cc/td/doc/product/mels/cmet1500
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Connecting Jumpers

Connecting Jumpers

This chapter provides information on jumper connections for wavelength channels with MUX/DMX, MUX/DMX with band splitter modules (BSMs), and BSM with remote switch modules (RSMs). It also provides an overview of the various jumper types used in these connections.

This chapter includes the following sections:

Connecting 16-Channel WCM System Jumpers

The jumper connections in this section are for a 16-channel system installed in a single rack with the following:

Table 6-1 to Table 6-5 show the appropriate jumper lengths and the jumper connections in this section.


Table 6-1: Connecting Wavelength Channels CH1-CH8 with MUX/DMX 1-8
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        1

WCM

CH 1

R/R

        1

DMX 1-8

        1

390

(1.27)

R/T

MUX 1-8

        1

390

(1.27)

WCM

CH 2

R/R

DMX 1-8

        2

390

(1.27)

R/T

MUX 1-8

        2

390

(1.27)

WCM

CH 3

R/R

DMX 1-8

        3

360

(1.18)

R/T

MUX 1-8

        3

360

(1.18)

WCM

CH 4

R/R

DMX 1-8

        4

360

(1.18)

R/T

MUX 1-8

        4

360

(1.18)

WCM

CH 5

R/R

DMX 1-8

        5

360

(1.18)

R/T

MUX 1-8

        5

360

(1.18)

WCM

CH 6

R/R

DMX 1-8

        6

360

(1.18)

R/T

MUX 1-8

        6

360

(1.18)

WCM

CH 7

R/R

DMX 1-8

        7

310

(1.01)

R/T

MUX 1-8

        7

310

(1.01)

WCM

CH 8

R/R

DMX 1-8

        8

310

(1.01)

R/T

MUX 1-8

        8

310

(1.01)


Table 6-2: Connecting Wavelength Channels CH9-CH16 with MUX/DMX 9-16
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        2

WCM

CH 9

R/R

        2

DMX 9-16

        9

390

(1.27)

R/T

MUX 9-16

        9

390

(1.27)

WCM

CH 10

R/R

DMX 9-16

       10

390

(1.27)

R/T

MUX 9-16

       10

390

(1.27)

WCM

CH 11

R/R

DMX 9-16

       11

360

(1.18)

R/T

MUX 9-16

       11

360

(1.18)

WCM

CH 12

R/R

DMX 9-16

       12

360

(1.18)

R/T

MUX 9-16

       12

360

(1.18)

WCM

CH 13

R/R

DMX 9-16

       13

360

(1.18)

R/T

MUX 9-16

       13

360

(1.18)

WCM

CH 14

R/R

DMX 9-16

       14

360

(1.18)

R/T

MUX 9-16

       14

360

(1.18)

WCM

CH 15

R/R

DMX 9-16

       15

310

(1.01)

R/T

MUX 9-16

       15

310

(1.01)

WCM

CH 16

R/R

DMX 9-16

       16

310

(1.01)

R/T

MUX 9-16

       16

310

(1.01)


Table 6-3: Connecting MUX/DMX 1-16 (16) with BSM
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        1

DMX 1-8

D1

      2

BSM

D1

750

(2.46)

MUX 1-8

M1

M1

750

(2.46)

        2

DMX 9-16

D2

D2

310

(1.01)

MUX 9-16

M2

M2

310

(1.01)


Table 6-4: Connecting a BSM with a RSM
From To Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

2

BSM

D

1

RSM

D

310

(1.01)

BSM

M

M

310

(1.01)


Table 6-5: Jumper Overview
Quantity Jumper Type Jumper Length

mm

(ft)

12

MU/PC-MU/PC-SM

310

(1.01)

16

MU/PC-MU/PC-SM

360

(1.18)

8

MU/PC-MU/PC-SM

390

(1.27)

2

MU/PC-MU/PC-SM

750

(2.46)

Connecting 32-Channel WCM System Jumpers

The jumper connections in this section are for a 32-channel system installed in a single rack with the following:

Table 6-6 to Table 6-12 show the appropriate jumper lengths and the jumper connections in this section.


Table 6-6: Connecting Wavelength Channels CH1-CH8 with MUX/DMX 1-8
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        1

WCM

CH 1

R/R

        1

DMX 1-8

        1

390

(1.27)

R/T

MUX 1-8

        1

390

(1.27)

WCM

CH 2

R/R

DMX 1-8

        2

390

(1.27)

R/T

MUX 1-8

        2

390

(1.27)

WCM

CH 3

R/R

DMX 1-8

        3

360

(1.18)

R/T

MUX 1-8

        3

360

(1.18)

WCM

CH 4

R/R

DMX 1-8

        4

360

(1.18)

R/T

MUX 1-8

        4

360

(1.18)

WCM

CH 5

R/R

DMX 1-8

        5

360

(1.18)

R/T

MUX 1-8

        5

360

(1.18)

WCM

CH 6

R/R

DMX 1-8

        6

360

(1.18)

R/T

MUX 1-8

        6

360

(1.18)

WCM

CH 7

R/R

DMX 1-8

        7

310

(1.01)

R/T

MUX 1-8

        7

310

(1.01)

WCM

CH 8

R/R

DMX 1-8

        8

310

(1.01)

R/T

MUX 1-8

        8

310

(1.01)


Table 6-7: Connecting Wavelength Channels CH9-CH16 with MUX/DMX 9-16
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        2

WCM

CH 9

R/R

        2

DMX 9-16

        9

390

(1.27)

R/T

MUX 9-16

        9

390

(1.27)

WCM

CH 10

R/R

DMX 9-16

       10

390

(1.27)

R/T

MUX 9-16

       10

390

(1.27)

WCM

CH 11

R/R

DMX 9-16

       11

360

(1.18)

R/T

MUX 9-16

       11

360

(1.18)

WCM

CH 12

R/R

DMX 9-16

       12

360

(1.18)

R/T

MUX 9-16

       12

360

(1.18)

WCM

CH 13

R/R

DMX 9-16

       13

360

(1.18)

R/T

MUX 9-16

       13

360

(1.18)

WCM

CH 14

R/R

DMX 9-16

       14

360

(1.18)

R/T

MUX 9-16

       14

360

(1.18)

WCM

CH 15

R/R

DMX 9-16

       15

310

(1.01)

R/T

MUX 9-16

       15

310

(1.01)

WCM

CH 16

R/R

DMX 9-16

       16

310

(1.01)

R/T

MUX 9-16

       16

310

(1.01)


Table 6-8: Connecting Wavelength Channels CH17-CH24 with MUX/DMX 17-24
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        3

WCM

CH 17

R/R

        3

DMX 17-24

       17

390

(1.27)

R/T

MUX 17-24

       17

390

(1.27)

WCM

CH 18

R/R

DMX 17-24

       18

390

(1.27)

R/T

MUX 17-24

       18

390

(1.27)

WCM

CH 19

R/R

DMX 17-24

       19

360

(1.18)

R/T

MUX 17-24

       19

360

(1.18)

WCM

CH 20

R/R

DMX 17-24

       20

360

(1.18)

R/T

MUX 17-24

       20

360

(1.18)

WCM

CH 21

R/R

DMX 17-24

       21

360

(1.18)

R/T

MUX 17-24

       21

360

(1.18)

WCM

CH 22

R/R

DMX 17-24

       22

360

(1.18)

R/T

MUX 17-24

       22

360

(1.18)

WCM

CH 23

R/R

DMX 17-24

       23

310

(1.01)

R/T

MUX 17-24

       23

310

(1.01)

WCM

CH 24

R/R

DMX 17-24

       24

310

(1.01)

R/T

MUX 17-24

       24

310

(1.01)


Table 6-9: Connecting Wavelength Channels CH25-CH32 with MUX/DMX 25-32
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        4

WCM

CH 25

R/R

        4

DMX 17-24

       25

390

(1.27)

R/T

MUX 17-24

       25

390

(1.27)

WCM

CH 26

R/R

DMX 17-24

       26

390

(1.27)

R/T

MUX 17-24

       26

390

(1.27)

WCM

CH 27

R/R

DMX 17-24

       27

360

(1.18)

R/T

MUX 17-24

       27

360

(1.18)

WCM

CH 28

R/R

DMX 17-24

       28

360

(1.18)

R/T

MUX 17-24

       28

360

(1.18)

WCM

CH 29

R/R

DMX 17-24

       29

360

(1.18)

R/T

MUX 17-24

       29

360

(1.18)

WCM

CH 30

R/R

DMX 17-24

       30

360

(1.18)

R/T

MUX 17-24

       30

360

(1.18)

WCM

CH 31

R/R

DMX 17-24

       31

310

(1.01)

R/T

MUX 17-24

       31

310

(1.01)

WCM

CH 32

R/R

DMX 17-24

       32

310

(1.01)

R/T

MUX 17-24

       32

310

(1.01)


Table 6-10: Connecting MUX/DMX 1-32 (32) with a BSM
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        1

DMX 1-8

D1

      2

BSM

D1

750

(2.46)

MUX 1-8

M1

M1

750

(2.46)

        2

DMX 9-16

D2

D2

310

(1.01)

MUX 9-16

M2

M2

310

(1.01)

        3

DMX 17-24

D3

D3

750

(2.46)

MUX 17-24

M3

M3

750

(2.46)

        4

DMX 25-32

D4

D4

1300

(4.26)

MUX 25-32

M4

M4

1300

(4.26)


Table 6-11: Connecting a BSM with an RSM
                             From                                    To     Jumper Length

Chassis

Module

Connector

Chassis

Module

Connector

mm

(ft)

        2

BSM

D

        1

RSM

D

310

(1.01)

BSM

M

M

310

(1.01)


Table 6-12: Jumper Overview
Quality Jumper Type Jumper Length

mm

(ft)

20

MU/PC-MU/PC-SM

310

(1.01)

32

MU/PC-MU/PC-SM

360

(1.18)

16

MU/PC-MU/PC-SM

390

(1.27)

4

MU/PC-MU/PC-SM

750

(2.46)

2

MU/PC-MU/PC-SM

1300

(4.26)

Connecting 32-Channel TDM4E System Jumpers

The jumper connections in this section are for a 128 ESCON channel system installed in two racks with the following:

Table 6-13 to Table 6-23 shows the appropriate jumper lengths and the jumper connections in this section.


Table 6-13: Connecting Wavelength Channels CH1-CH4 with MUX/DMX 1-8
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     1

TDM4E

CH 1

R/R

     I

     1

DMX 1-8

        1

380

(1.24)

R/T

MUX 1-8

        1

300

(0.98)

TDM4E

CH 2

R/R

DMX 1-8

        2

300

(0.98)

R/T

MUX 1-8

        2

280

(0.92)

TDM4E

CH 3

R/R

DMX 1-8

        3

280

(0.92)

R/T

MUX 1-8

        3

260

(0.85)

TDM4E

CH 4

R/R

DMX 1-8

        4

260

(0.85)

R/T

MUX 1-8

        4

260

(0.85)


Table 6-14: Connecting Wavelength Channels CH5-CH8 with MUX/DMX 1-8
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     2

TDM4E

CH 5

R/R

     I

     1

DMX 1-8

        5

800

(2.62)

R/T

MUX 1-8

        5

800

(2.62)

TDM4E

CH 6

R/R

DMX 1-8

        6

820

(2.62)

R/T

MUX 1-8

        6

820

(2.62)

TDM4E

CH 7

R/R

DMX 1-8

        7

840

(2.75)

R/T

MUX 1-8

        7

840

(2.75)

TDM4E

CH 8

R/R

DMX 1-8

        8

860

(2.82)

R/T

MUX 1-8

        8

860

(2.82)


Table 6-15: Connecting Wavelength Channels CH9-CH12 with MUX/DMX 9-16
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     3

TDM4E

CH 9

R/R

     I

     3

DMX 9-16

        9

380

(1.24)

R/T

MUX 9-16

        9

300

(0.98)

TDM4E

CH 10

R/R

DMX 9-16

       10

300

(0.98)

R/T

MUX 9-16

       10

280

(0.92)

TDM4E

CH 11

R/R

DMX 9-16

       11

280

(0.92)

R/T

MUX 9-16

       11

260

(0.85)

TDM4E

CH 12

R/R

DMX 9-16

       12

260

(0.85)

R/T

MUX 9-16

       12

260

(0.85)


Table 6-16: Connecting Wavelength Channels CH13-CH16 with MUX/DMX 9-16
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     4

TDM4E

CH 13

R/R

     I

     3

DMX 9-16

13

800

(2.62)

R/T

MUX 9-16

13

800

(2.62)

TDM4E

CH 14

R/R

DMX 9-16

14

820

(2.69)

R/T

MUX 9-16

14

820

(2.69)

TDM4E

CH 15

R/R

DMX 9-16

15

840

(2.75)

R/T

MUX 9-16

15

840

(2.75)

TDM4E

CH 16

R/R

DMX 9-16

16

860

(2.82)

R/T

MUX 9-16

16

860

(2.82)


Table 6-17: Connecting Wavelength Channels CH17-CH20 with MUX/DMX 17-24
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     II

     5

TDM4E

CH 17

R/R

     II

     5

DMX 17-24

       17

380

(1.24)

R/T

MUX 17-24

       17

300

(0.98)

TDM4E

CH 18

R/R

DMX 17-24

       18

300

(0.98)

R/T

MUX 17-24

       18

280

(0.92)

TDM4E

CH 19

R/R

DMX 17-24

       19

280

(0.92)

R/T

MUX 17-24

       19

260

(0.85)

TDM4E

CH 20

R/R

DMX 17-24

       20

260

(0.85)

R/T

MUX 17-24

       20

260

(0.85)


Table 6-18: Connecting Wavelength Channels CH21-CH24 with MUX/DMX 17-24
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     II

     6

TDM4E

CH 21

R/R

     II

     5

DMX 17-24

       21

800

(2.62)

R/T

MUX 17-24

       21

800

(2.62)

TDM4E

CH 22

R/R

DMX 17-24

       22

820

(2.69)

R/T

MUX 17-24

       22

820

(2.69)

TDM4E

CH 23

R/R

DMX 17-24

       23

840

(2.75)

R/T

MUX 17-24

       23

840

(2.75)

TDM4E

CH 24

R/R

DMX 17-24

       24

860

(2.82)

R/T

MUX 17-24

       24

860

(2.82)


Table 6-19: Connecting Wavelength Channels CH25-CH28 with MUX/DMX 25-32
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     II

     7

TDM4E

CH 25

R/R

     II

     7

DMX 25-32

       25

380

(1.24)

R/T

MUX 25-32

       25

300

(0.98)

TDM4E

CH 26

R/R

DMX 25-32

       26

300

(0.98)

R/T

MUX 25-32

       26

280

(0.92)

TDM4E

CH 27

R/R

DMX 25-32

       27

280

(0.92)

R/T

MUX 25-32

       27

260

(0.85)

TDM4E

CH 28

R/R

DMX 25-32

       28

260

(0.85)

R/T

MUX 25-32

       28

260

(0.85)


Table 6-20: Connecting Wavelength Channels CH29-CH32 with MUX/DMX 25-32
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     II

     8

TDM4E

CH 29

R/R

     II

     7

DMX 25-32

       29

800

(2.62)

R/T

MUX 25-32

       29

800

(2.62)

TDM4E

CH 30

R/R

DMX 25-32

       30

820

(2.69)

R/T

MUX 25-32

       30

820

(2.69)

TDM4E

CH 31

R/R

DMX 25-32

       31

840

(2.75)

R/T

MUX 25-32

       31

840

(2.75)

TDM4E

CH 32

R/R

DMX 25-32

       32

860

(2.82)

R/T

MUX 25-32

       32

860

(2.82)


Table 6-21: Connecting MUX/DMX 1-32 (32) with a BSM
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     1

DMX 1-8

D1

     I

     2

BSM

D1

900

(2.95)

MUX 1-8

M1

M1

900

(2.95)

     3

DMX 9-16

D2

D2

1000

(3.28)

MUX 9-16

M2

M2

1000

(3.28)

     II

     5

DMX 17-24

D3

D3

4000

(13.12)

MUX 17-24

M3

M3

4000

(13.12)

     7

DMX 25-32

D4

D4

4000

(13.12)

MUX 25-32

M4

M4

4000

(13.12)


Table 6-22: Connecting a BSM with a RSM
                           From                                          To Jumper Length

Rack

Chassis

Module

Connector

Rack

Chassis

Module

Connector

mm

(ft)

     I

     2

BSM

D

     I

     1

RSM

D

1000

(3.28)

BSM

M

M

1000

(3.28)


Table 6-23: Jumper Overview
Quality Jumper Type Jumper Length

mm

(ft)

12

MU/PC-MU/PC-SM

260

(0.85)

8

MU/PC-MU/PC-SM

280

(0.92)

8

MU/PC-MU/PC-SM

300

(0.98)

4

MU/PC-MU/PC-SM

380

(1.24)

8

MU/PC-MU/PC-SM

800

(2.62)

8

MU/PC-MU/PC-SM

820

(2.69)

8

MU/PC-MU/PC-SM

840

(2.75)

8

MU/PC-MU/PC-SM

860

(2.82))

2

MU/PC-MU/PC-SM

900

(2.95)

4

MU/PC-MU/PC-SM

1000

(3.28)

4

MU/PC-MU/PC-SM

4000

(13.12)


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Aug 2 18:19:02 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.