This appendix provides the technical specifications for the Cisco CTE 1400. Power, physical, and environmental specification are listed in Table A-1.
Table A-1: Technical Specifications
Power1
|
AC power supply:
|
|
- Wattage
| 125W
|
- Voltage
| 100 to 240 VAC, 3.6-1.8 A, 60 to 50 Hz
|
- System battery
| CR2032 3-V lithium coin cell
|
1 Under typical line conditions and over the entire system ambient operating range, the inrush may read 45 A per installed power supply.
|
Physical
|
Rack Mount (1U):
|
|
- Height
| 1.7 inches (4.3 cm)
|
- Width
| 16.7 inches (42.5 cm)
|
- Depth
| 22 inches (55 cm)
|
- Weight
| 23 lb (10 kg) maximum
|
Environmental
|
Temperature:
|
|
- Operating
| 50 to 95°F (10 to 35°C)
|
- Storage
| -40 to 149°F (-40 to 65°C)
|
Relative humidity:
|
|
- Operating
| 8 to 80% (noncondensing) with a humidity gradation of 10% per hour
|
- Storage
| 5 to 95% (noncondensing)
|
Maximum vibration:
|
|
- Operating
| 0.25 G (half-sine wave) at a sweep of 3 to 200 Hz for 15 minutes
|
- Storage
| 0.5 G at 3 to 200 Hz for 15 minutes
|
Maximum shock:
|
|
- Operating
| Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 41 G for up to 2 ms
|
- Storage (non-operational)
| Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for 2 ms
|
Altitude:
|
|
- Operating
| -50 to 6,500 ft (-16 to 2000 m)
|
- Storage
| -50 to 35,000 ft (-16 to 10,600 m)
|
NOTE: For the full name of an abbreviation or acronym used in this table, see the glossary.
|