12, OC-48

any mode

CR/MN

SA/NSA

Loss of Frame alarm

AIS-L

OC-3,OC-12,
OC-48

any mode

MN/MN

SA/NSA

Alarm Indication Signal Line alarm

RFI-L

OC-3,OC-12,
OC-48

any mode

MN/MN

NSA/NSA

Remote Failure Indication Line alarm

SFBER

OC-3,OC-12,
OC-48,

any mode

CR/MN

SA/NSA

Signal fail error rate alarm

SDBER

OC-3,OC-12,
OC-48

any mode

MN/MN

SA/NSA

Signal degrade error rate alarm

FAILTOSW-RNG

OC-3,OC-12,
OC-48

2F BLSR mode

MJ/MN

SA/NSA

Failure to perform a two-fiber BLSR ring switch

FAILTOSW-SPAN

OC-3,OC-12,
OC-48

linear mode

MJ/MN

SA/NSA

Failure to perform a Linear APS 1+1 switch

MANUAL-REQ

OC-3,OC-12,
OC-482

2F BLSR mode

MN/MN

NSA/NSA

Manual Ring Switch Severity active

FORCED-REQ

OC-3,OC-12,
OC-48

2F BLSR mode

MN/MN

SA/NSA

Force Ring Switch Severity active

LOCKOUTOFPR-
RING

OC-3,OC-12,
OC-482

2F BLSR mode

MN/MN

SA/NSA

Lockout of Protection Channel Switch Severity active

MANUAL-SPAN

OC-3,OC-12,
OC-48

linear mode

MN/MN

NSA/NSA

Manual Span Switch Severity active

FORCED-SPAN

OC-3,OC-12,
OC-482

linear mode

MN/MN

SA/NSA

Force Span switch Severity active

LOCKOUT-SPAN

OC-3,OC-12,
OC-48

linear mode

MN/MN

SA/NSA

Lockout Span Switch Severity active

APSB

OC-3,OC-12,
OC-48

linear mode

MJ/MN

SA/NSA

Automatic Protection Switching (APS) byte failure

APSCM

OC-3,OC-12,
OC-48

linear mode

MJ/MN

SA/NSA

APS Channel Mismatch failure

APSMM

OC-3,OC-12,
OC-48

linear mode

MJ/MN

SA/NSA

APS Mode Mismatch failure

APSFERPFAIL

 

MN/MN

NSA/NSA

APS channel far-end protection line failure

EOC

 

MJ/MN

NSA/NSA

Data communication channel failure

SQUELCH

OC-12,OC-48

2F BLSR mode

MJ/MN

SA/NSA

Squelching in progress

INCON

OC-12,OC-48

2F BLSR mode

MJ/MN

SA/NSA

Inconsistent APS code

APSCIMP

OC-12,OC-48

2F BLSR mode

MJ/MN

SA/NSA

Improper SONET Automatic Protect Switch code

NODEMIS

OC-12,OC-48

2F BLSR mode

MJ/MN

SA/NSA

Node Id mismatch failure

DFLTK

OC-12,OC-48

2F BLSR mode

MN/MN

NSA/NSA

Default K byte transmitted

CONNLOS

TCC/TCC+

2F BLSR mode

MJ/MN

NSA/NSA

Inter-node connectivity lost in two-fiber BLSR configuration

ALS

 

CR/MN

NSA/NSA

Automatic laser shut down

LPBKTERMIN

OC-3,OC-12,
OC-48

any mode

MJ/MI

SA/NSA

Terminal loopback active

LPBKFACILITY

OC-3, OC-12, OC-48

any mode

MJ/MI

SA/NSA

Facility loopback active


11.4.3 DS-3 Alarms

Table 11-3 DS-3 Alarms 

DS-3 alarm
Card/Mode
Severity (Active)
SA/NSA (Active)
Description

PEERMISSM

DS-3

any mode

MJ

SA

Peer state mismatch

LOS

DS-3

any mode

CR

SA

Loss of signal alarm

LPBK

DS-3

any mode

MJ

SA

Loopback active

IDLE

DS-3

any mode

MJ

SA

DS-3 idle condition

RAI

DS-3

any mode

MN

SA

Remote alarm indication

DS3MANTERM- LPBK

DS-3

any mode

MJ

SA

Loopback terminal

DS3MANFAC
LPBK

DS-3

any mode

MJ

SA

Loopback facility

DS3FELPBK

DS-3

any mode

MJ

SA

Loopback due to Far-End Alarm Condition (FEAC) command

DS2FELPBK

DS-3

any mode

MJ

SA

DS-2 loopback command sent to far-end

DS1FELPBK

DS-3

any mode

MJ

SA

DS- 1 loopback due to FEAC command

DS3FELPBK

DS-3

any mode

MJ

SA

DS-3 loopback due to FEAC command

DS3FELPBKCMD

DS-3

any mode

MJ

SA

DS-3 loopback command sent to far-end

FE-EQPT-FAIL-SA

DS-3

any mode

MJ

SA

Far-end DS-3 equipment fail service-affecting

FE-LOS

DS-3

any mode

MJ

SA

Far-end loss of signal

FE-LOF

DS-3

any mode

MJ

SA

Far-end loss of frame

FE-AIS

DS-3

any mode

MJ

SA

Far-end alarm indication signal

FE-IDLE

DS-3

any mode

MJ

SA

Far-end idle

FE-EQPT-NSA

DS-3

any mode

MJ

SA

Far-end DS-3 equipment fail non-service affecting

DS3FECMNEQPT

FAIL

DS-3

any mode

MJ

SA

Far-end common equipment fail non-service affecting

FE-DS1-MULTI
LOS

DS3XM

any mode

MJ

SA

Far-end multiple DS-1 LOS detected on DS-3

DS1FEEQPTFAIL
SA

DS3XM

any mode

MJ

SA

Far-end DS-1 equipment fail service-affecting

FE-SD1-SNGLLOS

DS3XM

any mode

MJ

SA

DS-1 far-end single DS-1 LOS

DS1FEEQPT

DS3XM

any mode

MJ

SA

Far-end DS-1 equipment failure service-affecting


11.4.4 DS-1 Alarms

Table 11-4 DS-1 Alarms

DS-1 alarm
Card/Mode
Severity (Active/ Standby)
SA/NSA (Active/ Standby)
Description

LOS

DS-1

any mode

MJ/None

SA/None

Loss of signal alarm

AIS

DS-1

any mode

MJ/None

SA/None

Alarm indication signal alarm

LOF

DS-1

any mode

MJ/None

SA/None

Loss of frame alarm

RAI

DS-1

any mode

MN/None

SA/None

Remote alarm indication alarm

TERMLPBK

DS-1

any mode

MJ/None

SA/None

Terminal loopback active

FACLPBK

DS-1

any mode

MJ/None

SA/None

Facility loopback active

ELECTRICAL INTERFACE MISSING - TX

DS-1

any mode

MJ/MN

NSA/NSA

Facility Termination equipment - Transmitter missing

ELECTRICAL INTERFACE MISSING - RX

DS-1

any mode

MJ/MN

NSA/NSA

Facility Termination equipment - Receiver missing

ELECTRICAL INTERFACE FAILURE - TX

DS-1

any mode

MJ/MN

NSA/NSA

Transmit Failure

FELPBK

DS-1

any mode

MJ/None

SA/None

DS-1 loopback due to FEAC command

FELPBKCMD

DS-1

any mode

MJ/None

SA/None

DS-1 loopback command sent to far-end


11.4.5 STS Alarms

Table 11-5 STS Alarms

STS Mon alarm
Card/Mode
Severity (Active/ Standby)
SA/NSA (Active/ Standby)
Description

AIS-P

STS Monitor

any mode

MJ/MN

SA/NSA

Alarm Indication Signal alarm

LOP

STS Monitor

any mode

MJ/MN

SA/NSA

Loss of Pointer alarm

CONCAT

STS Monitor

any mode

MJ/MN

SA/NSA

STS concatenation alarm

UNEQ-P

STS Termination on DS-3 card any mode

MJ/MN

SA/NSA

Path Unequipped alarm

SFBER

STS Termination on DS-3 card

any mode

MJ/MN

SA/NSA

Path Signal Fail bit error rate alarm

SDBER

STS Termination on DS-3 card

any mode

MN/MN

SA/NSA

Path Signal Degrade bit error rate alarm

RFI

STS Termination on DS-3 card

any mode

MN/MN

SA/NSA

Path Remote Failure Indication alarm

SLMF

STS Termination on DS-3 card

any mode

MN/MN

SA/NSA

Signal Label Mismatch alarm

PDI-P

 

MN/MN

SA/NSA

Payload Defect Indication Path

PLM-P

 

MN/MN

SA/NSA

Payload Label Mismatch Path

FAILTOSW

STS Termination on DS-3 card

any mode

MJ/MN

NSA/NSA

Fail to switch to protection

MANUAL

STS Termination on DS-3 card

any mode

MN/MN

NSA/NSA

Manual switch of working facility equipment to protection

FORCED

STS Termination on DS-3 card

any mode

MN/MN

NSA/NSA

Working facility/equipment forced to switch to protection


11.4.6 VT Termination Alarms

Table 11-6 VT Termination Alarms

VT Term alarm
Card/Mode
Severity
(Active/
Standby)
SA/NSA
(Active/
Standby)
Description

LOP

STS Monitor any mode

MJ/MN

SA/NSA

Loss of pointer alarm

AIS

VT Termination on DS-1 card any mode

MJ/MN

SA/NSA

VT Alarm Indication Signal alarm

UNEQP

VT
Termination on DS-1 card any mode

MJ/MN

SA/NSA

VT Unequipped alarm

RFI

VT Termination on DS-1 card any mode

MN/MN

SA/NSA

VT Remote Failure Indication alarm

PLM

VT Termination on DS-1 card any mode

MN/MN

SA/NSA

VT Payload Label Mismatch alarm

SFBER

 

MJ/MN

SA/NSA

BER threshold passed for signal failure

SDBER

 

MJ/MN

SA/NSA

BER threshold passed for signal degrade


11.4.7 BITS Alarms

Table 11-7 Bits Alarms

BITS alarm
Card/Mode
Severity (Active/ Standby)
SA/NSA (Active/ Standby)
Description

LOS

Bits on

TCC/TCC+ card any mode

MJ/MN

SA/NSA

Loss of Signal alarm

LOF

Bits on

TCC/TCC+ card any mode

MJ/MN

SA/NSA

Loss of Frame alarm

AIS

Bits on

TCC/TCC+ card any mode

MJ/MN

SA/NSA

Alarm Indication Signal alarm


11.4.8 Network Element Synch Ref Alarms

Table 11-8 Synch Ref Alarms

neSynchRef alarm
Card/Mode
Severity (Active/ Standby)
SA/NSA
Description

SYNCPRI

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Primary Synchronization reference failure alarm

SYNCSEC

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Secondary Synchronization reference failure alarm

SYNCTHIRD

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Third Synchronization reference failure alarm

HLDOVRSYNC

neSynchRef on

TCC/TCC+ card any mode

MJ/MN

SA/NSA

Holdover Synchronization alarm

FRNGSYNC

neSynchRef on

TCC/TCC+ card any mode

MJ/MN

SA/NSA

Free Run Synchronization alarm

MANUAL

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Operator-initiated synchronization switch

FASTSTART

Fast start

Synch node

No

No Alarm

Fast Start Synchronization alarm

MANSWTOPRI

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to primary reference

MANSWTOSEC

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to second reference

MANSWTOTHID

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to third reference

SWTOPRI

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to primary reference

SWTOSEC

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to second reference

SWTOTHIRD

neSynchRef on

TCC/TCC+ card any mode

MN/MN

NSA/NSA

Synchronization switch to third reference


11.5 Autonomous Messages

The autonomous TL1 messages are included in the TL1 Command Description section, and the messages are listed alphabetically. Figure 11-1 shows the autonomous alarm message format. Autonomous Message Tag (ATAG) is used for message sequencing. The number is incremented by one for each autonomous message sent by the ONS 15454. The ONS 15454 uses whole numbers 0000 to 9999.

Figure 11-1 Autonomous Alarm Message Format

11.6 Performance Monitoring

Performance information is continuously monitored and stored in individual Performance Monitoring (PM) registers. This information can be retrieved upon request or when a preset threshold is exceeded. lists PM Statistics by board.

11.6.1 Performance Monitoring Statistics

Table 11-9 PM Statistics 

PM Statistics by Board
Special Qualifications
Source
DS-1
DS-3
DS-3 XM
OC-3/12/48
EC-1

Sonet Section Stats

             

CV-S

(not supported yet)

B1

         

ES-S

(not supported yet)

B1

         

SES-S

(not supported yet)

B1

         

SEFS-S

 

B1

     

X

X

Sonet Line Stats

             

CV-L

 

B2

     

X

X

ES-L

 

B2

     

X

X

SES-L

         

X

X

UAS-L

         

X

X

FC-L

         

X

X

PSC

         

X

 

PSD

         

X

 

STS PJ

Non-terminated STS only

H1, H2

         

PPJC-PDET

Positive detected at input

       

X

X

NPJC-PDET

Negative detected at input

       

X

X

PPJC-PGEN

Positive generated

       

X

X

NPJC-PGEN

Negative generated

       

X

X

Far End

             

CV-L FE

 

K2

     

X

X

ES-L FE

 

K2

     

X

X

SES-L FE

 

K2

     

X

X

UAS-L FE

 

K2

     

X

X

FC-L FE

 

K2

     

X

X

Sonet Path Stats

             

CV-P

 

B3

X

X

X

   

ES-P

   

X

X

X

   

SES-P

   

X

X

X

   

UAS-P

   

X

X

X

   

FC-P

             

VT PJ

             

Far End

Supplied by XCON

           

CV-P FE

From XCON

       

X

 

ES-P FE

From XCON

       

X

 

SES-P FE

From XCON

       

X

 

UAS-P FE

From XCON

       

X

 

FC-P FE

             

VT Path Stats

VT terminated circuits only

           

CV-V

   

X

 

X

   

ES-V

   

X

 

X

   

SES-V

   

X

 

X

   

UAS-V

   

X

 

X

   

FC-V

             

Far End

             

CV-V FE

   

X

 

X

   

ES-V FE

   

X

 

X

   

SES-V FE

   

X

 

X

   

UAS-V FE

   

X

 

X

   

FC-V FE

             

DS-n Stats

             

DS-n Line

             

CV-L

 

X

X

X

X

   

ES-L

 

X

X

X

X

   

LOSS-L

       

X

   

SES-L

 

X

X

X

X

   

DS-3 Path

             

P Bit Stats

M13 & C Bit Framing

           

AISS-P

       

X

   

CVP-0

       

X

   

ESP-P

       

X

   

SASP-P

       

X

   

SESP-P

       

X

   

UASP-P

       

X

   

CP Bit Stats

C Bit Framing ONLY

           

CVCP-P

       

X

   

ESCP-P

       

X

   

SASCP-P

       

X

   

SESCP-P

       

X

   

UASCP-P

       

X

   

Far End

             

CVCP-P FE

       

X

   

ESCP-P FE

       

X

   

SASCP-P FE

       

X

   

SESCP-P FE

       

X

   

UASCP-P FE

       

X

   

DS-1 Path

             

CV-P RX

   

X

       

AISS-P RX

   

X

 

X

   

ES-P RX

   

X

 

X

   

SAS-P RX

   

X

 

X

   

SES-P RX

   

X

 

X

   

UAS-P RX

   

X

 

X

   

CV-P TX

   

X

 

X

   

AISS-P TX

   

X

 

X

   

ES-P TX

   

X

 

X

   

SAS-P TX

   

X

 

X

   

SES-P TX

   

X

 

X

   

UAS-P TX

   

X

 

X

   

11.7 TL1 Command Syntax

TL1 commands conform to the following syntax:

a:b:c::d:e: ... z;

where:

"a" is the Command Code

"b" is the Target Identifier (TID)

"c" is the Access Identifier (AID) or the User Identifier (UID)

"d" is the Correlation Tag (CTAG)

"e: ... z;" are the other positions required for various commands

The TID, AID, and CTAG route and control the TL1 command. Other parameters provide additional messages required to complete the action requested by the command.

The TID is a unique name given to each system when it is installed. The name identifies the particular NE (in this case, the ONS 15454), to which each command is directed. Each TID can have a maximum of 20 alpha-numeric characters. To establish the TID for a ONS 15454 node, use the Network Element Name option of the Network Element Configuration menu.

The AID is an access code used to identify and address specific objects within the ONS 15454. These objects include individual pieces of equipment, transport spans, access tributaries, and other objects.

The CTAG is a unique identifier given to each input command by the operator. When the ONS 15454 system responds to a specific command, it includes the command's CTAG in the reply. This eliminates discrepancies about what response corresponds to what command. Valid CTAG values include strings of up to six characters comprised of identifiers (alphanumeric, beginning with a letter) or decimal numerals (a string of decimal digits with an optional non-trailing ".").

11.8 TL1 Command Privilege Map

The following table specifies command access privileges.

Table 11-10 Command Access

Command
Superuser
Provision
Maintenance
Retrieve

DLT-USER-SECU

X

     

ED-DAT

X

     

ED-USER-SECU

X

     

ENT-USER-SECU

X

     

SET-TOD

X

X

   

DLT-*-*

X

X

   

ED-*-*

X

X

   

ENT-*-*

X

X

   

SET-*-*

X

X

   

INIT-*-*

X

X

X

 

OPR-*-*

X

X

X

 

RLS-*-*

X

X

X

 

RMV-*-*

X

X

X

 

RST-*-*

X

X

X

 

SW-*-*

X

X

X

 

ALW-*-*

X

X

X

X

INH-*-*

X

X

X

X

REPT * *

X

X

X

X

RTRV-*-*

X

X

X

X

CANC-*-*

X

X

X

X

ACT-*-*

X

X

X

X

ED-PD

X

X

X

X


User security levels also limit the amount of time a user can leave the system idle before the TL1 session is locked to prevent unauthorized users from making changes. Higher security levels have shorter idle times. shows security levels and their idle times

Table 11-11 Security Idle Times 

Security Level
Idle Time

Retrieve

Unlimited

Maintenance

60 minutes

Provision

30 minutes

Superuser

15 minutes


11.9 TL1 Command List

11.9.1 Cross Connect

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

11.9.2 Environment

REPT ALM ENV

RTRV-ALM-ENV

11.9.3 Equipment

DLT-EQPT

DLT-FFP-EQPT

ED-FFP-EQPT

ENT-EQPT

ENT-FFP-EQPT

OPR-PROTNSW-EQPT

REPT ALM EQPT

REPT EVT EQPT

RLS-PROTNSW-EQPT

RTRV-ALM-EQPT

RTRV-COND-EQPT

RTRV-EQPT

RTRV-FFP-EQPT

SW-DX-EQPT

11.9.4 Facility

RMV-<MOD2>

RST-<MOD2>

11.9.5 Facility Protection

DLT-FFP-<OCN_TYPE>

ED-FFP-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

RTRV-FFP-<OCN_TYPE>

11.9.6 Fault

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT EVT <MOD2ALM>

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

11.9.7 Log

RTRV-LOG

11.9.8 Performance

INIT-REG-<MOD2>

RTRV-PM-<MOD2>

RTRV-TH-<MOD2>

SET-TH-<MOD2>

11.9.9 Security

DLT-USER-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

11.9.10 Switch

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

11.9.11 Synchronization

ED-SYNCN

REPT ALM SYNCN

REPT EVT SYNCN

RTRV-ALM-SYNCN

RTRV-COND-SYNCN

RTRV-SYNCN

11.9.12 System

ACT-USER

ALW-MSG-ALL

CANC-USER

ED-DAT

INH-MSG-ALL

INIT-SYS

RTRV-HDR

11.9.13 Testing

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

11.9.14 Other

DLT-<MODE2>

ED-<OCN_TYPE>

ED-<STS_PATH>

ED-BITS

ED-EC1

ED-NE

ED-T1

ED-T3

ENT-<MOD2>

OPR-UPGRADE

RTRV-<OCN_TYPE>

RTRV-<STS_PATH>

RTRV-BITS

RTRV-EC1

RTRV-INV

RTRV-NE

RTRV-T1

RTRV-T3

RTRV-TOD

SET-TOD

11.10 TL1 Command Index

Table 11-12 Command Index 

Command
Group
Page Number

ACT-USER

System

ACT-USER: Activate User

ALW-MSG-ALL

System

ALW-MSG-ALL: Allow Message All

CANC-USER

System

CANC-USER: Cancel User

DLT-<MODE2>

Other

DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

DLT-CRS-<STS_PATH>

Cross Connect

DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)

DLT-CRS-VT1

Cross Connect

DLT-CRS-VT1: Delete Cross Connect Virtual Tributary

DLT-EQPT

Equipment

DLT-EQPT: Delete Equipment

DLT-FFP-<OCN_TYPE>

Facility Protection

DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)

DLT-FFP-EQPT

Equipment

DLT-FFP-EQPT: Delete Facilities Protection Equipment

DLT-USER-SECU

Security

DLT-USER-SECU: Delete User Security

ED-<OCN_TYPE>

Other

ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)

ED-<STS_PATH>

Other

ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)

ED-BITS

Other

ED-BITS: Edit Building Integrated Timing Supply

ED-CRS-<STS_PATH>

Cross Connect

ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)

ED-CRS-VT1

Cross Connect

ED-CRS-VT1: Edit Cross Connect Virtual Tributary

ED-DAT

System

ED-DAT: Edit Date and Time

ED-EC1

Other

ED-EC1: Edit Electrical Carrier Level 1

ED-FFP-<OCN_TYPE>

Facility Protection

ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)

ED-FFP-EQPT

Equipment

ED-FFP-EQPT: Edit Equipment Protection

ED-NE

Other

ED-NE: Edit Network Element

ED-PID

Security

ED-PID: Edit Private Identifier

ED-SYNCN

Synchronization

ED-SYNCN: Edit Synchronization

ED-T1

Other

ED-T1: Edit T1

ED-T3

Other

ED-T3: Edit T3

ED-USER-SECU

Security

ED-USER-SECU: Edit User Security

ENT-<MOD2>

Other

ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

ENT-CRS-<STS_PATH>

Other

ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)

ENT-CRS-VT1

Other

ENT-CRS-VT1: Enter Cross Connect Virtual Tributary

ENT-EQPT

Equipment

ENT-EQPT: Enter Equipment

ENT-FFP-<OCN_TYPE>

Facility Protection

ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)

ENT-FFP-EQPT

Equipment

ENT-FFP-EQPT: Enter Equipment Protection

ENT-USER-SECU

Security

ENT-USER-SECU: Enter User Security

INH-MSG-ALL

System

INH-MSG-ALL: Inhibit Message All

INIT-REG-<MOD2>

Performance

INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

INIT-SYS

System

INIT-SYS: Initialize System

OPR-LPBK-<OCN_TYPE>

Testing

OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)

OPR-LPBK-DS1

Testing

OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1

OPR-LPBK-EC1

Testing

OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1

OPR-LPBK-T1

Testing

OPR-LPBK-T1: Operate Loopback T1

OPR-LPBK-T3

Testing

OPR-LPBK-T3: Operate Loopback T3

OPR-PROTNSW-<OCN_TYPE>

Switch

OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)

OPR-PROTNSW-EQPT

Equipment

OPR-PROTNSW-EQPT: Operate Protection Switch Equipment

OPR-UPGRADE

Other

OPR-UPGRADE: Operate Upgrade

REPT ALM <MOD2ALM>

Fault

REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

REPT ALM BITS

Fault

REPT ALM BITS: Report Alarm Building Integrated Timing Supply

REPT ALM ENV

Environment

REPT ALM ENV: Report Alarm Environment

REPT ALM EQPT

Equipment

REPT ALM EQPT: Report Alarm Equipment

REPT ALM SYNCN

Synchronization

REPT ALM SYNCN: Report Alarm Synchronization

REPT EVT <MOD2ALM>

Fault

REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

REPT EVT EQPT

Equipment

REPT EVT EQPT: Report Event Equipment

REPT EVT SYNCN

Synchronization

REPT EVT SYNCN: Report Event Synchronization

RLS-LPBK-<OCN_TYPE>

Testing

RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)

RLS-LPBK-DS1

Testing

RLS-LPBK-DS1: Release Loopback Digital Signal Level 1

RLS-LPBK-EC1

Testing

RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1

RLS-LPBK-T1

Testing

RLS-LPBK-T1: Release Loopback T1 Facility

RLS-LPBK-T3

Testing

RLS-LPBK-T3: Release Loopback T3 Facility

RLS-PROTNSW-<OCN_TYPE>

Switch

RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)

RLS-PROTNSW-EQPT

Equipment

RLS-PROTNSW-EQPT: Release Protection Switch Equipment

RMV-<MOD2>

Facility

RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

RST-<MOD2>

Facility

RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

RTRV-<OCN_TYPE>

Other

RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)

RTRV-<STS_PATH>

Other

RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)

RTRV-ALM-<MOD2ALM>

Fault

RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)

RTRV-ALM-ALL

Fault

RTRV-ALM-ALL: Retrieve Alarm All

RTRV-ALM-BITS

Fault

RTRV-BITS: Retrieve Building Integrated Timing Supply

RTRV-ALM-ENV

Environment

RTRV-ALM-ENV: Retrieve Alarm Environment

RTRV-ALM-EQPT

Equipment

RTRV-ALM-EQPT: Retrieve Alarm Equipment

RTRV-ALM-SYNCN

Synchronization

RTRV-ALM-SYNCN: Retrieve Alarm Synchronization

RTRV-BITS

Other

RTRV-BITS: Retrieve Building Integrated Timing Supply

RTRV-COND-<MOD2ALM>

Fault

RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

RTRV-COND-ALL

Fault

RTRV-COND-ALL: Retrieve Condition All

RTRV-COND-BITS

Fault

RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply

RTRV-COND-EQPT

Equipment

RTRV-COND-EQPT: Retrieve Condition Equipment

RTRV-COND-SYNCN

Synchronization

RTRV-COND-SYNCN: Retrieve Condition Synchronization

RTRV-CRS-<STS_PATH>

Cross Connect

RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)

RTRV-CRS-VT1

Cross Connect

RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary

RTRV-EC1

Other

RTRV-EC1: Retrieve Electrical Carrier Level 1

RTRV-EQPT

Equipment

RTRV-EQPT: Retrieve Equipment

RTRV-FFP-<OCN_TYPE>

Facility Protection

RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)

RTRV-FFP-EQPT

Equipment

RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment

RTRV-HDR

System

RTRV-HDR: Retrieve Header

RTRV-INV

Other

RTRV-INV: Retrieve Inventory

RTRV-LOG

Log

RTRV-LOG: Retrieve Log

RTRV-NE

Other

RTRV-NE: Retrieve Network Element

RTRV-PM-<MOD2>

Performance

RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

RTRV-SYNCN

Synchronization

RTRV-SYNCN: Retrieve SYNCN

RTRV-T1

Other

RTRV-T1: Retrieve T1

RTRV-T3

Other

RTRV-T3: Retrieve T3

RTRV-TH-<MOD2>

Performance

RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

RTRV-TOD

Other

RTRV-TOD: Retrieve Time of Day

SET-TH-<MOD2>

Performance

SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

SET-TOD

Other

SET-TOD: Set Time of Day

SW-DX-EQPT

Equipment

SW-DX-EQPT: Switch DX Equipment


11.11 TL1 Command Description

This section lists TL1 commands supported by the ONS 15454. Each listing includes a description, input format, input parameters (instructions within a command), and input example. The descriptions are alphabetical according to the first alpha character of the command string.


Note   The TL1 input command string size should equal and less than 1023 characters from either a TL1 telnet session or CTC. Any TL1 input string larger than 1023 characters will cause the active TCC to reset.



Note   TL1 commands not entered correctly are not completed.


11.11.1 ACT-USER: Activate User

This command allows you to log in to the Network Element (NE).

Section
Description 

Category

System

Security

Read Only

Related Messages

ALW-MSG-ALL

CANC-USER

DLT-USER-SECU

ED-DAT

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-ALL

INIT-SYS

RTRV-HDR

Input Format

ACT-USER:[TID]:<userid>:[CTAG]::<passwd>;

where:

userid identifies the user to the system and is a String

passwd is the user's private password and is a String

Example

Input

ACT-USER:PETALUMA:TERRI:100::MYPASSWD;

Errors

This message generates all the default errors


11.11.2 ALW-MSG-ALL: Allow Message All

This command instructs the NE to enter a mode in which all automatic messages are transmitted.

Section
Description 

Category

System

Security

N/A

Related Messages

ACT-USER

CANC-USER

ED-DAT

INH-MSG-ALL

INIT-SYS

RTRV-HDR

Input Format

ALW-MSG-ALL:[TID]::[CTAG]::,,;

Example

Input

ALW-MSG-ALL:PETALUMA::549::,,;

Errors

This message generates all the default errors


11.11.3 CANC-USER: Cancel User

This command logs a user off of the NE.

Section
Description 

Category

System

Security

Read Only

Related Messages

ACT-USER

ALW-MSG-ALL

DLT-USER-SECU

ED-DAT

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-ALL

INIT-SYS

RTRV-HDR

Input Format

CANC-USER:[TID]:[<userid>]:[CTAG];

where:

userid identifies the user to the system and is a String

Example

Input

CANC-USER:PETALUMA:TERRI:101;

Errors

This message generates all the default errors


11.11.4 DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command deletes the line or facility by putting it out of service.


Note   The DLT- does not support STS1, STS3C, STS12C, STS48C, VT1, and DS1 modifiers in Release 2.2.1.


Section
Description 

Category

Other

Security

N/A

Related Messages

N/A

Input Format

DLT-<MOD2>:[TID]:<aid>:[CTAG];

where:

aid is the AID ALL

Example

Input

DLT-EC1:CISCO:FAC-1-1:123;

Errors

This message generates all the default errors


11.11.5 DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)

This command deletes a cross-connect between STS paths. STS paths are specified using their STS AID.

Section
Description 

Category

Cross Connect

Security

N/A

Related Messages

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

Input Format

DLT-CRS-<STS_PATH>:[TID]:<from>,<to>:[CTAG]:::;

where:

from is the source aid of the cross sts connection and is the AID sts

to is the destination aid of the crs sts connection and is the AID sts

Example

Input

DLT-CRS-STS12C:VINBURG:STS-1-1, STS-12-1:102:::;

Errors

This message generates all the default errors


11.11.6 DLT-CRS-VT1: Delete Cross Connect Virtual Tributary

This command deletes the VT1 cross connects.

Section
Description 

Category

Cross Connect

Security

N/A

Related Messages

DLT-CRS-<STS_PATH>

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

Input Format

DLT-CRS-VT1:[TID]:<from>,<to>:[CTAG]:::;

where:

from is the source aid of the vt connection and is the AID vt1_5

to is the destination aid of the crs vt connection and is the AID vt1_5

Example

Input

DLT-CRS-VT1:CISCO:VT1-2-3-1,VT1-4-4-1:1234:::;

Errors

This message generates all the default errors


11.11.7 DLT-EQPT: Delete Equipment

This command deletes a card from the NE. It removes the card type and attributes that were entered for a particular slot. If any facilities are assigned, they are also deleted as long as they do not contain any cross-connect end-points, the cards are not in a protection group and they are not in SDCC termination. If any of the above descriptions exist, the command will be denied.

Section
Description 

Category

Equipment

Security

N/A

Related Messages

DLT-FFP-EQPT RLS-PROTNSW-EQPT

ED-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

DLT-EQPT:[TID]:<eqpt_aid>:[CTAG];

where:

equip_aid is the AID eqpt

Example

Input

DLT-EQPT:SONOMA:SLOT-1:104;

Errors

This message generates all the default errors


11.11.8 DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)

This command deletes a linear protected group on optical cards.

Section
Description 

Category

Facility Protection

Security

N/A

Related Messages

N/A

Input Format

DLT-FFP-<OCN_TYPE>:[TID]:<work>,<protect>:[CTAG];

where:

work is the working equipment and the AID facility

protect is the protection equipment and the AID facility

Example

Input

DLT-FFP-OC3:PETALUMA:FAC-2-1,FAC-1-1:1;

Errors

This message generates all the default errors


11.11.9 DLT-FFP-EQPT: Delete Facilities Protection Equipment

This command deletes an equipment protection group.

Section
Description 

Category

Equipment

Security

N/A

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

ED-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

DLT-FFP-EQPT:[TID]:<work>,<protect>:[CTAG];

where:

work is the AID eqpt

protect is the AID eqpt

Example

Input

DLT-FFP-EQPT:PETALUMA:SLOT-2,SLOT-1:1;

Errors

This message generates all the default errors


11.11.10 DLT-USER-SECU: Delete User Security

This command removes a user and can only be used by an administrator. The AID block contains the user identifier. If this command is executed while the user is logged on, the current session for that user continues. Once the user logs out, the same userid cannot be used to log in again. This command is defined in TR-835.

Section
Description 

Category

Security

Security

Admin

Related Messages

ACT-USER

CANC-USER

ED-PID

ED-USER-SECU

ENT-USER-SECU

Input Format

DLT-USER-SECU:[TID]:<username>:[CTAG];

where:

username is a String

Example

Input

DLT-USER-SECU:CISCO:UID:123;

Errors

This message generates all the default errors


11.11.11 ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)

This command modifies the attributes (i.e. service parameters) and state of an OC-N facility. Allowable states for a facility are Out of Service (OOS) and In Service (IS).

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

ED-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::[SDCC=<sdcc>],
[PJMON=<pjmon>],[SFBER=<sfber>],[SDBER=<sdber>],
[MODE=<opticalMode>]:[<pst>]:;

Note   If changing the pst field only, use the following Input Format:

ED-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::[<pst>]:;

where:

fac_aid is the AID facility

sdcc enables the Section DCC for this facility and is of type SDCC_MODE

pjmon is the number of the STS facility to monitor for pointer justifications pjmon is an Integer

sfber is of type SF_BER

sdber is of type SD_BER

opticalMode is of type OPTICAL_MODE

pst is the card primary state and is of type PST

Example

Input

ED-OC48:PENNGROVE:FAC-6-1:114::SDCC=Y,PJMON=48,SFBER=1E-4,
SDBER=1E-6, MODE=SONET:IS:;

Errors

This message generates all the default errors


11.11.12 ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)

This command is used to modify the attributes associated with an STS path.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

ED-<STS_PATH>:[TID]:<sts_aid>:[CTAG]::[SFBER=[<sfber>],
[SDBER=<sdber>]::;

where:

sts_aid is the AID sts

sfber is of type SF_BER

sdber is of type SD_BER

Example

Input

ED-STS1:FERNDALE:STS-2-4:115::SFBER=1E-3,SDBER=1E-5::;

Errors

This message generates all the default errors


11.11.13 ED-BITS: Edit Building Integrated Timing Supply

This command modifies BITS reference attributes.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

ED-BITS:[TID]:<bits_aid>:[CTAG]::[LNCDE=<line_code>],
[FRMF=<frame_format>]:<pst>:;

where:

bits_aid is the AID bits

line_code is the BITS line code and is of type LINE_CODE

frame_format is the BITS frame format and is of type FRAME_FORMAT

pst is the BITS state and is of type PST

Example

Input

ED-BITS:SONOMA:BITS-2:779::LNCDE=AMI,FRMF=ESF:IS;

Errors

This message generates all the default errors


11.11.14 ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)

This command modifies attributes of an STS-level cross-connect. Under certain circumstances, you may change the cross-connect type (e.g. from 1WAY to 2WAY).

Section
Description 

Category

Cross Connect

Security

Read/Write

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

Input Format

ED-CRS-<STS_PATH>:[TID]:<from>,<dst>:[CTAG]::<cct>::;

where:

from is the source aid of the cross sts connection and is the AID sts

dst is the AID sts

cct is the cross connection type and is of type CCT

Example

Input

ED-CRS-STS3C:KENWOOD:STS-6-4,STS-12-7:108::2WAY::;

Errors

This message generates all the default errors


11.11.15 ED-CRS-VT1: Edit Cross Connect Virtual Tributary

This command edits the VT1.5 cross-connect.

Section
Description 

Category

Cross Connect

Security

Read/Write

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

Input Format

ED-CRS-VT1:[TID]:<from>,<to>:[CTAG]::<cct>::;

where:

from is the AID vtl_5

to is the AID vtl_5

cct is the cross connection type and is of type CCT

Example

Input

ED-CRS-VT1:CISCO:VT1-2-1-1,VT1-4-1-1:1234::1WAY::;

Errors

This message generates all the default errors


11.11.16 ED-DAT: Edit Date and Time

This command edits the date and time.

Section
Description 

Category

System

Security

Read/Write

Related Messages

ACT-USER

ALW-MSG-ALL

CANC-USER

INH-MSG-ALL

INIT-SYS

RTRV-HDR

Input Format

ED-DAT:[TID]::[CTAG]::[<date>],[<time>];

where:

date is the date field YYYY-MM-DD or YY-MM-DD; date is a String

time is the time field HH-MM-SS, the hours 0..24; time is a String

Example

Input

ED-DAT:TID::1234::99-12-21,14-35-15;

Errors

This message generates all the default errors


11.11.17 ED-EC1: Edit Electrical Carrier Level 1

This command edits EC-1 facilities. This command will edit the properties of an EC-1 card port.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

ED-EC1:[TID]:<fac>:[CTAG]::[PJMON=<pjmon>][,][LBO=<lbo>]:<pst>:;

where:

fac is the facility aid. fac is the AID facility

pjmon is the SONET pointer number 0 or 1 and is an Integer

lbo is the line buildout and is of type E_LBO

pst is the port state and is of type PST

Example

Input

ED-EC1:CISCO:FAC-1-1:123::PJMON=0,LBO=0-225:IS:;

Errors

This message generates all the default errors


11.11.18 ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)

This command edits the optical facility protection.

Section
Description 

Category

Facility Protection

Security

Read/Write

Related Messages

N/A

Input Format

ED-FFP-<OCN_TYPE>:[TID]:<facility>:[CTAG]::[NAME=<name>],
[RVTT=<revertiveType>],[RVTM=<revertiveTime>],[BSWM=<bswMode>];

where:

facility is the facility aid and is the AID facility

name is the protection name and is a String

revertiveType is of type REVERTIVE_TYPE

revertiveTime is of type REVERTIVE_TIME

bswMode specifies if it is a bidirectional switch mode and is of type ON_OFF

Example

Input

ED-FFP-OC3:PETALUMA:FAC-1-1:1::NAME=PROT_NAME,RVTT=R,
RVTM=1.0,BSWM=OFF;

Errors

This message generates all the default errors


11.11.19 ED-FFP-EQPT: Edit Equipment Protection

This command edits an equipment protection group.

Section
Description 

Category

Equipment

Security

Read/Write

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

ED-FFP-EQPT:[TID]:<eqpt>:[CTAG]::[NAME=<name>],
[RVTT=<revertiveType>],[RVTM=<revertiveTime>];

where:

eqpt is the equipment aid and is the AID eqpt

name is the name of the group and is a String

revertiveType is of type REVERTIVE_TYPE

revertiveTime is of type REVERTIVE_TIME

Example

Input

ED-FFP-EQPT:PETALUMA:SLOT-1:1::NAME=PROT_NAME,RVTT=R,
RVTM=1.0;

Errors

This message generates all the default errors


11.11.20 ED-NE: Edit Network Element

This command modifies the attributes of the NE system such as changing the node's identity (e.g. IP address), external interfaces (e.g. LAN ports), and major modes of operation (e.g. SONET vs. SDH).

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

ED-NE:[TID]::[CTAG]:::[NAME=<name>],[IPADDR=<ipaddr>],
[IPMASK=<ipmask>],[DEFRTR=<defrtr>],[TMMD=<timing_mode>],
[SSMG=<sync_gen>],[NSQL=<sync_quality_level>];

where:

name is the System Identifier (SID/TID) of the NE and must be 20 characters or less; name is a String

ipaddr is the IP address of the NE on the local LAN and is a String

ipmask is the IP Mask used to identify the sub-net on which the NE resides; ipmask is a String

defrtr is the IP address of the default router and is a String

timing_mode is of type TIMING_MODE

sync_gen is of type SYNC_GENERATION

sync_quality_level is of type SYNC_QUALITY_LEVEL

Example

Input

ED-NE:LKVLL::111:::NAME=LAKEVILLE,IPADDR=192.168.100.52,
IPMASK=255.255.255.0,DEFRTR=192.168.100.1,TMMD=LINE,
SSMG=GEN1,NSQL=ABOVE-PRS;

Errors

This message generates all the default errors


11.11.21 ED-PID: Edit Private Identifier

This command allows a user to change their own password. Other user identification and access changes may only be made by a superuser. This command is defined in TR-835.


Note   The password cannot be null. It will be echoed as clear text as the message is parsed and only after the complete message is entered and terminated.



Note   The password should not appear in the TL1 log on the NE.


Section
Description 

Category

Security

Security

Read/Write

Related Messages

ACT-USER

CANC-USER

DLT-USER-SECU

ED-USER-SECU

ENT-USER-SECU

Input Format

ED-PID:[TID]:<username>:[CTAG]::<oldPassword>,<newPassword>;

where:

username is a String

oldPassword is a String

newPassword is a String

Example

Input

ED-PID:CISCO:UID:123::OLD_PASSWORD,NEW_PASSWORD;

Errors

This message generates all the default errors


11.11.22 ED-SYNCN: Edit Synchronization

This command modifies the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources may be specified (for example, PRIMARY, SECOND, THIRD).

Section
Description 

Category

Synchronization

Security

Read/Write

Related Messages

REPT ALM SYNCN

REPT EVT SYNCN

RTRV-ALM-SYNCN

RTRV-COND-SYNCN

RTRV-SYNCN

Input Format

ED-SYNCN:[TID]:<sync_aid>:[CTAG]:::[PRIMARY=<primary>],
[SECOND=<second>],[THIRD=<third>]:;

where:

sync_aid is the synchronization reference to be modified; sync_aid is the AID sync_ref and is listable

primary is the AID syn_src

second is the AID syn_src

third is the AID syn_src

Example

Input

ED-SYNCN:BOYES:SYNC-NE:112:::PRIMARY=INTERNAL,
SECOND=INTERNAL,THIRD=INTERNAL:;

Errors

This message generates all the default errors


11.11.23 ED-T1: Edit T1

This command modifies the attributes related to a DS-1 port.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

ED-T3

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-T1

RLS-LPBK-T3

RTRV-T1

RTRV-T3

Input Format

ED-T1:[TID]:<tl1_aid>:[CTAG]::[ID=<id>],[LNCDE=<line_code>],
[FRMF=<frame_format>],[LBO=<line_buildout>]:[<pst>]:;

where:

t1_aid is the AID facility

id is a String

line_code is the port line code and is of type LINE_CODE

frame_format is of type FRAME_FORMAT

line_buildout is the port line buildout and is of type LINE_BUILDOUT

pst is of type PST

Example

Input

ED-T1:CISCO:FAC-1-1:1223::ID=CISCO,LNCDE=AMI,FRMF=ESF,
LBO=0-131:IS:;

Errors

This message generates all the default errors


11.11.24 ED-T3: Edit T3

This command edits a DS-3 and DS-3 transmux card.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

ED-T1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-T1

RLS-LPBK-T3

RTRV-T1

RTRV-T3

Input Format

ED-T3:[TID]:<facility>:[CTAG]::[LNTYPE=<lineType>],
[LNCODE=<lineCode>],[LB0=<lbo>][<pst>];

where:

facility is the AID facility

lineType is the port line type and is of type DS_LINE_TYPE

lineCode is the line code and is the lineCode of the DS3XM card; lineCode is of type DS_LINE_CODE

lbo is the circuit line buildout and is of type E_LBO

pst is of type PST

Example

Input

ED-T3:CISCO:FAC-1-2:123::LNTYPE=C-BIT,LNCODE=B3ZS,LBO=0-225:
IS:;

Errors

This message generates all the default errors


11.11.25 ED-USER-SECU: Edit User Security

This command edits a user's privileges, password, or ID. Only a user with R/W admin privileges may perform this operation. Privilege levels are described in the ENT-USER-SECU: Enter User Security command. This command is defined in TR-835.


Note   If the password is changed with this command, the password should be blanked out in the TL1 log.


Section
Description 

Category

Security

Security

Admin

Related Messages

ACT-USER

CANC-USER

DLT-USER-SECU

ED-PID

ENT-USER-SECU

Input Format

ED-USER-SECU:[TID]:<username>:[CTAG]::[PASSWORD=<password>],
[PRIVILEGE=<privilege>];

where:

username is a String

password is a String

privilege is of type PRIVILEGE

Example

Input

ED-USER-SECU:CISCO:UID:123::PASSWORD=PASSWORD,
PRIVILEGE=MAINT;

Errors

This message generates all the default errors


11.11.26 ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command puts a facility or an aid in service.


Note   ENT-DS1/STS1/STS3C/STS12C/STS48C/VT1 are not supported in Release 2.2.1.


Section
Description 

Category

Other

Security

Admin

Related Messages

N/A

Input Format

ENT-<MOD2>:[TID]:<aid>:[CTAG];

where:

aid is the aid to be put in service and is the AID ALL

Example

Input

ENT-OC3:CISCO:FAC-1-1:1243;

Errors

This message generates all the default errors


11.11.27 ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)

This command creates an STS cross-connect between two or more STS paths. Rather than create each individual unidirectional connection singularly, this command accepts cross-connection types (CCT) that identify aggregate cross-connects based on their function in the network. To enter a cross-connect, the facilities that support the STS paths must be either in service or out of service assigned. If a cross-connect (XC) card is not present in the system or if the paths have incompatible payload types, the request is denied.

Section
Description 

Category

Cross Connect

Security

Admin

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

RTRV-CRS-VT1

Input Format

ENT-CRS-<STS_PATH>:[TID]:<from>,<to>:[CTAG]::<cct>::;

where:

from is the source aid of the cross sts connection and is the AID sts

to is the destination aid of the crs sts connection and is the AID sts

cct is the cross connection type and is of type CCT

Example

Input

ENT-CRS-STS1:BODEGA:STS-1-5,STS-2-5:116::2WAY::;

Errors

This message generates all the default errors


11.11.28 ENT-CRS-VT1: Enter Cross Connect Virtual Tributary

This command creates a VT1 cross connect.

Section
Description 

Category

Cross Connect

Security

Admin

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

RTRV-CRS-<STS_PATH}>

RTRV-CRS-VT1

Input Format

ENT-CRS-VT1:[TID]:<from>,<to>:[CTAG]::<cct>::;

where:

from is the source aid of the cross vt connection and is the AID vt1_5

to is the destination aid of the crs vt connection and is the AID vt1_5

cct is the cross connection type and is of type CCT

Example

Input

ENT-CRS-VT1:CISCO:VT1-2-3-14,VT1-4-4-12:1234::1WAY::;

Errors

This message generates all the default errors


11.11.29 ENT-EQPT: Enter Equipment

This command enters the card type and attributes for a given equipment slot in the NE. It also automatically enters all facilities supported by the card, assigning default values to all facility and path attributes.

Section
Description 

Category

Equipment

Security

Admin

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-EQPT

ED-FFP-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

ENT-EQPT:[TID]:<eqpt>:[CTAG]::<eqpt_type>;

where:

eqpt is the AID eqpt

eqpt_type is of type EQUIPMENT_TYPE

Example

Input

ENT-EQPT:PETALUMA:SLOT-12:118::OC12;

Errors

This message generates all the default errors


11.11.30 ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)

This command creates an optical protection.

Section
Description 

Category

Facility Protection

Security

Admin

Related Messages

N/A

Input Format

ENT-FFP-<OCN_TYPE>:[TID]:<work>,<protect>:[CTAG]::[NAME=<name>],
[RVTM=<rvtm>],[RVTT=<rvtt>],[BSWM=<bswMode>];

where:

work is the working unit aid and is the AID facility

protect is the protection unit aid and is the AID facility

name is the protection name and is a String

rvtm is the revertive mode and is of type REVERTIVE_TYPE

rvtt is the revertive time and of type REVERTIVE_TIME

bswMode specifies if it is bidirectional switch mode and is of type ON_OFF

Example

Input

ENT-FFP-OC3:PETALUMA:FAC-2-1,FAC-1-1:1::NAME=PROT_NAME,
RVTM=R,RVTT=1.0,BSWM=OFF;

Errors

This message generates all the default errors


11.11.31 ENT-FFP-EQPT: Enter Equipment Protection

This command creates an equipment protection.

Section
Description 

Category

Equipment

Security

Admin

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-EQPT

ED-FFP-EQPT RTRV-COND-EQPT

ENT-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

ENT-FFP-EQPT:[TID]:<work>,<protect>:[CTAG]::PRT=<protectionGroup>,
[NAME=<name>],[RVTM=<rvtm>],[RVTT=<rvtt>];

where:

work is the AID eqpt

protect is the AID eqpt

protectionGroup is the protection group 1-1 or 1-N and is of type PROTECTION_GROUP

name is the protection name and is a String

rvtm is the revertive mode and is of type REVERTIVE_TYPE

rvtt is the revertive time and is of type REVERTIVE_TIME

Example

Input

ENT-FFP-EQPT:PETALUMA:SLOT-2,SLOT-1:1::PRT=1-1,
NAME=PROT_NAME,RVTM=R,RVTT=1.0;

Errors

This message generates all the default errors


11.11.32 ENT-USER-SECU: Enter User Security

This command adds a user account. Only administrators may do this. The AID block contains the user identifier. See .

There are seven security levels defined for the TalonMX. Each user may be configured as possessing 1or more of these seven privileges.

1 Read-Only Alarms: Users possessing this security level can retrieve and receive autonomous alarms.

2 Read-Write Alarms: Users possessing this security level can manage as well as receive/retrieve alarm information.

3 Read-Only Provisioning: Users possessing this security level can retrieve TalonMX provisioning values.

4 Read-Write Provisioning: Users possessing this security level can set/retrieve TalonMX provisioning values.

5 Read-Only Administrative: Users possessing this security level can retrieve TalonMX security settings.

6 Read-Write Administrative: Users possessing this security level can set/retrieve TalonMX security settings.

7 Read-Write Maintenance: Users possessing this security level can perform maintenance functions such as operating/releasing loopbacks.

A superuser will have all privileges shown above.

This command is defined in TR-835.

Section
Description 

Category

Security

Security

Admin

Related Messages

ACT-USER

CANC-USER

DLT-USER-SECU

ED-PID

ED-USER-SECU

Input Format

ENT-USER-SECU:[TID]:<username>:[CTAG]::<password>,<privilege>;

where:

username is a String

password is the user login password and is a String

privilege is the user security level and is of type PRIVILEGE; Superuser=super, Provision=prov, Maintenance=maint, Retrieve=rtrv

Example

Input

ENT-USER-SECU:CISCO:UID:123::PSWD,MAINT;

Errors

This message generates all the default errors


11.11.33 INH-MSG-ALL: Inhibit Message All

This command instructs the NE to enter a mode that prevents all automatic messages from being transmitted.

Section
Description 

Category

System

Security

N/A

Related Messages

ACT-USER

ALW-MSG-ALL

CANC-USER

ED-DAT

INIT-SYS

RTRV-HDR

Input Format

INH-MSG-ALL:[TID]::[CTAG]::,,;

Example

Input

INH-MSG-ALL:PETALUMA::550::,,;

Errors

This message generates all the default errors


11.11.34 INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command initializes the performance monitoring registers.

Section
Description 

Category

Performance

Security

Read/Write

Related Messages

RTRV-PM-<MOD2>

RTRV-TH-<MOD2>

SET-TH-<MOD2>

Input Format

INIT-REG-<MOD2>:[TID]:<aid>:[CTAG]::,,,,<tmpr>,,;

where:

aid is the AID facility

tmpr is of type TMPR

Example

Input

INIT-REG-OC3:TID:FAC-1-1:1234::,,,,15MIN,,;

Errors

This message generates all the default errors


11.11.35 INIT-SYS: Initialize System

This command instructs the NE to initialize the specified card and its associated subsystem(s). The command supports various levels of restart, called phases, ranging from a warm start to a cold start.


Note   In Release 2.2.1 this command only resets equipment. The phase parameter is not supported in this release.


Section
Description 

Category

System

Security

Read/Write

Related Messages

ACT-USER

ALW-MSG-ALL

CANC-USER

ED-DAT

INH-MSG-ALL

RTRV-HDR

Input Format

INIT-SYS:[TID]:<eqpt_aid>:[CTAG]::[<phase>];

where:

eqpt-aid is the AID eqpt

phase is the level of initialization to take place; the higher the number the stronger the reset, A phase=1 is a warm start and A phase=10 is a cold start; phase is an Integer

Example

Input

INIT-SYS:HOTWATER:SLOT-1:201::3;

Errors

This message generates all the default errors


11.11.36 OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)

This command instructs the NE to operate a loopback on a specified OC-N facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

OPR-LPBK-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::,,,,<lpbktype>;

where:

fac_aid is the AID facility

lpbktype identifies the type of loopback (Terminal or Facility) to be established and is of type LPBK_TYPE

Example

Input

OPR-LPBK-OC3:PTREYES:FAC-5-12:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.37 OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1

This command operates a DS-1 signal loopback on a DS3XM-6 card.


Note   The TERMINAL loopback type is not supported for this command.


Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

OPR-LPBK-DS1:[TID]:<ds>:[CTAG]::,,,<lpbkType>;

where:

ds is the aid for the DS3XM card on the ds-1 and is the AID ds-1

lpbkType is the loop back type

Note   The terminal loop back type is not supported for the DS3XM in Release 2.2.1. lpbkType is of type LPBK_TYPE

Example

Input

OPR-LPBK-DS1:PTREYES:DS1-4-2-13:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.38 OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1

This command operates the loopback on an EC-1 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

OPR-LPBK-EC1:[TID]:<facility>:[CTAG]::,,,<lpbkType>;

where:

facility is the facility aid for the EC-1 and is the AID facility

lpbkType is the loop back type and is of type LPBK_TYPE

Example

Input

OPR-LPBK-EC1:PTREYES:FAC-4-2:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.39 OPR-LPBK-T1: Operate Loopback T1

This command operates the loopback for a DS-1 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

ED-T1

ED-T3

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

RTRV-T1

RTRV-T3

Input Format

OPR-LPBK-T1:[TID]:<fac>:[CTAG]::,,,<lpbk_type>;

where:

fac is the AID facility

lpbk_type is the loop back type for the DS-1 cards and is of type LPBK_TYPE

Example

Input

OPR-LPBK-T1:PTREYES:FAC-4-12:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.40 OPR-LPBK-T3: Operate Loopback T3

This command instructs the NE to operate a loopback on a specified T3 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

ED-T1 RLS-LPBK-DS1

ED-T3 RLS-LPBK-EC1

OPR-LPBK-<OCN_TYPE> RLS-LPBK-T1

OPR-LPBK-DS1 RLS-LPBK-T3

OPR-LPBK-EC1 RTRV-T1

OPR-LPBK-T1 RTRV-T3

RLS-LPBK-<OCN_TYPE>

Input Format

OPR-LPBK-T3:[TID]:<fac_aid>:[CTAG]::,,,<lpbktype>;

where:

fac_aid is the AID facility

lpbktype identifies the loopback type (Terminal or Facility) to be established and is of type LPBK_TYPE

Example

Input

OPR-LPBK-T3:SCHELLVILLE:FAC-2-11:202::,,,TERMINAL;

Errors

This message generates all the default errors


11.11.41 OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)

This command instructs the NE to initiate a SONET line protection switch request. User switch requests initiated with this command remain active until they are released via the RLS-PROTNSW-OCN command or are overridden by a higher priority protection switch request.

Section
Description 

Category

Switch

Security

Read/Write

Related Messages

N/A

Input Format

OPR-PROTNSW-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::<dnField>;

where:

fac_aid is the AID facility and is listable

dnField is the switch mode and is of type SWITCH

Example

Input

OPR-PROTNSW-OC48:CHICKALUMA:FAC-2-1:204::LOCKOUT;

Errors

This message generates all the default errors


11.11.42 OPR-PROTNSW-EQPT: Operate Protection Switch Equipment

This command initiates a protection switch. The RLS-PROTNSW-EQPT command can be used to release a switch condition.

Section
Description 

Category

Equipment

Security

Read/Write

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-EQPT

ED-FFP-EQPT RTRV-COND-EQPT

ENT-EQPT RTRV-EQPT

ENT-FFP-EQPT RTRV-FFP-EQPT

REPT ALM EQPT SW-DX-EQPT

REPT EVT EQPT

Input Format

OPR-PROTNSW-EQPT:[TID]:<eqpt_aid>:[CTAG]::<sc>;

where:

eqpt_aid is the equipment aid and is the AID eqpt

sc is the protection switch mode and is of type PROT_MOD_OP

Example

Input

OPR-PROTNSW-EQPT:LASLOMAS:SLOT-1:205::FRCD;

Errors

This message generates all the default errors


11.11.43 OPR-UPGRADE: Operate Upgrade

This command operates upgrades.

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

OPR-UPGRADE:[TID]:<eqpt_aid>:[CTAG];

where:

eqpt_aid is the AID eqpt

Example

Input

OPR-UPGRADE:FOUNTAINGROVE:SLOT-1:204;

Errors

This message generates all the default errors


11.11.44 REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

Reports an alarm condition against a facility or a line.


Note   The STS alarms are reported as STS1 alarms.


Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM BITS RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-ENV

REPT ALM EQPT RTRV-ALM-EQPT

REPT ALM SYNCN RTRV-ALM-SYNCN

REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT EVT EQPT RTRV-COND-ALL

REPT EVT SYNCN RTRV-COND-BITS

RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT

RTRV-ALM-ALL RTRV-COND-SYNCN

Output Format

SID DATE TIME
** ATAG REPT ALM <MOD2ALM>
"<ds1Aid>:<ntfcncde>,<condition>,<srveff>,,,,:[<desc>],<eqptType>"
;

where:

ds1aid is the AID ds1

ntfcncde is the 2-letter notification code and is of type NOTIF_CODE

condition is of type CONDITION

srveff is the effect on service caused by the alarm condition; srveff is of type SERV_EFF.

desc is a String

eqptType is of type EQPT_TYPE

Example

Output

TID-000 98-06-20 14-30-00
** 001 REPT ALM DS1
"DS1-14-3-5:MJ,LPBKFACILITY,SA,,,,:\"LOOP BACK ACTIVE\",
DS3XM-6"
;


11.11.45 REPT ALM BITS: Report Alarm Building Integrated Timing Supply

Reports an alarm condition on a BITS facility.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-ENV

REPT ALM EQPT RTRV-ALM-EQPT

REPT ALM SYNCN RTRV-ALM-SYNCN

REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT EVT EQPT RTRV-COND-ALL

REPT EVT SYNCN RTRV-COND-BITS

RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT

RTRV-ALM-ALL RTRV-COND-SYNCN

Output Format

SID DATE TIME
** ATAG REPT ALM BITS
"<bits_aid>:<ntfcncde>,<condition>,<srveff>,,,,:[<desc>]"
;

where:

bits_aid is the AID bits

ntfcncde is the 2-letter notification code and is of type NOTIF_CODE

condition is a type of alarm condition and is of type CONDITION

srveff is the effect on service caused by the alarm condition; srveff is of type SERV_EFF

desc is a String

Example

Output

TID-000 98-06-20 14-30-00
** 001 REPT ALM BITS
"BITS-1:MJ,SYNC,SA,,,,:\"LOSS OF TIMING\","
;


11.11.46 REPT ALM ENV: Report Alarm Environment

Reports a customer-defined condition on an environmental alarm input.

Section
Description 

Category

Environment

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM BITS RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

RTRV-ALM-ALL

Output Format

SID DATE TIME
** ATAG REPT ALM ENV
"<env_aid>:<ntfcnnde>,<almtype>,,,<desc>"
;

where:

env_aid is AID env

ntfcncde is of type NOTIF_CODE

almtype is of type ENV_ALM

desc is a String

Example

Output

TID-000 98-06-20 14-30-00
** 001 REPT ALM ENV
"ENV-IN-1:MJ,OPENDR,,,\"OPEN DOOR\""
;

Errors

This message generates all the default errors


11.11.47 REPT ALM EQPT: Report Alarm Equipment

Reports an alarm condition against an equipment unit or slot.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT RTRV-ALM-<MOD2ALM>

DLT-FFP-EQPT RTRV-ALM-ALL

ED-FFP-EQPT RTRV-ALM-BITS

ENT-EQPT RTRV-ALM-ENV

ENT-FFP-EQPT RTRV-ALM-EQPT

OPR-PROTNSW-EQPT RTRV-ALM-SYNCN

REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT ALM BITS RTRV-COND-ALL

REPT ALM ENV RTRV-COND-BITS

REPT ALM SYNCN RTRV-COND-EQPT

REPT EVT <MOD2ALM> RTRV-COND-SYNCN

REPT EVT EQPT RTRV-EQPT

REPT EVT SYNCN RTRV-FFP-EQPT

RLS-PROTNSW-EQPT SW-DX-EQPT

Output Format

SID DATE TIME
** ATAG REPT ALM EQPT
"<eqpt>:<ntfcncde>,<condition>,<srveff>,,,,,<desc>,<eqptType>"
;

where:

eqpt is the equipment aid SLOT-{1-17} and is the AID eqpt

ntfcncde is the 2-letter notification code and is of type NOTIF_CODE

condition is the type of alarm condition and is of type CONDITION

srveff is the effect on service caused by the alarm condition and is of type SERV_EFF

desc is a String

eqptType is of type EQPT_TYPE

Example

Output

TID-000 98-06-20 14-30-00
** 001 REPT ALM EQPT
"SLOT-7:MN,CONTR,NSA,,,,:\"CONTROLLER FAILURE\",TCC"
;


11.11.48 REPT ALM SYNCN: Report Alarm Synchronization

Reports an alarm condition against a synchronization reference.

Section
Description 

Category

Synchronization

Security

Read Only

Related Messages

ED-SYNCN RTRV-ALM-BITS

REPT ALM <MOD2ALM> RTRV-ALM-ENV

REPT ALM BITS RTRV-ALM-EQPT

REPT ALM ENV RTRV-ALM-SYNCN

REPT ALM EQPT RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

RTRV-ALM-ALL RTRV-SYNCN

Output Format

SID DATE TIME
** ATAG REPT ALM SYNCN
"<sync_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>"
;

where:

sync_aid is the identifier of Synchronization Reference with alarm condition; sync_aid is the AID sync_ref

ntfcncde is the 2-letter notification code and is of type NOTIF_CODE

condition is the type of alarm condition and is of type CONDITION

srveff is the effect on service caused by the alarm condition and is of type SERV_EFF

desc is a String

Example

Output

TID-000 98-06-20 14-30-00
** 001 REPT ALM SYNCN
"SYNC-NE:MJ,MAN,SA,,,,:\"MANUAL SWITCH\","
;


11.11.49 REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

Reports the occurrence of a non-alarmed event.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM BITS RTRV-ALM-ENV

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT EQPT RTRV-COND-ALL

REPT EVT SYNCN RTRV-COND-BITS

RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT

RTRV-ALM-ALL RTRV-COND-SYNCN

Output Format

SID DATE TIME
A ATAG REPT EVT <MOD2ALM>
"<fac_aid>:<condition>,[<condeff>],,,[<location>],,[<monval>],
[<th_val>],[<tmpr>]:<desc>,<eqptType>"
;

where:

fac_aid is the identifier of the OC-N facility with the condition and is the AID facility

condition is of type CONDITION

condeff is the effect of the condition on the NE; condeff is of type COND_EFF and is optional

location is of type LOCATION and is optional

monval is the monitored value and is optional

th_val is the threshold value; th_val is an Integer and is optional

tmpr is the time period; tmpr is of type TMPR and is optional

desc is a String

eqptType is of type EQPT_TYPE

Example

Output

TID-000 98-06-20 14-30-00
A 001 REPT EVT T3
"FAC-4-1:WKSWPR,TC,,,FEND,,12,13,15MIN:\"WORKING SWITCH TO
PROTECTION\",DS3-12"
;


11.11.50 REPT EVT EQPT: Report Event Equipment

Reports the occurrence of a non-alarmed event against an equipment unit or slot.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT RTRV-ALM-<MOD2ALM>

DLT-FFP-EQPT RTRV-ALM-ALL

ED-FFP-EQPT RTRV-ALM-BITS

ENT-EQPT RTRV-ALM-ENV

ENT-FFP-EQPT RTRV-ALM-EQPT

OPR-PROTNSW-EQPT RTRV-ALM-SYNCN

REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT ALM BITS RTRV-COND-ALL

REPT ALM ENV RTRV-COND-BITS

REPT ALM EQPT RTRV-COND-EQPT

REPT ALM SYNCN RTRV-COND-SYNCN

REPT EVT <MOD2ALM> RTRV-EQPT

REPT EVT SYNCN RTRV-FFP-EQPT

RLS-PROTNSW-EQPT SW-DX-EQPT

Output Format

SID DATE TIME
A ATAG REPT EVT EQPT
"<eqpt>:<condition>,<condeff>,<eqptType>,,,,,:[<desc>]"
;

where:

eqpt is the slot number of the equipment and is the AID eqpt

condition is the type of event and is of type CONDITION

condeff is the effect of the condition on the NE; condeff is of type COND_EFF

eqptType is the equipment type and is of type EQPT_TYPE

desc is a String

Example

Output

TID-000 98-06-20 14-30-00
A 001 REPT EVT EQPT
"SLOT-7:,PLUGIN,TC,TCC,,,,,:\"EQUIPMENT PLUG-IN\","
;


11.11.51 REPT EVT SYNCN: Report Event Synchronization

Reports the occurrence of a non-alarmed event against a synchronization entity.

Section
Description 

Category

Synchronization

Security

Read Only

Related Messages

ED-SYNCN RTRV-ALM-BITS

REPT ALM <MOD2ALM> RTRV-ALM-ENV

REPT ALM BITS RTRV-ALM-EQPT

REPT ALM ENV RTRV-ALM-SYNCN

REPT ALM EQPT RTRV-COND-<MOD2ALM>

REPT ALM SYNCN RTRV-COND-ALL

REPT EVT <MOD2ALM> RTRV-COND-BITS

REPT EVT EQPT RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

RTRV-ALM-ALL RTRV-SYNCN

Output Format

SID DATE TIME
A ATAG REPT EVT SYNCN
"<sync_aid>:<condition>,<condeff>,,,,,,:[<desc>]"
;

where:

sync_aid is the identifier of the synchronization entity with the condition; sync_aid is the AID sync_ref

condition is of type CONDITION

condeff is of type COND_EFF

desc is a String

Example

Output

TID-000 98-06-20 14-30-00
A 001 REPT EVT SYNCN
"SYNC-NE:SWTOINT,SC,,,,,,:\"SWITCH TO INTERNAL CLOCK\","
;


11.11.52 RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)

This command instructs the NE to release a loopback on the specified OC-N facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

RLS-LPBK-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::,,,[<lpbktype>];

where:

fac_aid is the AID facility

lpbktype is the type of loopback to be released and is of type LPBK_TYPE

Example

Input

RLS-LPBK-OC3:PTREYES:FAC-12-1:208::,,,FACILITY;

Errors

This message generates all the default errors


11.11.53 RLS-LPBK-DS1: Release Loopback Digital Signal Level 1

This command releases a DS-1 signal loopback for the DS3XM-6 card.


Note   The TERMINAL loopback is not supported.


Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-EC1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

RLS-LPBK-DS1:[TID]:<ds1Aid>:[CTAG]::,,,[<lpbkType>];

where:

ds1Aid is the AID ds1

lpbkType is of type LPBK_TYPE

Example

Input

RLS-LPBK-DS1:PTREYES:DS1-4-2-13:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.54 RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1

This command releases loopback for an EC-1 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-T1

RLS-LPBK-T3

Input Format

RLS-LPBK-EC1:[TID]:<facility>:[CTAG]::,,,<lpbkType>;

where:

facility is the AID facility

lpbkType is of type LPBK_TYPE

Example

Input

RLS-LPBK-EC1:PTREYES:FAC-3-12:203::,,,FACILITY;

Errors

This message generates all the default errors


11.11.55 RLS-LPBK-T1: Release Loopback T1 Facility

This command instructs the NE to release the loopback for the T1 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

ED-T1

ED-T3

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T3

RTRV-T1

RTRV-T3

Input Format

RLS-LPBK-T1:[TID]:<fac>:[CTAG]::,,,[<lpbk_type>];

where:

fac releases the loopback for a T1 facility. fac is the AID facility.

lpbk_type is of type LPBK_TYPE.

Example

Input

RLS-LPBK-T1:PTREYES:FAC-1-12:203::,,,FACILITY;

Errors

This message generates all of the Default Errors.


11.11.56 RLS-LPBK-T3: Release Loopback T3 Facility

This command instructs the NE to release a loopback on the specified T3 facility.

Section
Description 

Category

Testing

Security

Read/Write

Related Messages

ED-T1

ED-T3

OPR-LPBK-<OCN_TYPE>

OPR-LPBK-DS1

OPR-LPBK-EC1

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-<OCN_TYPE>

RLS-LPBK-DS1

RLS-LPBK-EC1

RLS-LPBK-T1

RTRV-T1

RTRV-T3

Input Format

RLS-LPBK-T3:[TID]:<fac_aid>:[CTAG]::,,,[<lpbk_type>];

where:

fac_aid is the AID facility

lpbktype is the type of loopback to be released; lpbktype is of type LPBK_TYPE.

Example

Input

RLS-LPBK-T3:SCHELLVILLE:FAC-6-11:207::,,,TERMINAL;

Errors

This message generates all the default errors


11.11.57 RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)

Instructs the NE to release a line protection switch request between a working line and a protection line.

Section
Description 

Category

Switch

Security

Read/Write

Related Messages

N/A

Input Format

RLS-PROTNSW-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG];

where:

fac_aid is the AID facility

Example

Input

RLS-PROTNSW-OC48:CHICKALUMA:FAC-6-1:209;

Errors

This message generates all the default errors


11.11.58 RLS-PROTNSW-EQPT: Release Protection Switch Equipment

This command instructs the NE to release a protection switch on an equipment unit.

Section
Description 

Category

Equipment

Security

Read/Write

Related Messages

DLT-EQPT REPT EVT EQPT

DLT-FFP-EQPT RTRV-ALM-EQPT

ED-FFP-EQPT RTRV-COND-EQPT

ENT-EQPT RTRV-EQPT

ENT-FFP-EQPT RTRV-FFP-EQPT

OPR-PROTNSW-EQPT SW-DX-EQPT

REPT ALM EQPT

Input Format

RLS-PROTNSW-EQPT:[TID]:<eqpt_aid>:[CTAG];

where:

eqpt_aid is the AID eqpt

Example

Input

RLS-PROTNSW-EQPT:LASLOMAS:SLOT-3:401;

Errors

This message generates all the default errors


11.11.59 RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command removes a facility from an in service state to out of service.


Note   RMV-DS1/STS1/STS3C/STS12C/STS48C/VT1 are not supported in Release 2.2.1.


Section
Description 

Category

Facility

Security

N/A

Related Messages

N/A

Input Format

RMV-<MOD2>:[TID]:<facility>:[CTAG];

where:

facility is the AID facility

Example

Input

RMV-EC1:CISCO:FAC-1-1:1234;

Errors

This message generates all the default errors


11.11.60 RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command provisions a facility in service.

Section
Description 

Category

Facility

Security

N/A

Related Messages

N/A

Input Format

RST-<MOD2>:[TID]:<facility>:[CTAG];

where:

facility is the AID facility

Example

Input

RST-EC1:CISCO:FAC-1-1:1234;

Errors

This message generates all the default errors


11.11.61 RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)

This command retrieves the parameters of an OC-N facility.

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::::;

where:

fac_aid is the AID facility and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<fac_aid>:[SDCC=<sdcc>],[TMERGF=<tmgref>],[SPNWTR=<spnwtr>],
[PJMON=<pjmon>],[SFBER=<sfber>],[SDBER=<sdber>],
[MODE=<mode>],[WVLEN=<wvlen>]:<pst>,,<role>,<status>"
;

where:

fac_aid is the AID facility

sdcc is of type SDCC_MODE and is optional

tmgref is of type TMG_REF and is optional

spnwtr is of type REVERTIVE_TIME and is optional

pjmon is an Integer and is optional

sfber is of type SF_BER and is optional

sdber is of type SD_BER and is optional

mode is of type OPTICAL-MODE. mode is optional

wvlen is the optical signal wavelength in nanometers; it is a Float and is optional

pst is of type PST

role is of type SIDE

status is of type STATUS

Example

Input

RTRV-OC3:CISCO:FAC-15-2:123::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-15-2:SDCC=N, TMGREF=N, SPNWTR=8.5, PJMON=0,
SFBER=1E-4, SDBER=1E-7, MODE=SONET, WVLEN=1310.00:OOS,,
WORK,STBY"
;

Errors

This message generates all the default errors


11.11.62 RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)

This command retrieves the attributes associated with an STS path.

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-<STS_PATH>:[TID]:<sts_aid>:[CTAG]::::;

where:

sts_aid is the AID sts and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<sts_aid>:RATE=<stsrate>,[SFBER=<sfber>],[SDBER=<sdber>]"
;

where:

sts_aid is the AID sts

stsrate is the STS Rate and is of type STS_PATH

sfber is of type SF_BER and is optional

sdber is of type SD_BER and is optional

Example

Input

RTRV-STS1:FERNDALE:STS-2-4:238::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"STS-2-4:RATE=STS1,SFBER=1E-3,SDBER=1E-5"
;

Errors

This message generates all the default errors


11.11.63 RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)

Instructs the network to retrieve and send the current status of its alarm conditions. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM BITS RTRV-ALM-ENV

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-ALL RTRV-COND-SYNCN

Input Format

RTRV-ALM-<MOD2ALM>:[TID]:<aid>:[CTAG]::[<ntfcncde>],[<condition>],
[<serv_eff>],,,;

where:

aid is the AID facility and must not be null

ntfcnde is the 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"

condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"

serveff of type SERV_EFF and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<aid>,<type>:<ntfcnde>,<condition>,<srveff>,,,,:<desc>"
;

where:

aid is the AID facility

type specifies the type of OC-N facility associated with the facility AID; type is of type MOD2ALM

ntfcnde is the 2-letter notification code and is of type NOTIF_CODE

condition is a type of alarm condition and is of type CONDITION

srveff is the type of effect on service caused by the alarm condition and is of type SERV_EFF

desc is a String

Example

Input

RTRV-ALM-OC12:ELDRIDGE:FAC-6-1:255::MN,SD,SA,,,;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-6-1,OC12:MJ,SD,SA,,,,:\"BER AT SIGNAL DEGRADE LEVEL\","
;

Errors

This message generates all the default errors


11.11.64 RTRV-ALM-ALL: Retrieve Alarm All

This command instructs the NE to retrieve and send the current status of all active alarm conditions. The alarm condition or severity retrieved is specified using the input parameters as a filter.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM BITS RTRV-ALM-ENV

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-ALM-ALL:[TID]::[CTAG]::,,,,,;

Output Format

SID DATE TIME
M CTAG COMPLD
"<aid>,<aid_type>:<notifCode>,<condition1>,<servEff>,,,,,:<dnField>"
;

where:

aid is the aid where the alarm took place and d is the AID ALL

aid_type is of type MOD2

notifCode is of type NOTIF_CODE

condition1 is of type CONDITION

servEff is a service-affecting alarm and is of type SERV_EFF

dsField is a String

Example

Input

RTRV-ALM-ALL:COTATI::229::,,,,,;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-2,EQPT:MN,PWRRESTART,NSA,,,,,:\"POWERFAIL
RESTART\","
;

Errors

This message generates all the default errors


11.11.65 RTRV-ALM-BITS: Retrieve Alarm Building Integrated Timing Supply

This command instructs the NE to retrieve and send the current status of its alarm conditions associated with the BITS facility. The alarm condition or severity retrieved is specified using the input parameters as a filter.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-ALL

REPT ALM BITS RTRV-ALM-ENV

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-ALM-BITS:[TID]:<bits_aid>:[CTAG]::[<ntfcncde>],[<condition>],
[<serv_eff>];

where:

bits_aid is the AID bits and must not be null.

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"

condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"

serv_eff is a type of effect on service caused by the alarm condition and is of type SERV_EFF; a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<bits_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>"
;

where:

bits_aid is the AID bits

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE

condition is a type of alarm condition and is of type CONDITION

srveff is a type of effect on service caused by the alarm condition and is of type SERV_EFF

desc is a String

Example

Input

RTRV-ALM-BITS:ELVERANO:BITS-1:288::CR,LOS,SA;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"BITS-1:CR,LOS,SA,,,,:\"LOSS OF SIGNAL\","
;

Errors

This message generates all the default errors


11.11.66 RTRV-ALM-ENV: Retrieve Alarm Environment

This command instructs the NE to retrieve outstanding environmental alarms.

Section
Description 

Category

Environment

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-ALL

REPT ALM BITS RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-ALM-ENV:[TID]:[<env>]:[CTAG]::[<notifCode>],[<envAlm>];

where:

env is the AID env and is listable; a null value is equivalent to "ALL"

notifCode is of type NOTIF_CODE and a null value is equivalent to "ALL"

envAlm is of type ENV_ALM and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<env>:<notifCode>,<envAlm>,,,[<desc>]"
;

where:

env is the AID env

notifCode is of type NOTIF_CODE

envAlm is of type ENV_ALM

desc is a String

Example

Input

RTRV-ALM-ENV:CISCO-1:ENV-IN-1:123::MJ,OPENDR;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"ENV-IN-1:MJ,OPENDR,,,\"OPEN DOOR\""
;

Errors

This message generates all the default errors


11.11.67 RTRV-ALM-EQPT: Retrieve Alarm Equipment

This command instructs the NE to retrieve and send the current status of its equipment-unit alarm conditions. The alarm condition or severity retrieved is specified using the input parameters as a filter.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-<MOD2ALM>

ED-FFP-EQPT RTRV-ALM-ALL

ENT-EQPT RTRV-ALM-BITS

ENT-FFP-EQPT RTRV-ALM-ENV

OPR-PROTNSW-EQPT RTRV-ALM-SYNCN

REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT ALM BITS RTRV-COND-ALL

REPT ALM ENV RTRV-COND-BITS

REPT ALM EQPT RTRV-COND-EQPT

REPT ALM SYNCN RTRV-COND-SYNCN

REPT EVT <MOD2ALM> RTRV-EQPT

REPT EVT EQPT RTRV-FFP-EQPT

REPT EVT SYNCN SW-DX-EQPT

Input Format

RTRV-ALM-EQPT:[TID]:<eqpt_aid>:[CTAG]::[<ntfcncde>],[<condition>],
[<serv_eff>],,,;

where:

eqpt_aid is the AID eqpt and must not be null

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"

condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"

serv_eff is of type SERV_EFF and is null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<eqpt>,<eqpt_type>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>"
;

where:

eqpt is the AID eqpt

eqpt_type specifies the type of card associated with the slot AID for equipment units; eqpt_type is of type EQPT_TYPE

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE

condition is a type of alarm condition and is of type CONDITION

srveff is a type of effect on service caused by the alarm condition; srveff is of type SERV_EFF

desc is a String

Example

Input

RTRV-ALM-EQPT:TWOROCK:SLOT-7:227::MJ,HITEMP,NSA,,,;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-7,TCC:MJ,HITEMP,NSA,,,,:\"HIGH TEMPERATURE\","
;

Errors

This message generates all the default errors


11.11.68 RTRV-ALM-SYNCN: Retrieve Alarm Synchronization

Instructs the NE to retrieve and send the current status of its alarm conditions associated with a synchronization facility. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.

Section
Description 

Category

Synchronization

Security

Read Only

Related Messages

ED-SYNCN RTRV-ALM-ALL

OPR-SYNCNSW RTRV-ALM-BITS

REPT ALM <MOD2ALM> RTRV-ALM-ENV

REPT ALM BITS RTRV-ALM-EQPT

REPT ALM ENV RTRV-COND-<MOD2ALM>

REPT ALM EQPT RTRV-COND-ALL

REPT ALM SYNCN RTRV-COND-BITS

REPT EVT <MOD2ALM> RTRV-COND-EQPT

REPT EVT EQPT RTRV-COND-SYNCN

REPT EVT SYNCN RTRV-SYNCN

RTRV-ALM-<MOD2ALM>

Input Format

RTRV-ALM-SYNCN:[TID]:[<sync_aid>]:[CTAG]::[<ntfcncde>],[<condition>],
[<serv_eff>];

where:

sync_aid is the AID sync_ref and is listable; a null value is equivalent to "ALL"

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"

condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"

serv_eff is a type of effect on service caused by the alarm condition; serv_eff is of type SERV_EFF and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<sync_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>"
;

where:

sync_aid identifies the facility queried and is the AID sync_ref

ntfcncde is a 2-letter notification code and is of type NOTIF_CODE

condition is a type of alarm condition and is of type CONDITION

srveff is a type of effect on service caused by the alarm condition; serveff is of type SERV_EFF

desc is a String

Example

Input

RTRV-ALM-SYNCN:FULTON:SYNC-NE:226::CR,FAILTOSW,SA;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SYNC-NE:CR,FAILTOSW,SA,,,,:\"FAILURE TO SWITCH TO
PROTECTION\","
;

Errors

This message generates all the default errors


11.11.69 RTRV-BITS: Retrieve Building Integrated Timing Supply

This command retrieves the BITS configuration command.

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-BITS:[TID]:<bits_aid>:[CTAG]::::;

where:

bits_aid is the AID bits and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<bits_aid>:LNCDE=<line_code>,FMT=<frame_format>:<pst>"
;

where:

bits_aid is the AID bits

line_code is of type LINE_CODE

frame_format is of type FRAME_FORMAT

pst is of type PST

Example

Input

RTRV-BITS:SONOMA:BITS-1:782::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"BITS-1:LNCDE=AMI,FMT=ESF:IS"
;

Errors

This message generates all the default errors


11.11.70 RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command instructs the NE to retrieve the current standing condition and/or state associated with an entity.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-ALL

REPT ALM BITS RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-ENV

REPT ALM EQPT RTRV-ALM-EQPT

REPT ALM SYNCN RTRV-ALM-SYNCN

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-COND-<MOD2ALM>:[TID]:[<facility>]:[CTAG]::[<condition>],,,;

where:

facility is the facility aid and is the AID facility; a null value is equivalent to "ALL"

condition is the requested condition, if not set=> we want all the conditions for the specified facility; condition is of type CONDITION and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>,<eqptType>:[<notifcode>],<condition>,[<servEff>],,,,,,
[<desc>]"
;

where:

facility is the facility aid and is the AID facility

eqptType is of type EQPT_TYPE

notifCode is the notification code; notifCode is of type NOTIF_CODE and is optional

condition is the condition itself and is of type CONDITION

servEff is of type SERV_EFF and is optional

desc is the condition description; desc is a String and is optional

Example

Input

RTRV-COND-T3:TID:FAC-2-1:229::LOS,,,;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-2-1,DS3-12:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\""
;

Errors

This message generates all the default errors


11.11.71 RTRV-COND-ALL: Retrieve Condition All

This command instructs the NE to retrieve the current standing condition for all entities.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-ALL

REPT ALM BITS RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-ENV

REPT ALM EQPT RTRV-ALM-EQPT

REPT ALM SYNCN RTRV-ALM-SYNCN

REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-COND-ALL:[TID]::[CTAG]::[<condition>],::;

where:

condition is of type CONDITION and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>,[<aid_type>]:[<notifCode>],<condition>,[<servEff>],,,,,,
[<desc>]"
;

where:

facility is the AID facility

aid_type is of type MOD2B and is optional

notifCode is of type NOTIF_CODE and is optional

condition is of type CONDITION

servEff is of type SERV_EFF and is optional

desc is a String and is optional

Example

Input

RTRV-COND-ALL::TID::229::LOS,,,:

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-2-1,OC3:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\""
;

Errors

This message generates all the default errors


11.11.72 RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply

This command instructs the NE to retrieve the standing conditions on BITS.

Section
Description 

Category

Fault

Security

Read Only

Related Messages

REPT ALM <MOD2ALM> RTRV-ALM-ALL

REPT ALM BITS RTRV-ALM-BITS

REPT ALM ENV RTRV-ALM-ENV

REPT ALM EQPT RTRV-ALM-EQPT

REPT ALM SYNCN RTRV-ALM-SYNCN

REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>

REPT EVT EQPT RTRV-COND-ALL

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN

Input Format

RTRV-COND-BITS:[TID]:<facility>:[CTAG]::[<condition>],,,;

where:

facility is the AID bits and must not be null

condition is of type CONDITION and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>,<eqptType>:[<notifCode>],<condition>,[<servEff>],,,,,,
[<desc>]"
;

where:

facility is the AID bits

eqptType is of type EQPT_TYPE

notifCode is of type NOTIF_CODE and is optional

condition is of type CONDITION

servEff is of type SERV_EFF and is optional

desc is a String and is optional

Example

Input

RTRV-COND-BITS:TID:BITS-1:229::LOS,,,:

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"BITS-1,TCC:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\""
;

Errors

This message generates all the default errors


11.11.73 RTRV-COND-EQPT: Retrieve Condition Equipment

This command instructs the NE to retrieve current equipment conditions.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT RLS-PROTNSW-EQPT

DLT-FFP-EQPT RTRV-ALM-<MOD2ALM>

ED-FFP-EQPT RTRV-ALM-ALL

ENT-EQPT RTRV-ALM-BITS

ENT-FFP-EQPT RTRV-ALM-ENV

OPR-PROTNSW-EQPT RTRV-ALM-EQPT

REPT ALM <MOD2ALM> RTRV-ALM-SYNCN

REPT ALM BITS RTRV-COND-<MOD2ALM>

REPT ALM ENV RTRV-COND-ALL

REPT ALM EQPT RTRV-COND-BITS

REPT ALM SYNCN RTRV-COND-SYNCN

REPT EVT <MOD2ALM> RTRV-EQPT

REPT EVT EQPT RTRV-FFP-EQPT

REPT EVT SYNCN SW-DX-EQPT

Input Format

RTRV-COND-EQPT:[TID]:<facility>:[CTAG]::[<condition>],,,;

where:

facility is the AID and must not be null.

condition is of type CONDITION and a null value is equivalent to "ALL"

Output Format

SID DATE TIME

M CTAG COMPLD

"<facility>,<eqptType>:[<notifCode>],<condition>,[<servEff>],,,,,,[<desc>]"

;

where:

facility is the AID facility

eqptType is of type EQPT_TYPE

notifCode is of type NOTIF_CODE and is optional

condition is of type CONDITION

servEff is of type SERV_EFF and is optional

desc is a String and is optional

Example

Input

RTRV-COND-EQPT:TID:SLOT-1:229::LOS,,,:

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-1,DS3-12:CR,LOS,SA,,,,,,,\"LOS OF SIGNAL\""
;

Errors

This message generates all the default errors


11.11.74 RTRV-COND-SYNCN: Retrieve Condition Synchronization

This command retrieves the synchronization condition.

Section
Description 

Category

Synchronization

Security

Read Only

Related Messages

ED-SYNCN RTRV-ALM-ALL

REPT ALM <MOD2ALM> RTRV-ALM-BITS

REPT ALM BITS RTRV-ALM-ENV

REPT ALM ENV RTRV-ALM-EQPT

REPT ALM EQPT RTRV-ALM-SYNCN

REPT ALM SYNCN RTRV-COND-<MOD2ALM>

REPT EVT <MOD2ALM> RTRV-COND-ALL

REPT EVT EQPT RTRV-COND-BITS

REPT EVT SYNCN RTRV-COND-EQPT

RTRV-ALM-<MOD2> RTRV-SYNCN

Input Format

RTRV-COND-SYNCN:[TID]:<facility>:[CTAG]::[<condition>],,,;

where:

facility is the AID sync_ref and must not be null

condition is of type CONDITION and a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>,[<eqptType>]:[<notifCode>],<condition>,[<servEff>],,,,,,
[<desc>]"
;

where:

facility is the AID sync_ref

eqptType is of type EQPT_TYPE and is optional

notifCode is of type NOTIF_CODE and is optional

condition is of type CONDITION

servEff is of type SERV_EFF and is optional

desc is a String and is optional

Example

Input

RTRV-COND-SYNCN:TID:SYNC-NE:229::LOS,,,:

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SYNC-NE,TCC:MJ,FRNGSYNC,SA,,,,,,\"FREE RUNNING
SYNCHRONIZAION MODE\""
;

Errors

This message generates all the default errors


11.11.75 RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)

This command retrieves any connections associated with the Access Identifiers entered. FROM and TO information is returned along with the type of connection.

Section
Description 

Category

Cross Connect

Security

Read Only

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-VT1

Input Format

RTRV-CRS-<STS_PATH>:[TID]:<sts_ep>:[CTAG]::,,,;

where:

sts_ep is the AID sts and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<crs_ep>,<crs_ep1>:<cct>"
;

where:

crs_ep is the AID sts

crs_ep1 is the AID sts

cct is the cross connect type and is of type CCT

Example

Input

RTRV-CRS-STS3C:KENWOOD:STS-6-1:223::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"STS-6-1,STS-12-4:2WAY"
;

Errors

This message generates all the default errors


11.11.76 RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary

This command retrieves the VT cross-connection information.

Section
Description 

Category

Cross Connect

Security

Read Only

Related Messages

DLT-CRS-<STS_PATH>

DLT-CRS-VT1

ED-CRS-<STS_PATH>

ED-CRS-VT1

ENT-CRS-<STS_PATH>

ENT-CRS-VT1

RTRV-CRS-<STS_PATH>

Input Format

RTRV-CRS-VT1:[TID]:<vt>:[CTAG]::::;

where:

vt is the AID vt1_5 and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<from>,<to>:<cct>"
;

where:

from is the first (FROM) VT in cross-connection and is the AID vt1_5

to is the second (TO) VT in cross-connection and is the AID vt1_5

cct is the cross connect type and is of type CCT

Example

Input

RTRV-CRS-VT1:CISCO:VT1-2-3-1:1234::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"VT1-2-3-1,VT1-4-4-1:1WAY"
;

Errors

This message generates all the default errors


11.11.77 RTRV-EC1: Retrieve Electrical Carrier Level 1

This command retrieves the facility status of an EC-1 card.

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-EC1:[TID]:<fac>:[CTAG]::::;

where:

fac is the facility aid and is the AID facility; fac must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<fac>:PJMON=<pjmon>,LBO=<lbo>:PST=<pst>"
;

where:

fac is the facility aid and is the AID facility

pjmon is the SONET pointer monitor and is an Integer

lbo is line buildout and is of type E_LBO

pst is the primary service state and is of type PST

Example

Input

RTRV-EC1:CISCO:FAC-1-1:1234::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-1-1:PJMON=0,LBO=0-225:PST=IS"
;

Errors

This message generates all the default errors


11.11.78 RTRV-EQPT: Retrieve Equipment

This command retrieves the data and state parameters associated with an equipment unit.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT REPT EVT EQPT

DLT-FFP-EQPT RLS-PROTNSW-EQPT

ED-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-FFP-EQPT

OPR-PROTNSW-EQPT SW-DX-EQPT

REPT ALM EQPT

Input Format

RTRV-EQPT:[TID]:<eqpt_aid>:[CTAG]::::;

where:

eqpt_aid is the AID eqpt and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<eqpt_aid>:[<eqpt_type>]:[WTR=<wtr>],[NAME=<name>]:<state>,
<equip>,[<role>],[<status>]"
;

where:

eqpt_aid is the AID eqpt

eqpt_type is the type of card in the slot; eqpt_type is of type EQPT_TYPE and is optional

wtr is an Integer and is optional

name is a String and is optional

state is of type PST

equip indicates if the equipment unit is physically present and is of type EQUIP.

role indicates if the card is a working unit or the protecting unit; role is of type SIDE and is optional

status is of type STATUS and is optional

Example

Input

RTRV-EQPT:MIRABEL:SLOT-12:230::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-12:OC12:WTR=99,NAME=DESCRIPTION:IS,EQUIP,,ACT"
;

Errors

This message generates all the default errors


11.11.79 RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)

This command retrieves the optical facility protection information.

Section
Description 

Category

Facility Protection

Security

Read Only

Related Messages

N/A

Input Format

RTRV-FFP-<OCN_TYPE>:[TID]:<facility>:[CTAG];

where:

facility is the AID facility and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<work>,<protect>:NAME=<name>,RVTT=<revertiveType>,
RVTM=<revertiveTime>,BSWM=<bswMode>"
;

where:

work is the AID facility

protect is the AID facility

name is the protection name and is a String

revertiveType is the revertive type and e is of type REVERTIVE_TYPE

revertiveTime is the revertive time and is of type REVERTIVE_TIME

bswMode specifies if it is a bidirectional switch mode and is of type ON_OFF

Example

Input

RTRV-FFP-OC3:PETALUMA:FAC-3-1:1;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-3-1,FAC-4-1:NAME=PROT_NAME,RVTT=R,RVTM=1.0,
BSWM=OFF"
;

Errors

This message generates all the default errors


11.11.80 RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment

This command retrieves the equipment protection information.

Section
Description 

Category

Equipment

Security

Read Only

Related Messages

DLT-EQPT REPT EVT EQPT

DLT-FFP-EQPT RLS-PROTNSW-EQPT

ED-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT SW-DX-EQPT

REPT ALM EQPT

Input Format

RTRV-FFP-EQPT:[TID]:<eqpt>:[CTAG];

where:

eqpt is the AID eqpt and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<work>,<protect>:PRT=<protectionGroup>,NAME=<name>,
RVTT=<revertiveType>,RVTM=<revertiveTime>,BSWM=<bswMode>"
;

where:

work is the working slot aid and is the AID eqpt

protect is the protection slot aid and is the AID eqpt

protectionGroup is the protection group and is of type PROTECTION_GROUP

name is the protection name and is a String

revertiveType is of type REVERTIVE_TYPE

revertiveTime is of type REVERTIVE_TIME

Example

Input

RTRV-FFP-EQPT:PETALUMA:SLOT-16:1;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-16,SLOT-17:PRT=1-1,NAME=PROT_NAME,RVTT=R,RVTM=1.0"
;

Errors

This message generates all the default errors


11.11.81 RTRV-HDR: Retrieve Header

This command instructs the NE to return the header of a TL1 response message. Used by TL1 clients to determine if the link to the NE is still active and if the NE is responding to commands.

Section
Description 

Category

System

Security

Read Only

Related Messages

ACT-USER

ALW-MSG-ALL

CANC-USER

ED-DAT

INH-MSG-ALL

INIT-SYS

Input Format

RTRV-HDR:[TID]::[CTAG];

Example

Input

RTRV-HDR:SONOMA::232;

Errors

This message generates all the default errors


11.11.82 RTRV-INV: Retrieve Inventory

This command queries the NE and returns a listing of the equipment inventory. For each unit in the system, it identifies the unit's hardware version and revision numbers, firmware version, and the unit's CLEI code.

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-INV:[TID]:<eqpt_aid>:[CTAG]::,,;

where:

eqpt_aid is the AID eqpt and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<eqpt_aid>,<eqptType>:[PN=<pn>],[HWVER=<hwver>],
[FWVER=<fwver>],[SN=<sn>],[CLEI=<clei>]"
;

where:

eqpt_aid is the AID eqpt

eqpt_type is of type EQPT_TYPE

pn is a String and is optional

hwver is a String and is optional

fwver is a String and is optional

sn is an integer and is optional

clei is a String and is optional

Example

Input

RTRV-INV:OCCIDENTAL:SLOT-15:301::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SLOT-15,OC3-IR-4:PN=87-00002,HWVER=004K,
FWVER=76-99-00009-004A,SN=013510,CLEI=NOCLEI"
;

Errors

This message generates all the default errors


11.11.83 RTRV-LOG: Retrieve Log

This command retrieves the alarm log of the NE.

Section
Description 

Category

Log

Security

Read Only

Related Messages

N/A

Input Format

RTRV-LOG:[TID]::[CTAG];

Output Format

SID DATE TIME
M CTAG COMPLD
"<aid>,<seq>:CURRENT=<current>,[PREVIOUS=<previous>],
<condition>,servEff>,[TIME=<time>],DATE=<date>:<desc>"
;

where:

aid is the AID ALL

seq is an Integer

current is of type NOTIF_CODE

previous is of type COND_EFF and is optional

condition is of type CONDITION

servEff is of type SERV_EFF

time is a Date and is optional

date is a String

desc is a String

Example

Input

RTRV-LOG:CISCO::123;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-3-1,12:CURRENT=MJ,PREVIOUS=CL,EOC,NSA,TIME=16-33-04,
DATE=1971-02-03:\"SDCC TERMINATION FAILURE\""
;

Errors

This message generates all the default errors


11.11.84 RTRV-NE: Retrieve Network Element

This command retrieves the attributes of the NE system such as the node identity (e.g. IP address), external interfaces (e.g. LAN ports), and major modes of operation (e.g. SONET vs. SDH).

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-NE:[TID]::[CTAG]::::;

Output Format

SID DATE TIME
M CTAG COMPLD
"IPADDR=<ipaddr>,IPMASK=<ipmask>,DEFRTR=<defrtr>,
EXTLAN=<extlan>,INTLAN=<intlan>,RTRMDE=<rtrmode>,
STM=<stm>,NODEID=<nodeid>,EXTRNG=<ext_ring>,
RNGWTR=<rngwtr>,TMMD=<timing_mode>,SSMG=<sync_gen>,
NSQL=<sync_quality_level>"
;

where:

ipaddr is the IP address of the NE on the local LAN and is a String

ipmask is the IP Mask used to identify the sub-net on which the NE resides; ipmask is a String

defrtr is the IP address of the default router and is a String

extlan is of type EXT_LAN

intlan is of type EXT_LAN

rtrmode is of type EXT_LAN

stm is of type OPTICAL_MODE

nodeid is the Node ID of the NE in the BLSR and is an Integer

ext_ring is the node/ring that supports the extended K1/K2/K3 protocol for more than 16 nodes per BLSR; ext_ring is of type EXT_RING

rngwtr is an Integer

timing_mode is of type TIMING_MODE

sync_gen is of type SYNC_GENERATION

sync_quality_level is of type SYNC_QUALITY_LEVEL

Example

Input

RTRV-NE:LAKEVILLE::233::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"IPADDR=192.168.100.52,IPMASK=255.255.255.0,
DEFRTR=192.168.100.1,EXTLAN=OFF,INTLAN=OFF,
RTRMDE=OFF,STM=SONET,NODEID=3,EXTRNG=N,RNGWTR=99,
TMMD=LINE,SSMG=GEN1,NSQL=ABOVE-PRS"

;

Errors

This message generates all the default errors


11.11.85 RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command retrieves the performance monitoring for specified card type.


Note   Release 2.2.1 does not support the 48C value.


Section
Description 

Category

Performance

Security

Read Only

Related Messages

INIT-REG-<MOD2>

RTRV-TH-<MOD2>

SET-TH-<MOD2>

Input Format

RTRV-PM-<MOD2>:[TID]:<aid>:[CTAG]::,,,,<tmpr>,,;

where:

aid is the AID ALL and must not be null

tmpr is of type TMPR and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<aid>:<montype>,<monval>,<validity>,<location>,<tmpr>,<direction>"
;

where:

aid is the AID ALL

montype is the monitored type ex CVL, ESL and is of type ALL_MONTYPE

monval is the monitored value and l is an Integer

validity is of type VALIDITY

location is the location far-end, near-end or both; location is of type LOCATION

tmpr is the time period 15 min, 1 hour or 1 day; tmpr is of type TMPR

direction is the direction receive, transmit or both; direction is of type DIRECTION

Example

Input

RTRV-PM-T1:TID:AID:123::,,,,15MIN,,;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"AID:CVL,21,COMPL,FEND,15MIN,RCV,,"
;

Errors

This message generates all the default errors


11.11.86 RTRV-SYNCN: Retrieve SYNCN

This command retrieves the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources may be specified (e.g. PRIMARY, SECOND,THIRD).

Section
Description 

Category

Synchronization

Security

Read Only

Related Messages

ED-SYNCN

OPR-SYNCNCSW

REPT ALM SYNCN

REPT EVT SYNCN

RTRV-ALM-SYNCN

RTRV-COND-SYNCN

Input Format

RTRV-SYNCN:[TID]:<sync_aid>:[CTAG]::::;

where:

sync_aid identifies the synchronization reference to retrieve and is the AID sync_ref; sync_ref is listable and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<sync_aid>:PRIMARY=<primary>,SECOND=<second>,THIRD=<third>"
;

where:

sync_aid is the synchronization reference to be modified and is the AID sync_ref

primary is the AID syn_src

second is the AID syn_src

third is the AID syn_src

Example

Input

RTRV-SYNCN:BOYES:SYNC-NE:234::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"SYNC-NE:PRIMARY=FAC-1-2,SECOND=FAC-2-2,THIRD=FAC-3-2;"
;

Errors

This message generates all the default errors


11.11.87 RTRV-T1: Retrieve T1

This command retrieves the DS-1 facilities configuration.

Section
Description 

Category

Other

Security

Read Only

Related Messages

ED-T1

ED-T3

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-T1

RLS-LPBK-T3

RTRV-T3

Input Format

RTRV-T1:[TID]:<aid>:[CTAG]::::;

where:

aid is the AID facility and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<aid>:STATE=<pst>,ID=<id>,LNCDE=<line_code>,
FRMF=<fame_format>,LBO=<line_buildout>"
;

where:

aid is the AID facility

pst is of type PST

id is a String

line_code is of type LINE_CODE

frame_format is of type FRAME_FORMAT

line_buildout is of type LINE_BUILDOUT

Example

Input

RTRV-T1:TID:AID:1223::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"AID:STATE=OOS,ID=CISCO,LNCDE=AMI,FRMF=ESF,LBO=0-131"
;

Errors

This message generates all the default errors


11.11.88 RTRV-T3: Retrieve T3

This command retrieves the facilities properties of a DS-3 and a DS-3 transmux card.

Section
Description 

Category

Other

Security

Read Only

Related Messages

ED-T1

ED-T3

OPR-LPBK-T1

OPR-LPBK-T3

RLS-LPBK-T1

RLS-LPBK-T3

RTRV-T1

Input Format

RTRV-T3:[TID]:<facility>:[CTAG]::::;

where:

facility is the facility aid FAC-[SLOT]-[1..6] or FAC-[SLOT]-[1..12]; facility is the AID facility and must not be null

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>:LNTYPE=<lineType>,[LNCODE=<lineCode>],LBO=<lbo>:
PST=<pst>"
;

where:

facility is the facility aid FAC-[SLOT]-[1..6] or FAC-[SLOT]-[1..12] and is the AID facility.

lineType is the port line type and is of type DS_LINE_TYPE

lineCode is the port one code; lineCode is of type DS_LINE_CODE and is optional

lbo is the circuit line buildout and is of type E_LBO

pst is of type PST

Example

Input

RTRV-T3:CISCO:FAC-1-2:123::::;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-1-2:LNTYPE=C-BIT,LNCODE=B3ZS,LBO=0-225:PST=IS"
;

Errors

This message generates all the default errors


11.11.89 RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command retrieves the threshold level.


Note   Release 2.2.1 does not support STS48C and VT1.


Section
Description 

Category

Performance

Security

Read Only

Related Messages

INIT-REG-<MOD2>

RTRV-PM-<MOD2>

SET-TH-<MOD2>

Input Format

RTRV-TH-<MOD2>:[TID]:<facility>:[CTAG]::<allMontype>,[<location>],
[<tmpr>];

where:

facility is the aid type and is the AID ALL; facility must not be null

allMontype is the monitored type and is of type ALL_MONTYPE; allMontype must not be null

location is the location and is of type LOCATION; a null value is equivalent to "ALL"

tmpr is the time period and is of type TMPR; a null value is equivalent to "ALL"

Output Format

SID DATE TIME
M CTAG COMPLD
"<facility>,[<eqptType>]:<allMontype>,[<location>],,<thval>,[<tmpr>]"
;

where:

facility is the aid and is the AID ALL

eqptType is of type EQPT_TYPE and is optional

allMontype is the monitored type and is of type ALL_MONTYPE

location is the location and is of type location; location is optional

thVal is the threshold value and is an Integer

tmpr is the time period and is of type TMPR; tmpr is optional

Example

Input

RTRV-TH-T3:CISCO:FAC-1-3:1234::CVL,FEND,15MIN;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"FAC-1-3,DS3-12:CVL,FEND,,1,15MIN"
;

Errors

This message generates all the default errors


11.11.90 RTRV-TOD: Retrieve Time of Day

This command queries the NE and displays the system date and time at the instant when the command was executed. The time returned is in Coordinated Universal Time (UTC).

Section
Description 

Category

Other

Security

Read Only

Related Messages

N/A

Input Format

RTRV-TOD:[TID]::[CTAG];

Output Format

SID DATE TIME
M CTAG COMPLD
"<year>,<month>,<day>,<hour>,<minute>,<second>,,<tmtype>"
;

where:

year is an Integer

month is an Integer

day is an Integer

hour is an Integer

minute is an Integer

second is an Integer

tmtype is a String

Example

Input

RTRV-TOD:CAZADERO::230;

Output

TID-000 98-06-20 14-30-00
M 001 COMPLD
"1998,05,08,17,01,33,,UTC"
;

Errors

This message generates all the default errors


11.11.91 SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)

This command sets the threshold level.


Note   Release 2.2.1 does not support STS48C.


Section
Description 

Category

Performance

Security

Read/Write

Related Messages

INIT-REG-<MOD2>

RTRV-TH-<MOD2>

RTRV-PM-<MOD2>

Input Format

SET-TH-<MOD2>:[TID]:<facility>:[CTAG]::<allMontype>,<thVal>,
[<location>],,[<tmpr>];

where:

facility is the aid and is the AID ALL

allMontype is the monitored value and is of type ALL_MONTYPE

thVal is the threshold value and is an Integer

location is the location and is of type LOCATION

tmpr is the time period and is of type TMPR

Example

Input

SET-TH-T3:CISCO:FAC-1-1:123::CVL,12,NEND,,15MIN;

Errors

This message generates all the default errors


11.11.92 SET-TOD: Set Time of Day

This command sets the system date and time for the NE. The year should be entered using four digits while the hour should be entered using a 24-hour time period (i.e. military time).

Section
Description 

Category

Other

Security

Read/Write

Related Messages

N/A

Input Format

SET-TOD:[TID]::[CTAG]::<year>,<month>,<day>,<hour>,<minute>,<second>,[<difference>]:[USEDST=<usedst>];

where:

year is the current calendar year and is an Integer

month is the month of the year and ranges from 01 to 12; month is an Integer

day is the day of the month and ranges from 01 to 31; day is an Integer

hour is the hour of the day and ranges from 00 to 59; hour is an Integer

minute is the minute of the hour and ranges from 00 to 59; minute is an Integer

second is the second of the minute and ranges from 00 to 59; second is an Integer

difference is the number of minutes behind UTC and is an Integer

usedst indicates if Daylight Saving Time is used and is of type USE_DST

Example

Input

SET-TOD:CAZADERO::240::1998,05,08,13,18,55,480:USEDST=Y;

Errors

This message generates all the default errors


11.11.93 SW-DX-EQPT: Switch DX Equipment

This command instructs the NE to switch duplex equipment.

Section
Description 

Category

Equipment

Security

N/A

Related Messages

DLT-EQPT REPT EVT EQPT

DLT-FFP-EQPT RLS-PROTNSW-EQPT

ED-FFP-EQPT RTRV-ALM-EQPT

ENT-EQPT RTRV-COND-EQPT

ENT-FFP-EQPT RTRV-EQPT

OPR-PROTNSW-EQPT RTRV-FFP-EQPT

REPT ALM EQPT

Input Format

SW-DX-EQPT:[TID]:<eqpt>:[CTAG]::[<dxModeOp>],;

where:

eqpt is the AID eqpt

dxModeOp is of type DX_MODE_OP

Example

Input

SW-DX-EQPT:CISCO:SLOT-1:123::FRCD,;

Errors

This message generates all the default errors


11.12 Access Identifiers

The Access Identification code (AID) directs an input command to its intended physical or data entity inside the NE. Equipment Modules and facilities are typical examples of entities addressed by the access code.

Table 11-13 Access Identifiers

AID
Patterns

bits

BITS-ALL

BITS-{1,2}

ds-1

DS1-{1-6,12-17}-{1-6}-{1-28}

env

ENV-IN-{1-4}

eqpt

SLOT-{1-17}

SLOT-{1-6,12-17}

facility

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-{1-12}

FAC-{1-6,12-17}-{1-14}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{5,6,12,13}-1

sts

STS-{1-6,12-17}-1

STS-{1-6,12-17}-{1,4,7,10-46}

STS-{1-6,12-17}-{1-12}

STS-{1-6,12-17}-{1-6}

STS-{5,6,12,13}-{1,13,25,37}

STS-{5,6,12,13}-{1,4,7,10-46}

STS-{5,6,12,13}-{1-48}

STS-{5,6,12,13}-{1}

syn_src

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-{1-4}

FAC-{5,6,12,13}-1

INTERNAL

SYNC-NE

SYNC-{BITS1,BITS2}

sync_ref

SYNC-NE

SYNC-{BITS1,BITS2}

vt1_5

VT1-{1-6,12-17}-1-{1-14}

VT1-{1-6,12-17}-{1-12}-{1-28}

VT1-{1-6,12-17}-{1-6}-{1-28}

VT1-{5,6,12,13}-{1-48}-{1-28}


11.12.1 bits

Table 11-14 bits

Pattern
Description
BITS-ALL
BITS-1 and BITS-2
BITS-{1,2}
Individual BITS AID

11.12.2 ds-1

Used to access the DS-1 frame layer of the DS3XM-6

Table 11-15 ds-1

Pattern
Description

DS1-{1-6,12-17}-{1-6}-{1-28}

DS-1 aid for a DX3Xm card


11.12.3 env

The AIC card environmental AIDs

Table 11-16 env

Pattern
Description

ENV-{IN}-{1-4}

Environmental alarm aid


11.12.4 eqpt

Table 11-17 eqpt

Pattern
Description

SLOT-{1-17}

Equipment aid for the whole NE

SLOT-{1-6,12-17}

Equipment aid for the I/O slots


11.12.5 facility

Used to access specific ports

Table 11-18 facility 

Pattern
Description

FAC-{1-6,12-17}-1

Facility aid for the OC-12

FAC-{1-6,12-17}-{1-12}

Facility aid for the EC-1 and DS-3 cards

FAC-{1-6,12-17}-{1-14}

Facilities for the DS-1 card

FAC-{1-6,12-17}-{1-4}

Facility aid for the OC-3 card

FAC-{1-6,12-17}-{1-6}

Facility aid for the DS3XM card

FAC-{5,6,12,13}-1

Facility aid for the OC-48 card


.

11.12.6 sts

SONET frame-level AID set

Table 11-19 sts

AID
Description

STS-{1-6,12-17}-1

STS-1 aid for DS-1 cards

STS-3C aid for OC-3 cards

STS-12C aid for OC-12 cards

STS-{1-6,12-17}-{1,4,7,10}

STS-3C aid for OC-3 and OC-12 cards

STS-{1-6,12-17}-{1-12}

STS-1 aid for OC-12, EC-1, DS-3 and OC-3 cards

STS-{1-6,12-17}-{1-6}

STS-1 aid for DS3XM cards

STS-{5,6,12,13}-{1,13,25,37}

STS-12C for OC-48

STS-{5,6,12,13}-{1,4,7,10,13,16,19,22,
25,28,31,34,37,40,43,46}

STS-3C for OC-48

STS-{5,6,12,13}-{1-48}

STS-1 for OC-48

STS-{5,6,12,13}-{1}

STS-48C for OC-48


11.12.7 syn_src

Synchronization source

Table 11-20 sync_src

Pattern
Description

FAC-{1-6,12-17}-1

Sync source is the optical card (OC-12) facility

FAC-{1-6,12-17}-{1-4}

Sync source is the optical card (OC-3) facility

FAC-{5,6,12,13}-1

Sync source is the optical card (OC-48) facility

INTERNAL

Set the syn_src to be the system default value

SYNC-NE

Sync-NE source

SYNC-{BITS1,BITS2}

SYNC-BITS1 or SYNC-BITS2 sync source


11.12.8 sync_ref

Synchronization aids

Table 11-21 sync_ref 

Pattern
Description

SYNC-NE

NE sync aid

SYNC-{BITS1,BITS2}

BITS1 and BITS2 sync aids


11.12.9 vt1_5

Virtual termination aids

Table 11-22 vt1_5

Pattern
Description

VT1-{1-6,12-17}-1-{1-14}

DS-1 vts

VT1-{1-6,12-17}-{1-12}-{1-28}

OC-12, OC-3, EC-1 vts

VT1-{1-6,12-17}-{1-6}-{1-28}

DS3XM vts

VT1-{5,6,12,13}-{1-48}-{1-28}

OC-48 vts


11.13 Parameter Types

This section provides a description of all message parameter types defined for the TL1 messages used in the ONS 15454. The TL1 message descriptions frequently refer to this section.

11.13.1 ATAG Description

The Autonomous Message Tag (ATAG) is used for message sequencing. The number is incremented by one for each autonomous message sent by the ONS 15454. The ONS 15454 uses whole numbers 0000 to 9999.

11.13.2 CTAG Description

The Correlation tag is included in each command by the user and is repeated by the ONS 15454 in the response to allow the user to associate the command and response messages.


Note   The valid values for a ctag are decimal numbers with a maximum of 6 digits in Release 2.2.1.


11.13.3 TID Description

The Target Identifier is the name of the NE where the command is addressed. TID is the Telcordia name for the system.

11.13.4 ALL_MONTYPE

Monitoring type list

Table 11-23 ALL_MONTYPE Values

ALL_MONTYPE Values
Description

AISSP

Alarm Indication Signal Seconds-Path

CVCPP

Coding Violations - CP-Bit Path

CVL

Coding Violations - Line

CVP

Coding Violations - Path

CVV

Coding Violations - Section

ESCPP

Errored Seconds - CP-Bit Path

ESL

Errored Seconds - Line

ESP

Errored Seconds - Path

ESV

Errored Seconds - VT Path

FCL

Failure Count - Line

FCP

Failure Count - Path

LOSSL

Loss of Signal Seconds - Line

NPJC-PDET

PPJC-PDET:Negative Pointer Justification

NPJC-PGEN

PPJC-PDEN:Negative Pointer Justification

PPJC-PDET

PPJC-PDET:Positive Pointer Justification

PPJC-PGEN

PPJC-PDEN:Positive Pointer Justification

PSC

Protection Switching Count

PSD

Protection Switching Duration

SASCPP

Severely Errored Framing/AIS Second - CP-Bit Path

SASP

Severely Errored Framing/AIS Seconds

SEFS

Severely Errored Framing Seconds

SESCPP

Severely Errored Second - CP-Bit Path

SESL

Severely Errored Second - Line

SESP

Severely Errored Second - Path

SESV

Severely Errored Second - VT Path

UASCPP

Unavailable Second - CP-Bit Path

UASL

Unavailable Second - Line

UASP

Unavailable Second - Path

UASV

Unavailable Second - VT Path


11.13.5 ALL_THR

Threshold list

Table 11-24 ALL_THR Value

ALL_THR Values
Description

T-AISSP

Alarm Indication Signal Seconds-Path

T-CVCPP

Coding Violations - CP-Bit Path

T-CVL

Coding Violations - Line

T-CVP

Coding Violations - Path

T-CVS

Coding Violations - Section

T-CVV

Coding Violations - VT Path

T-ESCPP

Errored Seconds - CP-Bit Path

T-ESL

Errored Seconds - Line

T-ESP

Errored Seconds - Path

T-ESS

Errored Seconds - Section

T-ESV

Errored Seconds - VT Path

T-FCL

Failure Count - Line

T-FCP

Failure Count - Path

T-LOSSL

Loss of Signal Seconds - Line

T-PJNEG

PPJC-PDET:Negative Pointer Justification

T-PJNEG-GEN

PPJC-PGEN:Negative Pointer Justification

T-PJPOS

PPJC-PDET:Positive Pointer Justification

T-PJPOS-GEN

PPJC-PGEN:Positive Pointer Justification

T-PSC

Protection Switching Count

T-PSD

Protection Switching Duration

T-SASCPP

Severely Errored Framing/AIS Second - CP-Bit Path

T-SASP

Severely Errored Framing/AIS Seconds

T-SEFS

Severely Errored Framing Seconds

T-SESCPP

Severely Errored Second - CP-Bit Path

T-SESL

Severely Errored Second - Line

T-SESP

Severely Errored Second - Path

T-SESS

Severely Errored Second - Section

T-SESV

Severely Errored Second - VT Path

T-UASCPP

Unavailable Second - CP-Bit Path

T-UASL

Unavailable Second - Line

T-UASP

Unavailable Second - Path

T-UASV

Unavailable Second - VT Path


11.13.6 CCT

Defines the type of cross-connect to be created.

Table 11-25 CCT Values

CCT Values
Description

1WAY

A unidirectional connection from a source tributary to a destination tributary

2WAY

A bidirectional connection between the two tributaries

MON

Monitored cross connection


11.13.7 COND_EFF

The affected unit's condition

Table 11-26 COND_EFF Values

COND_EFF Values
Description

CL

Standing condition cleared

SC

Standing condition raised

TC

Transient condition


11.13.8 CONDITION

The condition type of the alarm indication

Table 11-27 CONDITION Values 

CONDITION Values
Description

ACOMAN

Alarm cutoff is in manual mode

AIS

External failure - Incoming - Alarm Indication Signal

AIS-L

External failure - Incoming - Alarm Indication Signal - Line

AIS-P

External failure - Incoming - Alarm Indication Signal - Path

AIS-V

External failure - Incoming - Alarm Indication Signal - VT layer

APSB

External failure - Incoming - Automatic Protection Switching Channel - Byte failure

APSC

External failure - Incoming - Automatic Protection Switching Channel failure

APSC-IMP

External failure - Incoming - Automatic Protection Switching - Invalid K bytes

APSCCONNL

External failure - Incoming - Automatic Protection Switching - Connection Loss

APSCDFLTK

External failure - Incoming - Automatic Protection Switching - Default K byte

APSCINCON

External failure - Incoming - Automatic Protection Switching - Inconsistent

APSCM

External failure - Incoming - Automatic Protection Switching Channel - Protection Switching Channel Match failure

APSCNMIS

APS Channel - BLSR - Node ID Mismatch

APSMM

External failure - Incoming - Automatic Protection Switching Channel - Automatic Protection Switch Mode Mismatch

AUTOLSROFF

Internal hardware - Facility Termination Equipment - Automatic Laser Shutdown

AUTORESET

Recovery action - Automatic System Reset

AUTOSW-AIS

Automatic Switch - Alarm Indication Signal

AUTOSW-LOP

Automatic Switch - Loss of Pointer

AUTOSW-PDI

Automatic Switch - Payload Defect Indication

AUTOSW-SDBER

Automatic Switch - Signal Degrade Bit Error Rate

AUTOSW-SFBER

Automatic Switch - Signal Fail Bit Error Rate

AUTOSW-UNEQ

Automatic Switch - Unequipped

BKUPMEMP

Internal hardware - Control Equipment - Primary Non-Volatile Backup Memory Failure

BKUPMEMS

Internal hardware - Control Equipment - Secondary Non-Volatile Backup Memory Failure

BLSR-RESYNC

Bidirectional Line Switched Ring - Tables Resynchronized

BLSROOSYNC

Bidirectional Line Switched Ring - Out of Sync

BPV

External failure - Incoming - Bipolar Violation

CARLOSS

External failure - Incoming - Carrier Loss on the LAN

CLDRESTART

Recovery action - Cold Restart

CONCAT

STS Concatenation Error

CONTBUS

Control Bus Failure

CONTBUS-1

Control Bus Failure - 1

CONTBUS-2

Control Bus Failure - 2

CONTBUS-A-1

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 1

CONTBUS-A-2

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 2

CONTBUS-A-3

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 3

CONTBUS-A-4

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 4

CONTBUS-A-5

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 5

CONTBUS-A-6

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 6

CONTBUS-A-7

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 7

CONTBUS-A-8

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 8

CONTBUS-A-9

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 9

CONTBUS-A-10

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 10

CONTBUS-A-11

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 11

CONTBUS-A-12

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 12

CONTBUS-A-13

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 13

CONTBUS-A-14

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 14

CONTBUS-A-15

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 15

CONTBUS-A-16

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 16

CONTBUS-A-17

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 17

CONTBUS-A-18

TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 18

CONTBUS-B-1

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 1

CONTBUS-B-2

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 2

CONTBUS-B-3

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 3

CONTBUS-B-4

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 4

CONTBUS-B-5

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 5

CONTBUS-B-6

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 6

CONTBUS-B-7

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 7

CONTBUS-B-8

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 8

CONTBUS-B-9

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 9

CONTBUS-B-10

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 10

CONTBUS-B-11

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 11

CONTBUS-B-12

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 12

CONTBUS-B-13

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 13

CONTBUS-B-14

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 14

CONTBUS-B-15

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 15

CONTBUS-B-16

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 16

CONTBUS-B-17

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 17

CONTBUS-B-18

TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 18

CONTCOM

Internal hardware - Control Equipment - Control Communications equipment failure

CONTEQPT

Internal hardware - Control Equipment failure

CONTR

Internal hardware - Control Equipment - Control processor failure

CTNEQPT

Internal hardware - Interconnection Equipment failure

CTNEQPT-PB1PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 1

CTNEQPT-PB1WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 1

CTNEQPT-PB2PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 2

CTNEQPT-PB2WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 2

CTNEQPT-PB3PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 3

CTNEQPT-PB3WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 3

CTNEQPT-PB4PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 4

CTNEQPT-PB4WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 4

CTNEQPT-PB5PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 5

CTNEQPT-PB5WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 5

CTNEQPT-PB6PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 6

CTNEQPT-PB6WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 6

CTNEQPT-PB12PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 12

CTNEQPT-PB12WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 12

CTNEQPT-PB13PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 13

CTNEQPT-PB13WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 13

CTNEQPT-PB14PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 14

CTNEQPT-PB14WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 14

CTNEQPT-PB15PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 15

CTNEQPT-PB15WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 15

CTNEQPT-PB16PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 16

CTNEQPT-PB16WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 16

CTNEQPT-PB17PROT

Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 17

CTNEQPT-PB17WORK

Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 17

DATAFLT

Internal Error - Software Fault - Data integrity fault

EOC

Embedded Operations Channel (Section DCC) failure

EOC-DOWN

Embedded Operation Channel Fail

EQPT

Internal hardware - Critical alarm caused by equipment failure

EQPT-DIAG

Equipment failure - Diagnostics Failure

EQPT-FAIL

Equipment Failure - Board Failure

EQPT-MAC

Equipment Failure - Medium Access Control

ESW

External Error - Excessive Switching

EXCCOL

External Failure - Incoming - Excess collisions on the LAN

EXT

Failure Detected External to the NE

EXTERR

External Error

FA

Internal Hardware - Power Failure - Fuse Alarm

FAC

External failure - Incoming - Facility, critical alarm caused by DS-3 facility failure

FACTERM

Internal hardware - Facility Termination equipment failure

FAILTORLS

Internal hardware - Failure To Release from protection

FAILTOSW

Internal hardware - Failure To Switch to protection

FAILTOSW-PATH

Failure to switch from the working path to the protection path on a UPSR

FAILTOSWR

Failure to Switch to Protection in a Ring

FAILTOSWS

Failure to Switch to Protection in a Span

FAN

Fan Tray Failure

FE-AIS

Far-end DS-3 node is reporting an AIS

FE-DS1-MULTLOS

Multiple inputs detect a loss on the far-end

FE-DS1-NSA

Non-service affecting failure detected from the far-end DS-1

FE-DS1-SA

Service affecting failure detected from the far-end DS-1

FE-DS1-SNGLLOS

One of the DS-1 inputs on the far-end detects a LOS

FE-DS3-NSA

Non-service affecting failure detected from the far-end DS-3

FE-DS3-SA

Service affecting failure detected from the far-end DS-3

FE-EQPT-NSA

Non-service affecting equipment failure is detected from the far-end DS-3

FE-IDLE

Far-end node detects an idle DS-3 signal

FE-LOF

Far-end node reports a DS-3 loss of frame

FE-LOS

Far-end node reports a DS-3 loss of signal

FEBE

External failure - Incoming - Far End Block Error

FEPRLF

External failure - Incoming - Automatic Protection Switching Channel - Far End Protection Line Failure

FORCED-REQ

Forced switch request on facility/equipment

FRCDWKSWBK

Recovery action - Working facility/equipment forced to switch back to working

FRCDWKSWPR

Recovery action - Working facility/equipment forced to switch to protection unit

FRCDWKSWPR-PATH

Recovery action - Working facility/equipment forced to switch to protection unit - Path

FRCWKBK-R

Recovery action - Working facility/equipment forced to switch back to working - Ring

FRCWKBK-S

Recovery action - Working facility/equipment forced to switch back to working - Span

FRCWKPR-R

Recovery action - Working facility/equipment forced to switch to protection unit- Ring

FRCWKPR-S

Recovery action - Working facility/equipment forced to switch to protection unit- Span

FRNGSYNC

Free Running Synchronization mode

FSTSYNC

Fast Start Synchronization Mode

HITEMP

Internal hardware - Equipment failure - High temperature

HLDOVRSYNC

Holdover synchronization mode

IMPROPRMVL

Procedural Error - Improper Removal

INC

Incoming failure condition

INC-ISD

Incoming failure condition - Idle Signal Path

INIT

Recovery action - Initialization initiated

INT

Internal hardware fault or failure

INTERR

Error Internal to the NE Detected

INTMSGERR

Internal Error - Internal Message Error

INTSFT

Internal Error - Software Fault or failure

INVMACADR

Equipment Failure - Invalid MAC address

LKOUTPR-R

Lockout or Protection - Ring

LKOUTPR-S

Lockout or Protection - Span

LKOUTWK-R

Lockout of Working - Ring

LKOUTWK-S

Lockout of Working - Span

LOCKOUT-REQ

Lockout switch request on facility/equipment

LOCKOUTOFPR

Recovery action - Lockout of Protection

LOCKOUTOFPR-PATH

Recovery action - Lockout of Protection - Path

LOCKOUTOFWK

Recovery action - Lockout of working

LOF

External failure - Incoming - Loss of Frame

LOP

External failure - Incoming - Loss of Pointer

LOP-P

External failure - Incoming - Loss of Pointer - Path

LOP-V

Loss of pointer at the VT level

LOS

External failure - Incoming - Loss of Signal

LPBK

Loopback

LPBKDS1FEAC

DS-1 loopback signal is received from the far-end due to a Far-End Alarm and Control (FEAC) command

LPBKDS1FEAC-CMD

DS-1 loopback command sent by the ONS 15454 to the far-end equipment

LPBKDS3FEAC

DS-3 loopback signal is received from the far-end due to a Far-End Alarm and Control (FEAC) command

LPBKDS3FEAC-CMD

DS-3 loopback command sent by the ONS 15454 to the far-end equipment

LPBKFACILITY

Loopback, Facility

LPBKM23

DS-2 Loopback due to Far End Command

LPBKM23-CMD

DS-2 Loopback Command sent to Far End

LPBKNETWORK

Loopback, Network

LPBKTERMINAL

Loopback, Terminal

MAN

Manually caused abnormal condition

MAN-REQ

Manual Switch Request

MANRESET

Recovery action - Manual system Reset

MANSWTOINT

Recovery action - Manual synchronization switch to internal clock

MANSWTOPRI

Recovery action - Manual synchronization Switch To Primary reference

MANSWTOSEC

Recovery action - Manual synchronization Switch To Second reference

MANSWTOTHIRD

Recovery action - Manual synchronization Switch To Third reference

MANSWTOFOURTH

Recovery action - Manual synchronization Switch To Fourth reference

MANSWTOFIFTH

Recovery action - Manual synchronization Switch To Fifth reference

MANSWTOSIXTH

Recovery action - Manual synchronization Switch To Sixth reference

MANWKBK-R

Manual Switch of working facility/equipment to protection - Ring

MANWKBK-S

Manual Switch of working facility/equipment to protection - Span

MANWKPR-R

Manual Switch of working facility/equipment to protection unit - Ring

MANWKPR-S

Manual Switch of working facility/equipment to protection unit - Span

MANWKSWBK

Recovery action - Manual Switch or working facility/equipment to protection

MANWKSWPR

Recovery action - Manual Switch of Working facility/equipment to protection unit

MANWKSWPR-PATH

Recovery action - Manual Switch of Working facility/equipment to protection - Path

MEA

Internal error - Mismatch of Equipment and Attributes

MEM-GONE

Software operations exceed the memory capacity of the TCC/TCC+ card

MEM-LOW

Data generated by software operations is close to exceeding the memory capacity of the TCC/TCC+ card

NEW-ROOT

New root trap in BRIDGE-MIB

NORMAL

Normal condition - This condition type is used by the NE to report the returning to normal from a previous off-normal condition

OG

External failure - Outgoing failure condition

OOF

External failure - Incoming - Out of Frame

PATHSEL

External failure - Incoming - Path Selector inability to switch to a valid signal

PDI

External failure - Incoming - Signal Label Mismatch Failure - Payload Defect Indication

PDI-P

External failure - Incoming - Signal Label Mismatch Failure - Payload Defect Indication - Path

PEERMISSM

Peer state mismatch

PLM-P

External failure - Incoming - Signal Label Mismatch Failure - Payload Label Mismatch - Path

PLM-V

Content of the V5 byte in the SONET overhead is inconsistent or invalid

PLUG-IN

Internal hardware - Equipment unit plug-in

PM-TCA

Performance Monitoring - Threshold Crossing Alert

PRC-DUPID

Procedural Error - Duplicate Node ID

PRCDRERR

Procedural Error

PROGFLT

Internal Error - Software Fault - Program failure

PROTNA

Protection unit not available

PS

Occurrence of a protection switching event

PWR

Internal hardware - Power failure (detected internal to NE)

PWRRESTART

Recovery action - Powerfail Restart

RAI

External failure - Incoming - Remote Alarm Indication

RCVR

Internal hardware - Facility Termination equipment - Receiver failure

RCVR-MISS

Facility termination equipment detects a missing receive cable on the DS-1 port or a possible mismatch of backplane equipment

RCVRY

Recovery or service protection action has been initiated

RDI-L

External failure - Outgoing - Remote Defect Indication - Line

RDI-P

External failure - Outgoing - Remote Defect Indication - Path

RFI

External failure - Incoming - Remote Failure Indication

RFI-L

External failure - Incoming - Remote Failure Indication - Line

RFI-P

External failure - Incoming - Remote Failure Indication - Path

RFI-V

Upstream failure has occurred at the VT layer

RMON-ALARM

An RMON Alarm

RMON-RESET

RMON histories and alarms have been reset due to chipset reboot

SD

Facility has passed BER Threshold for Signal Degrade

SEF

External failure - Incoming - Severely Errored Frame

SF

Facility has passed BER threshold for Signal Failure

SLMF

External failure - Incoming - Signal Label Mismatch Failures - SONET

SQUELCH

Ring is isolated into two or more segments

SSM-DUS

Synchronization Status Messaging - Don't use for timing synchronization

SSM-FAIL

Synchronization Status Messaging - Failed

SSM-OFF

Synchronization Status Messaging - Off

SSM-PRS

Synchronization Status Messaging - Primary reference source - Stratum 1

SSM-RES

Synchronization Status Messaging - Reserved - quality level set by user

SSM-SMC

Synchronization Status Messaging - SONET minimum clock

SSM-ST2

Synchronization Status Messaging - Stratum 2

SSM-ST3

Synchronization Status Messaging - Stratum 3

SSM-ST3E

Synchronization Status Messaging - Stratum 3E

SSM-ST4

Synchronization Status Messaging - Stratum 4

SSM-STU

Synchronization Status Messaging - Sync traceability unknown

SSM-TNC

Synchronization Status Messaging - Transit node clock

SWFTDWN

Recovery action - Software download in progress

SWTOINT

Recovery action - Synchronization Switch To Internal clock

SWTOPRI

Recovery action - Synchronization Switch To Primary reference

SWTOSEC

Recovery action - Synchronization Switch To Second reference

SWTOTHIRD

Recovery action - Synchronization Switch To Third reference

SWTOFOURTH

Recovery action - Synchronization Switch To Fourth reference

SWTOFIFTH

Recovery action - Synchronization Switch To Fifth reference

SWTOSIXTH

Recovery action - Synchronization Switch To Sixth reference

SYNC

External failure - Incoming - Loss of timing on Synchronization link.

SYNCCLK

Internal hardware - Synchronization unit failure

SYNCEQPT

Internal hardware - Synchronization switching Equipment failure

SYNCOOS

External failure - Incoming - Loss of timing on all specified synchronization links

SYNCPRI

External failure - Incoming - Loss of timing on primary synchronization link

SYNCSEC

External failure - Incoming - Loss of timing on secondary synchronization link

SYNCTHIRD

External failure - Incoming - Loss of timing on third synchronization link

SYNCFOURTH

External failure - Incoming - Loss of timing on fourth synchronization link

SYNCFIFTH

External failure - Incoming - Loss of timing on fifth synchronization link

SYNCSIXTH

External failure - Incoming - Loss of timing on sixth synchronization link

SYSBOOT

Activation of new software

TOP-CHANGE

Topology Change trap in BRIDGE-MIB

TRMT

Internal hardware - Facility Termination equipment - Transmit failure

TRMT-MISS

Facility termination equipment detects a missing transmit cable on the DS-1 port or a possible mismatch of backplane equipment

TSI

Internal hardware - Interconnection Equipment - Time slot interchange equipment failure

UNEQ-P

External failure - Incoming - Signal Label Mismatch Failure - Unequipped - Path

UNEQ-V

VT is receiving an unequipped signal

UNPLUG

Internal hardware - Equipment unit un-plug

WATM-TO

Internal Error - Watchdog Timer Timeout

WKGMEM

Internal hardware - Control Equipment -Working memory failure

WKSWBK

Recovery action - Working facility/equipment switched back to working

WKSWPR

Recovery action - Working facility/equipment switched to protection unit

WRMRESTART

Recovery action - Warm Restart

WTR

Recovery action - SONET line is in Wait To Restore state


11.13.9 DIRECTION

Transmit and receive directions

Table 11-28 DIRECTION Values

DIRECTION Values
Description

BTH

Both transmit and receive directions

RCV

Receive direction only

TRMT

Transmit direction only


11.13.10 DS3_FMT

Indicates a DS-3 digital signal format

Table 11-29 DS3_FMT Values

DS3_FMT Values
Description

ASYNC

The DS-3 digital signal format is ASYNC

CBIT

The DS-3 digital signal format is C-BIT

SYNC

The DS-3 digital signal format is SYNC

UNFR

The DS-3 digital signal format is unframed


11.13.11 DS_LINE_CODE

DS-123 Line Code

Table 11-30 DS_LINE_CODE Values

DS_LINE_CODE Values
Description

B3ZS

Bipolar with Three-Zero Substitution


11.13.12 DS_LINE_TYPE

DS-123 Line type

Table 11-31 DS_LINE_TYPE Values

DS_LINE_TYPE Values
Description

C-BIT

C-BIT line type applies to DS3XM card

M23

M23 line type applies to DS3XM card

UNFRAMED

Line Type is Unframed


11.13.13 DX_MODE_OP

Duplex switch operation mode

Table 11-32 DX_MODE_OP Values

DX_MODE_OP Values
Description

FRCD

Forced Switch

MAN

Manual Switch


11.13.14 E_LBO

Electrical signal line buildout

Table 11-33 E_LBO Values

E_LBO Values
Description

0-225

Electrical signal buildout range is 0-255

226-450

Electrical signal buildout range is 255-450


11.13.15 ENV_ALM

Environmental alarm types as defined by Telcordia GR-833-CORE, Issue 2, November 1996, Appendix F.

Table 11-34 ENV_ALM Values 

ENV_ALM Values
Description

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUSE

Fuse failure

GEN

Generator failure

HIAIR

High airflow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48 Volt power supply failure

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

SMOKE

Smoke

TOXICGAS

Toxic gas

VENTN

Ventilation system failure


11.13.16 ENV_CTL

Environmental control types as defined by Telcordia GR-833-CORE, Issue 2, November 1996, Appendix G.

Table 11-35 ENV_CTL Values

ENV_CTL Values
Description

AIRCOND

Air conditioning

ENGINE

Engine

FAN

Fan

GEN

Generator

HEAT

Heat

LIGHT

Light

MISC

Miscellaneous

SPKLR

Sprinkler


11.13.17 EQPT_TYPE

Identifies the type of equipment being provisioned into a slot.

Table 11-36 EQPT_TYPE Values 

EQPT_TYPE Values
Description

AIC

The Alarm Interface Controller Card is an optional card which expands system management capabilities for the customer defined alarm I/O and orderwire functionality

DCC

The Data Communications Channel communicates network management information

DS1-14

A 14 port interface card supporting DS-1 facilities

DS1N-14

A 14 port interface card supporting DS-1 facilities

DS3-12

A 12 port interface card supporting DS-3 facilities

DS3CR-12

Cost reduced DS-3

DS3N-12

A 12 port interface card supporting DS-3 facilities

DS3XM-6

An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s

E1000T-2

A two port interface card supporting 1000 Base T ethernet facilities

E100T-12

A 12 port interface card supporting 100 Base T ethernet facilities

EC1-12

A 12 port interface card supporting EC-1 facilities

EC1N-12

A 12 port interface card supporting EC-1 facilities

OC-12

An interface card that supports one or more OC-12 (622Mbs) optical facilities

OC12-IR-1

An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities

OC12-LR-1

An interface card that supports one long range OC-12 (622Mbs) optical facilities

OC12-SR-1

An interface card that supports one short range OC-12 (622Mbs) optical facilities

OC192-LR-1

An interface card that supports one or more long range OC-192 optical facilities

OC-3

An interface card that supports multiple OC-3 (155Mbs) optical facilities

OC3-IR-4

An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities

OC3-SR-4

An interface card that supports four short range OC-3 (155Mbs) optical facilities

OC-48

An interface card that supports one or more OC-48 (10Gbs) optical facilities

OC48-IR-1

An interface card that supports one intermediate range OC-48 (10Gbs) optical facilities

OC48-LR-1

An interface card that supports one long range OC-48 (10Gbs) optical facilities

OC48-SR-1

An interface card that supports one short range OC-48 (10Gbs) optical facilities

TCC

The Timing, Communication and Control card

TCC+

The Timing, Communication and Control+ card

XC

A Cross-Connect card

XC-192

A Cross-Connect card

XC-VT

A Cross-Connect card


11.13.18 EQUIP

Indicates the presence of a plug-in unit

Table 11-37 EQUIP Values

EQUIP Values
Description

EQUIP

The unit is Equipped - present

UNEQUIP

The unit is Unequipped - absent


11.13.19 EQUIPMENT_TYPE

Table 11-38 EQUIPMENT_TYPE Values

EQUIPMENT_TYPE Values
Description

AIC

AIC card

DS-1

DS-1 card

DS-1N

DS-1N card

DS-3

DS-3 card

DS-3N

DS-3N card

DS3XM

DS3XM card

E-100T

E-100T card

E-1000T

E-1000T card

EC-1

EC-1 card

EC-1N

EC-1N card

OC-12

OC-12 card

OC-3

OC-3 card

OC-48

OC-48 card

TCC

TCC card

TCC+

TCC+ card

XC-STS

XC-STS card

XC-VT

XC-VT card


11.13.20 EXT_RING

Indicates if the ring supports the extended K1/K2/K3 protocol.

Table 11-39 EXT_RING Values

EXT_RING Values
Description

N

Indicates the Ring does not support the extended K1/K2/K3 protocol

Y

Indicates the Ring does support the extended K1/K2/K3 protocol


11.13.21 FRAME_FORMAT

The frame format for a T1 port

Table 11-40 FRAME_FORMAT Values

FRAME_FORMAT Values
Description

D4

Frame format is D4

ESF

Frame format is ESF

UNFRAMED

Frame format is unframed


11.13.22 LINE_BUILDOUT

Table 11-41 LINE_BUILDOUT Values

LINE_BUILDOUT Values
Description

0-131

Line buildout range is 0-131

132-262

Line buildout range is 132-262

263-393

Line buildout range is 263-393

394-524

Line buildout range is 394-524

525-655

Line buildout range is 525-655


11.13.23 LINE_CODE

Table 11-42 LINE_CODE Values

LINE_CODE Values
Description

AMI

Line code value is AMI

B8ZS

Line code value is B8ZS (Bipolar with Eight-Zero Substitution)


11.13.24 LOCATION

Identifies the location where the action is to take place

Table 11-43 LOCATION Values

LOCATION Values
Description

FEND

Action occurs on the Far End of the facility

NEND

Action occurs on the Near End of the facility


11.13.25 LPBK_TYPE

Indicates the type of loopback that is to be operated or released

Table 11-44 LPBK_TYPE Values

LPBK_TYPE Values
Description

FACILITY

A type of loopback that connects the incoming received signal immediately following the optical-to-electrical conversion (before descrambling) to the associated transmitter in the return direction

TERMINAL

A loopback that connects the signal that is about to be transmitted (after scrambling but before the electrical-to-optical conversion) is connected to the associated, incoming receiver


11.13.26 MOD2

A generic object type

Table 11-45 MOD2 Values

MOD2 Values
Description

DS-1

DS-1 facility on DS3XM

EC-1

EC-1 facility

OC-12

OC-12 facility

OC-3

OC-3 facility

OC-48

OC-48 facility

STS-1

STS path

STS-12C

STS path

STS-3C

STS path

STS-48C

STS path

T1

DS-1 facility

T3

DS-3 facility

VT1

VT1 path


11.13.27 MOD2ALM

Alarm type for certain generic TL1 commands

Table 11-46 MOD2ALM Values

MOD2ALM Values
Description

DS-1

DS-1 alarm

E-100

E-100 alarm

E-1000

E-1000 alarm

EC-1

EC-1 alarm

OC-12

OC-12 alarm

OC-3

OC-3 alarm

OC-48

OC-48 alarm

STS-1

STS-1 alarm

STS-12C

STS-12C alarm

STS-3C

STS-3C alarm

STS-48C

STS-48C alarm

T1

T1 alarm

T3

T3 alarm

VT1

VT1 alarm


11.13.28 MOD2B

Alarm type for certain generic TL1 commands

Table 11-47 MOD2B Values

MOD2B Values
Description

BITS

BITS alarm

COMM

COMM alarm

DS-1

DS-1 alarm

E-100

E-100 alarm

E-1000

E-1000 alarm

EC-1

EC-1 alarm

ENV

ENV alarm

EQPT

EQPT alarm

OC-12

OC-12 alarm

OC-3

OC-3 alarm

OC-48

OC-48 alarm

STS-1

STS alarm

STS-12C

STS alarm

STS-3C

STS alarm

STS-48C

STS alarm

SYNCN

SYNCN alarm

T1

T1 alarm

T3

T3 alarm

TCC

TCC alarm

TCC+

TCC+ alarm

VT1

VT alarm


11.13.29 MODIFIER

Modifier for certain TL1 commands that are generic in their syntax

Table 11-48 MODIFIER Values 

MODIFIER Values
Description

BITS

BITS command modifier

EQPT

Equipment command modifier

OC-12

OC-12 command modifier

OC-3

OC-3 command modifier

OC-48

OC-48 command modifier

STS-1

STS-1 command modifier

STS-12C

STS-12c command modifier

STS-3C

STS-3c command modifier

SYNCN

Synchronization command modifier

T3

T3/DS-3 command modifier


11.13.30 NOTIF_CODE

The 2-character Notification Code associated with an autonomous message

Table 11-49 NOTIF_CODE Values

NOTIF_CODE Values
Description

CL

The condition causing the alarm has Cleared

CR

A Critical alarm

MJ

A Major alarm

MN

A Minor alarm

NA

The condition is Not Alarmed

NR

The alarm is not reported


11.13.31 OCN_MONTYPE

OCN monitor type

Table 11-50 OCN_MONTYPE Values

OCN_MONTYPE Values
Description

CVL

Coding Violation - Line

ESL

Errored Second - Line

PJNEG

PPJC-PDET:Negative Pointer Justification

PJPOS

PPJC-PGEN:Negative Pointer Justification

PSC

Protection Switching Count

PSD

Protection Switching Duration

SEFS

Severely Errored Framing Seconds

UASL

Unavailable Second - Line


11.13.32 OCN_TYPE

Modifier used to differentiate the various levels of OC-N in the ENT/ED/DLT commands

Table 11-51 OCN_TYPE Values

OCN_TYPE Values
Description

OC-12

Optical Carrier level-12 (622Mbs)

OC-3

Optical Carrier level-3 (155Mbs)

OC-48

Optical Carrier level-48 (2.4Gbs)


11.13.33 ON_OFF

Disable or Enable Mode

Table 11-52 ON_OFF Values

ON_OFF Values
Description

OFF

Mode is disabled

ON
Mode is enabled

11.13.34 OPTICAL_MODE

Table 11-53 OPTICAL_MODE Values

OPTICAL_MODE Values
Description

SDH

The SDH optical mode the European format

SONET

The SONET optical mode the American format


11.13.35 PRIVILEGE

Security level

Table 11-54 PRIVILEGE Values

PRIVILEGE Values
Description

MAINT

Maintenance Security Level

PROV

Provision Security Level

RTRV

Retrieve Security Level

SUPER

Superuser Security Level


11.13.36 PROT_MOD_OP

Protection switch operation mode

Table 11-55 PROT_MOD_OP Values

PROT_MOD_OP Values
Description

FRCD

Force switch operation mode

MAN

Manual switch operation mode


11.13.37 PROTECTION_GROUP

Table 11-56 PROTECTION_GROUP Values

PROTECTION_GROUP Values
Description

1-1

1 to 1 protection group

1-N

1 to N protection group


11.13.38 PST

Primary State of the entity (e.g. facility)

Table 11-57 PST Values

PST Values
Description

IS

In-service

OOS

Out-of-Service


11.13.39 REVERTIVE_TIME

Table 11-58 REVERTIVE_TIME Values

REVERTIVE_TIME Values
Description

0.0 - 12.0

Revertive time is 0.0 to 12.0 minutes


11.13.40 REVERTIVE_TYPE

Table 11-59 REVERTIVE_TYPE Values

REVERTIVE_TYPE Values
Description

NR

Revertive type is disabled

R

Revertive type is enabled


11.13.41 RNG_TYPE

Defines the type of ring that is to be deployed for this path

Table 11-60 RNG_TYPE Values

RNG_TYPE Values
Description

BLSR2

2-Fiber Bidirectional Line Switched Ring

BLSR4

4-Fiber Bidirectional Line Switched Ring

UPSR

Unidirectional Path Switched Ring


11.13.42 SD_BER

The threshold for declaring Signal Degrade on a facility or path

Table 11-61 SD_BER Values

SD_BER Values
Description

1E-5 - 1E-9

SDBER is the 1E-5 to 1E-9


11.13.43 SDCC_MODE

Enables or disables the Section Data Communications Channel (SDCC) for the specified facility

Table 11-62 SDCC_MODE Values

SDCC_MODE Values
Description

N

Section Data Communications Channel is disabled for this facility

Y

Section Data Communications Channel is enabled for this facility


11.13.44 SERV_EFF

Indicates the effect of the alarm on service

Table 11-63 SERV_EFF Values

SERV_EFF Values
Description

NSA

The condition is Non-Service Affecting

SA

The condition is Service Affecting


11.13.45 SF_BER

The threshold for declaring Signal Failure on a facility or path

Table 11-64 SF_BER Values

SF_BER Values
Description

1E-3 - 1E-5

SFBER is the 1E-3 to 1E-5


11.13.46 SIDE

The role the unit is playing in the protection group

Table 11-65 SIDE Values

SIDE Values
Description

PROT

The entity is the protection unit in the protection group

WORK

The entity is a working unit in the protection group


11.13.47 STATE

The provisioned state of the equipment unit or facility

Table 11-66 STATE Values

STATE Values
Description

IS

The entity is InService

OOS-AS

The entity is Out-Of-Service and Assigned

OOS-UAS

The entity is Out-Of-Service and UnAssigned


11.13.48 STATUS

Indicates whether the unit in the pair is Active or Standby

Table 11-67 Status Values

STATUS Values
Description

ACT

The entity is the Active unit in the protection group

NA

Status is unavailable

STBY

The entity is the standby unit in the protection group


11.13.49 STM_TYPE

The Synchronous Transport Mode of the NE

Table 11-68 STM_TYPE Values

STM_TYPE Values
Description

SDH

The NE is operating in Synchronous Digital Hierarchy mode

SONET

The NE is operating in Synchronous Optical NETwork mode


11.13.50 STS_MONTYPE

Table 11-69 STS_MONOTYPE Values

STS_MONTYPE Values
Description

CVP

Coding Violation - P

ESP

Errored Second - Path

SESP

Severely Errored Second - Path

UASP

Unavailable Second - Path


11.13.51 STS_PATH

Modifier for some of the STS commands

Table 11-70 STS_PATH Values

STS_PATH Values
Description

STS-1

Synchronous Transport Signal level-1 (51Mbs)

STS-12C

Synchronous Transport Signal level-12 Concatenated (622Mbs)

STS-3C

Synchronous Transport Signal level-3 Concatenated (155Mbs)


11.13.52 SWITCH

The type of switch to be initiated

Table 11-71 SWITCH Values

SWITCH Values
Description

FRCD

Force a switch unless another FRCD or LOCKOUT is in effect

LOCKOUT

Locks the facility out of switching. The system cannot switch to the protect facility to carry service

MAN

Requests a manual switch of the facility


11.13.53 SYNC_GENERATION

Synchronization status message set generation

Table 11-72 SYNC_GENERATION Values

SYNC_GENERATION Values
Description

GEN1

First generation SSM set

GEN2

Second generation SSM set


11.13.54 SYNC_MODE

Table 11-73 SYNC_MODE Values

SYNC_MODE Values
Description

FRNG

Reset operation mode

FST

Reset operation mode

HLDOVR

Reset operation mode

NORM

Reset operation mode


11.13.55 SYNC_QUALITY_LEVEL

Reserved for network synchronization quality level

Table 11-74 SYNC_QUALITY_LEVEL Values

SYNC_QUALITY_LEVEL Values
Description

ABOVE-PRS

Better than Primary Reference Source

ABOVE-SMC

Between SMC and ST3

ABOVE-ST2

Between ST2 and STU

ABOVE-ST3

Between ST3 and ST2

ABOVE-ST3E

Between ST3E and TNC

ABOVE-ST4

Between ST4 and ST3

ABOVE-STU

Between STU and PRS

ABOVE-TNC

Between TNC and PRS

BELOW-ST4

Below ST4 but still usable

SAME-AS-DUS

Disable the RES message by equating it to DUS


11.13.56 TIMING_MODE

Timing mode for the current node

Table 11-75 TIMING_MODE Values

TIMING_MODE Values
Description

EXTERNAL

The node derives its clock from the BITS input

LINE

The node derives its clock from the SONET lines


11.13.57 TMG_REF

Identifies whether or not this entity is the Timing Reference for its group. For equipment, it identifies the facility that is supplying the timing reference. For interface groups, it identifies the card that is supplying the main timing reference.

Table 11-76 TMG_REF Values

TMG_REF Values
Description
N

This facility or card is not a timing reference

Y

This facility or card is a timing reference


11.13.58 TMPR

Performance parameter

Table 11-77 TMPR Values

TMPR Values
Description

15MIN

Performance Parameter Accumulation Interval Length - Every 15 Minutes

1DAY

Performance Parameter Accumulation Interval Length - Every 24 Hours


11.13.59 USE_DST

Identifies whether Daylight Saving Time is recognized in the area where this NE is deployed

Table 11-78 USE_DST Values

USE_DST Values
Description

N

Daylight Saving Time is not recognized

Y

Daylight Saving Time is recognized


11.13.60 VALIDITY

Response validity

Table 11-79 VALIDITY Values

VALIDITY Values
Description

COMPL

Complete Response

PRTL

Partial Response


11.13.61 Performance Monitoring Parameters by Line Type

Table 11-80 Performance Monitoring Parameters by Line Type

 
OC-n
T1
T3
STS
VT1.5

CVL

Y

Y

Y

   

CVP

 

Y

Y

Y

 

CVS

Y

       

CVV

       

Y

ESL

Y

Y

Y

   

ESP

 

Y

Y

Y

 

ESS

Y

       

ESV

       

Y

FCP

     

Y

 

FCL

Y

       

PJNEG

Y

       

PJPOS

Y

       

PSC

Y

       

PSD

Y

       

SASP

 

Y

Y

   

SEFS

Y

       

SESL

Y

Y

Y

   

SESP

 

Y

Y

Y

 

SESS

Y

       

SESV

       

Y

UASL

Y

       

UASP

 

Y

Y

Y

 

UASV

       

Y

AISSP

 

Y

Y

   

CVCPP

   

Y

   

ESCPP

   

Y

   

LOSSL

   

Y

   

SASCPP

   

Y

   

SESCPP

   

Y

   

UASCPP

   

Y

   

11.14 Errors

Errors may be generated by any command or command response message. The format of an error message is as follows:

sid date time
M ctag DENY
<errcde>
/* <errmsg> */
;

Table 11-81 Error Codes 

Error Code
(errcde)
Error Type
Error Message (errmsg)

EANS

EQUIPAGE

Access Not Supported

EATN

EQUIPAGE

Not Valid for Access Type

EFON

EQUIPAGE

Feature Option Not Provided

EN2T

EQUIPAGE

Not 2-Wire Terminate and Leave

ENAC

EQUIPAGE

Not Equipped with Alarm Cutoff

ENAD

EQUIPAGE

Not Equipped with Audit Capability

ENAR

EQUIPAGE

Not Equipped with Automatic Reconfiguration

ENAT

EQUIPAGE

Request Not Valid for Access Type

ENDG

EQUIPAGE

Not Equipped with Diagnostic Capability

ENDS

EQUIPAGE

Not Equipped with Duplex Switching

ENEA

EQUIPAGE

Not Equipped with Error Analysis Capability

ENEQ

EQUIPAGE

Not Equipped

ENEX

EQUIPAGE

Not Equipped with Exercise Capability

ENFE

EQUIPAGE

Feature Not Provided

ENFL

EQUIPAGE

Not Equipped for Fault Locating

ENHN

EQUIPAGE

Not Hybrid Network

ENMB

EQUIPAGE

Not Multipoint Bridge

ENMD

EQUIPAGE

Not Equipped with Memory Device

ENPM

EQUIPAGE

Not Equipped for Performance Monitoring

ENPS

EQUIPAGE

Not Equipped with Protection Switching

ENRE

EQUIPAGE

Not Recognized Equipage

ENRI

EQUIPAGE

Not Equipped for Retrieving Specified Information

ENRS

EQUIPAGE

Not Equipped for Restoration

ENSA

EQUIPAGE

Not Equipped for Scheduling Audit

ENSG

EQUIPAGE

Not Software Generic

ENSI

EQUIPAGE

Not Equipped for Setting Specified Information

ENSS

EQUIPAGE

Not Equipped with Synchronization Switching

ENTL

EQUIPAGE

Not Terminate and Leave

ERLC

EQUIPAGE

Red-Lined Circuit

ERNS

EQUIPAGE

RTU Does Not Support Command

ESPG

EQUIPAGE

Software Program

ETNS

EQUIPAGE

TSC Does Not Support Command

FNCR

FAULT

NE Failure - Circuit Restored to Last Condition - Monitor or Terminate

FNDT

FAULT

No Dial Tone Detected

FNEC

FAULT

NTE Has Lost 8-KHZ Byte Clock

FNSC

FAULT

NTE Has Lost 16-KHZ Byte Clock

FRCE

FAULT

RTU Component or Configuration Error

FRDA

FAULT

RTU Does Not Answer the Call

FREC

FAULT

RTU Eight KHZ Byte Clock Lost

FRNR

FAULT

RTU Does Not Reply

IBEX

INPUT

Block Extra

IBMS

INPUT

Block Missing

IBNC

INPUT

Block Not Consistent

ICNV

INPUT

Command Not Valid

IDMS

INPUT

Data Missing

IDNC

INPUT

Data Not Consistent

IDNV

INPUT

Data Not Valid

IDRG

INPUT

Data Range Error

IIAC

INPUT

Invalid Access Identifier (AID)

IICM

INPUT

Invalid Command

IICT

INPUT

Invalid Correlation Tag

IIDT

INPUT

Invalid Data Parameter

IIFM

INPUT

Invalid Data Format

IIPG

INPUT

Invalid Parameter Grouping

IISP

INPUT

Invalid Syntax or Punctuation

IITA

INPUT

Invalid Target Identifier

INAC

INPUT

Access Number Not Correct

INUP

INPUT

Non-Null Unimplemented Parameter

IPEX

INPUT

Parameter Extra

IPMS

INPUT

Parameter Missing

IPNC

INPUT

Parameter Not Consistent

IPNV

INPUT

Parameter Not Valid

ISCH

INPUT

Syntax Invalid Character

ISPC

INPUT

Syntax Punctuation

ITSN

INPUT

Invalid/Inactive Test Session Number

PICC

PRIVILEGE

Illegal Command Code

PIMA

PRIVILEGE

Invalid Memory Address

PIMF

PRIVILEGE

Invalid Memory File

PIUC

PRIVILEGE

Illegal Privilege Code

PLNA

PRIVILEGE

Login Not Active

RABY

RESOURCE

All Taps Busy

RALB

RESOURCE

All Units of Requested Type are Busy

RANB

RESOURCE

Access Network Busy

RCBY

RESOURCE

Circuit Busy

RCIN

RESOURCE

Requested Circuit ID Does Not Exist

RNAN

RESOURCE

Requested NE Access Number Does Not Exist

RNAU

RESOURCE

Requested NE Access Number Unassigned

RNBY

RESOURCE

NE is Busy

RRCP

RESOURCE

Unit Specified by Routing Code Busy

RRNG

RESOURCE

Requested Changes Exceeds Range

RTBY

RESOURCE

Requested Tap Busy

RTEN

RESOURCE

Requested Tab Does Not Exist

RTUB

RESOURCE

Test Unit Busy

SAAL

STATUS

Already Allowed

SAAS

STATUS

Already Assigned

SABT

STATUS

Aborted

SACS

STATUS

Access Unit Cannot Sync on Facility Signal

SADC

STATUS

Already Disconnected

SADS

STATUS

Access Unit in Diagnostic State

SAIN

STATUS

Already Inhibited

SAIS

STATUS

Already In-Service

SAMS

STATUS

Already in Maintenance State

SAOP

STATUS

Already Operated

SAOS

STATUS

Already Out-of-Service

SAPF

STATUS

Access Path Continuity Check Failed

SAPR

STATUS

Already in Protection State

SARB

STATUS

All Resources Busy

SATF

STATUS

Automatic Test Failed

SCAT

STATUS

Circuit is Already Connected to Another Tap

SCBS

STATUS

Channel Busy

SCIS

STATUS

Circuit in Split Condition

SCNA

STATUS

Command Not Able to be Aborted

SCNF

STATUS

Command Not Found

SCNS

STATUS

Circuit Not in Split Condition

SCOS

STATUS

Channel Out-of-Service

SCSD

STATUS

Can't Split DS0B Circuit

SCSN

STATUS

Invalid Command Sequence

SDAS

STATUS

Diagnosis Already Started

SDBE

STATUS

Internal Data Base Error

SDFA

STATUS

Duplex Unit Failed

SDLD

STATUS

Duplex Unit Locked

SDNA

STATUS

Dumple Unit Not Available

SDNC

STATUS

Input Data is Not Consistent With NE Data

SDNR

STATUS

Data Not Ready

SDNS

STATUS

Diagnosis Not Started Yet

SEOS

STATUS

NTE is Out-of-Service

SFAS

STATUS

Fault Locating Already Started

SFNS

STATUS

Fault Locating Not Started yet

SFYA

STATUS

Facility Reports Yellow Alarm

SLNS

STATUS

Log Not Started Yet

SLOS

STATUS

TSC to RTU Link Out-of-Service

SNCC

STATUS

Not Cross-Connected

SNCN

STATUS

NTE Unable to Execute Command

SNDS

STATUS

NTE is in a Diagnostic State

SNIM

STATUS

NTE Access Complete, Circuit was in Monitor State

SNIS

STATUS

Not in Service

SNML

STATUS

No Monitor Line Established

SNNB

STATUS

NTE Could Not Sync on DS0B Signal

SNNS

STATUS

NTE Could Not Sync on DS-1 Signal

SNOS

STATUS

NTE is Out-of-Service

SNPR

STATUS

Not in Protection State

SNRM

STATUS

System Not in Restoration Mode

SNRS

STATUS

Not Reserved

SNSR

STATUS

No Switch Request Outstanding

SNVS

STATUS

Not in Valid State

SNYA

STATUS

NTE has Detected a Yellow Alarm

SOSE

STATUS

Operating System Error

SOST

STATUS

Out-of-Service, Testing

SPFA

STATUS

Protection Unit Failed

SPLD

STATUS

Protection Unit Locked

SPNA

STATUS

Process Not Able to be Aborted

SPNF

STATUS

Process Not Found

SRAC

STATUS

Requested Access Configuration is Invalid

SRAN

STATUS

Unable to Release Access System

SRCI

STATUS

Requested Command(s) Inhibited

SRCN

STATUS

Requested Condition Already Exists

SROF

STATUS

Requested Operation Failed

SROS

STATUS

Required RTU Out of Service

SRQN

STATUS

Invalid Request

SRTN

STATUS

Unable to Release Tap

SRTO

STATUS

Reply Timeout Occurred

SSCE

STATUS

Systemic (SNIDER) Communications Error

SSNG

STATUS

Subrate Selected is Incorrect

SSNP

STATUS

Speed Selected is Incorrect

SSNQ

STATUS

Test Signal Not QRS

SSRD

STATUS

Switch Request Denied

SSRE

STATUS

System Resources Exceeded

STAB

STATUS

Test Aborted

STLC

STATUS

Tap Unable to Locate Channel

STNO

STATUS

TSC/RTU to TAU Link Out of service

STOS

STATUS

Test Access Unit Out of Service

STTI

STATUS

Tap Idle

SWFA

STATUS

Working Unit Failed

SWLD

STATUS

Working Unit Locked


11.15 Echo

In order to improve telnet functionality for automated systems, the echo function was been turned off in Release 2.1.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.

To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON.


hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Feb 25 07:42:19 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.