6.2 Alarm Interface, FAN-ALARM
6.2.3 Electrical Parameters Alarm Input
6.2.4 Electrical Parameters Alarm Output
Physical Interfaces
6.1 Power module, DC Power
Please see section 2.4 Power Module, DC Power, page 2-6.
6.2 Alarm Interface, FAN-ALARM
The ONS 15305 Alarm Interface is described in the following sub-sections.
6.2.1 Description
ONS15305 provides facilities to report a minimum of 4 auxiliary alarm inputs for associated equipment, e.g. power unit failure battery condition, cabinet door etc. and 2 dedicated alarm outputs. The alarm outputs are related to the unit alarm indicator and the traffic alarm indicator. The input alarms are reported to the management system and are activated by a closed or open loop condition between a pair of contacts. See Figure 6-1.
Figure 6-1 Alarm Input and Output Overview
6.2.2 Connectors
The alarm interface connector is a 9 pin DSUB type connector, with the pin-out given in Table 6-1.
6.2.3 Electrical Parameters Alarm Input
Electrical Specification at Alarm Input is found in Table 6-2.
6.2.4 Electrical Parameters Alarm Output
Electrical Specification at Alarm Output is found in Table 6-3.
6.3 Auxiliary Interface
The ONS 15305 Auxiliary Interface is described in the following sub-sections.
6.3.1 Description
ONS 15305 offers a proprietary Auxiliary interface for termination of overhead bytes selected from the different STM-N interfaces. The Auxiliary interface is located on the System controller module, SYSCONT-SD128-RJ45.
Each STM-N interface can be configured to terminate one of the following overhead bytes: E1, F1 or E2. The byte to be terminated is selected from the network management system together with a unique time slot number n, where n equals 1-15 or 17-31. The Auxiliary interface is a framed E1 interface, according to ITU-T G.704, where time slot 1-15 and 17-31 can carry one overhead byte each, according to the configuration described above.
The interface is synchronous which means that the incoming STM-N need to be synchronized with the T0 reference clock in the ONS 15305 and the incoming framed E1 need to be synchronized with the outgoing framed E1. Bit slips will occur if one of the interfaces is free running.
6.3.2 Connector
The connector is a RJ-45 connector, with the pin-out described in Table 6-4.
Table 6-4 Pin Out Auxiliary Interface
Pin Signal1
AUX_DO+
2
AUX_DO-
3
GND
4
AUX_DI+
5
AUX_DI-
6
AUX_SHIELD
7
NC
8
NC
Note Pin 6 is always AC connected to ground
The outer screen is always direct connected to ground.
6.4 VT-100 Terminal Interface
This section describes the ONS 15305 VT-100 Terminal Interface.
6.4.1 Description
ONS15305 offers a VT-100 interface for connection of a Cisco EdgeCraft Terminal/CLI interface. The interface is running at a data rate of 19.200 baud and is located on the System controller module, SYSCONT-SD128-RJ45.
The interface is in accordance with the specifications given in "Connector".
6.4.2 Connector
The RS232 interface for ONS15305 is provided through a RJ-45 connector, with the pin-out described in Table 6-5.
Table 6-5 Pin-out VT-100 Connector
Pin Signal1
GND
2
TxD
3
RxD
4
DB-TxD
5
GND
6
VT_CTS
7
DB_RxD
8
VT_RTS
Note Pin 4 and 7 are only used for debug purposes.
6.5 Synchronization Interface
This section describes the ONS 15305 Synchronization Interface.
6.5.1 Description
The interface is a 120 ohm 2048 kHz synchronization input and output port, with specifications according to ITU-T G.703, and is located on the System controller module, SYSCONT-SD128-RJ45.
6.5.2 Connectors
Both input and output is provided on 8 pin RJ-45 connector, with the pin-out described in Table 6-6.
Table 6-6 Pin Out Synchronization Port
Pin Signal1
SYNC_OUT+
2
SYNC_OUT-
3
GND
4
SYNC_IN+
5
SYNC_IN-
6
SYNC_SCREEN
7
NC
8
NC
Note Pin 6 is always AC connected to ground. The outer screen is always direct connected to ground.
6.6 Management Port
6.6.1 Description
A local Ethernet port (10BaseT), called the Management Port, is available for connecting to a management DCN.
Note The Management Port is configured with a fixed setup - 10Mb / half-duplex.
6.6.2 Connector type
The connector is an RJ-45 Fast Ethernet, with the pin-out described in Table 6-7.
Table 6-7 Management Port - Pin Out
Pin Signal1
TxD+ (In)
2
TxD-- (in)
3
RxD+ (out)
4
NC
5
NC
6
RxD--(out)
7
NC
8
NC
6.6.3 Compliance
Table 6-8 Management Port -Compliance
Standard CommentISO/IEC8877
MAU MDI connector
IEEE 802.3, Clause 14
Twisted pair MAU and baseband medium type 10BASE-T
Management Port compliance is described in Table 6-8.
6.7 Other Interfaces
Other interface descriptions are found in the chapters describing each service module.