cc/td/doc/product/wanbu/access/aprod
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Cables

Cables

This appendix describes all the cables available from Cisco for use with your FastPAD. These cables are built to the following standards:

    1. 93 percent minimum braid coverage.

    2. Full die-cast metal back shells on the connector.

    3. Full, 360 degree, shield termination to the back shell of the connector, full bonding.

    4. Braid is captured in a metal thimble to prevent loss of bonding. This thimble traps the braid and provides good contact to the shell for a full 360 degree connection to the shell. No plastic grommets for braid capture are ever used.

    5. Full 360 degree braid bonding.

Table C-1 lists cable designations, by table, in this appendix.


Table C-1: Cable Designations
Table Cable Designation DB25M to... Interface Card

Table C-2

OPALE

DIN to DB25, DB9F

Table C-4

Direct V.24/V.28

DB25 male

IF-V.28

Table C-5

Direct V.35

34P male

Table C-6

Direct X.21/V.11

DB15 male

IF-V.28

Table C-7

Direct X.21bis
V.10/V.11 DTE

RS449 male
37 pin

Table C-8

Direct X.21bis
V.10/V.11 DCE

RS449 male
37 pin

IF-V.28

Table C-9

Crossed cable
V.24 DTE
(125 managed)

DB25 male

Table C-10

Crossed cable
V.24 DTE
(117 managed)

DB25 male

IF-V.28

Table C-11

Crossed cable
X.21/V.11 DTE

X.21
15 pin

Table C-12

French Videotext
Terminal Cable

IF-V.28

Table C-13

RJ45 Crossed Cable for G.703

RJ45 to RJ45

IF-V.28

Front Panel DIN Connector Cable

Table C-2 lists the front panel DIN connector pins and signals. Figure C-1 shows the DIN connectors attached to the DB-25 and DB-9 connectors. Table C-3 lists the DIN connector pinouts.


Table C-2: Front Panel DIN Connector Cable
DIN Connector Pin Signal Function

1

RBGA

CT104 V.28 DCE

System

Monitor

Dbug

VT

2

TBGA

CT103 V.28 DCE

3

Logic 0

Logical Ground

6

RBGB

CT104 V.28 DCE

8

TBGB

CT103 V.28 DCE

VT

4

WDBL

Watchdog Output 1

7

Reserved

5

Ground

Equipment Ground

1The front panel DIN connector outputs a "Watchdog" signal on Pin 4. Signal OFF indicates operating unit; Signal ON indicates faulty unit. (Corresponding software module must also be installed.) This is an open collector output.

Figure C-1:
DIN Connector Attached to the DB-25 and DB-9 Connectors



Note Use the STD DIN connector size, not the mini.

Table C-3:
DIN Connector Pinout
Signal DIN-8 Pin Number DEBUG DB-25 PIN Number TERM DB-9 PIN Number DEBUG DB-9 PIN Number

RBGA

1

(2)

(3)

TBGA

2

(3)

(2)

Logic ø

3

(7)

(5)

(5)

RBGB

6

(3)

TBGB

8

(2)

GND

5

(7-8)1

1Jumper pins 7 and 8 on the DB-9 connector (CTS and RTS).

Direct V.28 Cable

The V.28 cable is a shielded, 9 twisted-pair cable for use with the a V.28 interface card. For the mp6, Line 0 and Line 1-5 in DCE. (See Table C-4.)


Table C-4: Direct V.28 Cable
RS232 P1 Male
DB25
ISO 2110
RS232P2 Male
DB25
ISO 2110
Signals Abbreviations

1

1

Shield

FG

2

2

103 (Transmitted Data)

TD

3

3

104 (Received Data)

RD

4

4

105 (Request to Send)

RTS

5

5

106 (Clear to Send)

CTS

6

6

107 (Data Set Ready)

DSR

8

8

109 (Data Carrier Detector)

DCD

15

15

114 (Transmit Element Timing)

TC

7

7

102 (Signal Ground)

GND

17

17

115 (Receive Element Timing)

RC

18

18

141 (Local Loopback (loop 3))

LL

20

20

108 (Data Terminal Ready)

DTR

21

21

140 (Remote Interface Loop (loop 2))

RIL

10

10

117 (Standby Indicator)

SI

9

9

116 (Selector (DTE))

22

22

125 (Ring Indicator)

RI

23

23

111 (Data Signal Rate Selector (DTE))

DRS

25

25

142 (Test Indicator)

TI

Direct V.35 Cable

The V.35 cable is a 12 twisted-pair shielded cable for use with the a V35 interface card. (See Table C-5.)

On line 0 for the mp6.


Table C-5: Direct V.35 Cable
RS232 P1 Male DB25 ISO 2110 P2 Male 34-pin ISO 2593 Signals Abbreviations

17

V

115A (Receive Element Timing)

RC

12

X

115B (Receive Element Timing)

RC

15

Y

114A (Transmit Element Timing)

TC

13

AA

114B (Transmit Element Timing)

TC

3

R

104A (Received Data)

RD

16

T

104B (Received Data)

RD

2

P

103A (Transmitted Data)

TD

14

S

103B (Transmitted Data)

TD

7

B

102 (Signal Ground)

GND

5

D

106 (Clear to Send)

CTS

8

F

109 (Data Carrier Detector)

DCD

22

J

125 Ring indicator

RI

18

L

141 (Local Loopback (loop 3))

LL

21

N

140 (Remote Interface Loop (loop 2))

RIL

6

E

107 (Data Set Ready)

DSR

20

H

108 (Data Terminal Ready)

DTR

4

C

105 (Request to Send)

RTS

25

NN

142 (Test Indicator)

-

1

A

Shield (Cable Screening)

FG

24

U

113A (Transmit Clock to modem)

TC

11

W

113B (Select Transmit Frequency)

QM

Direct X.21/V.11 Cable

The V.11 cable is a 6 twisted-pair, shielded cable for use with a V.11 interface card. (See Table C-6.)

For the mp6 on line L0 and L1 and L3 if V.11 DCE.


Table C-6: Direct X.21/V.11 Cable
RS232 P1 Male
DB25
ISO 2110
P2 Male
15-pin
ISO 4903
Signals

1

1

Shield

7

8

Ground

2

2

TA

Transmit

14

9

TB

3

4

RA

Receive

16

11

RB

4

3

CA

Control

23

10

CB

8

5

IA

Indication

9

12

IB

15

6

SA

Signal Element Timing

13

13

SB

X.21bis V.10/V.11 DTE Cable

The X.21bis DTE cable is a 12 twisted-pair shielded cable used to connect a V.11 interface card to a DTE device. For line 0 on the mp6. (See Table C-7.)


Table C-7: X.21bis V.10/V.11 DTE Cable
RS232 P1 Male
DB25
ISO 2110
RS449 P2 Male
37-pin
ISO 4902
Signals Abbreviations

1

1

Shield

FG

7

37

102A (Signal Ground)

GND

10

20

102B (Common Ground)

CG

2

4

103A (Transmitted Data)

TD

14

22

103B (Transmitted Data)

(S)TD

3

6

104A (Received Data)

RD

16

24

104B (Received Data)

(S)RD

4

7

105A (Request to Send)

RTS

23

25

105B (Request to Send)

DRS

5

9

106 (Clear to Send)

CTS

10

27

102B (Common Ground)

CG

6

11

10 7 (Data Set Ready)

DSR

10

29

102B (Common Ground)

CG

20

12

108 (Data Terminal Ready)

-

7

30

102A (Signal Ground)

GND

8

13

109A (Data Carrier Detector)

DCD

9

31

109B (Carrier Detect)

CD

15

5

114A (Transmit Element Timing)

TC

13

23

114B (Transmit Element Timing)

(S)CTS

17

8

115A (Receive Element Timing)

RC

12

26

115B (Receive Element Timing)

(S)DCD

21

14

140 (Remote Interface loop (loop 2))

RIL

18

10

141 (Local loopback (loop 3))

LL

25

18

142 (Test Indicator)

-

X.21bis V.10/V.11 DCE Cable

The X.21bis DCE cable is a 12 twisted-pair shielded cable used to connect a V.11 interface card to a DCE device. For line 0 on the mp6. (See Table C-8.)


Table C-8: X.21bis V.10/V.11 DCE Cable
RS232 P1 Male
DB25
ISO 2110
RS449 P2 Male
37-pin
ISO 4902
Signals Abbreviations

1

1

Shield

FG

10

37

102A (Signal Ground)

GND

7

20

102B (Common Ground)

CG

2

4

103A (Transmitted Data)

TD

14

22

103B (Transmitted Data)

(S)TD

3

6

104A (Received Data)

RD

16

24

104B (Received Data)

(S)RD

4

7

105A (Request to Send)

RTS

23

25

105B (Request to Send)

DRS

5

9

106 (Clear to Send)

CTS

7

27

102B (Common Ground)

CG

6

11

107 (Data Set Ready)

DSR

7

29

102B (Common Ground)

CG

20

12

108 (Data Terminal Ready)

DTR

10

30

102A (Signal Ground)

8

13

109A (Data Carrier Detector)

DCD

9

31

109B (Carrier Detect)

CD

15

5

114A (Transmit Element Timing)

TC

13

23

114B (Transmit Element Timing)

(S)CTS

17

8

115A (Receive Element Timing)

RC

12

26

115B (Receive Element Timing)

(S)DCD

21

14

140 (Remote Interface loop (loop 2))

RIL

18

10

141 (Local Loopback (loop 3))

LL

25

18

142 (Test Indicator)

--

Crossed Cable V.24 DTE (125 Managed)

This cable is only for the mp6, Lines L1-L5:

See Table C-9.


Table C-9: Crossed Cable V.24 DTE (125 managed)
Signals P1 25 pts M (ISO 2110) P2 25 pts M (ISO 2110) Signals

Shield

1

1

Shield

103

2

3

104

104

3

2

103

102

7

7

102

115

17

15

114

109

8

4

105

108

20

5

106

114

15

17

115

105

4

8

109

111

23

6

107

106

5

20

108

142

25

21

140

117

10

18

141

125

22

18

141

141

18

22

125

107

6

23

111

140

21

25

142

Crossed Cable V.24 (117 Managed)

This cable is only for the mp6, Lines L1-L5:


Table C-10: Crossed Cable V.24 DTE (117 Managed)
Signals P1 25 pts M (ISO 2110) P2 25 pts M (ISO 2110) Signals

Shield

1

1

Shield

102

7

7

102

115

17

15

114

104

3

2

103

103

2

3

104

109

8

4

105

108

20

5

106

114

15

17

115

111

23

6

107

105

4

8

109

106

5

20

108

142

25

21

140

117

10

18

141

125

22

18

141

141

18

10

117

107

6

23

111

140

21

25

142

Crossed Cable X.21/V.11 DTE

This cable is only for Lines L1-L3 on the mp6:

See Table C-11.


Table C-11: Crossed Cable X.21/V.11 DTE
Signals P1 25 pts M (ISO 2110) P2 25 pts M (ISO 4903) Signals

102

7

8

102

104A

3

2

103A

104B

16

9

103B

103A

2

4

104A

103B

14

11

104B

109A

8

3

105A

109B

9

10

105B

105A

4

5

109A

105B

23

12

109B

114A

15

6

114A

114B

13

13

114B

French Videotext Terminal Cable

This cable is for use with the IF-TTL card:

See Table C-12.


Table C-12: French Videotext Terminal Cable
P1 25 pts M (ISO 2110) P2 5 pts M Signals

2

1

CT103

3

3

CT104

7

2 and 4

CT102

RJ-45 Crossed Cable for G.703

The RJ-45 cable included with the G.703 interface kit is a male-to-male crossover cable with the signals listed in Table C-13.


Table C-13: RJ-45 Crossed Cable for G.703
P1 Signal P2 Signal

5

TXPRY

2

RCPRY

4

TRPRX

1

RCPRX

2

RCPRY

5

TRPRY

1

RCPRX

4

TRPTRX

6

NC

6

NC

3

NC

3

NC

8

NC

8

NC

7

NC

7

NC


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Jan 25 14:10:03 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.