This appendix contains the following information:
Caution There are no operator-serviceable parts in the Catalyst 3900. Refer servicing to qualified personnel. |
If one or more devices (such as a computer) connected to a Catalyst 3900 are unable to communicate with other devices in the network, use the following steps to start the troubleshooting process:
Step 1 Using the network sketch, the label on the cable connected to the device, or other network records, locate the Catalyst 3900 to which the device is connected.
Step 2 If all troubled devices connect to a single feature card, use the feature card documentation to assist in troubleshooting.
Step 3 If you have set up a console session (described in the "Planning for Configuration and Management" chapter), it can be used to determine whether diagnostics have been completed correctly. Refer to the "Resetting the Catalyst 3900" chapter for more information.
Step 4 Observe the LEDs on the Catalyst 3900 front panel. Review the "Understanding the LEDs" section before proceeding with the troubleshooting process.
Step 5 Select a troubleshooting procedure as described in the "Choosing a Troubleshooting Procedure" section.
This section describes the meanings of the various states of the LEDs that are on the Catalyst 3900 and its expansion modules.
Table C-1 lists the Catalyst 3900 status LEDs and their meanings.
LED | Position | State | Meaning |
---|---|---|---|
Power (green) | Left | On | Power supply current is good. |
Off | Power supply current is bad. | ||
Mode (green) | Middle | On | Boot is in progress. |
Off | Catalyst 3900 is working correctly. | ||
Blinking | The FLASH update portion of a TFTP download is in progress. | ||
Fault (Amber) | Right | On | Power-on failure has occurred. |
Off | Catalyst 3900 is working correctly. |
Table C-2 lists the port LEDs and their meanings.
LED | Position | State | Meaning |
---|---|---|---|
INS (insert) | Left | On | Port is inserted. |
Off | Port is not inserted. | ||
ACT (activity) | Right | On | Port is transmitting or receiving. |
Off | Port is idle. |
Table C-3 lists the stack LEDs and their meanings.
LED | Position | State | Meaning |
---|---|---|---|
TX (transmit) | Left | On | Data is being transmitted. |
Off | Data is not being transmitted. | ||
RX (receive) | Middle | On | Data is being received. |
Off | Data is not being received. | ||
ATTACH
| Right | On | Connection to the stack is operational. |
Off | Connection to the stack is not operational. |
There are status LEDs on the front of the 4-port fiber and the 4-port UTP/STP Token Ring modules that indicate the operational status of the ports and the module.
Table C-4 lists the LEDs for the module and their meanings.
Diag | Fault | Meaning |
---|---|---|
On | Off | Diagnostics are in process |
On | On | Expansion module failure has occurred. |
Table C-5 lists the LEDs for the ports and their meanings.
LED | Location | State | Meaning |
---|---|---|---|
Ins | Top | On | Port is inserted into the ring. |
Off | Port is not inserted into the ring. | ||
Act | Bottom | On | Data is being transmitted by the port. |
Off | No activity on the port. |
Table C-6 describes the ATM module status LEDs and their meanings.
Diag (green) | Flt (amber) | Meaning |
---|---|---|
Off | Off | Expansion module is operating normally. |
On | Off | Expansion module is executing diagnostics. |
Flashing | Flashing | Expansion module is testing the LEDs. |
On | On | Expansion module is starting up. |
Off | On | Expansion module failure has occurred. |
Table C-7 describes the ATM port status LEDs and their meanings.
Rx Sync (green) | Signal Loss (amber) | Meaning |
---|---|---|
Off | On | Signal loss. |
On | Off | Connection is synchronized. |
Flashing | Flashing | Loopback test is in progress. |
There is one status LED for the ISL module. It is the DIAG LED. The DIAG LED is lit during power-up diagnostics. If one of the ports on the module fails the diagnostic tests, the DIAG LED will remain lit. Otherwise, it is off.
There are three status LEDs for each of the ports. Table C-8 lists the port LEDs and their meanings.
LED | State | Meaning |
---|---|---|
XMT | On | Port is transmitting. |
RCV | On | Port is receiving. |
LNK/FDX | On | Port is inserted into the network and is functioning in full-duplex mode. This LED is also on briefly at the end of the power-on sequence. |
Use Table C-9 to determine which troubleshooting procedure you should use.
Symptom and LED State | Procedure |
---|---|
All LEDs are off. | A |
Fault LED is on. | B |
None of the devices connected to the Catalyst 3900 can communicate, the Fault LED is off, and the Power LED is on. | C |
Single device connected to the Catalyst 3900 is having trouble communicating. | D |
Feature card's Fault LED is on or device connected to a feature card is experiencing problems. | See the expansion module documentation. |
Use the following procedure if all LEDs are off:
Step 1 Verify that the power cord is connected at both ends and that the power outlet is working.
Step 2 If the power cord is connected correctly, the outlet is working, and the problem persists, the problem is in the Catalyst 3900. Contact the Cisco TAC.
Use the following procedure if the Fault LED (amber) is on:
Step 1 Reset the Catalyst 3900 by disconnecting the power cord. Wait 10 seconds and then reconnect the cord. If the problem goes away, resume using the Catalyst 3900.
Step 2 If you have just downloaded new software, clear NVRAM and reset the Catalyst 3900 using the instructions in the "Resetting the Catalyst 3900" chapter.
Step 3 Reset the Catalyst 3900 and monitor the diagnostic messages for individual port failures. Correct any individual port problems that are detected. If the failing ports are feature card ports, use the feature card documentation to try to correct the problem.
Step 4 If the problem persists, the problem is in the Catalyst 3900. Contact the Cisco TAC.
Use the following procedure if all devices connected to the Catalyst 3900 have communication problems, the Catalyst 3900 Fault LED is off, and the Mode LED is off:
Reset the Catalyst 3900 by disconnecting power cord for 10 seconds. Reconnect the power cord.
Use the following procedure if one device connected to the Catalyst 3900 is having a communication problem, the Catalyst 3900 Fault LED is off, Mode LED is off, and other attached devices can communicate through the Catalyst 3900:
Step 1 Check the port LEDs.
Step 2 If the Connect LED on the failing port is on and the attached device still cannot communicate, do the following:
Step 3 Determine whether the port has been disabled:
Step 4 Restart the communications program on the failed connected device.
Step 5 If the Catalyst 3900 is connected to a Token Ring concentrator, perform the following steps:
Step 6 For each device that is having a communication problem, connect its segment to another Token Ring port on the Catalyst 3900. Try each of the remaining ports to determine whether the problem is in a particular port.
Step 7 The problem does not appear to be in the Catalyst 3900, the cables, or the devices connected to the Catalyst 3900. The problem might be in the network applications or other software running on the devices that are having the communication problem. Refer to the software documentation for software problem determination procedures, or consult your network administrator.
Posted: Tue Oct 12 11:57:29 PDT 1999