This chapter lists information for the BPX system specifications. For the latest information, refer to Cisco online documents.
System Capacity: | 1 shelf with 15 card slots. |
Network Interface: | T3, E3, OC3, and OC12. |
Network Trunks: | 32 per node max. |
Network Interface Protocol: | ATM layer using 53-byte cell. |
Cell Switching: | Crosspoint switch matrix, non-blocking. |
Switch Capacity: | 9.6 Gbps or 19.2 Gbps (with BCC-4). |
Slot Rate: | 800 Mbps each, including overhead. |
Connection Rate: | 20 million cell connections/sec. between slots. |
Classes of Service: | 32 queues per port, assignable. |
Clock Sources: | Internal, free-running oscillator, Stratum 3. Phase-locked to any appropriate network interface. External input at T1 or E1 rate. |
Clock Output: | Single clock output at T1 or E1 rate for synchronizing co-located IGX node or CPE. |
Cabinet Size: | 22.75 inches (57.8 cm) high |
Weight, approx: | 73 lb. (33.2 kg.) empty BPX shelf, w/fans but no PS. |
Clearance Requirement: | At least 30 inches front and rear clearance; nominal 12 inch side clearance. |
Power Source: | AC system: 180 - 264 VAC, 47 to 63 Hz. |
Power Requirements: | AC BPX-15: 13 A at 180 VAC (2300 VA). |
Input Power Connector: | AC: 3-conductor IEC receptacle. 8 feet (2.4 m.) power cord supplied. |
Circuit Breakers: | AC: 15 A on AC power supply assembly. |
Fuses: | Individual Backplane Card slot fuses, F1 through F3 for Fans 1 through 3, and F4 through F18 for card slots 1 through 15, 5A-120VAC rating. |
Operating Environment: | Operating Conditions are listed in Table 31-1. |
Shock: | Withstands 10G, 10 ms. at 1/2 sine wave. |
Vibration: | Withstands 1/4 G, 20-500 Hz. |
Heat Transfer to Room: | Up to 7200 BTUs depending on node configuration. |
Conditions | Limits | |
---|---|---|
Fahrenheit | Centigrade | |
Operating Temperature Recommended | +40 to +100 degrees +68 to + 86 degrees | +4.5 to +38 degrees +20 to +30 degrees |
Short-Term Temperature1 | +35 to +120 degrees | +1.7 to + 49 degrees |
Operating Relative Humidity | 20% to 55% (non-condensing) | |
Short-Term Relative Humidity | 10% to 80% non-condensing |
1Room temperature refers to conditions at a location 5 feet above the floor and 15 inches in front of the equipment. |
Characteristic | T3 (DS3) | E3 |
Line Rate: | 44.736 Mbps +/- 20 ppm | 34.368 Mbps +/- 20 ppm |
Line Code: | B3ZS | HDB3 |
Cell Transfer Rate: | 96,000 cells per second (PLCP mode) 104268 cells per second (HEC/Direct mode) | 80,000 cells per second |
Framing: | ANSI T1.107, T1.107a | ITU T G804, G.832 |
Signal Level: | TA-TSY-000773 (PLCP) | ITU-T G.703 |
Transmission Convergence Sublayer: | DS3 PLCP frame format DS3 HEC mapped format | G.832 E3 frame format |
| T3 (DS3) and E3 | |
Port Interface, trunk mode, -framing: |
Framing for T3, C bit parity per ANSI T1.107/107A | |
-port alarm processing | RDI (yellow alarm) and AIS |
|
Port Interface, port (UNI) mode: |
|
|
ATM Layer Protocol: | LMI, ILMI | |
Port Alarm Processing: | LOS, LOF | |
Connector: | SMB |
Line Rate: | 622.08 Mbps |
|
Line Code: | NRZ |
|
Signal Level: | Min dBm | Max dBM |
SMF IR TX | -15 | -8 |
SMF IR RX | -28 | -8 |
SMF LR TX | -2 | +2 |
SMF LR RX | -28 | -8 |
Framing Format: | STS-12c, STM-4 | |
Port Interface: | LMI, ILMI | |
ATM Cell Rate: | 1,412,830 cells/sec. | |
Jitter: | ATM Forum UNI 3.1 | |
ATM Layer Protocol: | LMI, ILMI | |
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow | |
Line Errors Counted: |
| |
Connector: | SMF-FC | |
Max. Cable Lengths: | SMF IR ~20 KM | |
| SMF LR ~40 KM | |
Indicators: | Card status Port status |
Line Rate: | 44.736 Mbps ± 20 ppm, asynchronous. |
Line Code: | B3ZS. |
Signal Level: | DSX-3. |
Framing Format: | C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored. |
Protocol: | Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773. |
ATM Cell Rate: | 96,000 cells/sec. |
Alarms Sent: | Remote. |
Alarms Received: | AIS. |
Line Errors Counted: | BPV. |
Jitter: | Meets ACCUNET T45 specification (Pub 54014). |
Connector: | 75 ohm BNC. |
Recommended Cable Lengths: | 450 feet (150 m.) to a DS3 crossconnect. |
Indicators: | Card status. |
Line Rate: | 34.368 Mbps ± 20 ppm, asynchronous |
Line Code: | HDB3 |
Signal Level: | CCITT G.703 |
Framing Format: | CCITT G.804, G.832 |
Port Interface: | 75 ohm unbalanced |
Barrier: | Fully barriered per EN 41003 |
ATM Cell Rate: | 80,000 cells/sec |
Jitter: | per CCITT G.823 |
ATM Layer Protocol: | per CCITT I.361 with HEC |
Port Alarm Processing: | AIS |
Line Errors Counted: | BPV |
Connector: | 75 ohm BNC |
Max. E3 Cable Lengths: | 100 meters. Cabling must not exceed -6 dB/1000 feet at E3 rates. Cisco supplies cable with a maximum attenuation of 7 dB/1000 feet, but the maximum cable length must not exceed 100 meters. |
Indicators: | Card status |
Line Rate: | 155.52 Mbps |
|
Line Code: | NRZ |
|
Signal Level: | Max | Min |
MMF TX | -8 dBm | -15 dBm |
MMF RX | -8 dBm | -28 dBm |
SMF LR TX | 0 dBm | -5 dBM |
SMF LR RX | -10 dBm | -34 dBm |
Framing Format: | STS-3c, STM1 |
|
Port Interface: | LMI, ILMI |
|
ATM Cell Rate: | 353,208 cells/sec. |
|
Jitter: | < 0.1 UI p-p, < 0.01 UI rms | |
ATM Layer Protocol: | LMI, ILMI |
|
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow | |
Line Errors Counted: | Section BIP8, Line BIP24, Line FEBE, Path BIP8, Path FEBE | |
Connector: | MMF SC SMF FC/PC |
|
Max. Cable Lengths: | MMF ~ 2 KM | |
Indicators: | Card status |
|
Capacity: | 8 or 12 ports per card |
Interface: | DS3/T3/E3 |
Line Rate: | DS3 44.736 Mbs, E3 34.368 Mbps |
No. of channels per card: | 16,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 4 or 8 ports per card |
Interface: | OC-3c/STM-1 |
Line Rate: | 155.52.08 Mbps |
No. of channels per card: | 16,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 2 ports per card |
Interface: | OC-12c/STM-4 |
Line Rate: | 622.08 Mbps |
No. of channels per card: | 16,000/32,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 2 ports per card |
Interface: | T3 |
Line Rate: | 96,000 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues |
Capacity: | 2 ports per card |
Interface: | E3 |
Line Rate: | 80,000 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues |
Capacity: | 2 ports per card |
Interface: | OC3 |
Line Rate: | 353,208 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: |
|