January, 2001
Obtaining Technical Assistance
This document describes the Cisco MGX 8260 software version R01.02.01.
This release has the following new features and commands.
This release incluces the following new features:
These include feature operation and support of E1 for the EMEA market.
The following new commands are introduced.
stopdisk option (0..1)
This command inhibits access to the hard disk. Since the disk enters the power-cycle, you need to cycle the power off then back on to activate the IDE. Alternatively, unplug the SCC cards and plug them back in. This command is required before Power Reset.
ping IP_Address numPkg (>=1, default: 1) option (default: 0)
This command tests connectivity to a remote host.
Examples:
ping 172.17.38.168
ping 172.17.38.168 2
ping 172.17.38.168 2 200
lstrace (no parameters)
This command shows the most recent exception information and the CPU usage, before reboot.
lsprofiler (no parameter)
This command shows the current CPU usage for the last 1 minute for all the tasks executing on the card.
This section describe the software upgrade paths and security key requirements for software upgrade.
The following section describes the upgrade path and requirements.
R01.02.01 S/W supports graceful upgrade from R01.02.00, R01.01.03 and R01.01.04.
Boot flash update is required for all upgrades.
After upgrading to R01.02.01, the security key is required to download (tftp) fw and bootflash images.
Note When upgrading software from earlier releases (R01.02.00 or earlier), the security key code is not required. |
Use the following tftp commands to download SCC software:
tftp> put vxWorks_disk.scc.fw scc.fw.[key]
tftp> put vxWorks_boot.scc.fw scc_r01.02.01.fls.[key]
Note To determine the security key code, use the dspkey command. |
Use the following tftp commands to download BSC software:
tftp> put vxWorks_dnld.bsc.fw bsc.fw[key]
tftp> put vxWorks_boot.bsc.fw bsc_r01.02.01.fls.[key]
Use the following tftp commands to download NSC software:
tftp> put vxWorks_dnld.nsc.fw nsc.fw[key]
tftp> put vxWorks_boot.nsc.fw nsc_r01.02.01.fls.[key]
You do not need to clear the configuration database for this upgrade.
This section describes the open and closed caveats. It also lists those caveats that represent feature enhancements.
The following caveats are open in this release.
DDTS Number | Caveat Description | Impact | Workaround |
---|---|---|---|
CSCdt00079 | When 325 connections are established per ENET port the system become unstable | System unstable | Use 4 ENET for network access and keep the maximum number of simultaneous connection to less than 1000 |
CSCds27723 | Use of DiaMain to initialize NSC and SCC Backcards | None. Only on initial installation of the MGX8260 in manufacturing | Use DiaMain to set the initial configuration for the SCC and NSC Backcards to be recognized. |
CSCds60659 | End points stuck after 40 Calls/sec with 10% COT run in 2 hrs | After 2 hours run at 40 calls/sec and 10% COT, endpoints are stuck. No new calls can be made until the endpoint are forced to clear. Other than COT, normal system behavior and calls are not impacted. | None |
CSCds68955 | COT fails at 4 COT per second after two hours (at 40 cps) | After two hours, the solution is almost frozen. Most of the calls (and sometimes all of them) are failing. | None |
CSCds89982 | Setting 480 calls on NSC, Inconsistent speech latency within an E1 DS0 lines | Inconsistency in VoIP Speech Latency on E1 DS0s. On some E1 DS0s the latency varies widely and can be as long as 1000ms. | None |
CSCds90738 | NSC card when reset sends RAI in error | If an user adds an E1 line with "dsx1E1" framing, or reset the NSC card which has an E1 line with "dsx1E1" framing, the MGX8260 will send out an "RAI" to the Far End. This problem is due to an incorrect setup on the COMET chip. | The only way to stop sending out an "RAI" is to momentarily disconnect the cable. |
CSCdt00032 | Cells are being dropped when there is 2300 connections | Cells are being dropped slowly when there are 2300 connections with 4 ethernet line active. |
|
CSCdt00144 | MGCP - no reply to MDCX | Call will not be established for that endpoint. | None |
CSCdt00462 | SCS-reset message should reset the COT process | COT will be refused on that endpoint. Calls can still go through. | None |
CSCdr88819 | Multiple tftp connections cause task tTftp to crash | Only happens with scripts ran on NT | Use tftp on workstation. Don't run script on NT. |
CSCds14325 | BSC card to become standby but stay inBoot forever after switchover | Minimal. This only happens when Both BSC are reset at the same time. | Reset redundant BSC, one at a time |
CSCds63355 | WebViewer on 5 users | This only happen when 5 users log in at exact same time and our web server can not dispatch the resources properly when 5 users request the same pages. | The probability for this situation is small, and hardly to produce. Later on, we can use a more powerful web server to handle this problem. |
CSCds66541 | SCC switchover -- Telnet session hangs for a long time | If user login to standby SCC by telnet and SCC switchover occurs, that telnet session will takes 20 seconds to re-establish the connection. | Always telnet to the active SCC or initiate a new telnet session after the SCC switchover can avoid the long connection re-establish delay. |
CSCds67512 | Logging on WebViewer for the 1st time | Sometimes you need log in twice to get into the web viewer. | This will be solves in 1.3 and right now you just need log in web viewer at the second time after relogin and all other functions work properly. |
CSCds86081 | When active SCC failure and switchover, 'lscds' does not indicate any card failure. | None. The standby SCC take over. Trap already generated when active SCC fails. | None |
CSCds87042 | Channel 12th of every DSP sounds weird when config CODEC = G.729 | The channel cannot be used. If it is used, the voice cannot be heard clearly. | Do not use channel 12 of every DSP. |
This release introduced new features that fixed the following caveats.
.
DDTS Number | Caveat Description |
---|---|
CSCds45936 | NSUP needs to carry variable protocol version number |
CSCds59641 | Add Loop IP for call server |
CSCds60426 | RMCP does not modify the call if RCCP had all the necessary params |
CSCds66532 | When line is in LB, all channel status should be sent back as OOS |
CSCds68158 | Need iterative chds1lnecho command |
CSCds70722 | RTP Port range needs to be increased to 64K |
The following caveats are resolved in this release.
DDTS Number | Headline |
---|---|
CSCds09675 | NSCs reset due to the overflow on cell bus |
CSCds28024 | Multi-chassis: On the 64th call, MDCX reports 510 |
CSCds33557 | Autodiscovery does not discover the subchassis of *.*.*.209 |
CSCds45672 | Three SCC failed, looping on diagnostic error |
CSCds60048 | E1 timeslot allocation incorrect during call setup |
CSCds67056 | No speech path for any calls through gateway |
CSCds68054 | Re-seating SCC with power-on causes in-boot loop |
CSCds91565 | Calls are lost when SCC card physically pulled |
CSCds14725 | Unplug both IPLINKS from ACTIVE SCC isolates GW |
CSCds21055 | MGX cannot get out of Call State 5 |
CSCds34439 | Corsair responses are not sent to VSC after a VSC restart |
CSCds36891 | 8260:Addvport does not conform to E1 DS0 numbering. |
CSCds37424 | At end of unsuccessful CoT test, we sometimes see 200 RSP to DLCX |
CSCds50736 | dsx1LineStatusUpdtTrap sends 0 based slot number on BSC card |
CSCds51256 | isdnDchanDisconn traps repeatedly sent out from 172.17.38.211 |
CSCds53130 | Memory overwrriten and deallocation errors on SCC |
CSCds55698 | cardMismatchedTrap did not contain card status value |
CSCds57805 | Lines are deleted after resetnd when using SCC with NSC |
CSCds60432 | ideStop command need to be made into a CLI command. |
CSCds60941 | Count of active sonet connections goes negative |
CSCds61433 | CLI command lsds3lns failed |
CSCds64132 | Invalid Sem ID recurring often on ACT SCC |
CSCds66518 | ping crashes the chassis, when used. |
CSCds71198 | Default value for TEI must be 0 in adddlsp command |
CSCds72897 | In E1 mode, MGCP changed to IPDC and node is reset |
CSCds74709 | E1 mode, non-multiframe, max DS0 repetition limit |
CSCds78130 | MSM modules on the NSC card fails |
CSCds85023 | 8260 responds with wrong alarm on DS1 lines |
CSCdr44136 | ping command should default to a count of 5 and not infinite |
CSCdr65273 | OC3 Wander Generation does not comply with GR253 template |
CSCds05946 | Testing found calls stuck in call state 5 |
CSCds07431 | Need to update user guide regarding sw upgrades |
CSCds09650 | IPDC does not catch the error of using same RTP ports |
CSCds11067 | Both SCCs are in a never ending loop |
CSCds14378 | dbrstr does not restore node name and node number |
CSCds15655 | Need CLI to modify the system group information |
CSCds15839 | Modify FastEther line sent line modify and line active traps |
CSCds16150 | Non-descriptive trap sent when D-channel is deleted |
CSCds16316 | chipdcssadm does not accept graceful disconnect |
CSCds16389 | TEI is one-based in CLI, 0-based on the wire |
CSCds16624 | In Web viewer, we only support display trap log |
CSCds16639 | No trap sent after cold start |
CSCds16658 | Extended TCP packet w/ 28 RLSs caused IPDC link failure |
CSCds16698 | Deleting the T1 line does not clear up the bert data |
CSCds17280 | E1 lsds0s not displaying more than 24 channels. |
CSCds17652 | Download file doesn't work on the Web Viewer |
CSCds17832 | Reset NSC card sent line delete traps on non-exist lines |
CSCds17920 | DS3 performance statistics CLIs show inconsistent content |
CSCds18297 | Never use IP address 1.1.1.1 |
CSCds18759 | Trap 1320 should be info trap |
CSCds19111 | Update Web viewer for r1.2 document |
CSCds19390 | clrcdcnf on Active SCC may potentially lose trapReg DB info |
CSCds20685 | DBM NSC Card Upgrade/Downgrade Conversion Support |
CSCds22227 | Validate COMET device ID |
CSCds22292 | Squelch DS1 ALOS to prevent the debounce when the line is disconnect |
CSCds22377 | Response to RSIP is not 200 GW does not retry. |
CSCds24254 | Got major event, invokePeerRebuildTables Fail, when NSC switchover |
CSCds25226 | C:/IMAGE/SCC files are not synchronized between SCCs |
CSCds26373 | default ifType on NSC card is 0 instead of T1 (1) |
CSCds27861 | D-Channel reports extra Disc trap periodically |
CSCds27893 | Default values for some of E1 alarm thresholds are wrong in mibs |
CSCds31054 | RMG does not return connId in AddChanAck/DelChanAck when they fail |
CSCds34294 | RX underrun problem in AAL1 when multiple connections are setup |
CSCds34642 | Improvement in SAR to prevent deadlock among tasks using SAR buffer |
CSCds35443 | Need to set Spare bits in NFAS to 1s as default to comply with TBR4 |
CSCds35605 | Empty intgr line alrm on chassis |
CSCds37664 | rmDspEpGetNext always returns the same dsp chan |
CSCds38362 | Memory corruption suspected cos of MGCP Optimization |
CSCds38961 | addsset error message does not identify the error |
CSCds39361 | When a brand new BSC is inserted, the card is kept resetting |
CSCds40981 | Add delay in initialization of equalizer |
CSCds44195 | Before deleting a ds1 line, there is no checking for D-chan |
CSCds45221 | Interop problem between 5300 with G.729a |
CSCds45677 | lsdlsapstats stop after 11.168 |
CSCds45679 | lsmacsapstats ends abruptly with vb_ptr is null |
CSCds45979 | Need to make upgrade image as default after all SM upgd is complete |
CSCds46302 | Blank nodename unless use cnfndinf once |
CSCds51759 | Received control packets are not reported in ACR message |
CSCds51773 | The average delay calculated for VoIP call is wrong. |
CSCds52305 | SCC failed on SAR-ABM Diags test |
CSCds53506 | RMCP plays tone at 50 db loss |
CSCds55180 | FmOpen ret -1 shouldn't show up |
CSCds55898 | MGX responds with an MRJ for incorrect RCCP message parameters |
CSCds59353 | Packetization period not changing with MGCP p: parm |
CSCds59641 | Add Loop IP for call server |
CSCds61598 | MGX responds with an NLS message to an incorrect RLS message |
CSCds63438 | Incorrect cleanup of call that is set to receive only mode. |
CSCds63535 | No error when changed to E1 config on DMC card |
CSCds64201 | No security key for Image download for SCC,BSC and NSC |
CSCds66150 | Default for ECAN and VAD has changed to OFF |
CSCds66228 | Task wait routine can timeout prematurely |
CSCds68108 | DS1 Admin status show green after reset when it is down |
CSCds68402 | g72632k in mgx8260 interop with other BUs |
CSCds69368 | Messages from MGX contain DS0s in 1-base for E1 config |
CSCds69569 | Edit Field in System not showing valid messages |
CSCds69751 | Number Field in System in WebViewer not accepting valid values |
CSCds70722 | RTP Port range needs to be increased to 64K |
CSCds70791 | MGCP Core is not being modified. |
CSCds70917 | Block UDP traffic from going to the TCP IP stack for loop IP |
CSCds71638 | MGX responds to an RLS request for a non-existing modulo Number |
CSCds72952 | Download file on the web only accept scc |
CSCds73535 | RM does not send DelChanAck when a call is deleted after eth is del |
CSCds74763 | Add web support for loop IP |
CSCds74910 | NSC sometimes takes longer than usual to boot |
CSCds75122 | After configuring the LoopIP, we can not ping the default router |
CSCds75131 | Default route is assigned to be the Loopback IP after every reset |
CSCds75195 | Need to delete the route when LoopIP Mask is changed |
CSCds75427 | Error message on dbbkup is misleading - 0-based -> 1-based |
CSCds76516 | SDP codec for G.729a is 0 should be 18 |
CSCds77735 | Prevent accidentally programming card with wrong image |
CSCds80107 | Call count goes negative on ethernet trunk |
CSCds83251 | DMC cards cause service cards (BSC/NSC) to fail |
CSCds83292 | Online help swcd command description not correct |
CSCds84753 | Remove Psuedo IP from web |
CSCds84769 | Static need remove form Web Viewer since no support |
CSCds85401 | Workaround for inaccurate clock control |
CSCdr10211 | C-Bit related fields should be removed from WebViewer |
CSCdr77371 | System clock interrupt calls taskIdSelf() |
CSCds10493 | IPDC-Incorrect CauseCode 11, when port busy. |
CSCds12891 | Check PIO to load appropriate FPGA image for BSC |
CSCds16701 | CLI - wrong error message for chipdcpssip |
CSCds17135 | DLSAP Profiler allows me to add negative options. |
CSCds17861 | Add events info for TCG Invalid Event Log |
CSCds18788 | There a small memory leak on WebViewer |
CSCds20962 | SiwTaskWait() should support multiple tasks |
CSCds23042 | Redundant statement in SysChkSDRAM() |
CSCds25949 | Debug commands to activate and de-activate channels for AAL1 needed |
CSCds28665 | PRC signal handler can create deadlock |
CSCds29123 | list all is too slow if there is no object on the table |
CSCds32501 | MGCP:In T1 mode Connection are allowed belond 24 DS0 Channels |
CSCds32501 | MGCP:In T1 mode Connection are allowed beyond 24 DS0 Channels |
CSCds32819 | MGCP:DLCX just after CRCX causes 510 error |
CSCds33105 | Develop harness test for Fast MRPC asynchronous communication |
CSCds34681 | lsacts does not show active calls in some cases |
CSCds35667 | RMG prints an error while deleting on the STANDBY SCC |
CSCds37457 | If Module Does not Exist, Return NLS instead of MRJ to RLS message |
CSCds39059 | After SCC switch over, BC relay is not set as right state |
CSCds41158 | When EndChan number is larger than Start for invalid chan. send RSCS |
CSCds46404 | Improve the performance of the NSC switchover |
CSCds51737 | Async Ack for STN can not find the call object |
CSCds53495 | Invalid Channel number is SCS is not repeated in RSCS |
CSCds53874 | Dbm sync code errs while generating filenames |
CSCds54213 | Compiler warning: suggest parentheses around assignment |
CSCds54835 | SARtoASX test was bypassed. |
CSCds60608 | MGX responds to an incorrect RCR message with an ACR message |
CSCds63135 | addsrt cmd should be removed since its no longer supported |
CSCds63135 | addsrt cmd should be removed since its no longer supported |
CSCds65346 | Sw version is null in exception info when the sw version length >=19 |
CSCds66532 | When line is in LB, all channel status should be sent back as OOS |
CSCds67630 | CLI needs to block out Medium Type SDH for OC3 lines |
CSCds69459 | Need to use the DELETE Flag for all deleted dbm entries |
CSCds73802 | Re-send DelChanReq is DelChan fails for RM_STAT_RESYNC_. |
CSCds74740 | Online help for addvport command not accurate |
CSCds75832 | BSC that is inserted into chassis w/E1 mode does not go to mismatch |
CSCds80122 | Ping for the loopback IP address does not work |
CSCds82273 | DMC inserted onto chassis w/E1 config fails to go to mismatch |
CSCds14739 | Calls with service path should be torn down when that svc cd removed |
CSCds24535 | The OC3 function trace never got disable |
CSCds47572 | Need to disallow Copy() for anmt files |
CSCds73796 | Enable Echo Can. for all VoIP Calls |
CSCds81457 | Supress RMG debugging message in rmEpPath.c |
CSCdr92333 | Add more debug utilities |
CSCdr93652 | Exception information needs to be logged to a file in the disk |
CSCdr97169 | clrndcnf did not send shelf config clear trap to EMS |
CSCds05595 | RMG debugging tool I -- resource map and verification |
CSCds05953 | Need PING command on CLI. |
CSCds08406 | Enhance IDE drive |
CSCds22533 | Need Html Version for Web Viewer |
CSCds28345 | Enhancement on DS1 DB upgrade for BSC |
CSCds30781 | Add ALBM ingress capture FIFO capability as a debug enhancement |
CSCds39164 | Cannot delete (FmDelete) image files that do not exist in fileTable |
CSCds39495 | Reduce the response time to RMS message |
CSCds43346 | MCS - Need to update make files for gcc object files |
CSCds45936 | NSUP needs to carry variable protocol version number |
CSCds51602 | Provide CPU Utilization Profiler Tool |
CSCds52852 | Use taskdelay in DBM APIs when clrndcnf or clrcdcnf flag is on |
CSCds56283 | Txid for active call should show nothing when no calls |
CSCds60426 | RMCP does not modify the call if RCCP had all the necessary params |
CSCds63493 | Reserve enough memory for trace and avoid future boot upgrades |
CSCds63542 | Add CLI support for System Trace function calls |
CSCds67391 | Wrote small tool to aid in reproducing ide disk power failure probs |
CSCds68158 | Need iterative chds1lnecho command |
CSCds69029 | Remove ideStop global variable |
CSCds69360 | Provide Traps indicating loop up & down for admin status(IPDC) |
CSCds82261 | Possible problem with memory overwritten and deallocation errors |
The following sections provide sources for obtaining documentation from Cisco Systems.
You can access the most current Cisco documentation on the World Wide Web at the following sites:
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.
Cisco documentation is available in the following ways:
If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.
You can e-mail your comments to bug-doc@cisco.com.
To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:
Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools. For Cisco.com registered users, additional troubleshooting tools are available from the TAC website.
Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.
Cisco.com provides a broad range of features and services to help customers and partners streamline business processes and improve productivity. Through Cisco.com, you can find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online technical support, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.
Customers and partners can self-register on Cisco.com to obtain additional personalized information and services. Registered users can order products, check on the status of an order, access technical support, and view benefits specific to their relationships with Cisco.
To access Cisco.com, go to the following website:
The Cisco TAC website is available to all customers who need technical assistance with a Cisco product or technology that is under warranty or covered by a maintenance contract.
If you have a priority level 3 (P3) or priority level 4 (P4) problem, contact TAC by going to the TAC website:
P3 and P4 level problems are defined as follows:
In each of the above cases, use the Cisco TAC website to quickly find answers to your questions.
To register for Cisco.com, go to the following website:
http://www.cisco.com/register/
If you cannot resolve your technical issue by using the TAC online resources, Cisco.com registered users can open a case online by using the TAC Case Open tool at the following website:
http://www.cisco.com/tac/caseopen
If you have a priority level 1(P1) or priority level 2 (P2) problem, contact TAC by telephone and immediately open a case. To obtain a directory of toll-free numbers for your country, go to the following website:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
P1 and P2 level problems are defined as follows:
This document is to be used in conjunction with the documents listed in the "Obtaining Documentation" section.
AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, CiscoLink, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, Fast Step, Follow Me Browsing, FormShare,FrameShare, GigaStack, IGX, Internet Quotient, IP/VC, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, MGX, the Networkers logo, Packet, PIX, RateMUX, ScriptBuilder, ScriptShare, SlideCast, SMARTnet, TransPath, Voice LAN, Wavelength Router, WebViewer are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, Cisco, the Cisco Certified Internetwork Expert Logo, Cisco IOS, the Cisco IOS logo, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastSwitch, IOS, IP/TV, LightStream, Network Registrar, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries.
All other brands, names, or trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0011R)
Copyright © 2000, Cisco Systems, Inc.
All rights reserved.
Posted: Sat Sep 28 13:44:45 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.