This appendix provides information about the following Catalyst 3900 topics:
Table D-1 lists the physical dimensions for a Catalyst 3920.
Physical Feature | Dimension |
---|---|
Rack mounted width | 19 in. (482.6 mm) |
Standalone width | 17.38 in. (441.45 mm) |
Depth | 11.1 in. (281.94 mm) |
Height | 1.72 in. (43.68 mm) |
Weight | 10 lbs (4.54 kg) |
Table D-2 lists the power requirements of the Catalyst 3920. An appropriate power cord for the country of installation is shipped with the Catalyst 3920.
Power | 90 to 264 VAC autosensing (single supply) |
---|---|
Frequency | 47 to 63 Hz |
AC Current Rating | 0.75A @ 115VAC, 0.38A @ 230VAC |
Thermal Dissipation | 75W max, 256 BTU/hr |
Table D-3 lists the operating environment parameters of a Catalyst 3920.
Characteristic | Value or Range |
---|---|
Operating temperature | 50° F to 104° F (10° C to 40° C) |
Operating relative humidity | 8% to 80% |
Maximum wet-bulb temperature | 81° F (27° C) |
Thermal dissipation | 150 watts (maximum); 512 Btu/hr |
Electrical power | 1.5 A at 115V; 0.75 A at 230V |
Leakage/starting | Current less than 3.5 mA/15 amperes/half cycle |
Posted: Tue Oct 12 11:53:57 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.