This appendix contains system specifications.
This section provides general system information on the IGX 8. More detailed information on peripherals and cabling is available in the installation manual.
System Capacity: | 1 shelf with 8 card slots. |
Enclosure Size: | IGX 8 Standalone/Rackmount: |
Shipping Weight: | 270 pounds (122.7 kilograms) |
Clearance Requirement: | At least 30 inches front; nominal 30 inches rear clearance; |
Power Input Voltage: | AC system: 100 to 240 VAC (90-264 under-voltage and over-voltage tolerance), 47 to 63 Hz. |
Current Requirements: | Configuration dependentuse Network Design Tool for exact requirements. For planning purposes, use: |
♦ AC System | 10 A. Max. for 110 VAC, 5 A for 220 VAC. |
♦ DC System | 20 Amps max. at -48 VDC; 25 Amps at -42 VDC (worst case) |
Input AC Power | IEC 16 Amp input connector. Six different power cords are available to comply with the standards of different countries. Power cords are six feet (approximately two meters) long. |
DC Input Connections | 3-wire pluggable terminal block with screw terminal connectors. |
Operating Environment: | 0º to 50º C (32º to 104º F). Maximum 85% relative humidity |
Shock: | Withstands 10 G, 10 ms. at 1/2 sine wave. |
Vibration: | Withstands 1/4 G, 20-500 Hz. |
Heat Transfer to Room: | IGX 8: 2720 BTUs max. |
Voice Channel Interface: | 24-channel T1 (D4 format). |
Voice Compression | 32/24/16 Kbps ADPCM. |
Compression Algorithm: | ITU-T G.721, G.723, G.726. |
PCM Encoding Types: | Accommodates µ-Law or A-Law encoding, |
Channel Gain Control: | -8 dB to +6 dB. |
Signalling Modes: | T1: Robbed bit or CCS (ISDN). |
Signalling Conditioning: | Various make-busy and forced idle routines during circuit alarm can be specified on a per-channel basis. |
Quantizing Distortion Added: | 2.5 Quantizing Distortion Units (QDU)s with 32 Kbps ADPCM over 1 hop plus 0.7 QDUs with Digital Loss PAD (µ-law or A-Law). |
Sync. Data Interfaces: | RS-232C/D, RS-449/422, V.24, X.21, and V.35 |
High-Speed Data Rates (HDM): | 2.4 Kbps to 1.344 Mbps. |
Low-Speed Data Rates: | 2.4 to 19.2 Kbps per LDM port. |
Ports per card: | LDI: 4 or 8. |
Control Leads Supported: | SDI: Per interface standards. |
Control Lead Sync | Control leads are sampled every 50 ms. and changes will normally follow data within 100 to 1000 msec. Fast EIA lead will be within 1 byte. |
DS0A Interface: | Superrate, 56 Kbps to 512 Kbps (8 DS0s) per port. |
Data Clocking: | Synchronous and isochronous clocking. |
Pleisochronous | ± 2 percent of nominal data rate. |
Ports per card: | Four. |
Electrical Interface: | Digital Data System (DDS)AT&T Pub. 62310, November 1987. |
Interface Type: | DSU or OCU (software selectable). |
Data Rates: | 2.4, 4.8, 9.6, 19.2, and 56 Kbps (software selectable). |
DDS Data Encoding: | Standard DDS Bipolar Return to Zero. Alternate Mark Inversion coding with bipolar violation sequences for zero suppression and control. |
Data Compression: | Repetitive Pattern Suppression (RPS): 7, 8, or 16 bit pattern matching. |
Synchronization Modes: | External (DSU only) |
Control Codes Recognized: | Idle. |
Control Code Translation: | Translation of RTS to IDLE. |
Alarm Code Translation: | Translation of the logical NOR of Out-of-Service |
Connector: | ISO 4903, female DB-15 type connector. |
Line Rate: | 1.544 Mbps, ± 50 bps (± 200 bps VCO lock range). |
Line Code: | Bipolar AMI or B8ZS. |
Framing Formats: | Fractional T1, adjacent or alternating channels. |
Signal Level: | DSX-1 compatible. |
Line Impedance: | Terminated = 100 Ohms nominal. Bridged = 1 KOhm. |
Pulse Amplitude | Individual pulse amplitude 2.4 V-3.6 V (making a total base-to-peak amplitude of 6 V ± .6V) |
Minimum Pulse Density: | Zero code suppression, either LSB or MSB. |
Frame Format: | D4 and Extended Superframe (ESF). |
VF Signalling: | Robbed bit D4 with A and B bits. |
Max. Line Lengths: | Up to 533 feet with equalizers using ABAM cable. |
Jitter Transfer: | Meets AT&T PUB 62411 specifications. |
Jitter Tolerance: | Meets ANSI standards and AT&T PUB 62411 specs. |
Connector: | DB 15 female. |
Line Rate: | 2.048 Mbps, ± 50 bps (± 200 bps VCO lock range). |
Line Code: | Bipolar AMI or HDB3. |
Line Impedance: | 120 Ohms (balanced) or 75 Ohms (balanced or unbalanced) |
Minimum Pulse Density: | Zero code suppression via HDB3 coding. |
Frame Format: | Unframed, 32-channel (G.703). Framed: 30 or 31-channel CEPT multiframe per ITU-T G.704. |
VF Signalling: | CAS or CCS. |
Max. Line Lengths: | E1 output complies with G.703, so cabling must not exceed -6dB/1000 feet at 1024 kHz (applies to 75 Ohm coax or 120 Ohm twisted pair up to 350 meters or 1000 feet). StrataCom supplies cable with a maximum attenuation of 7 dB /1000 ft., so the maximum length of this cable is 850 feet (260 meters). |
Jitter: | Meets G.823. |
Electrical Interface: | Complies with G.703 Specification. |
Connector: | DB 15 female or BNC. |
Line Rate: | 44.736 Mbps ± 20 ppm, asynchronous. |
Line Code: | B3ZS. |
Clock Source Mode: | Internal (Asynchronous). |
Signal Level: | DSX-3. |
Framing Formats: | M13 mode, C-bit parity. |
Alarms Processed: | AIS. |
Line Errors Counted: | BPV. |
Receiver Input Impedance: | Terminated = 75 ohms. |
Transmission Modes: | Point-to-Point or Drop and Insert. |
Jitter: | Meets ACCUNET T45 specification (Pub 54014). |
Connector: | 75 ohm BNC. |
Max. Line Lengths: | 450 ft. (137 m.) to DSX-3 using 75 Ohm coaxial cable. |
Indicators: | RED Alarm. |
Line Rate: | 34.368 Mbps ± 20 ppm, asynchronous. |
Line Code: | HDB3. |
Clock Source Mode: | Internal (Asynchronous). |
Signal Level: | ITU-T G.703 |
Framing Formats: | ITU-T G.804, G.832, |
Alarms Processed: | AIS. |
Line Errors Counted: | BPV. |
Receiver Input Impedance: | 75 ohms unbalanced. |
Transmission Modes: | Point-to-Point or Drop and Insert. |
Jitter: | per ITU-T G.823. |
Connector: | 75 ohm BNC. |
Max. Line Lengths: | 137 meters (450 ft.) using specified cable. |
Indicators: | RED Alarm. |
Type of Service: | Permanent Virtual Circuit (PVC). |
Data Interface: | Per ITU-T I.122 and ANSI T1/S1 Standards. |
Data Transfer Protocol: | LAP-D frame level core functions. |
Input Data Format: | High Level Data Link (HDLC) protocol. |
Input Data Frame Length: | Up to 4096 bytes max. |
Frame Integrity Check: | Frame Check Sequence and CRC check of data frame. If CRC fails, data frame is discarded at receiving node. |
Input Data Rate: | 56 Kbps to 2.048 Mbps. (Max. rate available only with one of four ports/card active). |
No. of Ports per Card: | 4 |
No. of PVCs per Port: | 252 per FR card, distributed in any combination. |
Port Electrical Interface: | ITU-T V.35. IGX 8 can act as a DCE or DTE for direction of control leads and timing. |
Data Clocking: | Normal or looped. |
Virtual Circuit Identifier: | Data Link Connection Identifier (DLCI). |
Control Protocol: | Local Management Interface with XON/XOFF type flow control. IGX sets FECN and BECN bits in frame relay frame. |
Bundled Connections: | 252 virtual circuits per card |
Billing Time Accuracy: | Upon request from user device, IGX will provide GMT from any node accurate to within 1 second. |
Type of Service: | Permanent Virtual Circuit (PVC) |
Interface Types: | User-to-Network (UNI) and Network-to-Network (NNI) per ITU I.361 and I.363 |
Data Rates: | T3 or E3 |
ATM Layer: | Physical Layer Convergence Protocol per AT&T publication TA-TSY-00772 and 000773 for T3; ITU I-361 with HEC for E3 |
Cell Rate: | 96,000 cells/sec. for T3, 80,000 cells/sec. for E3 |
Adaptation Layer: | AAL5 |
No. of Ports per card: | 4 |
No. of PVCs per card: | 255 |
VPI Addressing Range: | 0-255 |
VCI Addressing Range: | 0-65535 |
Traffic Queues: | CBR, VBR, and ABR |
Management Protocol: | Interim Layer Management Interface (ILMI) |
External Clock Sources: | IGX 8 synchronizes to the nearest, highest-stratum clock available. Any E1 or T1 circuit line, trunk, or optional external clock input can be used as a clock source. |
Internal to Node Source: | T1: 1.544 MHz, ± 10 ppm. (Stratum 4). |
Clocking Hierarchy: | Dynamic primary, secondary, and tertiary clocking. |
Network Control Terminal: | StrataView Plus workstation and StrataCom software required for graphical display of network status, statistics gathering and display, and automatic downloading of software. |
Control Terminal: | DEC VT100, WYSE 85, Televideo 970 or equivalent terminal for basic system configuring and alarm monitoring. |
Remote Alarm Reporting: | Auto-dial modem connects to one of two control ports on each IGX 8 node for automatic reporting of network alarms. |
Remote Diagnostics: | Auto-answer modem connects to one of two control ports on each IGX node for remote diagnostic access by StrataCom ISC or other authorized personnel. |
Network Control Ports: | Two ports per node, (one RS 232C interface and one Ethernet LAN port). |
Alarm Notification: | Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus workstation at connecting node. |
External Alarms: | Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements when equipped with DTI group. |
Indicators and Controls: | Active and Fail lights on all cards and power supplies. |
Posted: Mon Sep 16 17:13:40 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.