Single Optical S-16.1 Module

8.1  Functional Description of Module

8.2 Power Consumption

8.3 External Interface

8.4 Connector Type

8.5 Optical Budget

8.6 Traffic Alarms


Single Optical S-16.1 Module


8.1  Functional Description of Module

The S16.1-1-LC module contains one optical STM-16 interfaces that meets the S-16.1 specification in ITU-T G.957. The physical connector is a LC connector.

The module supports TDM traffic only.

8.2 Power Consumption

The power consumption of the S16.1-1-LC module is 13 W.

8.3 External Interface

The interface is an optical STM-16 short haul interface, according to clause 5 ITU-T G.957. The definitions of optical parameters and reference points S and R refer to ITU-T G.957. Reference point S refers to the transmit direction and R refers to the receive direction of the fiber.

8.4 Connector Type

The physical connector is a LC connector.

Figure 8-1 Single Optical S-16.1 Module, S16.1-1-LC

8.5 Optical Budget

Table 8-1 Optical Budget S-16.1

Parameter
Value

Modulation rate on optical line

2488 380 kbps

Wavelength range

1261 - 1360 nm

Transmitter at reference point S
 

Source type

SLM

Maximum -20dB width

1nm

minimum side mode suppression ratio

30dB

Mean launched power (max.)

0dBm

Mean launched power (min.)

-5 dBm

Min. extinction ratio

8.2 dB

Optical path between S and R
 

Attenuation range

0 - 12 dB

Max. tolerable dispersion

NA

Min. optical return loss at S inc. any connectors

24dB

Max. discrete reflectance between S and R

-27dB

Receiver at reference point R
 

Min. sensitivity (BER < 1 in 1010)

-18 dBm

Min. overload

0 dBm

Max. optical path penalty

1 db

Max. reflectance at R

-27dB


8.6 Traffic Alarms

Rx direction

Loss of signal (LOS): Traffic Alarm. Optical power of input signal is below receiver sensitivity level.

Loss of lock (LOL): Indicates clock recovery of de-serializer is out of lock. Signal must be present for indication to be valid. Indication to be reported as unit failure alarm.

Transmit failure: Laser degradation