Table Of Contents
TL1 Reference
11.1 Overview
11.2 Craft Interface
11.3 TL1 Access using Telnet
11.4 Alarms
11.4.1 Equipment Alarms
11.4.2 OC-N Alarms
11.4.3 DS-3 Alarms
11.4.4 DS-1 Alarms
11.4.5 STS Alarms
11.4.6 VT Termination Alarms
11.4.7 BITS Alarms
11.4.8 Network Element Synch Ref Alarms
11.5 Autonomous Messages
11.6 Performance Monitoring
11.6.1 Performance Monitoring Statistics
11.7 TL1 Command Syntax
11.8 TL1 Command Privilege Map
11.9 TL1 Command List
11.9.1 Cross Connect
11.9.2 Environment
11.9.3 Equipment
11.9.4 Facility
11.9.5 Facility Protection
11.9.6 Fault
11.9.7 Log
11.9.8 Performance
11.9.9 Security
11.9.10 Switch
11.9.11 Synchronization
11.9.12 System
11.9.13 Testing
11.9.14 Other
11.10 TL1 Command Index
11.11 TL1 Command Description
11.11.1 ACT-USER: Activate User
11.11.2 ALW-MSG-ALL: Allow Message All
11.11.3 CANC-USER: Cancel User
11.11.4 DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.5 DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)
11.11.6 DLT-CRS-VT1: Delete Cross Connect Virtual Tributary
11.11.7 DLT-EQPT: Delete Equipment
11.11.8 DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)
11.11.9 DLT-FFP-EQPT: Delete Facilities Protection Equipment
11.11.10 DLT-USER-SECU: Delete User Security
11.11.11 ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)
11.11.12 ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)
11.11.13 ED-BITS: Edit Building Integrated Timing Supply
11.11.14 ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)
11.11.15 ED-CRS-VT1: Edit Cross Connect Virtual Tributary
11.11.16 ED-DAT: Edit Date and Time
11.11.17 ED-EC1: Edit Electrical Carrier Level 1
11.11.18 ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)
11.11.19 ED-FFP-EQPT: Edit Equipment Protection
11.11.20 ED-NE: Edit Network Element
11.11.21 ED-PID: Edit Private Identifier
11.11.22 ED-SYNCN: Edit Synchronization
11.11.23 ED-T1: Edit T1
11.11.24 ED-T3: Edit T3
11.11.25 ED-USER-SECU: Edit User Security
11.11.26 ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.27 ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)
11.11.28 ENT-CRS-VT1: Enter Cross Connect Virtual Tributary
11.11.29 ENT-EQPT: Enter Equipment
11.11.30 ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)
11.11.31 ENT-FFP-EQPT: Enter Equipment Protection
11.11.32 ENT-USER-SECU: Enter User Security
11.11.33 INH-MSG-ALL: Inhibit Message All
11.11.34 INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.35 INIT-SYS: Initialize System
11.11.36 OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)
11.11.37 OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1
11.11.38 OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1
11.11.39 OPR-LPBK-T1: Operate Loopback T1
11.11.40 OPR-LPBK-T3: Operate Loopback T3
11.11.41 OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)
11.11.42 OPR-PROTNSW-EQPT: Operate Protection Switch Equipment
11.11.43 OPR-UPGRADE: Operate Upgrade
11.11.44 REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.45 REPT ALM BITS: Report Alarm Building Integrated Timing Supply
11.11.46 REPT ALM ENV: Report Alarm Environment
11.11.47 REPT ALM EQPT: Report Alarm Equipment
11.11.48 REPT ALM SYNCN: Report Alarm Synchronization
11.11.49 REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.50 REPT EVT EQPT: Report Event Equipment
11.11.51 REPT EVT SYNCN: Report Event Synchronization
11.11.52 RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)
11.11.53 RLS-LPBK-DS1: Release Loopback Digital Signal Level 1
11.11.54 RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1
11.11.55 RLS-LPBK-T1: Release Loopback T1 Facility
11.11.56 RLS-LPBK-T3: Release Loopback T3 Facility
11.11.57 RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)
11.11.58 RLS-PROTNSW-EQPT: Release Protection Switch Equipment
11.11.59 RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.60 RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.61 RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)
11.11.62 RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)
11.11.63 RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)
11.11.64 RTRV-ALM-ALL: Retrieve Alarm All
11.11.65 RTRV-ALM-BITS: Retrieve Alarm Building Integrated Timing Supply
11.11.66 RTRV-ALM-ENV: Retrieve Alarm Environment
11.11.67 RTRV-ALM-EQPT: Retrieve Alarm Equipment
11.11.68 RTRV-ALM-SYNCN: Retrieve Alarm Synchronization
11.11.69 RTRV-BITS: Retrieve Building Integrated Timing Supply
11.11.70 RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.71 RTRV-COND-ALL: Retrieve Condition All
11.11.72 RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply
11.11.73 RTRV-COND-EQPT: Retrieve Condition Equipment
11.11.74 RTRV-COND-SYNCN: Retrieve Condition Synchronization
11.11.75 RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)
11.11.76 RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary
11.11.77 RTRV-EC1: Retrieve Electrical Carrier Level 1
11.11.78 RTRV-EQPT: Retrieve Equipment
11.11.79 RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)
11.11.80 RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment
11.11.81 RTRV-HDR: Retrieve Header
11.11.82 RTRV-INV: Retrieve Inventory
11.11.83 RTRV-LOG: Retrieve Log
11.11.84 RTRV-NE: Retrieve Network Element
11.11.85 RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.86 RTRV-SYNCN: Retrieve SYNCN
11.11.87 RTRV-T1: Retrieve T1
11.11.88 RTRV-T3: Retrieve T3
11.11.89 RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.90 RTRV-TOD: Retrieve Time of Day
11.11.91 SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
11.11.92 SET-TOD: Set Time of Day
11.11.93 SW-DX-EQPT: Switch DX Equipment
11.12 Access Identifiers
11.12.1 bits
11.12.2 ds-1
11.12.3 env
11.12.4 eqpt
11.12.5 facility
11.12.6 sts
11.12.7 syn_src
11.12.8 sync_ref
11.12.9 vt1_5
11.13 Parameter Types
11.13.1 ATAG Description
11.13.2 CTAG Description
11.13.3 TID Description
11.13.4 ALL_MONTYPE
11.13.5 ALL_THR
11.13.6 CCT
11.13.7 COND_EFF
11.13.8 CONDITION
11.13.9 DIRECTION
11.13.10 DS3_FMT
11.13.11 DS_LINE_CODE
11.13.12 DS_LINE_TYPE
11.13.13 DX_MODE_OP
11.13.14 E_LBO
11.13.15 ENV_ALM
11.13.16 ENV_CTL
11.13.17 EQPT_TYPE
11.13.18 EQUIP
11.13.19 EQUIPMENT_TYPE
11.13.20 EXT_RING
11.13.21 FRAME_FORMAT
11.13.22 LINE_BUILDOUT
11.13.23 LINE_CODE
11.13.24 LOCATION
11.13.25 LPBK_TYPE
11.13.26 MOD2
11.13.27 MOD2ALM
11.13.28 MOD2B
11.13.29 MODIFIER
11.13.30 NOTIF_CODE
11.13.31 OCN_MONTYPE
11.13.32 OCN_TYPE
11.13.33 ON_OFF
11.13.34 OPTICAL_MODE
11.13.35 PRIVILEGE
11.13.36 PROT_MOD_OP
11.13.37 PROTECTION_GROUP
11.13.38 PST
11.13.39 REVERTIVE_TIME
11.13.40 REVERTIVE_TYPE
11.13.41 RNG_TYPE
11.13.42 SD_BER
11.13.43 SDCC_MODE
11.13.44 SERV_EFF
11.13.45 SF_BER
11.13.46 SIDE
11.13.47 STATE
11.13.48 STATUS
11.13.49 STM_TYPE
11.13.50 STS_MONTYPE
11.13.51 STS_PATH
11.13.52 SWITCH
11.13.53 SYNC_GENERATION
11.13.54 SYNC_MODE
11.13.55 SYNC_QUALITY_LEVEL
11.13.56 TIMING_MODE
11.13.57 TMG_REF
11.13.58 TMPR
11.13.59 USE_DST
11.13.60 VALIDITY
11.13.61 Performance Monitoring Parameters by Line Type
11.14 Errors
11.15 Echo
11
TL1 Reference
11.1 Overview
This section lists TL1 alarms, commands, and autonomous messages supported by the Cisco ONS 15454. For more information about TL1, refer to Telcordia document GR833-CORE, Network Maintenance: Network Element and Transport Surveillance Messages.
11.2 Craft Interface
The TCC/TCC+ has two built-in interface ports for accessing the ONS 15454. With one RJ-45 craft interface browser LAN connection you can access the system using a standard browser interface. While using the browser interface, you can perform local and remote Operations, Administration, Maintenance and Provisioning (OAM&P) functions and open a VT100 emulation window to enter TL1 commands. If a browser is not available, you can access the system using a nine- pin RS-232 port. The RS-232 port supports VT100 emulation such that TL1 commands may be entered directly without a browser.
Refer to the "Craft Interface Installation" section on page 1-31 for detailed installation procedures. Refer to the "Connecting to the ONS 15454 with TL1 Terminals" section on page 3-9 for information on terminal setup.
11.3 TL1 Access using Telnet
To access the ONS 15454 TL1 commands using a Telnet session over a craft interface or a Local Access Network (LAN) connection (TCC/TCC+ front panel or backplane pins), you must use port number 2361. At a command prompt, start the Telnet session by typing:
telnet <Node IP Address> 2361 [Enter]
11.4 Alarms
This section lists TL1 alarms supported by the ONS 15454. Each alarm list includes a description, service affect criteria, and severity. Refer to Chapter 9, "CTC Alarms," for fault recovery procedures. The following alarm types are listed:
•Equipment Alarms
•SONET Optical Carrier, level n (OC-N) Alarms
•Digital Signal, level 1 (DS-1) Alarms
•Digital Signal, level 3 (DS-3) Alarms
•Synchronous Transport Signal (STS) Alarms
•Virtual Tributary (VT) Termination Alarms
•Building Integrated Timing Supply (BITS) Alarms
•Network Element (NE) Synchronous Reference Alarms
11.4.1 Equipment Alarms
Table 11-1 Equipment Alarms
EQPT alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA (Active/ Standby)
|
Description
|
INT
|
all
any mode
|
CR/MN
|
SA/NSA
|
Internal board Failure
|
IMPROPRMVL
|
all
any mode
|
CR/MN
|
SA/NSA
|
Board is provisioned and has been unplugged
|
MEA
|
all
any mode
|
MN/MN
|
NSA/NSA
|
Mismatch in between the physical equipment type and the provisioned equipment type
|
FAILTOSW- PATH
|
TCC,TCC+,XC,DS-3
any mode
|
MJ/MN
|
SA/NSA
|
Failure to perform an equipment protection switch
|
POWERFAIL
|
all
any mode
|
CR/MN
|
NSA/NSA
|
Power Failure on the node
|
MANUAL
|
TCC,TCC+,XC,DS-3
any mode
|
MN/MN
|
NSA/NSA
|
Operator Manual switch severity active
|
FORCED
|
TCC,TCC+,XC,DS-3
any mode
|
MN/MN
|
NSA/NSA
|
Operator Force switch severity active
|
DIAGFAIL
|
all
any mode
|
CR/MN
|
NSA/NSA
|
Equipment diagnostic failure
|
HITEMP
|
TCC,TCC+
Any mode
|
CR/CR
|
NSA/NSA
|
Excessive temperature - operating still maintaining normal operations
|
FAN
|
all
any mode
|
CR/MI
|
NSA/NSA
|
Fan operation failure
|
PWRRESTART
|
all
any mode
|
MI/MI
|
NSA/NSA
|
Power restart
|
AUTORESET
|
all
any mode
|
MI/MI
|
NSA/NSA
|
Automatic reset
|
MANRESET
|
TCC,TCC+
any mode
|
MI/MI
|
NSA/NSA
|
Manual reset
|
INIT
|
TCC,TCC+
any mod
|
MI/MI
|
NSA/NSA
|
Initialization initiated
|
SWTRANSFER
|
TCC,TCC+
any mod
|
MI/MI
|
NSA/NSA
|
Software download in progress
|
CONTBUS-A-X
|
IO,XC
any mode
|
MJ/MN
|
NSA/NSA
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot X
|
CONTBUS-A-8
|
IO,XC
any mode
|
MJ/MN
|
NSA/NSA
|
Main processor on the TCC/TCC+ card in Slot 7 has lost communication with the coprocessor on the second TCC/TCC+ card in Slot 11
|
CONTBUS-B-X
|
IO,XC
any mode
|
MJ/MN
|
NSA/NSA
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot X
|
CONTBUS-B-8
|
IO,XC
any mode
|
MJ/MN
|
NSA/NSA
|
Main processor on the TCC/TCC+ card in Slot 11 has lost communication with the processor on the second TCC/TCC+ card in Slot 7
|
CTNEQPT-PBXPROT
|
I/O, XC/XCVT
|
CR/MN
|
SA/NSA
|
Failure of the main payload between the XC/XCVT card in Slot 10 and the reporting I/O card in Slot X
|
CTNEQPT-PBXWORK
|
I/O, XC/XCVT
|
CR/MN
|
SA/NSA
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot X
|
11.4.2 OC-N Alarms
Table 11-2 OC-N Alarms
OC-n alarm
|
Card/Mode
|
Severity (Active/
Standby)
|
SA/NSA
(Active/
Standby)
|
Description
|
LOS
|
OC-3, OC-12, OC-48
any mode
|
CR/MN
|
SA/NSA
|
Loss of Signal alarm
|
LOF
|
OC-3,OC-12, OC-48
any mode
|
CR/MN
|
SA/NSA
|
Loss of Frame alarm
|
AIS-L
|
OC-3,OC-12, OC-48
any mode
|
MN/MN
|
SA/NSA
|
Alarm Indication Signal Line alarm
|
RFI-L
|
OC-3,OC-12, OC-48
any mode
|
MN/MN
|
NSA/NSA
|
Remote Failure Indication Line alarm
|
SFBER
|
OC-3,OC-12, OC-48,
any mode
|
CR/MN
|
SA/NSA
|
Signal fail error rate alarm
|
SDBER
|
OC-3,OC-12, OC-48
any mode
|
MN/MN
|
SA/NSA
|
Signal degrade error rate alarm
|
FAILTOSW-RNG
|
OC-3,OC-12, OC-48
2F BLSR mode
|
MJ/MN
|
SA/NSA
|
Failure to perform a two-fiber BLSR ring switch
|
FAILTOSW-SPAN
|
OC-3,OC-12, OC-48
linear mode
|
MJ/MN
|
SA/NSA
|
Failure to perform a Linear APS 1+1 switch
|
MANUAL-REQ
|
OC-3,OC-12, OC-482
2F BLSR mode
|
MN/MN
|
NSA/NSA
|
Manual Ring Switch Severity active
|
FORCED-REQ
|
OC-3,OC-12, OC-48
2F BLSR mode
|
MN/MN
|
SA/NSA
|
Force Ring Switch Severity active
|
LOCKOUTOFPR- RING
|
OC-3,OC-12, OC-482
2F BLSR mode
|
MN/MN
|
SA/NSA
|
Lockout of Protection Channel Switch Severity active
|
MANUAL-SPAN
|
OC-3,OC-12, OC-48
linear mode
|
MN/MN
|
NSA/NSA
|
Manual Span Switch Severity active
|
FORCED-SPAN
|
OC-3,OC-12, OC-482
linear mode
|
MN/MN
|
SA/NSA
|
Force Span switch Severity active
|
LOCKOUT-SPAN
|
OC-3,OC-12, OC-48
linear mode
|
MN/MN
|
SA/NSA
|
Lockout Span Switch Severity active
|
APSB
|
OC-3,OC-12, OC-48
linear mode
|
MJ/MN
|
SA/NSA
|
Automatic Protection Switching (APS) byte failure
|
APSCM
|
OC-3,OC-12, OC-48
linear mode
|
MJ/MN
|
SA/NSA
|
APS Channel Mismatch failure
|
APSMM
|
OC-3,OC-12, OC-48
linear mode
|
MJ/MN
|
SA/NSA
|
APS Mode Mismatch failure
|
APSFERPFAIL
|
|
MN/MN
|
NSA/NSA
|
APS channel far-end protection line failure
|
EOC
|
|
MJ/MN
|
NSA/NSA
|
Data communication channel failure
|
SQUELCH
|
OC-12,OC-48
2F BLSR mode
|
MJ/MN
|
SA/NSA
|
Squelching in progress
|
INCON
|
OC-12,OC-48
2F BLSR mode
|
MJ/MN
|
SA/NSA
|
Inconsistent APS code
|
APSCIMP
|
OC-12,OC-48
2F BLSR mode
|
MJ/MN
|
SA/NSA
|
Improper SONET Automatic Protect Switch code
|
NODEMIS
|
OC-12,OC-48
2F BLSR mode
|
MJ/MN
|
SA/NSA
|
Node Id mismatch failure
|
DFLTK
|
OC-12,OC-48
2F BLSR mode
|
MN/MN
|
NSA/NSA
|
Default K byte transmitted
|
CONNLOS
|
TCC/TCC+
2F BLSR mode
|
MJ/MN
|
NSA/NSA
|
Inter-node connectivity lost in two-fiber BLSR configuration
|
ALS
|
|
CR/MN
|
NSA/NSA
|
Automatic laser shut down
|
LPBKTERMIN
|
OC-3,OC-12, OC-48
any mode
|
MJ/MI
|
SA/NSA
|
Terminal loopback active
|
LPBKFACILITY
|
OC-3, OC-12, OC-48
any mode
|
MJ/MI
|
SA/NSA
|
Facility loopback active
|
11.4.3 DS-3 Alarms
Table 11-3 DS-3 Alarms
DS-3 alarm
|
Card/Mode
|
Severity (Active)
|
SA/NSA (Active)
|
Description
|
PEERMISSM
|
DS-3
any mode
|
MJ
|
SA
|
Peer state mismatch
|
LOS
|
DS-3
any mode
|
CR
|
SA
|
Loss of signal alarm
|
LPBK
|
DS-3
any mode
|
MJ
|
SA
|
Loopback active
|
IDLE
|
DS-3
any mode
|
MJ
|
SA
|
DS-3 idle condition
|
RAI
|
DS-3
any mode
|
MN
|
SA
|
Remote alarm indication
|
DS3MANTERM- LPBK
|
DS-3
any mode
|
MJ
|
SA
|
Loopback terminal
|
DS3MANFAC LPBK
|
DS-3
any mode
|
MJ
|
SA
|
Loopback facility
|
DS3FELPBK
|
DS-3
any mode
|
MJ
|
SA
|
Loopback due to Far-End Alarm Condition (FEAC) command
|
DS2FELPBK
|
DS-3
any mode
|
MJ
|
SA
|
DS-2 loopback command sent to far-end
|
DS1FELPBK
|
DS-3
any mode
|
MJ
|
SA
|
DS- 1 loopback due to FEAC command
|
DS3FELPBK
|
DS-3
any mode
|
MJ
|
SA
|
DS-3 loopback due to FEAC command
|
DS3FELPBKCMD
|
DS-3
any mode
|
MJ
|
SA
|
DS-3 loopback command sent to far-end
|
FE-EQPT-FAIL-SA
|
DS-3
any mode
|
MJ
|
SA
|
Far-end DS-3 equipment fail service-affecting
|
FE-LOS
|
DS-3
any mode
|
MJ
|
SA
|
Far-end loss of signal
|
FE-LOF
|
DS-3
any mode
|
MJ
|
SA
|
Far-end loss of frame
|
FE-AIS
|
DS-3
any mode
|
MJ
|
SA
|
Far-end alarm indication signal
|
FE-IDLE
|
DS-3
any mode
|
MJ
|
SA
|
Far-end idle
|
FE-EQPT-NSA
|
DS-3
any mode
|
MJ
|
SA
|
Far-end DS-3 equipment fail non-service affecting
|
DS3FECMNEQPT
FAIL
|
DS-3
any mode
|
MJ
|
SA
|
Far-end common equipment fail non-service affecting
|
FE-DS1-MULTI LOS
|
DS3XM
any mode
|
MJ
|
SA
|
Far-end multiple DS-1 LOS detected on DS-3
|
DS1FEEQPTFAIL SA
|
DS3XM
any mode
|
MJ
|
SA
|
Far-end DS-1 equipment fail service-affecting
|
FE-SD1-SNGLLOS
|
DS3XM
any mode
|
MJ
|
SA
|
DS-1 far-end single DS-1 LOS
|
DS1FEEQPT
|
DS3XM
any mode
|
MJ
|
SA
|
Far-end DS-1 equipment failure service-affecting
|
11.4.4 DS-1 Alarms
Table 11-4 DS-1 Alarms
DS-1 alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA (Active/ Standby)
|
Description
|
LOS
|
DS-1
any mode
|
MJ/None
|
SA/None
|
Loss of signal alarm
|
AIS
|
DS-1
any mode
|
MJ/None
|
SA/None
|
Alarm indication signal alarm
|
LOF
|
DS-1
any mode
|
MJ/None
|
SA/None
|
Loss of frame alarm
|
RAI
|
DS-1
any mode
|
MN/None
|
SA/None
|
Remote alarm indication alarm
|
TERMLPBK
|
DS-1
any mode
|
MJ/None
|
SA/None
|
Terminal loopback active
|
FACLPBK
|
DS-1
any mode
|
MJ/None
|
SA/None
|
Facility loopback active
|
ELECTRICAL INTERFACE MISSING - TX
|
DS-1
any mode
|
MJ/MN
|
NSA/NSA
|
Facility Termination equipment - Transmitter missing
|
ELECTRICAL INTERFACE MISSING - RX
|
DS-1
any mode
|
MJ/MN
|
NSA/NSA
|
Facility Termination equipment - Receiver missing
|
ELECTRICAL INTERFACE FAILURE - TX
|
DS-1
any mode
|
MJ/MN
|
NSA/NSA
|
Transmit Failure
|
FELPBK
|
DS-1
any mode
|
MJ/None
|
SA/None
|
DS-1 loopback due to FEAC command
|
FELPBKCMD
|
DS-1
any mode
|
MJ/None
|
SA/None
|
DS-1 loopback command sent to far-end
|
11.4.5 STS Alarms
Table 11-5 STS Alarms
STS Mon alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA (Active/ Standby)
|
Description
|
AIS-P
|
STS Monitor
any mode
|
MJ/MN
|
SA/NSA
|
Alarm Indication Signal alarm
|
LOP
|
STS Monitor
any mode
|
MJ/MN
|
SA/NSA
|
Loss of Pointer alarm
|
CONCAT
|
STS Monitor
any mode
|
MJ/MN
|
SA/NSA
|
STS concatenation alarm
|
UNEQ-P
|
STS Termination on DS-3 card any mode
|
MJ/MN
|
SA/NSA
|
Path Unequipped alarm
|
SFBER
|
STS Termination on DS-3 card
any mode
|
MJ/MN
|
SA/NSA
|
Path Signal Fail bit error rate alarm
|
SDBER
|
STS Termination on DS-3 card
any mode
|
MN/MN
|
SA/NSA
|
Path Signal Degrade bit error rate alarm
|
RFI
|
STS Termination on DS-3 card
any mode
|
MN/MN
|
SA/NSA
|
Path Remote Failure Indication alarm
|
SLMF
|
STS Termination on DS-3 card
any mode
|
MN/MN
|
SA/NSA
|
Signal Label Mismatch alarm
|
PDI-P
|
|
MN/MN
|
SA/NSA
|
Payload Defect Indication Path
|
PLM-P
|
|
MN/MN
|
SA/NSA
|
Payload Label Mismatch Path
|
FAILTOSW
|
STS Termination on DS-3 card
any mode
|
MJ/MN
|
NSA/NSA
|
Fail to switch to protection
|
MANUAL
|
STS Termination on DS-3 card
any mode
|
MN/MN
|
NSA/NSA
|
Manual switch of working facility equipment to protection
|
FORCED
|
STS Termination on DS-3 card
any mode
|
MN/MN
|
NSA/NSA
|
Working facility/equipment forced to switch to protection
|
11.4.6 VT Termination Alarms
Table 11-6 VT Termination Alarms
VT Term alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA (Active/ Standby)
|
Description
|
LOP
|
STS Monitor any mode
|
MJ/MN
|
SA/NSA
|
Loss of pointer alarm
|
AIS
|
VT Termination on DS-1 card any mode
|
MJ/MN
|
SA/NSA
|
VT Alarm Indication Signal alarm
|
UNEQP
|
VT Termination on DS-1 card any mode
|
MJ/MN
|
SA/NSA
|
VT Unequipped alarm
|
RFI
|
VT Termination on DS-1 card any mode
|
MN/MN
|
SA/NSA
|
VT Remote Failure Indication alarm
|
PLM
|
VT Termination on DS-1 card any mode
|
MN/MN
|
SA/NSA
|
VT Payload Label Mismatch alarm
|
SFBER
|
|
MJ/MN
|
SA/NSA
|
BER threshold passed for signal failure
|
SDBER
|
|
MJ/MN
|
SA/NSA
|
BER threshold passed for signal degrade
|
11.4.7 BITS Alarms
Table 11-7 Bits Alarms
BITS alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA (Active/ Standby)
|
Description
|
LOS
|
Bits on
TCC/TCC+ card any mode
|
MJ/MN
|
SA/NSA
|
Loss of Signal alarm
|
LOF
|
Bits on
TCC/TCC+ card any mode
|
MJ/MN
|
SA/NSA
|
Loss of Frame alarm
|
AIS
|
Bits on
TCC/TCC+ card any mode
|
MJ/MN
|
SA/NSA
|
Alarm Indication Signal alarm
|
11.4.8 Network Element Synch Ref Alarms
Table 11-8 Synch Ref Alarms
neSynchRef alarm
|
Card/Mode
|
Severity (Active/ Standby)
|
SA/NSA
|
Description
|
SYNCPRI
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Primary Synchronization reference failure alarm
|
SYNCSEC
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Secondary Synchronization reference failure alarm
|
SYNCTHIRD
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Third Synchronization reference failure alarm
|
HLDOVRSYNC
|
neSynchRef on
TCC/TCC+ card any mode
|
MJ/MN
|
SA/NSA
|
Holdover Synchronization alarm
|
FRNGSYNC
|
neSynchRef on
TCC/TCC+ card any mode
|
MJ/MN
|
SA/NSA
|
Free Run Synchronization alarm
|
MANUAL
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Operator-initiated synchronization switch
|
FASTSTART
|
Fast start
Synch node
|
No
|
No Alarm
|
Fast Start Synchronization alarm
|
MANSWTOPRI
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to primary reference
|
MANSWTOSEC
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to second reference
|
MANSWTOTHID
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to third reference
|
SWTOPRI
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to primary reference
|
SWTOSEC
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to second reference
|
SWTOTHIRD
|
neSynchRef on
TCC/TCC+ card any mode
|
MN/MN
|
NSA/NSA
|
Synchronization switch to third reference
|
11.5 Autonomous Messages
The autonomous TL1 messages are included in the TL1 Command Description section, and the messages are listed alphabetically. Figure 11-1 shows the autonomous alarm message format. Autonomous Message Tag (ATAG) is used for message sequencing. The number is incremented by one for each autonomous message sent by the ONS 15454. The ONS 15454 uses whole numbers 0000 to 9999.
Figure 11-1 Autonomous Alarm Message Format
11.6 Performance Monitoring
Performance information is continuously monitored and stored in individual Performance Monitoring (PM) registers. This information can be retrieved upon request or when a preset threshold is exceeded. lists PM Statistics by board.
11.6.1 Performance Monitoring Statistics
Table 11-9 PM Statistics
PM Statistics by Board
|
Special Qualifications
|
Source
|
DS-1
|
DS-3
|
DS-3 XM
|
OC-3/12/48
|
EC-1
|
Sonet Section Stats
|
|
|
|
|
|
|
|
CV-S
|
(not supported yet)
|
B1
|
|
|
|
|
|
ES-S
|
(not supported yet)
|
B1
|
|
|
|
|
|
SES-S
|
(not supported yet)
|
B1
|
|
|
|
|
|
SEFS-S
|
|
B1
|
|
|
|
X
|
X
|
Sonet Line Stats
|
|
|
|
|
|
|
|
CV-L
|
|
B2
|
|
|
|
X
|
X
|
ES-L
|
|
B2
|
|
|
|
X
|
X
|
SES-L
|
|
|
|
|
|
X
|
X
|
UAS-L
|
|
|
|
|
|
X
|
X
|
FC-L
|
|
|
|
|
|
X
|
X
|
PSC
|
|
|
|
|
|
X
|
|
PSD
|
|
|
|
|
|
X
|
|
STS PJ
|
Non-terminated STS only
|
H1, H2
|
|
|
|
|
|
PPJC-PDET
|
Positive detected at input
|
|
|
|
|
X
|
X
|
NPJC-PDET
|
Negative detected at input
|
|
|
|
|
X
|
X
|
PPJC-PGEN
|
Positive generated
|
|
|
|
|
X
|
X
|
NPJC-PGEN
|
Negative generated
|
|
|
|
|
X
|
X
|
Far End
|
|
|
|
|
|
|
|
CV-L FE
|
|
K2
|
|
|
|
X
|
X
|
ES-L FE
|
|
K2
|
|
|
|
X
|
X
|
SES-L FE
|
|
K2
|
|
|
|
X
|
X
|
UAS-L FE
|
|
K2
|
|
|
|
X
|
X
|
FC-L FE
|
|
K2
|
|
|
|
X
|
X
|
Sonet Path Stats
|
|
|
|
|
|
|
|
CV-P
|
|
B3
|
X
|
X
|
X
|
|
|
ES-P
|
|
|
X
|
X
|
X
|
|
|
SES-P
|
|
|
X
|
X
|
X
|
|
|
UAS-P
|
|
|
X
|
X
|
X
|
|
|
FC-P
|
|
|
|
|
|
|
|
VT PJ
|
|
|
|
|
|
|
|
Far End
|
Supplied by XCON
|
|
|
|
|
|
|
CV-P FE
|
From XCON
|
|
|
|
|
X
|
|
ES-P FE
|
From XCON
|
|
|
|
|
X
|
|
SES-P FE
|
From XCON
|
|
|
|
|
X
|
|
UAS-P FE
|
From XCON
|
|
|
|
|
X
|
|
FC-P FE
|
|
|
|
|
|
|
|
VT Path Stats
|
VT terminated circuits only
|
|
|
|
|
|
|
CV-V
|
|
|
X
|
|
X
|
|
|
ES-V
|
|
|
X
|
|
X
|
|
|
SES-V
|
|
|
X
|
|
X
|
|
|
UAS-V
|
|
|
X
|
|
X
|
|
|
FC-V
|
|
|
|
|
|
|
|
Far End
|
|
|
|
|
|
|
|
CV-V FE
|
|
|
X
|
|
X
|
|
|
ES-V FE
|
|
|
X
|
|
X
|
|
|
SES-V FE
|
|
|
X
|
|
X
|
|
|
UAS-V FE
|
|
|
X
|
|
X
|
|
|
FC-V FE
|
|
|
|
|
|
|
|
DS-n Stats
|
|
|
|
|
|
|
|
DS-n Line
|
|
|
|
|
|
|
|
CV-L
|
|
X
|
X
|
X
|
X
|
|
|
ES-L
|
|
X
|
X
|
X
|
X
|
|
|
LOSS-L
|
|
|
|
|
X
|
|
|
SES-L
|
|
X
|
X
|
X
|
X
|
|
|
DS-3 Path
|
|
|
|
|
|
|
|
P Bit Stats
|
M13 & C Bit Framing
|
|
|
|
|
|
|
AISS-P
|
|
|
|
|
X
|
|
|
CVP-0
|
|
|
|
|
X
|
|
|
ESP-P
|
|
|
|
|
X
|
|
|
SASP-P
|
|
|
|
|
X
|
|
|
SESP-P
|
|
|
|
|
X
|
|
|
UASP-P
|
|
|
|
|
X
|
|
|
CP Bit Stats
|
C Bit Framing ONLY
|
|
|
|
|
|
|
CVCP-P
|
|
|
|
|
X
|
|
|
ESCP-P
|
|
|
|
|
X
|
|
|
SASCP-P
|
|
|
|
|
X
|
|
|
SESCP-P
|
|
|
|
|
X
|
|
|
UASCP-P
|
|
|
|
|
X
|
|
|
Far End
|
|
|
|
|
|
|
|
CVCP-P FE
|
|
|
|
|
X
|
|
|
ESCP-P FE
|
|
|
|
|
X
|
|
|
SASCP-P FE
|
|
|
|
|
X
|
|
|
SESCP-P FE
|
|
|
|
|
X
|
|
|
UASCP-P FE
|
|
|
|
|
X
|
|
|
DS-1 Path
|
|
|
|
|
|
|
|
CV-P RX
|
|
|
X
|
|
|
|
|
AISS-P RX
|
|
|
X
|
|
X
|
|
|
ES-P RX
|
|
|
X
|
|
X
|
|
|
SAS-P RX
|
|
|
X
|
|
X
|
|
|
SES-P RX
|
|
|
X
|
|
X
|
|
|
UAS-P RX
|
|
|
X
|
|
X
|
|
|
CV-P TX
|
|
|
X
|
|
X
|
|
|
AISS-P TX
|
|
|
X
|
|
X
|
|
|
ES-P TX
|
|
|
X
|
|
X
|
|
|
SAS-P TX
|
|
|
X
|
|
X
|
|
|
SES-P TX
|
|
|
X
|
|
X
|
|
|
UAS-P TX
|
|
|
X
|
|
X
|
|
|
11.7 TL1 Command Syntax
TL1 commands conform to the following syntax:
a:b:c::d:e: ... z;
where:
"a" is the Command Code
"b" is the Target Identifier (TID)
"c" is the Access Identifier (AID) or the User Identifier (UID)
"d" is the Correlation Tag (CTAG)
"e: ... z;" are the other positions required for various commands
The TID, AID, and CTAG route and control the TL1 command. Other parameters provide additional messages required to complete the action requested by the command.
The TID is a unique name given to each system when it is installed. The name identifies the particular NE (in this case, the ONS 15454), to which each command is directed. Each TID can have a maximum of 20 alpha-numeric characters. To establish the TID for a ONS 15454 node, use the Network Element Name option of the Network Element Configuration menu.
The AID is an access code used to identify and address specific objects within the ONS 15454. These objects include individual pieces of equipment, transport spans, access tributaries, and other objects.
The CTAG is a unique identifier given to each input command by the operator. When the ONS 15454 system responds to a specific command, it includes the command's CTAG in the reply. This eliminates discrepancies about what response corresponds to what command. Valid CTAG values include strings of up to six characters comprised of identifiers (alphanumeric, beginning with a letter) or decimal numerals (a string of decimal digits with an optional non-trailing ".").
11.8 TL1 Command Privilege Map
The following table specifies command access privileges.
Table 11-10 Command Access
Command
|
Superuser
|
Provision
|
Maintenance
|
Retrieve
|
DLT-USER-SECU
|
X
|
|
|
|
ED-DAT
|
X
|
|
|
|
ED-USER-SECU
|
X
|
|
|
|
ENT-USER-SECU
|
X
|
|
|
|
SET-TOD
|
X
|
X
|
|
|
DLT-*-*
|
X
|
X
|
|
|
ED-*-*
|
X
|
X
|
|
|
ENT-*-*
|
X
|
X
|
|
|
SET-*-*
|
X
|
X
|
|
|
INIT-*-*
|
X
|
X
|
X
|
|
OPR-*-*
|
X
|
X
|
X
|
|
RLS-*-*
|
X
|
X
|
X
|
|
RMV-*-*
|
X
|
X
|
X
|
|
RST-*-*
|
X
|
X
|
X
|
|
SW-*-*
|
X
|
X
|
X
|
|
ALW-*-*
|
X
|
X
|
X
|
X
|
INH-*-*
|
X
|
X
|
X
|
X
|
REPT * *
|
X
|
X
|
X
|
X
|
RTRV-*-*
|
X
|
X
|
X
|
X
|
CANC-*-*
|
X
|
X
|
X
|
X
|
ACT-*-*
|
X
|
X
|
X
|
X
|
ED-PD
|
X
|
X
|
X
|
X
|
User security levels also limit the amount of time a user can leave the system idle before the TL1 session is locked to prevent unauthorized users from making changes. Higher security levels have shorter idle times. shows security levels and their idle times
Table 11-11 Security Idle Times
Security Level
|
Idle Time
|
Retrieve
|
Unlimited
|
Maintenance
|
60 minutes
|
Provision
|
30 minutes
|
Superuser
|
15 minutes
|
11.9 TL1 Command List
11.9.1 Cross Connect
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
11.9.2 Environment
REPT ALM ENV
RTRV-ALM-ENV
11.9.3 Equipment
DLT-EQPT
DLT-FFP-EQPT
ED-FFP-EQPT
ENT-EQPT
ENT-FFP-EQPT
OPR-PROTNSW-EQPT
REPT ALM EQPT
REPT EVT EQPT
RLS-PROTNSW-EQPT
RTRV-ALM-EQPT
RTRV-COND-EQPT
RTRV-EQPT
RTRV-FFP-EQPT
SW-DX-EQPT
11.9.4 Facility
RMV-<MOD2>
RST-<MOD2>
11.9.5 Facility Protection
DLT-FFP-<OCN_TYPE>
ED-FFP-<OCN_TYPE>
ENT-FFP-<OCN_TYPE>
RTRV-FFP-<OCN_TYPE>
11.9.6 Fault
REPT ALM <MOD2ALM>
REPT ALM BITS
REPT EVT <MOD2ALM>
RTRV-ALM-<MOD2ALM>
RTRV-ALM-ALL
RTRV-ALM-BITS
RTRV-COND-<MOD2ALM>
RTRV-COND-ALL
RTRV-COND-BITS
11.9.7 Log
RTRV-LOG
11.9.8 Performance
INIT-REG-<MOD2>
RTRV-PM-<MOD2>
RTRV-TH-<MOD2>
SET-TH-<MOD2>
11.9.9 Security
DLT-USER-SECU
ED-PID
ED-USER-SECU
ENT-USER-SECU
11.9.10 Switch
OPR-PROTNSW-<OCN_TYPE>
RLS-PROTNSW-<OCN_TYPE>
11.9.11 Synchronization
ED-SYNCN
REPT ALM SYNCN
REPT EVT SYNCN
RTRV-ALM-SYNCN
RTRV-COND-SYNCN
RTRV-SYNCN
11.9.12 System
ACT-USER
ALW-MSG-ALL
CANC-USER
ED-DAT
INH-MSG-ALL
INIT-SYS
RTRV-HDR
11.9.13 Testing
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
11.9.14 Other
DLT-<MODE2>
ED-<OCN_TYPE>
ED-<STS_PATH>
ED-BITS
ED-EC1
ED-NE
ED-T1
ED-T3
ENT-<MOD2>
OPR-UPGRADE
RTRV-<OCN_TYPE>
RTRV-<STS_PATH>
RTRV-BITS
RTRV-EC1
RTRV-INV
RTRV-NE
RTRV-T1
RTRV-T3
RTRV-TOD
SET-TOD
11.10 TL1 Command Index
Table 11-12 Command Index
Command
|
Group
|
Page Number
|
ACT-USER
|
System
|
ACT-USER: Activate User
|
ALW-MSG-ALL
|
System
|
ALW-MSG-ALL: Allow Message All
|
CANC-USER
|
System
|
CANC-USER: Cancel User
|
DLT-<MODE2>
|
Other
|
DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
DLT-CRS-<STS_PATH>
|
Cross Connect
|
DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)
|
DLT-CRS-VT1
|
Cross Connect
|
DLT-CRS-VT1: Delete Cross Connect Virtual Tributary
|
DLT-EQPT
|
Equipment
|
DLT-EQPT: Delete Equipment
|
DLT-FFP-<OCN_TYPE>
|
Facility Protection
|
DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)
|
DLT-FFP-EQPT
|
Equipment
|
DLT-FFP-EQPT: Delete Facilities Protection Equipment
|
DLT-USER-SECU
|
Security
|
DLT-USER-SECU: Delete User Security
|
ED-<OCN_TYPE>
|
Other
|
ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)
|
ED-<STS_PATH>
|
Other
|
ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)
|
ED-BITS
|
Other
|
ED-BITS: Edit Building Integrated Timing Supply
|
ED-CRS-<STS_PATH>
|
Cross Connect
|
ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)
|
ED-CRS-VT1
|
Cross Connect
|
ED-CRS-VT1: Edit Cross Connect Virtual Tributary
|
ED-DAT
|
System
|
ED-DAT: Edit Date and Time
|
ED-EC1
|
Other
|
ED-EC1: Edit Electrical Carrier Level 1
|
ED-FFP-<OCN_TYPE>
|
Facility Protection
|
ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)
|
ED-FFP-EQPT
|
Equipment
|
ED-FFP-EQPT: Edit Equipment Protection
|
ED-NE
|
Other
|
ED-NE: Edit Network Element
|
ED-PID
|
Security
|
ED-PID: Edit Private Identifier
|
ED-SYNCN
|
Synchronization
|
ED-SYNCN: Edit Synchronization
|
ED-T1
|
Other
|
ED-T1: Edit T1
|
ED-T3
|
Other
|
ED-T3: Edit T3
|
ED-USER-SECU
|
Security
|
ED-USER-SECU: Edit User Security
|
ENT-<MOD2>
|
Other
|
ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
ENT-CRS-<STS_PATH>
|
Other
|
ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)
|
ENT-CRS-VT1
|
Other
|
ENT-CRS-VT1: Enter Cross Connect Virtual Tributary
|
ENT-EQPT
|
Equipment
|
ENT-EQPT: Enter Equipment
|
ENT-FFP-<OCN_TYPE>
|
Facility Protection
|
ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)
|
ENT-FFP-EQPT
|
Equipment
|
ENT-FFP-EQPT: Enter Equipment Protection
|
ENT-USER-SECU
|
Security
|
ENT-USER-SECU: Enter User Security
|
INH-MSG-ALL
|
System
|
INH-MSG-ALL: Inhibit Message All
|
INIT-REG-<MOD2>
|
Performance
|
INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
INIT-SYS
|
System
|
INIT-SYS: Initialize System
|
OPR-LPBK-<OCN_TYPE>
|
Testing
|
OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)
|
OPR-LPBK-DS1
|
Testing
|
OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1
|
OPR-LPBK-EC1
|
Testing
|
OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1
|
OPR-LPBK-T1
|
Testing
|
OPR-LPBK-T1: Operate Loopback T1
|
OPR-LPBK-T3
|
Testing
|
OPR-LPBK-T3: Operate Loopback T3
|
OPR-PROTNSW-<OCN_TYPE>
|
Switch
|
OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)
|
OPR-PROTNSW-EQPT
|
Equipment
|
OPR-PROTNSW-EQPT: Operate Protection Switch Equipment
|
OPR-UPGRADE
|
Other
|
OPR-UPGRADE: Operate Upgrade
|
REPT ALM <MOD2ALM>
|
Fault
|
REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
REPT ALM BITS
|
Fault
|
REPT ALM BITS: Report Alarm Building Integrated Timing Supply
|
REPT ALM ENV
|
Environment
|
REPT ALM ENV: Report Alarm Environment
|
REPT ALM EQPT
|
Equipment
|
REPT ALM EQPT: Report Alarm Equipment
|
REPT ALM SYNCN
|
Synchronization
|
REPT ALM SYNCN: Report Alarm Synchronization
|
REPT EVT <MOD2ALM>
|
Fault
|
REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
REPT EVT EQPT
|
Equipment
|
REPT EVT EQPT: Report Event Equipment
|
REPT EVT SYNCN
|
Synchronization
|
REPT EVT SYNCN: Report Event Synchronization
|
RLS-LPBK-<OCN_TYPE>
|
Testing
|
RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)
|
RLS-LPBK-DS1
|
Testing
|
RLS-LPBK-DS1: Release Loopback Digital Signal Level 1
|
RLS-LPBK-EC1
|
Testing
|
RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1
|
RLS-LPBK-T1
|
Testing
|
RLS-LPBK-T1: Release Loopback T1 Facility
|
RLS-LPBK-T3
|
Testing
|
RLS-LPBK-T3: Release Loopback T3 Facility
|
RLS-PROTNSW-<OCN_TYPE>
|
Switch
|
RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)
|
RLS-PROTNSW-EQPT
|
Equipment
|
RLS-PROTNSW-EQPT: Release Protection Switch Equipment
|
RMV-<MOD2>
|
Facility
|
RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
RST-<MOD2>
|
Facility
|
RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
RTRV-<OCN_TYPE>
|
Other
|
RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)
|
RTRV-<STS_PATH>
|
Other
|
RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)
|
RTRV-ALM-<MOD2ALM>
|
Fault
|
RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)
|
RTRV-ALM-ALL
|
Fault
|
RTRV-ALM-ALL: Retrieve Alarm All
|
RTRV-ALM-BITS
|
Fault
|
RTRV-BITS: Retrieve Building Integrated Timing Supply
|
RTRV-ALM-ENV
|
Environment
|
RTRV-ALM-ENV: Retrieve Alarm Environment
|
RTRV-ALM-EQPT
|
Equipment
|
RTRV-ALM-EQPT: Retrieve Alarm Equipment
|
RTRV-ALM-SYNCN
|
Synchronization
|
RTRV-ALM-SYNCN: Retrieve Alarm Synchronization
|
RTRV-BITS
|
Other
|
RTRV-BITS: Retrieve Building Integrated Timing Supply
|
RTRV-COND-<MOD2ALM>
|
Fault
|
RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
RTRV-COND-ALL
|
Fault
|
RTRV-COND-ALL: Retrieve Condition All
|
RTRV-COND-BITS
|
Fault
|
RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply
|
RTRV-COND-EQPT
|
Equipment
|
RTRV-COND-EQPT: Retrieve Condition Equipment
|
RTRV-COND-SYNCN
|
Synchronization
|
RTRV-COND-SYNCN: Retrieve Condition Synchronization
|
RTRV-CRS-<STS_PATH>
|
Cross Connect
|
RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)
|
RTRV-CRS-VT1
|
Cross Connect
|
RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary
|
RTRV-EC1
|
Other
|
RTRV-EC1: Retrieve Electrical Carrier Level 1
|
RTRV-EQPT
|
Equipment
|
RTRV-EQPT: Retrieve Equipment
|
RTRV-FFP-<OCN_TYPE>
|
Facility Protection
|
RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)
|
RTRV-FFP-EQPT
|
Equipment
|
RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment
|
RTRV-HDR
|
System
|
RTRV-HDR: Retrieve Header
|
RTRV-INV
|
Other
|
RTRV-INV: Retrieve Inventory
|
RTRV-LOG
|
Log
|
RTRV-LOG: Retrieve Log
|
RTRV-NE
|
Other
|
RTRV-NE: Retrieve Network Element
|
RTRV-PM-<MOD2>
|
Performance
|
RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
RTRV-SYNCN
|
Synchronization
|
RTRV-SYNCN: Retrieve SYNCN
|
RTRV-T1
|
Other
|
RTRV-T1: Retrieve T1
|
RTRV-T3
|
Other
|
RTRV-T3: Retrieve T3
|
RTRV-TH-<MOD2>
|
Performance
|
RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
RTRV-TOD
|
Other
|
RTRV-TOD: Retrieve Time of Day
|
SET-TH-<MOD2>
|
Performance
|
SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
|
SET-TOD
|
Other
|
SET-TOD: Set Time of Day
|
SW-DX-EQPT
|
Equipment
|
SW-DX-EQPT: Switch DX Equipment
|
11.11 TL1 Command Description
This section lists TL1 commands supported by the ONS 15454. Each listing includes a description, input format, input parameters (instructions within a command), and input example. The descriptions are alphabetical according to the first alpha character of the command string.
Note The TL1 input command string size should equal and less than 1023 characters from either a TL1 telnet session or CTC. Any TL1 input string larger than 1023 characters will cause the active TCC to reset.
Note TL1 commands not entered correctly are not completed.
11.11.1 ACT-USER: Activate User
This command allows you to log in to the Network Element (NE).
Section
|
Description
|
Category
|
System
|
Security
|
Read Only
|
Related Messages
|
ALW-MSG-ALL
CANC-USER
DLT-USER-SECU
ED-DAT
ED-PID
ED-USER-SECU
ENT-USER-SECU
INH-MSG-ALL
INIT-SYS
RTRV-HDR
|
Input Format
|
ACT-USER:[TID]:<userid>:[CTAG]::<passwd>;
where:
•userid identifies the user to the system and is a String
•passwd is the user's private password and is a String
|
Example
|
Input
ACT-USER:PETALUMA:TERRI:100::MYPASSWD;
|
Errors
|
This message generates all the default errors
|
11.11.2 ALW-MSG-ALL: Allow Message All
This command instructs the NE to enter a mode in which all automatic messages are transmitted.
Section
|
Description
|
Category
|
System
|
Security
|
N/A
|
Related Messages
|
ACT-USER
CANC-USER
ED-DAT
INH-MSG-ALL
INIT-SYS
RTRV-HDR
|
Input Format
|
ALW-MSG-ALL:[TID]::[CTAG]::,,;
|
Example
|
Input
ALW-MSG-ALL:PETALUMA::549::,,;
|
Errors
|
This message generates all the default errors
|
11.11.3 CANC-USER: Cancel User
This command logs a user off of the NE.
Section
|
Description
|
Category
|
System
|
Security
|
Read Only
|
Related Messages
|
ACT-USER
ALW-MSG-ALL
DLT-USER-SECU
ED-DAT
ED-PID
ED-USER-SECU
ENT-USER-SECU
INH-MSG-ALL
INIT-SYS
RTRV-HDR
|
Input Format
|
CANC-USER:[TID]:[<userid>]:[CTAG];
where:
•userid identifies the user to the system and is a String
|
Example
|
Input
CANC-USER:PETALUMA:TERRI:101;
|
Errors
|
This message generates all the default errors
|
11.11.4 DLT-<MOD2>: Delete (DS-1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command deletes the line or facility by putting it out of service.
Note The DLT- does not support STS1, STS3C, STS12C, STS48C, VT1, and DS1 modifiers in Release 2.2.1.
Section
|
Description
|
Category
|
Other
|
Security
|
N/A
|
Related Messages
|
N/A
|
Input Format
|
DLT-<MOD2>:[TID]:<aid>:[CTAG];
where:
•aid is the AID ALL
|
Example
|
Input
DLT-EC1:CISCO:FAC-1-1:123;
|
Errors
|
This message generates all the default errors
|
11.11.5 DLT-CRS-<STS_PATH>: Delete Cross Connect (STS1, STS3C, STS12C)
This command deletes a cross-connect between STS paths. STS paths are specified using their STS AID.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
N/A
|
Related Messages
|
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
|
Input Format
|
DLT-CRS-<STS_PATH>:[TID]:<from>,<to>:[CTAG]:::;
where:
•from is the source aid of the cross sts connection and is the AID sts
•to is the destination aid of the crs sts connection and is the AID sts
|
Example
|
Input
DLT-CRS-STS12C:VINBURG:STS-1-1, STS-12-1:102:::;
|
Errors
|
This message generates all the default errors
|
11.11.6 DLT-CRS-VT1: Delete Cross Connect Virtual Tributary
This command deletes the VT1 cross connects.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
N/A
|
Related Messages
|
DLT-CRS-<STS_PATH>
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
|
Input Format
|
DLT-CRS-VT1:[TID]:<from>,<to>:[CTAG]:::;
where:
•from is the source aid of the vt connection and is the AID vt1_5
•to is the destination aid of the crs vt connection and is the AID vt1_5
|
Example
|
Input
DLT-CRS-VT1:CISCO:VT1-2-3-1,VT1-4-4-1:1234:::;
|
Errors
|
This message generates all the default errors
|
11.11.7 DLT-EQPT: Delete Equipment
This command deletes a card from the NE. It removes the card type and attributes that were entered for a particular slot. If any facilities are assigned, they are also deleted as long as they do not contain any cross-connect end-points, the cards are not in a protection group and they are not in SDCC termination. If any of the above descriptions exist, the command will be denied.
Section
|
Description
|
Category
|
Equipment
|
Security
|
N/A
|
Related Messages
|
DLT-FFP-EQPT RLS-PROTNSW-EQPT
ED-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
DLT-EQPT:[TID]:<eqpt_aid>:[CTAG];
where:
•equip_aid is the AID eqpt
|
Example
|
Input
DLT-EQPT:SONOMA:SLOT-1:104;
|
Errors
|
This message generates all the default errors
|
11.11.8 DLT-FFP-<OCN_TYPE>: Delete Facilities Protection Group (OC3, OC12, OC48)
This command deletes a linear protected group on optical cards.
Section
|
Description
|
Category
|
Facility Protection
|
Security
|
N/A
|
Related Messages
|
N/A
|
Input Format
|
DLT-FFP-<OCN_TYPE>:[TID]:<work>,<protect>:[CTAG];
where:
•work is the working equipment and the AID facility
•protect is the protection equipment and the AID facility
|
Example
|
Input
DLT-FFP-OC3:PETALUMA:FAC-2-1,FAC-1-1:1;
|
Errors
|
This message generates all the default errors
|
11.11.9 DLT-FFP-EQPT: Delete Facilities Protection Equipment
This command deletes an equipment protection group.
Section
|
Description
|
Category
|
Equipment
|
Security
|
N/A
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
ED-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
DLT-FFP-EQPT:[TID]:<work>,<protect>:[CTAG];
where:
•work is the AID eqpt
•protect is the AID eqpt
|
Example
|
Input
DLT-FFP-EQPT:PETALUMA:SLOT-2,SLOT-1:1;
|
Errors
|
This message generates all the default errors
|
11.11.10 DLT-USER-SECU: Delete User Security
This command removes a user and can only be used by an administrator. The AID block contains the user identifier. If this command is executed while the user is logged on, the current session for that user continues. Once the user logs out, the same userid cannot be used to log in again. This command is defined in TR-835.
Section
|
Description
|
Category
|
Security
|
Security
|
Admin
|
Related Messages
|
ACT-USER
CANC-USER
ED-PID
ED-USER-SECU
ENT-USER-SECU
|
Input Format
|
DLT-USER-SECU:[TID]:<username>:[CTAG];
where:
•username is a String
|
Example
|
Input
DLT-USER-SECU:CISCO:UID:123;
|
Errors
|
This message generates all the default errors
|
11.11.11 ED-<OCN_TYPE>: Edit (OC3, OC12, OC48)
This command modifies the attributes (i.e. service parameters) and state of an OC-N facility. Allowable states for a facility are Out of Service (OOS) and In Service (IS).
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::[SDCC=<sdcc>], [PJMON=<pjmon>],[SFBER=<sfber>],[SDBER=<sdber>], [MODE=<opticalMode>]:[<pst>]:;
Note If changing the pst field only, use the following Input Format:
ED-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::[<pst>]:;
where:
•fac_aid is the AID facility
•sdcc enables the Section DCC for this facility and is of type SDCC_MODE
•pjmon is the number of the STS facility to monitor for pointer justifications pjmon is an Integer
•sfber is of type SF_BER
•sdber is of type SD_BER
•opticalMode is of type OPTICAL_MODE
•pst is the card primary state and is of type PST
|
Example
|
Input
ED-OC48:PENNGROVE:FAC-6-1:114::SDCC=Y,PJMON=48,SFBER=1E-4, SDBER=1E-6, MODE=SONET:IS:;
|
Errors
|
This message generates all the default errors
|
11.11.12 ED-<STS_PATH>: Edit (STS1, STS3C, STS12C)
This command is used to modify the attributes associated with an STS path.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-<STS_PATH>:[TID]:<sts_aid>:[CTAG]::[SFBER=[<sfber>], [SDBER=<sdber>]::;
where:
•sts_aid is the AID sts
•sfber is of type SF_BER
•sdber is of type SD_BER
|
Example
|
Input
ED-STS1:FERNDALE:STS-2-4:115::SFBER=1E-3,SDBER=1E-5::;
|
Errors
|
This message generates all the default errors
|
11.11.13 ED-BITS: Edit Building Integrated Timing Supply
This command modifies BITS reference attributes.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-BITS:[TID]:<bits_aid>:[CTAG]::[LNCDE=<line_code>], [FRMF=<frame_format>]:<pst>:;
where:
•bits_aid is the AID bits
•line_code is the BITS line code and is of type LINE_CODE
•frame_format is the BITS frame format and is of type FRAME_FORMAT
•pst is the BITS state and is of type PST
|
Example
|
Input
ED-BITS:SONOMA:BITS-2:779::LNCDE=AMI,FRMF=ESF:IS;
|
Errors
|
This message generates all the default errors
|
11.11.14 ED-CRS-<STS_PATH>: Edit Cross Connect (STS1, STS3C, STS12C)
This command modifies attributes of an STS-level cross-connect. Under certain circumstances, you may change the cross-connect type (e.g. from 1WAY to 2WAY).
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Read/Write
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
|
Input Format
|
ED-CRS-<STS_PATH>:[TID]:<from>,<dst>:[CTAG]::<cct>::;
where:
•from is the source aid of the cross sts connection and is the AID sts
•dst is the AID sts
•cct is the cross connection type and is of type CCT
|
Example
|
Input
ED-CRS-STS3C:KENWOOD:STS-6-4,STS-12-7:108::2WAY::;
|
Errors
|
This message generates all the default errors
|
11.11.15 ED-CRS-VT1: Edit Cross Connect Virtual Tributary
This command edits the VT1.5 cross-connect.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Read/Write
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
|
Input Format
|
ED-CRS-VT1:[TID]:<from>,<to>:[CTAG]::<cct>::;
where:
•from is the AID vtl_5
•to is the AID vtl_5
•cct is the cross connection type and is of type CCT
|
Example
|
Input
ED-CRS-VT1:CISCO:VT1-2-1-1,VT1-4-1-1:1234::1WAY::;
|
Errors
|
This message generates all the default errors
|
11.11.16 ED-DAT: Edit Date and Time
This command edits the date and time.
Section
|
Description
|
Category
|
System
|
Security
|
Read/Write
|
Related Messages
|
ACT-USER
ALW-MSG-ALL
CANC-USER
INH-MSG-ALL
INIT-SYS
RTRV-HDR
|
Input Format
|
ED-DAT:[TID]::[CTAG]::[<date>],[<time>];
where:
•date is the date field YYYY-MM-DD or YY-MM-DD; date is a String
•time is the time field HH-MM-SS, the hours 0..24; time is a String
|
Example
|
Input
ED-DAT:TID::1234::99-12-21,14-35-15;
|
Errors
|
This message generates all the default errors
|
11.11.17 ED-EC1: Edit Electrical Carrier Level 1
This command edits EC-1 facilities. This command will edit the properties of an EC-1 card port.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-EC1:[TID]:<fac>:[CTAG]::[PJMON=<pjmon>][,][LBO=<lbo>]:<pst>:;
where:
•fac is the facility aid. fac is the AID facility
•pjmon is the SONET pointer number 0 or 1 and is an Integer
•lbo is the line buildout and is of type E_LBO
•pst is the port state and is of type PST
|
Example
|
Input
ED-EC1:CISCO:FAC-1-1:123::PJMON=0,LBO=0-225:IS:;
|
Errors
|
This message generates all the default errors
|
11.11.18 ED-FFP-<OCN_TYPE>: Edit Facilities Protection Group (OC3, OC12, OC48)
This command edits the optical facility protection.
Section
|
Description
|
Category
|
Facility Protection
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-FFP-<OCN_TYPE>:[TID]:<facility>:[CTAG]::[NAME=<name>], [RVTT=<revertiveType>],[RVTM=<revertiveTime>],[BSWM=<bswMode>];
where:
•facility is the facility aid and is the AID facility
•name is the protection name and is a String
•revertiveType is of type REVERTIVE_TYPE
•revertiveTime is of type REVERTIVE_TIME
•bswMode specifies if it is a bidirectional switch mode and is of type ON_OFF
|
Example
|
Input
ED-FFP-OC3:PETALUMA:FAC-1-1:1::NAME=PROT_NAME,RVTT=R, RVTM=1.0,BSWM=OFF;
|
Errors
|
This message generates all the default errors
|
11.11.19 ED-FFP-EQPT: Edit Equipment Protection
This command edits an equipment protection group.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read/Write
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
ED-FFP-EQPT:[TID]:<eqpt>:[CTAG]::[NAME=<name>], [RVTT=<revertiveType>],[RVTM=<revertiveTime>];
where:
•eqpt is the equipment aid and is the AID eqpt
•name is the name of the group and is a String
•revertiveType is of type REVERTIVE_TYPE
•revertiveTime is of type REVERTIVE_TIME
|
Example
|
Input
ED-FFP-EQPT:PETALUMA:SLOT-1:1::NAME=PROT_NAME,RVTT=R, RVTM=1.0;
|
Errors
|
This message generates all the default errors
|
11.11.20 ED-NE: Edit Network Element
This command modifies the attributes of the NE system such as changing the node's identity (e.g. IP address), external interfaces (e.g. LAN ports), and major modes of operation (e.g. SONET vs. SDH).
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
ED-NE:[TID]::[CTAG]:::[NAME=<name>],[IPADDR=<ipaddr>], [IPMASK=<ipmask>],[DEFRTR=<defrtr>],[TMMD=<timing_mode>], [SSMG=<sync_gen>],[NSQL=<sync_quality_level>];
where:
•name is the System Identifier (SID/TID) of the NE and must be 20 characters or less; name is a String
•ipaddr is the IP address of the NE on the local LAN and is a String
•ipmask is the IP Mask used to identify the sub-net on which the NE resides; ipmask is a String
•defrtr is the IP address of the default router and is a String
•timing_mode is of type TIMING_MODE
•sync_gen is of type SYNC_GENERATION
•sync_quality_level is of type SYNC_QUALITY_LEVEL
|
Example
|
Input
ED-NE:LKVLL::111:::NAME=LAKEVILLE,IPADDR=192.168.100.52, IPMASK=255.255.255.0,DEFRTR=192.168.100.1,TMMD=LINE, SSMG=GEN1,NSQL=ABOVE-PRS;
|
Errors
|
This message generates all the default errors
|
11.11.21 ED-PID: Edit Private Identifier
This command allows a user to change their own password. Other user identification and access changes may only be made by a superuser. This command is defined in TR-835.
Note The password cannot be null. It will be echoed as clear text as the message is parsed and only after the complete message is entered and terminated.
Note The password should not appear in the TL1 log on the NE.
Section
|
Description
|
Category
|
Security
|
Security
|
Read/Write
|
Related Messages
|
ACT-USER
CANC-USER
DLT-USER-SECU
ED-USER-SECU
ENT-USER-SECU
|
Input Format
|
ED-PID:[TID]:<username>:[CTAG]::<oldPassword>,<newPassword>;
where:
•username is a String
•oldPassword is a String
•newPassword is a String
|
Example
|
Input
ED-PID:CISCO:UID:123::OLD_PASSWORD,NEW_PASSWORD;
|
Errors
|
This message generates all the default errors
|
11.11.22 ED-SYNCN: Edit Synchronization
This command modifies the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources may be specified (for example, PRIMARY, SECOND, THIRD).
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read/Write
|
Related Messages
|
REPT ALM SYNCN
REPT EVT SYNCN
RTRV-ALM-SYNCN
RTRV-COND-SYNCN
RTRV-SYNCN
|
Input Format
|
ED-SYNCN:[TID]:<sync_aid>:[CTAG]:::[PRIMARY=<primary>], [SECOND=<second>],[THIRD=<third>]:;
where:
•sync_aid is the synchronization reference to be modified; sync_aid is the AID sync_ref and is listable
•primary is the AID syn_src
•second is the AID syn_src
•third is the AID syn_src
|
Example
|
Input
ED-SYNCN:BOYES:SYNC-NE:112:::PRIMARY=INTERNAL, SECOND=INTERNAL,THIRD=INTERNAL:;
|
Errors
|
This message generates all the default errors
|
11.11.23 ED-T1: Edit T1
This command modifies the attributes related to a DS-1 port.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
ED-T3
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-T1
RLS-LPBK-T3
RTRV-T1
RTRV-T3
|
Input Format
|
ED-T1:[TID]:<tl1_aid>:[CTAG]::[ID=<id>],[LNCDE=<line_code>], [FRMF=<frame_format>],[LBO=<line_buildout>]:[<pst>]:;
where:
•t1_aid is the AID facility
•id is a String
•line_code is the port line code and is of type LINE_CODE
•frame_format is of type FRAME_FORMAT
•line_buildout is the port line buildout and is of type LINE_BUILDOUT
•pst is of type PST
|
Example
|
Input
ED-T1:CISCO:FAC-1-1:1223::ID=CISCO,LNCDE=AMI,FRMF=ESF, LBO=0-131:IS:;
|
Errors
|
This message generates all the default errors
|
11.11.24 ED-T3: Edit T3
This command edits a DS-3 and DS-3 transmux card.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
ED-T1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-T1
RLS-LPBK-T3
RTRV-T1
RTRV-T3
|
Input Format
|
ED-T3:[TID]:<facility>:[CTAG]::[LNTYPE=<lineType>], [LNCODE=<lineCode>],[LB0=<lbo>][<pst>];
where:
•facility is the AID facility
•lineType is the port line type and is of type DS_LINE_TYPE
•lineCode is the line code and is the lineCode of the DS3XM card; lineCode is of type DS_LINE_CODE
•lbo is the circuit line buildout and is of type E_LBO
•pst is of type PST
|
Example
|
Input
ED-T3:CISCO:FAC-1-2:123::LNTYPE=C-BIT,LNCODE=B3ZS,LBO=0-225: IS:;
|
Errors
|
This message generates all the default errors
|
11.11.25 ED-USER-SECU: Edit User Security
This command edits a user's privileges, password, or ID. Only a user with R/W admin privileges may perform this operation. Privilege levels are described in the ENT-USER-SECU: Enter User Security command. This command is defined in TR-835.
Note If the password is changed with this command, the password should be blanked out in the TL1 log.
Section
|
Description
|
Category
|
Security
|
Security
|
Admin
|
Related Messages
|
ACT-USER
CANC-USER
DLT-USER-SECU
ED-PID
ENT-USER-SECU
|
Input Format
|
ED-USER-SECU:[TID]:<username>:[CTAG]::[PASSWORD=<password>], [PRIVILEGE=<privilege>];
where:
•username is a String
•password is a String
•privilege is of type PRIVILEGE
|
Example
|
Input
ED-USER-SECU:CISCO:UID:123::PASSWORD=PASSWORD, PRIVILEGE=MAINT;
|
Errors
|
This message generates all the default errors
|
11.11.26 ENT-<MOD2>: Enter (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command puts a facility or an aid in service.
Note ENT-DS1/STS1/STS3C/STS12C/STS48C/VT1 are not supported in Release 2.2.1.
Section
|
Description
|
Category
|
Other
|
Security
|
Admin
|
Related Messages
|
N/A
|
Input Format
|
ENT-<MOD2>:[TID]:<aid>:[CTAG];
where:
•aid is the aid to be put in service and is the AID ALL
|
Example
|
Input
ENT-OC3:CISCO:FAC-1-1:1243;
|
Errors
|
This message generates all the default errors
|
11.11.27 ENT-CRS-<STS_PATH>: Enter Cross Connect (STS1, STS3C, STS12C)
This command creates an STS cross-connect between two or more STS paths. Rather than create each individual unidirectional connection singularly, this command accepts cross-connection types (CCT) that identify aggregate cross-connects based on their function in the network. To enter a cross-connect, the facilities that support the STS paths must be either in service or out of service assigned. If a cross-connect (XC) card is not present in the system or if the paths have incompatible payload types, the request is denied.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Admin
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
RTRV-CRS-VT1
|
Input Format
|
ENT-CRS-<STS_PATH>:[TID]:<from>,<to>:[CTAG]::<cct>::;
where:
•from is the source aid of the cross sts connection and is the AID sts
•to is the destination aid of the crs sts connection and is the AID sts
•cct is the cross connection type and is of type CCT
|
Example
|
Input
ENT-CRS-STS1:BODEGA:STS-1-5,STS-2-5:116::2WAY::;
|
Errors
|
This message generates all the default errors
|
11.11.28 ENT-CRS-VT1: Enter Cross Connect Virtual Tributary
This command creates a VT1 cross connect.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Admin
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
RTRV-CRS-<STS_PATH}>
RTRV-CRS-VT1
|
Input Format
|
ENT-CRS-VT1:[TID]:<from>,<to>:[CTAG]::<cct>::;
where:
•from is the source aid of the cross vt connection and is the AID vt1_5
•to is the destination aid of the crs vt connection and is the AID vt1_5
•cct is the cross connection type and is of type CCT
|
Example
|
Input
ENT-CRS-VT1:CISCO:VT1-2-3-14,VT1-4-4-12:1234::1WAY::;
|
Errors
|
This message generates all the default errors
|
11.11.29 ENT-EQPT: Enter Equipment
This command enters the card type and attributes for a given equipment slot in the NE. It also automatically enters all facilities supported by the card, assigning default values to all facility and path attributes.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Admin
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-EQPT
ED-FFP-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
ENT-EQPT:[TID]:<eqpt>:[CTAG]::<eqpt_type>;
where:
•eqpt is the AID eqpt
•eqpt_type is of type EQUIPMENT_TYPE
|
Example
|
Input
ENT-EQPT:PETALUMA:SLOT-12:118::OC12;
|
Errors
|
This message generates all the default errors
|
11.11.30 ENT-FFP-<OCN_TYPE>: Enter Facilities Protection Group (OC3, OC12, OC48)
This command creates an optical protection.
Section
|
Description
|
Category
|
Facility Protection
|
Security
|
Admin
|
Related Messages
|
N/A
|
Input Format
|
ENT-FFP-<OCN_TYPE>:[TID]:<work>,<protect>:[CTAG]::[NAME=<name>], [RVTM=<rvtm>],[RVTT=<rvtt>],[BSWM=<bswMode>];
where:
•work is the working unit aid and is the AID facility
•protect is the protection unit aid and is the AID facility
•name is the protection name and is a String
•rvtm is the revertive mode and is of type REVERTIVE_TYPE
•rvtt is the revertive time and of type REVERTIVE_TIME
•bswMode specifies if it is bidirectional switch mode and is of type ON_OFF
|
Example
|
Input
ENT-FFP-OC3:PETALUMA:FAC-2-1,FAC-1-1:1::NAME=PROT_NAME, RVTM=R,RVTT=1.0,BSWM=OFF;
|
Errors
|
This message generates all the default errors
|
11.11.31 ENT-FFP-EQPT: Enter Equipment Protection
This command creates an equipment protection.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Admin
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-EQPT
ED-FFP-EQPT RTRV-COND-EQPT
ENT-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
ENT-FFP-EQPT:[TID]:<work>,<protect>:[CTAG]::PRT=<protectionGroup>, [NAME=<name>],[RVTM=<rvtm>],[RVTT=<rvtt>];
where:
•work is the AID eqpt
•protect is the AID eqpt
•protectionGroup is the protection group 1-1 or 1-N and is of type PROTECTION_GROUP
•name is the protection name and is a String
•rvtm is the revertive mode and is of type REVERTIVE_TYPE
•rvtt is the revertive time and is of type REVERTIVE_TIME
|
Example
|
Input
ENT-FFP-EQPT:PETALUMA:SLOT-2,SLOT-1:1::PRT=1-1, NAME=PROT_NAME,RVTM=R,RVTT=1.0;
|
Errors
|
This message generates all the default errors
|
11.11.32 ENT-USER-SECU: Enter User Security
This command adds a user account. Only administrators may do this. The AID block contains the user identifier. See .
There are seven security levels defined for the TalonMX. Each user may be configured as possessing 1or more of these seven privileges.
1 Read-Only Alarms: Users possessing this security level can retrieve and receive autonomous alarms.
2 Read-Write Alarms: Users possessing this security level can manage as well as receive/retrieve alarm information.
3 Read-Only Provisioning: Users possessing this security level can retrieve TalonMX provisioning values.
4 Read-Write Provisioning: Users possessing this security level can set/retrieve TalonMX provisioning values.
5 Read-Only Administrative: Users possessing this security level can retrieve TalonMX security settings.
6 Read-Write Administrative: Users possessing this security level can set/retrieve TalonMX security settings.
7 Read-Write Maintenance: Users possessing this security level can perform maintenance functions such as operating/releasing loopbacks.
A superuser will have all privileges shown above.
This command is defined in TR-835.
Section
|
Description
|
Category
|
Security
|
Security
|
Admin
|
Related Messages
|
ACT-USER
CANC-USER
DLT-USER-SECU
ED-PID
ED-USER-SECU
|
Input Format
|
ENT-USER-SECU:[TID]:<username>:[CTAG]::<password>,<privilege>;
where:
•username is a String
•password is the user login password and is a String
•privilege is the user security level and is of type PRIVILEGE; Superuser=super, Provision=prov, Maintenance=maint, Retrieve=rtrv
|
Example
|
Input
ENT-USER-SECU:CISCO:UID:123::PSWD,MAINT;
|
Errors
|
This message generates all the default errors
|
11.11.33 INH-MSG-ALL: Inhibit Message All
This command instructs the NE to enter a mode that prevents all automatic messages from being transmitted.
Section
|
Description
|
Category
|
System
|
Security
|
N/A
|
Related Messages
|
ACT-USER
ALW-MSG-ALL
CANC-USER
ED-DAT
INIT-SYS
RTRV-HDR
|
Input Format
|
INH-MSG-ALL:[TID]::[CTAG]::,,;
|
Example
|
Input
INH-MSG-ALL:PETALUMA::550::,,;
|
Errors
|
This message generates all the default errors
|
11.11.34 INIT-REG-<MOD2>: Initialize Register (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command initializes the performance monitoring registers.
Section
|
Description
|
Category
|
Performance
|
Security
|
Read/Write
|
Related Messages
|
RTRV-PM-<MOD2>
RTRV-TH-<MOD2>
SET-TH-<MOD2>
|
Input Format
|
INIT-REG-<MOD2>:[TID]:<aid>:[CTAG]::,,,,<tmpr>,,;
where:
•aid is the AID facility
•tmpr is of type TMPR
|
Example
|
Input
INIT-REG-OC3:TID:FAC-1-1:1234::,,,,15MIN,,;
|
Errors
|
This message generates all the default errors
|
11.11.35 INIT-SYS: Initialize System
This command instructs the NE to initialize the specified card and its associated subsystem(s). The command supports various levels of restart, called phases, ranging from a warm start to a cold start.
Note In Release 2.2.1 this command only resets equipment. The phase parameter is not supported in this release.
Section
|
Description
|
Category
|
System
|
Security
|
Read/Write
|
Related Messages
|
ACT-USER
ALW-MSG-ALL
CANC-USER
ED-DAT
INH-MSG-ALL
RTRV-HDR
|
Input Format
|
INIT-SYS:[TID]:<eqpt_aid>:[CTAG]::[<phase>];
where:
•eqpt-aid is the AID eqpt
•phase is the level of initialization to take place; the higher the number the stronger the reset, A phase=1 is a warm start and A phase=10 is a cold start; phase is an Integer
|
Example
|
Input
INIT-SYS:HOTWATER:SLOT-1:201::3;
|
Errors
|
This message generates all the default errors
|
11.11.36 OPR-LPBK-<OCN_TYPE>: Operate Loopback (OC3, OC12, OC48)
This command instructs the NE to operate a loopback on a specified OC-N facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
OPR-LPBK-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::,,,,<lpbktype>;
where:
•fac_aid is the AID facility
•lpbktype identifies the type of loopback (Terminal or Facility) to be established and is of type LPBK_TYPE
|
Example
|
Input
OPR-LPBK-OC3:PTREYES:FAC-5-12:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.37 OPR-LPBK-DS1: Operate Loopback Digital Signal Level 1
This command operates a DS-1 signal loopback on a DS3XM-6 card.
Note The TERMINAL loopback type is not supported for this command.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
OPR-LPBK-DS1:[TID]:<ds>:[CTAG]::,,,<lpbkType>;
where:
•ds is the aid for the DS3XM card on the ds-1 and is the AID ds-1
•lpbkType is the loop back type
Note The terminal loop back type is not supported for the DS3XM in Release 2.2.1. lpbkType is of type LPBK_TYPE
|
Example
|
Input
OPR-LPBK-DS1:PTREYES:DS1-4-2-13:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.38 OPR-LPBK-EC1: Operate Loopback Electrical Carrier Level 1
This command operates the loopback on an EC-1 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
OPR-LPBK-EC1:[TID]:<facility>:[CTAG]::,,,<lpbkType>;
where:
•facility is the facility aid for the EC-1 and is the AID facility
•lpbkType is the loop back type and is of type LPBK_TYPE
|
Example
|
Input
OPR-LPBK-EC1:PTREYES:FAC-4-2:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.39 OPR-LPBK-T1: Operate Loopback T1
This command operates the loopback for a DS-1 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
ED-T1
ED-T3
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
RTRV-T1
RTRV-T3
|
Input Format
|
OPR-LPBK-T1:[TID]:<fac>:[CTAG]::,,,<lpbk_type>;
where:
•fac is the AID facility
•lpbk_type is the loop back type for the DS-1 cards and is of type LPBK_TYPE
|
Example
|
Input
OPR-LPBK-T1:PTREYES:FAC-4-12:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.40 OPR-LPBK-T3: Operate Loopback T3
This command instructs the NE to operate a loopback on a specified T3 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
ED-T1 RLS-LPBK-DS1
ED-T3 RLS-LPBK-EC1
OPR-LPBK-<OCN_TYPE> RLS-LPBK-T1
OPR-LPBK-DS1 RLS-LPBK-T3
OPR-LPBK-EC1 RTRV-T1
OPR-LPBK-T1 RTRV-T3
RLS-LPBK-<OCN_TYPE>
|
Input Format
|
OPR-LPBK-T3:[TID]:<fac_aid>:[CTAG]::,,,<lpbktype>;
where:
•fac_aid is the AID facility
•lpbktype identifies the loopback type (Terminal or Facility) to be established and is of type LPBK_TYPE
|
Example
|
Input
OPR-LPBK-T3:SCHELLVILLE:FAC-2-11:202::,,,TERMINAL;
|
Errors
|
This message generates all the default errors
|
11.11.41 OPR-PROTNSW-<OCN_TYPE>: Operate Protection Switch (OC3, OC12, OC48)
This command instructs the NE to initiate a SONET line protection switch request. User switch requests initiated with this command remain active until they are released via the RLS-PROTNSW-OCN command or are overridden by a higher priority protection switch request.
Section
|
Description
|
Category
|
Switch
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
OPR-PROTNSW-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::<dnField>;
where:
•fac_aid is the AID facility and is listable
•dnField is the switch mode and is of type SWITCH
|
Example
|
Input
OPR-PROTNSW-OC48:CHICKALUMA:FAC-2-1:204::LOCKOUT;
|
Errors
|
This message generates all the default errors
|
11.11.42 OPR-PROTNSW-EQPT: Operate Protection Switch Equipment
This command initiates a protection switch. The RLS-PROTNSW-EQPT command can be used to release a switch condition.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read/Write
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-EQPT
ED-FFP-EQPT RTRV-COND-EQPT
ENT-EQPT RTRV-EQPT
ENT-FFP-EQPT RTRV-FFP-EQPT
REPT ALM EQPT SW-DX-EQPT
REPT EVT EQPT
|
Input Format
|
OPR-PROTNSW-EQPT:[TID]:<eqpt_aid>:[CTAG]::<sc>;
where:
•eqpt_aid is the equipment aid and is the AID eqpt
•sc is the protection switch mode and is of type PROT_MOD_OP
|
Example
|
Input
OPR-PROTNSW-EQPT:LASLOMAS:SLOT-1:205::FRCD;
|
Errors
|
This message generates all the default errors
|
11.11.43 OPR-UPGRADE: Operate Upgrade
This command operates upgrades.
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
OPR-UPGRADE:[TID]:<eqpt_aid>:[CTAG];
where:
•eqpt_aid is the AID eqpt
|
Example
|
Input
OPR-UPGRADE:FOUNTAINGROVE:SLOT-1:204;
|
Errors
|
This message generates all the default errors
|
11.11.44 REPT ALM <MOD2>: Report Alarm (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
Reports an alarm condition against a facility or a line.
Note The STS alarms are reported as STS1 alarms.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM BITS RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-ENV
REPT ALM EQPT RTRV-ALM-EQPT
REPT ALM SYNCN RTRV-ALM-SYNCN
REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT EVT EQPT RTRV-COND-ALL
REPT EVT SYNCN RTRV-COND-BITS
RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT
RTRV-ALM-ALL RTRV-COND-SYNCN
|
Output Format
|
SID DATE TIME ** ATAG REPT ALM <MOD2ALM> "<ds1Aid>:<ntfcncde>,<condition>,<srveff>,,,,:[<desc>],<eqptType>" ;
where:
•ds1aid is the AID ds1
•ntfcncde is the 2-letter notification code and is of type NOTIF_CODE
•condition is of type CONDITION
•srveff is the effect on service caused by the alarm condition; srveff is of type SERV_EFF.
•desc is a String
•eqptType is of type EQPT_TYPE
|
Example
|
Output
TID-000 98-06-20 14-30-00 ** 001 REPT ALM DS1 "DS1-14-3-5:MJ,LPBKFACILITY,SA,,,,:\"LOOP BACK ACTIVE\", DS3XM-6" ;
|
11.11.45 REPT ALM BITS: Report Alarm Building Integrated Timing Supply
Reports an alarm condition on a BITS facility.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-ENV
REPT ALM EQPT RTRV-ALM-EQPT
REPT ALM SYNCN RTRV-ALM-SYNCN
REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT EVT EQPT RTRV-COND-ALL
REPT EVT SYNCN RTRV-COND-BITS
RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT
RTRV-ALM-ALL RTRV-COND-SYNCN
|
Output Format
|
SID DATE TIME ** ATAG REPT ALM BITS "<bits_aid>:<ntfcncde>,<condition>,<srveff>,,,,:[<desc>]" ;
where:
•bits_aid is the AID bits
•ntfcncde is the 2-letter notification code and is of type NOTIF_CODE
•condition is a type of alarm condition and is of type CONDITION
•srveff is the effect on service caused by the alarm condition; srveff is of type SERV_EFF
•desc is a String
|
Example
|
Output
TID-000 98-06-20 14-30-00 ** 001 REPT ALM BITS "BITS-1:MJ,SYNC,SA,,,,:\"LOSS OF TIMING\"," ;
|
11.11.46 REPT ALM ENV: Report Alarm Environment
Reports a customer-defined condition on an environmental alarm input.
Section
|
Description
|
Category
|
Environment
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM BITS RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
RTRV-ALM-ALL
|
Output Format
|
SID DATE TIME ** ATAG REPT ALM ENV "<env_aid>:<ntfcnnde>,<almtype>,,,<desc>" ;
where:
•env_aid is AID env
•ntfcncde is of type NOTIF_CODE
•almtype is of type ENV_ALM
•desc is a String
|
Example
|
Output
TID-000 98-06-20 14-30-00 ** 001 REPT ALM ENV "ENV-IN-1:MJ,OPENDR,,,\"OPEN DOOR\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.47 REPT ALM EQPT: Report Alarm Equipment
Reports an alarm condition against an equipment unit or slot.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT RTRV-ALM-<MOD2ALM>
DLT-FFP-EQPT RTRV-ALM-ALL
ED-FFP-EQPT RTRV-ALM-BITS
ENT-EQPT RTRV-ALM-ENV
ENT-FFP-EQPT RTRV-ALM-EQPT
OPR-PROTNSW-EQPT RTRV-ALM-SYNCN
REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT ALM BITS RTRV-COND-ALL
REPT ALM ENV RTRV-COND-BITS
REPT ALM SYNCN RTRV-COND-EQPT
REPT EVT <MOD2ALM> RTRV-COND-SYNCN
REPT EVT EQPT RTRV-EQPT
REPT EVT SYNCN RTRV-FFP-EQPT
RLS-PROTNSW-EQPT SW-DX-EQPT
|
Output Format
|
SID DATE TIME ** ATAG REPT ALM EQPT "<eqpt>:<ntfcncde>,<condition>,<srveff>,,,,,<desc>,<eqptType>" ;
where:
•eqpt is the equipment aid SLOT-{1-17} and is the AID eqpt
•ntfcncde is the 2-letter notification code and is of type NOTIF_CODE
•condition is the type of alarm condition and is of type CONDITION
•srveff is the effect on service caused by the alarm condition and is of type SERV_EFF
•desc is a String
•eqptType is of type EQPT_TYPE
|
Example
|
Output
TID-000 98-06-20 14-30-00 ** 001 REPT ALM EQPT "SLOT-7:MN,CONTR,NSA,,,,:\"CONTROLLER FAILURE\",TCC" ;
|
11.11.48 REPT ALM SYNCN: Report Alarm Synchronization
Reports an alarm condition against a synchronization reference.
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read Only
|
Related Messages
|
ED-SYNCN RTRV-ALM-BITS
REPT ALM <MOD2ALM> RTRV-ALM-ENV
REPT ALM BITS RTRV-ALM-EQPT
REPT ALM ENV RTRV-ALM-SYNCN
REPT ALM EQPT RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
RTRV-ALM-ALL RTRV-SYNCN
|
Output Format
|
SID DATE TIME ** ATAG REPT ALM SYNCN "<sync_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>" ;
where:
•sync_aid is the identifier of Synchronization Reference with alarm condition; sync_aid is the AID sync_ref
•ntfcncde is the 2-letter notification code and is of type NOTIF_CODE
•condition is the type of alarm condition and is of type CONDITION
•srveff is the effect on service caused by the alarm condition and is of type SERV_EFF
•desc is a String
|
Example
|
Output
TID-000 98-06-20 14-30-00 ** 001 REPT ALM SYNCN "SYNC-NE:MJ,MAN,SA,,,,:\"MANUAL SWITCH\"," ;
|
11.11.49 REPT EVT <MOD2ALM>: Report Event (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
Reports the occurrence of a non-alarmed event.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM BITS RTRV-ALM-ENV
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT EQPT RTRV-COND-ALL
REPT EVT SYNCN RTRV-COND-BITS
RTRV-ALM-<MOD2ALM> RTRV-COND-EQPT
RTRV-ALM-ALL RTRV-COND-SYNCN
|
Output Format
|
SID DATE TIME A ATAG REPT EVT <MOD2ALM> "<fac_aid>:<condition>,[<condeff>],,,[<location>],,[<monval>], [<th_val>],[<tmpr>]:<desc>,<eqptType>" ;
where:
•fac_aid is the identifier of the OC-N facility with the condition and is the AID facility
•condition is of type CONDITION
•condeff is the effect of the condition on the NE; condeff is of type COND_EFF and is optional
•location is of type LOCATION and is optional
•monval is the monitored value and is optional
•th_val is the threshold value; th_val is an Integer and is optional
•tmpr is the time period; tmpr is of type TMPR and is optional
• desc is a String
•eqptType is of type EQPT_TYPE
|
Example
|
Output
TID-000 98-06-20 14-30-00 A 001 REPT EVT T3 "FAC-4-1:WKSWPR,TC,,,FEND,,12,13,15MIN:\"WORKING SWITCH TO PROTECTION\",DS3-12" ;
|
11.11.50 REPT EVT EQPT: Report Event Equipment
Reports the occurrence of a non-alarmed event against an equipment unit or slot.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT RTRV-ALM-<MOD2ALM>
DLT-FFP-EQPT RTRV-ALM-ALL
ED-FFP-EQPT RTRV-ALM-BITS
ENT-EQPT RTRV-ALM-ENV
ENT-FFP-EQPT RTRV-ALM-EQPT
OPR-PROTNSW-EQPT RTRV-ALM-SYNCN
REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT ALM BITS RTRV-COND-ALL
REPT ALM ENV RTRV-COND-BITS
REPT ALM EQPT RTRV-COND-EQPT
REPT ALM SYNCN RTRV-COND-SYNCN
REPT EVT <MOD2ALM> RTRV-EQPT
REPT EVT SYNCN RTRV-FFP-EQPT
RLS-PROTNSW-EQPT SW-DX-EQPT
|
Output Format
|
SID DATE TIME A ATAG REPT EVT EQPT "<eqpt>:<condition>,<condeff>,<eqptType>,,,,,:[<desc>]" ;
where:
•eqpt is the slot number of the equipment and is the AID eqpt
•condition is the type of event and is of type CONDITION
•condeff is the effect of the condition on the NE; condeff is of type COND_EFF
•eqptType is the equipment type and is of type EQPT_TYPE
•desc is a String
|
Example
|
Output
TID-000 98-06-20 14-30-00 A 001 REPT EVT EQPT "SLOT-7:,PLUGIN,TC,TCC,,,,,:\"EQUIPMENT PLUG-IN\"," ;
|
11.11.51 REPT EVT SYNCN: Report Event Synchronization
Reports the occurrence of a non-alarmed event against a synchronization entity.
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read Only
|
Related Messages
|
ED-SYNCN RTRV-ALM-BITS
REPT ALM <MOD2ALM> RTRV-ALM-ENV
REPT ALM BITS RTRV-ALM-EQPT
REPT ALM ENV RTRV-ALM-SYNCN
REPT ALM EQPT RTRV-COND-<MOD2ALM>
REPT ALM SYNCN RTRV-COND-ALL
REPT EVT <MOD2ALM> RTRV-COND-BITS
REPT EVT EQPT RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
RTRV-ALM-ALL RTRV-SYNCN
|
Output Format
|
SID DATE TIME A ATAG REPT EVT SYNCN "<sync_aid>:<condition>,<condeff>,,,,,,:[<desc>]" ;
where:
•sync_aid is the identifier of the synchronization entity with the condition; sync_aid is the AID sync_ref
•condition is of type CONDITION
•condeff is of type COND_EFF
•desc is a String
|
Example
|
Output
TID-000 98-06-20 14-30-00 A 001 REPT EVT SYNCN "SYNC-NE:SWTOINT,SC,,,,,,:\"SWITCH TO INTERNAL CLOCK\"," ;
|
11.11.52 RLS-LPBK-<OCN_TYPE>: Release Loopback (OC3, OC12, OC48)
This command instructs the NE to release a loopback on the specified OC-N facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
RLS-LPBK-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::,,,[<lpbktype>];
where:
•fac_aid is the AID facility
•lpbktype is the type of loopback to be released and is of type LPBK_TYPE
|
Example
|
Input
RLS-LPBK-OC3:PTREYES:FAC-12-1:208::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.53 RLS-LPBK-DS1: Release Loopback Digital Signal Level 1
This command releases a DS-1 signal loopback for the DS3XM-6 card.
Note The TERMINAL loopback is not supported.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-EC1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
RLS-LPBK-DS1:[TID]:<ds1Aid>:[CTAG]::,,,[<lpbkType>];
where:
•ds1Aid is the AID ds1
•lpbkType is of type LPBK_TYPE
|
Example
|
Input
RLS-LPBK-DS1:PTREYES:DS1-4-2-13:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.54 RLS-LPBK-EC1: Release Loopback Electrical Carrier Level 1
This command releases loopback for an EC-1 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-T1
RLS-LPBK-T3
|
Input Format
|
RLS-LPBK-EC1:[TID]:<facility>:[CTAG]::,,,<lpbkType>;
where:
•facility is the AID facility
•lpbkType is of type LPBK_TYPE
|
Example
|
Input
RLS-LPBK-EC1:PTREYES:FAC-3-12:203::,,,FACILITY;
|
Errors
|
This message generates all the default errors
|
11.11.55 RLS-LPBK-T1: Release Loopback T1 Facility
This command instructs the NE to release the loopback for the T1 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
ED-T1
ED-T3
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T3
RTRV-T1
RTRV-T3
|
Input Format
|
RLS-LPBK-T1:[TID]:<fac>:[CTAG]::,,,[<lpbk_type>];
where:
•fac releases the loopback for a T1 facility. fac is the AID facility.
•lpbk_type is of type LPBK_TYPE.
|
Example
|
Input
RLS-LPBK-T1:PTREYES:FAC-1-12:203::,,,FACILITY;
|
Errors
|
This message generates all of the Default Errors.
|
11.11.56 RLS-LPBK-T3: Release Loopback T3 Facility
This command instructs the NE to release a loopback on the specified T3 facility.
Section
|
Description
|
Category
|
Testing
|
Security
|
Read/Write
|
Related Messages
|
ED-T1
ED-T3
OPR-LPBK-<OCN_TYPE>
OPR-LPBK-DS1
OPR-LPBK-EC1
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-<OCN_TYPE>
RLS-LPBK-DS1
RLS-LPBK-EC1
RLS-LPBK-T1
RTRV-T1
RTRV-T3
|
Input Format
|
RLS-LPBK-T3:[TID]:<fac_aid>:[CTAG]::,,,[<lpbk_type>];
where:
•fac_aid is the AID facility
•lpbktype is the type of loopback to be released; lpbktype is of type LPBK_TYPE.
|
Example
|
Input
RLS-LPBK-T3:SCHELLVILLE:FAC-6-11:207::,,,TERMINAL;
|
Errors
|
This message generates all the default errors
|
11.11.57 RLS-PROTNSW-<OCN_TYPE>: Release Protection Switch (OC3, OC12, OC48)
Instructs the NE to release a line protection switch request between a working line and a protection line.
Section
|
Description
|
Category
|
Switch
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
RLS-PROTNSW-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG];
where:
•fac_aid is the AID facility
|
Example
|
Input
RLS-PROTNSW-OC48:CHICKALUMA:FAC-6-1:209;
|
Errors
|
This message generates all the default errors
|
11.11.58 RLS-PROTNSW-EQPT: Release Protection Switch Equipment
This command instructs the NE to release a protection switch on an equipment unit.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read/Write
|
Related Messages
|
DLT-EQPT REPT EVT EQPT
DLT-FFP-EQPT RTRV-ALM-EQPT
ED-FFP-EQPT RTRV-COND-EQPT
ENT-EQPT RTRV-EQPT
ENT-FFP-EQPT RTRV-FFP-EQPT
OPR-PROTNSW-EQPT SW-DX-EQPT
REPT ALM EQPT
|
Input Format
|
RLS-PROTNSW-EQPT:[TID]:<eqpt_aid>:[CTAG];
where:
•eqpt_aid is the AID eqpt
|
Example
|
Input
RLS-PROTNSW-EQPT:LASLOMAS:SLOT-3:401;
|
Errors
|
This message generates all the default errors
|
11.11.59 RMV-<MOD2>: Remove (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command removes a facility from an in service state to out of service.
Note RMV-DS1/STS1/STS3C/STS12C/STS48C/VT1 are not supported in Release 2.2.1.
Section
|
Description
|
Category
|
Facility
|
Security
|
N/A
|
Related Messages
|
N/A
|
Input Format
|
RMV-<MOD2>:[TID]:<facility>:[CTAG];
where:
•facility is the AID facility
|
Example
|
Input
RMV-EC1:CISCO:FAC-1-1:1234;
|
Errors
|
This message generates all the default errors
|
11.11.60 RST-<MOD2>: Restore (DS1, EC1,OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command provisions a facility in service.
Section
|
Description
|
Category
|
Facility
|
Security
|
N/A
|
Related Messages
|
N/A
|
Input Format
|
RST-<MOD2>:[TID]:<facility>:[CTAG];
where:
•facility is the AID facility
|
Example
|
Input
RST-EC1:CISCO:FAC-1-1:1234;
|
Errors
|
This message generates all the default errors
|
11.11.61 RTRV-<OCN_TYPE>: Retrieve (OC3, OC12, OC48)
This command retrieves the parameters of an OC-N facility.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-<OCN_TYPE>:[TID]:<fac_aid>:[CTAG]::::;
where:
•fac_aid is the AID facility and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<fac_aid>:[SDCC=<sdcc>],[TMERGF=<tmgref>],[SPNWTR=<spnwtr>], [PJMON=<pjmon>],[SFBER=<sfber>],[SDBER=<sdber>], [MODE=<mode>],[WVLEN=<wvlen>]:<pst>,,<role>,<status>" ;
where:
•fac_aid is the AID facility
•sdcc is of type SDCC_MODE and is optional
•tmgref is of type TMG_REF and is optional
•spnwtr is of type REVERTIVE_TIME and is optional
•pjmon is an Integer and is optional
•sfber is of type SF_BER and is optional
•sdber is of type SD_BER and is optional
•mode is of type OPTICAL-MODE. mode is optional
•wvlen is the optical signal wavelength in nanometers; it is a Float and is optional
•pst is of type PST
•role is of type SIDE
•status is of type STATUS
|
Example
|
Input
RTRV-OC3:CISCO:FAC-15-2:123::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-15-2:SDCC=N, TMGREF=N, SPNWTR=8.5, PJMON=0, SFBER=1E-4, SDBER=1E-7, MODE=SONET, WVLEN=1310.00:OOS,, WORK,STBY" ;
|
Errors
|
This message generates all the default errors
|
11.11.62 RTRV-<STS_PATH>: Retrieve (STS1, STS3C, STS12C)
This command retrieves the attributes associated with an STS path.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-<STS_PATH>:[TID]:<sts_aid>:[CTAG]::::;
where:
•sts_aid is the AID sts and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<sts_aid>:RATE=<stsrate>,[SFBER=<sfber>],[SDBER=<sdber>]" ;
where:
•sts_aid is the AID sts
•stsrate is the STS Rate and is of type STS_PATH
•sfber is of type SF_BER and is optional
•sdber is of type SD_BER and is optional
|
Example
|
Input
RTRV-STS1:FERNDALE:STS-2-4:238::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "STS-2-4:RATE=STS1,SFBER=1E-3,SDBER=1E-5" ;
|
Errors
|
This message generates all the default errors
|
11.11.63 RTRV-ALM-<MOD2ALM>:Retrieve Alarm (DS1, E100, E1000, EC1, OC12, OC3, OC48, STS1, STS12C, STS3C, STS48C, T1, T3, VT1)
Instructs the network to retrieve and send the current status of its alarm conditions. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM BITS RTRV-ALM-ENV
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-ALL RTRV-COND-SYNCN
|
Input Format
|
RTRV-ALM-<MOD2ALM>:[TID]:<aid>:[CTAG]::[<ntfcncde>],[<condition>], [<serv_eff>],,,;
where:
•aid is the AID facility and must not be null
•ntfcnde is the 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"
•condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"
•serveff of type SERV_EFF and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<aid>,<type>:<ntfcnde>,<condition>,<srveff>,,,,:<desc>" ;
where:
•aid is the AID facility
•type specifies the type of OC-N facility associated with the facility AID; type is of type MOD2ALM
•ntfcnde is the 2-letter notification code and is of type NOTIF_CODE
•condition is a type of alarm condition and is of type CONDITION
•srveff is the type of effect on service caused by the alarm condition and is of type SERV_EFF
•desc is a String
|
Example
|
Input
RTRV-ALM-OC12:ELDRIDGE:FAC-6-1:255::MN,SD,SA,,,;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-6-1,OC12:MJ,SD,SA,,,,:\"BER AT SIGNAL DEGRADE LEVEL\"," ;
|
Errors
|
This message generates all the default errors
|
11.11.64 RTRV-ALM-ALL: Retrieve Alarm All
This command instructs the NE to retrieve and send the current status of all active alarm conditions. The alarm condition or severity retrieved is specified using the input parameters as a filter.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM BITS RTRV-ALM-ENV
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-ALM-ALL:[TID]::[CTAG]::,,,,,;
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<aid>,<aid_type>:<notifCode>,<condition1>,<servEff>,,,,,:<dnField>" ;
where:
•aid is the aid where the alarm took place and d is the AID ALL
•aid_type is of type MOD2
•notifCode is of type NOTIF_CODE
•condition1 is of type CONDITION
•servEff is a service-affecting alarm and is of type SERV_EFF
•dsField is a String
|
Example
|
Input
RTRV-ALM-ALL:COTATI::229::,,,,,;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-2,EQPT:MN,PWRRESTART,NSA,,,,,:\"POWERFAIL RESTART\"," ;
|
Errors
|
This message generates all the default errors
|
11.11.65 RTRV-ALM-BITS: Retrieve Alarm Building Integrated Timing Supply
This command instructs the NE to retrieve and send the current status of its alarm conditions associated with the BITS facility. The alarm condition or severity retrieved is specified using the input parameters as a filter.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-ALL
REPT ALM BITS RTRV-ALM-ENV
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-ALM-BITS:[TID]:<bits_aid>:[CTAG]::[<ntfcncde>],[<condition>], [<serv_eff>];
where:
•bits_aid is the AID bits and must not be null.
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"
•condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"
•serv_eff is a type of effect on service caused by the alarm condition and is of type SERV_EFF; a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<bits_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>" ;
where:
•bits_aid is the AID bits
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE
•condition is a type of alarm condition and is of type CONDITION
•srveff is a type of effect on service caused by the alarm condition and is of type SERV_EFF
•desc is a String
|
Example
|
Input
RTRV-ALM-BITS:ELVERANO:BITS-1:288::CR,LOS,SA;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "BITS-1:CR,LOS,SA,,,,:\"LOSS OF SIGNAL\"," ;
|
Errors
|
This message generates all the default errors
|
11.11.66 RTRV-ALM-ENV: Retrieve Alarm Environment
This command instructs the NE to retrieve outstanding environmental alarms.
Section
|
Description
|
Category
|
Environment
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-ALL
REPT ALM BITS RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-ALM-ENV:[TID]:[<env>]:[CTAG]::[<notifCode>],[<envAlm>];
where:
•env is the AID env and is listable; a null value is equivalent to "ALL"
•notifCode is of type NOTIF_CODE and a null value is equivalent to "ALL"
•envAlm is of type ENV_ALM and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<env>:<notifCode>,<envAlm>,,,[<desc>]" ;
where:
•env is the AID env
•notifCode is of type NOTIF_CODE
•envAlm is of type ENV_ALM
•desc is a String
|
Example
|
Input
RTRV-ALM-ENV:CISCO-1:ENV-IN-1:123::MJ,OPENDR;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "ENV-IN-1:MJ,OPENDR,,,\"OPEN DOOR\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.67 RTRV-ALM-EQPT: Retrieve Alarm Equipment
This command instructs the NE to retrieve and send the current status of its equipment-unit alarm conditions. The alarm condition or severity retrieved is specified using the input parameters as a filter.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-<MOD2ALM>
ED-FFP-EQPT RTRV-ALM-ALL
ENT-EQPT RTRV-ALM-BITS
ENT-FFP-EQPT RTRV-ALM-ENV
OPR-PROTNSW-EQPT RTRV-ALM-SYNCN
REPT ALM <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT ALM BITS RTRV-COND-ALL
REPT ALM ENV RTRV-COND-BITS
REPT ALM EQPT RTRV-COND-EQPT
REPT ALM SYNCN RTRV-COND-SYNCN
REPT EVT <MOD2ALM> RTRV-EQPT
REPT EVT EQPT RTRV-FFP-EQPT
REPT EVT SYNCN SW-DX-EQPT
|
Input Format
|
RTRV-ALM-EQPT:[TID]:<eqpt_aid>:[CTAG]::[<ntfcncde>],[<condition>], [<serv_eff>],,,;
where:
•eqpt_aid is the AID eqpt and must not be null
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"
•condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"
•serv_eff is of type SERV_EFF and is null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<eqpt>,<eqpt_type>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>" ;
where:
•eqpt is the AID eqpt
•eqpt_type specifies the type of card associated with the slot AID for equipment units; eqpt_type is of type EQPT_TYPE
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE
•condition is a type of alarm condition and is of type CONDITION
•srveff is a type of effect on service caused by the alarm condition; srveff is of type SERV_EFF
•desc is a String
|
Example
|
Input
RTRV-ALM-EQPT:TWOROCK:SLOT-7:227::MJ,HITEMP,NSA,,,;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-7,TCC:MJ,HITEMP,NSA,,,,:\"HIGH TEMPERATURE\"," ;
|
Errors
|
This message generates all the default errors
|
11.11.68 RTRV-ALM-SYNCN: Retrieve Alarm Synchronization
Instructs the NE to retrieve and send the current status of its alarm conditions associated with a synchronization facility. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read Only
|
Related Messages
|
ED-SYNCN RTRV-ALM-ALL
OPR-SYNCNSW RTRV-ALM-BITS
REPT ALM <MOD2ALM> RTRV-ALM-ENV
REPT ALM BITS RTRV-ALM-EQPT
REPT ALM ENV RTRV-COND-<MOD2ALM>
REPT ALM EQPT RTRV-COND-ALL
REPT ALM SYNCN RTRV-COND-BITS
REPT EVT <MOD2ALM> RTRV-COND-EQPT
REPT EVT EQPT RTRV-COND-SYNCN
REPT EVT SYNCN RTRV-SYNCN
RTRV-ALM-<MOD2ALM>
|
Input Format
|
RTRV-ALM-SYNCN:[TID]:[<sync_aid>]:[CTAG]::[<ntfcncde>],[<condition>], [<serv_eff>];
where:
•sync_aid is the AID sync_ref and is listable; a null value is equivalent to "ALL"
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE; a null value is equivalent to "ALL"
•condition is a type of alarm condition and is of type CONDITION; condition is listable and a null value is equivalent to "ALL"
•serv_eff is a type of effect on service caused by the alarm condition; serv_eff is of type SERV_EFF and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<sync_aid>:<ntfcncde>,<condition>,<srveff>,,,,:<desc>" ;
where:
•sync_aid identifies the facility queried and is the AID sync_ref
•ntfcncde is a 2-letter notification code and is of type NOTIF_CODE
•condition is a type of alarm condition and is of type CONDITION
•srveff is a type of effect on service caused by the alarm condition; serveff is of type SERV_EFF
•desc is a String
|
Example
|
Input
RTRV-ALM-SYNCN:FULTON:SYNC-NE:226::CR,FAILTOSW,SA;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SYNC-NE:CR,FAILTOSW,SA,,,,:\"FAILURE TO SWITCH TO PROTECTION\"," ;
|
Errors
|
This message generates all the default errors
|
11.11.69 RTRV-BITS: Retrieve Building Integrated Timing Supply
This command retrieves the BITS configuration command.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-BITS:[TID]:<bits_aid>:[CTAG]::::;
where:
•bits_aid is the AID bits and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<bits_aid>:LNCDE=<line_code>,FMT=<frame_format>:<pst>" ;
where:
•bits_aid is the AID bits
•line_code is of type LINE_CODE
•frame_format is of type FRAME_FORMAT
•pst is of type PST
|
Example
|
Input
RTRV-BITS:SONOMA:BITS-1:782::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "BITS-1:LNCDE=AMI,FMT=ESF:IS" ;
|
Errors
|
This message generates all the default errors
|
11.11.70 RTRV-COND-<MOD2ALM>: Retrieve Condition (DS1, E100, E1000, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command instructs the NE to retrieve the current standing condition and/or state associated with an entity.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-ALL
REPT ALM BITS RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-ENV
REPT ALM EQPT RTRV-ALM-EQPT
REPT ALM SYNCN RTRV-ALM-SYNCN
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-COND-<MOD2ALM>:[TID]:[<facility>]:[CTAG]::[<condition>],,,;
where:
•facility is the facility aid and is the AID facility; a null value is equivalent to "ALL"
•condition is the requested condition, if not set=> we want all the conditions for the specified facility; condition is of type CONDITION and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>,<eqptType>:[<notifcode>],<condition>,[<servEff>],,,,,, [<desc>]" ;
where:
•facility is the facility aid and is the AID facility
•eqptType is of type EQPT_TYPE
•notifCode is the notification code; notifCode is of type NOTIF_CODE and is optional
•condition is the condition itself and is of type CONDITION
•servEff is of type SERV_EFF and is optional
•desc is the condition description; desc is a String and is optional
|
Example
|
Input
RTRV-COND-T3:TID:FAC-2-1:229::LOS,,,;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-2-1,DS3-12:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.71 RTRV-COND-ALL: Retrieve Condition All
This command instructs the NE to retrieve the current standing condition for all entities.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-ALL
REPT ALM BITS RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-ENV
REPT ALM EQPT RTRV-ALM-EQPT
REPT ALM SYNCN RTRV-ALM-SYNCN
REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-COND-ALL:[TID]::[CTAG]::[<condition>],::;
where:
•condition is of type CONDITION and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>,[<aid_type>]:[<notifCode>],<condition>,[<servEff>],,,,,, [<desc>]" ;
where:
•facility is the AID facility
•aid_type is of type MOD2B and is optional
•notifCode is of type NOTIF_CODE and is optional
•condition is of type CONDITION
•servEff is of type SERV_EFF and is optional
•desc is a String and is optional
|
Example
|
Input
RTRV-COND-ALL::TID::229::LOS,,,:
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-2-1,OC3:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.72 RTRV-COND-BITS: Retrieve Condition Building Integrated Timing Supply
This command instructs the NE to retrieve the standing conditions on BITS.
Section
|
Description
|
Category
|
Fault
|
Security
|
Read Only
|
Related Messages
|
REPT ALM <MOD2ALM> RTRV-ALM-ALL
REPT ALM BITS RTRV-ALM-BITS
REPT ALM ENV RTRV-ALM-ENV
REPT ALM EQPT RTRV-ALM-EQPT
REPT ALM SYNCN RTRV-ALM-SYNCN
REPT EVT <MOD2ALM> RTRV-COND-<MOD2ALM>
REPT EVT EQPT RTRV-COND-ALL
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2ALM> RTRV-COND-SYNCN
|
Input Format
|
RTRV-COND-BITS:[TID]:<facility>:[CTAG]::[<condition>],,,;
where:
•facility is the AID bits and must not be null
•condition is of type CONDITION and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>,<eqptType>:[<notifCode>],<condition>,[<servEff>],,,,,, [<desc>]" ;
where:
•facility is the AID bits
•eqptType is of type EQPT_TYPE
•notifCode is of type NOTIF_CODE and is optional
•condition is of type CONDITION
•servEff is of type SERV_EFF and is optional
•desc is a String and is optional
|
Example
|
Input
RTRV-COND-BITS:TID:BITS-1:229::LOS,,,:
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "BITS-1,TCC:CR,LOS,SA,,,,,,\"LOS OF SIGNAL\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.73 RTRV-COND-EQPT: Retrieve Condition Equipment
This command instructs the NE to retrieve current equipment conditions.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT RLS-PROTNSW-EQPT
DLT-FFP-EQPT RTRV-ALM-<MOD2ALM>
ED-FFP-EQPT RTRV-ALM-ALL
ENT-EQPT RTRV-ALM-BITS
ENT-FFP-EQPT RTRV-ALM-ENV
OPR-PROTNSW-EQPT RTRV-ALM-EQPT
REPT ALM <MOD2ALM> RTRV-ALM-SYNCN
REPT ALM BITS RTRV-COND-<MOD2ALM>
REPT ALM ENV RTRV-COND-ALL
REPT ALM EQPT RTRV-COND-BITS
REPT ALM SYNCN RTRV-COND-SYNCN
REPT EVT <MOD2ALM> RTRV-EQPT
REPT EVT EQPT RTRV-FFP-EQPT
REPT EVT SYNCN SW-DX-EQPT
|
Input Format
|
RTRV-COND-EQPT:[TID]:<facility>:[CTAG]::[<condition>],,,;
where:
•facility is the AID and must not be null.
•condition is of type CONDITION and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME
M CTAG COMPLD
"<facility>,<eqptType>:[<notifCode>],<condition>,[<servEff>],,,,,,[<desc>]"
;
where:
•facility is the AID facility
•eqptType is of type EQPT_TYPE
•notifCode is of type NOTIF_CODE and is optional
•condition is of type CONDITION
•servEff is of type SERV_EFF and is optional
•desc is a String and is optional
|
Example
|
Input
RTRV-COND-EQPT:TID:SLOT-1:229::LOS,,,:
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-1,DS3-12:CR,LOS,SA,,,,,,,\"LOS OF SIGNAL\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.74 RTRV-COND-SYNCN: Retrieve Condition Synchronization
This command retrieves the synchronization condition.
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read Only
|
Related Messages
|
ED-SYNCN RTRV-ALM-ALL
REPT ALM <MOD2ALM> RTRV-ALM-BITS
REPT ALM BITS RTRV-ALM-ENV
REPT ALM ENV RTRV-ALM-EQPT
REPT ALM EQPT RTRV-ALM-SYNCN
REPT ALM SYNCN RTRV-COND-<MOD2ALM>
REPT EVT <MOD2ALM> RTRV-COND-ALL
REPT EVT EQPT RTRV-COND-BITS
REPT EVT SYNCN RTRV-COND-EQPT
RTRV-ALM-<MOD2> RTRV-SYNCN
|
Input Format
|
RTRV-COND-SYNCN:[TID]:<facility>:[CTAG]::[<condition>],,,;
where:
•facility is the AID sync_ref and must not be null
•condition is of type CONDITION and a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>,[<eqptType>]:[<notifCode>],<condition>,[<servEff>],,,,,, [<desc>]" ;
where:
•facility is the AID sync_ref
•eqptType is of type EQPT_TYPE and is optional
•notifCode is of type NOTIF_CODE and is optional
•condition is of type CONDITION
•servEff is of type SERV_EFF and is optional
•desc is a String and is optional
|
Example
|
Input
RTRV-COND-SYNCN:TID:SYNC-NE:229::LOS,,,:
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SYNC-NE,TCC:MJ,FRNGSYNC,SA,,,,,,\"FREE RUNNING SYNCHRONIZAION MODE\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.75 RTRV-CRS-<STS_PATH>: Retrieve Cross Connect (STS1, STS3C STS12C)
This command retrieves any connections associated with the Access Identifiers entered. FROM and TO information is returned along with the type of connection.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Read Only
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-VT1
|
Input Format
|
RTRV-CRS-<STS_PATH>:[TID]:<sts_ep>:[CTAG]::,,,;
where:
•sts_ep is the AID sts and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<crs_ep>,<crs_ep1>:<cct>" ;
where:
•crs_ep is the AID sts
•crs_ep1 is the AID sts
•cct is the cross connect type and is of type CCT
|
Example
|
Input
RTRV-CRS-STS3C:KENWOOD:STS-6-1:223::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "STS-6-1,STS-12-4:2WAY" ;
|
Errors
|
This message generates all the default errors
|
11.11.76 RTRV-CRS-VT1: Retrieve Cross Connect Virtual Tributary
This command retrieves the VT cross-connection information.
Section
|
Description
|
Category
|
Cross Connect
|
Security
|
Read Only
|
Related Messages
|
DLT-CRS-<STS_PATH>
DLT-CRS-VT1
ED-CRS-<STS_PATH>
ED-CRS-VT1
ENT-CRS-<STS_PATH>
ENT-CRS-VT1
RTRV-CRS-<STS_PATH>
|
Input Format
|
RTRV-CRS-VT1:[TID]:<vt>:[CTAG]::::;
where:
•vt is the AID vt1_5 and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<from>,<to>:<cct>" ;
where:
•from is the first (FROM) VT in cross-connection and is the AID vt1_5
•to is the second (TO) VT in cross-connection and is the AID vt1_5
•cct is the cross connect type and is of type CCT
|
Example
|
Input
RTRV-CRS-VT1:CISCO:VT1-2-3-1:1234::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "VT1-2-3-1,VT1-4-4-1:1WAY" ;
|
Errors
|
This message generates all the default errors
|
11.11.77 RTRV-EC1: Retrieve Electrical Carrier Level 1
This command retrieves the facility status of an EC-1 card.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-EC1:[TID]:<fac>:[CTAG]::::;
where:
•fac is the facility aid and is the AID facility; fac must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<fac>:PJMON=<pjmon>,LBO=<lbo>:PST=<pst>" ;
where:
•fac is the facility aid and is the AID facility
•pjmon is the SONET pointer monitor and is an Integer
•lbo is line buildout and is of type E_LBO
•pst is the primary service state and is of type PST
|
Example
|
Input
RTRV-EC1:CISCO:FAC-1-1:1234::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-1-1:PJMON=0,LBO=0-225:PST=IS" ;
|
Errors
|
This message generates all the default errors
|
11.11.78 RTRV-EQPT: Retrieve Equipment
This command retrieves the data and state parameters associated with an equipment unit.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT REPT EVT EQPT
DLT-FFP-EQPT RLS-PROTNSW-EQPT
ED-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-FFP-EQPT
OPR-PROTNSW-EQPT SW-DX-EQPT
REPT ALM EQPT
|
Input Format
|
RTRV-EQPT:[TID]:<eqpt_aid>:[CTAG]::::;
where:
•eqpt_aid is the AID eqpt and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<eqpt_aid>:[<eqpt_type>]:[WTR=<wtr>],[NAME=<name>]:<state>, <equip>,[<role>],[<status>]" ;
where:
•eqpt_aid is the AID eqpt
•eqpt_type is the type of card in the slot; eqpt_type is of type EQPT_TYPE and is optional
•wtr is an Integer and is optional
•name is a String and is optional
•state is of type PST
•equip indicates if the equipment unit is physically present and is of type EQUIP.
•role indicates if the card is a working unit or the protecting unit; role is of type SIDE and is optional
•status is of type STATUS and is optional
|
Example
|
Input
RTRV-EQPT:MIRABEL:SLOT-12:230::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-12:OC12:WTR=99,NAME=DESCRIPTION:IS,EQUIP,,ACT" ;
|
Errors
|
This message generates all the default errors
|
11.11.79 RTRV-FFP-<OCN_TYPE>: Retrieve Facilities Protection Group (OC3, OC12, OC48)
This command retrieves the optical facility protection information.
Section
|
Description
|
Category
|
Facility Protection
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-FFP-<OCN_TYPE>:[TID]:<facility>:[CTAG];
where:
•facility is the AID facility and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<work>,<protect>:NAME=<name>,RVTT=<revertiveType>, RVTM=<revertiveTime>,BSWM=<bswMode>" ;
where:
•work is the AID facility
•protect is the AID facility
•name is the protection name and is a String
•revertiveType is the revertive type and e is of type REVERTIVE_TYPE
•revertiveTime is the revertive time and is of type REVERTIVE_TIME
•bswMode specifies if it is a bidirectional switch mode and is of type ON_OFF
|
Example
|
Input
RTRV-FFP-OC3:PETALUMA:FAC-3-1:1;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-3-1,FAC-4-1:NAME=PROT_NAME,RVTT=R,RVTM=1.0, BSWM=OFF" ;
|
Errors
|
This message generates all the default errors
|
11.11.80 RTRV-FFP-EQPT: Retrieve Facilities Protection Group Equipment
This command retrieves the equipment protection information.
Section
|
Description
|
Category
|
Equipment
|
Security
|
Read Only
|
Related Messages
|
DLT-EQPT REPT EVT EQPT
DLT-FFP-EQPT RLS-PROTNSW-EQPT
ED-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT SW-DX-EQPT
REPT ALM EQPT
|
Input Format
|
RTRV-FFP-EQPT:[TID]:<eqpt>:[CTAG];
where:
•eqpt is the AID eqpt and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<work>,<protect>:PRT=<protectionGroup>,NAME=<name>, RVTT=<revertiveType>,RVTM=<revertiveTime>,BSWM=<bswMode>" ;
where:
•work is the working slot aid and is the AID eqpt
•protect is the protection slot aid and is the AID eqpt
•protectionGroup is the protection group and is of type PROTECTION_GROUP
•name is the protection name and is a String
•revertiveType is of type REVERTIVE_TYPE
•revertiveTime is of type REVERTIVE_TIME
|
Example
|
Input
RTRV-FFP-EQPT:PETALUMA:SLOT-16:1;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-16,SLOT-17:PRT=1-1,NAME=PROT_NAME,RVTT=R,RVTM=1.0" ;
|
Errors
|
This message generates all the default errors
|
11.11.81 RTRV-HDR: Retrieve Header
This command instructs the NE to return the header of a TL1 response message. Used by TL1 clients to determine if the link to the NE is still active and if the NE is responding to commands.
Section
|
Description
|
Category
|
System
|
Security
|
Read Only
|
Related Messages
|
ACT-USER
ALW-MSG-ALL
CANC-USER
ED-DAT
INH-MSG-ALL
INIT-SYS
|
Input Format
|
RTRV-HDR:[TID]::[CTAG];
|
Example
|
Input
RTRV-HDR:SONOMA::232;
|
Errors
|
This message generates all the default errors
|
11.11.82 RTRV-INV: Retrieve Inventory
This command queries the NE and returns a listing of the equipment inventory. For each unit in the system, it identifies the unit's hardware version and revision numbers, firmware version, and the unit's CLEI code.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-INV:[TID]:<eqpt_aid>:[CTAG]::,,;
where:
eqpt_aid is the AID eqpt and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<eqpt_aid>,<eqptType>:[PN=<pn>],[HWVER=<hwver>], [FWVER=<fwver>],[SN=<sn>],[CLEI=<clei>]" ;
where:
•eqpt_aid is the AID eqpt
• eqpt_type is of type EQPT_TYPE
•pn is a String and is optional
•hwver is a String and is optional
•fwver is a String and is optional
•sn is an integer and is optional
•clei is a String and is optional
|
Example
|
Input
RTRV-INV:OCCIDENTAL:SLOT-15:301::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SLOT-15,OC3-IR-4:PN=87-00002,HWVER=004K, FWVER=76-99-00009-004A,SN=013510,CLEI=NOCLEI" ;
|
Errors
|
This message generates all the default errors
|
11.11.83 RTRV-LOG: Retrieve Log
This command retrieves the alarm log of the NE.
Section
|
Description
|
Category
|
Log
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-LOG:[TID]::[CTAG];
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<aid>,<seq>:CURRENT=<current>,[PREVIOUS=<previous>], <condition>,servEff>,[TIME=<time>],DATE=<date>:<desc>" ;
where:
•aid is the AID ALL
•seq is an Integer
•current is of type NOTIF_CODE
•previous is of type COND_EFF and is optional
•condition is of type CONDITION
•servEff is of type SERV_EFF
•time is a Date and is optional
•date is a String
•desc is a String
|
Example
|
Input
RTRV-LOG:CISCO::123;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-3-1,12:CURRENT=MJ,PREVIOUS=CL,EOC,NSA,TIME=16-33-04, DATE=1971-02-03:\"SDCC TERMINATION FAILURE\"" ;
|
Errors
|
This message generates all the default errors
|
11.11.84 RTRV-NE: Retrieve Network Element
This command retrieves the attributes of the NE system such as the node identity (e.g. IP address), external interfaces (e.g. LAN ports), and major modes of operation (e.g. SONET vs. SDH).
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-NE:[TID]::[CTAG]::::;
|
Output Format
|
SID DATE TIME M CTAG COMPLD "IPADDR=<ipaddr>,IPMASK=<ipmask>,DEFRTR=<defrtr>, EXTLAN=<extlan>,INTLAN=<intlan>,RTRMDE=<rtrmode>, STM=<stm>,NODEID=<nodeid>,EXTRNG=<ext_ring>, RNGWTR=<rngwtr>,TMMD=<timing_mode>,SSMG=<sync_gen>, NSQL=<sync_quality_level>" ;
where:
•ipaddr is the IP address of the NE on the local LAN and is a String
•ipmask is the IP Mask used to identify the sub-net on which the NE resides; ipmask is a String
•defrtr is the IP address of the default router and is a String
•extlan is of type EXT_LAN
•intlan is of type EXT_LAN
•rtrmode is of type EXT_LAN
•stm is of type OPTICAL_MODE
•nodeid is the Node ID of the NE in the BLSR and is an Integer
•ext_ring is the node/ring that supports the extended K1/K2/K3 protocol for more than 16 nodes per BLSR; ext_ring is of type EXT_RING
•rngwtr is an Integer
•timing_mode is of type TIMING_MODE
•sync_gen is of type SYNC_GENERATION
•sync_quality_level is of type SYNC_QUALITY_LEVEL
|
Example
|
Input
RTRV-NE:LAKEVILLE::233::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "IPADDR=192.168.100.52,IPMASK=255.255.255.0, DEFRTR=192.168.100.1,EXTLAN=OFF,INTLAN=OFF, RTRMDE=OFF,STM=SONET,NODEID=3,EXTRNG=N,RNGWTR=99, TMMD=LINE,SSMG=GEN1,NSQL=ABOVE-PRS"
;
|
Errors
|
This message generates all the default errors
|
11.11.85 RTRV-PM-<MOD2>: Retrieve Performance (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command retrieves the performance monitoring for specified card type.
Note Release 2.2.1 does not support the 48C value.
Section
|
Description
|
Category
|
Performance
|
Security
|
Read Only
|
Related Messages
|
INIT-REG-<MOD2>
RTRV-TH-<MOD2>
SET-TH-<MOD2>
|
Input Format
|
RTRV-PM-<MOD2>:[TID]:<aid>:[CTAG]::,,,,<tmpr>,,;
where:
•aid is the AID ALL and must not be null
•tmpr is of type TMPR and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<aid>:<montype>,<monval>,<validity>,<location>,<tmpr>,<direction>" ;
where:
•aid is the AID ALL
•montype is the monitored type ex CVL, ESL and is of type ALL_MONTYPE
•monval is the monitored value and l is an Integer
•validity is of type VALIDITY
•location is the location far-end, near-end or both; location is of type LOCATION
•tmpr is the time period 15 min, 1 hour or 1 day; tmpr is of type TMPR
•direction is the direction receive, transmit or both; direction is of type DIRECTION
|
Example
|
Input
RTRV-PM-T1:TID:AID:123::,,,,15MIN,,;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "AID:CVL,21,COMPL,FEND,15MIN,RCV,," ;
|
Errors
|
This message generates all the default errors
|
11.11.86 RTRV-SYNCN: Retrieve SYNCN
This command retrieves the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources may be specified (e.g. PRIMARY, SECOND,THIRD).
Section
|
Description
|
Category
|
Synchronization
|
Security
|
Read Only
|
Related Messages
|
ED-SYNCN
OPR-SYNCNCSW
REPT ALM SYNCN
REPT EVT SYNCN
RTRV-ALM-SYNCN
RTRV-COND-SYNCN
|
Input Format
|
RTRV-SYNCN:[TID]:<sync_aid>:[CTAG]::::;
where:
•sync_aid identifies the synchronization reference to retrieve and is the AID sync_ref; sync_ref is listable and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<sync_aid>:PRIMARY=<primary>,SECOND=<second>,THIRD=<third>" ;
where:
•sync_aid is the synchronization reference to be modified and is the AID sync_ref
•primary is the AID syn_src
•second is the AID syn_src
•third is the AID syn_src
|
Example
|
Input
RTRV-SYNCN:BOYES:SYNC-NE:234::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "SYNC-NE:PRIMARY=FAC-1-2,SECOND=FAC-2-2,THIRD=FAC-3-2;" ;
|
Errors
|
This message generates all the default errors
|
11.11.87 RTRV-T1: Retrieve T1
This command retrieves the DS-1 facilities configuration.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
ED-T1
ED-T3
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-T1
RLS-LPBK-T3
RTRV-T3
|
Input Format
|
RTRV-T1:[TID]:<aid>:[CTAG]::::;
where:
•aid is the AID facility and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<aid>:STATE=<pst>,ID=<id>,LNCDE=<line_code>, FRMF=<fame_format>,LBO=<line_buildout>" ;
where:
•aid is the AID facility
•pst is of type PST
•id is a String
•line_code is of type LINE_CODE
•frame_format is of type FRAME_FORMAT
•line_buildout is of type LINE_BUILDOUT
|
Example
|
Input
RTRV-T1:TID:AID:1223::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "AID:STATE=OOS,ID=CISCO,LNCDE=AMI,FRMF=ESF,LBO=0-131" ;
|
Errors
|
This message generates all the default errors
|
11.11.88 RTRV-T3: Retrieve T3
This command retrieves the facilities properties of a DS-3 and a DS-3 transmux card.
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
ED-T1
ED-T3
OPR-LPBK-T1
OPR-LPBK-T3
RLS-LPBK-T1
RLS-LPBK-T3
RTRV-T1
|
Input Format
|
RTRV-T3:[TID]:<facility>:[CTAG]::::;
where:
•facility is the facility aid FAC-[SLOT]-[1..6] or FAC-[SLOT]-[1..12]; facility is the AID facility and must not be null
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>:LNTYPE=<lineType>,[LNCODE=<lineCode>],LBO=<lbo>: PST=<pst>" ;
where:
•facility is the facility aid FAC-[SLOT]-[1..6] or FAC-[SLOT]-[1..12] and is the AID facility.
•lineType is the port line type and is of type DS_LINE_TYPE
•lineCode is the port one code; lineCode is of type DS_LINE_CODE and is optional
•lbo is the circuit line buildout and is of type E_LBO
•pst is of type PST
|
Example
|
Input
RTRV-T3:CISCO:FAC-1-2:123::::;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-1-2:LNTYPE=C-BIT,LNCODE=B3ZS,LBO=0-225:PST=IS" ;
|
Errors
|
This message generates all the default errors
|
11.11.89 RTRV-TH-<MOD2>: Retrieve Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command retrieves the threshold level.
Note Release 2.2.1 does not support STS48C and VT1.
Section
|
Description
|
Category
|
Performance
|
Security
|
Read Only
|
Related Messages
|
INIT-REG-<MOD2>
RTRV-PM-<MOD2>
SET-TH-<MOD2>
|
Input Format
|
RTRV-TH-<MOD2>:[TID]:<facility>:[CTAG]::<allMontype>,[<location>], [<tmpr>];
where:
•facility is the aid type and is the AID ALL; facility must not be null
•allMontype is the monitored type and is of type ALL_MONTYPE; allMontype must not be null
•location is the location and is of type LOCATION; a null value is equivalent to "ALL"
•tmpr is the time period and is of type TMPR; a null value is equivalent to "ALL"
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<facility>,[<eqptType>]:<allMontype>,[<location>],,<thval>,[<tmpr>]" ;
where:
•facility is the aid and is the AID ALL
•eqptType is of type EQPT_TYPE and is optional
•allMontype is the monitored type and is of type ALL_MONTYPE
•location is the location and is of type location; location is optional
•thVal is the threshold value and is an Integer
•tmpr is the time period and is of type TMPR; tmpr is optional
|
Example
|
Input
RTRV-TH-T3:CISCO:FAC-1-3:1234::CVL,FEND,15MIN;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "FAC-1-3,DS3-12:CVL,FEND,,1,15MIN" ;
|
Errors
|
This message generates all the default errors
|
11.11.90 RTRV-TOD: Retrieve Time of Day
This command queries the NE and displays the system date and time at the instant when the command was executed. The time returned is in Coordinated Universal Time (UTC).
Section
|
Description
|
Category
|
Other
|
Security
|
Read Only
|
Related Messages
|
N/A
|
Input Format
|
RTRV-TOD:[TID]::[CTAG];
|
Output Format
|
SID DATE TIME M CTAG COMPLD "<year>,<month>,<day>,<hour>,<minute>,<second>,,<tmtype>" ;
where:
•year is an Integer
•month is an Integer
•day is an Integer
•hour is an Integer
•minute is an Integer
•second is an Integer
•tmtype is a String
|
Example
|
Input
RTRV-TOD:CAZADERO::230;
Output
TID-000 98-06-20 14-30-00 M 001 COMPLD "1998,05,08,17,01,33,,UTC" ;
|
Errors
|
This message generates all the default errors
|
11.11.91 SET-TH-<MOD2>: Set Threshold (DS1, EC1, OC3, OC12, OC48, STS1, STS3C, STS12C, STS48C, T1, T3, VT1)
This command sets the threshold level.
Note Release 2.2.1 does not support STS48C.
Section
|
Description
|
Category
|
Performance
|
Security
|
Read/Write
|
Related Messages
|
INIT-REG-<MOD2>
RTRV-TH-<MOD2>
RTRV-PM-<MOD2>
|
Input Format
|
SET-TH-<MOD2>:[TID]:<facility>:[CTAG]::<allMontype>,<thVal>, [<location>],,[<tmpr>];
where:
•facility is the aid and is the AID ALL
•allMontype is the monitored value and is of type ALL_MONTYPE
•thVal is the threshold value and is an Integer
•location is the location and is of type LOCATION
•tmpr is the time period and is of type TMPR
|
Example
|
Input
SET-TH-T3:CISCO:FAC-1-1:123::CVL,12,NEND,,15MIN;
|
Errors
|
This message generates all the default errors
|
11.11.92 SET-TOD: Set Time of Day
This command sets the system date and time for the NE. The year should be entered using four digits while the hour should be entered using a 24-hour time period (i.e. military time).
Section
|
Description
|
Category
|
Other
|
Security
|
Read/Write
|
Related Messages
|
N/A
|
Input Format
|
SET-TOD:[TID]::[CTAG]::<year>,<month>,<day>,<hour>,<minute>,<second>,[<difference>]:[USEDST=<usedst>];
where:
•year is the current calendar year and is an Integer
•month is the month of the year and ranges from 01 to 12; month is an Integer
•day is the day of the month and ranges from 01 to 31; day is an Integer
•hour is the hour of the day and ranges from 00 to 59; hour is an Integer
•minute is the minute of the hour and ranges from 00 to 59; minute is an Integer
•second is the second of the minute and ranges from 00 to 59; second is an Integer
•difference is the number of minutes behind UTC and is an Integer
•usedst indicates if Daylight Saving Time is used and is of type USE_DST
|
Example
|
Input
SET-TOD:CAZADERO::240::1998,05,08,13,18,55,480:USEDST=Y;
|
Errors
|
This message generates all the default errors
|
11.11.93 SW-DX-EQPT: Switch DX Equipment
This command instructs the NE to switch duplex equipment.
Section
|
Description
|
Category
|
Equipment
|
Security
|
N/A
|
Related Messages
|
DLT-EQPT REPT EVT EQPT
DLT-FFP-EQPT RLS-PROTNSW-EQPT
ED-FFP-EQPT RTRV-ALM-EQPT
ENT-EQPT RTRV-COND-EQPT
ENT-FFP-EQPT RTRV-EQPT
OPR-PROTNSW-EQPT RTRV-FFP-EQPT
REPT ALM EQPT
|
Input Format
|
SW-DX-EQPT:[TID]:<eqpt>:[CTAG]::[<dxModeOp>],;
where:
•eqpt is the AID eqpt
•dxModeOp is of type DX_MODE_OP
|
Example
|
Input
SW-DX-EQPT:CISCO:SLOT-1:123::FRCD,;
|
Errors
|
This message generates all the default errors
|
11.12 Access Identifiers
The Access Identification code (AID) directs an input command to its intended physical or data entity inside the NE. Equipment Modules and facilities are typical examples of entities addressed by the access code.
Table 11-13 Access Identifiers
AID
|
Patterns
|
bits
|
BITS-ALL
BITS-{1,2}
|
ds-1
|
DS1-{1-6,12-17}-{1-6}-{1-28}
|
env
|
ENV-IN-{1-4}
|
eqpt
|
SLOT-{1-17}
SLOT-{1-6,12-17}
|
facility
|
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-{1-12}
FAC-{1-6,12-17}-{1-14}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1-6}
FAC-{5,6,12,13}-1
|
sts
|
STS-{1-6,12-17}-1
STS-{1-6,12-17}-{1,4,7,10-46}
STS-{1-6,12-17}-{1-12}
STS-{1-6,12-17}-{1-6}
STS-{5,6,12,13}-{1,13,25,37}
STS-{5,6,12,13}-{1,4,7,10-46}
STS-{5,6,12,13}-{1-48}
STS-{5,6,12,13}-{1}
|
syn_src
|
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-{1-4}
FAC-{5,6,12,13}-1
INTERNAL
SYNC-NE
SYNC-{BITS1,BITS2}
|
sync_ref
|
SYNC-NE
SYNC-{BITS1,BITS2}
|
vt1_5
|
VT1-{1-6,12-17}-1-{1-14}
VT1-{1-6,12-17}-{1-12}-{1-28}
VT1-{1-6,12-17}-{1-6}-{1-28}
VT1-{5,6,12,13}-{1-48}-{1-28}
|
11.12.1 bits
Table 11-14 bits
Pattern
|
Description
|
BITS-ALL
|
BITS-1 and BITS-2
|
BITS-{1,2}
|
Individual BITS AID
|
11.12.2 ds-1
Used to access the DS-1 frame layer of the DS3XM-6
Table 11-15 ds-1
Pattern
|
Description
|
DS1-{1-6,12-17}-{1-6}-{1-28}
|
DS-1 aid for a DX3Xm card
|
11.12.3 env
The AIC card environmental AIDs
Table 11-16 env
Pattern
|
Description
|
ENV-{IN}-{1-4}
|
Environmental alarm aid
|
11.12.4 eqpt
Table 11-17 eqpt
Pattern
|
Description
|
SLOT-{1-17}
|
Equipment aid for the whole NE
|
SLOT-{1-6,12-17}
|
Equipment aid for the I/O slots
|
11.12.5 facility
Used to access specific ports
Table 11-18 facility
Pattern
|
Description
|
FAC-{1-6,12-17}-1
|
Facility aid for the OC-12
|
FAC-{1-6,12-17}-{1-12}
|
Facility aid for the EC-1 and DS-3 cards
|
FAC-{1-6,12-17}-{1-14}
|
Facilities for the DS-1 card
|
FAC-{1-6,12-17}-{1-4}
|
Facility aid for the OC-3 card
|
FAC-{1-6,12-17}-{1-6}
|
Facility aid for the DS3XM card
|
FAC-{5,6,12,13}-1
|
Facility aid for the OC-48 card
|
.
11.12.6 sts
SONET frame-level AID set
Table 11-19 sts
AID
|
Description
|
STS-{1-6,12-17}-1
|
STS-1 aid for DS-1 cards
STS-3C aid for OC-3 cards
STS-12C aid for OC-12 cards
|
STS-{1-6,12-17}-{1,4,7,10}
|
STS-3C aid for OC-3 and OC-12 cards
|
STS-{1-6,12-17}-{1-12}
|
STS-1 aid for OC-12, EC-1, DS-3 and OC-3 cards
|
STS-{1-6,12-17}-{1-6}
|
STS-1 aid for DS3XM cards
|
STS-{5,6,12,13}-{1,13,25,37}
|
STS-12C for OC-48
|
STS-{5,6,12,13}-{1,4,7,10,13,16,19,22, 25,28,31,34,37,40,43,46}
|
STS-3C for OC-48
|
STS-{5,6,12,13}-{1-48}
|
STS-1 for OC-48
|
STS-{5,6,12,13}-{1}
|
STS-48C for OC-48
|
11.12.7 syn_src
Synchronization source
Table 11-20 sync_src
Pattern
|
Description
|
FAC-{1-6,12-17}-1
|
Sync source is the optical card (OC-12) facility
|
FAC-{1-6,12-17}-{1-4}
|
Sync source is the optical card (OC-3) facility
|
FAC-{5,6,12,13}-1
|
Sync source is the optical card (OC-48) facility
|
INTERNAL
|
Set the syn_src to be the system default value
|
SYNC-NE
|
Sync-NE source
|
SYNC-{BITS1,BITS2}
|
SYNC-BITS1 or SYNC-BITS2 sync source
|
11.12.8 sync_ref
Synchronization aids
Table 11-21 sync_ref
Pattern
|
Description
|
SYNC-NE
|
NE sync aid
|
SYNC-{BITS1,BITS2}
|
BITS1 and BITS2 sync aids
|
11.12.9 vt1_5
Virtual termination aids
Table 11-22 vt1_5
Pattern
|
Description
|
VT1-{1-6,12-17}-1-{1-14}
|
DS-1 vts
|
VT1-{1-6,12-17}-{1-12}-{1-28}
|
OC-12, OC-3, EC-1 vts
|
VT1-{1-6,12-17}-{1-6}-{1-28}
|
DS3XM vts
|
VT1-{5,6,12,13}-{1-48}-{1-28}
|
OC-48 vts
|
11.13 Parameter Types
This section provides a description of all message parameter types defined for the TL1 messages used in the ONS 15454. The TL1 message descriptions frequently refer to this section.
11.13.1 ATAG Description
The Autonomous Message Tag (ATAG) is used for message sequencing. The number is incremented by one for each autonomous message sent by the ONS 15454. The ONS 15454 uses whole numbers 0000 to 9999.
11.13.2 CTAG Description
The Correlation tag is included in each command by the user and is repeated by the ONS 15454 in the response to allow the user to associate the command and response messages.
Note The valid values for a ctag are decimal numbers with a maximum of 6 digits in Release 2.2.1.
11.13.3 TID Description
The Target Identifier is the name of the NE where the command is addressed. TID is the Telcordia name for the system.
11.13.4 ALL_MONTYPE
Monitoring type list
Table 11-23 ALL_MONTYPE Values
ALL_MONTYPE Values
|
Description
|
AISSP
|
Alarm Indication Signal Seconds-Path
|
CVCPP
|
Coding Violations - CP-Bit Path
|
CVL
|
Coding Violations - Line
|
CVP
|
Coding Violations - Path
|
CVV
|
Coding Violations - Section
|
ESCPP
|
Errored Seconds - CP-Bit Path
|
ESL
|
Errored Seconds - Line
|
ESP
|
Errored Seconds - Path
|
ESV
|
Errored Seconds - VT Path
|
FCL
|
Failure Count - Line
|
FCP
|
Failure Count - Path
|
LOSSL
|
Loss of Signal Seconds - Line
|
NPJC-PDET
|
PPJC-PDET:Negative Pointer Justification
|
NPJC-PGEN
|
PPJC-PDEN:Negative Pointer Justification
|
PPJC-PDET
|
PPJC-PDET:Positive Pointer Justification
|
PPJC-PGEN
|
PPJC-PDEN:Positive Pointer Justification
|
PSC
|
Protection Switching Count
|
PSD
|
Protection Switching Duration
|
SASCPP
|
Severely Errored Framing/AIS Second - CP-Bit Path
|
SASP
|
Severely Errored Framing/AIS Seconds
|
SEFS
|
Severely Errored Framing Seconds
|
SESCPP
|
Severely Errored Second - CP-Bit Path
|
SESL
|
Severely Errored Second - Line
|
SESP
|
Severely Errored Second - Path
|
SESV
|
Severely Errored Second - VT Path
|
UASCPP
|
Unavailable Second - CP-Bit Path
|
UASL
|
Unavailable Second - Line
|
UASP
|
Unavailable Second - Path
|
UASV
|
Unavailable Second - VT Path
|
11.13.5 ALL_THR
Threshold list
Table 11-24 ALL_THR Value
ALL_THR Values
|
Description
|
T-AISSP
|
Alarm Indication Signal Seconds-Path
|
T-CVCPP
|
Coding Violations - CP-Bit Path
|
T-CVL
|
Coding Violations - Line
|
T-CVP
|
Coding Violations - Path
|
T-CVS
|
Coding Violations - Section
|
T-CVV
|
Coding Violations - VT Path
|
T-ESCPP
|
Errored Seconds - CP-Bit Path
|
T-ESL
|
Errored Seconds - Line
|
T-ESP
|
Errored Seconds - Path
|
T-ESS
|
Errored Seconds - Section
|
T-ESV
|
Errored Seconds - VT Path
|
T-FCL
|
Failure Count - Line
|
T-FCP
|
Failure Count - Path
|
T-LOSSL
|
Loss of Signal Seconds - Line
|
T-PJNEG
|
PPJC-PDET:Negative Pointer Justification
|
T-PJNEG-GEN
|
PPJC-PGEN:Negative Pointer Justification
|
T-PJPOS
|
PPJC-PDET:Positive Pointer Justification
|
T-PJPOS-GEN
|
PPJC-PGEN:Positive Pointer Justification
|
T-PSC
|
Protection Switching Count
|
T-PSD
|
Protection Switching Duration
|
T-SASCPP
|
Severely Errored Framing/AIS Second - CP-Bit Path
|
T-SASP
|
Severely Errored Framing/AIS Seconds
|
T-SEFS
|
Severely Errored Framing Seconds
|
T-SESCPP
|
Severely Errored Second - CP-Bit Path
|
T-SESL
|
Severely Errored Second - Line
|
T-SESP
|
Severely Errored Second - Path
|
T-SESS
|
Severely Errored Second - Section
|
T-SESV
|
Severely Errored Second - VT Path
|
T-UASCPP
|
Unavailable Second - CP-Bit Path
|
T-UASL
|
Unavailable Second - Line
|
T-UASP
|
Unavailable Second - Path
|
T-UASV
|
Unavailable Second - VT Path
|
11.13.6 CCT
Defines the type of cross-connect to be created.
Table 11-25 CCT Values
CCT Values
|
Description
|
1WAY
|
A unidirectional connection from a source tributary to a destination tributary
|
2WAY
|
A bidirectional connection between the two tributaries
|
MON
|
Monitored cross connection
|
11.13.7 COND_EFF
The affected unit's condition
Table 11-26 COND_EFF Values
COND_EFF Values
|
Description
|
CL
|
Standing condition cleared
|
SC
|
Standing condition raised
|
TC
|
Transient condition
|
11.13.8 CONDITION
The condition type of the alarm indication
Table 11-27 CONDITION Values
CONDITION Values
|
Description
|
ACOMAN
|
Alarm cutoff is in manual mode
|
AIS
|
External failure - Incoming - Alarm Indication Signal
|
AIS-L
|
External failure - Incoming - Alarm Indication Signal - Line
|
AIS-P
|
External failure - Incoming - Alarm Indication Signal - Path
|
AIS-V
|
External failure - Incoming - Alarm Indication Signal - VT layer
|
APSB
|
External failure - Incoming - Automatic Protection Switching Channel - Byte failure
|
APSC
|
External failure - Incoming - Automatic Protection Switching Channel failure
|
APSC-IMP
|
External failure - Incoming - Automatic Protection Switching - Invalid K bytes
|
APSCCONNL
|
External failure - Incoming - Automatic Protection Switching - Connection Loss
|
APSCDFLTK
|
External failure - Incoming - Automatic Protection Switching - Default K byte
|
APSCINCON
|
External failure - Incoming - Automatic Protection Switching - Inconsistent
|
APSCM
|
External failure - Incoming - Automatic Protection Switching Channel - Protection Switching Channel Match failure
|
APSCNMIS
|
APS Channel - BLSR - Node ID Mismatch
|
APSMM
|
External failure - Incoming - Automatic Protection Switching Channel - Automatic Protection Switch Mode Mismatch
|
AUTOLSROFF
|
Internal hardware - Facility Termination Equipment - Automatic Laser Shutdown
|
AUTORESET
|
Recovery action - Automatic System Reset
|
AUTOSW-AIS
|
Automatic Switch - Alarm Indication Signal
|
AUTOSW-LOP
|
Automatic Switch - Loss of Pointer
|
AUTOSW-PDI
|
Automatic Switch - Payload Defect Indication
|
AUTOSW-SDBER
|
Automatic Switch - Signal Degrade Bit Error Rate
|
AUTOSW-SFBER
|
Automatic Switch - Signal Fail Bit Error Rate
|
AUTOSW-UNEQ
|
Automatic Switch - Unequipped
|
BKUPMEMP
|
Internal hardware - Control Equipment - Primary Non-Volatile Backup Memory Failure
|
BKUPMEMS
|
Internal hardware - Control Equipment - Secondary Non-Volatile Backup Memory Failure
|
BLSR-RESYNC
|
Bidirectional Line Switched Ring - Tables Resynchronized
|
BLSROOSYNC
|
Bidirectional Line Switched Ring - Out of Sync
|
BPV
|
External failure - Incoming - Bipolar Violation
|
CARLOSS
|
External failure - Incoming - Carrier Loss on the LAN
|
CLDRESTART
|
Recovery action - Cold Restart
|
CONCAT
|
STS Concatenation Error
|
CONTBUS
|
Control Bus Failure
|
CONTBUS-1
|
Control Bus Failure - 1
|
CONTBUS-2
|
Control Bus Failure - 2
|
CONTBUS-A-1
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 1
|
CONTBUS-A-2
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 2
|
CONTBUS-A-3
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 3
|
CONTBUS-A-4
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 4
|
CONTBUS-A-5
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 5
|
CONTBUS-A-6
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 6
|
CONTBUS-A-7
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 7
|
CONTBUS-A-8
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 8
|
CONTBUS-A-9
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 9
|
CONTBUS-A-10
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 10
|
CONTBUS-A-11
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 11
|
CONTBUS-A-12
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 12
|
CONTBUS-A-13
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 13
|
CONTBUS-A-14
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 14
|
CONTBUS-A-15
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 15
|
CONTBUS-A-16
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 16
|
CONTBUS-A-17
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 17
|
CONTBUS-A-18
|
TCC/TCC+ card in Slot 7 has lost communication with the card in Slot 18
|
CONTBUS-B-1
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 1
|
CONTBUS-B-2
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 2
|
CONTBUS-B-3
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 3
|
CONTBUS-B-4
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 4
|
CONTBUS-B-5
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 5
|
CONTBUS-B-6
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 6
|
CONTBUS-B-7
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 7
|
CONTBUS-B-8
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 8
|
CONTBUS-B-9
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 9
|
CONTBUS-B-10
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 10
|
CONTBUS-B-11
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 11
|
CONTBUS-B-12
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 12
|
CONTBUS-B-13
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 13
|
CONTBUS-B-14
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 14
|
CONTBUS-B-15
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 15
|
CONTBUS-B-16
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 16
|
CONTBUS-B-17
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 17
|
CONTBUS-B-18
|
TCC/TCC+ card in Slot 11 has lost communication with the card in Slot 18
|
CONTCOM
|
Internal hardware - Control Equipment - Control Communications equipment failure
|
CONTEQPT
|
Internal hardware - Control Equipment failure
|
CONTR
|
Internal hardware - Control Equipment - Control processor failure
|
CTNEQPT
|
Internal hardware - Interconnection Equipment failure
|
CTNEQPT-PB1PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 1
|
CTNEQPT-PB1WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 1
|
CTNEQPT-PB2PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 2
|
CTNEQPT-PB2WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 2
|
CTNEQPT-PB3PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 3
|
CTNEQPT-PB3WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 3
|
CTNEQPT-PB4PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 4
|
CTNEQPT-PB4WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 4
|
CTNEQPT-PB5PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 5
|
CTNEQPT-PB5WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 5
|
CTNEQPT-PB6PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 6
|
CTNEQPT-PB6WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 6
|
CTNEQPT-PB12PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 12
|
CTNEQPT-PB12WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 12
|
CTNEQPT-PB13PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 13
|
CTNEQPT-PB13WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 13
|
CTNEQPT-PB14PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 14
|
CTNEQPT-PB14WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 14
|
CTNEQPT-PB15PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 15
|
CTNEQPT-PB15WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 15
|
CTNEQPT-PB16PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 16
|
CTNEQPT-PB16WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 16
|
CTNEQPT-PB17PROT
|
Failure of the main payload between the protect XC/XCVT card in Slot 10 and the reporting I/O card in Slot 17
|
CTNEQPT-PB17WORK
|
Failure of the main payload bus between the active XC/XCVT card in Slot 8 and the reporting I/O card in Slot 17
|
DATAFLT
|
Internal Error - Software Fault - Data integrity fault
|
EOC
|
Embedded Operations Channel (Section DCC) failure
|
EOC-DOWN
|
Embedded Operation Channel Fail
|
EQPT
|
Internal hardware - Critical alarm caused by equipment failure
|
EQPT-DIAG
|
Equipment failure - Diagnostics Failure
|
EQPT-FAIL
|
Equipment Failure - Board Failure
|
EQPT-MAC
|
Equipment Failure - Medium Access Control
|
ESW
|
External Error - Excessive Switching
|
EXCCOL
|
External Failure - Incoming - Excess collisions on the LAN
|
EXT
|
Failure Detected External to the NE
|
EXTERR
|
External Error
|
FA
|
Internal Hardware - Power Failure - Fuse Alarm
|
FAC
|
External failure - Incoming - Facility, critical alarm caused by DS-3 facility failure
|
FACTERM
|
Internal hardware - Facility Termination equipment failure
|
FAILTORLS
|
Internal hardware - Failure To Release from protection
|
FAILTOSW
|
Internal hardware - Failure To Switch to protection
|
FAILTOSW-PATH
|
Failure to switch from the working path to the protection path on a UPSR
|
FAILTOSWR
|
Failure to Switch to Protection in a Ring
|
FAILTOSWS
|
Failure to Switch to Protection in a Span
|
FAN
|
Fan Tray Failure
|
FE-AIS
|
Far-end DS-3 node is reporting an AIS
|
FE-DS1-MULTLOS
|
Multiple inputs detect a loss on the far-end
|
FE-DS1-NSA
|
Non-service affecting failure detected from the far-end DS-1
|
FE-DS1-SA
|
Service affecting failure detected from the far-end DS-1
|
FE-DS1-SNGLLOS
|
One of the DS-1 inputs on the far-end detects a LOS
|
FE-DS3-NSA
|
Non-service affecting failure detected from the far-end DS-3
|
FE-DS3-SA
|
Service affecting failure detected from the far-end DS-3
|
FE-EQPT-NSA
|
Non-service affecting equipment failure is detected from the far-end DS-3
|
FE-IDLE
|
Far-end node detects an idle DS-3 signal
|
FE-LOF
|
Far-end node reports a DS-3 loss of frame
|
FE-LOS
|
Far-end node reports a DS-3 loss of signal
|
FEBE
|
External failure - Incoming - Far End Block Error
|
FEPRLF
|
External failure - Incoming - Automatic Protection Switching Channel - Far End Protection Line Failure
|
FORCED-REQ
|
Forced switch request on facility/equipment
|
FRCDWKSWBK
|
Recovery action - Working facility/equipment forced to switch back to working
|
FRCDWKSWPR
|
Recovery action - Working facility/equipment forced to switch to protection unit
|
FRCDWKSWPR-PATH
|
Recovery action - Working facility/equipment forced to switch to protection unit - Path
|
FRCWKBK-R
|
Recovery action - Working facility/equipment forced to switch back to working - Ring
|
FRCWKBK-S
|
Recovery action - Working facility/equipment forced to switch back to working - Span
|
FRCWKPR-R
|
Recovery action - Working facility/equipment forced to switch to protection unit- Ring
|
FRCWKPR-S
|
Recovery action - Working facility/equipment forced to switch to protection unit- Span
|
FRNGSYNC
|
Free Running Synchronization mode
|
FSTSYNC
|
Fast Start Synchronization Mode
|
HITEMP
|
Internal hardware - Equipment failure - High temperature
|
HLDOVRSYNC
|
Holdover synchronization mode
|
IMPROPRMVL
|
Procedural Error - Improper Removal
|
INC
|
Incoming failure condition
|
INC-ISD
|
Incoming failure condition - Idle Signal Path
|
INIT
|
Recovery action - Initialization initiated
|
INT
|
Internal hardware fault or failure
|
INTERR
|
Error Internal to the NE Detected
|
INTMSGERR
|
Internal Error - Internal Message Error
|
INTSFT
|
Internal Error - Software Fault or failure
|
INVMACADR
|
Equipment Failure - Invalid MAC address
|
LKOUTPR-R
|
Lockout or Protection - Ring
|
LKOUTPR-S
|
Lockout or Protection - Span
|
LKOUTWK-R
|
Lockout of Working - Ring
|
LKOUTWK-S
|
Lockout of Working - Span
|
LOCKOUT-REQ
|
Lockout switch request on facility/equipment
|
LOCKOUTOFPR
|
Recovery action - Lockout of Protection
|
LOCKOUTOFPR-PATH
|
Recovery action - Lockout of Protection - Path
|
LOCKOUTOFWK
|
Recovery action - Lockout of working
|
LOF
|
External failure - Incoming - Loss of Frame
|
LOP
|
External failure - Incoming - Loss of Pointer
|
LOP-P
|
External failure - Incoming - Loss of Pointer - Path
|
LOP-V
|
Loss of pointer at the VT level
|
LOS
|
External failure - Incoming - Loss of Signal
|
LPBK
|
Loopback
|
LPBKDS1FEAC
|
DS-1 loopback signal is received from the far-end due to a Far-End Alarm and Control (FEAC) command
|
LPBKDS1FEAC-CMD
|
DS-1 loopback command sent by the ONS 15454 to the far-end equipment
|
LPBKDS3FEAC
|
DS-3 loopback signal is received from the far-end due to a Far-End Alarm and Control (FEAC) command
|
LPBKDS3FEAC-CMD
|
DS-3 loopback command sent by the ONS 15454 to the far-end equipment
|
LPBKFACILITY
|
Loopback, Facility
|
LPBKM23
|
DS-2 Loopback due to Far End Command
|
LPBKM23-CMD
|
DS-2 Loopback Command sent to Far End
|
LPBKNETWORK
|
Loopback, Network
|
LPBKTERMINAL
|
Loopback, Terminal
|
MAN
|
Manually caused abnormal condition
|
MAN-REQ
|
Manual Switch Request
|
MANRESET
|
Recovery action - Manual system Reset
|
MANSWTOINT
|
Recovery action - Manual synchronization switch to internal clock
|
MANSWTOPRI
|
Recovery action - Manual synchronization Switch To Primary reference
|
MANSWTOSEC
|
Recovery action - Manual synchronization Switch To Second reference
|
MANSWTOTHIRD
|
Recovery action - Manual synchronization Switch To Third reference
|
MANSWTOFOURTH
|
Recovery action - Manual synchronization Switch To Fourth reference
|
MANSWTOFIFTH
|
Recovery action - Manual synchronization Switch To Fifth reference
|
MANSWTOSIXTH
|
Recovery action - Manual synchronization Switch To Sixth reference
|
MANWKBK-R
|
Manual Switch of working facility/equipment to protection - Ring
|
MANWKBK-S
|
Manual Switch of working facility/equipment to protection - Span
|
MANWKPR-R
|
Manual Switch of working facility/equipment to protection unit - Ring
|
MANWKPR-S
|
Manual Switch of working facility/equipment to protection unit - Span
|
MANWKSWBK
|
Recovery action - Manual Switch or working facility/equipment to protection
|
MANWKSWPR
|
Recovery action - Manual Switch of Working facility/equipment to protection unit
|
MANWKSWPR-PATH
|
Recovery action - Manual Switch of Working facility/equipment to protection - Path
|
MEA
|
Internal error - Mismatch of Equipment and Attributes
|
MEM-GONE
|
Software operations exceed the memory capacity of the TCC/TCC+ card
|
MEM-LOW
|
Data generated by software operations is close to exceeding the memory capacity of the TCC/TCC+ card
|
NEW-ROOT
|
New root trap in BRIDGE-MIB
|
NORMAL
|
Normal condition - This condition type is used by the NE to report the returning to normal from a previous off-normal condition
|
OG
|
External failure - Outgoing failure condition
|
OOF
|
External failure - Incoming - Out of Frame
|
PATHSEL
|
External failure - Incoming - Path Selector inability to switch to a valid signal
|
PDI
|
External failure - Incoming - Signal Label Mismatch Failure - Payload Defect Indication
|
PDI-P
|
External failure - Incoming - Signal Label Mismatch Failure - Payload Defect Indication - Path
|
PEERMISSM
|
Peer state mismatch
|
PLM-P
|
External failure - Incoming - Signal Label Mismatch Failure - Payload Label Mismatch - Path
|
PLM-V
|
Content of the V5 byte in the SONET overhead is inconsistent or invalid
|
PLUG-IN
|
Internal hardware - Equipment unit plug-in
|
PM-TCA
|
Performance Monitoring - Threshold Crossing Alert
|
PRC-DUPID
|
Procedural Error - Duplicate Node ID
|
PRCDRERR
|
Procedural Error
|
PROGFLT
|
Internal Error - Software Fault - Program failure
|
PROTNA
|
Protection unit not available
|
PS
|
Occurrence of a protection switching event
|
PWR
|
Internal hardware - Power failure (detected internal to NE)
|
PWRRESTART
|
Recovery action - Powerfail Restart
|
RAI
|
External failure - Incoming - Remote Alarm Indication
|
RCVR
|
Internal hardware - Facility Termination equipment - Receiver failure
|
RCVR-MISS
|
Facility termination equipment detects a missing receive cable on the DS-1 port or a possible mismatch of backplane equipment
|
RCVRY
|
Recovery or service protection action has been initiated
|
RDI-L
|
External failure - Outgoing - Remote Defect Indication - Line
|
RDI-P
|
External failure - Outgoing - Remote Defect Indication - Path
|
RFI
|
External failure - Incoming - Remote Failure Indication
|
RFI-L
|
External failure - Incoming - Remote Failure Indication - Line
|
RFI-P
|
External failure - Incoming - Remote Failure Indication - Path
|
RFI-V
|
Upstream failure has occurred at the VT layer
|
RMON-ALARM
|
An RMON Alarm
|
RMON-RESET
|
RMON histories and alarms have been reset due to chipset reboot
|
SD
|
Facility has passed BER Threshold for Signal Degrade
|
SEF
|
External failure - Incoming - Severely Errored Frame
|
SF
|
Facility has passed BER threshold for Signal Failure
|
SLMF
|
External failure - Incoming - Signal Label Mismatch Failures - SONET
|
SQUELCH
|
Ring is isolated into two or more segments
|
SSM-DUS
|
Synchronization Status Messaging - Don't use for timing synchronization
|
SSM-FAIL
|
Synchronization Status Messaging - Failed
|
SSM-OFF
|
Synchronization Status Messaging - Off
|
SSM-PRS
|
Synchronization Status Messaging - Primary reference source - Stratum 1
|
SSM-RES
|
Synchronization Status Messaging - Reserved - quality level set by user
|
SSM-SMC
|
Synchronization Status Messaging - SONET minimum clock
|
SSM-ST2
|
Synchronization Status Messaging - Stratum 2
|
SSM-ST3
|
Synchronization Status Messaging - Stratum 3
|
SSM-ST3E
|
Synchronization Status Messaging - Stratum 3E
|
SSM-ST4
|
Synchronization Status Messaging - Stratum 4
|
SSM-STU
|
Synchronization Status Messaging - Sync traceability unknown
|
SSM-TNC
|
Synchronization Status Messaging - Transit node clock
|
SWFTDWN
|
Recovery action - Software download in progress
|
SWTOINT
|
Recovery action - Synchronization Switch To Internal clock
|
SWTOPRI
|
Recovery action - Synchronization Switch To Primary reference
|
SWTOSEC
|
Recovery action - Synchronization Switch To Second reference
|
SWTOTHIRD
|
Recovery action - Synchronization Switch To Third reference
|
SWTOFOURTH
|
Recovery action - Synchronization Switch To Fourth reference
|
SWTOFIFTH
|
Recovery action - Synchronization Switch To Fifth reference
|
SWTOSIXTH
|
Recovery action - Synchronization Switch To Sixth reference
|
SYNC
|
External failure - Incoming - Loss of timing on Synchronization link.
|
SYNCCLK
|
Internal hardware - Synchronization unit failure
|
SYNCEQPT
|
Internal hardware - Synchronization switching Equipment failure
|
SYNCOOS
|
External failure - Incoming - Loss of timing on all specified synchronization links
|
SYNCPRI
|
External failure - Incoming - Loss of timing on primary synchronization link
|
SYNCSEC
|
External failure - Incoming - Loss of timing on secondary synchronization link
|
SYNCTHIRD
|
External failure - Incoming - Loss of timing on third synchronization link
|
SYNCFOURTH
|
External failure - Incoming - Loss of timing on fourth synchronization link
|
SYNCFIFTH
|
External failure - Incoming - Loss of timing on fifth synchronization link
|
SYNCSIXTH
|
External failure - Incoming - Loss of timing on sixth synchronization link
|
SYSBOOT
|
Activation of new software
|
TOP-CHANGE
|
Topology Change trap in BRIDGE-MIB
|
TRMT
|
Internal hardware - Facility Termination equipment - Transmit failure
|
TRMT-MISS
|
Facility termination equipment detects a missing transmit cable on the DS-1 port or a possible mismatch of backplane equipment
|
TSI
|
Internal hardware - Interconnection Equipment - Time slot interchange equipment failure
|
UNEQ-P
|
External failure - Incoming - Signal Label Mismatch Failure - Unequipped - Path
|
UNEQ-V
|
VT is receiving an unequipped signal
|
UNPLUG
|
Internal hardware - Equipment unit un-plug
|
WATM-TO
|
Internal Error - Watchdog Timer Timeout
|
WKGMEM
|
Internal hardware - Control Equipment -Working memory failure
|
WKSWBK
|
Recovery action - Working facility/equipment switched back to working
|
WKSWPR
|
Recovery action - Working facility/equipment switched to protection unit
|
WRMRESTART
|
Recovery action - Warm Restart
|
WTR
|
Recovery action - SONET line is in Wait To Restore state
|
11.13.9 DIRECTION
Transmit and receive directions
Table 11-28 DIRECTION Values
DIRECTION Values
|
Description
|
BTH
|
Both transmit and receive directions
|
RCV
|
Receive direction only
|
TRMT
|
Transmit direction only
|
11.13.10 DS3_FMT
Indicates a DS-3 digital signal format
Table 11-29 DS3_FMT Values
DS3_FMT Values
|
Description
|
ASYNC
|
The DS-3 digital signal format is ASYNC
|
CBIT
|
The DS-3 digital signal format is C-BIT
|
SYNC
|
The DS-3 digital signal format is SYNC
|
UNFR
|
The DS-3 digital signal format is unframed
|
11.13.11 DS_LINE_CODE
DS-123 Line Code
Table 11-30 DS_LINE_CODE Values
DS_LINE_CODE Values
|
Description
|
B3ZS
|
Bipolar with Three-Zero Substitution
|
11.13.12 DS_LINE_TYPE
DS-123 Line type
Table 11-31 DS_LINE_TYPE Values
DS_LINE_TYPE Values
|
Description
|
C-BIT
|
C-BIT line type applies to DS3XM card
|
M23
|
M23 line type applies to DS3XM card
|
UNFRAMED
|
Line Type is Unframed
|
11.13.13 DX_MODE_OP
Duplex switch operation mode
Table 11-32 DX_MODE_OP Values
DX_MODE_OP Values
|
Description
|
FRCD
|
Forced Switch
|
MAN
|
Manual Switch
|
11.13.14 E_LBO
Electrical signal line buildout
Table 11-33 E_LBO Values
E_LBO Values
|
Description
|
0-225
|
Electrical signal buildout range is 0-255
|
226-450
|
Electrical signal buildout range is 255-450
|
11.13.15 ENV_ALM
Environmental alarm types as defined by Telcordia GR-833-CORE, Issue 2, November 1996, Appendix F.
Table 11-34 ENV_ALM Values
ENV_ALM Values
|
Description
|
AIRCOMPR
|
Air compressor failure
|
AIRCOND
|
Air conditioning failure
|
AIRDRYR
|
Air dryer failure
|
BATDSCHRG
|
Battery discharging
|
BATTERY
|
Battery failure
|
CLFAN
|
Cooling fan failure
|
CPMAJOR
|
Centralized power major failure
|
CPMINOR
|
Centralized power minor failure
|
ENGINE
|
Engine failure
|
ENGOPRG
|
Engine operating
|
EXPLGS
|
Explosive gas
|
FIRDETR
|
Fire detector failure
|
FIRE
|
Fire
|
FLOOD
|
Flood
|
FUSE
|
Fuse failure
|
GEN
|
Generator failure
|
HIAIR
|
High airflow
|
HIHUM
|
High humidity
|
HITEMP
|
High temperature
|
HIWTR
|
High water
|
INTRUDER
|
Intrusion
|
LWBATVG
|
Low battery voltage
|
LWFUEL
|
Low fuel
|
LWHUM
|
Low humidity
|
LWPRES
|
Low cable pressure
|
LWTEMP
|
Low temperature
|
LWWTR
|
Low water
|
MISC
|
Miscellaneous
|
OPENDR
|
Open door
|
POWER
|
Commercial power failure
|
PUMP
|
Pump failure
|
PWR-48
|
48 Volt power supply failure
|
RECT
|
Rectifier failure
|
RECTHI
|
Rectifier high voltage
|
RECTLO
|
Rectifier low voltage
|
SMOKE
|
Smoke
|
TOXICGAS
|
Toxic gas
|
VENTN
|
Ventilation system failure
|
11.13.16 ENV_CTL
Environmental control types as defined by Telcordia GR-833-CORE, Issue 2, November 1996, Appendix G.
Table 11-35 ENV_CTL Values
ENV_CTL Values
|
Description
|
AIRCOND
|
Air conditioning
|
ENGINE
|
Engine
|
FAN
|
Fan
|
GEN
|
Generator
|
HEAT
|
Heat
|
LIGHT
|
Light
|
MISC
|
Miscellaneous
|
SPKLR
|
Sprinkler
|
11.13.17 EQPT_TYPE
Identifies the type of equipment being provisioned into a slot.
Table 11-36 EQPT_TYPE Values
EQPT_TYPE Values
|
Description
|
AIC
|
The Alarm Interface Controller Card is an optional card which expands system management capabilities for the customer defined alarm I/O and orderwire functionality
|
DCC
|
The Data Communications Channel communicates network management information
|
DS1-14
|
A 14 port interface card supporting DS-1 facilities
|
DS1N-14
|
A 14 port interface card supporting DS-1 facilities
|
DS3-12
|
A 12 port interface card supporting DS-3 facilities
|
DS3CR-12
|
Cost reduced DS-3
|
DS3N-12
|
A 12 port interface card supporting DS-3 facilities
|
DS3XM-6
|
An interface card that converts six framed DS-3 network connections to 28x6 or 168 VT1.5s
|
E1000T-2
|
A two port interface card supporting 1000 Base T ethernet facilities
|
E100T-12
|
A 12 port interface card supporting 100 Base T ethernet facilities
|
EC1-12
|
A 12 port interface card supporting EC-1 facilities
|
EC1N-12
|
A 12 port interface card supporting EC-1 facilities
|
OC-12
|
An interface card that supports one or more OC-12 (622Mbs) optical facilities
|
OC12-IR-1
|
An interface card that supports one intermediate range OC-12 (622Mbs) optical facilities
|
OC12-LR-1
|
An interface card that supports one long range OC-12 (622Mbs) optical facilities
|
OC12-SR-1
|
An interface card that supports one short range OC-12 (622Mbs) optical facilities
|
OC192-LR-1
|
An interface card that supports one or more long range OC-192 optical facilities
|
OC-3
|
An interface card that supports multiple OC-3 (155Mbs) optical facilities
|
OC3-IR-4
|
An interface card that supports four intermediate range OC-3 (155Mbs) optical facilities
|
OC3-SR-4
|
An interface card that supports four short range OC-3 (155Mbs) optical facilities
|
OC-48
|
An interface card that supports one or more OC-48 (10Gbs) optical facilities
|
OC48-IR-1
|
An interface card that supports one intermediate range OC-48 (10Gbs) optical facilities
|
OC48-LR-1
|
An interface card that supports one long range OC-48 (10Gbs) optical facilities
|
OC48-SR-1
|
An interface card that supports one short range OC-48 (10Gbs) optical facilities
|
TCC
|
The Timing, Communication and Control card
|
TCC+
|
The Timing, Communication and Control+ card
|
XC
|
A Cross-Connect card
|
XC-192
|
A Cross-Connect card
|
XC-VT
|
A Cross-Connect card
|
11.13.18 EQUIP
Indicates the presence of a plug-in unit
Table 11-37 EQUIP Values
EQUIP Values
|
Description
|
EQUIP
|
The unit is Equipped - present
|
UNEQUIP
|
The unit is Unequipped - absent
|
11.13.19 EQUIPMENT_TYPE
Table 11-38 EQUIPMENT_TYPE Values
EQUIPMENT_TYPE Values
|
Description
|
AIC
|
AIC card
|
DS-1
|
DS-1 card
|
DS-1N
|
DS-1N card
|
DS-3
|
DS-3 card
|
DS-3N
|
DS-3N card
|
DS3XM
|
DS3XM card
|
E-100T
|
E-100T card
|
E-1000T
|
E-1000T card
|
EC-1
|
EC-1 card
|
EC-1N
|
EC-1N card
|
OC-12
|
OC-12 card
|
OC-3
|
OC-3 card
|
OC-48
|
OC-48 card
|
TCC
|
TCC card
|
TCC+
|
TCC+ card
|
XC-STS
|
XC-STS card
|
XC-VT
|
XC-VT card
|
11.13.20 EXT_RING
Indicates if the ring supports the extended K1/K2/K3 protocol.
Table 11-39 EXT_RING Values
EXT_RING Values
|
Description
|
N
|
Indicates the Ring does not support the extended K1/K2/K3 protocol
|
Y
|
Indicates the Ring does support the extended K1/K2/K3 protocol
|
11.13.21 FRAME_FORMAT
The frame format for a T1 port
Table 11-40 FRAME_FORMAT Values
FRAME_FORMAT Values
|
Description
|
D4
|
Frame format is D4
|
ESF
|
Frame format is ESF
|
UNFRAMED
|
Frame format is unframed
|
11.13.22 LINE_BUILDOUT
Table 11-41 LINE_BUILDOUT Values
LINE_BUILDOUT Values
|
Description
|
0-131
|
Line buildout range is 0-131
|
132-262
|
Line buildout range is 132-262
|
263-393
|
Line buildout range is 263-393
|
394-524
|
Line buildout range is 394-524
|
525-655
|
Line buildout range is 525-655
|
11.13.23 LINE_CODE
Table 11-42 LINE_CODE Values
LINE_CODE Values
|
Description
|
AMI
|
Line code value is AMI
|
B8ZS
|
Line code value is B8ZS (Bipolar with Eight-Zero Substitution)
|
11.13.24 LOCATION
Identifies the location where the action is to take place
Table 11-43 LOCATION Values
LOCATION Values
|
Description
|
FEND
|
Action occurs on the Far End of the facility
|
NEND
|
Action occurs on the Near End of the facility
|
11.13.25 LPBK_TYPE
Indicates the type of loopback that is to be operated or released
Table 11-44 LPBK_TYPE Values
LPBK_TYPE Values
|
Description
|
FACILITY
|
A type of loopback that connects the incoming received signal immediately following the optical-to-electrical conversion (before descrambling) to the associated transmitter in the return direction
|
TERMINAL
|
A loopback that connects the signal that is about to be transmitted (after scrambling but before the electrical-to-optical conversion) is connected to the associated, incoming receiver
|
11.13.26 MOD2
A generic object type
Table 11-45 MOD2 Values
MOD2 Values
|
Description
|
DS-1
|
DS-1 facility on DS3XM
|
EC-1
|
EC-1 facility
|
OC-12
|
OC-12 facility
|
OC-3
|
OC-3 facility
|
OC-48
|
OC-48 facility
|
STS-1
|
STS path
|
STS-12C
|
STS path
|
STS-3C
|
STS path
|
STS-48C
|
STS path
|
T1
|
DS-1 facility
|
T3
|
DS-3 facility
|
VT1
|
VT1 path
|
11.13.27 MOD2ALM
Alarm type for certain generic TL1 commands
Table 11-46 MOD2ALM Values
MOD2ALM Values
|
Description
|
DS-1
|
DS-1 alarm
|
E-100
|
E-100 alarm
|
E-1000
|
E-1000 alarm
|
EC-1
|
EC-1 alarm
|
OC-12
|
OC-12 alarm
|
OC-3
|
OC-3 alarm
|
OC-48
|
OC-48 alarm
|
STS-1
|
STS-1 alarm
|
STS-12C
|
STS-12C alarm
|
STS-3C
|
STS-3C alarm
|
STS-48C
|
STS-48C alarm
|
T1
|
T1 alarm
|
T3
|
T3 alarm
|
VT1
|
VT1 alarm
|
11.13.28 MOD2B
Alarm type for certain generic TL1 commands
Table 11-47 MOD2B Values
MOD2B Values
|
Description
|
BITS
|
BITS alarm
|
COMM
|
COMM alarm
|
DS-1
|
DS-1 alarm
|
E-100
|
E-100 alarm
|
E-1000
|
E-1000 alarm
|
EC-1
|
EC-1 alarm
|
ENV
|
ENV alarm
|
EQPT
|
EQPT alarm
|
OC-12
|
OC-12 alarm
|
OC-3
|
OC-3 alarm
|
OC-48
|
OC-48 alarm
|
STS-1
|
STS alarm
|
STS-12C
|
STS alarm
|
STS-3C
|
STS alarm
|
STS-48C
|
STS alarm
|
SYNCN
|
SYNCN alarm
|
T1
|
T1 alarm
|
T3
|
T3 alarm
|
TCC
|
TCC alarm
|
TCC+
|
TCC+ alarm
|
VT1
|
VT alarm
|
11.13.29 MODIFIER
Modifier for certain TL1 commands that are generic in their syntax
Table 11-48 MODIFIER Values
MODIFIER Values
|
Description
|
BITS
|
BITS command modifier
|
EQPT
|
Equipment command modifier
|
OC-12
|
OC-12 command modifier
|
OC-3
|
OC-3 command modifier
|
OC-48
|
OC-48 command modifier
|
STS-1
|
STS-1 command modifier
|
STS-12C
|
STS-12c command modifier
|
STS-3C
|
STS-3c command modifier
|
SYNCN
|
Synchronization command modifier
|
T3
|
T3/DS-3 command modifier
|
11.13.30 NOTIF_CODE
The 2-character Notification Code associated with an autonomous message
Table 11-49 NOTIF_CODE Values
NOTIF_CODE Values
|
Description
|
CL
|
The condition causing the alarm has Cleared
|
CR
|
A Critical alarm
|
MJ
|
A Major alarm
|
MN
|
A Minor alarm
|
NA
|
The condition is Not Alarmed
|
NR
|
The alarm is not reported
|
11.13.31 OCN_MONTYPE
OCN monitor type
Table 11-50 OCN_MONTYPE Values
OCN_MONTYPE Values
|
Description
|
CVL
|
Coding Violation - Line
|
ESL
|
Errored Second - Line
|
PJNEG
|
PPJC-PDET:Negative Pointer Justification
|
PJPOS
|
PPJC-PGEN:Negative Pointer Justification
|
PSC
|
Protection Switching Count
|
PSD
|
Protection Switching Duration
|
SEFS
|
Severely Errored Framing Seconds
|
UASL
|
Unavailable Second - Line
|
11.13.32 OCN_TYPE
Modifier used to differentiate the various levels of OC-N in the ENT/ED/DLT commands
Table 11-51 OCN_TYPE Values
OCN_TYPE Values
|
Description
|
OC-12
|
Optical Carrier level-12 (622Mbs)
|
OC-3
|
Optical Carrier level-3 (155Mbs)
|
OC-48
|
Optical Carrier level-48 (2.4Gbs)
|
11.13.33 ON_OFF
Disable or Enable Mode
Table 11-52 ON_OFF Values
ON_OFF Values
|
Description
|
OFF
|
Mode is disabled
|
ON
|
Mode is enabled
|
11.13.34 OPTICAL_MODE
Table 11-53 OPTICAL_MODE Values
OPTICAL_MODE Values
|
Description
|
SDH
|
The SDH optical mode the European format
|
SONET
|
The SONET optical mode the American format
|
11.13.35 PRIVILEGE
Security level
Table 11-54 PRIVILEGE Values
PRIVILEGE Values
|
Description
|
MAINT
|
Maintenance Security Level
|
PROV
|
Provision Security Level
|
RTRV
|
Retrieve Security Level
|
SUPER
|
Superuser Security Level
|
11.13.36 PROT_MOD_OP
Protection switch operation mode
Table 11-55 PROT_MOD_OP Values
PROT_MOD_OP Values
|
Description
|
FRCD
|
Force switch operation mode
|
MAN
|
Manual switch operation mode
|
11.13.37 PROTECTION_GROUP
Table 11-56 PROTECTION_GROUP Values
PROTECTION_GROUP Values
|
Description
|
1-1
|
1 to 1 protection group
|
1-N
|
1 to N protection group
|
11.13.38 PST
Primary State of the entity (e.g. facility)
Table 11-57 PST Values
PST Values
|
Description
|
IS
|
In-service
|
OOS
|
Out-of-Service
|
11.13.39 REVERTIVE_TIME
Table 11-58 REVERTIVE_TIME Values
REVERTIVE_TIME Values
|
Description
|
0.0 - 12.0
|
Revertive time is 0.0 to 12.0 minutes
|
11.13.40 REVERTIVE_TYPE
Table 11-59 REVERTIVE_TYPE Values
REVERTIVE_TYPE Values
|
Description
|
NR
|
Revertive type is disabled
|
R
|
Revertive type is enabled
|
11.13.41 RNG_TYPE
Defines the type of ring that is to be deployed for this path
Table 11-60 RNG_TYPE Values
RNG_TYPE Values
|
Description
|
BLSR2
|
2-Fiber Bidirectional Line Switched Ring
|
BLSR4
|
4-Fiber Bidirectional Line Switched Ring
|
UPSR
|
Unidirectional Path Switched Ring
|
11.13.42 SD_BER
The threshold for declaring Signal Degrade on a facility or path
Table 11-61 SD_BER Values
SD_BER Values
|
Description
|
1E-5 - 1E-9
|
SDBER is the 1E-5 to 1E-9
|
11.13.43 SDCC_MODE
Enables or disables the Section Data Communications Channel (SDCC) for the specified facility
Table 11-62 SDCC_MODE Values
SDCC_MODE Values
|
Description
|
N
|
Section Data Communications Channel is disabled for this facility
|
Y
|
Section Data Communications Channel is enabled for this facility
|
11.13.44 SERV_EFF
Indicates the effect of the alarm on service
Table 11-63 SERV_EFF Values
SERV_EFF Values
|
Description
|
NSA
|
The condition is Non-Service Affecting
|
SA
|
The condition is Service Affecting
|
11.13.45 SF_BER
The threshold for declaring Signal Failure on a facility or path
Table 11-64 SF_BER Values
SF_BER Values
|
Description
|
1E-3 - 1E-5
|
SFBER is the 1E-3 to 1E-5
|
11.13.46 SIDE
The role the unit is playing in the protection group
Table 11-65 SIDE Values
SIDE Values
|
Description
|
PROT
|
The entity is the protection unit in the protection group
|
WORK
|
The entity is a working unit in the protection group
|
11.13.47 STATE
The provisioned state of the equipment unit or facility
Table 11-66 STATE Values
STATE Values
|
Description
|
IS
|
The entity is InService
|
OOS-AS
|
The entity is Out-Of-Service and Assigned
|
OOS-UAS
|
The entity is Out-Of-Service and UnAssigned
|
11.13.48 STATUS
Indicates whether the unit in the pair is Active or Standby
Table 11-67 Status Values
STATUS Values
|
Description
|
ACT
|
The entity is the Active unit in the protection group
|
NA
|
Status is unavailable
|
STBY
|
The entity is the standby unit in the protection group
|
11.13.49 STM_TYPE
The Synchronous Transport Mode of the NE
Table 11-68 STM_TYPE Values
STM_TYPE Values
|
Description
|
SDH
|
The NE is operating in Synchronous Digital Hierarchy mode
|
SONET
|
The NE is operating in Synchronous Optical NETwork mode
|
11.13.50 STS_MONTYPE
Table 11-69 STS_MONOTYPE Values
STS_MONTYPE Values
|
Description
|
CVP
|
Coding Violation - P
|
ESP
|
Errored Second - Path
|
SESP
|
Severely Errored Second - Path
|
UASP
|
Unavailable Second - Path
|
11.13.51 STS_PATH
Modifier for some of the STS commands
Table 11-70 STS_PATH Values
STS_PATH Values
|
Description
|
STS-1
|
Synchronous Transport Signal level-1 (51Mbs)
|
STS-12C
|
Synchronous Transport Signal level-12 Concatenated (622Mbs)
|
STS-3C
|
Synchronous Transport Signal level-3 Concatenated (155Mbs)
|
11.13.52 SWITCH
The type of switch to be initiated
Table 11-71 SWITCH Values
SWITCH Values
|
Description
|
FRCD
|
Force a switch unless another FRCD or LOCKOUT is in effect
|
LOCKOUT
|
Locks the facility out of switching. The system cannot switch to the protect facility to carry service
|
MAN
|
Requests a manual switch of the facility
|
11.13.53 SYNC_GENERATION
Synchronization status message set generation
Table 11-72 SYNC_GENERATION Values
SYNC_GENERATION Values
|
Description
|
GEN1
|
First generation SSM set
|
GEN2
|
Second generation SSM set
|
11.13.54 SYNC_MODE
Table 11-73 SYNC_MODE Values
SYNC_MODE Values
|
Description
|
FRNG
|
Reset operation mode
|
FST
|
Reset operation mode
|
HLDOVR
|
Reset operation mode
|
NORM
|
Reset operation mode
|
11.13.55 SYNC_QUALITY_LEVEL
Reserved for network synchronization quality level
Table 11-74 SYNC_QUALITY_LEVEL Values
SYNC_QUALITY_LEVEL Values
|
Description
|
ABOVE-PRS
|
Better than Primary Reference Source
|
ABOVE-SMC
|
Between SMC and ST3
|
ABOVE-ST2
|
Between ST2 and STU
|
ABOVE-ST3
|
Between ST3 and ST2
|
ABOVE-ST3E
|
Between ST3E and TNC
|
ABOVE-ST4
|
Between ST4 and ST3
|
ABOVE-STU
|
Between STU and PRS
|
ABOVE-TNC
|
Between TNC and PRS
|
BELOW-ST4
|
Below ST4 but still usable
|
SAME-AS-DUS
|
Disable the RES message by equating it to DUS
|
11.13.56 TIMING_MODE
Timing mode for the current node
Table 11-75 TIMING_MODE Values
TIMING_MODE Values
|
Description
|
EXTERNAL
|
The node derives its clock from the BITS input
|
LINE
|
The node derives its clock from the SONET lines
|
11.13.57 TMG_REF
Identifies whether or not this entity is the Timing Reference for its group. For equipment, it identifies the facility that is supplying the timing reference. For interface groups, it identifies the card that is supplying the main timing reference.
Table 11-76 TMG_REF Values
TMG_REF Values
|
Description
|
N
|
This facility or card is not a timing reference
|
Y
|
This facility or card is a timing reference
|
11.13.58 TMPR
Performance parameter
Table 11-77 TMPR Values
TMPR Values
|
Description
|
15MIN
|
Performance Parameter Accumulation Interval Length - Every 15 Minutes
|
1DAY
|
Performance Parameter Accumulation Interval Length - Every 24 Hours
|
11.13.59 USE_DST
Identifies whether Daylight Saving Time is recognized in the area where this NE is deployed
Table 11-78 USE_DST Values
USE_DST Values
|
Description
|
N
|
Daylight Saving Time is not recognized
|
Y
|
Daylight Saving Time is recognized
|
11.13.60 VALIDITY
Response validity
Table 11-79 VALIDITY Values
VALIDITY Values
|
Description
|
COMPL
|
Complete Response
|
PRTL
|
Partial Response
|
11.13.61 Performance Monitoring Parameters by Line Type
Table 11-80 Performance Monitoring Parameters by Line Type
|
OC-n
|
T1
|
T3
|
STS
|
VT1.5
|
CVL
|
Y
|
Y
|
Y
|
|
|
CVP
|
|
Y
|
Y
|
Y
|
|
CVS
|
Y
|
|
|
|
|
CVV
|
|
|
|
|
Y
|
ESL
|
Y
|
Y
|
Y
|
|
|
ESP
|
|
Y
|
Y
|
Y
|
|
ESS
|
Y
|
|
|
|
|
ESV
|
|
|
|
|
Y
|
FCP
|
|
|
|
Y
|
|
FCL
|
Y
|
|
|
|
|
PJNEG
|
Y
|
|
|
|
|
PJPOS
|
Y
|
|
|
|
|
PSC
|
Y
|
|
|
|
|
PSD
|
Y
|
|
|
|
|
SASP
|
|
Y
|
Y
|
|
|
SEFS
|
Y
|
|
|
|
|
SESL
|
Y
|
Y
|
Y
|
|
|
SESP
|
|
Y
|
Y
|
Y
|
|
SESS
|
Y
|
|
|
|
|
SESV
|
|
|
|
|
Y
|
UASL
|
Y
|
|
|
|
|
UASP
|
|
Y
|
Y
|
Y
|
|
UASV
|
|
|
|
|
Y
|
AISSP
|
|
Y
|
Y
|
|
|
CVCPP
|
|
|
Y
|
|
|
ESCPP
|
|
|
Y
|
|
|
LOSSL
|
|
|
Y
|
|
|
SASCPP
|
|
|
Y
|
|
|
SESCPP
|
|
|
Y
|
|
|
UASCPP
|
|
|
Y
|
|
|
11.14 Errors
Errors may be generated by any command or command response message. The format of an error message is as follows:
sid date time
M ctag DENY
<errcde>
/* <errmsg> */
;
Table 11-81 Error Codes
Error Code
(errcde)
|
Error Type
|
Error Message (errmsg)
|
EANS
|
EQUIPAGE
|
Access Not Supported
|
EATN
|
EQUIPAGE
|
Not Valid for Access Type
|
EFON
|
EQUIPAGE
|
Feature Option Not Provided
|
EN2T
|
EQUIPAGE
|
Not 2-Wire Terminate and Leave
|
ENAC
|
EQUIPAGE
|
Not Equipped with Alarm Cutoff
|
ENAD
|
EQUIPAGE
|
Not Equipped with Audit Capability
|
ENAR
|
EQUIPAGE
|
Not Equipped with Automatic Reconfiguration
|
ENAT
|
EQUIPAGE
|
Request Not Valid for Access Type
|
ENDG
|
EQUIPAGE
|
Not Equipped with Diagnostic Capability
|
ENDS
|
EQUIPAGE
|
Not Equipped with Duplex Switching
|
ENEA
|
EQUIPAGE
|
Not Equipped with Error Analysis Capability
|
ENEQ
|
EQUIPAGE
|
Not Equipped
|
ENEX
|
EQUIPAGE
|
Not Equipped with Exercise Capability
|
ENFE
|
EQUIPAGE
|
Feature Not Provided
|
ENFL
|
EQUIPAGE
|
Not Equipped for Fault Locating
|
ENHN
|
EQUIPAGE
|
Not Hybrid Network
|
ENMB
|
EQUIPAGE
|
Not Multipoint Bridge
|
ENMD
|
EQUIPAGE
|
Not Equipped with Memory Device
|
ENPM
|
EQUIPAGE
|
Not Equipped for Performance Monitoring
|
ENPS
|
EQUIPAGE
|
Not Equipped with Protection Switching
|
ENRE
|
EQUIPAGE
|
Not Recognized Equipage
|
ENRI
|
EQUIPAGE
|
Not Equipped for Retrieving Specified Information
|
ENRS
|
EQUIPAGE
|
Not Equipped for Restoration
|
ENSA
|
EQUIPAGE
|
Not Equipped for Scheduling Audit
|
ENSG
|
EQUIPAGE
|
Not Software Generic
|
ENSI
|
EQUIPAGE
|
Not Equipped for Setting Specified Information
|
ENSS
|
EQUIPAGE
|
Not Equipped with Synchronization Switching
|
ENTL
|
EQUIPAGE
|
Not Terminate and Leave
|
ERLC
|
EQUIPAGE
|
Red-Lined Circuit
|
ERNS
|
EQUIPAGE
|
RTU Does Not Support Command
|
ESPG
|
EQUIPAGE
|
Software Program
|
ETNS
|
EQUIPAGE
|
TSC Does Not Support Command
|
FNCR
|
FAULT
|
NE Failure - Circuit Restored to Last Condition - Monitor or Terminate
|
FNDT
|
FAULT
|
No Dial Tone Detected
|
FNEC
|
FAULT
|
NTE Has Lost 8-KHZ Byte Clock
|
FNSC
|
FAULT
|
NTE Has Lost 16-KHZ Byte Clock
|
FRCE
|
FAULT
|
RTU Component or Configuration Error
|
FRDA
|
FAULT
|
RTU Does Not Answer the Call
|
FREC
|
FAULT
|
RTU Eight KHZ Byte Clock Lost
|
FRNR
|
FAULT
|
RTU Does Not Reply
|
IBEX
|
INPUT
|
Block Extra
|
IBMS
|
INPUT
|
Block Missing
|
IBNC
|
INPUT
|
Block Not Consistent
|
ICNV
|
INPUT
|
Command Not Valid
|
IDMS
|
INPUT
|
Data Missing
|
IDNC
|
INPUT
|
Data Not Consistent
|
IDNV
|
INPUT
|
Data Not Valid
|
IDRG
|
INPUT
|
Data Range Error
|
IIAC
|
INPUT
|
Invalid Access Identifier (AID)
|
IICM
|
INPUT
|
Invalid Command
|
IICT
|
INPUT
|
Invalid Correlation Tag
|
IIDT
|
INPUT
|
Invalid Data Parameter
|
IIFM
|
INPUT
|
Invalid Data Format
|
IIPG
|
INPUT
|
Invalid Parameter Grouping
|
IISP
|
INPUT
|
Invalid Syntax or Punctuation
|
IITA
|
INPUT
|
Invalid Target Identifier
|
INAC
|
INPUT
|
Access Number Not Correct
|
INUP
|
INPUT
|
Non-Null Unimplemented Parameter
|
IPEX
|
INPUT
|
Parameter Extra
|
IPMS
|
INPUT
|
Parameter Missing
|
IPNC
|
INPUT
|
Parameter Not Consistent
|
IPNV
|
INPUT
|
Parameter Not Valid
|
ISCH
|
INPUT
|
Syntax Invalid Character
|
ISPC
|
INPUT
|
Syntax Punctuation
|
ITSN
|
INPUT
|
Invalid/Inactive Test Session Number
|
PICC
|
PRIVILEGE
|
Illegal Command Code
|
PIMA
|
PRIVILEGE
|
Invalid Memory Address
|
PIMF
|
PRIVILEGE
|
Invalid Memory File
|
PIUC
|
PRIVILEGE
|
Illegal Privilege Code
|
PLNA
|
PRIVILEGE
|
Login Not Active
|
RABY
|
RESOURCE
|
All Taps Busy
|
RALB
|
RESOURCE
|
All Units of Requested Type are Busy
|
RANB
|
RESOURCE
|
Access Network Busy
|
RCBY
|
RESOURCE
|
Circuit Busy
|
RCIN
|
RESOURCE
|
Requested Circuit ID Does Not Exist
|
RNAN
|
RESOURCE
|
Requested NE Access Number Does Not Exist
|
RNAU
|
RESOURCE
|
Requested NE Access Number Unassigned
|
RNBY
|
RESOURCE
|
NE is Busy
|
RRCP
|
RESOURCE
|
Unit Specified by Routing Code Busy
|
RRNG
|
RESOURCE
|
Requested Changes Exceeds Range
|
RTBY
|
RESOURCE
|
Requested Tap Busy
|
RTEN
|
RESOURCE
|
Requested Tab Does Not Exist
|
RTUB
|
RESOURCE
|
Test Unit Busy
|
SAAL
|
STATUS
|
Already Allowed
|
SAAS
|
STATUS
|
Already Assigned
|
SABT
|
STATUS
|
Aborted
|
SACS
|
STATUS
|
Access Unit Cannot Sync on Facility Signal
|
SADC
|
STATUS
|
Already Disconnected
|
SADS
|
STATUS
|
Access Unit in Diagnostic State
|
SAIN
|
STATUS
|
Already Inhibited
|
SAIS
|
STATUS
|
Already In-Service
|
SAMS
|
STATUS
|
Already in Maintenance State
|
SAOP
|
STATUS
|
Already Operated
|
SAOS
|
STATUS
|
Already Out-of-Service
|
SAPF
|
STATUS
|
Access Path Continuity Check Failed
|
SAPR
|
STATUS
|
Already in Protection State
|
SARB
|
STATUS
|
All Resources Busy
|
SATF
|
STATUS
|
Automatic Test Failed
|
SCAT
|
STATUS
|
Circuit is Already Connected to Another Tap
|
SCBS
|
STATUS
|
Channel Busy
|
SCIS
|
STATUS
|
Circuit in Split Condition
|
SCNA
|
STATUS
|
Command Not Able to be Aborted
|
SCNF
|
STATUS
|
Command Not Found
|
SCNS
|
STATUS
|
Circuit Not in Split Condition
|
SCOS
|
STATUS
|
Channel Out-of-Service
|
SCSD
|
STATUS
|
Can't Split DS0B Circuit
|
SCSN
|
STATUS
|
Invalid Command Sequence
|
SDAS
|
STATUS
|
Diagnosis Already Started
|
SDBE
|
STATUS
|
Internal Data Base Error
|
SDFA
|
STATUS
|
Duplex Unit Failed
|
SDLD
|
STATUS
|
Duplex Unit Locked
|
SDNA
|
STATUS
|
Dumple Unit Not Available
|
SDNC
|
STATUS
|
Input Data is Not Consistent With NE Data
|
SDNR
|
STATUS
|
Data Not Ready
|
SDNS
|
STATUS
|
Diagnosis Not Started Yet
|
SEOS
|
STATUS
|
NTE is Out-of-Service
|
SFAS
|
STATUS
|
Fault Locating Already Started
|
SFNS
|
STATUS
|
Fault Locating Not Started yet
|
SFYA
|
STATUS
|
Facility Reports Yellow Alarm
|
SLNS
|
STATUS
|
Log Not Started Yet
|
SLOS
|
STATUS
|
TSC to RTU Link Out-of-Service
|
SNCC
|
STATUS
|
Not Cross-Connected
|
SNCN
|
STATUS
|
NTE Unable to Execute Command
|
SNDS
|
STATUS
|
NTE is in a Diagnostic State
|
SNIM
|
STATUS
|
NTE Access Complete, Circuit was in Monitor State
|
SNIS
|
STATUS
|
Not in Service
|
SNML
|
STATUS
|
No Monitor Line Established
|
SNNB
|
STATUS
|
NTE Could Not Sync on DS0B Signal
|
SNNS
|
STATUS
|
NTE Could Not Sync on DS-1 Signal
|
SNOS
|
STATUS
|
NTE is Out-of-Service
|
SNPR
|
STATUS
|
Not in Protection State
|
SNRM
|
STATUS
|
System Not in Restoration Mode
|
SNRS
|
STATUS
|
Not Reserved
|
SNSR
|
STATUS
|
No Switch Request Outstanding
|
SNVS
|
STATUS
|
Not in Valid State
|
SNYA
|
STATUS
|
NTE has Detected a Yellow Alarm
|
SOSE
|
STATUS
|
Operating System Error
|
SOST
|
STATUS
|
Out-of-Service, Testing
|
SPFA
|
STATUS
|
Protection Unit Failed
|
SPLD
|
STATUS
|
Protection Unit Locked
|
SPNA
|
STATUS
|
Process Not Able to be Aborted
|
SPNF
|
STATUS
|
Process Not Found
|
SRAC
|
STATUS
|
Requested Access Configuration is Invalid
|
SRAN
|
STATUS
|
Unable to Release Access System
|
SRCI
|
STATUS
|
Requested Command(s) Inhibited
|
SRCN
|
STATUS
|
Requested Condition Already Exists
|
SROF
|
STATUS
|
Requested Operation Failed
|
SROS
|
STATUS
|
Required RTU Out of Service
|
SRQN
|
STATUS
|
Invalid Request
|
SRTN
|
STATUS
|
Unable to Release Tap
|
SRTO
|
STATUS
|
Reply Timeout Occurred
|
SSCE
|
STATUS
|
Systemic (SNIDER) Communications Error
|
SSNG
|
STATUS
|
Subrate Selected is Incorrect
|
SSNP
|
STATUS
|
Speed Selected is Incorrect
|
SSNQ
|
STATUS
|
Test Signal Not QRS
|
SSRD
|
STATUS
|
Switch Request Denied
|
SSRE
|
STATUS
|
System Resources Exceeded
|
STAB
|
STATUS
|
Test Aborted
|
STLC
|
STATUS
|
Tap Unable to Locate Channel
|
STNO
|
STATUS
|
TSC/RTU to TAU Link Out of service
|
STOS
|
STATUS
|
Test Access Unit Out of Service
|
STTI
|
STATUS
|
Tap Idle
|
SWFA
|
STATUS
|
Working Unit Failed
|
SWLD
|
STATUS
|
Working Unit Locked
|
11.15 Echo
In order to improve telnet functionality for automated systems, the echo function was been turned off in Release 2.1.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.
To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON.