Release Notes for Cisco ONS 15530
for Cisco IOS Release 12.2(23)SV1
This document describes caveats for Cisco IOS Release 12.2(23)SV1 for the Cisco ONS 15530.
Date: July 31
Text Part Number: OL-4891-05
Contents
This document includes the following information:
• Caveats
• Limitations and Restrictions
• Obtaining Technical Assistance
• Obtaining Additional Publications and Information
Introduction
The Cisco ONS 15530 is a DWDM multiservice aggregation platform that maximizes the carrying capacity of fiber by performing service aggregation of protocols such as ESCON, Fibre Channel, FICON, and Gigabit Ethernet. With the Cisco ONS 15530, users can take advantage of the availability of dark fiber to build a common infrastructure that supports data, SAN (storage area networking), and TDM (time-division multiplexing) traffic. For more information about DWDM technology and applications, refer to the Introduction to DWDM Technology publication and the Cisco ONS 15530 Planning Guide.
System Requirements
This section describes the system requirements for Cisco ONS 15530 IOS Release 12.2(23)SV and includes the following sections:
• Determining the Software Version
Memory Requirements
The DRAM memory configuration is 64 MB, which is the default for the Cisco ONS 15530.
Hardware Supported
Table 1 lists the hardware components supported on the Cisco ONS 15530 and the minimum software version required. See the "Determining the Software Version" section.
Table 1 Cisco ONS 15530 Supported Hardware and Minimum Software Requirements
Component Part Number Description Minimum Software Version RequiredChassis
15530-CHAS-N
15530-CHAS-N chassis, NEBS version
12.1(10)EV1
15530-CHAS-E
15530-CHAS-E chassis, ETSI version
12.1(10)EV1
Power supplies
15530-PWR-AC
120 to 240 VAC power supply
12.1(10)EV1
15530-PWR-DC
Power supply -48 VDC
12.1(10)EV1
CPU switch module
15530-CPU
ONS 15530 CPU switch module
12.1(10)EV1
Carrier motherboard
15530-LCMB-0100
Carrier motherboard (supports OSC, WB-VOA, and PB-OE modules)
12.1(10)EV1
OADM modules without OSC
15530-MDXA-04A0
4-channel Band A
12.1(10)EV1
15530-MDXA-04B0
4-channel Band B
12.1(10)EV1
15530-MDXA-04C0
4-channel Band C
12.1(10)EV1
15530-MDXA-04D0
4-channel Band D
12.1(10)EV1
15530-MDXA-04E0
4-channel Band E
12.1(10)EV1
15530-MDXA-04F0
4-channel Band F
12.1(10)EV1
15530-MDXA-04G0
4-channel Band G
12.1(10)EV1
15530-MDXA-04H0
4-channel Band H
12.1(10)EV1
OADM modules with OSC
15530-MDXB-04A0
4-channel Band A
12.1(10)EV1
15530-MDXB-04B0
4-channel Band B
12.1(10)EV1
15530-MDXB-04C0
4-channel Band C
12.1(10)EV1
15530-MDXB-04D0
4-channel Band D
12.1(10)EV1
15530-MDXB-04E0
4-channel Band E
12.1(10)EV1
15530-MDXB-04F0
4-channel Band F
12.1(10)EV1
15530-MDXB-04G0
4-channel Band G
12.1(10)EV1
15530-MDXB-04H0
4-channel Band H
12.1(10)EV1
MM transponder line cards with splitter
15530-TSP1-0111
Ch 1-2—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0311
Ch 3-4—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0511
Ch 5-6—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0711
Ch 7-8—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0911
Ch 9-10—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1111
Ch 11-12—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1311
Ch 13-14—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1511
Ch 15-16—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1711
Ch 17-18—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1911
Ch 19-20—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2111
Ch 21-22—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2311
Ch 23- 24—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2511
Ch 25-26—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2711
Ch 27-28—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2911
Ch 29-30—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-3111
Ch 31-32—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
MM transponder line cards without splitter
15530-TSP1-0121
Ch 1-2—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0321
Ch 3-4—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0521
Ch 5-6—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0721
Ch 7-8—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-0921
Ch 9-10—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1121
Ch 11-12—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1321
Ch 13-14—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1521
Ch 15-16—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1721
Ch 17-18—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-1921
Ch 19-20—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2121
Ch 21-22—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2321
Ch 23- 24—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2521
Ch 25-26—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2721
Ch 27-28—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-2921
Ch 29-30—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
15530-TSP1-3121
Ch 31-32—1310-nm MM 16 to 622 Mbps with SC
12.1(10)EV1
SM transponder line cards with splitter
15530-TSP1-0112
Ch 1-2—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0312
Ch 3-4—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0512
Ch 5-6—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0712
Ch 7-8—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0912
Ch 9-10—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1112
Ch 11-12—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1312
Ch 13-14— 1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1512
Ch 15-16—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1712
Ch 17-18—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1912
Ch 19-20—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2112
Ch 21-22—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2312
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2512
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2712
Ch 25-26—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2912
Ch 27-28—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-3112
Ch 29-30 —1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
SM transponder line cards without splitter
15530-TSP1-0122
Ch 1-2—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0322
Ch 3-4—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0522
Ch 5-6—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0722
Ch 7-8—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-0922
Ch 9-10—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1122
Ch 11-12—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1322
Ch 13-14—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1522
Ch 15-16—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1722
Ch 17-18—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-1922
Ch 19-20—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2122
Ch 21-22—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2322
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2522
Ch 23- 24—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2722
Ch 25-26—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-2922
Ch 27-28—1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
15530-TSP1-3122
Ch 29-30 —1310-nm SM 16 Mbps to 2.5 Gbps with SC
12.1(10)EV1
Aggregation cards
15530-LCMB-0200
ONS 15530 10-port ESCON aggregation card
12.1(10)EV1
15530-FCGE-8P
ONS 15530 8-port Fibre Channel/Gigabit Ethernet aggregation card
12.1(12c)EV
15530-FC-4P
ONS 15530 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
2.5-Gbps ITU trunk cards
15530-ITU3-0110
ONS 15530 Ch 1/2 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0310
ONS 15530 Ch 3/4 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0510
ONS 15530 Ch 5/6 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0710
ONS 15530 Ch 7/8 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0910
ONS 15530 Ch 9/10 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1110
ONS 15530 Ch 11/12 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1310
ONS 15530 Ch 13/14 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1510
ONS 15530 Ch 15/16 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1710
ONS 15530 Ch 17/18 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-1910
ONS 15530 Ch 19/20 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2110
ONS 15530 Ch 21/22 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2310
ONS 15530 Ch 23/24 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2510
ONS 15530 Ch 25/26 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2710
ONS 15530 Ch 27/28 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-2910
ONS 15530 Ch 29/30 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-3110
ONS 15530 Ch 31/32 2.5-Gbps ITU trunk card MU with splitter
12.1(12c)EV
15530-ITU3-0120
ONS 15530 Ch 1/2 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0320
ONS 15530 Ch 3/4 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0520
ONS 15530 Ch 5/6 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0720
ONS 15530 Ch 7/8 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-0920
ONS 15530 Ch 9/10 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1120
ONS 15530 Ch 11/12 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1320
ONS 15530 Ch 13/14 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1520
ONS 15530 Ch 15/16 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1720
ONS 15530 Ch 17/18 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-1920
ONS 15530 Ch 19/20 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2120
ONS 15530 Ch 21/22 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2320
ONS 15530 Ch 23/24 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2520
ONS 15530 Ch 25/26 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2720
ONS 15530 Ch 27/28 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-2920
ONS 15530 Ch 29/30 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
15530-ITU3-3120
ONS 15530 Ch 31/32 2.5-Gbps ITU trunk card MU without splitter
12.1(12c)EV
10-Gbps ITU trunk cards with splitter (1550 nm)
15530-ITU2-0110
CH 1—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0210
CH 2—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0310
CH 3—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0410
CH 4—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0510
CH 5—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0610
CH 6—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0710
CH 7—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0810
CH 8—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-0910
CH 9—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1010
CH 10—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1110
CH 11—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1210
CH 12—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1310
CH 13—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1410
CH 14—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1510
CH 15—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1610
CH 16—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1710
CH 17—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1810
CH 18—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-1910
CH 19—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2010
CH 20—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2110
CH 21—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2210
CH 22—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2310
CH 23—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2410
CH 24—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2510
CH 25—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2610
CH 26—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2710
CH 27—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2810
CH 28—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-2910
CH 29—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3010
CH 30—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3110
CH 31—10-Gbps ITU trunk card with splitter
12.1(10)EV1
15530-ITU2-3210
CH 32—10-Gbps ITU trunk card with splitter
12.1(10)EV1
10-Gbps ITU trunk cards without splitter
(1550 nm)15530-ITU2-0120
CH 1—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0220
CH 2—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0320
CH 3—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0420
CH 4—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0520
CH 5—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0620
CH 6—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0720
CH 7—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0820
CH 8—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-0920
CH 9—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1020
CH 10—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1120
CH 11—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1220
CH 12—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1320
CH 13—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1420
CH 14—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1520
CH 15—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1620
CH 16—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1720
CH 17—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1820
CH 18—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-1920
CH 19—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2020
CH 20—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2120
CH 21—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2220
CH 22—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2320
CH 23—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2420
CH 24—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2520
CH 25—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2620
CH 26—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2720
CH 27—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2820
CH 28—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-2920
CH 29—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3020
CH 30—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3120
CH 31—10-Gbps ITU trunk card without splitter
12.1(10)EV1
15530-ITU2-3220
CH 32—10-Gbps ITU trunk card without splitter
12.1(10)EV1
10-GE uplink card
15530-10GE-UPLINK
ONS 15530 10-Gbps uplink, 1310nm with SC
12.1(10)EV1
WB-VOA module
15500-VOA-0100
Single wide-band variable optical attenuator
12.1(10)EV1
15500-VOA-0200
Dual wide-band variable optical attenuator
12.1(10)EV1
Single-band PB-OE module
15500-PEQ-01A0
Single-band optical equalizer Band A
12.1(10)EV1
15500-PEQ-01B0
Single-band optical equalizer Band B
12.1(10)EV1
15500-PEQ-01C0
Single-band optical equalizer Band C
12.1(10)EV1
15500-PEQ-01D0
Single-band optical equalizer Band D
12.1(10)EV1
15500-PEQ-01E0
Single-band optical equalizer Band E
12.1(10)EV1
15500-PEQ-01F0
Single-band optical equalizer Band F
12.1(10)EV1
15500-PEQ-01G0
Single-band optical equalizer Band G
12.1(10)EV1
15500-PEQ-01H0
Single-band optical equalizer Band H
12.1(10)EV1
Dual-band PB-OE module
15500-PEQ-02AB
Dual band optical equalizer Band AB
12.1(10)EV1
15500-PEQ-02CD
Dual band optical equalizer Band CD
12.1(10)EV1
15500-PEQ-02EF
Dual band optical equalizer Band EF
12.1(10)EV1
15500-PEQ-02GH
Dual band optical equalizer Band GH
12.1(10)EV1
Protection switch module
15530-PSM-01
ONS 15530 protection switch module
12.1(12c)EV
Pluggable SFP optics
15500-XVRA-10A1
Low band (16 to 200 Mbps) variable rate, MM (1310 nm) with LC
12.1(12c)EV3
15500-XVRA-10B1
Low band (16 to 200 Mbps) variable rate, SM
(1310 nm) with LC12.1(12c)EV3
15500-XVRA-11B1
Mid band (200 to 1250 Mbps) variable rate, SM
(1310 nm) with LC
12.1(12c)EV3
15500-XVRA-12B1
High band (1.062 Gbps to 2.5 Gbps) variable rate, SM
(1310 nm) with LC
12.1(12c)EV3
15500-XVRA-02C1
Gigabit Ethernet1 , Fibre Channel (1 Gbps)2 , FICON (1 Gbps)
12.1(12c)EV
15500-XVRA-03B1
Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), ISC-3 links compatibility mode
12.1(12c)EV
15500-XVRA-03B2
Fibre Channel (1-Gbps and 2-Gbps)
12.1(12c)EV
15454-SFP-GEFC-SX
Fibre Channel (2-Gbps), Fibre Channel (1-Gbps), 1000BASE-LX Ethernet
12.1(12c)EV
AC cables
15500-CAB-AC=
AC North America (spare)
12.1(10)EV1
15500E-CAB-ACA=
ONS 15530 ETSI AC cable, Australia (spare)
12.1(10)EV1
15500E-CAB-ACE=
ONS 15530 ETSI AC cable, Europe (spare)
12.1(10)EV1
15500E-CAB-ACU=
ONS 15530 ETSI AC cable, UK (spare)
12.1(10)EV1
15500E-CAB-ACI=
ONS 15530 ETSI AC cable, Italy (spare)
12.1(10)EV1
15500E-CAB-ACR=
ONS 15530 ETSI AC cable, Argentina (spare)
12.1(10)EV1
Blank panel cover
15530-COV-MUX=
OADM blank panel cover
12.1(10)EV1
15530-COV-SLOT=
Full slot panel cover
12.1(10)EV1
15530-COV-PWR=
Power supply blank panel cover
12.1(10)EV1
15530-COV-OSC=
OSC blank panel cover
12.1(10)EV1
Fan assembly
15530-FT01=
Fan assembly (spare)
12.1(10)EV1
Air ramp baffle
15530-BAF-E=
Air baffle (spare) for 15530-CHAS-E chassis
12.1(10)EV1
CompactFlash card
MEM-15530FLC32M=
CompactFlash card 32 MB
12.1(10)EV1
Rack mount kit
15530-RKMT-E=
Chassis rack mount kit for 15530-CHAS-E
12.1(10)EV1
15530-RKMT-N23=
Chassis rack mount kit for 15530-CHAS-N (23 inch rack)
12.1(10)EV1
15530-RKMT-N19=
Chassis rack mount kit for 15530-CHAS-N (19 inch rack)
12.1(10)EV1
1 1000BASE-SX
2 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards
3 1000BASE-LX
4 FC-0-100-SM-LC-S standard
Determining the Software Version
Note We strongly recommend that you use the latest available software release for all Cisco ONS 15530 hardware.
To determine the version of Cisco IOS software currently running on a Cisco ONS 15530 system, log in to the system and enter the show version EXEC command. The following sample output is from the show version command. The software version number is shown on the second line of the sample output.
Switch# show version
Cisco Internetwork Operating System Software
IOS (tm) ONS-15530 Software (ONS15530-I-M), Version 12.2(23)SV <Information deleted>
Upgrading the System Image
To ensure proper system functioning, follow the system image upgrading procedure described in the Cisco ONS 15530 Software Upgrade Guide.
You can find the system images for the Cisco ONS 15530 at the following URL:
http://www.cisco.com/kobayashi/sw-center/sw-optical.shtml
Note Always set the configuration register to 0x2102 when upgrading the system image using the config-reg 0x2102 command in configuration mode.
Caution Improper system image upgrades can affect system functioning and redundancy. Always follow the recommended upgrade procedures.
Feature Set Table
The Cisco IOS Release software is packaged in feature sets (also called software images) depending on the platform. Each feature set contains a specific set of Cisco IOS features. Table 2 lists the Cisco IOS software feature sets available for the Cisco ONS 15530.
Table 2 Feature Sets Supported by the Cisco ONS 15530
Feature Set Introduced in This ReleaseInband message channel
12.1(10)EV2
Gigabit Ethernet
12.1(10)EV2
Fast Ethernet
12.1(10)EV2
Ethernet
12.1(10)EV2
ATM OC-3/STM-1, OC-12/STM-4, and OC-48/STM-16
12.1(10)EV2
12.1(10)EV2
POS3
12.1(10)EV2
IBM Sysplex coupling link
12.1(10)EV2
Fibre Channel (1 Gbps)
12.1(10)EV2
Fibre Channel (2 Gbps)
12.1(10)EV2
FDDI4
12.1(10)EV2
ESCON5 aggregation (2.5 Gbps)
12.1(10)EV2
FICON6 (1 Gbps)
12.1(10)EV2
FICON (2 Gbps)
12.1(10)EV2
Token ring
12.1(10)EV2
SNMP
12.1(10)EV2
CiscoView
12.1(10)EV2
Cisco Transport Manager
12.1(10)EV2
IP packets
12.1(10)EV2
OSCP7
12.1(10)EV2
APS8 channel protocol
12.1(10)EV2
Point-to-point
12.1(10)EV2
Hubbed ring
12.1(10)EV2
Meshed ring
12.1(10)EV2
IBM Sysplex ETR/CLO9
12.1(10)EV2
1-Gbps Fibre Channel/FICON aggregation into 2.5 Gbps
12.1(12c)EV
1-Gbps IBM Sysplex Coupling Link aggregation into 2.5 Gbps
12.2(18)SV
Gigabit Ethernet aggregation (2.5 Gbps)
12.1(12c)EV
Buffer credit support on the 8-port FC/GE aggregation card
12.2(18)SV
2-Gbps Fibre Channel protocol monitoring on transponder line cards
12.2(18)SV
2-Gbps FICON protocol monitoring on transponder line cards
12.2(18)SV
Functional image version diagnostics
12.2(18)SV
Autonegotiation for Gigabit Ethernet between the 8-port FC/GE aggregation card and the client equipment
12.2(18)SV
ISC links compatibility mode aggregation (2.5 Gbps)
12.2(18)SV
2-Gbps ISC links peer mode protocol monitoring on transponder line cards
12.2(22)SV
ISC-3 peer mode (1-Gbps and 2-Gbps) support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
2-Gbps Fibre Channel/FICON aggregation into 2.5-Gbps signals on 4-port 1-Gbps/2-Gbps FC aggregation cards
12.2(23)SV
Buffer credit support on the 4-port 1-Gbps/2-Gbps FC aggregation card
12.2(23)SV
Support for 1-Gbps ISC links peer mode on the transponder line card
12.2(23)SV
1 SONET = Synchronous Optical Networking
2 SDH = Synchronous Digital Hierarchy
3 POS = Packet over SONET
4 FDDI = Fiber Distributed Data Interface
5 ESCON = Enterprise Systems Connection
6 FICON = Fiber Connection
7 OSCP = Optical Supervisory Channel Protocol
8 APS = Automatic Protection Switching
9 ETR/CLO = external timer reference/control link oscillator
New and Changed Information
This section lists new features that appear in this and previous releases of Cisco IOS Release 12.2. The new features are sorted by release number.
New Features in Release 12.2(23)SV
The following new hardware is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(23)SV:
•4-port 1-Gbps/2-Gbps FC aggregation card
The following new software feature is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(23)SV:
•ISC-3 1-Gbps (peer mode) support on all ISC interfaces, except the 8-port FC/GE aggregation card.
New Features in Release 12.2(22)SV
The following new software feature is available for the Cisco ONS 15530 in Cisco IOS Release 12.2(22)SV:
•2-Gbps ISC peer mode protocol monitoring on 2.5-Gbps transponder line cards
New Features in Release 12.2(18)SV2
No new features are available for this release.
New Features in Release 12.2(18)SV1
No new features are available for this release.
New Features in Release 12.2(18)SV
The following new software features are available for the Cisco ONS 15530 in Cisco IOS Release 12.2(18)SV:
•Autonegotiation between the 8-port FC/GE aggregation card and the client equipment for Gigabit Ethernet traffic
Note The 8-port FC/GE aggregation card does not support end-to-end pass through of autonegotiation parameters in the current release.
•ISC links compatibility mode aggregation (2.5 Gbps)
•Buffer credits for Fibre Channel distance extension
•2-Gbps Fibre Channel protocol monitoring
Note 2-Gbps Fibre Channel protocol monitoring requires transponder functional image
release 1.A3.•2-Gbps FICON protocol monitoring
•Data file with upgrade information for the ROMMON and functional images
•show upgrade-info functional-image command
•negotiation auto command
•flow control command
Caveats
This section describes open and resolved severity 1 and 2 caveats and some severity 3 caveats. The "Open Caveats" section lists open caveats that apply to the current release and may apply to previous releases. The "Resolved Caveats" sections list caveats resolved in a particular release, but open in previous releases.
Resolved Caveats in Release 12.2(23)SV1
•CSCef68324
Cisco Internetwork Operating System (IOS) software is vulnerable to a Denial of Service (DoS) and potentially an arbitrary code execution attack from a specifically crafted IPv6 packet. The packet must be sent from a local network segment. Only devices that have been explicitly configured to process IPv6 traffic are affected. Upon successful exploitation, the device may reload or be open to further exploitation.
Cisco has made free software available to address this vulnerability for all affected customers.
More details can be found in the security advisory that is posted at http://www.cisco.com/warp/public/707/cisco-sa-20050729-ipv6.shtml.
Open Caveats in Release 12.2(23)SV
•CSCdz59146
Symptom: The ethernetdcc interface loses connectivity when splitter protection is configured and the waveethernetphy interface is shut down while the protection wavepatch interface is active and the working wavepatch interface is down.
Workaround: Do not shut down the waveethernetphy interface when the working wavepatch interface is down.
•CSCea52092
Symptom: After booting the system, optical power coming out of the OSC module seems to be null even though the laser is enabled.
Workaround: Perform an online removal and insertion of the OSC module or carrier motherboard.
•CSCec25368
Symptom: The values returned for entPhysicalVendorType and entPhysicalName are wrong when a low-band single-mode SFP is present in an ESCON aggregation card. The values returned show a low-band multimode SFP instead.
Workaround: None.
•CSCec45305
Symptom: If the transparent interface on a multimode transponder line card is configured for Sysplex ETR traffic (encap sysplex etr command), the show interfaces transparent command output shows that forward laser control is set to off. Forward laser control is automatically enabled for Sysplex ETR.
Workaround: Add client input traffic and the trunk side laser will function.
•CSCed28094
Symptom: End-to-end GE autonegotiation is not supported by the 8-port FC/GE aggregation card.
Link defects such as a broken fiber from the 8-port FC/GE aggregation card to the client device at one end, which are not directly detected by the Cisco ONS 15530 and cause the client at one end to initiate autonegotiation, are not propagated to the client at the other end.
Any upper-layer processes that depend on bidirectional defect detection and propagation at the transport level might fail for certain classes of link defects.
Workaround: None.
•CSCee84190
Symptom: CRC-errored, dropped, out-of-order, or duplicated frames might be transmitted by ports on 4-port 1-Gbps/2-Gbps FC aggregation cards that have symmetric-mode flow-control configured and active if the client device connected to the remote port is operating in asymmetric credit mode.
The remote peer Cisco ONS 15530 logs the EXCESS_FRAME_ALM alarm message during the errors, or prior to the occurrence of the errors, if conditions with potential to cause the error are detected on the link.
Conditions: This defect note is applicable only if all of the following are true:
–Flow control is disabled and the link runs error-free.
–Flow control is enabled and the client device sees errors transmitted from the port on 4-port 1-Gbps/2-Gbps FC aggregation card.
–Symmetric mode is configured on the 4-port 1-Gbps/2-Gbps FC aggregation card, and you see flow-control (symmetric) in the show interface command output.
–If the peer card is a 4-port 1-Gbps/2-Gbps FC aggregation card, EXCESS_FRAME_ALM alarm is detected on the remote peer Cisco ONS 15530.
–If buffer credit sizes are configurable and readable on the end clients, and the credit numbers on both ends are not the same.
–The transmitted errors are not traceable to Tx CRC errors on the interface.
–The transmitted errors are not traceable to hardware data parity errors (QDR PARITY error count in the show controller command output.
Workaround: Configure asymmetric mode on all the 4-port 1-Gbps/2Gbps FC aggregation card ports in the affected link. [Symmetric mode is the factory default]. Or, wherever feasible, configure equal buffer credits on the client devices at both ends of the FC/FICON link. Either symmetric or asymetric mode configuration on the 4-port 1-Gbps/2Gbps FC aggregation card work well.
•CSCef28950
Symptom: The frame and bit 5-minute input and output rates are missing in the show interface command output of twogigabitphy interfaces on the 4-port 1-Gbps/2-Gbps FC aggregation cards configured for encapsulation for Sysplex ISC.
Workaround: None.
•CSCef28967
Symptom: Tx CRC counts are displayed in the show interface command output of twogigabitphy interfaces on the 4-port 1-Gbps/2-Gbps FC aggregation cards configured for encapsulation for Sysplex ISC, even though these counts are not monitored.
Workaround: Ignore the Tx CRC count in the show interface command output for ISC encapsulation.
•CSCin79007
Symptom: The client laser disables if an OIR is performed when keepalive timeout exists on the interface. The laser is enabled when the keepalive timeout condition is cleared, but disables whenever keepalive timeout condition is asserted. Ideally, the client laser shut down due to keepalive timeout should only be seen under the following conditions:
–The portgroup is not cross-connected to a trunk port.
–Forward laser control (FLC) is configured on the client interface.
Condition: This behavior is seen only on the x/0/0 interface of the 4-port 1-Gbps/2Gbps FC aggregation card if it is removed and reinserted when the interface is in keepalive timeout condition.
Workaround:Change the encapsulation to a different value and then back to the required encapsulation value.
Resolved Caveats in Release 12.2(23)SV
•CSCed38657
Symptom: DWDM links set at a 196.608-Mbps rate, or an uncommon rate close to this, may not work properly on the 2.5-Gbps transponder line card. Link initialization failures and bit errors may occur.
Workaround: None.
•CSCee24673
Symptom: High capacity counters are not implemented but are needed.
Workaround: None.
•CSCee34107
Symptoms: APS behavior for the aps clear command is inconsistent with the standard behavior when the following conditions occur:
–Traffic runs from the working link (link A) and you perform a manual switch to the protected link (link B), causing traffic to switch to link B.
–You enter the aps clear command for the aps-group; link A becomes active, regardless of whether the APS group is configured revertively or nonrevertively.
Workaround: None.
•CSCee59383
Symptom: The entitySensorMIB is not implemented.
Workaround: None.
•CSCeb70408
Symptom: The IDPROM values from the high band single-mode SFPs are not readable. The SFPs cannot be configured and cannot be used.
Workaround: None.
•CSCin73872
Symptom: The command for configuring optical thresholds on a voain interface is broken in Cisco IOS Release 12.2(22)SV for the Cisco ONS 15530. The command should be in the form:
optical threshold power receive after-attenuation [low|high] [alarm|warning] <val>
But in software release 12.2(22)SV only the following command can be specified in the interface configuration mode:
optical threshold power receive [low|high] [alarm|warning] <val>
The command is stored in an earlier format in the running configuration for the interface; hence upon reloading the chassis these threshold configurations are lost.
Workaround: Configure the optical threshold using this format:
optical threshold power receive [low|high] [alarm|warning] <val>
If the chassis has to be reloaded, then reconfigure the threshold command again when the box is rebooted.
•CSCin78329
Symptom: Power-on diagnostics may fail the credit-buffer-memory test for the 8-port FC/GE aggregation card on the first boot after power cycling the box. Subsequent reboots without power cycling pass the test. These test failures are spurious and can be ignored.
Workaround: Upgrade you Cisco ONS 15530 software to Cisco IOS Release 12.2(23)SV or later.
Resolved Caveats in Release 12.2(22)SV
•CSCec14447
Symptom: The 8-port GE/FC aggregation card laser is not in the proper state when a Tx-CRC threshold has been exceeded and FLC is configured.
Workaround: Issue the shutdown/no shutdown command sequence on the affected interface.
•CSCec42573
Symptom: In a y-cable APS configuration, interfaces on the 8-port GE/FC aggregation card configured for FICON encapsulation change to GE encapsulation when the saved configuration file is copied to the running configuration.
Workaround: Change the encapsulation back to FICON.
•CSCed33451
Symptom: After configuring a patch between a wavepatch interface and a wdmrelay interface, issuing a show connect intermediate command results in spurious memory access.
Workaround: Do not issue the show connect intermediate command when a patch between a wavepatch interface and a wdmrelay interface is configured.
•CSCed33852
Symptom: The system might reload unexpectedly when a faulty optical add/drop multiplexer (OADM) module is present in the chassis.
Workaround: Replace the faulty OADM module.
•CSCin64935
Symptom: A system might reload unexpectedly when you perform an online removal and reinsertion of a wide-band variable optical attenuator (WB-VOA) module.
Workaround: Do not remove and reinsert a WB-VOA module.
•CSCin65618
Symptom: The system might reload unexpectedly when you configure the alarm threshold on a waveethernetphy interface of a 2.5-Gbps ITU trunk card.
This symptom occurs after the following events:
1. Configure an alarm threshold list with code violation running disparity (CVRD) signal degrade and failure thresholds and apply it to the waveethernetphy interface.
2. Remove the 2.5-Gbps ITU trunk card, remove the threshold configurations from the threshold list, and reinsert the 2.5-Gbps ITU trunk card.
3. Remove the 2.5-Gbps ITU trunk card again, configure a CVRD degrade threshold, remove the threshold list, and reinsert the 2.5-Gbps ITU trunk card.
After you have performed these steps, the shelf reloads.
Workaround: None.
•CSCin66424
Symptom: An APS switchover from a working interface to a protect interface might not occur for the following modules:
–10-Gbps uplink card
–10-Gbps ITU trunk card
–2.5-Gbps ITU trunk card
This symptom occurs with the following configurations:
–The card is configured for switch fabric based line card protection.
–The interfaces of the card have thresholds groups that are configured for converged data link header error checksum (CDL HEC) errors or cyclic redundancy check (CRC) errors, or both.
–The CDL HEC error thresholds or CRC error thresholds, or both, are exceeded.
Workaround: Do not configure CDL HEC error thresholds, CRC error thresholds, or both. Instead, configure code violation running disparity (CVRD) error thresholds. In a configuration in which an APS switchover of a working interface to a protect interface is based on CDL HEC error thresholds, CRC error thresholds, or both, there is no workaround.
•CSCin68117
Symptom: The CLI does not support patch configurations between oscfilter interfaces and voaout interfaces.
Workaround: None.
•CSCeb18103
Symptom: OSC wave interface that is configured for laser safety control does not recover when the OSC link is down due to Loss of Light.
This occurs after the following sequence of events:
–The OSC wave interface is not configured with laser safety control.
–The OSC wave interface goes down with a Loss of Light condition.
–The OSC wave interfaces at both ends are configured for LSC, with more than 3 seconds elapsed between the configurations.
–The Loss of Light failure is resolved.
This problem does not appear if laser safety control is configured when the OSC wave interface is up.
Workaround: Issue a no laser control safety command and a laser control safety enable command on the OSC wave interface.
•CSCea52092
Symptom: An optical supervisory channel (OSC) module may not provide power even though the laser is enabled after you have booted the shelf.
Workaround: Remove and reinsert the carrier motherboard.
•CSCin60562
Symptom: If a row is created in cApsChanConfigTable using createAndWait, a set operation on an instance of cApsChanConfigIfIndex might modify another instance of that object.
Workaround: Use createAndGo to create the row.
Resolved Caveats in Release 12.2(18)SV2
•CSCeb87507
Symptom: In some instances the system crashes when it attempts to parse IP SNMP related commands.
Workaround: None.
•CSCed05346
Symptom: Bidirectional APS fails when the ethernetdcc interface is used as a message channel for trunk based protection if the PSM is connected directly to a wavepatch interface on an ITU trunk card or transponder line card rather than to the wdm interface on an OADM module.
Workaround: None.
•CSCed22589
Symptom: Link initialization failure due to Loss of Lock might occur for ESCON traffic on some transponder line cards due to a transient failure of the clock recovery unit. Only some transponder line cards are susceptible to this failure and not all. This is an initialization failure and not a run-time failure.
Workaround: None.
Resolved Caveats in Release 12.2(18)SV1
•CSCdz64021
Symptom: While performing an online removal and insertion of a protection card in a y-cable configuration, the local and remote working ports are flooded with CRC errors.
Workaround: Disconnect the standby branch of the y-cable configuration during the insertion of the standby line card or SFP optics.
•CSCec28182
Symptom: Tracebacks related to CPU hog issues are seen when reprogramming the 2.5-Gbps transponder line card functional image.
Workaround: None.
•CSCec36614
Symptom: Performing an online removal and insertion on a tengigethernetphy interface or waveethernetphy interface when loopback is configured causes a loss of the loopback information on the hardware. However, the loopback CLI configuration is still present in the software.
Workaround: Remove and reinsert the line card, and then issue the loopback command.
•CSCec59409
Symptom: Issuing a Ctrl-U when connected to a raw TL1 port causes the system to crash.
Workaround: If a TL1port is unused, apply an IP ACL to the management Ethernet interface that blocks the incoming TCP connections to ports 3082 and 3083.
•CSCec88050
Symptom: Power-on diagnostics fail on the CPU switch module if a 2.5-ITU trunk card is installed in slot 1.
Workaround: None.
Resolved Caveats in Release 12.2(18)SV
•CSCdu53656
A Cisco device running IOS and enabled for the Border Gateway Protocol (BGP) is vulnerable to a Denial of Service (DOS) attack from a malformed BGP packet. The BGP protocol is not enabled by default, and must be configured in order to accept traffic from an explicitly defined peer. Unless the malicious traffic appears to be sourced from a configured, trusted peer, it would be difficult to inject a malformed packet. BGP MD5 is a valid workaround for this problem.
Cisco has made free software available to address this problem. For more details, please refer to this advisory, available at http://www.cisco.com/warp/public/707/cisco-sa-20040616-bgp.shtml.
•CSCdz89270
Symptom: OFC (open fibre control) is not supported with Fibre Channel on the 8-port FC/GE aggregation card. The link might not initialize if an 8-port FC/GE aggregation card is used with older Fibre Channel equipment that employ OFC laser safety mechanisms.
Workaround: None.
•CSCea28131
A Cisco device running IOS and enabled for the Border Gateway Protocol (BGP) is vulnerable to a Denial of Service (DOS) attack from a malformed BGP packet. The BGP protocol is not enabled by default, and must be configured in order to accept traffic from an explicitly defined peer. Unless the malicious traffic appears to be sourced from a configured, trusted peer, it would be difficult to inject a malformed packet. BGP MD5 is a valid workaround for this problem.
Cisco has made free software available to address this problem. For more details, please refer to this advisory, available at http://www.cisco.com/warp/public/707/cisco-sa-20040616-bgp.shtml.
•CSCeb19410
Symptom: An 8-port FC/GE aggregation card client interface laser may be off when it is configured in a disabled y-cable APS group.
Workaround: Enable and then disable the APS group. This activates the client interface laser.
•CSCec03715
Symptom: If the flow identifier on an esconphy interface is changed without deleting the old flow identifier, both the old and the new flow identifiers are present in the lookup table of the ESCON aggregation card. As a result, the old flow identifier cannot be reused on this ESCON aggregation card.
Workaround: Perform an online removal and insertion of the ESCON aggregation card or issue the following sequence of commands in interface configuration mode:
1. no cdl flow identifier
2. cdl flow identifier [OLD IDENTIFIER]
3. no cdl flow identifier
4. cdl flow identifier [NEW IDENTIFIER]
•CSCec34628
Symptom: Continuous optical power monitoring alarms cause memory leaks that lead to bus error exceptions and an unexpected reload.
Workaround: None.
Limitations and Restrictions
This section provides limitations and restrictions for Cisco ONS 15530 hardware and software.
Transponder Line Cards
This section contains limitations and restrictions that apply to transponder line cards.
•CRC errors might occur with 2-Gbps Fibre Channel on single-mode transponders when high input power levels are received from the client laser sources.
Data errors or link-down conditions for 2-Gbps Fibre Channel might occur when used with certain client laser sources. Transmitters in some client GBIC and SFP transceiver units might send large overshoots in optical power with signal bit transitions, causing momentary overload conditions on the transponder client side receiver. The average transmitted power level from the GBIC does not violate the overload specification of the transponder client side receiver, so a power meter does not detect the overload.
The workaround is to attenuate the signal from the client equipment to a recommended level of -12 dBm when transmitting 2-Gbps Fibre Channel services.
•Error-free transmission of some D1 video signals (defined by the SMPTE 259M standard) and test patterns (such as Matrix SDI) cannot be guaranteed by the Cisco 15500 Series because of the pathological pattern in D1 video. This well-known limitation is usually overcome by the D1 video equipment vendor, who uses a proprietary, second level of scrambling. No standards exist at this time for the second level of scrambling.
8-Port FC/GE Aggregation Card
This section contains limitation and restrictions that apply to 8-port FC/GE aggregation cards.
•IFCCs (InterFace Control Checks) are generated while extending the distance between an IBM mainframe and IBM 9032 Model 5 ESCON Director via FICON using 8-port FC/GE aggregation card on a Cisco ONS 15530. These IFCCs are seen on the Host side. They occur when the port is configured for FICON without flow control enabled.
The FICON Bridge port (on the ESCON Director) expects to be connected directly to an N_Port of the Host. Therefore, the Bridge port expects the N_Port to send a minimum of six Primitive Signals (Idles and R_RDYs) between frames. Anything less than six Primitive Signals causes IFCCs to be generated on the ESCON Director, which in turn are logged on the Host. The 8-port FC/GE aggregation card is pure transport and needs to delete and insert one IPG for frequency compensation. Hence, depending on the card, sometimes either five or seven idles are sent between frames. The 8-port FC/GE aggregation card cannot maintain six idles between every frame if the card is on slower side of the clock.
The workaround is to enable flow control using the flow control command on the gigabitphy interfaces.
CPU Switch Modules
This section contains limitations and restrictions that apply to CPU switch modules.
•If both CPU switch modules are removed, all aggregation cards, OSC modules, transponder line cards, ITU trunk cards, and uplink cards are shut down.
Note Traffic on pass through optical channels (which passively pass through the OADM modules) are not affected by the removal of the processor cards.
Related Documentation
Refer to the following documents for more information about the Cisco ONS 15530:
• Regulatory Compliance and Safety Information for the Cisco ONS 15500 Series
• Cisco ONS 15530 Planning Guide
• Cisco ONS 15530 Hardware Installation Guide
•Cisco ONS 15530 Optical Transport Turn-Up and Test Guide
• Cisco ONS 15530 Cleaning Procedures for Fiber Optic Connections
• Cisco ONS 15530 Configuration Guide
• Cisco ONS 15530 Command Reference
• Cisco ONS 15530 System Alarms and Error Messages
• Cisco ONS 15530 Troubleshooting Guide
• Network Management for the Cisco ONS 15530
• Cisco ONS 15530 TL1 Commands
•MIB Quick Reference for the Cisco ONS 15500 Series
•Cisco ONS 15530 Software Upgrade Guide
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation on the World Wide Web at this URL:
http://www.cisco.com/univercd/home/home.htm
You can access the Cisco website at this URL:
International Cisco websites can be accessed from this URL:
http://www.cisco.com/public/countries_languages.shtml
Ordering Documentation
You can find instructions for ordering documentation at this URL:
http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm
You can order Cisco documentation in these ways:
•Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Ordering tool:
http://www.cisco.com/en/US/partner/ordering/index.shtml
•Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).
Documentation Feedback
You can submit e-mail comments about technical documentation to bug-doc@cisco.com.
You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883We appreciate your comments.
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, the Cisco Technical Assistance Center (TAC) provides 24-hour-a-day, award-winning technical support services, online and over the phone. Cisco.com features the Cisco TAC website as an online starting point for technical assistance. If you do not hold a valid Cisco service contract, please contact your reseller.
Cisco TAC Website
The Cisco TAC website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The Cisco TAC website is available 24 hours a day, 365 days a year. The Cisco TAC website is located at this URL:
Accessing all the tools on the Cisco TAC website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a login ID or password, register at this URL:
http://tools.cisco.com/RPF/register/register.do
Opening a TAC Case
Using the online TAC Case Open Tool is the fastest way to open P3 and P4 cases. (P3 and P4 cases are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Case Open Tool automatically recommends resources for an immediate solution. If your issue is not resolved using the recommended resources, your case will be assigned to a Cisco TAC engineer. The online TAC Case Open Tool is located at this URL:
http://www.cisco.com/tac/caseopen
For P1 or P2 cases (P1 and P2 cases are those in which your production network is down or severely degraded) or if you do not have Internet access, contact Cisco TAC by telephone. Cisco TAC engineers are assigned immediately to P1 and P2 cases to help keep your business operations running smoothly.
To open a case by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553-2447For a complete listing of Cisco TAC contacts, go to this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
TAC Case Priority Definitions
To ensure that all cases are reported in a standard format, Cisco has established case priority definitions.
Priority 1 (P1)—Your network is "down" or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Priority 2 (P2)—Operation of an existing network is severely degraded, or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.
Priority 3 (P3)—Operational performance of your network is impaired, but most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.
Priority 4 (P4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online and printed sources.
•Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Go to this URL to visit the company store:
http://www.cisco.com/go/marketplace/
•The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as ordering and customer support services. Access the Cisco Product Catalog at this URL:
http://cisco.com/univercd/cc/td/doc/pcat/
•Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press online at this URL:
•Packet magazine is the Cisco quarterly publication that provides the latest networking trends, technology breakthroughs, and Cisco products and solutions to help industry professionals get the most from their networking investment. Included are networking deployment and troubleshooting tips, configuration examples, customer case studies, tutorials and training, certification information, and links to numerous in-depth online resources. You can access Packet magazine at this URL:
•iQ Magazine is the Cisco bimonthly publication that delivers the latest information about Internet business strategies for executives. You can access iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
•Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:
•Training—Cisco offers world-class networking training. Current offerings in network training are listed at this URL:
http://www.cisco.com/en/US/learning/index.html
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StrataView Plus, TeleRouter, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0502R)
Copyright © 2003-2005 Cisco Systems, Inc. All rights reserved.
Posted: Sun Jul 31 18:02:03 PDT 2005
All contents are Copyright © 1992--2005 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.