Table Of Contents
A.1.3 8xG.SHDSL Specifications
A.1.7 DS3+T1/E1 IMA NI-2 Card Specifications
A.1.8 DS3/2DS3 NI-2 Card Specifications
A.1.9 OC-3c/2DS3 NI-2 Card Specifications
A.1.10 OC-3c/OC-3c NI-2 Card Specifications
A.1.11 DS3/2DS3+8xT1 IMA I/O Card Specifications
A.1.12 DS3/2DS3 I/O Card Specifications
A.1.14 Blower Tray Specifications
Technical Specifications
This appendix provides the technical specifications for the Cisco 6160 system. The appendix contains the following sections:
A.1 Hardware Specifications
This section details the specifications for the following hardware components:
•Cisco 6160 system
•Octal-port ITU-C line card (8xIDSL)
•Octal-port G.SHDSL SHTU-C line card (8xG.SHDSL)
•Octal-port DMT ATU-C line card (8xDMT)
•Quad-port STU-C line card (4xSDSL)
•Quad-port flexi ATU-C line card (4xflexi)
•DS3+T1/E1 IMA NI-2 card
•DS3/2DS3 NI-2 card
•OC-3c/2DS3 NI-2 card
•OC-3c/OC-3c NI-2 card
•DS2/2DS3+8xT1 IMA I/O card
•DS3/2DS3 I/O card
•Power entry module (PEM)
•Blower tray
A.1.1 Cisco 6160 System
Table A-1 lists the hardware specifications for the Cisco 6160 system.
Table A-1 Cisco 6160 System Hardware Specifications
Specification DescriptionCisco 6160 chassis dimensions
11 RUs1 —18.35 in. x 21.352 in. x 11.8 in. (46.6 cm x 54.2 cm x 30.0 cm)
Cisco 6160 chassis weight
Empty—Approximately 40 lb (18.2 kg)
Loaded—Approximately 95 lb (43.2 kg)
Acoustic noise
60 dB at normal fan speed
Network interface
• OC-3c (single- or multimode fiber) WAN uplink or subtend
•DS3 WAN uplink or subtend
•T1 WAN uplink or subtend
•T1 IMA group WAN uplink or subtend
ADSL Interface
CAP—Up to 7.168 Mbps downstream/1.088 Mbps upstream
DMT—Up to 8.032 Mbps downstream/864 kbps upstream
G.lite—Up to 1.536 Mbps downstream/512 kbps upstream
SDSL Interface
2B1Q up to 1168 kbps upstream and downstream
SHDSL Interface
TC-PAM up to 2312 kbps upstream and downstream
IDSL Interface
2B1Q
Craft interface
Console terminal connection on the NI-2 card
Management access
•RJ-45 interface for craft alarm discovery
•RJ-45 Ethernet
•ATM in-band management
External alarm contacts
Single dry contact alarm input (NO)
Power requirements
Dual inputs, -48VDC each
Note See "Preparing for Installation," for detailed power requirements.
CO operating requirements
Temperature
Altitude
Humidity41 to 104єF (5 to 40єC)—Operating
23 to 122єF (-5 to 50єC)—Short-term operating
-197 to 13,124 feet (-60 to 4,000 meters)
5 to 90% (noncondensing)Subtending
NI-2 card
DS3/2DS3+8xT1 IMA I/O card
DS3/2DS3 I/O card
1 RU = rack unit. An RU is equal to 1.75 inches (4.45 cm).
2 Mounting brackets not included in width
A.1.2 8xIDSL Specifications
Table A-2 lists the specifications for the 8xIDSL.
Table A-2 8xIDSL Specifications
Specification DescriptionStandards supported
•Frame Relay FRF.8
•Frame Relay FRF.9 (compatible)
•RFC 1661/1662 (PPP over HDLC)
•RFC 1973 (PPP over Frame Relay)
•ANSI T1.601-1992
•ETSI ETR 080 (1966)
•ITU G.961
External interfaces
8 (no connectors on card)
Data rates (per port)
Downstream: Up to 144 kbps
Upstream: Up to 144 kbps
Line encoding
2B1Q
Internal hardware
•50 MHz Motorola MPC860 microprocessor
•Siemens PEF 24911/24902 (DFE/AFE)
•32 MB SDRAM
•2 MB Flash
Dimensions
Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)
Weight
0.8 lb (0.36 kg)
Power consumption
5.5W
Minimum software and network management requirement
Cisco IOS—Release 12.1(2)DA
CDM1 — Release 3.2 (optional)
1 CDM = Cisco DSL Manager
A.1.3 8xG.SHDSL Specifications
Table A-3 lists the specifications for the 8xG.SHDSL.
Table A-3 8xG.SHDSL Specifications
Specification DescriptionStandards supported
•TC-PAM without optis
•ITU G.991.2
•ITU G.994.1
•ETSI SDSL, TM6(00)10
•ETSI SDSL DRAFT (TS 101 524)
Power consumption
11.3W at 136 kbps
15.0W at 1.554 Mbps
16.5W at 2.312 Mbps
Maximum data rates (per port)
2.312 Mbps
Maximum data rate (per card)
Minimum software—Cisco IOS 12.1(7)DA2
•18.5 Mbps downstream
•5.0 Mbps for odd ports upstream
•5.0 Mbps for even ports upstream
Minimum software—Cisco IOS 12.2(7)DA
•18.5 Mbps downstream
•18.5 Mbps upstream
External interfaces
8 (no connectors on card)
Internal hardware
MPC850 3.3V power 40-Mhz CPU
Dimensions
Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)
Weight
0.70 lb (0.32 kg)
Minimum software and network management requirement
Cisco IOS—Release 12.1(7)DA2
CDM—Release 3.3(3) (optional)
Minimum software and network management requirement for RADSL1
Cisco IOS—Release 12.2(7)DA
CDM—Release 3.4 (optional)
1 RADSL = rate adaptive digital subscriber line
A.1.4 8xDMT Specifications
Table A-4 lists the specifications for the 8xDMT.
A.1.5 4xSDSL Specifications
Table A-5 lists the specifications for the 4xSDSL.
A.1.6 4xflexi Specifications
Table A-6 lists the specifications for the 4xflexi.
A.1.7 DS3+T1/E1 IMA NI-2 Card Specifications
Table A-7 lists the physical and electrical specifications of the DS3+T1/E1 IMA NI-2 card.
Table A-7 DS3+T1/E1 IMA NI-2 Card Specifications
Specification DescriptionInternal hardware
•150 MHz RC64475 CPU
•Galileo GT64120 system controller
•1M x 32 boot flash
•4M x 32 Flash
•512 KB boot EPROM
Dimensions
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
Weight
3.0 lb (1.36 kg)
External interfaces1
One DS3 (44.736 Mbps) coaxial port
Eight T1(1.544 Mbps)/E1 (2.048 Mbps) RJ-48 ports
Connector types2
DS3—BNC
E1/T1—RJ-48
Impedance
DS3—75 ohms (nominal)
T1—100 ohms (nominal)
E1—120 ohms (nominal)
Line encoding
DS3—B3ZS
T1—AMI or B8ZS
E1—AMI or HDB3
Framing
DS3—C-bit parity, optionally PLCP with M23, otherwise ADM3
T1—SF or ESF
E1—PCM30 or CRC4
Transmission distance
DS3—Short haul: <225 feet (68.58 meters), long haul: 225 to 450 feet (68.58 to 137.16 meters)
T1/E1—Short haul: 0 to 655 feet (0 to 199.64 meters), long haul: >655 feet (199.64 meters) no span power
Power consumption
32.5W
Minimum software and network management requirement
Cisco IOS
•Non-redundant NI-2 card configurations—Release 12.1(6)DA
•Redundant NI-2 card configurations—Release 12.1(7)DA
CDM—Release 3.3(2) (optional)
1 All external interfaces for the DS3+T1/E1 IMA NI-2 card are located on the I/O card.
2 All trunk and subtend connectors for the DS3+T1/E1 IMA NI-2 card are located on the I/O card.
3 ADM = add/drop multiplexer.
A.1.8 DS3/2DS3 NI-2 Card Specifications
Table A-8 lists the specifications of the DS3/2DS3 NI-2 card.
Table A-8 DS3/2DS3 NI-2 Card Specifications
Specification DescriptionInternal hardware
•150 MHz RC64475 CPU
•Galileo GT64120 system controller
•1M x 32 boot flash
•4M x 32 Flash
•512 KB boot EPROM
Dimensions
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
Weight
3.0 lb (1.36 kg)
Layer 2 protocol
ATM
External interfaces1
Three DS3/E3 coaxial ports
Connector type2
BNC
Impedance
75 ohms (nominal)
Line encoding
B3ZS
Framing
C-bit parity, optionally PLCP with M23, otherwise ADM
Transmission distance
DS3—Short haul: <225 feet (68.58 meters), long haul: 225 to 450 feet (68.58 to 137.16 meters)
Power consumption
33.5W
Minimum software and network management requirement
Cisco IOS
•Non-redundant NI-2 card configurations—Release 12.1(1)DA
•Redundant NI-2 card configurations—Release 12.1(7)DA
CDM—Release 3.0/3.2 (optional)
1 All external interfaces for the DS3/2DS3 NI-2 card are located on the I/O card.
2 All trunk and subtend connectors for the DS3/2DS3 NI-2 card are located on the I/O card.
A.1.9 OC-3c/2DS3 NI-2 Card Specifications
Table A-9 lists the specifications of the OC-3c/2DS3 NI-2 card.
Table A-9 OC-3c/2DS3 NI-2 Card Specifications
Specification DescriptionInternal hardware
•150 MHz RC64475 CPU
•Galileo GT64120 system controller
•1M x 32 boot flash
•4M x 32 Flash
•512 KB boot EPROM
Dimensions
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
Weight
3.0 lb (1.36 kg)
Power consumption
33.5W
Layer 2 protocol
ATM
Minimum software and network management requirement
Cisco IOS
•Non-redundant NI-2 card configurations—Release 12.1(1)DA
•Redundant NI-2 card configurations—Release 12.1(7)DA
CDM—Release 3.0/3.2 (optional)
DS3 Ports (Subtending)(DS3 port specifications are the same for single-mode and multimode cards.)
External interfaces1
Two DS3 (44.736 Mbps) coaxial ports
Connector type2
BNC
Impedance
75 ohms (nominal)
Line encoding
B3ZS
Framing
C-bit parity, optionally PLCP with M23, otherwise ADM
OC-3c Port (Trunk) Single-Mode Card Multimode CardExternal interface
One OC-3c/STM-1 (155 Mbps) single-mode port
One OC-3c/STM-1 (155 Mbps) multimode port
Connector type
SC-PC
SC-PC
Fiber type
Intermediate reach single mode
Multimode
Average transmitted power
-15 to -8 dBm
-20 to -14 dBm
Average received power
-8 dBm
-11 dBm
Transmission distance
Up to 12 miles (19.3 km)
Up to 1.2 miles (1.93 km)
Wavelength
1310 nm
1300 nm
1 The DS3 subtending interfaces for the OC-3c/2DS3 NI-2 card are located on the I/O card.
2 The BNC subtend connectors for the OC-3c/2DS3 NI-2 card are located on the I/O card.
A.1.10 OC-3c/OC-3c NI-2 Card Specifications
Table A-10 lists the specifications of the single-mode and multimode versions of the OC-3c/OC-3c NI-2 card.
Table A-10 OC-3c/OC-3c NI-2 Card Specifications
Specification DescriptionInternal hardware
•150 MHz RC64475 CPU
•Galileo GT64120 system controller
•1M x 32 boot flash1 (4 MB)
•4M x 32 Flash (16 MB)
•512 KB boot EPROM
Dimensions
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
Weight
3.0 lb (1.36 kg)
Layer 2 protocol
ATM
Power consumption
33.5W
Minimum software and network management requirement
Cisco IOS
•Non-redundant NI-2 card configurations—Release 12.1(1)DA
•Redundant NI-2 card configurations—Release 12.1(7)DA
CDM—Release 3.0/3.2 (optional)
Single-Mode Card Multimode CardExternal interfaces
Two OC-3c/STM-1 (155 Mbps) single-mode ports
Two OC-3c/STM-1 (155 Mbps) multimode ports
Connector type
SC-PC
SC-PC
Fiber type
Intermediate reach single mode
Multimode
Average transmitted power
-15 to -8 dBm
-20 to -14 dBm
Average received power
-8 dBm
-11 dBm
Transmission distance
Up to 12 miles (19.3 km)
Up to 1.2 miles (1.93 km)
Wavelength
1310 nm
1300 nm
1 The version of the OC-3c/OC-3c NI-2 card with enhanced upstream bandwidth features (NI2-155SM-155SM2 and NI2-155MM-155MM2) has a 2M x 32 bootflash (8 MB).
A.1.11 DS3/2DS3+8xT1 IMA I/O Card Specifications
Table A-11 lists the specifications of the DS3/2DS3+8xT1 IMA I/O card.
A.1.12 DS3/2DS3 I/O Card Specifications
Table A-12 lists the specifications of the DS3/2DS3 I/O card.
A.1.13 PEM Specifications
Table A-13 lists the specifications of the PEM.
A.1.14 Blower Tray Specifications
Table A-14 lists the specifications of the blower tray.
A.2 Software Specifications
Table A-15 lists Cisco 6160 system software specifications.
Table A-15 Software Specifications
Specification DescriptionManagement protocols
Software support for SNMP to Cisco EMF1
Management applications
•Cisco IOS
•CDM
Management interfaces
In band—ATM VC
Out of band—10BaseT Ethernet, console, auxiliary
1 EMF = Element Management Framework
Posted: Thu Feb 24 12:55:45 PST 2005
All contents are Copyright © 1992--2005 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.