cc/td/doc/product/ong/15305/305docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Dual Optical S-4.1 Module

9.1  Functional Description of Module

9.2  Power Consumption

9.3  External Interface

9.4  Connector Type

9.5  Compliance

9.6  Optical Power Budget S4.1-2-LC Two-Fiber

9.7  Optical Power Budget S4.1-2-LC, Single-Fiber Transmission


Dual Optical S-4.1 Module


9.1  Functional Description of Module

The S4.1-2-LC module contains two optical STM-4 interfaces that meets the S-4.1 specification in ITU-T G.957. The physical connector is an LC connector.

The module supports TDM traffic only.

9.2  Power Consumption

The power consumption of the S4.1-2-LC module is 9,5 W.

9.3  External Interface

The interface ia an optical STM-4 short haul interface, according to clause 5 ITU-T G.957. The definitions of optical parameters and reference points S and R refer to ITU-T G.957. Reference point S refers to the transmit direction and R refers to the receive direction of the fiber. The following descriptions refer to both single mode fiber and multimode fiber. Bidirectional transmission on a single fiber is possible using an external 3dB directional coupler with the S4.1-2-LC module.

9.4  Connector Type

The physical connector is a LC connector.

Figure 9-1 Dual Optical S-4.1 Module, S4.1-2-LC.

9.5  Compliance

Table 9-1 Optical Interface Compliance

Standard
Comment

ITU-T G.652

Single Mode fiber specification 10/125

ITU-T G.651

Multimode fiber specification 50/125 µm

IEC 793-2

Multimode fiber specification 62.5/125 µm

ITU-T G.707

Optical line signal

ITU-T G.783

RX pull-in and hold range

ITU-T G.813

Optical output jitter

ITU-T G.825

Optical input jitter

ITU-T G.957

Optical spectrum,

Optical output power,

Optical eye diagram,

Optical extinction ratio.


9.6  Optical Power Budget S4.1-2-LC Two-Fiber

Table 9-2 Optical Power Budget STM-4 S4.1 SH and LH

Parameter
Short-Haul
   

Types of fiber:

ITU-T Rec. G.652 SM

10/125

µm

ITU-T Rec. G.651 MM

50/125

IEC 739-2 MM

62.5/125

Modulation rate on optical line

622 080

kbps

Wavelength range

1274 - 1356

nm

Transmitter at reference point S

Source type

MLM

 

Spectral characteristics (max. RMS width)

2.5

nm

Mean launched power (max.)

-8

dBm

Mean launched power (min.)

-15

dBm

Min. extinction ratio

8.2

dB

Optical path between S and R

Attenuation range

0 - 12

dB

Max. tolerable dispersion

200

ps/nm (SM fiber)

Min. optical return loss

NA

 

Max. discrete reflectance between S and R

NA

 
Receiver at reference point R

Min. sensitivity (BER < 1 in 1010)

-28

dBm

Min. overload

-8

dBm

Max. optical path penalty

1

dB

Max. reflectance at R

NA

 

9.7  Optical Power Budget S4.1-2-LC, Single-Fiber Transmission

Bidirectional transmission on a single fiber is possible using an external 3dB directional coupler with the S4.1-2-LC module.

STM-4 S4.1 single fiber has the same specification on the S and R interfaces as the two fiber SH version.

Cisco recommends using mode-conducting cord for offset launch when the quality of multimode fiber is unknown.

:

Table 9-3 Directional Coupler Properties

Directional Coupler Properties
Short-Haul
 

Directivity

>40

dB

Maximum insertion loss in coupler

4

dB


:

Table 9-4 Optical Power Budget Single Fiber Parameters

Parameter
Value
 

Type of fiber: ITU-T Rec. G.652

10/125

µm

Modulation rate on optical line

622 080

kbps

Wavelength range

1274 - 1356

nm

Transmitter at reference point C

Source type

MLM

 

Spectral characteristics (max. RMS width)

2.5

nm

Mean launched power (max.)

-11

dBm

Mean launched power (min.)

-19

dBm

Min. extinction ratio

8.2

dB

Optical path between C and remote C

Attenuation range

0 - 4

dB

Max. tolerable dispersion

260

ps/nm

Min. optical return loss of cable plant at C

30

dB

Max. discrete reflectance between C points

-36

dB

Receiver at reference point C

Min. sensitivity (BER < 1 in 1010)

-24

dBm

Min. overload

-5

dBm

Max. optical path penalty

1

dB



Note The STM-4 S4.1 power monitoring of mean Rx power is measured on the R interface.