cc/td/doc/product/ong/15327/r34userd
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Network Element Defaults

Network Element Defaults Description

NTP-B164 Edit Network Element Defaults

NTP-B165 Import Network Element Defaults

NTP-B166 Export Network Element Defaults

Card Default Settings

Node Default Settings


Network Element Defaults


This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15327. It includes descriptions of card default settings and node default settings and provides procedures for importing, exporting and editing the settings. Ethernet card settings are not included in the factory-configured settings.

To change card settings individually (that is, without changing the defaults), see "Change Port Settings." To change node settings without changing the defaults, see "Change Node Settings."

Network Element Defaults Description

The NE defaults are pre-installed on each ONS 15327 XTC card. They also ship as a file called 15327-defaults.txt on the CTC software CD in the event you want to import the defaults onto existing XTC cards. The NE defaults include card-level and node-level defaults.

Changes made manually using "Change Port Settings"override the default settings. If you use the Defaults Editor or import a new defaults file, that is, if defaults are changed, the changes apply only to cards installed or to slots pre-provisioned after the manual changes were made. A new defaults file will not take effect for cards already installed or ports slots already pre-provisioned when the change takes place.

Changes made manually to the node-level default settings (either when you initially turn up a node or change node settings later) override the default settings. If you change the default settings using the Defaults Editor or by importing a new defaults file, the new defaults take effect immediately for all settings except those relating to UPSR, BLSR, or 1+1 protection.

Use the following procedures if you need to edit, import, or export NE defaults.

NTP-B164 Edit Network Element Defaults

Purpose

This procedure edits the NE defaults using the NE Defaults Editor. The new defaults can either be applied only to the login node or exported to a file and imported for use on other nodes.

Tools/Equipment

None

Prerequisite Procedures

None

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Superuser only



Step 1 Complete the "DLP-B60 Log into CTC" task. If you are already logged in, continue with Step 2.

Step 2 Click the Provisioning > Defaults Editor tabs.

Step 3 In the Defaults Selector area, choose a card (if you are editing card-level defaults) or NODE (if you are editing node-level defaults). Click the node name at the top of the Defaults Selector column to list all available NE defaults under Property Name.

Step 4 Locate a default you want to change under Property Name.

Step 5 Click the Default Value column for the default property you are changing and choose a value from the drop-down menu (available for some node-level settings only), or type the new value. You can modify multiple default values before applying the changes.


Note If you click Reset before you click Apply, all values will return to their original settings.


Step 6 Click Apply.


Note If the property is unavailable, click the Property Name column to activate the Apply button.


Step 7 Click Yes on the conformation dialog box. The dialog box appears if you are modifying node-level defaults; it notifies you that applying defaults for node level attributes overrides current provisioning.


Note Changes to node settings take effect when you click Apply. Changes to the IIOP Listener Port setting reboots the XTC. Changes made to card settings using the Defaults Editor do not change the settings for cards that are currently installed or slots that are pre-provisioned for cards. Card settings must be manually changed using procedures in "Change Port Settings."


Stop. You have completed this procedure.


NTP-B165 Import Network Element Defaults

Purpose

This procedure imports the NE defaults using the NE Defaults Editor. The defaults can either be imported from the CTC software CD (factory defaults) or from a customized file exported and saved from a node.

Tools/Equipment

None

Prerequisite Procedures

None

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Superuser only



Step 1 Complete the "DLP-B60 Log into CTC" task. If you are already logged in, continue with Step 2.

Step 2 Click the Provisioning > Defaults Editor tabs.

Step 3 Click Import.

Step 4 If the correct file name and location do not appear in the Import Defaults from File dialog box, click Browse and browse to the file you are importing.

Step 5 When the correct file name and location appear in the dialog box (the correct file name is 15327-defaults.txt if you are importing the factory defaults), click OK.

A pencil icon will appear next to any default value that will be changed as a result of importing the new defaults file.

Step 6 Click Apply.

Step 7 Click Yes on the confirmation dialog box. The dialog box appears if you are modifying node-level defaults; it notifies you that applying defaults for node level attributes overrides current provisioning.


Note Changes to node settings take effect when you click Apply. Changes to the IIOP Listener Port setting reboots the XTC. Changes made to card settings using the Defaults Editor do not change the settings for cards that are currently installed or slots that are pre-provisioned for cards. Card settings must be manually changed by using the procedures in "Change Port Settings."


Stop. You have completed this procedure.


NTP-B166 Export Network Element Defaults

Purpose

This procedure exports the NE defaults using the NE Defaults Editor. The exported defaults can be imported to other nodes.

Tools/Equipment

None

Prerequisite Procedures

None

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Superuser only



Step 1 Complete the "DLP-B60 Log into CTC" task. If you are already logged in, continue with Step 2.

Step 2 Click the Provisioning > Defaults Editor tabs.

Step 3 Click Export.

Step 4 If the file it does not appear in the Export Defaults to File dialog box, Click Browse and browse to the location where you want to export the file

Step 5 Change the file name to something easy to remember (the file name has no extension).

Step 6 Click OK.

Stop. You have completed this procedure.


Card Default Settings

The tables in this section list the default settings for each card. Cisco provides the following settings pre-provisioned for the ONS 15327 optical cards and electrical ports:

Soak Time (all cards) is the length of time that elapses between an AINS port receiving a valid signal and when it automatically changes to in-service status.

Line Coding (DS-1 ports) defines the DS-1 transmission coding type that is used.

Line Length (DS-1 ports) defines the distance (in feet) from the backplane connection to the next termination point.

Line Type (DS-1 ports) defines the type of framing used.

Port State (all cards) sets the port to one of the four available states (IS, OOS, OOS_MT, or OOS_AINS), depending on whether you need ports in or out of service. Refer to the Cisco ONS 15327 Reference Manual for a complete description of the port states.

SF BER Level (OC-N cards) defines the signal fail bit error rate.

SD BER Level (OC-N cards) defines the signal degrade bit error rate.

Enable Synch Messages (OC-N cards) enables synchronization status messages (S1 byte), which allow the node to choose the best timing source.

STS IPPM Enabled (OC-N cards) enables intermediate-path performance monitoring on a node for transparent monitoring of a channel that does not terminate on that node.

Send Do Not Use (OC-N cards) sends a DUS message on the S1 byte when enabled.

PM Threshold Settings (all cards) set the performance monitoring parameters for gathering performance data and detecting problems early.

Table C-1 lists the DS-1 default settings.

Table C-1 DS-1 Default Settings 

Property Name
Default Value

XTCDS1.config.AINSSoakTime

08:00 (hours:mins)

XTCDS1.config.LineCoding

AMI

XTCDS1.config.LineLength

0-131 (feet)

XTCDS1.config.LineType

D4

XTCDS1XTCDS1.config.State

OOS

XTCDS1.pmthresholds.line.farend.15min.ES

65 (seconds)

XTCDS1.pmthresholds.line.farend.1day.ES

648 (seconds)

XTCDS1.pmthresholds.line.nearend.15min.CV

13340 (BPV count)

XTCDS1.pmthresholds.line.nearend.15min.ES

65 (seconds)

XTCDS1.pmthresholds.line.nearend.15min.LOSS

10 (seconds)

XTCDS1.pmthresholds.line.nearend.15min.SES

10 (seconds)

XTCDS1.pmthresholds.line.nearend.1day.CV

133400 (BPV count)

XTCDS1.pmthresholds.line.nearend.1day.ES

648 (seconds)

XTCDS1.pmthresholds.line.nearend.1day.LOSS

10 (seconds)

XTCDS1.pmthresholds.line.nearend.1day.SES

100 (seconds)

XTCDS1.pmthresholds.path.farend.15min.CSS

25 (seconds)

XTCDS1.pmthresholds.path.farend.15min.CV

13296 (BIP count)

XTCDS1.pmthresholds.path.farend.15min.ES

65 (seconds)

XTCDS1.pmthresholds.path.farend.15min.ESA

25 (seconds)

XTCDS1.pmthresholds.path.farend.15min.ESB

25 (seconds)

XTCDS1.pmthresholds.path.farend.15min.SEFS

25 (seconds)

XTCDS1.pmthresholds.path.farend.15min.SES

10 (seconds)

XTCDS1.pmthresholds.path.farend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.path.farend.1day.CSS

25 (seconds)

XTCDS1.pmthresholds.path.farend.1day.CV

132960 (BIP count)

XTCDS1.pmthresholds.path.farend.1day.ES

648 (seconds)

XTCDS1.pmthresholds.path.farend.1day.ESA

25 (seconds)

XTCDS1.pmthresholds.path.farend.1day.ESB

25 (seconds)

XTCDS1.pmthresholds.path.farend.1day.SEFS

25 (seconds)

XTCDS1.pmthresholds.path.farend.1day.SES

100 (seconds)

XTCDS1.pmthresholds.path.farend.1day.UAS

10 (seconds)

XTCDS1.pmthresholds.path.nearend.15min.AISS

10 (seconds)

XTCDS1.pmthresholds.path.nearend.15min.CV

13296 (BIP count)

XTCDS1.pmthresholds.path.nearend.15min.ES

65 (seconds)

XTCDS1.pmthresholds.path.nearend.15min.SAS

2 (seconds)XTCDS3

XTCDS1.pmthresholds.path.nearend.15min.SES

10 (seconds)

XTCDS1.pmthresholds.path.nearend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.path.nearend.1day.AISS

10 (seconds)

XTCDS1.pmthresholds.path.nearend.1day.CV

132960 (BIP count)

XTCDS1.pmthresholds.path.nearend.1day.ES

648 (seconds)

XTCDS1.pmthresholds.path.nearend.1day.SAS

17 (seconds)

XTCDS1.pmthresholds.path.nearend.1day.SES

100 (seconds)

XTCDS1.pmthresholds.path.nearend.1day.UAS

10 (seconds)

XTCDS1.pmthresholds.sts.farend.15min.CV

15 (B3 count)

XTCDS1.pmthresholds.sts.farend.15min.ES

12 (seconds)

XTCDS1.pmthresholds.sts.farend.15min.FC

10 (count)

XTCDS1.pmthresholds.sts.farend.15min.SES

3 (seconds)

XTCDS1.pmthresholds.sts.farend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.sts.farend.1day.CV

125 (B3 count)

XTCDS1.pmthresholds.sts.farend.1day.ES

100 (seconds)

XTCDS1.pmthresholds.sts.farend.1day.FC

10 (count)

XTCDS1.pmthresholds.sts.farend.1day.SES

7 (seconds)

XTCDS1.pmthresholds.sts.farend.1day.UAS

10 (seconds)

XTCDS1.pmthresholds.sts.nearend.15min.CV

15 (B3 count)

XTCDS1.pmthresholds.sts.nearend.15min.ES

12 (seconds)

XTCDS1.pmthresholds.sts.nearend.15min.FC

10 (count)

XTCDS1.pmthresholds.sts.nearend.15min.SES

3 (seconds)

XTCDS1.pmthresholds.sts.nearend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.sts.nearend.1day.CV

125 (B3 count)

XTCDS1.pmthresholds.sts.nearend.1day.ES

100 (seconds)

XTCDS1.pmthresholds.sts.nearend.1day.FC

10 (count)

XTCDS1.pmthresholds.sts.nearend.1day.SES

7 (seconds)

XTCDS1.pmthresholds.sts.nearend.1day.UAS

10 (seconds)

XTCDS1.pmthresholds.vt.farend.15min.CV

15 (BIP8 count)

XTCDS1.pmthresholds.vt.farend.15min.ES

12 (seconds)

XTCDS1.pmthresholds.vt.farend.15min.SES

3 (seconds)

XTCDS1.pmthresholds.vt.farend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.vt.farend.1day.CV

125 (BIP8 count)

XTCDS1.pmthresholds.vt.farend.1day.ES

100 (seconds)

XTCDS1.pmthresholds.vt.farend.1day.SES

7 (seconds)

XTCDS1.pmthresholds.vt.farend.1day.UAS

10 (seconds)

XTCDS1.pmthresholds.vt.nearend.15min.CV

15 (BIP8 count)

XTCDS1.pmthresholds.vt.nearend.15min.ES

12 (seconds)

XTCDS1.pmthresholds.vt.nearend.15min.SES

3 (seconds)

XTCDS1.pmthresholds.vt.nearend.15min.UAS

10 (seconds)

XTCDS1.pmthresholds.vt.nearend.1day.CV

125 (BIP8 count)

XTCDS1.pmthresholds.vt.nearend.1day.ES

100 (seconds)

XTCDS1.pmthresholds.vt.nearend.1day.SES

7 (seconds)

XTCDS1.pmthresholds.vt.nearend.1day.UAS

10 (seconds)


Table C-2 lists the DS-3 default settings.

Table C-2 DS-3 Default Settings 

Property Name
Default Value

XTCDS3.config.AINSSoakTime

08:00 (hours:mins)

XTCDS3.config.LineLength

0-225 (feet)

XTCDS3.config.State

OOS

XTCDS3.pmthresholds.line.nearend.15min.CV

387 (BPV count)

XTCDS3.pmthresholds.line.nearend.15min.ES

25 (seconds)

XTCDS3.pmthresholds.line.nearend.15min.LOSS

10 (seconds)

XTCDS3.pmthresholds.line.nearend.15min.SES

4 (seconds)

XTCDS3.pmthresholds.line.nearend.1day.CV

3865 (BPV count)

XTCDS3.pmthresholds.line.nearend.1day.ES

250 (seconds)

XTCDS3.pmthresholds.line.nearend.1day.LOSS

10 (seconds)

XTCDS3.pmthresholds.line.nearend.1day.SES

40 (seconds)

XTCDS3.pmthresholds.sts.farend.15min.CV

15 (G1 count)

XTCDS3.pmthresholds.sts.farend.15min.ES

12 (seconds)

XTCDS3.pmthresholds.sts.farend.15min.FC

10 (count)

XTCDS3.pmthresholds.sts.farend.15min.SES

3 (seconds)

XTCDS3.pmthresholds.sts.farend.15min.UAS

10 (seconds)

XTCDS3.pmthresholds.sts.farend.1day.CV

125 (G1 count)

XTCDS3.pmthresholds.sts.farend.1day.ES

100 (seconds)

XTCDS3.pmthresholds.sts.farend.1day.FC

10 (count)

XTCDS3.pmthresholds.sts.farend.1day.SES

7 (seconds)

XTCDS3.pmthresholds.sts.farend.1day.UAS

10 (seconds)

XTCDS3.pmthresholds.sts.nearend.15min.CV

15 (B3 count)

XTCDS3.pmthresholds.sts.nearend.15min.ES

12 (seconds)

XTCDS3.pmthresholds.sts.nearend.15min.FC

10 (count)

XTCDS3.pmthresholds.sts.nearend.15min.SES

3 (seconds)

XTCDS3.pmthresholds.sts.nearend.15min.UAS

10 (seconds)

XTCDS3.pmthresholds.sts.nearend.1day.CV

125 (B3 count)

XTCDS3.pmthresholds.sts.nearend.1day.ES

100 (seconds)

XTCDS3.pmthresholds.sts.nearend.1day.FC

10 (count)

XTCDS3.pmthresholds.sts.nearend.1day.SES

7 (seconds)

XTCDS3.pmthresholds.sts.nearend.1day.UAS

10 (seconds)


Table C-3 lists the default settings for the OC-3 card.

Table C-3 OC-3 Card Default Settings  

Property Name
Default Value

OC3.config.line.AINSSoakTime

08:00 (hours:mins)

OC3.config.line.EnableSyncMsg

TRUE

OC3.config.line.PJStsMon#

0 (STS #)

OC3.config.line.SDBER

1E-7

OC3.config.line.SFBER

1E-4

OC3.config.line.SendDoNotUse

FALSE

OC3.config.line.State

OOS

OC3.config.sts.IPPMEnabled

FALSE

OC3.pmthresholds.line.farend.15min.CV

1312 (B2 count)

OC3.pmthresholds.line.farend.15min.ES

87 (seconds)

OC3.pmthresholds.line.farend.15min.FC

10 (count)

OC3.pmthresholds.line.farend.15min.SES

1 (seconds)

OC3.pmthresholds.line.farend.15min.UAS

3 (seconds)

OC3.pmthresholds.line.farend.1day.CV

13120 (B2 count)

OC3.pmthresholds.line.farend.1day.ES

864 (seconds)

OC3.pmthresholds.line.farend.1day.FC

40 (count)

OC3.pmthresholds.line.farend.1day.SES

4 (seconds)

OC3.pmthresholds.line.farend.1day.UAS

10 (seconds)

OC3.pmthresholds.line.nearend.15min.CV

1312 (B2 count)

OC3.pmthresholds.line.nearend.15min.ES

87 (seconds)

OC3.pmthresholds.line.nearend.15min.FC

10 (count)

OC3.pmthresholds.line.nearend.15min.NPJC-PDET

60 (count)

OC3.pmthresholds.line.nearend.15min.NPJC-PGEN

60 (count)

OC3.pmthresholds.line.nearend.15min.PPJC-PDET

60 (count)

OC3.pmthresholds.line.nearend.15min.PPJC-PGEN

60 (count)

OC3.pmthresholds.line.nearend.15min.PSC

1 (count)

OC3.pmthresholds.line.nearend.15min.PSD

300 (seconds)

OC3.pmthresholds.line.nearend.15min.SES

1 (seconds)

OC3.pmthresholds.line.nearend.15min.UAS

3 (seconds)

OC3.pmthresholds.line.nearend.1day.CV

13120 (B2 count)

OC3.pmthresholds.line.nearend.1day.ES

864 (seconds)

OC3.pmthresholds.line.nearend.1day.FC

40 (count)

OC3.pmthresholds.line.nearend.1day.NPJC-PDET

5760 (count)

OC3.pmthresholds.line.nearend.1day.NPJC-PGEN

5760 (count)

OC3.pmthresholds.line.nearend.1day.PPJC-PDET

5760 (count)

OC3.pmthresholds.line.nearend.1day.PPJC-PGEN

5760 (count)

OC3.pmthresholds.line.nearend.1day.PSC

5 (count)

OC3.pmthresholds.line.nearend.1day.PSD

600 (seconds)

OC3.pmthresholds.line.nearend.1day.SES

4 (seconds)

OC3.pmthresholds.line.nearend.1day.UAS

10 (seconds)

OC3.pmthresholds.section.nearend.15min.CV

1000 (B1 count)

OC3.pmthresholds.section.nearend.15min.ES

500 (seconds)

OC3.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

OC3.pmthresholds.section.nearend.15min.SES

500 (seconds)

OC3.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

OC3.pmthresholds.section.nearend.1day.ES

5000 (seconds)

OC3.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

OC3.pmthresholds.section.nearend.1day.SES

5000 (seconds)

OC3.pmthresholds.sts.nearend.15min.CV

15 (B3 count)

OC3.pmthresholds.sts.nearend.15min.ES

12 (seconds)

OC3.pmthresholds.sts.nearend.15min.FC

10 (count)

OC3.pmthresholds.sts.nearend.15min.SES

3 (seconds)

OC3.pmthresholds.sts.nearend.15min.UAS

10 (seconds)

OC3.pmthresholds.sts.nearend.1day.CV

125 (B3 count)

OC3.pmthresholds.sts.nearend.1day.ES

100 (seconds)

OC3.pmthresholds.sts.nearend.1day.FC

10 (count)

OC3.pmthresholds.sts.nearend.1day.SES

7 (seconds)

OC3.pmthresholds.sts.nearend.1day.UAS

10 (seconds)


Table C-4 lists the default settings for the OC-12 card.

Table C-4 OC-12 Card Default Settings  

Property Name
Default Value

OC12.config.line.AINSSoakTime

08:00 (hours:mins)

OC12.config.line.EnableSyncMsg

TRUE

OC12.config.line.PJStsMon#

0 (STS #)

OC12.config.line.SDBER

1E-7

OC12.config.line.SFBER

1E-4

OC12.config.line.SendDoNotUse

FALSE

OC12.config.line.State

OOS

OC12.config.sts.IPPMEnabled

FALSE

OC12.pmthresholds.line.farend.15min.CV

5315 (B2 count)

OC12.pmthresholds.line.farend.15min.ES

87 (seconds)

OC12.pmthresholds.line.farend.15min.FC

10 (count)

OC12.pmthresholds.line.farend.15min.SES

1 (seconds)

OC12.pmthresholds.line.farend.15min.UAS

3 (seconds)

OC12.pmthresholds.line.farend.1day.CV

53150 (B2 count)

OC12.pmthresholds.line.farend.1day.ES

864 (seconds)

OC12.pmthresholds.line.farend.1day.FC

40 (count)

OC12.pmthresholds.line.farend.1day.SES

4 (seconds)

OC12.pmthresholds.line.farend.1day.UAS

10 (seconds)

OC12.pmthresholds.line.nearend.15min.CV

5315 (B2 count)

OC12.pmthresholds.line.nearend.15min.ES

87 (seconds)

OC12.pmthresholds.line.nearend.15min.FC

10 (count)

OC12.pmthresholds.line.nearend.15min.NPJC-PDET

60 (count)

OC12.pmthresholds.line.nearend.15min.NPJC-PGEN

60 (count)

OC12.pmthresholds.line.nearend.15min.PPJC-PDET

60 (count)

OC12.pmthresholds.line.nearend.15min.PPJC-PGEN

60 (count)

OC12.pmthresholds.line.nearend.15min.PSC

1 (count)

OC12.pmthresholds.line.nearend.15min.PSC-W

1 (count)

OC12.pmthresholds.line.nearend.15min.PSD

300 (seconds)

OC12.pmthresholds.line.nearend.15min.PSD-W

300 (seconds)

OC12.pmthresholds.line.nearend.15min.SES

1 (seconds)

OC12.pmthresholds.line.nearend.15min.UAS

3 (seconds)

OC12.pmthresholds.line.nearend.1day.CV

53150 (B2 count)

OC12.pmthresholds.line.nearend.1day.ES

864 (seconds)

OC12.pmthresholds.line.nearend.1day.FC

40 (count)

OC12.pmthresholds.line.nearend.1day.NPJC-PDET

5760 (count)

OC12.pmthresholds.line.nearend.1day.NPJC-PGEN

5760 (count)

OC12.pmthresholds.line.nearend.1day.PPJC-PDET

5760 (count)

OC12.pmthresholds.line.nearend.1day.PPJC-PGEN

5760 (count)

OC12.pmthresholds.line.nearend.1day.PSC

5 (count)

OC12.pmthresholds.line.nearend.1day.PSC-W

5 (count)

OC12.pmthresholds.line.nearend.1day.PSD

600 (seconds)

OC12.pmthresholds.line.nearend.1day.PSD-W

600 (seconds)

OC12.pmthresholds.line.nearend.1day.SES

4 (seconds)

OC12.pmthresholds.line.nearend.1day.UAS

10 (seconds)

OC12.pmthresholds.section.nearend.15min.CV

1000 (B1 count)

OC12.pmthresholds.section.nearend.15min.ES

500 (seconds)

OC12.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

OC12.pmthresholds.section.nearend.15min.SES

500 (seconds)

OC12.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

OC12.pmthresholds.section.nearend.1day.ES

5000 (seconds)

OC12.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

OC12.pmthresholds.section.nearend.1day.SES

5000 (seconds)

OC12.pmthresholds.sts.nearend.15min.CV

15 (B3 count)

OC12.pmthresholds.sts.nearend.15min.ES

12 (seconds)

OC12.pmthresholds.sts.nearend.15min.FC

10 (count)

OC12.pmthresholds.sts.nearend.15min.SES

3 (seconds)

OC12.pmthresholds.sts.nearend.15min.UAS

10 (seconds)

OC12.pmthresholds.sts.nearend.1day.CV

125 (B3 count)

OC12.pmthresholds.sts.nearend.1day.ES

100 (seconds)

OC12.pmthresholds.sts.nearend.1day.FC

10 (count)

OC12.pmthresholds.sts.nearend.1day.SES

7 (seconds)

OC12.pmthresholds.sts.nearend.1day.UAS

10 (seconds)


Table C-5 lists the default settings for the OC-48 cards.

Table C-5 OC-48 Cards Default Settings 

Property Name
Default Value

OC48.config.line.AINSSoakTime

08:00 (hours:mins)

OC48.config.line.EnableSyncMsg

TRUE

OC48.config.line.PJStsMon#

0 (STS #)

OC48.config.line.SDBER

1E-7

OC48.config.line.SFBER

1E-4

OC48.config.line.SendDoNotUse

FALSE

OC48.config.line.State

OOS

OC48.config.sts.IPPMEnabled

FALSE

OC48.pmthresholds.line.farend.15min.CV

21260 (B2 count)

OC48.pmthresholds.line.farend.15min.ES

87 (seconds)

OC48.pmthresholds.line.farend.15min.FC

10 (count)

OC48.pmthresholds.line.farend.15min.SES

1 (seconds)

OC48.pmthresholds.line.farend.15min.UAS

3 (seconds)

OC48.pmthresholds.line.farend.1day.CV

212600 (B2 count)

OC48.pmthresholds.line.farend.1day.ES

864 (seconds)

OC48.pmthresholds.line.farend.1day.FC

40 (count)

OC48.pmthresholds.line.farend.1day.SES

4 (seconds)

OC48.pmthresholds.line.farend.1day.UAS

10 (seconds)

OC48.pmthresholds.line.nearend.15min.CV

21260 (B2 count)

OC48.pmthresholds.line.nearend.15min.ES

87 (seconds)

OC48.pmthresholds.line.nearend.15min.FC

10 (count)

OC48.pmthresholds.line.nearend.15min.NPJC-PDET

60 (count)

OC48.pmthresholds.line.nearend.15min.NPJC-PGEN

60 (count)

OC48.pmthresholds.line.nearend.15min.PPJC-PDET

60 (count)

OC48.pmthresholds.line.nearend.15min.PPJC-PGEN

60 (count)

OC48.pmthresholds.line.nearend.15min.PSC

1 (count)

OC48.pmthresholds.line.nearend.15min.PSC-R

1 (count)

OC48.pmthresholds.line.nearend.15min.PSC-S

1 (count)

OC48.pmthresholds.line.nearend.15min.PSC-W

1 (count)

OC48.pmthresholds.line.nearend.15min.PSD

300 (seconds)

OC48.pmthresholds.line.nearend.15min.PSD-R

300 (seconds)

OC48.pmthresholds.line.nearend.15min.PSD-S

300 (seconds)

OC48.pmthresholds.line.nearend.15min.PSD-W

300 (seconds)

OC48.pmthresholds.line.nearend.15min.SES

1 (seconds)

OC48.pmthresholds.line.nearend.15min.UAS

3 (seconds)

OC48.pmthresholds.line.nearend.1day.CV

212600 (B2 count)

OC48.pmthresholds.line.nearend.1day.ES

864 (seconds)

OC48.pmthresholds.line.nearend.1day.FC

40 (count)

OC48.pmthresholds.line.nearend.1day.NPJC-PDET

5760 (count)

OC48.pmthresholds.line.nearend.1day.NPJC-PGEN

5760 (count)

OC48.pmthresholds.line.nearend.1day.PPJC-PDET

5760 (count)

OC48.pmthresholds.line.nearend.1day.PPJC-PGEN

5760 (count)

OC48.pmthresholds.line.nearend.1day.PSC

5 (count)

OC48.pmthresholds.line.nearend.1day.PSC-R

5 (count)

OC48.pmthresholds.line.nearend.1day.PSC-S

5 (count)

OC48.pmthresholds.line.nearend.1day.PSC-W

5 (count)

OC48.pmthresholds.line.nearend.1day.PSD

600 (seconds)

OC48.pmthresholds.line.nearend.1day.PSD-R

600 (seconds)

OC48.pmthresholds.line.nearend.1day.PSD-S

600 (seconds)

OC48.pmthresholds.line.nearend.1day.PSD-W

600 (seconds)

OC48.pmthresholds.line.nearend.1day.SES

4 (seconds)

OC48.pmthresholds.line.nearend.1day.UAS

10 (seconds)

OC48.pmthresholds.section.nearend.15min.CV

10000 (B1 count)

OC48.pmthresholds.section.nearend.15min.ES

500 (seconds)

OC48.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

OC48.pmthresholds.section.nearend.15min.SES

500 (seconds)

OC48.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

OC48.pmthresholds.section.nearend.1day.ES

5000 (seconds)

OC48.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

OC48.pmthresholds.section.nearend.1day.SES

5000 (seconds)

OC48.pmthresholds.sts.nearend.15min.CV

15 (B3 count)

OC48.pmthresholds.sts.nearend.15min.ES

12 (seconds)

OC48.pmthresholds.sts.nearend.15min.FC

10 (count)

OC48.pmthresholds.sts.nearend.15min.SES

3 (seconds)

OC48.pmthresholds.sts.nearend.15min.UAS

10 (seconds)

OC48.pmthresholds.sts.nearend.1day.CV

125 (B3 count)

OC48.pmthresholds.sts.nearend.1day.ES

100 (seconds)

OC48.pmthresholds.sts.nearend.1day.FC

10 (count)

OC48.pmthresholds.sts.nearend.1day.SES

7 (seconds)

OC48.pmthresholds.sts.nearend.1day.UAS

10 (seconds)


Node Default Settings

The table in this section lists the node-level default settings for the Cisco ONS 15327. Cisco provides the following types of settings pre-provisioned for each ONS 15327 node:

UPSR reversion settings determine whether or not UPSR circuits are revertive and, if so, what the reversion time is.

Defaults Description lists the current defaults file on the node.

BLSR reversion settings determine whether or not BLSR circuits are revertive and, if so, what the reversion time is.

IIOP Listener Port sets the IIOP listener port number.

Login Warning Message warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.

1+1 protection settings determine whether or not 1+1 protected circuits are revertive and, if so, what the reversion time is.

Timing settings determine the AIS threshold, coding, and framing for BITS1 and BITS2 timing.

Table C-6 lists the ONS 15327 node default settings.

Table C-6 Node Default Settings 

Property Name
Default Value

NODE.circuits.CreateLikeTL1

FALSE

NODE.circuits.upsr.SDBER

1E-6

NODE.circuits.upsr.SFBER

1E-4

NODE.circuits.upsr.SwitchOnPDIP

FALSE

NODE.circuits.upsr.ReversionTime

5.0 (minutes)

NODE.circuits.upsr.Revertive

FALSE

NODE.general.CraftAccessOnly

FALSE

NODE.general.CtcIpDisplaySuppression

FALSE

NODE.general.DefaultsDescription

Factory Defaults

NODE.general.EnableFirewall

FALSE

NODE.general.EnableProxy

FALSE

NODE.general.IIOPListenerPort (reboots node)

57790 (port #)

NODE.general.LoginWarningMessage

LoginWarningMessage=<center><B>WARNING</B><center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p> and security reasons. By proceeding, you consent to this monitoring.

NODE.general.NtpSntpServer

0.0.0.0

NODE.general.TimeZone

(GMT-08\:00) Los Angeles, Tijuana, Vancouver (Pacific)

NODE.general.UseDST

TRUE

NODE.general.UseNtpSntpServer

FALSE

NODE.protection.1+1.BidirectionalSwitching

FALSE

NODE.protection.1+1.ReversionTime

5.0 (minutes)

NODE.protection.1+1.Revertive

FALSE

NODE.protection.blsr.RingReversionTime

5.0 (minutes)

NODE.protection.blsr.RingRevertive

TRUE

NODE.protection.blsr.SpanReversionTime

5.0 (minutes)

NODE.protection.blsr.SpanRevertive

TRUE

NODE.security.policy.FailedLoginsBeforeLockout

5

NODE.security.policy.IdleUserTimeoutPolicy.Maintenance

60

NODE.security.policy.IdleUserTimeoutPolicy.Provisioning

30

NODE.security.policy.IdleUserTimeoutPolicy.Retrieve

0

NODE.security.policy.IdleUserTimeoutPolicy.Superuser

15

NODE.security.policy.LockoutDuration

00\:30

NODE.security.policy.ManualUnlockBySuperuser

FALSE

NODE.security.policy.PasswordReuseThreshold

1

NODE.security.policy.PasswordReuseTimeou

20

NODE.security.policy.SingleSessionPerUser

FALSE

NODE.timing.bits-1.AISThreshold

SMC

NODE.timing.bits-1.Coding

B8ZS

NODE.timing.bits-1.Framing

ESF

NODE.timing.bits-1.State

IS

NODE.timing.bits-2.AISThreshold

SMC

NODE.timing.bits-2.Coding

B8ZS

NODE.timing.bits-2.Framing

ESF

NODE.timing.bits-2.State

IS

NODE.timing.general.Mode

External

NODE.timing.general.QualityOfRES

RES=DUS

NODE.timing.general.ReversionTime

5.0 (minutes)

NODE.timing.general.Revertive

FALSE

NODE.timing.general.SSMMessageSet

Generation 1



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Feb 25 06:07:07 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.