Troubleshooting

5.1 Introduction

5.2 Problem Solving

5.3 Identify Start-up Problems

5.4 Restore Factory Pre-configuration

5.4.1 Additional Terminal Settings

5.4.2 Prepare the Script File

5.4.3 Erase a File (CDB file)

5.4.4 Send Scripts Procedure


Troubleshooting


This chapter enable the user to solve problems with the ONS 15302.

5.1 Introduction

The ONS 15302 is tested extensively and verify before leaving the factory. However, if your system appears to have problems during start up, use the information to help isolate the cause.

When the initial system boot is complete, verify the following:

Power is being supplied to the system.

System software boots successfully.

If the start-up sequence fails before these conditions are met, use the procedures in this chapter to isolate and, if possible, resolve the problem.

If you are unable to easily solve the problem, contact TAC for assistance and further instructions. Have the following information ready to help TAC assist you as quickly as possible:

Date you received the equipment

Chassis serial number

Type of software and release number

Brief description of the problem you are having

Brief explanation of the steps you have already taken to isolate and resolve the problem

Maintenance agreement or warranty information

5.2 Problem Solving

The key to problem solving the system is to try to isolate the problem to a specific subsystem. The first step in solving start-up problems is to compare what the system is doing to what it should be doing. Since a start-up problem can usually be attributed to a single component, it is more efficient to first isolate the problem to a subsystem rather than troubleshoot each separate component in the system.

The ONS 15302 consists of the following subsystems.

Main Card

WAN-module

Optical system (protected or unprotected)

5.3 Identify Start-up Problems

LEDs indicate all system states in the start-up sequence. By checking the state of the LEDs, you can determine when and where the system failed in the start-up sequence.

When you plug in the power supply to start the system, the following should occur:

The Power LED turns green when you plug in the connector.

The Operation, Customer and Test LEDs operate as follows during equipment start-up.

All LEDs are lit simultaneously for a few seconds with an interval of ~1 minute during start-up. The start-up procedure takes approximately 3 minutes.

The LED indicators are used to visualize the ONS 15302 status:

Table 5-1 LED Functionality on the WAN Module Side 

Identity
Color
State
On
State
Flashing
State
Off

PWR (Power)

Green

Presence of power

NA

Power failure

OPER
(Operation)

Red

Alarm detected on aggregate interface

NA

No alarm detected on aggregate interface

CUST (Customer)

Red

Alarm detected on tributary or LAN interface

NA

No alarm detected on tributary or LAN interface

TEST
(Test)

Yellow

 

One or more test are activated

 

LAN 1

Green

Link is present

Traffic is present

Link down

LAN 2

Green

Link is present

Traffic is present

Link down

LAN 3

Green

Link is present

Traffic is present

Link down

LAN 4

Green

Link is present

Traffic is present

Link down


Table 5-2 LED Functionality on the Connector Array Side 

Identity
Position
Color
State
On
State
Flashing
State
Off

PWR (Power)

 

Green

Presence of power

NA

Power failure

OPER
(Operation)

 

Red

Alarm detected on aggregate interface

NA

No alarm detected on aggregate interface

CUST (Customer)

 

Red

Alarm detected on tributary or LAN interface

NA

No alarm detected on tributary or LAN interface

TEST
(Test)

 

Yellow

 

One or more test are activated

 

LANn (n-1,2,3,4)

Left

Green

100 MBits/s (Mbps)

NA

NA

LANn (n-1,2,3,4)

Left

Yellow

10 MBits/s (Mbps)

NA

NA

LANn (n-1,2,3,4)

Right

Green

Link OK

Ethernet traffic in operation

Link down


5.4 Restore Factory Pre-configuration

This section describes how to restore factory pre-configuration to the ONS 15302.

The simplest way to automatically configure an ONS 15302 is to take advantage of VT100 emulating software. From a VT100 terminal it is possible to send a text file (script) instead of manually writing paths and command(s) to change or add configuration on the device.

This procedure for restoring the factory pre-configuration assumes that the user has installed the HyperTerminal program on a common PC running Microsoft Windows 2000, but most of the content will work with any terminal emulation software. In addition it is necessary to use a console cable (CLI cable) according to the specification to connect a COM port on the PC with the VT100 interface on the ONS 15302.

5.4.1 Additional Terminal Settings

In addition to the standard parameters for communicating with the ONS 15302 ( Table 5-3) it is also necessary to adjust the line delay (the time to wait between sending commands to the device), to allow for responses from the device. If the command issued results in the display of a long table, this will require more time than simple one-line responses The optimal time might vary between PC, so you might have to try a couple of different settings. A good start value is 500 ms. In some cases increasing character delay to a few milliseconds might help too. Exactly where to adjust this in HyperTerminal see Table 5-3.

Table 5-3 EIA/TIA 232 Interface

Parameter
Condition

Baud rate

19.2 kbaud

Data bits

8

Parity

None

Stop bits

1


Figure 5-1, Figure 5-2 and Figure 5-3 describes how to configure the Line delay.

Figure 5-1 Select Properties

Figure 5-2 Select ASCII Setup

Figure 5-3 Configure Line Delay

5.4.2 Prepare the Script File

The script file can be prepared by using a text editor program, for example, Notepad for Windows computers. The content in a script file is only limited to valid commands and paths for ONSCLI. Examples below show the script files for the pre-configuration of the unprotected and protected versions that is to be used when installing a device from the factory.

Unprotected Version:

dev\vlan\vlan-t\add name=vlan1

dev\vlan\vlan-p\add if=100000 eth=1,2,3,4,5 tag=dis

port\agg\gen adm=en

port\eth\wan\add wan=5 nu=1

sec\commun\add man=0.0.0.0 comm=public acc=super tra=dis

Protected Version:

dev\vlan\vlan-t\add name=vlan1

dev\vlan\vlan-p\add if=100000 eth=1,2,3,4,5 tag=dis

port\agg\gen agg=1 adm=en

port\eth\wan\add wan=5 nu=1

sec\commun\add man=0.0.0.0 comm=public acc=super tra=dis

5.4.3 Erase a File (CDB file)

Since the purpose of this section is to restore factory pre-configurations the unit has most likely been configured with testing parameters. To make sure that CDB file is empty we recommend that it is erased before sending the text file down to the device. To perform this on the ONS 15302 follow the steps below.


Step 1 Login to command line interface by typing ONSCLI and ONSCLI again when prompted for password

Step 2 Select the following command:

>ONSCLI\Device\erase

Typing yes when prompted!

Step 3 To complete the CDB erase you will have to reboot the system. Write the following command:

>ONSCLI\Device\reset

Typing yes when prompted!


When the ONS 15302 has restarted you are ready to perform the procedure in Send Scripts Procedure.

5.4.4 Send Scripts Procedure

The procedure for sending scripts to the device is rather simple if the above preparations are completed. Please login to the ONSCLI, and follow these steps to accomplish the restoration of factory pre-configuration


Step 1 Select in the pull down menu transfer and the command send text file, Figure 5-4.

Figure 5-4 Select Send Text File

Step 2 Select in the send text file window the file that you want to download, Figure 5-5.

Figure 5-5 Select the File

If all necessary preparations are performed as described in this section the ONS 15302 should now be successfully configured according to factory pre-configuration.