Upgrading MCI Cards from Microcode Versions 1.5, 1.7, 1.8, 1.9, and 1.10 to Microcode Versions 1.11 or 1.11A
Determining System Compatibility
Preventing Electrostatic Discharge Damage
Opening the Chassis
Replacing the Components
Cisco Information Online

Upgrading MCI Cards from Microcode Versions 1.5, 1.7, 1.8, 1.9, and 1.10 to Microcode Versions 1.11 or 1.11A


Product Numbers: MC-MCI-V1.11= and MC-MCI-V1.11A=

This document describes how to upgrade the microcode on Revision 2 and Revision 3 multiport communications interface (MCI) cards from Microcode Versions 1.5, 1.7, 1.8, 1.9/1.9A, or 1.10/1.10A to Microcode Version 1.11/1.11A.

For the MCI microcode upgrades, the following statements apply to both card types:

Determining System Compatibility

You can determine the MCI card type (1.0 or 1.1) and its current microcode version in two ways: either inspect the card or display the information using the EXEC command show controller mci.

To inspect the card, first remove it from the card cage. Examine the silkscreened label along the right side of the card: the cards are marked Rev./3 for the card type 1.1, and Rev./2 for the card type 1.0. Examine the microcode EPROMs to determine the microcode version.

To display the type and current microcode version on the screen, enter the EXEC command show controller mci. When an MCI Rev./ 3 (controller type 1.1) card is installed, the first line of the display for each installed MCI card (MCI 0, MCI 1, and so on) should be as follows:

MCI 0, controller type 1.1, microcode version 1.10

When an MCI Revision 2 (Controller Type 1.0) card is installed, the first line of the display for each installed MCI card (MCI 0, MCI 1, and so on) should be as follows:

MCI 0, controller type 1.0, microcode version 1.10

Verify that the microcode version is at least 1.5 or 1.10. If it is not, contact a customer service representative for information on microcode upgrades for the Type 1.0 MCI card.

Preventing Electrostatic Discharge Damage

Electrostatic discharge damage (ESD) occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. ESD can impair electronic circuitry and equipment. Always follow ESD prevention procedures when removing and replacing cards. Following are steps for handling printed circuit cards:


Step 1   Slip on an ESD-preventive wrist strap, ensuring that it makes good skin contact.

Step 2   Connect the strap to an unpainted chassis frame surface or another proper grounding point or surface to safely channel unwanted ESD voltages to ground.

Step 3   Use the ejector levers to remove the card. Handle the card by its edges. Place the card on an antistatic surface or in a static shielding bag. To prevent further damage to the card by ESD voltages, defective cards must remain in the static shielding bag when returned for repair or replacement.

Step 4   Handling the new card by its edges only, insert it into the chassis. Avoid contact between the card and clothing. The wrist strap only protects the card from ESD voltages on the body; ESD voltages on clothing can still damage the card.


Caution

For safety, periodically use an ohmmeter to check the ESD-preventive wrist strap to ensure that the resistor is providing proper ESD protection. The measurement should be between 1 and 10 megohms.


Opening the Chassis

Remove the front access panel to access the cards in the card cage and remove the top cover to access the other chassis components. The following procedures include instructions for both. Use the appropriate procedure for your chassis type.

Tools Required

You will need the following tools to access the chassis interior:

A-Type Chassis Access Procedure

Following is the procedure for accessing the A-type chassis interior.


Warning
Before accessing the chassis interior, turn off power to the chassis and unplug the power cord because hazardous voltages may exist in or near the power supply. Use extreme caution when working near the power supply.


Step 1   Turn OFF power to the chassis, and unplug it from AC power.

Step 2   If the chassis is rack mounted, disconnect all external cables from the chassis rear panel. Note where these cables were connected, for reinstallation.

Step 3   Remove the chassis from the rack and transfer it to a desktop or worktable.

Step 4   If you will need to handle any electronic components (cards, and so forth), attach appropriate ESD protection and attach the AC power cord but, to prevent a shock hazard, make certain the chassis power is OFF.

Step 5   To access cards in the card cage, loosen the two thumbscrews on the front access panel and remove the panel from the chassis. (See Figure 1.) If you need to access cards in the card cage only, omit the next step.

Step 6   To access other system components, locate and remove the seven number 1 Phillips screws securing the top cover. (See Figure 1.) Remove the top cover, and set it and the screws aside.


Note      Newer chassis have more screws than shown in Figure 1. There may be 5 thumbscrews and 14 cover screws.



Figure 1   Chassis Front and Top Panels



Note      To reassemble the chassis, reverse all steps.


MGS Chassis Access Procedure

Following is the procedure for accessing the MGS chassis interior.


Warning

Before accessing the chassis interior, turn off power to the chassis and unplug the power cord because hazardous voltages may exist in or near the power supply. Use extreme caution when working near the power supply.



Step 1   Turn OFF power to the chassis and unplug it from AC power.

Step 2   If the chassis is rack mounted, disconnect all external cables from the chassis rear panel. Note where these cables were connected, for reinstallation.

Step 3   Remove the chassis from the rack and transfer it to a desktop or worktable.

Step 4   If you need to handle any electronic components (cards, and so forth), attach appropriate ESD protection and attach the AC power cord but, to prevent a shock hazard, make certain the chassis power is OFF.

Step 5   To access the cards in the card cage, locate the three flat-blade screws that secure the card cage access panel. (See Figure 2.) These screws are located on the top of the MGS chassis access panel.

Step 6   Using the flat-blade screwdriver, turn each of these screws 1/4 to 1/2 turn counterclockwise until the screw pops up.

Step 7   Using the number 2 Phillips screwdriver, loosen the three screws at the bottom edge of the card cage cover. (Do not remove these screws completely.) Carefully remove the card cage cover and set it aside.

Step 8   To access the other chassis components, use the number 1 Phillips screwdriver to remove the 14 screws that secure the top cover of the MGS chassis. (See Figure 2.) Remove the top cover and set it aside.


Figure 2   Screw Locations on the MGS Chassis Exterior—Side View



Note      To reassemble the chassis, reverse all steps.


C Chassis Access Procedure

Following is the procedure for accessing the C chassis interior.


Warning

Before accessing the chassis interior, turn off power to the chassis and unplug the power cord because hazardous voltages may exist in or near the power supply. Use extreme caution when working near the power supply.



Step 1   Turn OFF power to the chassis and unplug it from AC power.

Step 2   If you need to handle any electronic components (cards, and so forth), attach appropriate ESD protection and attach the AC power cord but, to prevent a shock hazard, make certain the chassis power is OFF.

Step 3   Turn the chassis over so that the bottom is facing up. Use the number 2 Phillips screwdriver to remove the ten screws that secure the cover of the C chassis. There are two screws on each side and six screws on the bottom of the chassis. (See Figure 3.)


Figure 3   Screw Locations on the C Chassis Exterior—Side View


Step 4   Turn the chassis back over and position it so that the back (the side with the ports) is on your left and the front of the chassis (with the LED) is on your right. (This is completely opposite of the chassis position shown in Figure 3.)

Step 5   While holding the back of the chassis with your left hand, pull the front of the cover to the right until the power supply and card cage are completely exposed. Because the fit is snug, pull slowly and carefully, and do not remove the cover.


Caution
Several cables are located close to the interior of the C chassis cover. Avoid damage to these cables by ensuring that they do not impede the cover as you slide it.


Note      To reassemble the chassis, reverse all steps.


Replacing the Components

To replace the MCI cards, you need some or all of the following:


Caution

To prevent ESD damage, refer to the section "Preventing Electrostatic Discharge Damage."


The following procedure is for upgrading both MCI type 1.0 and 1.1 cards. The microcode components are in the same locations on both cards; however, the socket numbers are different. Illustrations and tables indicating the correct socket designations are provided for each card. Ensure that you are referring to the correct illustration and table when placing the components in the sockets.


Step 1   Turn OFF power to the system but, to channel ESD voltages to ground, do not disconnect the power cord.

Step 2   Open the chassis using one of the procedures in the section "Opening the Chassis."

Step 3   Put on the ESD-preventive wrist strap provided with the upgrade kit, or use your own grounding strap. Attach the equipment end of the strap to an unpainted area on the chassis.

Step 4   Disconnect the internal ribbon cables that are attached to the front of the MCI card. If other cables (to other cards) are in front of the MCI card and prevent you from removing it, note the card and port locations of each before disconnecting them (to avoid misrouting cables when you reinstall the card).

Step 5   Use your thumbs to pull the ejector levers out and away from the card edge to loosen it; then pull the card out of its slot. Place the card on an antistatic mat.

Step 6   Locate the 16 components to be replaced (14 on cards with Ethernet only).

Step 7   Remove each of the old components with the chip extractor. If one is not available, use a flat-blade screwdriver to gently pry each component out of its socket.

Step 8   Insert the new components into the appropriate sockets, as follows:


Figure 4   MCI Controller Type 1.0—Component-Side View


Table 1   MCI Controller Type 1.0 Components

Socket  Version 1.5  Version 1.7   Version 1.8  Version 1.9 or 1.9A  Version 1.10   Version 1.11 

B1

17-0472

17-0751

17-0751B

17-0751-01

17-0751-02 U19

17-0751-04 U191

B2

17-0473

17-0752

17-0752(A)2

17-0752-01

17-0752-02 U18

17-0752-04 U18

B3

17-0474

17-0753

17-0753B

17-0753-01

17-0753-02 U33

17-0753-04 U33

B4

17-0475

17-0754

17-0754(A)

17-0754-01

17-0754-02 U34

17-0754-04 U34

B5

17-0476

17-0755

17-0755(A)

17-0755-01

17-0755-02 U35

17-0755-04 U35

B6

17-0477

17-0756

17-0756(A)

17-0756-01

17-0756-02 U36

17-0756-04 U36

B7

17-0478

17-0757

17-0757(A)

17-0757-01

17-0757-02 U37

17-0757-04 U37

B8

17-0479

17-0758

17-0758(A)

17-0758-01

17-0758-02 U38

17-0758-04 U38

B9

17-0480

17-0759

17-0759(A)

17-0759-01

17-0759-02 U39

17-0759-04 U39

B10

17-0481

17-0760

17-0760(A)

17-0760-01

17-0760-02 U310

17-0760-04 U310

B11

17-0482

17-0761

17-0761(A)

17-0761-01

17-0761-02 U311

17-0761-04 U311

B12

17-0484

17-0764

17-0764B

17-0764-01

17-0762-02 U312

17-2005-01 U3123

B13

17-0485 or 13/132A

17-0763

17-0763(A)

17-0763-01

17-0763-02 U313

17-0763-04 U313

F5

17-0038 or 13/107A

17-0675

17-0675

17-0675

17-0675

17-06754

M1

R68561P

R68561AP-01

R68561AP-01

R68561AP-01

R68561AP-01

R68561AP-015

M2

R68561P

R68561AP-01

R68561AP-01

R68561AP-01

R68561AP-01

R68561AP-015

The new component number contains a six-digit part number, a two-digit version identifier, and a socket location number. For example, the component number "17-0751-04 U19" contains part number 17-0751, version identifier 04, which corresponds to MCI Microcode Version 1.11 or 1.11A, and socket number U19 (or B1 for the Type 1.0 MCI card).

The A designator (shown in parentheses) appears on the Version 1.8 part numbers only if you received the complete Version 1.8 kit (which included the part number appended with B). If you received the partial Version 1.8 kit, it contained only the three parts appended with B.

This 17-2005-01 component is unique to the 1.11 and 1.11A microcode upgrades for the MCI type 1.0 card. Note that 17-2005-01 is functionally equivalent to component 17-0762-05 in the version 1.11A kit.

The 17-0675 bus-timing PAL is required only if you have upgraded from a CSC/2 to a CSC/3 or CSC/4 processor, along with this MCI microcode upgrade. If your system used a CSC/3 or CSC/4 before the MCI microcode upgrade, the 17-0675 PAL component is not required; you will have some PAL components left over after all microcode components are installed.

These Rockwell components are used only on cards with serial interfaces, and then only for the MC-MCI-1.11 upgrade. The MC-MCI-V1.11A upgrade does not require these Rockwell components.


Figure 5   MCI Controller Type 1.1—Component-Side View


Table 2   MCI Controller Type 1.1 Components

Socket   Version 1.7   Version 1.8  Version 1.9 and 1.9A  Version 1.10A  Version 1.11A 

U19

17-0751

17-0751B

17-0751-01 U19

17-0751-02 U19

17-0751-04 U191

U18

17-0752

17-0752(A)2

17-0752-01 U18

17-0752-02 U18

17-0752-04 U18

U33

17-0753

17-0753B

17-0753-01 U33

17-0753-02 U33

17-0753-04 U33

U34

17-0754

17-0754(A)

17-0754-01 U34

17-0754-02 U34

17-0754-04 U34

U35

17-0755

17-0755(A)

17-0755-01 U35

17-0755-02 U35

17-0755-04 U35

U36

17-0756

17-0756(A)

17-0756-01 U36

17-0756-02 U36

17-0756-04 U36

U37

17-0757

17-0757(A)

17-0757-01 U37

17-0757-02 U37

17-0757-04 U37

U38

17-0758

17-0758(A)

17-0758-01 U38

17-0758-02 U38

17-0758-04 U38

U39

17-0759

17-0759(A)

17-0759-01 U39

17-0759-02 U39

17-0759-04 U39

U310

17-0760

17-0760(A)

17-0760-01 U310

17-0760-02 U310

17-0760-04 U310

U311

17-0761

17-0761(A)

17-0761-01 U311

17-0761-02 U311

17-0761-04 U311

U312

17-0762

17-0762B

17-0762-01 U312

17-0762-03 U312

17-0762-05 U312

U313

17-0763

17-0763(A)

17-0763-01 U313

17-0763-02 U313

17-0763-04 U313

U112

17-0675

17-0675

17-0675

-

-

U73

R68561AP-01

R68561AP-01

R68561AP-01

-

-

U74

R68561AP-01

R68561AP-01

R68561AP-01

-

-

The new component number contains a six-digit part number, a two-digit version identifier, and a socket location number. For example, the component number "17-0751-04 U19" contains part number 17-0751, version identifier 04, which corresponds to MCI Microcode Version 1.11 or 1.11A, and socket number U19.

The A designator (shown in parentheses) appears on the Version 1.8 part numbers only if you received the complete Version 1.8 kit (which included the part number appended with B). If you received the partial Version 1.8 kit, it contained only the three parts appended with B.


Caution
Be careful not to bend or crush any of the pins when inserting the new components. If any pins become bent, use needlenose pliers to straighten the pins; then carefully reinsert the component. If a component is installed backwards when power is turned ON, the component will be damaged. Contact a customer service representative to obtain a replacement.

Step 9   When all of the components are replaced, reinsert the card, reconnect the internal cables, replace the access panel, and restart the system.

Step 10   Enter the EXEC command show controller mci. The first line of the display for each installed MCI card should be as follows:

MCI 0, controller type 1.n, microcode version 1.11 (where n is 1 or 0)

Step 11   Use the display from the show controller mci command to verify that the microcode version is 1.11.

This completes the microcode upgrade procedure.

Cisco Information Online

Cisco Information Online (CIO) is Cisco Systems' primary, real-time support channel. You can use your product serial number to activate CIO for a single user during your warranty period. Maintenance customers and partners can self-register on CIO to obtain additional content and services.

Available 24 hours a day, 7 days a week, CIO provides a wealth of standard and value-added services to Cisco's customers and business partners. CIO services include product information, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CIO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously—a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CIO (called "CIO Classic") supports Zmodem, Kermit, Xmodem, FTP, Internet e-mail, and fax download options, and is excellent for quick access to information over lower bandwidths. The WWW version of CIO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CIO in the following ways:

For a copy of CIO's Frequently Asked Questions (FAQ), contact  cio-help@cisco.com. For additional information, contact  cio-team@cisco.com.


Note      If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.



hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Nov 6 16:05:47 PST 2003
All contents are Copyright © 1992--2003 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.