Table Of Contents
Test Results Tables
This appendix contains tables and checklists to use during the turn-up and test of a Cisco ONS 15540.
Table B-1 Test Results for Cisco ONS 15540 ESP
Test or Procedure Expected Result (After Power-up) NotesTested fiber meets the specifications listed in that section.
Installing Line Card Motherboards and Transponder Modules on page 2-7
The "Status" LED is green.
Installing SM Transponder Modules or MM Transponder Modules on page 2-8
All LEDs on the module are off (default).
All LEDs on the module are off (default).
Use a power meter to confirm that the top OSC port on the motherboard is Tx and the bottom is Rx. Conduct the check for slot 0 as well as slot 1.
The Status LED is green.
The Active LED on the primary processor and the Standby LED on the standby processor are both green.
The alarm LEDs are off.
All modules in the chassis are reported in the proper slot by Cisco IOS software. The modules have the correct hardware version and software version.
Confirm that the interfaces are administratively up.
Verifying Transmit Launch Power and Insertion Losses on page 4-2
Tx optical power and wavelengths are in line with figures in the power specification tables.
Measured power matches the specifications provided.
The laser frequency (channel number) is configured to the proper wavelength.
The test runs error free for 15 minutes.
Alarms are generated for the listed fault conditions.
Expected results (from network design), measured results, and results as seen by Cisco IOS software match.
Active is displayed under the Status field.
2way is displayed under the OSCP St. field.
Channel count, power, power equalization, and OSNR meet the network design requirements.
The test runs error free for 15 minutes.