Applications

3.1  Application Overview

3.2  Optical Performance of 1.25 GBIC Interfaces

3.2.1  Linear Layout

3.2.2  Parallel Layout

3.3  Broadcast Node FlexLayer Configuration

3.4  In-Line Drop Node FlexLayer Configuration

3.5  Drop-and-Broadcast Node FlexLayer Configuration

3.6  Line-Amplifier Node FlexLayer Configuration


Applications


3.1  Application Overview

The purpose of the FlexLayer Asymmetric DWDM component system is unidirectional Video on Demand (VoD) applications. These applications require only one channel, the OSC (if used), to be bidirectional. The other channels are unidirectional. The ONS 15216 R2.1 channel plan (32 channels, 100 GHz spacing) is used in this release. Table 3-1 shows how the FlexLayer A/D modules are grouped in relation to the supported channels.

Table 3-1 ONS15216 r2.1 100 GHz Channel Plan 

ITU
Channel ID
Frequency (THz)
Wavelength (nm)
2 Ch A/D Flex Module
8 Ch A/D Flex Module

59

30.3

195.9

1530.33

   

58

31.1

195.8

1531.12

57

31.9

195.7

1531.90

 

56

32.6

195.6

1532.68

54

34.2

195.4

1534.25

 

53

35.0

195.3

1535.04

52

35.8

195.2

1535.82

 

51

36.6

195.1

1536.61

49

38.1

194.9

1538.19

   

48

38.9

194.8

1538.98

47

39.7

194.7

1539.77

 

46

40.5

194.6

1540.56

44

42.1

194.4

1542.14

 

43

42.9

194.3

1542.94

42

43.7

194.2

1543.73

 

41

44.5

194.1

1544.53

39

46.1

193.9

1546.12

   

38

46.9

193.8

1546.92

37

47.7

193.7

1547.72

 

36

48.5

193.6

1548.51

34

50.1

193.4

1550.12

 

33

50.9

193.3

1550.92

32

51.7

193.2

1551.72

 

31

52.5

193.1

1552.52

29

54.1

192.9

1554.13

   

28

54.9

192.8

1554.94

27

55.7

192.7

1555.75

 

26

56.5

192.6

1556.55

24

58.1

192.4

1558.17

 

23

58.9

192.3

1558.98

22

59.7

192.2

1559.79

 

21

60.6

192.1

1560.61


The ONS 15216 FlexLayer system is designed to support the DWDM transmission of 1.25 gigabit interface converter (GBIC) interfaces. The reference performance of these interfaces is reported in Table 3-2. The ONS 15216 FlexLayer system deploys the ONS 15216 EDFA2 for optical amplification of the signal.


Note The ONS 15216 FlexLayer system can also support 2.5G and 10G transmissions; contact your sales representative for information.


Table 3-2 Reference Optical Performance of 1.25 GBIC Interfaces

Max Bit Rate
Regen
FEC
Threshold
Max BER
Min Required OSNR1
Received Power Range
Transmitted Power Range

1.25 Gb/s

N/A

No

Average

10-12

20 dB

-28 to -7 dBm

0 to +4 dBm

1 Measured on 0.1 nm Resolution Bandwidth.


Figure 3-1 illustrates a typical ONS 15216 FlexLayer architecture.

Figure 3-1 A Typical ONS 15216 FlexLayer Architecture

These unidirectional channels are transported from one side and available at every remote site. The channel requirements at that site can be de-multiplexed as necessary. In the ONS 15216 FlexLayer architectures, nodes are designed for specific roles. These roles include:

Head-End Node

Broadcast Node

In-Line Drop Node

Drop-and-Broadcast Node

Line-Amplifier Node

Figure 3-2 shows the required Cisco VoD GigE transport solutions. In Figure 3-2, the top solution uses the Cisco Catalyst 45XX w/ITU GBICs. The bottom solution uses the Cisco ONS 15454 w/GE transponders.

Figure 3-2 Cisco GigE VoD Transport Solutions

3.2  Optical Performance of 1.25 GBIC Interfaces

The head-end node is a terminal node that transmits all the channels passing through it. This node performs a complete multiplexing of the channels. Typical equipment layouts include the linear and parallel configurations.

3.2.1  Linear Layout

The basic elements of the node are the n-channel add/drop modules used in the add arrangement. They collect traffic from the client equipment and aggregate it in a DWDM composite signal on a single fiber. Modules are connected in series (that is, the output of a card to the input of another one) to build a linear configuration. A linear configuration allows the highest degree of flexibility for a future non-service -affecting upgrade of the terminal site channel capacity.

When new channels are added to the multiplexing capacity, the output port of the new module is connected to the input port of the first module of the chain. An optical amplifier can be inserted at the output of the last card to recover for the node losses. The OSC filter can be inserted at the node output to allow OSC capabilities in conjunction with the client equipment.

Figure 3-3 shows a FlexLayer linear head-end configuration.

Figure 3-3 A FlexLayer Linear Head-End Configuration

3.2.2  Parallel Layout

The parallel layout uses a x:1 combiner module to collect output signals from add modules. The combiner limits the maximum number of add modules that can be deployed in the node, but achieves a better channel power equalization when compared to the linear layout. The VOA module is added to fine tune the channel sub-band equalization. An optical amplifier can be introduced at the output of the combiner to recover for the network element insertion loss. The OSC filter can be inserted at the node output to allow OSC capabilities in conjunction with the client equipment. Figure 3-4 shows a FlexLayer parallel head-end configuration.

Figure 3-4 FlexLayer Parallel Head-End Configuration

3.3  Broadcast Node FlexLayer Configuration

The broadcast node has one input optical port and two or more optical output ports. The node replicates the input signal spectrum at the output ports, thus allowing a wider distribution of the data traffic. Optical amplifiers can be connected to the input or to one or more of the output ports to recover for node insertion losses or to allow further propagation. It must be noted that the optical amplifiers are both optional, and their presence depends on the network. The OSC filters can be inserted at the node input and at the node output ports to allow OSC capabilities in conjunction with the client equipment. Figure 3-5 shows how a FlexLayer broadcast node could be set up.

Figure 3-5 FlexLayer Broadcast Node Configuration

3.4  In-Line Drop Node FlexLayer Configuration

The drop node performs the extraction of some channels from the composite signal leaving remnant channels available on the output port. The client equipment is connected to the drop ports of the drop modules. Each module output port is connected to the input port of another module in a chain arrangement. The channel power and the receiver define the order of the modules. The input port of the first module is the input port of the node. An optical amplifier can be inserted here to recover for insertion losses. The output port of the last drop module is the output port of the network element. An optical amplifier can be inserted here to recover for insertion losses.


Note The optical amplifiers are both optional, and their presence depends on the network.


If at least one amplifier is present, the OADM node is called an "active drop node," otherwise the node is called a "passive node."

If an optical amplifier is inserted at the input port of the node, the VOA module must be used between some of the drop modules and the client equipment to avoid damage of the client equipment. The OSC filters can be further inserted at the node input and at the node output to allow OSC capabilities in conjunction with the client equipment. If the output port is unconnected the node acts as a terminal node. Figure 3-6 shows how a typical FlexLayer in-line drop node configuration can be organized.

Figure 3-6 FlexLayer In-Line Drop Node Configuration

3.5  Drop-and-Broadcast Node FlexLayer Configuration

The drop-and-broadcast node extracts some channels from the composite DWDM signal and replicates (regenerates) all the channels on the output ports. The client equipment is connected to the drop ports of the drop modules. Each FlexLayer module output port is connected to the input port of another FlexLayer module in a chain arrangement. The input port of the first FlexLayer module is the input port of the node. An optical amplifier can be inserted here to recover for insertion losses. The output port of the last FlexLayer module is the output port of the network element. An optical amplifier can be inserted here to recover for insertion losses.


Note The optical amplifiers are all optional, and their presence depends on the network.


If at least one amplifier is present the OADM node is called an "active drop node," otherwise the node is called a "passive node".

If an optical amplifier is inserted at the input port of the node, the VOA module must be used between some of the drop modules and the client equipment to avoid damage to the client equipment. The OSC filters can be inserted at the node input and at the node output ports to allow OSC capabilities in conjunction with the client equipment. Figure 3-7 shows how a typical FlexLayer drop-and-broadcast node configuration can be organized.

Figure 3-7 FlexLayer Drop-and-Broadcast Node Configuration

3.6  Line-Amplifier Node FlexLayer Configuration

The line amplifier node performs signal power recovery to achieve a longer transmission distance. It is composed of optical amplifiers only. The OSC filters can be inserted at the node input and at the node output ports to allow OSC capabilities in conjunction with the client equipment. Figure 3-8 shows a FlexLayer line-amplifier node configuration.

Figure 3-8 FlexLayer Line-Amplifier Node Configuration