Table Of Contents
Release Notes for Cisco ONS 15540 ESP
for Cisco IOS Release 12.1(10)EV2Determining the Software Version
New Features in Release 12.1(10)EV2
New Features in Release 12.1(12c)E1
New Features in Release 12.1(12c)E
New Features in Release 12.1(11b)E1
New Features in Release 12.1(11b)E
New Features in Release 12.1(7a)EY3
New Features in Release 12.1(7a)EY2
Obtaining Technical Assistance
Release Notes for Cisco ONS 15540 ESP
for Cisco IOS Release 12.1(10)EV2
This document describes caveats for Cisco IOS Release 12.1(10)EV2 for the Cisco ONS 15540 ESP (Extended Services Platform).
Date: September 30, 2002
Text Part Number: OL-3341-01
Contents
This document includes the following information:
• Caveats
• Obtaining Technical Assistance
Introduction
The Cisco ONS 15540 ESP is an optical transport platform that employs DWDM (dense wavelength division multiplexing) technology. With the Cisco ONS 15540 ESP, users can take advantage of the availability of dark fiber to build a common infrastructure that supports data, SAN (storage area networking), and TDM (time-division multiplexing) traffic. For more information about DWDM technology and applications, refer to the Introduction to DWDM Technology publication and the
Cisco ONS 15540 ESP Planning and Design Guide.System Requirements
This section describes the system requirements for Cisco IOS Release 12.1(10)EV2 and includes the following sections:
• Determining the Software Version
Memory Requirements
The DRAM memory configuration is 128 MB, which is the default for the Cisco ONS 15540 ESP.
Hardware Supported
Table 1 lists the hardware components supported on the Cisco ONS 15540 ESP and the minimum software version required. See the "Determining the Software Version" section for information on determining your software version.
Determining the Software Version
Note We strongly recommend that you use the latest available software release for all Cisco ONS 15540 ESP hardware.
To determine the version of Cisco IOS software currently running on a Cisco ONS 15540 ESP system, log in to the system and enter the show version EXEC command. The following sample output is from the show version command. The software version number is shown on the second line of the sample output.
Switch# show version
Cisco Internetwork Operating System Software
IOS (tm) ONS-15540 Software (ONS15540-I-M), Version 12.1(12c)E1 <Information deleted>
Upgrading the System Image
To ensure proper system functioning, follow the system image upgrading procedure described in the Cisco ONS 15540 ESP Configuration Guide and Command Reference.
Note Always set the configuration register to 0x2102 when upgrading the system image using the config-reg 0x2102 command in configuration mode.
Caution Improper system image upgrades can affect system functioning and redundancy. Always follow the recommended upgrade procedures.
Feature Set Table
The Cisco IOS Release software is packaged in feature sets (also called software images) depending on the platform. Each feature set contains a specific set of Cisco IOS features. Table 2 lists the Cisco IOS software feature sets available for the Cisco ONS 15540 ESP.
Table 2 Feature Sets Supported by the Cisco ONS 15540 ESP
Feature Set 12.1(10)EV2 12.1(12c)E1 12.1(12c)E 12.1(11b)E1 12.1(11b)E 12.1(7a)EY3 12.1(7a)EY2Gigabit Ethernet
X
X
X
X
X
X
X
Fast Ethernet
X
X
X
X
X
X
X
Ethernet
X
X
X
X
X
X
X
ATM OC-3/STM-1, OC-12/STM-4, and OC-48/STM-16
X
X
X
X
X
X
X
X
X
X
X
X
X
X
POS3
X
X
X
X
X
X
X
Coupling link
X
X
X
X
X
X
X
Fibre Channel (1 Gbps)
X
X
X
X
X
X
X
Fibre Channel (2 Gbps)
X
X
X
X
X
X
X
FDDI4
X
X
X
X
X
X
X
ESCON5 SM (200 Mbps)
X
X
X
X
X
X
X
FICON6 (800 Mbps)
X
X
X
X
X
X
X
Token Ring
X
X
X
X
X
X
X
SNMP
X
X
X
X
X
X
X
CiscoView
X
X
X
X
X
X
X
Cisco Transport Manager
X
X
X
X
X
X
X
IP packets
X
X
X
X
X
X
X
OSCP7
X
X
X
X
X
X
X
APS8 protocol packets
X
X
X
X
X
X
X
Point-to-point
X
X
X
X
X
X
X
Hubbed ring
X
X
X
X
X
X
X
Meshed ring
X
X
X
X
X
X
X
Sysplex
X
X
X
X
X
X
X
GDPS9
X
X
X
X
X
X
X
CDL over 10-GE
X
1 SONET = Synchronous Optical Networking
2 SDH = Synchronous Digital Hierarchy
3 POS = Packet over SONET
4 FDDI = Fiber Distributed Data Interface
5 ESCON = Enterprise Systems Connection
6 FICON = Fiber Connection
7 OSCP = Optical Supervisory Channel Protocol
8 APS = Automatic Protection Switching
9 GDPS = Geographically Dispersed Parallel Sysplex
New and Changed Information
This section lists new features that appear in this and previous releases of Cisco IOS Release 12.1. The new features are sorted by release number.
New Features in Release 12.1(10)EV2
The following new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(10)EV2:
•Hardware:
–Non-protected dual subslot motherboard for Cisco ONS 15540 ESP
–10-GE transponder module
–ITU direct insertion module
•Software:
–CDL over 10-GE
New Features in Release 12.1(12c)E1
No new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(12c)E1.
New Features in Release 12.1(12c)E
No new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(12c)E.
New Features in Release 12.1(11b)E1
No new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(11b)E1.
New Features in Release 12.1(11b)E
The following new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(11b)E:
•Extended range transponder modules supporting the following transceivers:
–ESCON and SONET OC-3 MM (1310 nm)
–Gigabit Ethernet and Fibre Channel (1 Gbps) MM (850 nm)
–Gigabit Ethernet and Fibre Channel (1 Gbps) SM (1310 nm)
–Fibre Channel (2 Gbps) MM (850 nm)
–Fibre Channel (2 Gbps) SM (1310 nm)
–SONET OC-12 SM (1310 nm)
–SONET OC-48 SM (1310 nm)
New Features in Release 12.1(7a)EY3
The following new software features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(7a)EY3:
•Cisco IOS software on the processor.
•Autoconfiguration at startup.
•Autodiscovery of network neighbors.
•Online diagnostics.
•Processor redundancy provided by arbitrations of processor status and switchover in case of failure without loss of connections.
•Autosynchronization of startup and running configurations.
•Support for in-service software upgrades.
•Support for per-channel APS (Automatic Protection Switching) in point-to-point and ring topologies using redundant subsystems that monitor link integrity and signal quality.
•Unidirectional and bidirectional 1+1 path switching.
•System configuration and management through the CLI (command-line interface), accessible through an Ethernet connection or console terminal.
•Optical power monitoring on the transport side, digital monitoring on both client and transport side, and per-channel transponder in-service and out-of-service loopback (client and transport sides).
•Optional out-of-band management of other Cisco ONS 15540 ESP systems on the network through the OSC (optical supervisory channel).
•Support for network management systems that use SNMP. Its capabilities include configuration management, fault isolation, topology discovery, and path trace.
New Features in Release 12.1(7a)EY2
The following new features are available for the Cisco ONS 15540 ESP in Cisco IOS Release 12.1(7a)EY2:
•Cisco IOS software on the processor.
•Autoconfiguration at startup.
•Autodiscovery of network neighbors.
•Online diagnostics.
•Processor redundancy provided by arbitrations of processor status and switchover in case of failure without loss of connections.
•Autosynchronization of startup and running configurations.
•Support for in-service software upgrades.
•Support for per-channel APS (Automatic Protection Switching) in point-to-point and ring topologies using redundant subsystems that monitor link integrity and signal quality.
•Unidirectional and bidirectional 1+1 path switching.
•System configuration and management through the CLI (command-line interface), accessible through an Ethernet connection or console terminal.
•Optical power monitoring on the transport side, digital monitoring on both client and transport side, and per-channel transponder in-service and out-of-service loopback (client and transport sides).
•Optional out-of-band management of other Cisco ONS 15540 ESP systems on the network through the OSC (optical supervisory channel).
•Support for network management systems that use SNMP. Its capabilities include configuration management, fault isolation, topology discovery, and path trace.
Caveats
This section lists the caveats and corrected caveats for each release. Use Table 3 to determine the status of a particular caveat. In the tables, "C" indicates a corrected caveat, and "O" indicates an open caveat.
This section describes the caveats in the Cisco ONS 15540 ESP.
Symptom: If you attempt to change or edit a threshold in the threshold list that is already associated with an interface, the threshold is applied to that interface even when no changes are made to it. Usually the change in error counts are more important than the error counters themselves.
Workaround: Issue the clear counters command.
Symptom: If CiscoView files are extracted on a Flash disk (disk0: or disk1:), the package does not work.
Workaround: Install CiscoView on a Flash PC Card (slot0: or slot1:).
Symptom: When there is a constant stream of loss of sync alarms, a port fail notification is not generated.
Although both signal failure and signal degrade thresholds are applied, only signal degrade is observed. The signal failure threshold is monitored by hardware registers. When the signal failure threshold is exceeded, the hardware normally generates a port fail notification. Because the loss of sync alarms are constant, the threshold exceeded cannot generate a port fail notification. The signal degrade is reported because it is monitored by software and does not need any notifications from hardware.
Workaround: Disable and reenable monitoring once with the no monitor/monitor enable command sequence to generate the port fail notification.
Symptom: Upon switchover, the active processor card can become nonresponsive. The processor card Active LED remains on, even though it is no longer actively controlling the system.
Workaround: None
Remove and reinsert the processor card to correct the fault.
Symptom: The ROMMON might continuously loop in an attempt to autoboot a missing system image.
Continuous looping happens when autoboot is configured in the configuration register (0x2102), but the system image corresponding to the system boot filename command in the startup configuration is missing and no alternate system boot filename command is configured for an existing system image.
During normal system functioning, the system first checks for system image file names in the startup configuration system boot filename commands. If there are none, or the images are not valid, the system checks the Flash device in slot0: and then bootflash for loadable images before stopping its attempts to autoboot.
Workaround: Configure at least one system boot filename command for an existing system image on both processor cards before reloading either processor card.
If autoboot looping occurs, issue a console send break command during the first few seconds of a reload attempt to stop autobooting. Then manually boot the system using a valid system image in Flash memory or on the network.
Upgrade the processor card ROMMON image to release 12.1(11r)E3 or later.
Symptom: If during a netboot attempt the processor card fails to netboot or the peer processor card changes its Active/Standby state, any further changes to the peer processor card Active/Standby state are ignored until a reset command is issued at the processor card ROMMON prompt.
Workaround: Issue a reset command at the ROMMON prompt after failing to netboot.
Upgrade the processor card ROMMON image to release 12.1(11r)E3 or later.
Symptom: An error can occur with management protocol processing. Please see the following URL for more information:
http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCdw65903Workaround: None
Symptom: Following a Cisco IOS software crash, a second ROMMON exception might cause the original stack trace to be lost. This happens if a pending PCI (peripheral component interconnect) bus interrupt was in progress but was not handled before the IOS crash.
Workaround: Upgrade the processor card ROMMON image to release 12.1(11r)E3 or later.
Symptom: The following errors might occur:
–The 100 Mbps LED for the NME (Network Management Ethernet) port might be on even if the port is connected to an 10 Mbps source. This LED should be on only when connected to a 100 Mbps source.
–The full duplex LED might not stay on even when the port is connected to a full duplex source.
–Auto negotiation of speed and duplex mode might not work when switched from a 10 Mbps source to 100 Mbps source.
–Auto negotiation of speed and duplex mode might not work when switched from a 100 Mbps source to a 10 Mbps source.
Workaround: None.
Symptom: The system power cycles and the standby processor card startup configuration is not synchronized with the active processor card startup configuration. If this occurs, then the previous standby processor card might become the active processor card and a different set of connections might be set up.
The standby processor card startup configuration can become outdated when it is in maintenance mode.
Workaround: Remove the standby processor card from the shelf when it is not in use.
Upgrade the processor card ROMMON image to release 12.1(11r)E3 or later.
Symptom: Loopback cannot be configured on the wave interface of an extended range transponder module if no transceiver is present. The loopback command is accepted but the loopback is not configured.
Workaround: Insert a transceiver before configuring the loopback on the wave interface.
Symptom: When laser safety control is enabled on the OSC wave 0 interface or wave 1 interface, the OSC trunk laser does not shut down when a fiber cut occurs.
Workaround: None
Symptom: Loss of Signal may be encountered before SD (signal degrade) and SF (signal failure) thresholds are exceeded and traffic may still continue to pass transparently.
The loss of signal detection is taken from the OE conversion subsystem which is different from the source of the SD and SF counters. The OE conversion is not gated by its loss of light indication so the data and clock extraction continues and the signal is regenerated transparently. The loss of light sensitivity is a characteristic of the OE conversion unit and it may vary from unit to unit but is always < -30dBm.
Workaround: None.
Symptom: The alarm LED is not raised or cleared by SD/SF indications.
Workaround: None.
Symptom: If the configuration register autoboot field is set to either 0x1 or 0x2 and the first file in bootflash memory is not a loadable system image, then the system continues to try to reboot.
Workaround: Use the send break command on the console CLI to stop the autoboot cycling, and then manually boot a loadable system image. Make sure the first image in bootflash memory is a valid system image.
Upgrade the processor card ROMMON image to release 12.1(11r)E3 or later.
Symptom: With APS Y-cable, SD condition on the working channel does not clear the lower priority manual-switch condition on the protection channel. This caused manual-switch to persist after the SD condition was removed and APS to switch back to the working channel.
Workaround: None.
Symptom: Customer installed mismatching wavelength transponders and did not receive a wavelength mismatch alarm. The Cisco ONS 15540 ESP does not report this condition.
Workaround: None.
Symptom: When the Rx port fiber is removed, ingress alarms are reported and cleared repeatedly. The alarm should not clear and the alarm should be reported only once.
Workaround: None
Symptom: Processor card gets into a nonresponsive state.
Workaround: None
Symptom: No alarm is raised when the transponder channel does not match the channels supported by the mux/demux module.
Workaround: None.
Symptom: CTM is flooded with traps every second when hardware port flap alarms occur.
Workaround: None.
Symptom: The encapsulation fastethernet command fails on multimode transponders. The clock rate 100000 command succeeds but then pings over the signal fail intermittently.
Workaround: None.
Symptom: The OSC intermittently drops IP packets because of an erroneous calculation of the FCS-16 (frame check sequence 16).
Workaround: None.
Symptom: The system image on the standby processor card cannot be upgraded to a new system image because the format of the redundancy messages from the active processor card are not recognized on the standby processor card. The standby processor card fails to boot and returns to ROMMON mode.
Workaround: None.
Symptom: The transparent interface of an extended range transponder module continues to report good signal quality even after the transceiver is removed and reinserted.
Workaround: Perform a shutdown/no shutdown command sequence on the transparent interface.
Symptom: A transparent interface carrying Gigabit Ethernet traffic and configured with gigabit Fibre Channel encapsulation shows good quality signal on the show interfaces transparent command output and does not assert any ingress alarms. The wave interface assert loss of lock and loss of sync alarms.
Workaround: Remove and reinsert the transponder module to bring it to the correct state.
Symptom: LoF (loss of frame) alarms are not reasserted after a shutdown/no shutdown command sequence on both the transparent and wave interfaces on the transponder module.
Workaround: Disable and reenable monitoring on the transparent interface to reassert the alarms.
Symptom: A line laser failure alarm is asserted but not cleared when an extended range transponder module is removed and reinserted. The show facility-alarm status command output shows a message similar to the following:
Source: TranspdrSC 2/3 Severity: MAJOR Description: 2 Line laser failure detected
Workaround: None.
Symptom: The SF (signal failure) alarms are not cleared from the show facility-alarm status command output after monitoring is disabled.
Workaround: None.
Symptom: An ingress LoF alarm on a transparent interface is not asserted when an SEF (severely errored frames) alarm is present due to the alarm priority handling error in driver.
Workaround: A shutdown/no shutdown command sequence on the transparent interface will reassert the ingress LoF alarm.
Symptom: If a Downlink Client interface is configured for CDL but is connected to a non-CDL device, the CDL message channel is down.
Workaround: Ensure Downlink Client interface is configured correctly.
Symptom: Unknown vendor type for Wavepassthru interface in Entity MIB.
Workaround: None.
Symptom: In a configuration where two Cisco ONS 15530 systems are linked to a Cisco ONS 15540 ESP through 10-GE connections, the tengigethernetphy interface on one side is administratively shut down and the ESCON ports are down. However, the ESCON ports associated with the other Cisco ONS 15530 are still up.
Workaround: Shut down the tengigethernetphy interface associated with the second Cisco ONS 15530.
Symptom: Configuring both line and trunk side loopback on the 10-GE trunk card affects the Traffic flow.
Workaround: Reconfigure the 10-GE trunk card with loopback on only line or trunk side, not both. OIR the 10-GE card to restore traffic.
Symptom: CDL hec counters are displayed in the show interface tengigethernetphy when CDL is disabled.
Workaround: None.
Symptom: Traffic is disrupted on bootup and switchover when the client side of the 10-GE trunk card has CDL disabled and both the client side and the trunk side are configured for cdl force hop
Workaround: Use the no cdl defect-indication force hop command on the client side.
Limitations and Restrictions
This section provides limitations and restrictions for Cisco ONS 15540 ESP hardware and software.
Transponder Modules
This section contains limitations and restrictions that apply to transponder modules.
•When you insert the standby transponder module in a y-cable protected configuration, remove the cable from the transponder module before inserting the transponder module into the shelf. Failure to remove the cable might result in errors that can affect the performance of the active signal received by the client equipment.
•CRC errors may occur with 2-Gbps Fibre Channel on single-mode transponders when high input power levels are received from the client laser sources.
Data errors or link-down conditions for 2-Gbps Fibre Channel might occur when used with certain client laser sources. Transmitters in some client GBIC and SFP transceiver units might send large overshoots in optical power with signal bit transitions, causing momentary overload conditions on the transponder client side receiver. The average transmitted power level from the GBIC does not violate the overload specification of the transponder client side receiver, so a power meter does not detect the overload.
The workaround is to attenuate the signal from the client equipment to a recommended level of -12 dBm when transmitting 2-Gbps Fibre Channel services.
•If both processor cards are removed, traffic through the system is affected as follows:
–For Type 2 extended range transponder modules, traffic is shut down.
–For 10-GE transponder modules, traffic is shut down.
–Type 1 SM transponder modules and MM transponder modules do not operate reliably. The traffic might be affected.
–In the shutdown state, the Status LED on the line card motherboard turns orange.
Note Traffic on pass through optical channels (which passively pass through the mux/demux modules) are not affected by the removal of the processor cards.
Related Documentation
Refer to the following documents for more information about the Cisco ONS 15540 ESP:
• Cisco ONS 15540 ESP Planning and Design Guide
• Regulatory Compliance and Safety Information for the Cisco ONS 15540 ESP
• Cisco ONS 15540 ESP Hardware Installation Guide
• Cisco ONS 15540 ESP Configuration Guide and Command Reference
• Cisco ONS 15540 ESP Troubleshooting Guide
•Cisco ONS 15540 ESP MIB Quick Reference
• Glossary of Optical Networking Terms
Obtaining Documentation
The following sections explain how to obtain documentation from Cisco Systems.
World Wide Web
You can access the most current Cisco documentation on the World Wide Web at the following URL:
Translated documentation is available at the following URL:
http://www.cisco.com/public/countries_languages.shtml
Documentation CD-ROM
Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.
Ordering Documentation
Cisco documentation is available in the following ways:
•Registered Cisco Direct Customers can order Cisco product documentation from the Networking Products MarketPlace:
http://www.cisco.com/cgi-bin/order/order_root.pl
•Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store:
http://www.cisco.com/go/subscription
•Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco corporate headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).
Documentation Feedback
If you are reading Cisco product documentation on Cisco.com, you can submit technical comments electronically. Click Leave Feedback at the bottom of the Cisco Documentation home page. After you complete the form, print it out and fax it to Cisco at 408 527-0730.
You can e-mail your comments to bug-doc@cisco.com.
To submit your comments by mail, use the response card behind the front cover of your document, or write to the following address:
Cisco Systems
Attn: Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883We appreciate your comments.
Obtaining Technical Assistance
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.
Cisco.com
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.
Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you to
•Streamline business processes and improve productivity
•Resolve technical issues with online support
•Download and test software packages
•Order Cisco learning materials and merchandise
•Register for online skill assessment, training, and certification programs
You can self-register on Cisco.com to obtain customized information and service. To access Cisco.com, go to the following URL:
Technical Assistance Center
The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC Web Site and the Cisco TAC Escalation Center.
Inquiries to Cisco TAC are categorized according to the urgency of the issue:
•Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.
•Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.
•Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.
•Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.
Which Cisco TAC resource you choose is based on the priority of the problem and the conditions of service contracts, when applicable.
Cisco TAC Web Site
The Cisco TAC Web Site allows you to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC Web Site, go to the following URL:
All customers, partners, and resellers who have a valid Cisco services contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to the following URL to register:
http://www.cisco.com/register/
If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com registered user, you can open a case online by using the TAC Case Open tool at the following URL:
http://www.cisco.com/tac/caseopen
If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC Web Site.
Cisco TAC Escalation Center
The Cisco TAC Escalation Center addresses issues that are classified as priority level 1 or priority level 2; these classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer will automatically open a case.
To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to the following URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled; for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). In addition, please have available your service agreement number and your product serial number.
Posted: Sat Nov 6 11:28:54 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.