Release 4.1 of the MGX 8220 interface shelf allows the user to perform the following management functions:
To perform these user interface functions, the MGX 8220 shelf offers a variety of physical access paths and a variety of protocols. Depending upon the function to be performed, there are four physical access methods that can be used.
The protocols that can be employed are:
A matrix of permissible user interface combinations is provided in Table 3-1.
UI Function | Physical Access Path | TCP/IP Protocols Used |
---|---|---|
Enter Commands using CLI | ASC Maintenance Port ASC Control Port In-band BNM T3 Port LAN Port | None SLIP, TCP, Telnet IP, TCP, Telnet IP, TCP, Telnet |
Configure/Collect Statistics and Configuration Files | ASC Control Port In-band BNM T3 Port LAN Port | SLIP, TCP, TFTP IP, TCP, TFTP IP, TCP, TFTP |
Enter Commands using SNMP | ASC Control Port In-band BNM T3 Port LAN Port | SLIP, UDP, SNMP IP, UDP, SNMP IP, UDP, SNMP |
Download Firmware | ASC Control Port In-band BNM T3 Port LAN Port | SLIP, TCP, TFTP IP, TCP, TFTP IP, TCP, TFTP |
The maintenance port is the upper RS-232 connector on the ASC line module. The connector is DB-25 (female). With serial line access via the maintenance port, the user interface prompt appears once the dumb terminal is connected and the system is powered up. No special software is required and the connection is made through a standard (not null modem) cable. This arrangement is shown in Figure 3-1. Entering commands via a dumb (or emulated) terminal is the only use for the maintenance port. The maintenance port is configured for 8 data bits, no parity, one stop bit, and 9600 bps.
The control port is the middle RS-232 connector on the ASC line module. The connector is an RS-232 DB-25 (female). For this type of connectivity, the control terminal (PC or workstation) must support TCP/IP using a SLIP serial connection and the control port must have been previously configured with an IP address. The control terminal can be connected either locally or remotely using modems. When entering command line commands through the control port, the user interface prompt appears when the user performs a Telnet login to the port's IP address.
The LAN port on the ASC is an Ethernet AUI port.
The control and LAN ports support Telnet (for CLI), TFTP and SNMP sessions as indicated in Table 3-1. Use of the control port is shown in Figure 3-2.
If you have multiple devices to which you want to log into to configure, you might want to connect your workstation or PC to a terminal server, that can dial out to multiple devices. Figure 3-3 illustrates a possible scenario for terminal server control port access.
Figure 3-4 shows how the LAN port is connected.
In-band access uses a portion of the bandwidth of the MGX 8220 shelf/BPX T3 connection by reserving a number of ATM virtual connections for network management functions.
(See Figure 3-5.) For this type of connectivity, the control terminal (PC or workstation) is connected through the BPX network and must support TCP/IP and the in-band port on the BNM must have been previously configured with an IP address. When using the in-band port to enter CLI commands, the user interface prompt appears after the user performs a Telnet login to the port's IP address.
The combination of account, password, and privilege level determines which commands the user can execute.
Before a user can be logged in, the user must have a previously assigned account, password, and privilege level. The account (userID) and privilege level are assigned using the adduser command. There is a default password which is used the first time a user logs in. When logged in, the user can change the password to a personal password with the cnfpwd configure password command.
Each user is assigned an account which is known by its userID which is specified as a parameter in the adduser command. The userID consists of up to 12 alphanumeric characters including letters, numbers, a hyphen, and an underscore. UserIDs are case sensitive.
When a user attempts to log in, the system prompts for a valid userID.
The MGX 8220 shelf permits one superuser account and 63 user accounts. The MGX 8220 shelf ships with a preconfigured superuser account (can also be changed by superuser).
All commands have an assigned privilege level. A command can only be executed by a user whose privilege level is equal to or above the privilege level of the command. There is one superuser privilege level and six user levels designated 1 through 6 (with 1 being the highest).
The password must consist of 6 to 15 characters. Only letters, numbers, a hyphen, an underscore, and spaces are allowed. The password is case-sensitive. For security, the password is not displayed as it is entered.
When a user attempts to log in, the system prompts for a valid password after the userID prompt has been entered. The user must respond with the account's valid password.
The following paragraphs describe how to setup the various user interface access paths. Initiating commands to the shelf involves providing the correct user password.
When no user is logged into the system the prompt is:
login
:password
:The user must respond with the appropriate password followed by the ENTER key. The first time a new user logs on, the system requires a password to be entered. A user can change the password at any time. When a correct password has been entered, the following prompt appears:
card number:
Enter the slot number of the card to receive the commands followed by the ENTER key. The normal command prompt will appear and commands for the specified card/slot can be entered.
To issue commands to another module, the user must issue the cc (change card) command
followed by the ENTER key.
1. After setting up and powering up the MGX 8220 shelf (refer to Chapter 5, "Service Configuration "), a CLI prompt appears on the terminal connected to the maintenance port.
login:
2. Upon successful login, the standard CLI prompt showing the node name assigned to the shelf, the shelf number, logged in slot number, logged in card type, and status is displayed.
(nodeName.shelf#.slot#.cardType.cardStatus>)
myshelf.1.6.FRSM.a > (FRSM in slot 6 with active status)
3. At the prompt, CLI commands can be entered.
nodeName.shelf#.slot#.cardType.cardStatus>
Before you can access MGX 8220 using the control port, LAN port or in-band virtual connection, you must configure IP addresses for each of these destinations on the ASC card. To configure IP addresses, proceed as follows:
1. Establish a CLI connection to the shelf (either over the maintenance port or a port which has previously been configured with an IP address).
2. At the login:
prompt, enter your userID.
3. At the password:
prompt, enter your password.
4. At the card number:
prompt, enter the slot number (3 or 4) of the ASC card. For example:
card number:
3
nodeName.shelf#.slot#.cardType.cardStatus>
5. At this prompt, enter a cnfifip command to configure the control port, LAN port or in-band port IP address.
For the control port and Ethernet port the MGX 8220 shelf is now configured for you to access the unit via the specified port. In Chapter 3, refer to the following sections, "Connecting via the Control Port" and "Connecting via the LAN Port" for details. For in-band access, you need a connection across the network. Refer to the following section in Chapter 3, "Connecting via an In-band Connection", for details.
There are two methods of connecting to the control port. They are:
The procedures are described below.
You can use a PC to access the shelf via Telnet, SNMP, or TFTP by completing the following steps:
1. Setup the control port on the MGX 8220 shelf using cnfifip and interface type of 28 as described in the previous section, "Setting Up IP Addresses for Control Port, LAN Port or In-band Access".
2. Make sure the PC has TCP/IP installed and is configured for SLIP communication.
3. Configure the PC COM Port to match the control port (data rate, parity, and so on).
4. Using the control port IP address, ping MGX 8220 to check connectivity.
5. Start the Telnet application for entering CLI commands, the SNMP manager application for managing MGX 8220 through SNMP commands, or start the TFTP application to configure or collect statistics.
If the workstation used for entering commands is to be connected over a terminal server complete the following steps:
1. Setup the control port on MGX 8220 using cnfifip with an interface type of 28. Refer to the section, "Setting Up IP Addresses for Control Port, LAN Port or In-band Access", in this chapter.
2. Make sure the terminal server has TCP/IP installed and is configured for SLIP communication.
3. Configure the terminal server RS-232 port to match that of control port (data rate, parity, and so on).
4. Setup the IP address of the control port of the terminal server (RS-232) to that of MGX 8220 control port ID address.
5. Using the control port IP address, ping from the X-Term workstation to MGX 8220 to check connectivity.
6. Using the control port IP address of the MGX 8220 shelf as the destination address, start the Telnet application for entering CLI commands, the SNMP manager application for managing MGX 8220 through SNMP commands, or start the TFTP application to configure or collect statistics.
Before you can access MGX 8220 using the in-band method, you must set up or add a connection across the network. To configure a connection to MGX 8220 that will terminate on the in-band port of the ASC card, proceed as follows:
1. Configure the MGX 8220 in-band IP address using cnfifip with an interface type 37. Refer to the section, "Setting Up IP Addresses for Control Port, LAN Port or In-band Access", in this chapter.
2. Management connection end-points are already configured on the MGX 8220 shelf. The reserved end-points for management purposes are VPI = 3 and VCI = 8 to 15.
3. Add a connection from the BNI connected to the management terminal (directly or indirectly) to the BNI in the BPX connected to the MGX 8220 shelf using a destination address of VPI = 3, and VCI = 8 to 15.
4. Using the in-band IP address of the MGX 8220 shelf as the destination address, start the TELNET application for entering CLI commands, the SNMP manager application for managing MGX 8220 through SNMP commands, or start the TFTP application to configure or collect statistics.
The LAN port allows the shelf to be connected to an Ethernet network using an appropriate transceiver. Thus a workstation connected to the Ethernet network can communicate directly with the MGX 8220. The port should be given an IP address to allow TCP/IP protocols to be used.
1. Setup the LAN on MGX 8220 using cnfifip with an interface type of 26 as described above.
2. Make sure the Ethernet workstation has TCP/IP installed and is configured for TCP/IP communication.
3. Start the Telnet application for entering CLI commands, the SNMP manager application for managing MGX 8220 through SNMP commands, or start the TFTP application to configure or collect statistics.
The Command Line Interface (CLI) uses a simple alphanumeric terminal and employs the concept of a system prompt to which the user types in commands.
The CLI also employs the concept of a user being logged into a particular module (slot) in the
MGX 8220 shelf and all commands entered are assumed to apply to that module (slot). In this way the CLI can be used for managing both the core cards and the service modules.
For security, logging in involves entering a correct preassigned password which allows the user access only to commands of a specified privilege level or below.
For information on performing some of the management functions using the StrataView Plus Connection Manager and Equipment Manager, see the Cisco StrataView Plus Operations Guide.
One command that must be entered using the CLI is the Configure Interface IP address (cnfifip). Since a control station, including StrataView Plus, uses an IP address to communicate with the shelf, the various ports on the shelf must first be assigned IP addresses using the cnfifip command.
Each CLI command and its syntax and privilege level is provided in the Cisco MGX 8220 Command Reference.
This procedure must be performed on the BPX at BOTH ends of the connection ("A" and "B"). This connection is established only once per shelf.
On the BPX:
1. Perform an uptrk command to enable the T3 line that connects to your MGX 8220 shelf.
2. Perform a cnftrk command.
3. Perform an addshelf command to enable the port to the MGX 8220 shelf.
The MGX 8220 shelf provides the ability to manage the shelf through Simple Network Management Protocol (SNMP) commands. These commands are issued from an SNMP Manager which accesses the MGX 8220 shelf either through the Ethernet port, the control port, or in-band connection.
Each ASC and service module in the shelf contains an SNMP agent and a Management Information Base (MIB) for that module. The SNMP agent responds to GET, GET NEXT and SET commands from the SNMP Manager, thereby providing the user with the ability to interrogate and update the MIB.
All messages from the SNMP Manager are checked for the correct Community String as follows:
The MIB resides with an object ID of axis under the strataCom branch of the SNMP tree structure (1.3.6.1.4.1.351.110) as shown in Figure 3-6. The MIB consists of five major sections:
The axisSystem section consists of three sub-sections.
1. The axisShelf contains information about the shelf as a whole such as nodename, time, date, and so forth.
2. The axisAsm contains the shelf alarm table. This table contains the threshold, severity and status of alarms in the shelf.
3. The axis redundancy group contains information about the redundant configurations within the shelf.
The cardGeneric section contains objects that are common to all card types. This section contains five subsections.
1. The cardGeneric section contains objects that are common to all card types. This section contains five sub-sections. cardInformation contains card type, card slot, serial number, hardware and firmware revision number, and so forth.
2. cardInterface contains a list of physical interfaces and service types available on a card.
3. cardSelfTest contains a selftest enable/disable object, the interval between selftests, and the results of the last selftest.
4. controlMsgCounter contains the current values of the control SAR counters (control frames transmitted and received, control cells discarded, and so forth).
5. sarChannelCounter contains the current values of the channel SAR counters. These counters are for ATM cells and are maintained on a per VC basis.
This section contains objects that are specific to a particular type of card. The cardSpecific section contains seven sub-sections.
1. bnmClockConfig contains the primary and secondary clock sources, the status and impedance of the external T1/E1 clock input.
2. bnmAddressTranslation contains shelf, slot and channel mapping data.
3. bnmATMCounters contains the ATM counters on the BNM card. These counters contain the current values of ATM cells transmitted, ATM cells received, and so forth.
4. ASC LMI signaling information.
5. The fifth is currently unused.
6. Service module feature information.
7. Service module rate control configuration data.
The axisLines section consists of four subsections.
1. serialInterface contains information about the serial (maintenance and control ports) lines in the shelf.
2. ethernetInterface contains information about the Ethernet LAN port in the shelf.
3. dsx1 contains information about configuration, alarm configuration, alarm status and counters for the DS1 lines.
4. dsx3 contains information about configuration, alarm configuration, alarm status and counters for the DS3 lines.
The MGX 8220Services sections consists of the MGX 8220 service. This section contains information about frame relay channel configurations, configurable parameters, and LMI signalling. This section also contains similar MIB objects for ATM services.
The services for frame relay are further organized as shown in Figure 3-7.
The MIB is distributed as a text file (ASN.1) on a diskette which can be printed and used to compile the MIB into an SNMP Manager. The MIB (and hence the MGX 8220 shelf) can also be managed from StrataView Plus (Release 8.1 and higher). For complete details of managing the shelf from StrataView Plus, refer to the Cisco StrataView Plus Operations Guide.
The MGX 8220 shelf in Release 4.1 supports the transfer of data files between the shelf and a workstation using Trivial File Transfer Protocol (TFTP). The functions provided by these file transfers are the configuring and collection of statistics and the downloading of MGX 8220 firmware.
In order to perform a file transfer the workstation must establish connectivity with the shelf either through the control port (using SLIP) or through the in-band port. In both cases TCP/IP protocol is employed and the shelf must be assigned an IP address. For details on establishing connectivity, refer to the following section in this chapter, "Setting Up Management Connectivity to the MGX 8220 Shelf".
MGX 8220 shelves are shipped with the latest version of the firmware already pre-loaded.
MGX 8220 firmware upgrades can be downloaded over the network. Firmware and firmware upgrades for the MGX 8220 shelf are also distributed as a Firmware Media Kit on diskettes. The contents of the kit are:
TFTP, either through the control port or in-band ATM, is used for downloading firmware from a workstation into the MGX 8220 modules.
The host uses the following command sequence to download the firmware:
1. tftp <dest_IP_add>
2. tftp> bin
3. tftp> put <source_file_name> <dest_file_name>
If the download process is disrupted for a timeout or other such errors, restart the TFTP download process without resetting the MGX 8220 shelf.
If there is a hardware or system failure that requires resetting the card being downloaded, the firmware must be downloaded using the backup boot procedure. This is a two step procedure.
Step 2 Download the on-line firmware.
If a backup boot procedure becomes necessary, contact technical support for assistance.
After the firmware file has been transferred completely and successfully, the module should be reset for the downloaded firmware to take effect.
Configuring statistics specifies to the shelf which statistic counters are to be collected. A file is constructed which lists the statistic counters to be collected and is downloaded into the shelf using TCP/IP TFTP.
Collecting statistics causes the statistics to be transferred as a data file to the workstation. The workstation first requests the statistics and the MGX 8220 shelf responds by uploading the statistic file to the workstation. A list of statistics counters for each card type is provided in Appendix B, "Specifications ".
The method of collecting statistics in MGX 8220 conforms to the standards employed in IGX, IPX and BPX nodes. StrataView Plus (Release 7.2 and later) supports the standard TFTP method of configuring and collecting statistics and can be used on the workstation which is attached to the MGX 8220 shelf for this purpose. StrataView Plus provides a convenient and easy-to-use graphical user interface (GUI) for both configuring the statistics to be collected and actually collecting those statistics from the MGX 8220 shelf. Using StrataView Plus relieves the user of knowing and constructing the file formats required for correctly transferring the statistics files.
Each type of statistic collected in WAN switching networks is categorized under a major grouping known by an object type name and an object type number and minor grouping known as a sub-type. Within the sub-type, the statistic has a statistic type number. For example, the statistic "ATM Cell Header HEC Errors" has an object type name of IPX-ATM, an object type of 2, a sub-type of 1, and a statistic type of 45. This combination of groups and type number uniquely identify a particular type of statistic.
Each MGX 8220 statistic can be configured individually for collection. To configure statistics, the workstation transfers a file (filename = enable.stats) using TFTP to the MGX 8220 shelf which specifies those statistic types to be collected. The specified statistics are grouped by Object Type, then Object Sub-type. Multiple Object types each containing multiple Object Sub-types each containing multiple Statistic types can be specified in one file.
To collect statistics from the MGX 8220 shelf, the workstation uses the following TFTP command to issue a request in the form:
Get Nodename.mmddyyhhmmwhere
Upon receipt of this message, the shelf responds with a file containing the collected statistics.
Field Description | Field Size |
---|---|
Fixed Header Section | |
Domain number of the MGX 8220 shelf | 1 byte |
Node number of the MGX 8220 shelf | 1 byte |
Release number (example, 725a for release 7.2.5.A) | 4 bytes |
Status byte | 1 byte |
Peak Flag | 1 byte |
File collection interval | 1 byte |
Bucket interval | 1 byte |
Number of Object Types | 1 byte |
Data Dependent Section | |
Object Type identifier | 1 byte |
Number of Object Sub-types | 2 bytes |
Object Sub-type identifier | 1 byte |
Key information | variable length |
Number of Stat types | 1 byte |
Stat type | 1 byte |
Stat value | 4 bytes |
Peak value | 4 bytes |
REPEAT Stat type, Stat value and Peak value for each bucket until number of stat types is satisfied | n bytes |
REPEAT Object Sub-type section | n bytes |
REPEAT Object type section | n bytes |
The MGX 8220 shelf provides Save and Restore functions which are performed using the TFTP facility.
The Save function allows a user to copy a service module's current configuration file (which is saved on a disk on the ASC) to a network file system. The Restore function allows a user to copy a service module's configuration file from the network file system to the ASC's disk. Using these functions, the configuration files for MGX 8220 service modules can be backed up to an independent network system and later restored if the configuration files in the MGX 8220 shelf become lost or corrupted or if the configuration needs to be restored to a previous version.
The TFTP Get command is used to save a configuration as follows:
where configuration filename is:
AXIS_SM_1_<slot number>.PRI.<service user password>
For example:
will save the configuration file for the service module in slot 5.
The TFTP Put command is used to save a configuration as follows:
where configuration filename is:
AXIS_SM_1_<slot number>.PRI.<service user password>
For example:
will place the configuration file onto the service module in slot 5.
Posted: Mon Jan 15 16:35:36 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.