This chapter discusses the initial configuration of the Catalyst 1200 series switch and describes how you configure such functions as IP addressing and SNMP management. An IP address must be assigned if you need to use Telnet to connect to the switch or use SNMP network management for the switch. This IP address is configured on the SUM port (sc0) or to any of the interfaces (port 1, FDDI or 3 through 10, Ethernet ports). Up to 16 simultaneous Telnet sessions are possible. If your Telnet station or SNMP network management workstation is on a different network from the switch, a static routing table entry must also be added to the routing table.
This section describes the steps you need to take to configure the switch. Before you can begin your configuration, you need the following information:
To start up and initially configure the switch, perform the following steps:
Step 1 Connect the admin. interface to your terminal. (See the section "Connecting to the Admin. Interface" in the chapter, "Connecting to the Network.")
Step 2 Plug the power cord into the switch. (See the section "Applying Power" in the chapter "Connecting to the Network.")
The following information appears on your screen:
BOOTROM Version 4.1, Dated Mar 4 1994 15:17:09
Booting on May 18 1994 14:09:06
NMP Diagnostics Version 4.1, Dated Apr 11 1994 17:43:53
Model WS-C1201, Board Serial# 100847, H/W Rev 4.0
Copyright (C) cisco Systems 1993, 1994
DMP Diagnostics Version 4.0, Dated Apr 8 1994 10:07:06
Model WS-C1201, Board Serial# 100847, H/W Rev 4.0
Copyright (C) cisco Systems 1993, 1994
cisco Systems Console
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
Sending RARP request with address 00:40:0b:a0:05:b8
Sending bootp request with address: 00:40:0b:a0:05:b8
No bootp or rarp response received
Enter password:
Step 3 At the password prompt, press Return. To add password protection to your system, refer to the section "set password" in the appendix "Command Reference." The following console prompt appears:
Console>
Step 4 Type enable and press Return to enter privileged mode.
Step 5 At the prompt, enter set interface ? to see the set interface command parameters. The following information appears:
Console> (enable) set interface ?
Usage: set interface <if_name|if_number> <ip_address> <net_mask> [broadcast]
set interface <if_name> <slip_address> <dest_address>
set interface <if_name|if_number> <up|down>
Console> (enable)
Refer to the section "set interface" in the appendix "Command Reference."
Step 6 To configure all port as one route group, enter set ip vlan group_number ports IP-address netmask_address broadcast_address, as in the following example:
Console> (enable) set ip vlan 1 1-10 198.133.219.223 255.255.255.0 198.133.219.255
Step 7 At the prompt, enter show interface to check the status of the configuration of the switch:
Console> (enable) show interface
sl0: flags=10<DOWN,POINTOPOINT>
inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0
sc0: flags=863<UP,BROADCAST,RUNNING>
inet 192.122.174.223 netmask 255.255.255.0 broadcast 192.122.174.255
1,3-10: flags=863<UP,BROADCAST,RUNNING>
inet 198.133.219.223 netmask 255.255.255.0 broadcast 198.133.219.255
lo0: flags=808<DOWN,LOOPBACK>
inet 0.0.0.0 netmask 0.0.0.0 broadcast 0.0.0.0
Console> (enable)
Step 8 At the prompt, enter show ip route to display the route table entries for the previous configuration.
Console> show ip route
Total Route Table Entries: 2
DESTINATION GATEWAY FLAGS METRIC AGE INTERFACE
-------------- -------------- ----- ------ --- ---------
199.133.219.128 199.133.219.152 U 0 0 1,3-10
172.20.21.0 172.20.21.2 U 0 0 sc0
Step 9 At the prompt, enter show ip vlan to display the route group configuration.
Console> show ip vlan
Forwarding Fragmentation Redirect RIP Unreachable
---------- ------------- -------- -------- -----------
enabled enabled enabled enabled enabled
IP-Vlan Ports IP-Address Netmask Broadcast Helper-VLANs
---- ------------ --------------- --------------- --------------- ------------
1 1,3-10 199.133.219.152 255.255.255.192 199.133.219.191
Console>
Step 10 Read the remaining sections in this chapter to complete the initial configuration of the switch.
To set the serial (admin.) port baud rate, use the set baud command as in the following example:
Console (enable)> set baud
Usage: set baud <baud_rate>
Console> (enable) set baud ?
Usage: set baud <600|1200|2400|9600|19200|138400>
Console> (enable) set baud 9600
System RS-232 baud rate set.
Password protection is provided in normal mode and privileged mode. To set a password for your switch in normal mode, use the set password command. (Refer to the section "set password" in the appendix "Command Reference.") To set the password protection for your switch in privileged (enable) mode, use the set enablepass command. (Refer to the section "set enablepass" in the appendix "Command Reference.")
Network addresses, subnet masks, broadcast addresses, and SLIP addresses are assigned with the set interface command. (Refer to the section "set interface" in the appendix "Command Reference.")
The Catalyst Switch default configuration is set so that all ports are configured as part of one route group. See the section "Virtual IP ServicesIP VLAN Configuration" in the chapter "Feature Configuration" for a detailed description of configuring bridge groups. To configure the switch with one route group or a number of route groups with different IP addresses, see the section "Virtual IP ServicesIP VLAN Configuration" in the chapter "Feature Configuration."
IP address information can be set using BOOTP. You can configure a BOOTP server with the media access control (MAC) and IP addresses of the switch. When the switch boots, it automatically retrieves the IP address from the BOOTP server.
The switch performs a BOOTP request only if the current IP address is set to 0.0.0.0. (This is the default for a new switch or a switch that has had its configuration file cleared using the clear config all command.)
To configure a workstation as a BOOTP server, you must determine the MAC address of the switch and add that MAC address to the BOOTP configuration file on the server. The following steps provide an example of creating a BOOTP server on a Sun workstation:
Step 1 Install the BOOTP server code on the workstation, if it is not already installed.
Step 2 Use the show module command to obtain the first address in the MAC address range. Figure 5-1 shows an example of the show module command output. Choose the first address in the range on line 1 under the MAC-Address(es) heading. In this example, the correct MAC address is 00-40-0b-90-b8-ff.
Console> (enable) show module
Mod Module-Name Ports Model Serial-Num Hw Fw Sw Status
--- -------------------- ----- -------- ---------- ------ ------ ------ --------
1 2 WS-X5009 000102691 1.40 1.12 1.12 ok
2 24 WS-X5010 000095702 1.302 1.12 1.12 ok
3 24 WS-X5010 000124907 1.304 1.12 1.12 ok
Mod MAC-Address(es)
--- ----------------------------------------
1 00-40-0b-90-b5-00 thru 00-40-0b-90-b8-ff
2 00-40-0b-30-04-f8 thru 00-40-0b-30-05-0f
3 00-40-0b-30-04-08 thru 00-40-0b-30-04-1f
Console> (enable)
Step 3 Add an entry in the BOOTP configuration file (usually /usr/etc/bootptab) for each Catalyst series switch. Press Return after each entry to create a blank line between each entry.
An example entry follows:
catalyst-1:\
ht=ether:\
ha=00400BA00023:\
sm=255.255.255.0:\
ip=192.122.174.224
In this example, ht is the hardware type, ha is the hardware address (use the last address in the MAC-address range), sm is the network subnet mask, and ip is the IP address.
To configure a BootP server on a different network from its BOOTP clients, refer to the "BOOTP Support" section in the "Feature Configuration" chapter.
To manage the switch using an SNMP network management workstation you must do the following:
To set up SNMP community strings, use the set snmp community command as in the following example:
Console> (enable) set snmp community
Usage: set snmp community <access_type> [community_string]
(access_type = read-only|read-write|read-write-all)
Console> (enable) set snmp community read-write hocuspocus
SNMP community string set.
Console> (enable)
SNMP community strings authenticate access to the Management Information Base (MIB) and function as embedded "passwords." For an SNMP message to be processed, the community string must match one of following four community-string modes configured in the switch:
Refer to the section "set snmp community" in the appendix "Command Reference."
When the switch resets or detects an incorrect community string, it sends a trap (or notification message) to a station. The set snmp trap command enters the IP address of the receiving station into the switch's trap receiver table, which can hold up to ten addresses. When you enter addresses in the table, you must specify the community string that appears in the trap message. You can control whether SNMP trap support is in use by using the set snmp trap enable or set snmp trap disable command. (Refer to the section "set snmp rmon" in the appendix "Command Reference.")
The command clear snmp trap clears an entry from the trap receiver table. (Refer to the section "clear snmp trap" in the appendix "Command Reference.")
To configure the admin. port for SLIP, refer to the following sections in the appendix "Command Reference": "set interface" command and the "slip Command."
To configure SLIP, perform the following steps:
Step 1 Telnet into the switch.
Step 2 Enter the following commands:
Console> (enable) set interface sl0 <src_ip_addr> <remote_ip_addr>
.
Console> (enable) slip attach
.
Caution The SLIP connection must use the serial line (admin. port), and this connection causes you to lose your serial connection while the SLIP connection is active. |
After you complete the installation and configure the IP address(es), use the ping command to test for connectivity between the switch and a host. The host can reside anywhere in your network. The ping command sends an echo request to the host specified in the command line.
For example, to test connectivity from the switch to a workstation with an IP address of 192.34.56.5, enter the command ping 192.34.56.5. If the switch receives a response, the following message is displayed:
192.34.56.5 is alive
For more information on the ping command, its available options, and what to expect when there is no response, refer to the section "ping Command" in the appendix "Command Reference."
In general, to verify proper operation of the switch, refer to the appropriate LED descriptions in the chapter "Product Overview."
|