Country Code/ Country
|
1000 Series Access Point Regulatory Domain
|
802.11 Bands
|
Channels Allowed
|
Maximum Transmit Power (Radio Tx + Antenna Gain = EIRP)
|
Indoor/ Outdoor Use
|
Frequency Range (GHz)
|
Regulatory Authority
|
AT/ Austria
|
-E
|
a
|
36, 40, 44, 48
|
60 mW EIRP
|
In
|
5.15-5.25
|
BMV/ FSB-LD047
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
AU/ Australia
|
-N
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.725-5.825
|
ACA
|
b
|
1 - 11
|
200 mW EIRP
|
Both
|
2.4-2.4835
|
BE/ Belgium
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
120 mW EIRP 120 mW EIRP
|
In In
|
5.15-5.25
|
BIPT/ Annexe B3 Interface radio HIPERLAN
|
b/g
|
1 - 12 13
|
100 mW EIRP 100 mW EIRP
|
In Out
|
2.4-2.4835
|
BR/ Brazil
|
-C
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
200 mW EIRP
1 W EIRP
|
In
Both
|
5.725-5.85
|
Anatel/ Resolution 305
|
b/g
|
1 - 11
|
1 W EIRP
|
Both
|
2.4-2.4835
|
CA/ Canada
|
-A
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
Industry Canada RSS-210
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
CH/ Switzerland and Liechtenstein
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP 200 mW EIRP
|
In In
|
5.15-5.25 5.25-5.35
|
OFCOM
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
CN/ China
|
-C
|
a
|
149, 153, 157, 161
|
150 mW+6 dBi~600 mW
|
Both
|
5.725-5.825
|
RRL/ MIC Notice 2003-13
|
b/g
|
1-13
|
150 mW+6 dBi~600 mW
|
Both
|
2.4-2.4835
|
CY/ Cyprus
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
(tbd)
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
CZ/ Czech Republic
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.725-5.825
|
CTO
|
b
|
1 - 11
|
200 mW EIRP
|
Both
|
2.4-2.4835
|
DE/ Germany
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
RegTP/ wlan35
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
DK/ Denmark
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
ITST/ Radio interface specification 00 007
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
EE/ Estonia
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
SIDEAMET
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
ES/ Spain
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
Ministry of Telecom
|
b/g
|
1 - 11
|
100 mW EIRP
|
In
|
2.412-2.472
|
FI/ Finland
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
FICORA/ RLAN Notice
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
FR/ France
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP 200 mW EIRP
|
In In
|
5.15-5.25 5.25-5.35
|
A.R.T./ Decision 01-441
|
b/g
|
1 - 7 8 - 11
|
100 mW EIRP 100 mW EIRP
|
Both In
|
2.4-2.4835 2.4-2.454
|
GB/ United Kingdom
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
UKRA/ IR2006
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
GR/ Greece
|
-E
|
b/g
|
1 - 11
|
100 mW EIRP
|
In
|
2.4-2.4835
|
Ministry of Transport & Comm.
|
HK/ Hong Kong
|
-N
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
200 mW EIRP 200 mW EIRP 1 W+6 dBi=4 W
|
Both Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
OFTA
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
HU/ Hungary
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP
|
In
|
5.15-5.25 5.25-5.35
|
HIF
|
b/g
|
1 - 11
|
1 W EIRP
|
Both
|
2.4-2.4835
|
ID/ Indonesia
|
-R
|
a
|
N/A
|
N/A
|
N/A
|
5.725-5.875
|
PDT
|
b/g
|
1-13
|
100 mW EIRP
|
In
|
2.4-2.5
|
IE/ Ireland
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
COMREG/ ODTR 00/61, ODTR 0062
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
IL/ Israel
|
-I
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP 200 mW EIRP
|
In In
|
5.15-5.25 5.25-5.35
|
MOC
|
b/g
|
1 - 13
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
ILO/ Israel OUTDOOR
|
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
200 mW EIRP 200 mW EIRP
|
In In
|
5.15-5.25 5.25-5.35
|
MOC
|
b/g
|
5 - 13
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
IN/ India
|
(TBD)
|
a
|
N/A
|
N/A
|
N/A
|
N/A
|
WPC
|
b/g
|
|
4 W EIRP
|
In
|
2.4-2.4835
|
IS/ Iceland
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
PTA
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
IT/ Italy
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
Ministry of Comm
|
b/g
|
1 - 11
|
100 mW EIRP
|
In
|
2.4-2.4835
|
JP/ Japan
|
-J
|
a
|
1-3 1-4
|
100 mW EIRP 100 mW EIRP
|
Both In
|
5.03-5.09 5.15-5.25
|
Telec/ARIB STD-T66
|
b
|
1-14
|
10 mW/MHz~200mW EIRP
|
Both
|
2.4-2.497
|
g
|
1-13
|
10 mW/MHz~200mW EIRP
|
Both
|
2.4-2.497
|
KR/ Republic of Korea
|
-C
|
a
|
149, 153, 157, 161
|
150 mW+6 dBi~600 mW
|
Both
|
5.725-5.825
|
RRL/ MIC Notice 2003-13
|
b/g
|
1-13
|
150 mW+6 dBi~600 mW
|
Both
|
2.4-2.4835
|
LT/ Lithuania
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
LTR
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
LU/ Luxembourg
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
ILR
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
LV/ Latvia
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
(tbd)
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
MY/ Malaysia
|
-E
|
b/g
|
1-13
|
100 mW EIRP
|
In
|
2.4-2.5
|
CMC
|
NL/ Netherlands
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
Radiocom Agency
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
NO/ Norway
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
NPT
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
NZ/ New Zealand
|
-N
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
RSM
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
PH/ Philippines
|
-C
|
a
|
(tbd)
|
(tbd)
|
(tbd)
|
5.725-5.875
|
PDC
|
b
|
(tbd)
|
100 mW EIRP
|
(tbd)
|
2.4-2.4835
|
PL/ Poland
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
200 mW EIRP
1 W EIRP
|
In
Both
|
2.4-2.4835
|
Office of Telecom & Post
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
PT/ Portugal
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
NCA
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
SE/ Sweden
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 104, 108, 112, 116, 120, 124, 128, 132, 140
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
In In Both
|
5.15-5.25 5.25-5.35 5.47-5.725
|
PTS
|
b/g
|
1 - 11
|
100 mW EIRP
|
Both
|
2.4-2.4835
|
SG/ Singapore
|
-S
|
a
|
36, 40, 44, 48, 52, 56, 60, 64, 149, 153, 157, 161
|
200 mW EIRP 200 mW EIRP 1 W EIRP
|
Both Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
IDA/ TS SSS Issue 1
|
b/g
|
1 - 13
|
200 mW EIRP
|
Both
|
2.4-2.4835
|
SI/ Slovenia
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
ATRP
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
SK/ Slovak Republic
|
-E
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
Telecom Admin.
|
b/g
|
1 - 11
|
1 W+Restricted Antennas
|
Both
|
2.4-2.4835
|
TH/ Thailand
|
-R
|
a
|
N/A
|
N/A
|
N/A
|
5.725-5.875
|
PDT
|
b/g
|
1-13
|
100 mW EIRP
|
In
|
2.4-2.5
|
TW/ Taiwan
|
-T
|
a
|
56, 60, 64, 100 - 140 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both
|
5.25-5.35 5.47-5.725 5.725-5.825
|
PDT
|
b/g
|
1-13
|
1 W EIRP
|
Both
|
2.4-2.4835
|
US/ United States of America
|
-A
|
a
|
36, 40, 44, 48 52, 56, 60, 64 149, 153, 157, 161
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W 1 W+6 dBi=4 W
|
In Both Both
|
5.15-5.25 5.25-5.35 5.725-5.85
|
FCC Part 15
|
b/g
|
1 - 11
|
1 W Conducted Output
|
Both
|
2.4-2.4835
|
USE/ United States of America
|
-A
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W
|
In Both
|
5.15-5.25 5.25-5.35
|
FCC Part 15
|
b/g
|
1 - 11
|
1 W Conducted Output
|
Both
|
2.4-2.4835
|
USL/ United States of America LOW
|
-A
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W
|
In Both
|
5.15-5.25 5.25-5.35
|
FCC Part 15
|
b/g
|
1 - 11
|
1 W Conducted Output
|
Both
|
2.4-2.4835
|
USX/ United States of America EXTENDED
|
(TBD)
|
a
|
36, 40, 44, 48 52, 56, 60, 64
|
50 mW+6 dBi=200 mW 250 mW+6 dBi=1 W
|
In Both
|
5.15-5.25 5.25-5.35
|
FCC Part 15
|
b/g
|
1 - 11
|
1 W Conducted Output
|
Both
|
2.4-2.4835
|
ZA/ South Africa
|
(TBD)
|
a
|
N/A
|
N/A
|
N/A
|
5.25-5.35 5.725-5.825
|
(tbd)
|
b/g
|
1-13
|
1 W EIRP
|
Both
|
2.4-2.4835
|