Line Interface Cards

Line Interface Cards

This chapter describes the hardware and related functions for each circuit line card in the IGX. The description of each card includes:

A brief description of optional peripherals and third-party equipment appears at the end of the chapter. For system specifications, such as protocols and standards, refer to Appendix A.

For all matters relating to installation, troubleshooting, user-commands, and repair and replacement, refer to the IGX  Installation Manual.

Other manuals that relate to IGX operation are:

Circuit Line Card Groups

The IGX currently has the following circuit line card groups:

This chapter introduces each card in the preceding groups.

Card Types

Table 4-1 lists the front cards that can be used in the IGX. Table 4-2 lists the back cards that can operate in an IGX. In addition to the front and back cards, the IGX uses an Adapter Card Module (ACM). These cards attach to existing IPX 16/32 service module cards and perform the adaptation necessary to allow IPX 16/32 front cards to operate in an IGX 8, 16, or 32 system. Note that IPX 8-specific cards do not apply to the upgrade scheme. Beyond this, IPX back cards can operate in an IGX system without modifications.


Table 4-1: Front Cards
Card Acronym Card Name Model

CVM-ADPCM

Channelized Voice Module, ADPCM

A

CVM-T1

Channelized Voice Module, T1

A

CVM-E1

Channelized Voice Module, E1

A

UFM-4C

Universal Frame Module-Channelized (supports 4 lines on back card)

A

UFM-8C

Universal Frame Module-Channelized (supports 8 lines on back card)

A

FRM

Frame Relay Module (unchannelized), V.35/x.21 (with or without ACM)

B

FRM-2

Frame Relay Module, Port Concentrator only (with or without ACM)

A

FRM-31

Frame Relay Module, w/31 chan. (with or without ACM)

E

FTM

FastPAD Trunk Module (with or without ACM)

A

HDM

High-speed Serial Data Module

A

LDM

Low Speed Serial Data Module

A

ARM

Alarm Relay Module

A


Table 4-2:
Back Cards
Card Acronym Card Name Model

BC-E1

E1 Interface Card

A

BC-T1

T1 Interface Card

A

BC-Y1

Y1 Trunk Interface Card

A

BC-J1

J1 User (Circuit) Interface Card

A

BC-SR

Subrate Trunk Interface Card

A

UFI-8T1-DB15

Universal Frame Interface 8 T1 Card (With DB15 Connectors)

A

UFI-8E1-DB15

Universal Frame Interface 8 E1 Card (With DB15 Connectors)

A

UFI-8E1-BNC

Universal Frame Interface 8 E1 Card (With BNC Connectors)

A

FRI

Frame Relay Interface Card (V.35, T1/E1, X.21)

B

FPC

FastPAD Card (V.35, T1/E1, X.21)

B

SDI

Synchronous Data Interface:
RS-232C, RS-232D,
RS-422/449
X.21, V.24, and V.35

A

LDI

Low-Speed Data Interface
RS-232C/D, 4-port, 8-port
V.24, 4-Port, 8-Port
DDS, 4-port


A
A
A

ARI

Alarm Relay Interface

A

Common Alarms, Controls, and Indicators

Front cards and back cards have faceplates with indicator LEDs and, on some front cards, push-button controls. In addition, back card faceplates have the cable connectors. In slots where no back card exists, a blank faceplate must reside to contain Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI) and to ensure correct air flow.

The LED indicators are on the front and back card faceplates. Each plug-in card has both a green ACTIVE LED and a red FAIL LED at the bottom of the faceplate. In general, the meaning of each LED is indicated in Table 4-3. Some other cards have additional indicators, connectors, or controls, which the appropriate sections describe.


Table 4-3: Common Card Status Indicators
Indicators Status Meaning

FAIL

ON Steady

Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC.

FAIL

Blinking

On an NPM in a redundant system, this combination indicates that the card is being updated.

ACTIVE

ON steady

When steadily on, this combination indicates the card is active and carrying traffic or processing data.

ACTIVE

ON momentarily

When momentarily on, indicates the card executed a self-test.

BOTH

OFF

Indicates the card part of a redundant pair and is in the standby mode or not being used at all.

BOTH

ON

Indicates the card failed but remains active because no standby card is available. In the case of an HDM or LDM card, this could indicate that one or more of the data channels failed, but the others are still active.

Adapter Cards

StrataCom can upgrade IPX service/interface cards for use in an IGX. This allows the IGX to provide all the services of the IPX with cards of proven efficiency, functionality, and reliability. The upgrade is available only as a factory upgrade. The factory upgrade consists of an adding one of three possible Adapter Card Modules (ACM) and possible firmware or hardware modifications. Due to the complexity of the ACM, field upgrades of IPX cards are not possible.

Connecting IPX front cards to their corresponding back cards on the IPX requires the use of a utility or local bus. On upgraded IPX cards (IGX cards), the local or utility bus is not necessary.

The following IPX cards can be adapted for use in the IGX:

Channelized Voice Module (CVM)

This section introduces the Channelized Voice Module (CVM) and its related back cards. The subsections within this section are as follows:

For setup instructions, see the IGX Installation Manual and the relevant commands in the Command Reference.

The CVM is a multi-purpose front card. A CVM circuit line can carry the following types of traffic:

In addition to other CVMs, a CVM can communicate with a CDP in an IPX. The default mode for a channel on a CVM is voice. Figure 4-1 illustrates different traffic configurations. You can use the CVM in either 24-channel mode (T1) or 30-channel mode (E1). You assign the circuits on a CVM hop on a per-timeslot basis within a T1 or E1 frame.

The CVM resides in any non-reserved front slot in an IGX. It operates with either a BC-T1, BC-E1, or BC-J1 back card. The back card plugs into the P2 connector on the CVM front card. For details on the back cards, refer to the forthcoming sections titled "T1 Interface Back Card (BC-T1) ," "E1 Interface Back Card (BC-E1)," or "BC-J1 Description ."


Figure 4-1: CVM Application Diagram

CVM Features

The following is a list of CVM features.


Note For voice support specifications, refer to the appendix titled "System Specifications." For information on the application of the CVM card set to DNS, refer to the DNS Information and Operation manuals.

Modes of CVM Operation

This section describes the operational parameters you can specify for the CVM card set. Table 4-4 is a list of the types of CVM operation. The sections that follow further describe the listed subjects.

The first two entries in Table 4-4 are the two types of 64-Kbps, clear channel operation. The "p" indicates uncompressed PCM voice. The "t" indicates 64 Kbps clear channel data. The table then shows voice and data modes, transmit/receive rates, and indications of compression and ZCS (zero code suppression). A "c" or an "a" preceding a numerical value indicates compression. A "c" indicates compression with voice activity detection (VAD), so "c" does not apply to data connections. An "a" indicates compression without VAD. The "a" can apply to either voice or data. The numerical value following the "a" or "c" is the bit rate. Table 4-4 also explains the significance of the other characters that may follow the bit rate.

Standard-rate (64 Kbps) voice connections terminate on CVM T1 or E1 lines. You can configure the voice compression, and echo cancelling for each channel, and-when circumstances make it appropriate-A-law or µ-law encoding. You can select voice frequency compression of 64 Kbps (no compression), 32 Kbps (2:1), 24 Kbps (3:1), or 16 Kbps (4:1). The compression ratios approximately double when you also enable the internal VAD.


Table 4-4:
Types of CVM Connections

p

A p-type connection carries 64 Kbps PCM voice and supports A-law or µ-law encoding and conversion, gain adjustment, and signalling.

t

VF t-type connections carry 64 Kbps clear channel data traffic.

cxx

cxx signifies compression with VAD. When you use a CVM for voice and specify compression, you must specify the level of ADPCM compression by the xx field after the "c"." Enter 32 for 2:1 compression, 24 for 3:1 compression, or 16 for 4:1 compression. For example "c16" indicates 4:1 voice compression with VAD.

a16z
c16z

c16z and a16z use a 4-sample, 16-Kbps ADPCM that does not ensure ones-density. The "z" directs the node not to route a16z or c16z-type connections across ZCS-configured trunks.

a16
c16

c16 and a16 are non-standard forms of compression. They use a 4-sample, 16-Kbps ADPCM that ensures ones-density but results in a loss of voice quality. You can route a16 and c16-type connections across ZCS-configured trunks.

a32d
c32d

a32d and c32d provide compression for FAX on a high-speed line (such as Enhanced Instafax) without causing errors. Compression begins when the CDP/CVM detects a high speed modem. You must specify a32d or c32d with the cnfvchparm command. If you do not specify a32d or c32d, the circuit operates at the 56/64 Kbps when the CVM detects a high-speed modem or FAX. Note that, if you choose c32d (compression with VAD), it provides the bandwidth savings associated with VAD only when the line is actually carrying voice traffic.

a32
a24

Specifies ADPCM only. You can specify 32-Kbps or 24-Kbps.

c32
c24

Specifies both ADPCM and VAD. You can specify 32-Kbps or 24-Kbps.

CVM Voice Operation

The particular voice features are:

In addition to the preceding, the CVM can set, invert, and clear AB or ABAB bits (T1) or ABCD bits (E1) to accommodate some signalling conversions.

CVM Data Operation

A CVM can provide data connections to the network. Data connections that originate on a CVM can terminate on either a CVM, HDM, or LDM card set on another node.

Two categories of data connections exist on the CVM. The categories are super-rate and subrate. A super-rate connection is an aggregate of channels that functions as a single, logical connection. A super-rate connection can consist of any combination of 56 or 64 Kbps-connections up to a maximum of 8 connections totalling 512 Kbps. The DS0 timeslots must be contiguous or alternating (not random). All 56-Kbps data channels are bit-stuffed up to 64 Kbps on a circuit line. The CVM removes the bits prior to packetization. Note that super-rate connections carry no supervisory bits.

A subrate data connection has a rate less than 64 Kbps and exists within a DS0. The supported rates are 2.4, 4.8, 9.6, and 56 Kbps. The type of subrate data connection that StrataCom supports is DS0A.

In-band DS0A link codes are translated into EIA control lead states for CVM-to-HDM or LDM connections, but fast EIA, DFM, and isochronous clocking are not available.

Signalling on the CVM

The CVM extracts information from the signalling bits in the E1 or T1 frame. When a signalling bit changes state, the CVM generates signalling packets to the CVM at the other end of the connection. DPNSS and ISDN signalling are supported through a clear channel (transparent mode). The supported combinations of signalling and line configurations are as follows:

Up to 23 voice interface types, such as 2-W E&M, FXO/FXS, or DPO/DPS, can be selected from a template to condition the VF signalling. You can also specify customized signal conditioning. Voice channel signalling is programmable for any of the following:

Line Statistics

The CVM card set monitors and reports statistics on the following input line conditions:

Loopbacks on the CVM Card Set

You can set up local and remote loopbacks to check CVM-terminated connections. A local loopback functions at the system bus interface. It returns data and supervision back to the local facility to test the local CVM card set and the customer connection. Remote loopbacks extend to the CVM card at the other end and check both transmission directions and much of the far-end CVM.

CVM Faceplate Description

The CVM faceplate has four LED indicators: ACTIVE, FAIL, MAJOR, and MINOR (see Table 4-5). The label on the faceplate also shows the type of CVM card.


Table 4-5: CVM Faceplate Indicators

ACTIVE (green)

Indicates card is active.

FAIL (red)

Indicates self-test has detected a card failure in the main card or optional integrated echo canceller board.

MAJOR (red)

A line failure has been detected on the receive (local) side.

MINOR (yellow)

A line failure has been detected at the remote end.

CVM

A label indicating standard CVM

CVM ADPCM T1

A label indicating T1 with echo cancelling circuitry

CVM ADPCM E1

A label indicating E1 with echo cancelling circuitry

T1 Interface Back Card (BC-T1)

The BC-T1 back card provides a T1 circuit line interface for a CVM card. The BC-T1 plugs into the P2 connector on the CVM front card. The card set can reside in any non-reserved slot. The BC-T1 provides the following features:

B8ZS supports clear channel operation because B8ZS eliminates the possibility of a long string of 0s. B8ZS is preferable whenever available, especially on trunks.

The BC-T1 supports two clock modes. The clock modes are normal clocking and loop timing. You select the mode through software control. With normal clocking, the node uses the receive clock from the network for the incoming data and supplies the transmit clock for outgoing data. The node can use the receive clock to synchronize itself with the network.

With loop timing, the node uses the receive clock from the network for the incoming data and redirects this receive clock to time the transmit data.

BC-T1 Faceplate Description

Figure 4-2 and Table 4-6 provide information on the faceplate of the BC-T1. When you correlate the descriptions in the table with the callouts in the figure, read from the top of the table to the bottom. The standard port connector is a female DB15.


Figure 4-2: BC-T1 Faceplate

Table 4-6:
BC-T1 Connections and Status LEDs
Connector/Indicator Function

T1 INPUT/OUTPUT

Female DB15 connector for T1 line.

LOS light (red)

Indicates loss of signal at the local end.

Red alarm light (red)

Indicates loss of local E1 frame alignment, or it indicates loss of packet alignment on the CVM.

Yellow alarm light (yellow)

Indicates loss of frame alignment at remote end or loss of packet alignment (CVM).

AIS light (green)

Indicates the presence of all ones on the line.

FAIL light (red)

Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC.

ACTIVE: light (green)

Indicates the card is in service with active circuits.

E1 Interface Back Card (BC-E1)

The BC-E1 back card provides an E1 circuit line interface for a CVM card. The BC-E1 back card plugs into the P2 connector on the CVM front card. The card set can reside in any non-reserved slot. The BC-E1 provides the following features:

The BC-E1 supports two clock modes. The clock modes are normal clocking and loop timing. You select the mode through software control. With normal clocking, the node uses the receive clock from the network for the incoming data and supplies the transmit clock for outgoing data. The node can use the receive clock to synchronize itself with the network.

With loop timing, the node uses the receive clock from the network for the incoming data and redirects this receive clock to time the transmit data.

Statistics are kept on most line errors and fault conditions, including the following:

Figure 4-3 shows and Table 4-7 lists status LEDs and connections on the BC-E1 faceplate. When you correlate the table and figure items, read from the top to the bottom.


Figure 4-3: BC-E1 Faceplate

Table 4-7: BC-E1
Connections and Status LEDs

Connector/Indicator

Function

RX-TX

Female DB15 connector for XMT and RCV E1.

RX

BNC connector for receive E1 line.

TX

BNC connector for transmit E1 line.

LOS light (red)

Indicates loss of signal at the local end.

Red alarm light (red)

Indicates loss of local E1 frame alignment. On an CVM, Red alarm indicates loss of packet alignment.

Yellow alarm light (yellow)

Indicates loss of frame alignment at remote end. On an CVM, Yellow alarm indicates loss of packet alignment.

AIS light (green)

Indicates the presence of all ones on the line.

MFRA light (red)

Indicates loss of multiframe alignment (E1 only).

MFRY light (yellow)

Indicates loss of multiframe at remote end (E1 only).

FAIL light (red)

Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, StrataCom call the ISC.

ACTIVE: light (green)

Indicates the card is in service with active circuits.

BC-J1 Description

The BC-J1 back card provides a Japanese J1 circuit line interface for a CVM card. The BC-J1 back card plugs into the P2 connector on the CVM front card. The card set can reside in any non-reserved slot. The BC-J1 provides the following features:

The BC-J1 supports two clock modes. The modes are normal clocking and loop timing. You select the mode through software control. With normal clocking, the node uses the receive clock from the network for the incoming data and supplies the transmit clock for outgoing data. The node can use the receive clock to synchronize itself with the network. With loop timing, the node uses the receive clock from the network for incoming data and redirects the receive clock to time the transmit data.

Figure 4-4 shows a BC-J1 faceplate. Table 4-8 lists BC-J1 connections and status LEDs.


Figure 4-4: BC-J1 Faceplate
 

Table 4-8:
BC-J1 Connections and Status LEDs

RX-TX

Female DB15 connector for XMT and RCV J1.

Line in

J1 trunk input line

Line out

J1 trunk output line

RX MON

BNC test connector for monitoring receive J1 line.

TX MON

BNC test connector for monitoring transmit J1 line.

LOS light (red)

Indicates loss of signal at the local end.

Red alarm light (red)

Indicates loss of local frame alignment.

Yellow alarm light (yellow)

Indicates loss of frame alignment at the remote end.

AIS light (green)

Indicates the presence of all ones on the line.

MFRA light (red)

Indicates loss of multiframe alignment

MFYA light (yellow)

Indicates loss of multiframe at the remote end

FAIL light (red)

Indicates an error occurred. (First, reset the card with resetcd f. If the LED comes on again, call the StrataCom ISC.

ACTIVE light (green)

Indicates the card is in service and that circuits are active.

The TDM Transport Feature

This section applies only to CVMs (and CDPs in the IPX) that have Rev. C firmware. Rev. C provides a service called Time Division Multiplexing Transport (TDM Transport). TDM Transport bundles DS0s to form a single, transparent connection through the network. TDM Transport is most valuable for transporting TDM data from trunks in older, non-StrataCom WANs. For setup instructions, see the IGX Installation Manual and the relevant commands in the Command Reference.

Rev. C Features

The Rev. C firmware features are as follows:

Rev. C Limitations

The limitations on TDM Transport within Rev. C firmware are as follows:

Inverse Multiplexing

To achieve full T1 and E1 rates on a single CVM or CDP, TDM Transport supports inverse multiplexing. Figure 4-5 shows a simple example. In this example, the three, bundled 512-Kbps data connections symbolized by the arrows add up to a T1 connection.


Figure 4-5: Inverse Multiplexing

Achieving Optimal Performance for TDM Transport

Because a single bit error can cause the entire group of connections to lose synchronization temporarily, trunks and nodes that carry the traffic should have a low bit error rate. To minimize the recovery time after a loss of synchronization, configure the least possible number of connections to carry the bandwidth. In specifying a transparent T1, for example, 3 8x64 connections is much better than 24 1x64 connections.

Frame Relay Cards

This section describes the frame relay service cards. The frame relay cards consist of the UFM (Universal Frame Module) family of front and back cards and the FRM (Frame Relay Module) family of front and back cards. The first part of this section contains information that applies to UFM and FRM cards. Subsequent sections contain information that is particular to individual front and back cards. The frame relay and individual card topics are:

Refer to the IGX Installation Manual for installation instructions. For technical details on the line types that individual back cards support, refer to the appendix titled "System Specifications." For a description of the frame relay services that the FastPAD provides, refer to the section titled "FastPAD Trunk Module" later in this chapter.

Introduction

This section lists information that applies to frame relay service. The first list describes functions at the node-level and the network interface. The second list contains card-specific information.

An IGX frame relay network features the following:

The FRM and UFM front cards perform the following functions:

On the receiving end, the UFM, FRM, or FRM-2 card set checks arriving frames against the embedded Frame Check Sequence (FCS) code and discards any non-compliant frames. The frame relay card places frame relay data into FastPackets. Frame relay flag bytes and bit-stuffing provide frame delimiting and transparency. If a user data byte has a value of hexadecimal 7E, the frame relay card changes it by using 0-bit insertion, so that the card does not process the byte as a flag byte. (The frame relay card uses flag bytes to fill partial FastPackets.)

Frame Relay Over T1 and E1 Lines

On an IGX, frame relay over a T1 or E1 line requires:

A Frame Relay T1/E1 connection can terminate on any Frame Relay Interface—V.35, X.21, T1 or E1.

Frame relay over a T1 or E1 interface supports groups of DS0 timeslots in a logical port. A logical port is a single DS0 or a group of contiguous DS0s. Logical ports consisting of multiple DS0s operate at the full rate of 64 Kbps per timeslot. If a logical port consists of a single DS0, you can configure either 56 Kbps or 64 Kbps. See Figure 4-6.

If the rate on a logical port is 56 Kbps, the frame relay interface strips the least significant (signalling) bit from the incoming octet and puts a 1 in the least significant bit of the outgoing octet. The 56-Kbps rate typically applies to a groomed DDS circuit that uses a T1/E1 line.


Note E1 reserves timeslot 16 for special use, so timeslot 16 is unavailable with
channel-associated signalling (CAS). With common channel signalling (CCS), however, timeslot 16 carries data. See the cnfcln description in the Command Reference for information on how to specify the signalling.

Figure 4-6:
Multiple and Single DS0s Forming a Logical Port

Frame Relay Card Redundancy

Frame relay card redundancy can be provided through a second card set in adjacent slots and a Y-cable between each port that connects to the user-equipment. See Figure 4-7 for an illustration. The hardware kits for this feature contain a second frame relay card set, a set of Y-cables to interconnect the two card sets, and any other pieces that apply to the card types. Y-cable redundancy is not possible using back cards with different interfaces, such as an FRI T1 and FRI V.35.


Figure 4-7:
Frame Relay Port Redundancy

UFM Front Cards

The channelized Universal Frame Model (UFM-C) supports either 4 or 8 T1 or E1 lines per back card. The UFM-4C supports 4 lines regardless of the presence of the 8 lines on the UFI back card. The UFM-8C supports all 8 lines. Both models of the UFM-C support 1 to 24 or 1 to 31 DS0s per physical line.

The UFM-C can also operate unchannelized for E1 only, with 32 DS0s constituting one unchannelized E1. In the unchannelized mode, one logical E1 port maps to one E1 line.

Table 4-9 shows the front and back cards described in this and subsequent sections.


Table 4-9: Universal Frame Module Card Sets

UFM-4C
or

UFM-8C

UFI-8T1-DB15
UFI-8E1-DB15
UFI-8E1-BNC

The features and functions of the UFM-C are as follows:


Figure 4-8:
UFM Faceplate



Table 4-10:
UFM Faceplate Indicators

ACTIVE (green)

On indicates card is active.

FAIL (red)

On indicates self-test has detected a card failure.

MAJOR (red)

A line failure has been detected locally on one or more of the receive ports.

MINOR (yellow)

A line failure has been detected at the remote end on one or more of the receive ports.

UFI-8T1 Back Card

The Universal Frame Interface 8T1 (UFI-8T1-DB15) back card has 8, bi-directional, DB15 connectors. See Figure 4-9. For each port, one tri-color LED displays the status, as the emphasized area of Figure 4-9 shows. The line is inactive if the LED is off. See Table 4-11 .


Figure 4-9: UFI-8T1-DB15 Faceplate

Table 4-11:
UFI 8T1 Port LED Indicators

Green

On indicates line is active.

Red

On indicates line is active but a local alarm was detected.

Yellow

On indicates line is active but a remote alarm was detected.

UFI-8E1 Back Cards

Universal Frame Interface 8E1 cards have connectors for 8 E1 lines. The UFI-8E1-DB15 has 8 bi-directional DB15 connectors. The UFI-8E1-BNC has 16 BNC connectors (2 per line). See Figure 4-10. Each port has a tri-color LED for status display. See Table 4-12 . Note that the line is inactive if the LED is off.


Table 4-12: UFI 8E1 Faceplate Indicators

Green

On indicates line is active.

Red

On indicates line is active but a local alarm was detected.

Yellow

On indicates line is active but a remote alarm was detected.


Figure 4-10:
UFI-8E1-DB15 and UFI-8E1-BNC Faceplates

Frame Relay Module (FRM)

The Frame Relay Module (FRM) front card supports 1 to 4 data ports and, in single-port mode, operates at up to 2.048 Mbps.


Note FRM front cards exist in two forms. One uses an ACM1 adaptor. The other is a single-card or "native" version. Functionally they are identical. For the single-card version, the minimum firmware revision is "V."

Table 4-13: Frame Relay Module (FRM) Card Sets

FRM Frame Relay Module

D

FRI-V.35

FRI-X.21

B

A

FRM-6 Frame Relay Module, with 6 channels.

E

FRI-T1 or FRI-E1

A

FRM-31 Frame Relay Module, with 31 channels.

E

FRI-T1 or FRI-E1

A

FRM2 Frame Relay Module, Port Concentrator Shelf

F

FRI2-X.21

FRM Features and Functions

The FRM supports a maximum port speed of 2.048 Mbps plus the following features:

The FRM can support a maximum of 252 virtual circuits (PVCs). PVC distribution can cross all four ports if they do not exceed the 252 PVC limit and the limit of 2.048 Mbps per FRM.

Bundled and grouped connections are software groupings of multiple virtual circuits within a single routing connection. Grouping allows a node to support up to 1024 virtual circuits, which is the logical equivalent of four FRMs.

Frame Relay Interface (FRI) V.35 Card

The Frame Relay Interface V.35 (FRI-V.35) is a four-port back card to the FRM card. Two models of the FRI-V.35 can support the FRM:

The FRI-V.35 has the following functions and features:


Figure 4-11: Frame Relay V.35 Connectors and Indicator
s

Table 4-14 shows the relationship between the number of ports used on the FRI and maximum operating speed for each port. Model A FRM and FRI cards are included for early users who may not have updated the cards. Note that the port numbers start at the top on the FRI faceplate.


Table 4-14: Port Speed Combinations

A/A

£ 256

£ 256

£ 256

£ 256

1024

0

0

0

B/A

£ 256

£ 256

£ 256

£ 256

£ 336

£ 336

£ 336

0

£ 512

£ 512

0

0

1024

0

0

0

C/A

£ 256

£ 256

£ 256

£ 256

£ 336

£ 336

£ 336

0

£ 512

£ 512

0

0

1024

0

0

0

C/B
D/B

One port can operate at 2048 or 1920. Combinations of ports can add up to 2048 Kbps. If one port is 1920 or 2048, no other port can be active.

Frame Relay V.35 Port Numbering

Each frame relay logical channel has a number in the form:

  SLOT.PORT.DLCI

where

FRI-V.35 Data Clocking

The two clocking modes that the FRI supports are normal and looped. Figure 4-12 illustrates the two modes. Note that the direction for the clock and data is reversed for the two FRI mode configurations (DCE or DTE), as follows:


Figure 4-12:
Frame Relay Data Clocking Modes

Note Clock is looped by the FRI instead of the user device.

Figure 4-13 illustrates the FRI-T1 and FRI-E1 back cards.


Figure 4-13: Frame Relay T1/E1 Back Cards

Loopbacks

The IGX does not support port loopbacks (tstport and addextlp command) towards the IGX. In contrast, for V.35 and X.21 interfaces only, you can set up connection loopbacks towards the facility by using the addloclp and addrmtlp commands.

FRM-FRI Compatibility

The firmware on the front card must match the type of interface on the back card. Rev D firmware on the FRM supports X.21 and V.35 protocols. Rev E firmware on the FRM supports T1 and E1 protocols. The Display Card (dspcd) command indicates the type of back card that the FRM firmware supports and reports any mismatch.

Frame Relay Interface for X.21

The FRI-X.21 back card provides an X.21 interface to the user equipment. The two model D FRI cards are the FRI-V.35 and FRI-X.21. They differ only in the physical connectors (see Table 4-15). The operating rates of each port and the composite data rate supported by the FRI-X.21 card is the same as the FRI-V.35. You can configure each port as either a DCE or a DTE. Another FRI card is the FRI-2-X.21. This is the back card that provides the interface between the Port Concentrator Shelf (PCS) and the FRM-2. See the section titled "FRM-2 Interface to the Port Concentrator Shelf ."

The FRI-X.21 uses leased line service for international networks. The V.35 version is for domestic (U.S.) use and also uses a leased line service for its connections. The FRI-X.21 back card features:

FRI configuration supports one to four ports. The configuration depends on the maximum speed requirement (the card itself has a maximum composite speed). Figure 4-14 shows the FRI faceplate. Table 4-16 lists the available port operating speeds.

Any one port can operate at 2048 Kbps. Any combination of ports can equal 2048 Kbps. If a port is operating at 2048 Kbps, it must be port 1, and no other port can be active. Numbering of the 4 DB15 connectors starts at the top of the faceplate. Table 4-17 lists the cable and pinouts for an X.21 port.


Table 4-15: FRI Card Types

FRI-X.21

X.21

4-ports

DB15 Sub miniature, female

FRI-V.35

V.35

4-ports

34-pin MRAC type (Winchester), female


Table 4-16:
Frame Relay Port Speeds Available

Any multiple of 56 Kbps

Up to 1.792 Mbps

Any multiple of 64 Kbps

Up to 2.048 Mbps


Table 4-17:
FRI-X.21 Port Pin Assignments (DB 15-connector)

1

Gnd.

both

Protective (Shield) ground

8

Sig. Gnd.

both

Signal ground

3/10

C

both

Control

5/12

I

both

Indication

2/9

TxD

DTE

Transmit Data from DTE

4/11

RxD

DCE

Receive Data to DTE

6/13

S

DCE

Clock Out (DCE), Clock In (DTE)


Figure 4-14:
Frame Relay X.21 Connectors and Indicators

X.21 Data Clocking

The FRI-X.21 supports only normal clock mode. The direction of the clock and data lines is reversed if the FRI is configured as a DCE or as a DTE as follows (see Figure 4-15):


Figure 4-15:
Frame Relay Data Clocking Modes

Y-Cable Redundancy and Port Modes

The Y-cable redundancy kits for the FRI-X.21 and FRI-V.35 contain four extra daughter cards for specifying individual ports as either DCE or DTE. The extra daughter cards are 200-Ohm versions for the FRI already installed. The higher impedance cards are necessary because of circuit behavior at higher speeds when the two interfaces are in parallel (by way of the Y-cable).

Card Self Test

As with all IGX cards, the FRI-X.21 includes internal diagnostic routines that periodically test the card's performance. These self-test diagnostics automatically start and run in background. They do not disrupt normal traffic. If a failure is detected during the self test, the faceplate red FAIL LED is turned on. The operator can also view the status at the control terminal by executing the Display Card (dspcd) command.

A report of a card failure remains until cleared. A card failure is cleared by the Reset Card (resetcd) command. The two types of reset that resetcd can do are hardware and failure. The failure reset clears the event log of any failure detected by the card self-test but does not disrupt operation of the card. A reset of the card firmware is done by specifying a hardware reset. This reboots the firmware and momentarily disables the card. If a redundant card is available, the hardware reset causes a switch over to the standby card.

Port Testing (X.21)

The X.21 frame relay ports and any associated external modems, CSUs, or NTUs can be tested using data loopback points in the circuit path. The three possible loopbacks for X.21 frame relay ports are:

The modems must be compatible with the StrataCom loopback protocol. For information on supported modems and protocols, refer to the appendix titled "Peripherals Specifications" in the IGX Installation Manual. Also, refer to the Command Reference for protocol requirements for the addextlp, addloclp, and addrmtlp commands. For information that applies to loopbacks on the FRM-2/FRI-2 and PCS, see the descriptions of these loopback commands in the Command Reference. If these sources fail to clarify a particular situation, contact Cisco Customer Service.

All three loopbacks are set up using the tstport command. Only one port at a time can be in loopback mode for testing.

The internal loopback point is established inside the FRI card. Figure 4-16 illustrates the setup. The FRM generates a test pattern, sends it out on the transmit circuitry, and detects this pattern on the receive circuitry. This test takes several seconds and momentarily interrupts traffic on the port. The test runs on a port that is in either DCE or DTE mode.


Figure 4-16: Frame Relay Loopback Modes

For ports configured for DTE, the two additional tests (local loopback and remote loopback) are available. For these ports there are two methods of loopback testing:

Unit Replacement

FRI card replacement is the same as other back card replacement. For back card replacement procedures, refer to the IGX Installation Manual.

FRM-2 Interface to the Port Concentrator Shelf

This section introduces the Port Concentrator Shelf (PCS) for frame relay traffic. The PCS is an external device that expands the capacity of a Frame Relay Module (FRM) to 44 low-speed ports. This ability to increase the port density of an IGX switch supports more efficient usage for the common switch equipment. The port parameters are as follows:

The PCS requires a version of the FRM/FRI card set that is exclusively dedicated to the PCS. The front card is the FRM-2. The back card that interfaces the FRM-2 to the PCS is the FRI-2-X.21. Figure 4-17 illustrates the relation ship between the FRM/FRI card set and the PCS. It provides one or more X.21 links. Each X.21 link is called a concentrated link. In a full configuration, each concentrated link services one of four 11-port modules in the PCS. This makes a total of 44 ports on the FRM-2.


Note FRM-2 front cards exist in two forms. One uses an ACM1 adaptor. The other is a single-card or "native" version. Functionally they are identical, and the firmware is the same.

For more detailed information on the PCS, refer to the section on the Port Concentrator Shelf in the System Manual. For detailed installation instructions, refer to the Port Concentrator Installation document that comes with each unit. Cabling information for the PCS appears in the cabling appendix and in the Port Concentrator Installation document.


Figure 4-17:
Port Concentrator Shelf Components

Terminology

The following terms are used to identify PCS components:

Operation and User Interface

Other than front panel LEDs, the PCS has no user interface because the PCS functions as an extension of the FRM-2. PCS ports are operated and maintained from the IGX user interface.

The PCS operates within the IGX environment as a frame relay card with 44 ports. Existing frame relay commands (cnffrport, upfrport, dnfrport, addcon, delcon, etc.) are the same in syntax and function. The difference is that a range of 44 ports can be specified instead of 4. The configuration of each of the PCS logical ports is similar to that of non-PCS frame relay ports. A frame relay card connected to a PCS notifies the system database and permits the additional ports to be specified.

PCS-to-IGX Interface

Compatibility

The PCS requires the following:


Note Use of the PCS with the FRM-2 is exclusive: the PCS does not work with any other model of the FRM, and only a PCS works with the FRM-2. For example, if fewer than four PCS modules are used, unused frame relay ports cannot connect to something other than the PCS.

Concentrated Link

The concentrated link refers to the connection between port concentrator and frame relay card. Each module supporting 11 external ports is connected to 1 of the 4 ports on the FRI-2-X.21 back card.

Configuration

Each of the four composite links between PCS and IGX has a fixed configuration of:

The PCS Concentrated Link cable is illustrated in the cabling appendix. Its maximum length is 25 feet. You cannot use a modem to extend this distance.

Activation

FRM-2 firmware interacts with the PCS over composite links only if the FRM-2 is active. The FRM-2 changes from standby to active state when its first logical port is activated.

upfrport Command

A PCS logical port associated with an FRM-2 card is activated with the upfrport command. The upfrport command requires the slot number of the FRM-2 to which the PCS is connected. Enter the slot number and a logical port in the range of 1-44 (assuming a connection exists for all 4 composites between the PCS and IGX).

  Example: upfrport 4.1

This example indicates that the FRM-2 in slot 4 and concentrated link 1 are connected.

Entering the upfrport command for one port activates all four ports. The following events are generated by successful activation of four concentrated links. The display is from the example "upfrport 4.1:"

  "Info FRM 4 Activated"
"Info FRM Port 4.1 Activated
"Info FRM Concentrated Link 4.1 Failure Cleared"
"Info FRM Concentrated Link 4.2 Failure Cleared"
"Info FRM Concentrated Link 4.3 Failure Cleared"
"Info FRM Concentrated Link 4.4 Failure Cleared"

A noticeable delay occurs after upfrport begins executing on the first port. During initial upfrport execution, the FRM-2 performs first-time configuration, diagnostic, and up/download functions.

If a concentrated link is not connected or fails to come up, the logical port remains in a failed state until either the link comes up or the port is deactivated with the dnfrport command.

De-activation: the dnfrport Command

The FRM-2 card set returns to the standby state after you de-activate all 44 logical ports by executing the dnfrport command.

PCS Port Configuration

When the frame relay ports are activated, the IGX recognizes them as PCS-connected ports. Subsequently, all applicable frame relay port management commands accept logical port numbers in the form slot.port. The range for port is 1 to 44. Table 4-18 shows the logical ports the PCS supports. In Table 4-18 , slot is the IGX slot in which the FRM-2 resides.


Table 4-18: PCS Logical Ports

PCS Ports

Composite L1

slot.1—slot.11

Composite L2

slot.12—slot.22

Composite L3

slot.23—slot.33

Composite L4

slot.34—slot.44

Interface Hardware Configuration

The interface and clocking characteristics for each PCS port is independently configured to be V.11 (X.21), V.35, or V.28 by inserting the required interface card (or "ICARD") into the associated slot in the PCS. For detailed information on PCS hardware interfaces, refer to the Port Concentrator Installation document. This document comes in the PCS shipping container.

The IGX does not have the capacity to read the type of interface present for the PCS port. The values you enter under Interface Type with the cnffrport command appear in the display only and cannot be checked against the hardware.

The cnffrport Command

You configure a PCS with the cnffrport command. With the following limitations, all parameters for the cnffrport command are supported:

    1. For each group of 11 logical ports, the total speed must be 384 Kbps or less. The remaining 64 Kbps of composite link speed is reserved for control information. This total consists of only active ports.

    2. The default port speed is 38.4 Kbps (instead of 256 Kbps for non-PCS ports).

    3. Each PCS logical port supports speeds of 9.6, 14.4, 16, 19.2, 32, 38.4, or 48 Kbps. Higher speeds (56 to 384 Kbps) are valid as long as your configuration stays within limitation 1, above.

    4. Only the active Interface Control Template is supported by the PCS.

Port Statistics

All frame relay summary and interval statistics are kept for PCS ports. The PCS and FRM-2 share responsibility for statistics collection on PCS ports. The PCS maintain counters for:

All remaining statistics counters are collected by the FRM-2. Although the IGX supports ForeSight for PCS connections, CLLM (ForeSight) statistics are not available in Release 8.1. These fields are present but not valid.

PCS Monitoring Functions

Monitoring functions generally apply to the PCS except that you can specify up to 44 logical ports for a FRM-2 slot. For descriptions of the monitoring commands, refer to the "Troubleshooting" chapter of the Command Reference. Note that commands dspchcnf, dspchstats, dspportstats, and dspbob fail when the required concentrated link is down. Trying to execute one of these commands on a concentrated link that is down causes an error message to appear.

Collecting the Monitoring Information

Logical Port Speed

The PCS measures the speed of receive data on logical ports if the port is configured as a DTE interface. To see the measured speed, use the dspbob command. The PCS measures port speed after any of the following occurs:

The process of measuring port speed sends out two 1-byte frames with no CRC on the port.

Physical Port Speed

The IGX measures the physical port speed for FRI-2-X.21 ports once per minute. The current measured speed is displayed with the dspfrcport command and should always read 512 Kbps when the port is active.

PCS Front Panel LEDs


Table 4-19: PCS Module Front Panel LEDs

LED Name

Function

State

OFF = No power. RED = power applied but software not running.
GREEN = Operating software running.

Rx

Flashes for frames received on concentrated link.

With no activity on link, Link Rx blinks once per second.
With steady activity on link, Link Rx is on continuously.

Tx

Flashes for frames transmitted on concentrated link

With no activity on link, Link Tx blinks once per second.
With steady activity on link, Link Tx is on continuously.

CPU A

On solid when operating software on CPU A is running. Should always be On during operation.

CPU B

On solid when operating software on CPU B is running. Should always be On during operation.

Port 1

On for module connected to FRM-2 Port 1. Should always be On for Module 1.

Port 2

On for module connected to FRM-2 Port 2. Should always be On for Module 2.

Port 3

On for module connected to FRM-2 Port 3. Should always be On for Module 3.

Port 4

On for module connected to FRM-2 Port 4. Should always be On for Module 4.

Download

Flashes when frames are received during software download from FRM-2.

Card Insertion and Removal

If the FRM-2 or FRI-2.X21 card is removed for any reason, be sure to maintain card compatibility upon card replacement: the FRM-2 card is compatible with only the FRI-2-X.21 back card. The IGX declares a mismatch state for any other back card inserted into an active FRM-2 slot. Inserting compatible hardware is the only way to clear the mismatch. Similarly, once an IGX slot is active with an FRM-2, a mismatch is declared if any other front card is inserted into this slot. Before the slot can be used for any other type of card, the slot must be de-activated as a PCS-capable frame relay card.

PCS Command Summary

The commands in the list that follows apply to PCS frame relay ports. Most commands have the syntax described in the Command Reference with the exception that system software recognizes 44 ports per FRM-2 instead of 4. Some commands are PCS-specific.

addcon

used to add frame relay connections.

addloclp

test command for creating local loopback.

addrmtlp

test command for creating remote loopback.

cnfcondsc

configures frame relay connection description.

cnfchpri

configures frame relay channel priority.

cnfchutl

optimizes frame relay channel utilization.

cnffrcls

configures frame relay class of service (also cnfcos command for connection)

cnffrcon

configures frame relay connection parameters.

cnffrcport

configures the concentrated link between the FRM-2 cards and the PCS.

cnffrport

configures frame relay port parameters.

cnfpref

configures preferred route for frame relay connection.

clrchstats

clears PCS frame relay channel statistics.

clrfrcportstats

PCS-specific command for clearing FRI-2-X.21 physical port statistics.

clrportstats

clears PCS frame relay port statistics.

delcon

deletes a frame relay connection.

delcongrp

deletes a frame relay connection group.

dellp

deletes a frame relay loopback condition.

dncon

deactivates a frame relay connection.

dspchcnf

displays channel configuration.

dspchstats

displays PCS frame relay channel statistics.

dspfrcportstats

PCS-specific command to display FRI-2-X.21 physical port statistics.

dspfrcbob

PCS-specific command for displaying FRI-2-X.21 physical port signals.

dspfrport

displays PCS logical port.

dspfrcport

displays FRI-2-X.21 physical port.

dsppcs

PCS-specific command to display PCS unit information.

dspportstats

displays PCS frame relay port statistics.

dspcon

displays frame relay connections.

prtcons

prints frame relay connections.

prtchcnf

prints frame relay channel configuration.

tstcon

tests frame relay connection.

tstdelay

tests frame relay connection delay.

tstpc

PCS-specific command to test the PCS.

resetpc

PCS-specific command to reset the PCS.

PCS Port Failures

A PCS logical port failure is defined as a minor alarm. The FTC/FRP Port Comm Failure icon appears in the dspalms screen. Any connection that terminates on a failed port is also failed. Three causes of a port failure are defined, as described under Alarms and Events.

Conditioning

A failed connection on a PCS logical port is conditioned in the same manner as a failed connection on a non-PCS FRP port. Only the active control template is supported on PCS ports. The "conditioned" control template should not be used for PCS logical ports.

PCS General Operation

Firmware Download

When it detects a Port Concentrator on one of its links, the FRM-2 checks for a compatible firmware revision on the Port Concentrator. If the FRM8-2 detects that the firmware on the Port Concentrator is incompatible, the FRM8-2 downloads the current firmware to the Port Concentrator. This download operation takes about two minutes. An event is logged when a firmware download has either started or failed.

Operating software on the Port Concentrator is stored in Flash memory. Download should be required only if the PCS is connected to an FRM-2 with newer firmware or a PCS module is replaced and a software version difference exists.

Automatic Diagnostics—FRM-2 and FRI-2-X.21 Cards

The FRM-2 card runs a self-test diagnostic when it is in the standby state. The system software uses a reserved channel on the FRM-2 card to perform background loopback tests that include both the FRM-2 and FRI-2-X.21. This test verifies that all components up to the FRI-2-X.21 physical port are functioning. These diagnostics do not test the PCS.

StrataView Plus Interface

Information about PCS logical ports and frame relay connections is automatically reported to StrataView Plus, just as they are for FRP ports and connections.

Connection Management and other FRM-2 port functions may also be handled for PCS ports from StrataView Plus.

SNMP Manager

The SNMP agent supports Port Concentrator logical ports. This includes configuring PCS port parameters, adding, or deleting frame relay connections, and retrieving statistics.

The SNMP agent also supports provisioning for 44 frame relay ports for FRM-2; the existing MIB variables are extended to the expanded number of logical ports. SNMP management functions are not supported for the Port Concentrator concentrated links.

User Interface

Interaction between the FRM-2 and PCS automatically updates the database to display the number of connected logical FRM-2 ports at the PCS. As a result, both the IGX user interface and the StrataView Plus interface automatically display the additional capacity of 44 ports for the FRM-2.

Concentrated Link Failure

If, during normal operation, communication stops between FRM-2 and PCS over a concentrated link, a concentrated link failure alarm is generated.

In addition, during start-up, a concentrated link is failed for any of the following reasons:

FastPAD Trunk Module

The IGX supports FastPAD devices. The interface cards for FastPADs are the FTM front card and FPC back card. The back card provides either a T1, E1, V.35, or X.21 interface. Each FPC V.35 and FPC X.21 provides four ports. Each port can support one FastPAD either locally or remotely (via modem). The T1 card has a DB15 for RX/TX and an alternate pair of RX/TX BNC connectors. The E1 connections are the same except for additional RX/TX-monitoring BNC connectors. Y-cable redundancy is also supported. Figure 4-18 shows the FTM front card and the FPC-V.35.


Note FTM front cards exist in two forms. One uses an ACM1 adaptor. The other is a single-card or "native" version. Functionally, they are identical and use the same firmware.

Commands you enter manage the FTM/FPC, the FastPAD, and their ports and connections. Statistics that relate to cards, ports, and the FastPAD are collected for StrataView Plus. Card management of the FTM/FPC card set includes detection of when you install or remove a card, accidentally mis-match back cards, or set up Y-cable redundancy.


Figure 4-18: FastPAD Cards: FTM and FPC (V.35)

Port management includes EIA signalling, LMI alarms, upping and downing of ports and the collection of port statistics available to StrataView Plus.

FastPAD management permits the management of cards and ports on the FastPAD device from the IGX. This management includes card and card removal detection, card mismatch, uploads and downloads between the FastPAD and the IGX node.

Connection management involves mapping FastPAD connection to Frame Relay-type virtual circuits (VCs). Connections that originate at a FastPAD must terminate at another FastPAD. Each FTM/FPC card set supports up to 252 connections. The card set collects statistics on these connections and provides them to StrataView Plus.

For descriptions of the FastPAD commands and detailed information on the FastPAD, refer to the FastPAD User's Guide. Refer also to the StrataView FastPAD User's Guide.

Data Cards

A data circuit has a direct interface to the IGX through either a High-speed Data Module (HDM) or Low-speed Data Module (LDM) card set. The HDM set consists of an HDM front card and a Synchronous Data Interface (SDI) back card. The LDM set consists of an LDM front card and a Low-speed Data Interface (LDI) back card. The back cards match the circuit type to the front card. Synchronous data card sets are listed in Table 4-20. An IGX 32 node can have up to 25 HDM/LDM sets in a non-redundant system, for support of up to 200 full-duplex data connections.

The synchronous data cards support the ability to configure and monitor EIA leads; the ability to configure each channel for clocking, data rate, and DTE or DCE interface type; and complete loopback testing capability. Data channels can support null modem emulation as well as constant-carrier and switched-carrier operation. Data interfaces are transparent with respect to protocol. Asynchronous, binary synchronous, and bit synchronous protocols are supported with no impact on host or terminal software.


Table 4-20: Synchronous Data Cards Available

HDM, High-speed Data Module

SDI, RS-449 synchronous data interface (for X.21 or RS-422).

SDI, V.35 synchronous data interface.

SDI, RS-232D synchronous data interface.

SDI, RS-232C synchronous data interface (for V.24).

LDM, Low -speed Data Module

LDI, RS-232C (V.24) four-port and eight-port low-speed data interface, non-interleaved EIA. 4-port models limited to 56 Kbps., 8-port models up to 19.2 Kbps.

LDI, RS-232D four-port and 8-port, low-speed data interface, up to 19.2 Kbps., non-interleaved EIA.

LDI4/DDS, four-port AT&T 56 Kbps. Digital Data Service interface.

High-speed Data Module (HDM)

The HDM front card in an IGX is a programmable communications processor that can support one to four high speed, synchronous data channels. It operates at speeds from 1.2 Kbps up to 1344 Kbps on all four ports while performing link error monitoring.

The HDM front data card:

An internal baud rate generator provides transmit and receive data clocks to the SDI card at the selected rate. The HDM can accept data from an external data device with a non network synchronized clock (isochronous clock) up to 112 Kbps. With isochronous clocking, the HDM sends a clock control signal to the other end of the circuit to synchronize the far end HDM receive clock to the isochronous clock received at the near end.

Unless specified, a packet of data for EIA control lead information is built only at a very low rate or when a change of state is detected on one or more of the control leads. The data rate is specified as either "fast" or "not fast" (the default) by the addcon command for data connections. A fast EIA lead transmission can be specified in the software to send EIA control lead information in every FastPacket (interleaved EIA mode). This tightly couples the EIA lead states with the transmitted data but reduces the bandwidth efficiency.

The HDM card is installed in a front slot. An SDI back card plugs directly into the P2 connector of the front card. The SDI back card provides the proper data channel interface.

The faceplate of the HDM has message lights and buttons for loopback control and signal monitoring. The buttons relate to loopback testing or scrolling through the FastPacket data ports for a snapshot of selected data port conditions (indicated by PORT, PORT UNDER TEST, loopback, and communication line state lights). Figure 4-19 illustrates and Table 4-21 lists the controls and indicators. When correlating the figure to the table, read from the top down.


Figure 4-19: HDM Controls and Indicators

Table 4-21:
HDM Controls and Indicators

PORT light (yellow)

Indicates which data port on the back card is currently monitored.

SCROLL push-button

When pressed toggles through to the desired port. Information that is displayed by the remaining lights on the HDM faceplate applies to the port whose corresponding light is on.

LOOPBACK push-button

When pressed, toggles through the three loopback states—no loopback, local loopback, and remote loopback—on the port whose corresponding light is on. This button can be disabled by the cnffunc command.

PORT UNDER TEST light
(yellow)

Indicates one of the ports has gone into loopback mode. If this is not the current port, press the SCROLL button to toggle in the port being tested.

LL light (yellow)

Indicates a local loopback is present on a port.

RL light (yellow)

Indicates a remote loopback is present on a port.

DTR light (green)

Indicates the Data Terminal Ready signal is ON at the selected port terminal.

TXD light (green)

Indicates that the Transmit Data signal is ON at the selected port terminal.

DCD light (green)

Indicates the Data Carrier Detect signal is ON at the selected port terminal.

RXD light (green)

Indicates that the Receive Data signal is ON at the selected port.

FAIL light (red)

Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC.

ACTIVE light (green)

Indicates that the card is active and functioning normally.

Redundancy for HDM data cards can be provided with a second front and back card set and a Y-cable connection on each port to the customer equipment. See Figure 4-20.


Figure 4-20: HDM Data Port Redundancy

Synchronous Data Interface Card (SDI)

The SDI card is a synchronous data interface back card that directly connects to a front HDM card. Each SDI card has four connectors and provides the physical and electrical connection interface to four data ports. Each port is independently configurable for DTE or DCE mode, baud rate, and so on. One for one port redundancy is provided with a second card set and a standard Y-cable arrangement.

The SDI card:

Four types of SDI back cards can provide an interface between an HDM front card and the customer data equipment. Table 4-22 distinguishes each type of SDI card.


Table 4-22: SDI Physical Interfaces

RS-232C/V.24

4-ports

DB25 Subminiature, female

RS-232D/V.24

4-ports

DB25 Subminiature, female

RS-449/X.21

4-ports

DB37 Subminiature, female

V.35

4-ports

34-pin MRAC type (Winchester), female

Three clocking modes are available on the SDI for clocking in transmit data and clocking out receive data. In addition, the SDI can operate as either a DCE or DTE, which makes possible six combinations of clocking. (See Figure 4-21 and Figure 4-22 .) With loop clocking, the user device must loop the RxC to the XTC for clocking out the transmit data.

When the SDI is configured as DTE, the user device is the source of clock timing and is generally not synchronous with the network (IGX) timing. This is isochronous clocking. Isochronous clocking allows the customer data sets at each end of a circuit to operate at slightly different rates (non-synchronously) with minimum delay and loss of data. This feature limits the amount of data allowed to accumulate in the HDM receive buffers and forces a re-synchronization before the delay reaches an unacceptable level.


Figure 4-21: Clocking Modes for SDI in DCE Mode

Figure 4-22:
Clocking Modes for SDI in DTE Mode

Isochronous clocking involves a mechanism that lets a node at the far end compensate for an unstable clock in the user device at the near end. Data transmission in an isochronous network is reliable up to 112 Kbps. You can use isochronous clocking on only one input at a time per port. The SDI does not support two isochronous clock inputs in the same direction as required by some modems that generate the TxC and RxC clocks independent of each other.


Note The IGX automatically uses isochronous mode when the DTE/DCE endpoints justify it.

Split clocking uses the user-device timing for timing data transmission in one direction and the IGX timing for the other direction.

Low Speed Data Module (LDM)

The LDM front card supports up to 8 synchronous or asynchronous data ports. Each port is independently configurable for DTE or DCE mode, baud rate, and so on. The LDM card is a low speed data module for use on RS-232C ports with data rates up to 19.2 Kbps, where the higher speed capabilities of an HDM are unnecessary. An LDM can provide 56 Kbps Digital Data Service interfaces to the IGX when it operates with an LDI4/DDS.

The LDM can process either synchronous or non-synchronous input data. With non-synchronous inputs, the data is over-sampled at a rate determined by how much jitter your equipment can tolerate. Using an external device is also possible for synchronizing the asynchronous data before the data enters the IGX.

The LDM front data card:

Additional features, such as embedded (fast) EIA, sixth EIA lead support, and pleisochronous clocking, are also supported. The fast EIA control lead lets the user include the RTS/CTS EIA control leads in the same FastPacket as customer data. The EIA control lead status is encoded as the eighth data bit in each data byte. This provides a quick EIA response without significantly affecting bandwidth requirements. It is limited to data rates of 19.2 Kbps and below.

The LDM can reside in any empty front slot and requires an LDI back card. The LDI card plugs directly into the P2 connector of the LDM card.

The faceplate of the LDM has message lights and buttons for loopback control and signal monitoring. Figure 4-23 shows and Table 4-23 lists these indicators and buttons. When correlating the figure to the table, read from the top down. The buttons are for loopback testing and scrolling through the FastPacket data ports to obtain a snapshot of selected port conditions (indicated by PORT, PORT UNDER TEST, loopback, and communication line status lights).


Figure 4-23: LDM Connections and Indicators

Table 4-23:
LDM Connections and Indicators

PORT Readout Display

Indicates which FastPacket data port (1 through 8) on the Back card is currently under scrutiny.

SCROLL push-button

When pressed, toggles through to the desired port. Information that is displayed by the remaining lights on the LDM faceplate applies to the port whose light is on.

LOOPBACK push-button

When pressed, toggles through the three loopback states on the port whose light is on. These states are: no loopback, local loopback, remote loopback.

PORT UNDER TEST light
(yellow)

Indicates that a port has gone into the loopback mode. If this is not the current port, push the SCROLL button to toggle in the port being tested.

LL light (yellow)

Indicates that a local loopback is occurring on one of the ports.

RL light (yellow)

Indicates a remote loopback is occurring on one a port.

DTR light (green)

Indicates the Data Terminal Ready signal is ON at the selected port terminal.

TXD light (green)

Indicates the Transmit Data signal is ON at the selected port terminal.

DCD light (green)

Indicates the Data Carrier Detect signal is ON at the selected port terminal.

RXD light (green)

Indicates that the Receive Data signal is ON at the selected port.

FAIL light (red)

Indicates an error occurred. Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC.

ACTIVE light (green)

Indicates that the card is active and functioning normally.

Redundancy for LDM data card types is available through a second front and back card set and a Y-cable connection on each port to the customer data equipment. Figure 4-24 illustrates redundancy.


Figure 4-24: LDM Data Port Redundancy

The 4-port and 8-port LDM supports only a subset of the full RS-232C/D control leads. The LDM supports only non-isochronous DCE normal and DCE or DTE looped clocking modes, transmission of 3 EIA lead states (non-interleaved), and baud rates of up to 19.2 Kbps on the 8-port version and 38.4 Kbps on the 4-port version. Split clock mode is not supported.

DDS Using the LDM/LDI

An LDI4/DDS card provides an interface for four 56 Kbps DDS circuits for T1 IGX systems. The LDI4/DDS card can operate either as a Data Service Unit (DSU) or Office Channel Unit (OCU). Again, one for one port redundancy is available with a second card set and Y-cables for each port.

The LDI4/DDS operating parameters are software selectable for either DSU or OCU mode. Permissible operating speeds in Kbps are: 2.4, 4.8, 9.6, 19.2, and 56. The clock synchronization is looped clock for the OCU mode and external clock for the DSU mode. The LDI4/DDS supports the DDS control codes idle, zero suppression, out-of-service, and loopback sequences. Standard DDS diagnostic tools such as local and remote loopbacks are provided.

In the DSU mode, a port is connected to the local service provider and they should guarantee that the line length will not exceed the 34 dB loss limit that the DDS standard requires. When using a port in the OCU mode, private wiring is used. In this case, refer to Table 4-24 which shows worst case loss and maximum loop lengths for the different operating rates.


Table 4-24: DDS Loop Length Maximums
(Kbps) (dB) 19 ga. 22 ga. 24 ga. 26 ga.

2.4

42

28.7

19.8

15.6

13.3

4.8

42

21.0

14.3

11.2

9.5

9.6

42

15.8

10.4

8.1

6.8

19.2

42

12.5

7.9

6.0

5.0

56

38

8.7

5.1

3.6

2.9

Low Speed Data Interface Card (LDI)

The Low-Speed Data Interface (LDI) card is a low-speed data interface back card that operates in conjunction with an LDM front card. The LDI provides the physical and electrical connection interface between the user low-speed data circuit and the LDM data PAD. Three models of the LDI exist. Two are four-port cards, and one is an eight-port card, as Table 4-25 indicates.

Some of the functions and features of the LDI are:


Table 4-25: LDI Physical Interfaces

LDI 4

RS-232C/D (V.24)

4-ports

DB15 Subminiature, female

LDI 8

RS-232C/D (V.24)

8-ports

DB15 Subminiature, female

LDI 4 /DDS

DDS

4-ports

DB15 Subminiature with pigtail adapter for 8-pin RJ-48 connections

The LDI can operate either as a DCE or DTE. Selection is made by using a StrataCom DTE or DCE adapter cable between the port connector and the cable from the user device. This cable is terminated with a standard DB25 on the customer end. Each port is configured separately.

Three EIA control leads are brought out to the rear connectors, three when used as a DCE and three for DTE. These leads are:


Table 4-26:
EIA Control Leads

RTS

CTS

DSR

DTR

DCD

RL

The RL lead allows the use of a previously unused DTE EIA output lead. You can use remote loopback (RL) to enable a far-end modem loopback. Local loopback (LL) is not provided as an output on the LDI. If local loopback is required, use the DTR lead by wiring it to the connector pin for local loopback.

The LDI supports two clocking modes: normal and looped (Figure 4-25). The normal mode is used when the LDI port is configured as a DCE. Looped clock is only used when the LDI port is configured as a DTE. The user device must take the external transmit clock and loop it back to the RxC for clocking in the receive-data. In both cases, the LDI is the source of clock timing. Table 4-27 shows the accuracy and worst case jitter that can be expected from an end-to-end circuit using LDIs at each end.


Table 4-27: LDI Clocking Accuracy and Jitter Performance

1200

.06

.03

2400

.12

.06

4800

.24

.12

9600

.48

.23

14,400

.72

.35

19,200

.96

.47


Figure 4-25:
LDI Clocking Modes

Optional Alarm Interface Cards

The alarm relay card set is optional. The set consists of an Alarm Relay Module (ARM) front card and an Alarm Relay Interface (ARI) back card. This card set provides alarm summary outputs by using relay contact closures.

The alarm outputs are typically wired to a telephone central office alarm system for remote alarm reporting to give an indication there is a problem in the associated equipment.

The alarm summary feature provided by the Alarm Relay cards provides both a faceplate visual indication of an IGX node alarm as well as a set of relay outputs (dry-contact) for indicating node and network alarm indications. A visual alarm history indication is also provided. This alarm reporting is separate and is in addition to the alarm output at the node's control port, which provides a data output to a control terminal, such as the StrataView Plus Network Management Station. Table 4-28 summarizes the alarm conditions and the resulting indications.

One set of alarm relays is used to signal a major alarm or minor alarm on the node. One pair of contacts on each relay is used for audible alarms. These contacts are in series with a faceplate alarm cut-off (ACO) switch. The other set of relay contacts are used for visual alarms and are not affected by the ACO switch. When the ACO switch is activated, a faceplate ACO indicator lights up as a reminder to the operator. If the ACO switch is activated to disable the node's audible alarm output and a second alarm occurs, the audible alarm is re-activated. Two faceplate LEDs provide local indication of network alarms.


Table 4-28: ARM Card Set Alarm Reporting

Network

Major

none

Single form-C relay closed or open.

Minor

none

Single form-C relay closed or open.

Node

Major

MAJOR LED (red)

Visual and audible relay closed only (normally open).

Minor

MINOR LED (yellow)

Visual and audible form-C relay closed or open.

Alarm cutoff

n.a.

ACO LED (green)

Interrupts audible relay closed.

Alarm history

n.a.

HIST LED (green)

None.

A second, independent, set of alarm outputs are provided to report network alarms. If a major or minor alarm occurs anywhere in the network—not necessarily on a particular node—these alarm relays are activated.

Major alarm relays are normally energized, providing an open circuit, so that a complete power failure (relay de-energized) at the node will result in a contact closure and resulting major alarm output. Minor alarms, however, are normally de-energized to conserve power and both contact closures as well as contact openings are available for minor alarms.

When an alarm condition clears, the alarm relays return to their normal state to clear the alarm outputs. A faceplate history indicator is turned on for each node alarm occurrence. The indicator will remain on even though an alarm may have already cleared. The history indicator is manually cleared by pressing a faceplate switch.

Two additional relays are available under software control to report other conditions, but these relays are currently unassigned.

The alarm reporting feature requires a card set that includes an ARM front card and an ARI back card. This card set can reside in any slot except the reserved slots. However, StrataCom recommends that the front card go in the slot on the far right. Since a failure of either of these cards does not affect service, card redundancy is not necessary.

Alarm Relay Module (ARM)

The alarm relays are controlled by system software through Control Bus commands. The ARM interface with the Control Bus allows the card to receive alarm signals from the NPM and to send status signals back to the NPM. The firmware on the ARM decodes the alarms. The ARM does not connect to the CELLBUS because it does not packetize user-data.

The ARM faceplate contains the alarm LEDs, ACO and History Clear push buttons, and the active and fail LEDs indicating the status of the ARM card (see Figure 4-26 and Table 4-29). The ARM card is used in conjunction with an ARI card. The ARI card connects to the ARM at the P2 connector. Relay drive signals originate in the ARM to operate relays on the ARI.

The ARM periodically runs a background self-test to determine the state of the card. If the card fails this self-test, the faceplate FAIL LED turns on, and the ACTIVE LED turns off.


Figure 4-26:
ARM Faceplate

Table 4-29:
ARM Faceplate Controls and Indicators

MINOR LED (yellow)

Indicates a failure in the local node that is not service-affecting but still should be investigated. It could indicate problems such as a loss of redundancy, a low error rate on a digital trunk (frame bit errors or bipolar errors), etc.

MAJOR LED (red)

Indicates a failure in the local node that is service-affecting, such as an IGX 8 card failure, that should be attended to immediately.

ACO LED (white)

Indicates that a MINOR or MAJOR alarm is present, and that the alarm cutoff (ACO) button (5) was pressed to silence an accompanying audible alarm. The ACO light is turned off when the alarm condition is cleared.

HISTory light (green)

Indicates that an alarm has occurred sometime in the past on the node. The alarm may be current or it may have cleared. Pressing the HIST CLR button (6) turns off this light if there is no current alarm.

ACO button

When pressed, silences audible alarm (visual alarms remain on) and turns on ACO light (3).

HIST CLR button

When pressed, turns off HIST light (4) if there is no current alarm.

FAIL light (red)

Indicates that the card has failed self-test (an error occurred). Resetting the card with the resetcd f command is suggested first. If the LED comes on again, call the StrataCom ISC.

ACTIVE light (green)

Indicates that the card is active, has been assigned using the addalmslot command, and is functioning normally.

The installation of the ARM cards requires the removal of the node from service. The ARM can be physically installed in any front slot except slots normally reserved for the node processor cards (NPMs). For standardization, StrataCom recommends that the ARM reside in the slot at the far right side of the card cage. The corresponding back slot must have an ARI card. The ARI card plugs directly in the ARM card.

User Commands

Three commands affect the ARM card set:

Alarm Relay Interface Description (ARI)

The Alarm Relay Interface (ARI) card contains the alarm relays and their associated relay drivers. Alarm outputs are dry contact closures or opening contacts from Form C relays. The user must supply the voltage source to be switched by the IGX. Any source or load can be switched as long as it meets the following requirements.

A female DB37 connector resides on the faceplate for connection to the customer's office alarm or alarm-reporting system. Refer to Figure 4-27 for an illustration of the ARI faceplate.


Figure 4-27: ARI Faceplate

Maintenance and Troubleshooting

The following paragraphs describe the maintenance and troubleshooting features associated with the ARM card set. Preventive maintenance is not necessary.

Card Self Test

As with all IGX 8 cards, the ARM has diagnostic routines that periodically run to test the card's performance. These self-test diagnostics are run in the background, so they do not disrupt normal traffic. If a failure is detected during the self test, the faceplate red FAIL LED is turned on. In addition, the status of the card can be checked at the control terminal by using the Display Card (dspcd) command.

If a card failure is reported, the report remains until cleared. A card failure is cleared by using the Reset Card (resetcd) command. Two types of resets are available. They are hardware and failure. The reset failure clears the event log of any failure detected by the card self test and does not disrupt card operation. The hardware reset reboots the firmware and resets the card, which momentarily disables the card.

Card Replacement

ARM card set replacement is the same as other card replacement. For these procedures, refer to the repair and replacement description in the IGX Installation Manual.

Optional Peripherals

At least one node in a network has a StrataView Plus terminal, a control terminal, or a dial-in modem connected to it. Any control terminal connected in the network can configure, manage, monitor, and diagnose the entire network. In addition, at least one node in a network may have a printer connected to it for printing error and event reports.

The control terminal and printer connect to two RS-232 serial ports. These ports are the Control Terminal and Auxiliary Port on the SCM faceplate. These serial ports support all standard asynchronous data rates from 1200 to 19,200 baud. The default rate is 9600 baud. Data rates and the type of equipment connected to the ports are software-configurable.

StrataCom recommends that at least one IGX in the network connects to a direct-dial modem so that StrataCom ISC personnel can perform remote diagnostic tests. A direct-dial modem connects to the backplane at the Control Terminal port. In addition, an auto-dial modem can be connected to the AUX port connector on the SCM at any node in the network so that remote error messages and alarms can be sent to the ISC, where they are automatically logged.

An external clock source can be connected to the SCM card using the external clock adapter cable. The external clock device can be either 1.544 MHz or 2.048 MHz RS-422 square wave signals depending on the primary application of the IGX (T1 or E1). Selection is made through software. The clock stability should be at least as good as a Stratum 3 clock source. The IGX Installation Manual lists the terminals, printers, modems and clock sources that have been tested and approved for use with the IGX.