cc/td/doc/product/wanbu/bpx8600/8_4
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Network Specifications

Network Specifications

This appendix lists preliminary information for Release 8.4. (Refer to on-line documents for latest information.)

Broadband Trunk Interfaces

Trunk Interfaces:

T3 and E3

Trunk Protocol:

Asynchronous Transfer Mode (ATM)

Trunks per Node:

32 DS3 or E3 trunks per BPX of which 16 can be shelf trunks

1 active DS3 or E3 trunk per IPX

Trunk Bandwidth:

96,000 cells/sec. (T3)

80,000 cells/sec. (E3)

Trunk Interfaces:

OC3

Trunk Protocol:

Asynchronous Transfer Mode (ATM)

Trunks per Node:

Trunk Bandwidth:

353,208 cells/sec (OC3))

Trunk Interfaces:

OC12

Trunk Protocol:

Asynchronous Transfer Mode (ATM)

Trunks per Node:

Trunk Bandwidth:

1,412,830 cells/sec

Narrowband Trunk Interfaces

North American:

T1

Fractional T1 (minimum of 4 DS0s)

T2

International:

CEPT E1

Subrate, 64 Kbps to 1.920 Mbps

Japanese "Y1"

Trunk Bandwidth:

1.536 Mbps, 8,000 FastPackets/sec. (T1)

1.984 Mbps, 10,333 FastPackets/sec. (framed E1)

2.048 Mbps, 10,666 FastPackets/sec. (unframed E1)

Subrate and fractional T1 depend on data rate selected

Narrowband Channel Interfaces

Frame Relay:

Channelized T1: 56 Kbps, N x 64 Kbps, up to 1.536 Mbps.

Channelized E1: G.703, N x 64 Kbps, up to 1.984 Mbps. V.35: configurable from 56 Kbps to 2.048 Mbps

Data:

V.35: 56 Kbps to 1.344 Mbps.

RS-449: 56 Kbps to 1.344 Mbps.

Voice:

Channelized T1

Channelized E1

Channelized Japanese

"TTC" DC5A and E&M channel associated signaling

FAX/high-speed modem

ATM Trunk Interface (BXM-T3/E3 Cards)

Characteristic: T3 (DS3) E3

Line Rate

44.736 Mbps +/- 20 ppm

34.368 Mbps +/- 20 ppm

Line Code

B3ZS

HDB3

Cell Transfer Rate

96,000 cells per second

80,000 cells per second

Framing

ANSI T1.107, T1.107a

ITU T G804, G.832

Signal Level

TA-TSY-000773 (PLCP)

ITU-T G.703

Transmission Convergence Sublayer

DS3 PLCP frame format

DS3 HEC mapped format

G.832 E3 frame format

T3 (DS3) and E3

Port Interface

Trunk or UNI

ATM Layer Protocol

LMI, ILMI

Port Alarm Processing

LOS, LOF

Connector

SMB

Indicators

Card status,

Port status

ATM Trunk Interface (BXM-155 Cards)

Line Rate

155.52 Mbps

Line Code

NRZ

Signal Level

Min dBm

Max dBM

MMF LED TX

-22

-15

MMF LED RX

-34

-10

SMF IR TX

-15

-8

SMF IR RX

-34

-10

SMF LR TX

-5

0

SMF LR RX

-34

-10

Framing Format:

STS-3c, STM-1

Port Interface:

LMI, ILMI

ATM Cell Rate:

353,208 cells/sec.

Jitter:

ATM Forum UNI 3.1

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Connector:

SC for MMF, FC-PC for SMF (IR) and SMF (LR)

Max. Cable Lengths:

MMF ~2 KM

SMF IR ~20 KM

SMF LR ~40 KM

Indicators:

Card status,

Port status.

ATM Trunk Interface (BXM-622 Cards)

Line Rate

622.08 Mbps

Line Code

NRZ

Signal Level

Min dBm

Max dBM

SMF IR TX

-15

-8

SMF IR RX

-28

-8

SMF LR TX

-2

+2

SMF LR RX

-28

-8

Framing Format:

STS-12c, STM-4

Port Interface:

LMI, ILMI

ATM Cell Rate:

1,412,830 cells/sec.

Jitter:

ATM Forum UNI 3.1

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Connector:

SMF-FC

Max. Cable Lengths:

MMF ~2 KM

SMF IR ~20 KM

SMF LR ~40 KM

Indicators:

Card status,

Port status.

ATM T3 Trunk Interface (BNI-T3, LM-3T3)

Line Rate:

44.736 Mbps ±20 ppm, asynchronous

Line Code:

B3ZS

Signal Level:

DSX-3

Framing Format:

C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored

Protocol:

Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773

ATM Cell Rate:

96,000 cells/sec. Limited to 80,000 cells/sec. when interfacing with the IPX

Alarms Sent:

AIS
Remote

Alarms Received:

AIS
Loss of Signal
Remote
Loss of Framing

Line Errors Counted:

BPV.
Parity Bit Errors

Jitter:

Meets ACCUNET T45 specification (Pub 54014)

Connector:

75 ohm BNC

Recommended Cable Lengths:

900 feet (275 m.) max. using specified cable
450 feet (150 m.) to a DS3 crossconnect

Indicators:

Card status

Port status

ATM E3 Trunk Interface (BNI-E3, LM-3E3)

Line Rate:

34.368 Mbps ± 20 ppm, asynchronous

Line Code:

HDB3

Signal Level:

CCITT G.703

Framing Format:

CCITT G.804, G.832

Port Interface:

75 ohm unbalanced

Barrier:

Fully barriered per EN 41003

ATM Cell Rate:

80,000 cells/sec

Jitter:

per CCITT G.823

ATM Layer Protocol:

per CCITT I.361 with HEC

Port Alarm Processing:

AIS
Loss of Signal
Remote Alarm Indication
Loss of Framing

Line Errors Counted:

BPV.
Parity Bit Errors

Connector:

75 ohm BNC

Max. E3 Cable Lengths:

900 feet (275 m.) using specified cable

Indicators:

Card status
Port status

ATM OC3 Trunk Interface (BNI-OC3, LM-OC3

Line Rate:

155.52 Mbps

Line Code:

NRZ

Signal Level:

Max

Min

MMF TX

-8 dBm

-15 dBm

MMF RX

-8 dBm

-28 dBm

SMF LR TX

0 dBm

-5 dBM

SMF LR RX

-10 dBm

-34 dBm

Framing Format:

STS-3c, STM1

Port Interface:

LMI, ILMI

ATM Cell Rate:

353,208 cells/sec

Jitter:

< 0.01 UI p-p, < 0.1 UI rms

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Section BIP8, Line BIP24, Line FEBE,

Path BIP8, Path FEBE

Connector:

MMF SC

SMF FC/PC

Max. Cable Lengths:

MMF ~ 2 KM

SMF IR ~20 KM

SMF LR ~40 KM

Indicators:

Card status

Port status

ATM Service Interface (BXM-T3/E3 Cards)

Capacity:

8 or 12 ports per card.

Interface:

DS3/T3

Line Rate:

DS3 44.736 Mbs, E3 34.368 Mbps

No. of channels per card:

16,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (BXM-155 Cards)

Capacity:

4 or 8 ports per card.

Interface:

OC-3c/STM-1

Line Rate:

155.52 Mbps

No. of channels per card:

16,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (BXM-622 Cards)

Capacity:

2 ports per card.

Interface:

OC-12c/STM-4

Line Rate:

622.08 Mbps

No. of channels per card:

16,000/32,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (ASI-1, LM-2T3)

Capacity:

2 ports per card

Interface:

T3

Line Rate:

96,000 cells/sec

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues.

ATM Service Interface (ASI-1, LM-2E3)

Capacity:

2 ports per card.

Interface:

E3

Line Rate:

80,000 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues.

ATM Service Interface (ASI-2, LM-OC3)

Capacity:

2 ports per card.

Interface:

OC3

Line Rate:

353,208 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:

24, 12 per line (port) includes CBR and VBR queues

Network Synchronization

Network Clock:

One clock source per domain must be defined. Network clock cannot propagate across domain boundary.

Node Clock:

44.736 MHz, ±50 Hz (Stratum 3 per AT&T Pub 62411). Internal 8 KHz and 192 KHz clocks for synchronizing network interfaces.

Clock Sources:

Internal, free-running oscillator. Phase-locked to any appropriate network interface. External input at T1 or E1 rate.

Clock Output:

Single clock output at T1 or E1 rate for synchronizing co-located IPX node(s) or CPE.

Clocking Hierarchy:

Network-wide or domain-wide (for structured networks) clock selection.

Network Management

NMS Terminal:

SUN Microsystems and StrataView Plus, Informix, Wingz, and HP OpenView software required for network management, connection provisioning, graphical display of network status, statistics gathering and display, automatic downloading of switch software, and save and restore of node configurations.

Control Terminal:

DEC VT100 or equivalent terminal for basic system configuring and alarm monitoring.

Remote Alarm Reporting:

Autodial modem may be connected to the auxiliary port on one or more IPX or IGX nodes for automatic reporting of network alarms.

Remote Diagnostics:

Autoanswer modem may be connected to the control port one or more IPX, IGX, or BPX nodes for remote diagnostic access by Cisco Customer Service or other authorized personnel.

Network Control Ports:

Three ports per node, two with RS 232C interface, one with Ethernet LAN interface. (Nodes with PCC controller have only the two RS-232 ports).

Alarm Notification:

Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus terminal at connecting node.

External Alarms:

Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Jan 18 13:00:39 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.