|
This chapter provides a physical description of the IGX 8 and an introduction to each component's function. It describes the IGX 8 rack-mount and stand-alone enclosures, AC and DC power sources, cooling system, backplane, and system bus. The description of each card includes function, system interconnect, and faceplate indicators. A brief description of optional peripherals and third-party equipment appears at the end of the chapter. System specifications, such as protocols and standards, are listed in Appendix A.
For all matters relating to installation, troubleshooting, and repair and replacement, refer to the IGX 8 Installation Guide.
Other manuals that relate to IGX 8 operation are:
An IGX 8 system is available in the following models:
The IGX 8 rack-mount system can be mounted in a standard 19" rack, such as a STRATM cabinet. This installation uses standard EIA spacing between vertical rails. Also, the vertical spacing between components, such as the card cage and fan tray, must be in the range 0.047" to 0.077" (0.119 cm to 0.196 cm). A description of the STRATM cabinet appears in the IGX 8 Installation Manual. The IGX 8 rack-mount cabinet contains:
Figure 2-1 and Figure 2-2 show the rack-mount IGX 8 in front and back views, respectively.
The IGX 8 stand-alone system comes in a free-standing enclosure with a tool-operated front door latch. Four plastic feet support the IGX 8 stand-alone at its base. No mounting brackets are on the cabinet.
The stand-alone enclosure holds all of the system modules, power modules, power supplies, and cooling fans. The IGX 8 cabinet contains one eight-slot card cage with a backplane into which front cards plug, three auxiliary slots, a fan tray with four fans, an exhaust plenum, a power entry module, and an optional AC Power Tray that holds up to four power supplies. Figure 2-3 is a front view of the IGX 8 stand-alone.
This section describes the Power Entry Back Card (PE-BC), the Power Entry Module (PEM), and the fan tray power connections to the PE-BC.
For all IGX models, the power source supplied to the unit can be either AC or DC. In a unit that uses a DC source, the power cord is attached to a Power Entry Module (PEM). The PEM provides circuit protection for the DC voltage. In a unit that uses an AC source, an optional AC power supply module is necessary for generating the DC voltages for the backplane and cooling fans.
Each system comes with a factory-installed PE-BC. In both AC-powered and DC-powered systems, the PE-BC connects the -48 VDC primary power for the system to the backplane. It also routes power to the fan tray. Because of its shape, the PE-BC is also called the "E card." In an AC-powered system, a cable from the supply module plugs into the PE-BC. In a DC-powered system, the PE-BC has at least one factory-installed PEM. Figure 2-4 shows the location of the PE-BC. A PE-BC slot has no number. It resides between back card slot 1 and the side of the cabinet. Figure 2-5 shows a PE-BC for an AC-powered system.
A PEM is a small, factory-installed card that plugs into a connector on the PE-BC. (The PEM plugs into the same connector as a cable from the power supply module in a system using an AC source.) A PEM takes the DC power directly from the DC power source in the building, filters it, and passes it to the PE-BC. A PEM also has a circuit breaker for turning the power on and off and a strain-relief clamp for the DC power cable. Figure 2-6 shows a PEM plugged into a PE-BC in a non-redundant system. It also shows the blank plate that covers an unused connection in a non-redundant system. Redundancy of DC sources and PEMs lets the system continue to operate in case one of the two independent DC branch circuits fails. The IGX 8 Installation Guide describes the DC power setup.
In an IGX 8, the fan tray connects to the "Fan 1" connector on the PE-BC (see Figure 2-6).
This section introduces the AC power system and explains the concept of redundancy.
For a node to use an AC power source, an AC power supply system is necessary. The IGX power supply housing holds up to four, 400-Watt power supplies. The AC system provides the system with -48 VDC from 100 to 240 VAC input. The AC power supply housing is between the card cage and the side wall of the node. The IGX 8 has one or, with AC redundancy, two AC power inputs.
Two types of redundancy exist: power source redundancy, in case one AC circuit fails, and AC power supply redundancy, in case a supply fails. Figure 2-7 shows two AC inputs.
The minimum requirement for an AC-powered system is one AC source and one power supply. One supply is adequate for four cards unless power supply redundancy is specified. See Table 2-1. Figure 2-8 shows the power supply slot designations and external parts of the supplies.
Figure 2-8 shows a dual-input system. Facing the back of a dual-input system, AC Input A is on the left. AC Input B in on the right. In a dual-input system, the Input A supplies power supply slots A and B. Input B supplies power to slots C and D. A single AC input system does not have these distinctions: the single input receives AC power for supplies A through C.
Two types of redundancy exist in the AC-powered system. One redundancy is that of AC power inputs. A redundant AC power source from a building circuit that is independent of the other AC circuit provides backup if one AC circuit at the site fails. The other redundancy is that of the 400-Watt power supply modules. Redundancy of the 400-Watt power supplies provides a backup if a power supply fails.
In supporting single and dual AC inputs, power supply arrangements differ, as follows:
Table 2-1 shows the minimal 400-Watt unit requirements for the different IGX systems. The factors that determine the number of supplies are as follows:
In Table 2-1, the System column shows the number of AC inputs. The Number of Cards column shows the number of cards at the cutoff point for more supplies. The Supply Redundancy column indicates whether the configuration includes a redundant supply for backup. For columns A through D, an X shows that the corresponding slot in the power supply housing must have a power supply to meet the configuration requirements. The part number for a power supply is 400W-PS-AC.
System | Number of Cards | N+1 Supply Redundancy | A | B | C | D |
---|---|---|---|---|---|---|
1 AC Input | 4 or less | No | X |
|
|
|
4 or less | Yes | X | X |
|
| |
more than 4 | No | X | X |
|
| |
more than 4 | Yes | X | X | X |
| |
2 AC inputs | 4 or less |
| X |
| X |
|
more than 4 |
| X | X | X | X |
Fans mounted in a fan tray cool the system. In an IGX 8, the fan tray resides immediately below the card cage. Each fan tray contains four fans. Figure 2-9 illustrates the fan tray.
Normally, an exhaust plenum resides at the top of each unit. Cooling air for the cards enters through grilles on the front of the fan trays and exits through the rear of the exhaust plenum
To maintain correct air flow and reduce Radio Frequency Interference (RFI) and Electromagnetic Interference (EMI), all unused back card slots must be covered with the blank faceplates that StrataCom provides.
An IGX card cage has 8 active card slots (the PE-BC slot is not numbered in this scheme) on each side of the backplane. It also has space for three spare cards.
In most cases, front slots contain data processing cards (processors, service modules, etc.), and the back slots contain system interface cards. The plug-in cards in the front slots are the system unit cards. The cards in the back slots are the network trunk and user interface cards. The "Card Groups" section, later in this chapter, introduces these card and the sections that follow provide detailed information about each card.
Figure 2-10 and Figure 2-11 show typical card placements. Most cards can reside in any vacant slot. Only the NPM and SCM have specific slot assignments.
The IGX backplane (midplane) includes eight, 216-pin connectors. Each front card plugs into the backplane. Furthermore, except for the NPM in slot 1 and slot 2, each front card directly connects to its corresponding back card in the open area below the backplane. Thus, the upper connector on a front card plugs into the backplane, and the lower part of the front card directly plugs into a back card. The NPMs also plug into utility bus connectors beneath the backplane.
In addition to providing the physical connections between the cards, the backplane contains the IGX system bus.
The IGX system bus resides on the backplane. The system bus provides the following:
As a safeguard against card driver failure or bus failure, the backplane contains redundant system buses. The backplane also contains fuses to protect it from catastrophic electrical damage. (See the chapter on repair and replacement in the IGX 8 Installation Guide.
A utility bus is used to interconnect redundant processor cards in a node. In an IGX 8, the two-slot utility bus UBS-2 interconnects the two processor cards. It occupies the positions of the lower connectors in slots 1 and 2.
The IGX currently utilizes the following functional card groups:
This section introduces these card groups. The sections that follow contain information on the function of each card.
Table 2-2 lists the front cards that can be used in IGX 8 nodes. Table 2-3 lists the back cards that can be used in IGX 8 nodes. In addition to the front and back cards, the IGX 8 supports the use of Adapter Card Modules (ACMs). These cards attach to existing IPX 16/32 service module cards and perform the adaptation necessary to allow IPX 16/32 front cards to operate in an IGX 8, 16, or 32 system. Note that IPX 8-specific cards cannot be upgraded for operation in an IGX 8. Beyond this, IPX back cards can operate in an IGX system without modifications.
Card Acronym | Card Name |
---|---|
NPM | Nodal Processor Module |
NTM8 | Network Trunk Module |
BTM | Broadband Trunk Module |
CVM8-ADPCM | Channelized Voice Module, ADPCM |
CVM8-T1 | Channelized Voice Module, T1 |
CVM8-E1 | Channelized Voice Module, E1 |
FRM8 | Frame Relay Module, V.35/X.21 |
FRM8-2 | Frame Relay Module, Port Concentrator only |
FRM8-6 | Frame Relay Module, w/6 chan. |
FRM8-31 | Frame Relay Module, w/31 chan. |
FTM | FastPAD Trunk Module |
HDM | High-Speed Serial Data Module |
LDM | Low-Speed Serial Data Module |
ARM | Alarm Relay Module |
Card Acronym | Card Name |
---|---|
SCM | System Clock Module |
AIT-E3 | E3 Trunk Interface Card |
AIT-T3 | T3 Trunk Interface Card |
BC-E1 | E1 Interface Card |
BC-T1 | T1 Interface Card |
BC-Y1 | Y1 Trunk Interface Card |
BC-J1 | J1 User (Circuit) Interface Card |
BC-SR | Subrate Trunk Interface Card |
FRI | Frame Relay Interface Card; V.35, T1/E1, X.21, 2-X.21 |
FPC | FastPAD Card; V.35, T1/E1, X.21 |
SDI | Synchronous Data Interface:
|
LDI | Low-Speed Data Interface
|
ARI | Alarm Relay Interface |
FBoth front cards and back cards have faceplates with indicator LEDs and, on some front cards, push-button controls. In addition, back card faceplates have the cable connectors. In slots where no back card exists, a blank faceplate must reside to contain Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI) and to ensure correct air flow.
The LED indicators are on the front and back card faceplates. The AC power supplies also have LED indicators. Each plug-in card has both a green ACTIVE LED and a red FAIL LED at the bottom of the faceplate. In general, the meaning of each LED is indicated in Table 2-4. Some other cards have additional indicators, connectors, or controls and are described in the forthcoming sections.
Indicators | Status | Meaning |
---|---|---|
FAIL | ON Steady | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
FAIL | Blinking | On an NPM in a redundant system, this indicates that the card is in an update state. |
ACTIVE | ON steady | When steadily on, this indicates the card is active and carrying traffic or processing data. |
ACTIVE | ON momentarily | When momentarily on, indicates the card did self-test. |
BOTH | OFF | Indicates the card part of a redundant pair and is in the standby mode or not being used at all. |
BOTH | ON | Indicates the card failed but remains active because no standby card is available. In the case of an HDM or LDM card, this could indicate that one or more of the data channels failed, but the others are still active. |
The processor card group consists of the Nodal Processor Module (NPM) and the System Clock Module (SCM). In conjunction with the system bus, the processor card group controls communication between the cards in the node. This card group also controls communication to other nodes in the network. System timing, network control, and status reporting functions are also performed by this card group.
The Nodal Processor Module (NPM) is a microprocessor-based system controller that contains the software for controlling, configuring, and monitoring the IGX 8. It also maintains the alarm and event logs and controls statistics gathering. The NPM communicates with the other system plug-in cards over the control bus. Figure 2-12 illustrates the relation of the NPM to other parts of the system.
In summary, the NPM performs the following major functions:
The NPM communicates with all other nodes through a trunk that uses a reserved, low-speed data link of about 200 packets/sec. The NPMs communication link with other nodes carries information about new connections, topology changes, and rerouting.
Two versions of the NPM exist. The B versions of the NPM require a certain, minimal level of 8.1 software to support the +5 VDC flash memory. Both versions of the NPM can reside in the same node if the system software supports the B version. Refer to the release notes that came with this manual for the specific 8.1 version.
The NPM includes non-volatile flash EEPROM, which permits new software releases to be downloaded over the network, and battery-backup RAM (BRAM) for storing system configuration data. These memory features maintain system software and configuration data after a power failure, so the system quickly resumes operation after power returns.
The NPM or NPM-B has the following processor and minimum memory sizes:
An IGX 8 has one NPM in a non-redundant system or two NPMs in a redundant system. In a non-redundant system, an NPM resides in either front slot 1 or front slot 2. For a redundant system, NPMs reside in slots 1 and 2. The NPM plugs into the system bus backplane. A utility bus in the backplane connects the NPMs in a redundant system.
The faceplate of the NPM has a green ACTIVE LED and a red FAIL LED. See Figure 2-13 . The NPM monitors its own activity and, if a failure is detected, the FAIL LED is lit. If the node has redundant NPMs, the on-line NPM is indicated by the lit ACTIVE LED, while the standby NPM has no lit indicators. In addition to the status LEDs on the NPM faceplate, information on any NPM can be displayed at a terminal by executing the dspcd command.
The SCM plugs directly into the NPM card in slot 1. The NPM and SCM card set are the backbone of the IGX system. The NPM controls and monitors the SCM control buses. A single SCM can support redundant NPMs.
In addition, the SCM provides:
The SCM circuits include of the following:
The two serial RS-232 ports provide connection to network management terminals and modems for remote access to the node. In conjunction with the SCM, the NPM also supports a high-speed Ethernet LAN port for faster system statistics transfer between the node and a StrataView Plus NMS workstation. This port conforms to the requirements of IEEE standard 802.3 for Ethernet.
The SCM has duplicates of the internal clock circuitry and its associated phase lock loops and NPM-related control circuitry. One operates off the System A Bus, and the other operates off the System B Bus. Both circuits are independent and are monitored separately to provide complete backup if a circuit fails (FAIL lamp comes on). However, since both the System A bus and System B bus clock circuits exist on a single card, removing the SCM disrupts system operation. The lower priority SCM circuits are not duplicated. The lower priority circuits are the external clock input, control and auxiliary ports, and monitoring circuits for power supplies, cabinet temperature, and fans. A failure in a lower priority circuit does not cause a system failure, but the SCM reports the problem.
The Ext Clock connector on the faceplate of the SCM provides an interface for an external source for a high-stability clock. This clock is configurable as the primary, secondary, or tertiary clock. This input is 1.544 MHz for T1 systems and 2.048 MHz for CEPT systems. In addition, one of the trunk or circuit line inputs may also serve as a source of timing for the node. If no clock source is selected, the clock source is the internal IGX clock.
Refer to Figure 2-14 and Table 2-7 for details on the SCM faceplate. When correlating the descriptions in the table with the callouts in the figure, read from the top down.
In addition to the clock functions, the SCM provides a pair of low-speed, serial communications ports. The CONTROL TERMINAL port is a bi-directional port for connecting the IGX 8 to a local network control terminal or to a modem for remote terminal connection. The AUXILIARY PORT connects to a maintenance log printer, an additional dumb terminal, an alarm message collector, external device window, or an auto-dial modem for automatic reporting of local IGX alarm conditions. This modem can be programmed to dial StrataCom ISC for assistance when a network alarm occurs.
Connector | Function |
---|---|
EXTERNAL CLOCK | DB15 connector for connecting an external source for the system clock. |
CONTROL TERMINAL | A DB25 connector for a VT100 or equivalent terminal for a basic network management terminal. It can also be connected to a dial-in modem for ISC or other network management dial-up access. This is a bidirectional RS232 communications port. |
AUXILIARY PORT | A DB25 connector for a system printer. Can also be used to connect to an out-dial modem or automatic reporting of alarms in the event the node becomes isolated. This is a bidirectional RS232 port. |
LAN AUI | Ethernet LAN connection for multiple, local StrataView Plus NMSs. This port uses a DB-15 connector called the Attachment Unit Interface (AUI) connector. This name reflects the industry standard term for a LAN interface. See Table 2-6 for the AUI pin assignments. |
PSM | Power supply monitor, cable supplied by customer. |
FAIL | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE | Indicates the card is in service with active circuits. |
Table 2-6 lists the pin assignments for the LAN connector.
Pin | Name | Pin # | Name |
---|---|---|---|
1 | Shield | - | - |
2 | Collision Presence + | 9 | Collision Presence |
3 | XMT + | 10 | XMT |
4 | Reserved | 11 | Reserved |
5 | RCV + | 12 | RCV |
6 | Power return | 13 | Power (+12V) |
7 | Reserved | 14 | Reserved |
8 | Reserved | 15 | Reserved |
IPX service/interface cards can be upgraded for use in an IGX 8. This allows the IGX to provide all the services of the IPX with cards of proven efficiency, functionality, and reliability. The upgrade is available only as a factory upgrade. The factory upgrade consists of an adding one of three possible Adapter Card Modules (ACM) and possible firmware or hardware modifications. Due to the complexity of the ACM, field upgrades of IPX cards are not possible.
Connecting IPX front cards to their corresponding back cards on the IPX requires the use of a utility or local bus. On upgraded IPX cards (IGX cards), the local or utility bus is not necessary.
The following IPX cards can be adapted for use in the IGX 8:
The IGX supports two types of trunk cards:
The NTM8 works with the following back cards:
The BTM works with the following back cards:
The Network Trunk Module for the IGX 8 (NTM8) coordinates the transmission of FastPackets across a trunk line to another node. Note that the NTM and NTM8 are functionally the same and that the NTM can operate in an IGX 8, but the NTM 8 cannot operate in an IGX 16/32.
NTM8 functions include the following:
An NTM8 can occupy any available front slot in the range 3 to 8. The choice of back card depends on the trunk interface type. All the service card slots may hold NTM8s.
For fractional T1 trunk lines, the NTM8 and BC-T1 card set can provide the interface. Fractional trunk interfaces use a group of 64-Kbps channels, which constitute a partial T1 trunk. For example, a 512-Kbps fractional T1 trunk might use every third channel from 1 through 24. Fractional trunks use the basic trunk frequency (such as 1.544 Mbps for T1) for the clock rate. The network operator makes the channel assignments.
Fractional E1 is the same as fractional T1 except that the channels are 1 to 15 and 17 to 31 (0 and 16 reserved) and the clock rate is 2.048 Mbps).
The NTM8 supports subrate trunks if a BC-SR back card and appropriate local bus are present. Subrate trunks interface to the digital transmission facility at trunk rates in the range 256 Kbps through 2.048 Mbps. Three interface connections are provided. These are RS449, X.21, and V.35.
The NTM8 can be configured for 1:1 redundancy by using a second, identical, card group and a Y-cable for connection to the trunk. All of the back cards support redundancy.
The faceplate of the NTM8 card has four LEDs. An ACTIVE LED indicates the card is active and functioning normally. An NTM8 card failure lights up the FAIL LED. The other two LEDs are a summary alarm for the back card conditions. A yellow MINOR LED indicates non-service interrupting faults or when statistical errors have exceeded a preset threshold. A red MAJOR LED indicates service-affecting failures.
Alarms/line conditions monitored by the NTM8 include those in the following list. To view packet line errors, use the dspplnerrs command. To see what packet line errors are configured for display, use dspplnstatcnf.
The T1 Trunk Interface Card (BC-T1) card terminates a single 1.544 Mbps T1 trunk line on the NTM8. The BC-T1 can reside in any rear slot 3-8 of the IGX 8. The BC-T1 connects directly to the NTM8.
The BC-T1 provides the following:
B8ZS supports clear channel operation because B8ZS eliminates the possibility of a long string of zeros. B8ZS is preferable whenever available, especially on trunks.
The BC-T1 supports two clock modes. These are normal clocking and loop timing. The system operator selects the mode through software control. Normal clocking uses the receive clock from the network for incoming data and supplies the transmit clock for outgoing data. This clock can be used to synchronize the node.
Loop timing uses the receive clock from the network for the incoming data and turns the receive clock around for timing the transmit data.
Figure 2-15 and Table 2-7 provide information on the faceplate of the BC-T1. When correlating the descriptions in the table with the callouts in the figure, read from the top down. The standard port connector is a female DB15.
Connector/Indicator | Function |
---|---|
T1 INPUT/OUTPUT | Female DB15 connector for T1 line. |
LOS light (red) | Indicates loss of signal at the local end. |
Red Alarm light (red) | Indicates loss of local E1 frame alignment or packet alignment (NTM8). |
Yellow Alarm light (yellow) | Indicates loss of frame alignment at remote end or loss of packet alignment (NTM8). |
AIS light (green) | Indicates the presence of all ones on the line. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE: light (green) | Indicates the card is in service with active circuits. |
The E1 Trunk Interface Card (BC-E1) provides an E1 trunk interface for the Network Trunk Module 8 (NTM8). The BC-E1 connects directly to the NTM8 and can reside in back slots 3 to 8 in an IGX 8. The BC-E1 provides the following:
The BC-E1 supports two clock modes. These are normal clocking and loop timing. The system operator selects the mode through software control. Normal clocking uses the receive clock from the network for incoming data and supplies the transmit clock for outgoing data. This clock can be used to synchronize the node.
Loop timing uses the receive clock from the network for the incoming data and turns the receive clock around for timing the transmit data.
Statistics are kept on most line errors and fault conditions, including the following:
Figure 2-16 shows and Table 2-8 lists status LEDs and connections on the BC-E1 faceplate. When correlating the table and figure items, read from the top down.
Connector/Indicator | Function |
---|---|
RX-TX | Female DB15 connector for XMT and RCV E1. |
RX | BNC connector for receive E1 line. |
TX | BNC connector for transmit E1 line. |
LOS light (red) | Indicates loss of signal at the local end. |
Red Alarm light (red) | Indicates loss of local E1 frame alignment. On an NTM8, indicates loss of packet alignment. |
Yellow Alarm light (yellow) | Indicates loss of frame alignment at remote end. On an NTM8, indicates loss of packet alignment. |
AIS light (green) | Indicates the presence of all ones on the line. |
MFRA light (red) | Indicates loss of multiframe alignment (E1 only). |
MFRY light (yellow) | Indicates loss of multiframe at remote end (E1 only). |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, StrataCom call the ISC. |
ACTIVE: light (green) | Indicates the card is in service with active circuits. |
The Subrate Trunk Interface Card (BC-SR) terminates subrate trunks on the NTM8. A subrate trunk uses only a portion of the E1 or T1 bandwidth. It is used primarily for tail circuits or where little traffic exists. A subrate trunk facility interface is a DCE interface, and the subrate channel acts like a synchronous data channel. Therefore, the IGX BC-SR always has a DTE configuration. Only leased lines are supported. Dial-up lines are not supported. Subrate trunks cannot pass clock signals between nodes.
The BC-SR provides the following:
Table 2-17 and Table 2-9 provide information on the BC-SR faceplate. When correlating the items in the figure and table, read from the top down.
Connector/Indicator | Function |
---|---|
RS-449/MIL 188 data connector | DB37 female connector |
X.21 data connector | DB15 female connector. |
V.35 data connector | 34-pin female MRAC connector |
LOS light (red) | Indicates loss of signal at the local end. |
Bad CLK light (red) | Indicates loss of clock or clock out of range |
Yellow Alarm light (yellow) | Indicates loss of packet alignment (NTM8) or frame alignment at remote end |
DSR light (green) | Indicates the DSR lead is high (ON) |
DTR light (green) | Indicates the DTR lead is high (ON) |
RXD light (green) | Indicates the receive data line shows activity |
TXD light (green) | Indicates the transmit data line shows activity. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE: light (green) | Indicates that the card is in service and that active circuits are present. |
Table 2-10 lists the data signals and EIA leads supported by the subrate interface.
Transmit | Receive | ||||
---|---|---|---|---|---|
Lead | Name | Interface | Lead | Name | Interface |
TX | Transmit data | All | RX | Receive data | All |
RTS | Request to Send | 188, V.35 | CTS | Clear to Send | 188, V.35 |
DTR/C | Data Terminal Ready | All | DSR/I | Data Set Ready | All |
LL | Local Loop | 188 | DCD | Data carrier select | 188, V.35 |
RL | Remote Loop | 188 | RI/IC | Ring Incoming Call | 188, V.35 |
IS | Terminal In Service | 188 | TM | Test mode | 188. V.35 |
SS | Select standby | 188, V.35 | SB | Standby indicator | 188 |
SF | Sig rate select | 188 | SI | Signalling rate | 188 |
The BC-Y1 back card provides a Japanese Y1 trunk interface for an NTM8. The BC-Y1 can reside in any slot 2-8 of the IGX 8. The BC-Y1 provides:
Loop timing uses the receive clock from the network for the incoming data and turns the receive clock around for timing the transmit data.
Figure 2-18 and Table 2-11 provide descriptions of the BC-Y1 status LEDs and connections on the faceplate. When correlating the items in the figure and table, read from the top down.
Connector/Indicator | Function |
---|---|
Y1Trunk INPUT/OUTPUT | DB15 connector for Y1 Trunk |
Line in | Y1 trunk input line |
Line out | Y1 trunk output line |
RX MON | BNC test connector for monitoring receive Y1 line |
TX MON | BNC test connector for monitoring transmit Y1 line |
LOS light (red) | Indicates loss of signal at the local end. |
Red Alarm light (red) | Indicates loss of local frame alignment. |
Yellow Alarm light (yellow) | Indicates loss of frame alignment at the remote end. |
AIS light (green) | Indicates the presence of all ones on the line. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE light (green) | Indicates that the card is in service and that active circuits are present. |
The card set works in the following arrangements:
Descriptions of broadband trunk implementation, ATM protocol, and cell and header formats appear in the System Manual.
The BTM/AIT card set can operate in either simple gateway or complex gateway mode. Complex gateway supports network interworking and allows all StrataCom frame relay interfaces to communicate. It requires release 8.1 or higher system software. The application of complex gateway is in tiered networks. For a description of tiered networks, refer to the System Manual.
Simple gateway supports frame relay connections that terminate on either an IPX or IGX in a flat network. Simple gateway does not support frame relay connections between the AXIS FRSM and the IGX FRM/FRI card set and does not require 8.1 system software.
No maintenance is required on BTM cards. If a card has either a solid or a confirmed intermittent failure, replace it. The only faceplate indicators are the ACTIVE and FAIL LEDs. For purposes of troubleshooting, the BTM/AIT card set is considered a trunk. The tstcon command does not work on a BTM because the card cannot be isolated from the IGX or the other, connected BTM.
A trunk loopback test is run when the BTM detects an integrated alarm. The loopback test verifies if the line or the card is faulty. A loopback test "pass" means the line is faulty and a line alarm is indicated. A loopback test "fail" means the card is faulty. In the case of a faulty card, a switch to a Y-Cable equipped redundant card occurs if available.
The back card for the BTM is available in two versions. One version supports a single ATM T3 port, and the other supports a single ATM E3 port. These back cards are the AIT-T3 and AIT-E3, respectively. The back card provides the interface to the trunk and performs all necessary CRC generation and checking. The trunk port consists of one BNC connector for transmit and one BNC connector for receive. The back card faceplate has six LED indicators. They indicate the status of the port and various alarm conditions (see Figure 2-19 and Table 2-12 for details).
The faceplate of the BTM has four LEDs. The ACTIVE LED indicates the card is active and functioning normally. A BTM card failure triggers the FAIL LED. The other two LEDs are a summary alarm for the AIT back card conditions. A yellow MINOR LED indicates either that a non service-interrupting error has occurred or error statistics have exceeded a preset threshold. A red MAJOR LED indicates a service-affecting failure.
The AIT -T3 back card has two BNC connectors and six LED indicators, as Figure 2-19 shows. Table 2-12 lists these faceplate items. When correlating the items in the figure and table, read from the top down.
Connector/Indicator | Function |
---|---|
Transmit Jack | BNC connector for transmit data |
Receive Jack | BNC connector for receive data |
LOS light (red) | Indicates loss of signal at the local end. |
Red Alarm light (red) | Indicates loss of local T3 or E3 frame alignment, or cell alignment. |
Yellow Alarm light (yellow) | Indicates loss of frame alignment at remote end, or cell alignment. |
AIS light (green) | Indicates the presence of all ones on the line. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE: light (green) | Indicates that the card is in service and that active circuits are present. |
The BTM card set supports Y-cable redundancy on ATM trunks in IGX to IGX, IGX to IPX and IGX to BPX applications. Y-Cable Redundancy is an existing IGX feature that may be applied to ATM trunks. (In the Command Reference, see commands addyred, delyred, dspyred, and ptyred.)
Y-Cable Redundancy requires that both cards are upped (uptrk) and added (addtrk) before assigning redundancy.
The BTM card performs a clock test on the input line source. If either the clock or card fails, a switch occurs to a Y-cabled redundant BTM trunk card set if available. If the switch occurs, the primary ATM trunk card acquires failed status, and the red FAIL indicator is turned on. If Y-cable redundancy is not available, the ATM trunk switches to another clock source and marks the line as a failed clock source.
2
The Channelized Voice Module (CVM8) is a dual-purpose front card that provides a method of terminating a T1, E1, or J1 circuit line (a communication line to CPE). The circuit line may carry either voice traffic alone, a combination of voice and low-speed or high-speed data, or just data. See Figure 2-20 . The channel default is voice mode until the interface type is reconfigured. The CVM8 data capabilities include DS0-A, 56/64 xN data rates. The CVM8 voice capabilities include A-law to µ-Law conversion and voice compression. These are configurable for each channel.
The CVM8 can be programmed for either 24-channel mode (T1) or 30-channel mode (E1). The circuits on a CVM8 hop are assigned on a per-timeslot basis within a T1 or E1 frame.
The CVM8 can reside in any front slot 3-8 in an IGX 8. The CVM8 operates with either a BC-T1, BC-E1, or BC-J1 back card. The back cards plug directly into the P2 connector on the front card. For details on the back cards, refer to "T1 Interface Card (BC-T1)," "E1 Interface Back Card (BC-E1)," and "BC-J1 Description " sections, which describe the BC-T1, BC-E1, or BC-J1, respectively.
The features of the CVM8 front card include:
Table 2-13 introduces the types of CVM8 circuit operation. (Sections that follow expand upon these subjects.) Two types of 64 Kbps clear channel operation are listed. The "p" indicates uncompressed PCM voice. The "t" indicates 64 Kbps clear channel data. Beyond these, different bit rates (with compression) and voice activity detection (voice connections only) are shown. A "c" or an "a" that precedes a numerical value indicates compression. The "c" indicates compression with VAD, and the "a" indicates compression without VAD. Therefore, "c" does not apply to data connections, and "a" can apply to either voice or data. The numerical value following the "a" or "c" is the bit rate. The table also defines the significance of the other characters that may follow the bit rate.
Type | Description |
---|---|
p | A p-type connection carries 64 Kbps PCM voice and supports A-law or µ-law encoding and conversion, level adjustment (gain/loss), and signalling. |
t | VF t-type connections carry 64 Kbps clear channel data traffics. |
cxx | When using the CVM8 card for voice circuits, the level of ADPCM compression must be specified by the x parameter and can be 32, 24, or 16 for 2:1, 3:1, or 4:1 compression. For example "c16" indicates full 4:1 compression with VAD. |
a16z | The c16z and a16z use a 4-level 16 Kbps ADPCM to ensure ones-density but at a decrease in voice quality. The "z" acts as a route-avoid specification whose effect is to avoid lines with ZCS (zero code suppression). |
a32d | The a32d and c32d circuit types pertain to Enhanced Instafax. These types support high speed circuits but stay at 32 Kbps when a high-speed circuit is detected and thus support compression that would otherwise be unavailable. Unless a32d or c32d is selected, the circuit switches to 64 Kbps when a high-speed modem or FAX is detected on a voice circuit. This selection is made using the cnfvchparm command. The selection of a32d or c32d depends on the performance of the modem/FAX using the circuit and should be selected for error-free operation. |
a32 a24 a16 | Uses ADPCM only. Can select 32 Kbps, 24 Kbps, or 16 Kbps compression. Compressed code avoids all zeros and can be used on lines with no other zero code suppression techniques. Modified 16 Kbps compression. |
c32 c24 c16 | Uses both ADPCM and VAD. Can select 32 Kbps, 24 Kbps, or 16 Kbps ADPCM compression. Compressed code avoids all zeros and can be used on lines with no other zero code suppression techniques. 16 Kbps compression is non-standard. |
Standard-rate (64 Kbps) voice connections originate and terminate on CVM8 T1 or E1 lines. The encoding type (A-law or µ-law), voice compression, and echo cancelling is configured on a per-channel basis according to the circuit requirements. The voice coding rate can be selected for 64 Kbps (no compression), 32 Kbps (2:1), 24 Kbps (2.67:1), or 16 Kbps (4:1). These compression ratios approximately double when the internal Voice Activity Detection (VAD) feature is also enabled.
The CVM8 extracts information from the signalling bits in the E1 or T1 frame and generates signalling packets when a signalling bit changes. These packets go from the local CVM8 to the far-end CVM8. DPNSS and ISDN signalling are supported through a clear channel (transparent mode). The signalling choices for the different configurations are:
Up to 23 voice interface types, such as 2-W E&M, FXO/FXS, DPO/DPS may be selected from a template to condition the VF signalling. Specifying any custom signal conditioning is also possible. Voice channel signalling can be programmed for any of the following:
Local and remote loopbacks are available for intranode, CVM8-terminated connections. Local loopback exists at the system bus interface and returns data and supervision back towards the local facility to test the local CVM8 card set and customer connection. Remote loopback connects to the CVM8 at the far end of the circuit and checks both directions of transmission and much of the remote CVM8.
The CVM8 faceplate has four LED indicators: ACTIVE, FAIL, MAJOR, and MINOR (see Table 2-14 ). The faceplate also shows the type of CVM8 card by way of the CVM8 label.
Indicator | Meaning |
---|---|
ACTIVE (green) | On indicates card is active and carrying traffic. |
FAIL (red) | On indicates self-test has detected a card failure in the main card or optional integrated echo canceller board. |
MAJOR (red) | A line failure has been detected locally on the receive side. |
MINOR (yellow) | A line failure has been detected at the remote end. |
Label CVM8 | Standard CVM8 |
CVM8 ADPCM T1 | T1 with echo cancelling module |
CVM8 ADPCM E1 | E1 with echo cancelling module |
The CVM8 monitors and reports statistics on the following input line conditions:
The CVM8, BC-T1, BC-E1, or BC-J1 support 1:1 redundancy by use of a second, identical, card set and a Y-cable connection to the circuit line. See Figure 2-21 for an illustration.
The CVM8 at each end of a connection is programmable for the two different voice encoding schemes. These encoding schemes are A-law and µ-law, and they operate at E1 and T1 rates, respectively. Thus, the CVM8 supports international gateway applications. The CVM8 supports high-speed modem and FAX circuits. The CVM8 provides transparent, 64 Kbps. transport for CCS signalling. It also supports CAS signalling by transporting signalling transitions across the network with negligible distortion. The CVM8 can set, invert, and clear AB or ABAB bits (T1) or ABCD bits (E1) to accommodate some signalling conversions.
Echo cancellers are almost always required on voice circuits to compensate for the delays introduced with the various voice compression techniques used by the CVM8. A built-in feature of the CVM8 is the on-board Integrated Echo Canceller (IEC). This eliminates having to provide this necessary feature with external equipment. Two models of the IEC are available: a 24-channel (T1) and a 31-channel (E1).
The CVM8 can provide data connections to the network. Data connections that originate on a CVM8 can terminate on either a CVM8, HDM, or LDM card on another node.
Data connections to the CVM8 fall into two categories: Superrate and Subrate. Superrate data connections are aggregates of channels that function as a single logical connection. These may be any multiple of 56 or 64 Kbps up to a maximum of 8 (512 Kbps). The DS0 timeslots must be contiguous or alternating, but they cannot be random. All 56 Kbps data channels are bit-stuffed up to 64 Kbps on circuit lines. The CVM8 removes the stuffing bits prior to packetization. A Superrate connection carries no supervisory bits.
In-band DS0A link codes are translated into EIA control lead states for CVM8-to-HDM or LDM connections, but fast EIA, DFM, and isochronous clocking are not available as with the HDM and LDM data cards.
The BC-J1 back card provides a Japanese J1 circuit line interface for a CVM8 card. The BC-J1 back card plugs directly into the P2 connector on the CVM8 front card. The card pair can be installed in any slot 3 to 8 in an IGX 8. The BC-J1 features the following:
Loop timing uses the receive clock from the network for the incoming data and turns the receive clock around for timing the transmit data.
Figure 2-22 shows a BC-J1 faceplate. Table 2-15 lists BC-J1 connections and status LEDs.
Connector/Indicator | Function |
---|---|
RX-TX | Female DB15 connector for XMT and RCV J1. |
Line in | J1 trunk input line |
Line out | J1 trunk output line |
RX MON | BNC test connector for monitoring receive J1 line. |
TX MON | BNC test connector for monitoring transmit J1 line. |
LOS light (red) | Indicates loss of signal at the local end. |
Red Alarm light (red) | Indicates loss of local frame alignment. |
Yellow Alarm light (yellow) | Indicates loss of frame alignment at remote end. |
AIS light (green) | Indicates the presence of all ones on the line. |
MFRA light (red) | Indicates loss of multiframe alignment |
MFYA light (yellow) | Indicates loss of multiframe at the remote end |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE light (green) | Indicates that the card is in service and that active circuits are present. |
Frame relay services on the IGX 8 require the FRM8 front card and one of four FRI back cards. The back cards plug directly into the P2 connector of the front card. Table 2-16 shows the FRM8 front cards and possible corresponding FRI back cards. The card pair can be installed in any of slots 3 to 8. These cards and software are optimized to accommodate the bursty nature of frame relay without dedicating excessive bandwidth to each circuit.
Front Card | Back Card | Model |
---|---|---|
FRM8Frame Relay Module | FRI-V.35 FRI-X.21 | B A |
FRM8-6Frame Relay Module, w/6 chan. | FRI-T1 or FRI-E1 | A |
FRM8-31Frame Relay Module, w/31 chan. | FRI-T1 or FRI-E1 | A |
The IGX 8 frame relay network features a Permanent Virtual Circuit (PVC) Service and a standards-based protocol Local Management Interface (LMI) for facilitating the administration and maintenance of the network. Two protocols are used: a data transfer protocol operates end-to-end through the network, and an LMI control protocol operates between the user device and the network. The frame relay cards can provide a frame-forwarding service in which all valid HDLC frames are forwarded from one port to a single specified port elsewhere in the network without frame relay header processing or LMI control. Frame relay service also provides bundled connections and explicit congestion notification.
The Frame Relay Module 8 (FRM8) front card is a programmable communications processor that can support one-to-four data ports and, in a single port mode, operate at speeds up to 2.048 Mbps. The FRM8 operates in conjunction with the appropriate FRI back card as a card set.
The FRM8 supports the following features.
The FRM8 can process a maximum of 252 virtual circuits (PVCs). The PVCs may be distributed over the four ports in any manner as long as the total of 252 PVCs and a limit of 2.048 Mbps per FRM8 card is not exceeded. Bundled and grouped connections are software groupings of multiple virtual circuits within a single routing connection. This allows a single node to support up to 1024 virtual circuits, equivalent to four FRM8s.
The FRM8 front card:
The FRM8 converts frame relay data into FastPackets while remaining transparent to the user data. Frame delimiting and transparency are provided by the HDLC flag bytes and bit stuffing. Valid hex 7E data bytes are converted using zero bit insertion such that they are not mistakenly taken as flag bytes.
On the receiving end, all frames are checked against the embedded Frame Check Sequence (FCS) code. A frame that does not pass is discarded. Flag bytes that are used to fill up any partially filled FastPacket frames are also discarded.
A hardware jumper position selects the clock for V.35 and X.21 interfaces. The clock is selected when the jumper position puts the back card in DTE mode. The FRM8 measures and reports the actual clock speed to the system software.
Three types of FRM8s are available. They are the FRM8, FRM8-6 and FRM8-31. The distinction between these three is as follows:
The Frame Relay Interface V.35 (FRI-V.35) is a four-port back card to the FRM8 card. Two models of the FRI-V.35 can support the FRM8:
The FRI-V.35 has the following functions and features:
Table 2-17 shows the relationship between the number of ports used on the FRI and maximum operating speed for each port. Model A FRM8 and FRI cards are included for early users who may not have updated the cards. Note that the port numbers start at the top on the FRI faceplate.
FRM8/FRI MODELS | PORT 1 | PORT 2 | PORT 3 | PORT 4 |
---|---|---|---|---|
A/A | £ 256 | £ 256 | £ 256 | £ 256 |
| 1024 | 0 | 0 | 0 |
B/A | £ 256 | £ 256 | £ 256 | £ 256 |
| £ 336 | £ 336 | £ 336 | 0 |
| £ 512 | £ 512 | 0 | 0 |
| 1024 | 0 | 0 | 0 |
C/A | £ 256 | £ 256 | £ 256 | £ 256 |
| £ 336 | £ 336 | £ 336 | 0 |
| £ 512 | £ 512 | 0 | 0 |
| 1024 | 0 | 0 | 0 |
C/B | One port can operate at 2048 or 1920. Combinations of ports can equal 2048 Kbps. If one port is 1920 or 2048, no other port may be active. |
Each frame relay port is assigned a number in the form:
where SLOT is the slot number where the FRM8/FRI-V.35 resides; PORT is the physical port in the range of 1-4; and DLCI is the identification number for the PVC. The range of valid DLCIs is 16-1007. DLCIs 0-15 and 1008-1023 are reserved.
The two clocking modes that the FRI supports are normal and looped (see Figure 2-24). Note that the direction for the clock and data are reversed for the two FRI mode configurations (DCE or DTE), as follows:
Implementing frame relay on a T1 or E1 line requires:
A Frame Relay T1/E1 connection can terminate on any Frame Relay InterfaceV.35, X.21, T1 or E1.
Frame Relay T1/E1 allows the user to group FRM8 DS0 timeslots into "logical ports." These logical ports are groups of contiguous DS0s or a single DS0. Logical ports that consist of multiple DS0s are at the full rate of 64 kbps per timeslot. Logical ports that consist of single DS0s may be configured as 56 Kbps or 64 Kbps. See Figure 2-25 .
Figure 2-26 illustrates the FRI-T1 and FRI-E1 back cards.
Port loopbacks (tstport and addextlp command) towards the IGX are not supported. Port loopbacks towards the facility are supported using the addloclp and addrmtlp command.
Except for LMI, logical ports do not support supervisory signalling. No EIA leads or signalling bits as used in a V.35 port. The commands cnfict, cpyict, dspict and prtict are ignored unless a FRI V.35 back card is present. The dspbob command is blocked when executed on a logical port.
Logical ports are created with the addfrport command, which associates a group of DS0s to a logical port number. The lowest timeslot number of the created group becomes the logical port number. The logical port number is used to up the port (upfrport), add connections (addcon) and display statistics (dspportstats).
Logical ports are displayed with the dspfrport command and are arranged in ascending port number sequence.
Logical ports are deleted using the delfrport command, which will ungroup any multiple DS0s and/or unassign a single DS0 logical port. (Connections for the ports must be deleted (delcon, delcons) prior to deleting the ports.) After deleting one or more ports, downing the port (dnfrport) can follow.
The FRI - X.21 is a back card used with the FRM8 front card to provide the X.21 interface to the IGX network. Each FRI connects directly to a corresponding FRM8 card.
Two different model D FRI cards are available: the FRI-V.35 and FRI-X.21. They differ only in the physical interface provided. The operating rates of each port and the composite data rate supported by the FRI-X.21 card are the same as the present frame relay V.35 card set. Each port may be configured either as a DCE or a DTE.
The FRI-X.21 uses leased line service for international networks. The V.35 version is for domestic US use and also is intended for connection to leased line service.
The FRI-X.21 back card has the following features:
The FRI can be configured to use any combination of one through all four ports. The configuration depends on the maximum operating speed required (the card itself has a maximum composite operating speed). The four ports are numbered from top to bottom on the FRI faceplate (Figure 2-27 ). Table 2-18 lists the available port operating speeds.
Any one port may operate at 2048 Kbps. Any combination of ports may equal 2048 Kbps. If one port is operating at 2048 Kbps, it must be port 1, and no other port may be active. The four DB15 port connectors numbered from top to bottom.
Port Speeds (Kbps) | Maximum |
---|---|
Any multiple of 56 Kbps | Up to 1.792 Mbps |
Any multiple of 64 Kbps | Up to 2.048 Mbps |
Table 2-19 lists the cable and pinouts used for X.21 ports.
Pin # | Name | Source | Description |
---|---|---|---|
1 | Gnd. | both | Protective (Shield) ground |
8 | Sig. Gnd. | both | Signal ground |
3/10 | C | both | Control |
5/12 | I | both | Indication |
2/9 | TxD | DTE | Transmit Data from DTE |
4/11 | RxD | DCE | Receive Data to DTE |
6/13 | S | DCE | Clock Out (DCE), Clock In (DTE) |
The FRI-X.21 supports only a normal clock mode. The direction of the clock and data lines is reversed if the FRI is configured as a DCE or as a DTE as follows (see Figure 2-28):
Optional redundancy for the frame relay card types (FRM8/FRI) can be provided with a second front and rear card set and a Y-cable connection on each port to the customer data equipment as illustrated in Figure 2-29. A card redundancy kit is available. The kit contains a second FRM8/FRI card set, a set of four Y-cables to interconnect the two card sets to the customer connection, and a redundant DCE/DTE programming board for the installed FRI. In the case of either a V.35 or X.21 interface, when a non-redundant card set is changed to a redundant card set, the DCE/DTE daughterboard on the FRI must be changed. Only the model D of the V.35 or X.21 back cards use the daughterboard.
Y cable redundancy is not possible between differing back card types, such as FRI T1/E1 to FRI V.35.
After the hardware is installed, the node must be reconfigured to indicate that the slot is equipped with redundancy. Use the Add Y Redundancy (addyred) command to do this. Refer to the Command Reference for more information on the redundancy commands addyred, delyred, dspyred, and ptyred.
As with all IGX cards, the FRI-X.21 includes internal diagnostic routines that periodically test the card's performance. These self-test diagnostics automatically start and run in background. They do not disrupt normal traffic. If a failure is detected during the self test, the faceplate red FAIL LED is turned on. The operator can also view the status at the control terminal by executing the Display Card (dspcd) command.
A report of a card failure remains until cleared. A card failure is cleared by the Reset Card (resetcd) command. The two types of reset that resetcd can do are hardware and failure. The failure reset clears the event log of any failure detected by the card self-test but does not disrupt operation of the card. A reset of the card firmware is done by specifying a hardware reset. This reboots the firmware and momentarily disables the card. If a redundant card is available, the hardware reset causes a switch over to the standby card.
The X.21 frame relay ports and any associated external modems, CSUs, or NTUs can be tested using data loopback points in the circuit path. There are three possible loopbacks for X.21 frame relay ports that may be established, as follows:
The modems must be compatible with the StrataCom loopback protocol. For information on supported modems and protocols, refer to the IGX 8 Installation Guide and the Command Reference for protocol requirements for the addextlp, addloclp, and addrmtlp commands. The ISC can also answer questions about modem protocol requirements.
All three loopbacks are set up using the tstport command. Only one port at a time can be in loopback mode for testing.
The internal loopback point is established inside the FRI card (see Figure 2-30). The FRM8 generates a test pattern, sends it out on the transmit circuitry, and detects this pattern on the receive circuitry. This test takes several seconds and momentarily interrupts traffic on the port. The test works on ports configured for either DCE or DTE.
For ports configured for DTE, the two additional tests (local loopback and remote loopback) are available. For these ports, two methods of loopback testing are available:
Replacing an FRI card is done the same way as other back cards. For these procedures, refer to the repair and replacement description in the IGX 8 Installation Guide.
This section introduces the Port Concentrator Shelf (PCS) for frame relay traffic. The PCS is an external device that expands the capacity of a Frame Relay Module (FRM8) to 44 low-speed ports. This ability to increase the port density of an IGX 8 switch supports more efficient usage for the common switch equipment. The port parameters are as follows:
The PCS requires a version of the FRM8/FRI card set that is exclusively dedicated to the PCS. The front card is the FRM8-2. The back card that interfaces the FRM8-2 to the PCS is the FRI-2-X.21. Figure 2-31 illustrates the relation ship between the FRM8/FRI card set and the PCS. It provides one or more X.21 links. Each X.21 link is called a concentrated link. In a full configuration, each concentrated link services one of four 11-port modules in the PCS. This makes a total of 44 ports on the FRM8-2.
For more detailed information on the PCS, refer to the section on the Port Concentrator Shelf in the System Manual. For detailed installation instructions, refer to the Port Concentrator Installation document that comes with each unit. Cabling information for the PCS appears in the cabling appendix in the IGX 8 Installation Guide and the Port Concentrator Installation document.
The following terms are used to identify PCS components:
The PCS operates within the IGX 8 environment as a frame relay card with 44 ports. Existing frame relay commands (cnffrport, upfrport, dnfrport, addcon, delcon, etc.) are the same in syntax and function. The difference is that a range of 44 ports can be specified instead of 4. The configuration of each of the PCS logical ports is similar to that of non-PCS frame relay ports. A frame relay card connected to a PCS notifies the system database and permits the additional ports to be specified.
The PCS requires the following:
Each of the four composite links between PCS and IGX 8 has a fixed configuration of:
The PCS Concentrated Link cable is illustrated in the cabling appendix. Its maximum length is 25 feet. The use of modems to extend this distance is not supported.
FRM8-2 firmware interacts with the PCS over composite links only if the FRM8-2 is active. The FRM8-2 changes from standby to active when its first logical port is activated.
A PCS logical port associated with an FRM8-2 card is activated with the upfrport command. The upfrport command requires the slot number of the FRM8-2 to which the PCS is connected. Enter the slot number and a logical port in the range of 1-44 (assuming a connection exists for all 4 composites between the PCS and IGX 8).
This example indicates that the FRM8-2 in slot 4 and concentrated link 1 are connected.
Entering the upfrport command for one port activates all four ports. The following events are generated by successful activation of four concentrated links. The display is from the example "upfrport 4.1:"
A noticeable delay occurs after upfrport begins executing on the first port. During initial upfrport execution, the FRM8-2 performs first-time configuration, diagnostic, and up/download functions.
If a concentrated link is not connected or fails to come up, the logical port remains in a failed state until either the link comes up or the port is deactivated with the dnfrport command.
When the frame relay ports are activated, the IGX 8 recognizes them as PCS-connected ports. Subsequently, all applicable frame relay port management commands accept logical port numbers in the form slot.port. The range for port is 1-44. Table 2-20 shows the logical ports the PCS supports. In Table 2-20 , slot is the IGX 8 slot in which the FRM8-2 resides.
PCS Ports | |
---|---|
Composite L1 | slot.1 to slot.11 |
Composite L2 | slot.12 to slot.22 |
Composite L3 | slot.23 to slot.33 |
Composite L4 | slot.34 to slot.44 |
The interface and clocking characteristics for each PCS port is independently configured to be V.11 (X.21), V.35, or V.28 by inserting the required interface card (or "ICARD") into the associated slot on the PCS module. For detailed information on PCS port hardware interfaces, refer to the Port Concentrator Installation document. This document comes in the PCS shipping container.
The IGX 8 does not have the capacity to read the type of interface present for the PCS port. Values entered under the Interface Type parameter with the cnffrport command are used in the display only and cannot be checked against the hardware.
A PCS is configured with the cnffrport command. With the following limitations, all parameters for the cnffrport command are supported:
1. For each group of 11 logical ports, the total speed must be 384 Kbps or less. The remaining 64 Kbps of composite link speed is reserved for control information. This total includes active ports only.
2. The default port speed is 38.4 Kbps (instead of 256 Kbps for non-PCS ports).
3. Speeds of 9.6, 14.4, 16, 19.2, 32, 38.4, and 48 Kbps are supported on PCS ports. Higher speeds (56 - 384 Kbps) are valid as long as limitation 1, above, is observed.
4. Only the active Interface Control Template is supported by the PCS.
All frame relay summary and interval statistics are kept for PCS ports.
The PCS and FRM8-2 share responsibility for statistics collection on PCS ports. The PCS maintain counters for:
All remaining statistics counters are collected by the FRM8-2. Although the IGX 8 supports ForeSight for PCS connections, CLLM (ForeSight) statistics are not available in Release 8.1. These fields are present but not valid.
Monitoring functions generally apply to the PCS with the exception that up to 44 ports may be specified per FRM8-2 slot. For descriptions of the monitoring commands, refer to the "Troubleshooting" chapter of the Command Reference. Note that commands dspchcnf, dspchstats, dspportstats, and dspbob fail when the required concentrated link is down. Trying to execute one of these commands on a concentrated link that is down causes an error message to appear.
The PCS measures the speed of receive data on logical ports if the port is configured as a DTE interface. To see the measured speed, use the dspbob command. The PCS measures port speed after any of the following occurs:
The process of measuring port speed sends out two 1-byte frames with no CRC on the port.
The IGX 8 measures the physical port speed for FRI-2-X.21 ports once per minute. The current measured speed is displayed with the dspfrcport command and should always read 512 Kbps when the port is active.
LED Name | Function |
---|---|
State | OFF = No power. RED = power applied but software not running. |
Rx | Flashes for frames received on concentrated link. With no activity on link, Link Rx blinks once per second. |
Tx | Flashes for frames transmitted on concentrated link With no activity on link, Link Tx blinks once per second. |
CPU A | On solid when operating software on CPU A is running. Should always be On during operation. |
CPU B | On solid when operating software on CPU B is running. Should always be On during operation. |
Port 1 | On for module connected to FRM8-2 Port 1. Should always be On for Module 1. |
Port 2 | On for module connected to FRM8-2 Port 2. Should always be On for Module 2. |
Port 3 | On for module connected to FRM8-2 Port 3. Should always be On for Module 3. |
Port 4 | On for module connected to FRM8-2 Port 4. Should always be On for Module 4. |
Download | Flashes when frames are received during software download from FRM-2. |
If the FRM8-2 or FRI-2.X21 card is removed for any reason, be sure to maintain card compatibility upon card replacement: the FRM8-2 card is compatible with only the FRI-2-X.21 back card. The IGX 8 declares a mismatch state for any other back card inserted into an active FRM8-2 slot. Inserting compatible hardware is the only way to clear the mismatch. Similarly, once an IGX 8 slot is active with an FRM8-2, a mismatch is declared if any other front card is inserted into this slot. Before the slot can be used for any other type of card, the slot must be de-activated as a PCS-capable frame relay card.
addcon | used to add frame relay connections. |
addloclp | test command for creating local loopback. |
addrmtlp | test command for creating remote loopback. |
cnfcondsc | configures frame relay connection description. |
cnfchpri | configures frame relay channel priority. |
cnfchutl | optimizes frame relay channel utilization. |
cnffrcls | configures frame relay class of service (also cnfcos command for connection). |
cnffrcon | configures frame relay connection parameters. |
cnffrport | configures frame relay port parameters. |
cnfpref | configures preferred route for frame relay connection. |
clrchstats | clears PCS frame relay channel statistics. |
clrfrcportstats | PCS-specific command for clearing FRI-2-X.21 physical port statistics. |
clrportstats | clears PCS frame relay port statistics. |
delcon | deletes a frame relay connection. |
delcongrp | deletes a frame relay connection group. |
dellp | deletes a frame relay loopback condition. |
dncon | deactivates a frame relay connection. |
dspchcnf | displays channel configuration. |
dspchstats | displays PCS frame relay channel statistics. |
dspfrcportstats | PCS-specific command to display FRI-2-X.21 physical port statistics. |
dspfrcbob | PCS-specific command for displaying FRI-2-X.21 physical port signals. |
dspfrport | displays PCS logical port. |
dspfrcport | displays FRI-2-X.21 physical port. |
dsppcs | PCS-specific command to display PCS unit information. |
dspportstats | displays PCS frame relay port statistics. |
dspcon | displays frame relay connections. |
prtcons | prints frame relay connections. |
prtchcnf | prints frame relay channel configuration. |
tstcon | tests frame relay connection. |
tstdelay | tests frame relay connection delay. |
tstpc | PCS-specific command to test the PCS. |
resetpc | PCS-specific command to reset the PCS. |
A PCS logical port failure is defined as a Minor alarm. The FTC/FRP Port Comm Failure icon appears in the dspalms screen. Any connection that terminates on a failed port is also failed. Three causes of a port failure are defined, as described under Alarms and Events.
A failed connection on a PCS logical port is conditioned in the same manner as a failed connection on a non-PCS FRP port. Only the active control template is supported on PCS ports. The "conditioned" control template should not be used for PCS logical ports.
When it detects a Port Concentrator on one of its links, the FRM8-2 checks for a compatible firmware revision on the Port Concentrator. If the FRM8-2 detects that the current firmware on the Port Concentrator is incompatible, the FRM8-2 downloads the current firmware to the Port Concentrator. This download operation takes about two minutes. An event is logged when a firmware download has either started or failed.
Operating software on the Port Concentrator is stored in Flash memory. Download should be required only if the PCS is connected to an FRM8-2 with newer firmware, or a PCS module is replaced and a software version difference exists.
The FRM8-2 card runs a self-test diagnostic when it is in the standby state. The system software uses a reserved channel on the FRM8-2 card to perform background loopback tests that include both the FRM8-2 and FRI-2-X.21. This test verifies that all components up to the FRI-2-X.21 physical port are functioning. These diagnostics do not test the PCS.
Information about PCS logical ports and frame relay connections is automatically reported to StrataView Plus, just as they are for FRP ports and connections.
Connection Management and other FRM8-2 port functions may also be handled for PCS ports from StrataView Plus.
The SNMP agent supports Port Concentrator logical ports. This includes configuring PCS port parameters, adding, or deleting frame relay connections, and retrieving statistics.
The SNMP agent also supports provisioning for 44 frame relay ports for FRM8-2; the existing MIB variables are extended to the expanded number of logical ports. SNMP management functions are not supported for the Port Concentrator concentrated links.
Interaction between the FRM8-2 and PCS automatically updates the database to display the number of connected logical FRM8-2 ports at the PCS. As a result, both the IGX 8 user interface and the StrataView Plus interface automatically display the additional capacity of 44 ports for the FRM8-2.
If, during normal operation, communication stops between FRM8-2 and PCS over a concentrated link, a concentrated link failure alarm is generated.
In addition, during startup, a concentrated link is failed for any of the following reasons:
The IGX 8 supports the use of FastPAD devices in the network. The cards that support FastPADs for an IGX are the FTM front card and an FPC back card. The back card provides either a T1, E1, V.35, or X.21 interface. Each FPC V.35 and FPC X.21 provides four ports, and each port can support one attached FastPAD device either locally or remotely via modem. The T1 card has a DB15 for RX/TX and an alternate pair of RX/TX BNC connectors. The E1 connections are the same except for additional RX/TX monitoring BNC connectors. Dual card sets configured for Y-cable redundancy are also supported. Figure 2-32 shows the FTM front card and the V.35 version of the FPC.
Commands entered at the control terminal manage the FTM/FPC, the FastPAD, and their ports and connections. Furthermore, statistics related to cards, ports, and the FastPAD are collected and made available to StrataView Plus.
Card management of the FTM/FPC card set includes detection of card installation and removal, card mismatch, and Y-cable redundancy.
Port management includes EIA signalling, LMI alarms, upping and downing of ports and the collection of port statistics available to StrataView Plus.
FastPAD management permits the management of cards and ports on the FastPAD device from the IGX 8 node. This management includes card and card removal detection, card mismatch, uploads and downloads between the FastPAD and the IGX 8 node.
Connection management involves mapping FastPAD connection to Frame Relay type VCs (virtual circuits). Connections originating at a FastPAD must terminate at another FastPAD. Each FTM/FPC card set supports up to 252 connections. VC statistics are collected and made available to StrataView Plus.
For descriptions of the FastPAD commands and detailed information on the FastPAD, refer to the FastPAD User's Guide. Refer also to the StrataView FastPAD User's Guide.
Data circuits are directly interfaced to the IGX 8 using the High-speed Data Module (HDM) or Low-speed Data Module (LDM) card sets. The HDM set consists of a HDM front card and a Synchronous Data Interface (SDI) back card. The LDM set consists of a LDM front card and a Low-speed Data Interface (LDI) back card. The back cards are used to match the circuit type to the front card. Synchronous data card sets are listed in Table 2-22. An IGX 8 can have up to 6 HDM/LDM sets in a non-redundant system, for support of up to 48 full-duplex data connections.
The synchronous data cards support the ability to configure and monitor EIA leads; the ability to configure each channel for clocking, data rate, and DTE or DCE interface type; and complete loopback testing capability. Data channels can support null modem emulation as well as constant-carrier and switched-carrier operation. Data interfaces are transparent with respect to protocol. Asynchronous, binary synchronous, and bit synchronous protocols are supported with no impact on host or terminal software.
Front Card | Back Card |
---|---|
HDM, High-speed Data Module | SDI, RS-449 synchronous data interface (for X.21 or RS-422). |
| SDI, V.35 synchronous data interface. |
| SDI, RS-232D synchronous data interface. |
| SDI, RS-232C synchronous data interface (for V.24). |
LDM, Low -speed Data Module | LDI, RS-232C (V.24) four-port and eight-port low-speed data interface, non-interleaved EIA. 4-port models limited to 56 Kbps., 8-port models up to 19.2 Kbps. |
| LDI, RS-232D four-port and 8-port, low-speed data interface, up to 19.2 Kbps., non-interleaved EIA. |
| LDI4/DDS, four-port AT&T 56 Kbps. Digital Data Service interface. |
The HDM front card in an IGX 8 is a programmable communications processor that can support one to four high speed, synchronous data channels. It operates at speeds from 1.2 Kbps up to 1.024 Mbps on all four ports while performing link error monitoring.
The HDM front data card:
An internal baud rate generator provides transmit and receive data clocks to the SDI card at the selected rate. The HDM can accept data from an external data device with a non network synchronized clock (isochronous clock) up to 112 Kbps. With isochronous clocking, the HDM sends a clock control signal to the other end of the circuit to synchronize the far end receive clock to the isochronous clock received at the near end.
Unless specified, a packet of data for EIA control lead information is built only at a very low rate or when a change of state is detected on one or more of the control leads. The data rate is specified as either "fast" or "not fast" (the default) by the addcon command for data connections. A fast EIA lead transmission can be specified in the software to send EIA control lead information in every FastPacket (interleaved EIA mode). This tightly couples the EIA lead states with the transmitted data but reduces the bandwidth efficiency.
The HDM card is installed in a front slot. An SDI back card plugs directly into the P2 connector of the front card. The SDI back card provides the proper data channel interface.
The HDM faceplate has message lights and push-buttons for monitoring and loopback control. The push-buttons relate to loopback testing and for scrolling through the FastPacket data ports for a snapshot of selected port conditions (indicated by PORT, PORT UNDER TEST, loopback, and communication line state lights). Figure 2-33 shows and Table 2-23 lists the controls and indicators. When correlating the figure and table, read them top-down.
Indicator | Function |
---|---|
PORT light (yellow) | Indicates which FastPacket data port on the back card is currently monitored. |
SCROLL push-button | When pressed toggles through to the desired port. Information that is displayed by the remaining lights on the HDM faceplate applies to the port whose corresponding light is on. |
LOOPBACK push-button | When pressed, toggles through the three loopback statesno loopback, local loopback, and remote loopbackon the port whose corresponding light is on. This button can be disabled by the cnffunc command. |
PORT UNDER TEST light | Indicates that one of the ports has been placed in the loopback mode. If this is not the current port, press the SCROLL push-button to toggle in the port being tested. |
LL light (yellow) | Indicates that one of the ports has a local loopback. |
RL light (yellow) | Indicates that a remote loopback is occurring on one of the ports. |
DTR light (green) | Indicates that the Data Terminal Ready signal is ON at the selected port terminal. |
TXD light (green) | Indicates that the Transmit Data signal is ON at the selected port terminal. |
DCD light (green) | Indicates that the Data Carrier Detect signal is ON at the selected port terminal. |
RXD light (green) | Indicates that the Receive Data signal is ON at the selected port. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE light (green) | Indicates that the card is active and functioning normally. |
Optional redundancy for HDM data card type can be provided by a second front and back card set and a Y-cable on each port to the customer data equipment. See Figure 2-34.
The SDI card is a synchronous data interface back card that connects to a front HDM card. Each SDI card has four connectors for its four data ports. Each port is independently configurable for DTE or DCE mode, baud rate, and so on. One-for-one port redundancy is provided with a second card set and standard Y-cable. In summary, the SDI card:
Four types of SDI back cards can provide an interface between an HDM front card and the customer data equipment. Table 2-24 distinguishes each type of SDI card.
Interface | No. of Ports | Connector Type |
---|---|---|
RS-232C/V.24 | 4-ports | DB25 Subminiature, female |
RS-232D/V.24 | 4-ports | DB25 Subminiature, female |
RS-449/X.21 | 4-ports | DB37 Subminiature, female |
V.35 | 4-ports | 34-pin MRAC type (Winchester), female |
Three clocking modes are available on the SDI for clocking in transmit data and clocking out receive data. In addition, the SDI can operate as either a DCE or DTE, which makes possible six combinations of clocking (See Figure 2-35 and Figure 2-36). With loop clocking, the user device must loop the RxC to the XTC for clocking out the transmit data.
When the SDI is configured as DTE, the user device is the source of clock timing and is generally not synchronous with the network (IGX) timing. This is isochronous clocking. Isochronous clocking allows the customer data sets at each end of a circuit to operate at slightly different rates (non-synchronously) with minimum delay and loss of data. This feature limits the amount of data allowed to accumulate in the HDM receive buffers and forces a re-synchronization before the delay reaches an unacceptable level.
Isochronous clocking is only acceptable for data rates of 112 Kbps or less and may be used only on one input at a time per port. It does not support two isochronous clock inputs in the same direction as would be required by some modems that output both the TxC and RxC clocks totally independently.
Split clocking mode uses the user device timing for timing data transmission in one direction and the IGX 8 timing for the other direction.
The LDM front card in an IGX 8 is a programmable communications processor that can support up to eight synchronous or asynchronous data ports. Each port is independently configurable for DTE or DCE mode, baud rate, and so on. The LDM card is a low speed data module for use on RS-232C ports with data rates up to 19.2 Kbps where the higher speed capabilities of an HDM are not required. An LDM data card, when used with a LDI4/DDS, can provide 56 Kbps Digital Data Service interfaces to the IGX.
The LDM can process either synchronous or non-synchronous data inputs. With non-synchronous inputs, the data is over sampled at a rate determined by how much data jitter the customer equipment can tolerate. Or the customer may elect to use an external device to convert the asynchronous data to synchronize before it is input to the IGX.
The LDM front data card:
Additional features such as embedded (fast) EIA, sixth EIA lead support, and pleisochronous clocking are also supported. The fast EIA control lead allows the user to specify including the RTS/CTS EIA control leads in the same FastPacket as customer data. The EIA control lead status is encoded as the eighth data bit in each data byte. This provides a quick EIA response without significantly affecting bandwidth requirements. It is limited to data rates of 19.2 Kbps and below.
The LDM can be installed in any empty front slot and requires an LDI back card. The LDI card plugs directly into the P2 connector of the LDM card.
The faceplate of the LDM has message lights and push-buttons for loopback control and signal monitoring. Figure 2-37 shows and Table 2-25 lists these indicators and buttons. When correlating the figure to the table, read from the top down. The buttons are for loopback testing and for scrolling through the FastPacket data ports to obtain a snapshot of selected data port conditions (indicated by PORT, PORT UNDER TEST, loopback, and communication line state lights).
Indicator | Function |
---|---|
PORT Readout Display | Indicates which FastPacket data port (1 through 8) on the Back card is currently under scrutiny. |
SCROLL push-button | When pressed, toggles through to the desired port. Information that is displayed by the remaining lights on the LDM faceplate applies to the port whose light is on. |
LOOPBACK push-button | When pressed, toggles through the three loopback states on the port whose light is on. The three states are: no loopback, local loopback, and remote loopback. |
PORT UNDER TEST light | Indicates that one of the ports has been placed in the loopback mode. If this is not the current port, press the SCROLL push-button to toggle in the port being tested. |
LL light (yellow) | Indicates that a local loopback is occurring on one of the ports. |
RL light (yellow) | Indicates a remote loopback is occurring on one a port. |
DTR light (green) | Indicates that the Data Terminal Ready signal is ON at the selected port terminal. |
TXD light (green) | Indicates that the Transmit Data signal is ON at the selected port terminal. |
DCD light (green) | Indicates that the Data Carrier Detect signal is ON at the selected port terminal. |
RXD light (green) | Indicates that the Receive Data signal is ON at the selected port. |
FAIL light (red) | Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE light (green) | Indicates that the card is active and functioning normally. |
Optional redundancy for LDM data card types can be provided with a second front and back data card set and a Y-cable connection on each port to the customer data equipment as indicated in Figure 2-38.
The 4-port and 8-port LDM supports only a subset of the full RS-232C/D control leads. The LDM supports only non-isochronous DCE normal and DCE or DTE looped clocking modes, transmission of 3 EIA lead states (non-interleaved), and baud rates of up to 19.2 Kbps on the 8-port version and 38.4 Kbps on the 4-port version. Split clock mode is not supported.
An LDI4/DDS card provides an interface for four 56 Kbps DDS circuits for T1 IGX 8 systems. The LDI4/DDS card can operate either as a Data Service Unit (DSU) or Office Channel Unit (OCU). Again, one for one port redundancy is available with a second card set and Y-cables for each port.
The LDI4/DDS operating parameters are software selectable for either DSU or OCU mode. Permissible operating speeds in Kbps are: 2.4, 4.8, 9.6, 19.2, and 56. The clock synchronization is looped clock for the OCU mode and external clock for the DSU mode. The LDI4/DDS supports the DDS control codes idle, zero suppression, out-of-service, and loopback sequences. Standard DDS diagnostic tools such as local and remote loopbacks are provided.
In the DSU mode, a port is connected to the local service provider and they should guarantee that the line length will not exceed the 34 dB loss limit that the DDS standard requires. When using a port in the OCU mode, private wiring is used. In this case, refer to Table 2-26 which shows worst case loss and maximum loop lengths for the different operating rates.
Line Rate | Loss | Equivalent Cable Length (miles) | |||
---|---|---|---|---|---|
(Kbps) | (dB) | 19 ga. | 22 ga. | 24 ga. | 26 ga. |
2.4 | 42 | 28.7 | 19.8 | 15.6 | 13.3 |
4.8 | 42 | 21.0 | 14.3 | 11.2 | 9.5 |
9.6 | 42 | 15.8 | 10.4 | 8.1 | 6.8 |
19.2 | 42 | 12.5 | 7.9 | 6.0 | 5.0 |
56 | 38 | 8.7 | 5.1 | 3.6 | 2.9 |
The Low-Speed Data Interface (LDI) card is a low-speed data interface back card that operates in conjunction with an LDM front card. The LDI provides the physical and electrical connection interface between the user low-speed data circuit and the LDM data PAD. Three models of the LDI exist. Two are four-port cards, and one is an eight-port card, as Table 2-27 indicates.
Some of the functions and features of the LDI are:
Unit | Interface | Ports | Connector Type |
---|---|---|---|
LDI 4 | RS-232C/D (V.24) | 4-ports | DB15 Subminiature, female |
LDI 8 | RS-232C/D (V.24) | 8-ports | DB15 Subminiature, female |
LDI 4 /DDS | DDS | 4-ports | DB15 Subminiature with pigtail adapter for 8-pin RJ-48 connections |
The LDI can operate either as a DCE or DTE. Selection is made by using a StrataCom DTE or DCE adapter cable between the port connector and the cable from the user device. This cable is terminated with a standard DB25 on the customer end. Each port is independently configurable for DTE or DCE mode.
Three EIA control leads are brought out to the rear connectors, three when used as a DCE and three for DTE. These leads are:
LDI as DCE | LDI as DTE |
---|---|
RTS | CTS |
DSR | DTR |
DCD | RL |
The RL lead allows the use of a previously unused DTE EIA output lead. Remote loopback (RL) may be used to enable a far-end modem loopback. Local loopback (LL) is not provided as an output on the LDI. If local loopback is required, use the DTR lead by wiring it to the connector pin for local loopback.
The LDI supports two clocking modes: normal and looped (Figure 2-39). The normal mode is used when the LDI port is configured as a DCE. Looped clock is only used when the LDI port is configured as a DTE. The user device must take the external transmit clock and loop it back to the RxC for clocking in the receive date. In both cases, the LDI is the source of clock timing. Table 2-29 shows the accuracy and worst case jitter that can be expected from an end-to-end circuit using LDIs at each end
Baud Rate | Accuracy (± Hz.) | Jitter (±%) |
---|---|---|
1200 | .06 | .03 |
2400 | .12 | .06 |
4800 | .24 | .12 |
9600 | .48 | .23 |
14,400 | .72 | .35 |
19,200 | .96 | .47 |
The alarm relay card set is optional. The set consists of an Alarm Relay Module (ARM) front card and an Alarm Relay Interface (ARI) back card. This card set provides alarm summary outputs by using relay contact closures.
The alarm outputs are typically wired to a telephone central office alarm system for remote alarm reporting to give an indication there is a problem in the associated equipment.
The alarm summary feature provided by the Alarm Relay cards provides both a faceplate visual indication of an IGX 8 node alarm as well as a set of relay outputs (dry-contact) for indicating node and network alarm indications. A visual alarm history indication is also provided. This alarm reporting is separate and is in addition to the alarm output at the node's control port, which provides a data output to a control terminal, e.g., the StrataView Plus Network Management Station. Table 2-30 summarizes the alarm conditions and the resulting indications.
One set of alarm relays is used to signal a major alarm or minor alarm on the node. One pair of contacts on each relay is used for audible alarms. These contacts are in series with a faceplate alarm cut-off (ACO) switch. The other set of relay contacts are used for visual alarms and are not affected by the ACO switch. When the ACO switch is activated, a faceplate ACO indicator lights up as a reminder to the operator. If the ACO switch is activated to disable the node's audible alarm output and a second alarm occurs, the audible alarm is re-activated. Two faceplate LEDs provide local indication of network alarms.
Alarm Category | Alarm Severity | Faceplate Indication | Relay Indication |
---|---|---|---|
Network | Major | none | Single form-C relay closed or open. |
| Minor | none | Single form-C relay closed or open. |
Node | Major | MAJOR LED (red) | Visual and audible relay closed only (normally open). |
| Minor | MINOR LED (yellow) | Visual and audible form-C relay closed or open. |
Alarm Cutoff | n.a. | ACO LED (green) | Interrupts audible relay closed. |
Alarm History | n.a. | HIST LED (green) | None. |
A second, independent, set of alarm outputs are provided to report network alarms. If a major or minor alarm occurs anywhere in the networknot necessarily on a particular nodethese alarm relays are activated.
Major alarm relays are normally energized, providing an open circuit, so that a complete power failure (relay de-energized) at the node will result in a contact closure and resulting major alarm output. Minor alarms, however, are normally de-energized to conserve power and both contact closures as well as contact openings are available for minor alarms.
When an alarm condition clears, the alarm relays return to their normal state to clear the alarm outputs. A faceplate history indicator is turned on for each node alarm occurrence. The indicator will remain on even though an alarm may have already cleared. The history indicator is manually cleared by pressing a faceplate switch.
Two additional relays may operate under software control to report any other condition. These are not currently used, but future releases of system software may define a use.
The ARM faceplate contains the alarm LEDs, ACO and History Clear push buttons, and the active and fail LEDs indicating the status of the ARM card (see Figure 2-40 and Table 2-31). The ARM card is used in conjunction with an ARI card. The ARI card connects to the ARM at the P2 connector. Relay drive signals originate in the ARM to operate relays on the ARI.
The ARM periodically runs a background self-test to determine the state of the card. If the card fails this self-test, the faceplate FAIL LED turns on, and the ACTIVE LED turns off.
Indicator | Function |
---|---|
MINOR LED (yellow) | Indicates a failure in the local node that is not service-affecting but still should be investigated. It could indicate problems such as a loss of redundancy, a low error rate on a digital trunk (frame bit errors or bipolar errors), etc. |
MAJOR LED (red) | Indicates a failure in the local node that is service-affecting, such as an IGX 8 card failure, that should be attended to immediately. |
ACO LED (white) | Indicates that a MINOR or MAJOR alarm is present, and that the alarm cutoff (ACO) button (5) was pressed to silence an accompanying audible alarm. The ACO light is turned off when the alarm condition is cleared. |
HISTory light (green) | Indicates that an alarm has occurred sometime in the past on the node. The alarm may be current or it may have cleared. Pressing the HIST CLR button (6) turns off this light if there is no current alarm. |
ACO button | When pressed, silences audible alarm (visual alarms remain on) and turns on ACO light (3). |
HIST CLR button | When pressed, turns off HIST light (4) if there is no current alarm. |
FAIL light (red) | Indicates that the card has failed self-test (an error occurred). Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC. |
ACTIVE light (green) | Indicates that the card is active, has been assigned using the addalmslot command, and is functioning normally. |
The installation of the ARM cards requires the removal of the node from service. The ARM can be physically installed in any front slot except slots normally reserved for the node processor cards (NPMs). The reserved slot numbers are 1 and 2. For standardization, StrataCom recommends that the ARM go in slot 8. The corresponding back slot must have an ARI card. The ARI card plugs directly in the ARM card.
Three commands are used with the ARM card set:
A female DB37 connector resides on the faceplate for connection to the customer's office alarm or alarm-reporting system. Refer to Figure 2-41 for an illustration of the ARI faceplate.
The following paragraphs describe the maintenance and troubleshooting features associated with the ARM card set. Preventive maintenance is not necessary.
As with all IGX 8 cards, the ARM has diagnostic routines that periodically run to test the card's performance. These self-test diagnostics are run in the background, so they do not disrupt normal traffic. If a failure is detected during the self test, the faceplate red FAIL LED is turned on. In addition, the status of the card can be checked at the control terminal by using the Display Card (dspcd) command.
If a card failure is reported, the report remains until cleared. A card failure is cleared by using the Reset Card (resetcd) command. Two types of resets are available. They are hardware and failure. The reset failure clears the event log of any failure detected by the card self test and does not disrupt card operation. The hardware reset reboots the firmware and resets the card, and this momentarily disables the card.
Replacing an ARM card is done the same way as other back cards. For these procedures, refer to the repair and replacement description in the IGX 8 Installation Guide.
At least one node in a network has a StrataView Plus terminal, a control terminal, or a dial-in modem connected to it. Any control terminal connected in the network can configure, manage, monitor, and diagnose the entire network. In addition, at least one node in a network may have a printer connected to it for printing error and event reports.
The control terminal and printer connect to two RS-232 serial ports. These ports are the Control Terminal and Auxiliary Port on the SCM faceplate. These serial ports support all standard asynchronous data rates from 1200 to 19,200 baud. The default rate is 9600 baud. Data rates and the type of equipment connected to the ports are software-configurable.
StrataCom recommends that at least one IGX 8 in the network connects to a direct-dial modem so that StrataCom ISC personnel can perform remote diagnostic tests. A direct-dial modem connects to the backplane at the Control Terminal port. In addition, an auto-dial modem can be connected to the AUX port connector on the SCM at any node in the network so that remote error messages and alarms can be sent to the ISC, where they are automatically logged.
An external clock source can be connected to the SCM card using the external clock adapter cable. The external clock device can be either 1.544 MHz or 2.048 MHz RS-422 square wave signals depending on the primary application of the IGX 8 (T1 or E1). Selection is made through software. The clock stability should be at least as good as a STRATUM 3 clock source. Appendix B lists the terminals, printers, modems and clock sources that have been tested and approved for use with the IGX.
Posted: Mon Sep 16 17:46:01 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.