This appendix describes all the cables available from Cisco for use with your FastPAD. These cables are built to the following standards:
1. 93 percent minimum braid coverage.
2. Full die-cast metal back shells on the connector.
3. Full, 360 degree, shield termination to the back shell of the connector, full bonding.
4. Braid is captured in a metal thimble to prevent loss of bonding. This thimble traps the braid and provides good contact to the shell for a full 360 degree connection to the shell. No plastic grommets for braid capture are ever used.
5. Full 360 degree braid bonding.
Table C-1 lists cable designations, by table, in this appendix.
Table | Cable Designation | DB25M to... | Interface Card |
---|---|---|---|
OPALE | DIN to DB25, DB9F |
| |
Direct V.24/V.28 | DB25 male | IF-V.28 | |
Direct V.35 | 34P male |
| |
Direct X.21/V.11 | DB15 male | IF-V.28 | |
Direct X.21bis | RS449 male |
| |
Direct X.21bis | RS449 male | IF-V.28 | |
Crossed cable | DB25 male |
| |
Crossed cable | DB25 male | IF-V.28 | |
Crossed cable | X.21 |
| |
French Videotext |
| IF-V.28 | |
RJ45 Crossed Cable for G.703 | RJ45 to RJ45 | IF-V.28 |
Table C-2 lists the front panel DIN connector pins and signals. Figure C-1 shows the DIN connectors attached to the DB-25 and DB-9 connectors. Table C-3 lists the DIN connector pinouts.
DIN Connector Pin | Signal | Function | |
---|---|---|---|
1 | RBGA | CT104 V.28 DCE | System Monitor Dbug VT |
2 | TBGA | CT103 V.28 DCE | |
3 | Logic 0 | Logical Ground | |
6 | RBGB | CT104 V.28 DCE | |
8 | TBGB | CT103 V.28 DCE | VT |
4 | WDBL | Watchdog Output 1 |
|
7 |
| Reserved |
|
5 | Ground | Equipment Ground |
|
Signal | DIN-8 Pin Number | DEBUG DB-25 PIN Number | TERM DB-9 PIN Number | DEBUG DB-9 PIN Number |
---|---|---|---|---|
RBGA | 1 | (2) |
| (3) |
TBGA | 2 | (3) |
| (2) |
Logic ø | 3 | (7) | (5) | (5) |
RBGB | 6 |
| (3) |
|
TBGB | 8 |
| (2) |
|
GND | 5 |
|
|
|
|
|
| (7-8)1 |
|
1Jumper pins 7 and 8 on the DB-9 connector (CTS and RTS). |
The V.28 cable is a shielded, 9 twisted-pair cable for use with the a V.28 interface card. For the mp6, Line 0 and Line 1-5 in DCE. (See Table C-4.)
RS232
P1 Male DB25 ISO 2110 | RS232P2 Male DB25 ISO 2110 | Signals | Abbreviations |
---|---|---|---|
1 | 1 | Shield | FG |
2 | 2 | 103 (Transmitted Data) | TD |
3 | 3 | 104 (Received Data) | RD |
4 | 4 | 105 (Request to Send) | RTS |
5 | 5 | 106 (Clear to Send) | CTS |
6 | 6 | 107 (Data Set Ready) | DSR |
8 | 8 | 109 (Data Carrier Detector) | DCD |
15 | 15 | 114 (Transmit Element Timing) | TC |
7 | 7 | 102 (Signal Ground) | GND |
17 | 17 | 115 (Receive Element Timing) | RC |
18 | 18 | 141 (Local Loopback (loop 3)) | LL |
20 | 20 | 108 (Data Terminal Ready) | DTR |
21 | 21 | 140 (Remote Interface Loop (loop 2)) | RIL |
10 | 10 | 117 (Standby Indicator) | SI |
9 | 9 | 116 (Selector (DTE)) |
|
22 | 22 | 125 (Ring Indicator) | RI |
23 | 23 | 111 (Data Signal Rate Selector (DTE)) | DRS |
25 | 25 | 142 (Test Indicator) | TI |
The V.35 cable is a 12 twisted-pair shielded cable for use with the a V35 interface card. (See Table C-5.)
On line 0 for the mp6.
RS232 P1 Male DB25 ISO 2110 | P2 Male 34-pin ISO 2593 | Signals | Abbreviations |
---|---|---|---|
17 | V | 115A (Receive Element Timing) | RC |
12 | X | 115B (Receive Element Timing) | RC |
15 | Y | 114A (Transmit Element Timing) | TC |
13 | AA | 114B (Transmit Element Timing) | TC |
3 | R | 104A (Received Data) | RD |
16 | T | 104B (Received Data) | RD |
2 | P | 103A (Transmitted Data) | TD |
14 | S | 103B (Transmitted Data) | TD |
7 | B | 102 (Signal Ground) | GND |
5 | D | 106 (Clear to Send) | CTS |
8 | F | 109 (Data Carrier Detector) | DCD |
22 | J | 125 Ring indicator | RI |
18 | L | 141 (Local Loopback (loop 3)) | LL |
21 | N | 140 (Remote Interface Loop (loop 2)) | RIL |
6 | E | 107 (Data Set Ready) | DSR |
20 | H | 108 (Data Terminal Ready) | DTR |
4 | C | 105 (Request to Send) | RTS |
25 | NN | 142 (Test Indicator) | - |
1 | A | Shield (Cable Screening) | FG |
24 | U | 113A (Transmit Clock to modem) | TC |
11 | W | 113B (Select Transmit Frequency) | QM |
The V.11 cable is a 6 twisted-pair, shielded cable for use with a V.11 interface card. (See Table C-6.)
For the mp6 on line L0 and L1 and L3 if V.11 DCE.
RS232
P1 Male DB25 ISO 2110 | P2 Male 15-pin ISO 4903 | Signals | |
---|---|---|---|
1 | 1 | Shield |
|
7 | 8 | Ground |
|
2 | 2 | TA | Transmit |
14 | 9 | TB |
|
3 | 4 | RA | Receive |
16 | 11 | RB |
|
4 | 3 | CA | Control |
23 | 10 | CB |
|
8 | 5 | IA | Indication |
9 | 12 | IB |
|
15 | 6 | SA | Signal Element Timing |
13 | 13 | SB |
|
The X.21bis DTE cable is a 12 twisted-pair shielded cable used to connect a V.11 interface card to a DTE device. For line 0 on the mp6. (See Table C-7.)
RS232
P1 Male DB25 ISO 2110 | RS449
P2 Male 37-pin ISO 4902 | Signals | Abbreviations |
---|---|---|---|
1 | 1 | Shield | FG |
7 | 37 | 102A (Signal Ground) | GND |
10 | 20 | 102B (Common Ground) | CG |
2 | 4 | 103A (Transmitted Data) | TD |
14 | 22 | 103B (Transmitted Data) | (S)TD |
3 | 6 | 104A (Received Data) | RD |
16 | 24 | 104B (Received Data) | (S)RD |
4 | 7 | 105A (Request to Send) | RTS |
23 | 25 | 105B (Request to Send) | DRS |
5 | 9 | 106 (Clear to Send) | CTS |
10 | 27 | 102B (Common Ground) | CG |
6 | 11 | 10 7 (Data Set Ready) | DSR |
10 | 29 | 102B (Common Ground) | CG |
20 | 12 | 108 (Data Terminal Ready) | - |
7 | 30 | 102A (Signal Ground) | GND |
8 | 13 | 109A (Data Carrier Detector) | DCD |
9 | 31 | 109B (Carrier Detect) | CD |
15 | 5 | 114A (Transmit Element Timing) | TC |
13 | 23 | 114B (Transmit Element Timing) | (S)CTS |
17 | 8 | 115A (Receive Element Timing) | RC |
12 | 26 | 115B (Receive Element Timing) | (S)DCD |
21 | 14 | 140 (Remote Interface loop (loop 2)) | RIL |
18 | 10 | 141 (Local loopback (loop 3)) | LL |
25 | 18 | 142 (Test Indicator) | - |
The X.21bis DCE cable is a 12 twisted-pair shielded cable used to connect a V.11 interface card to a DCE device. For line 0 on the mp6. (See Table C-8.)
RS232
P1 Male DB25 ISO 2110 | RS449
P2 Male 37-pin ISO 4902 | Signals | Abbreviations |
---|---|---|---|
1 | 1 | Shield | FG |
10 | 37 | 102A (Signal Ground) | GND |
7 | 20 | 102B (Common Ground) | CG |
2 | 4 | 103A (Transmitted Data) | TD |
14 | 22 | 103B (Transmitted Data) | (S)TD |
3 | 6 | 104A (Received Data) | RD |
16 | 24 | 104B (Received Data) | (S)RD |
4 | 7 | 105A (Request to Send) | RTS |
23 | 25 | 105B (Request to Send) | DRS |
5 | 9 | 106 (Clear to Send) | CTS |
7 | 27 | 102B (Common Ground) | CG |
6 | 11 | 107 (Data Set Ready) | DSR |
7 | 29 | 102B (Common Ground) | CG |
20 | 12 | 108 (Data Terminal Ready) | DTR |
10 | 30 | 102A (Signal Ground) |
|
8 | 13 | 109A (Data Carrier Detector) | DCD |
9 | 31 | 109B (Carrier Detect) | CD |
15 | 5 | 114A (Transmit Element Timing) | TC |
13 | 23 | 114B (Transmit Element Timing) | (S)CTS |
17 | 8 | 115A (Receive Element Timing) | RC |
12 | 26 | 115B (Receive Element Timing) | (S)DCD |
21 | 14 | 140 (Remote Interface loop (loop 2)) | RIL |
18 | 10 | 141 (Local Loopback (loop 3)) | LL |
25 | 18 | 142 (Test Indicator) | -- |
This cable is only for the mp6, Lines L1-L5:
See Table C-9.
Signals | P1 25 pts M (ISO 2110) | P2 25 pts M (ISO 2110) | Signals |
---|---|---|---|
Shield | 1 | 1 | Shield |
103 | 2 | 3 | 104 |
104 | 3 | 2 | 103 |
102 | 7 | 7 | 102 |
115 | 17 | 15 | 114 |
109 | 8 | 4 | 105 |
108 | 20 | 5 | 106 |
114 | 15 | 17 | 115 |
105 | 4 | 8 | 109 |
111 | 23 | 6 | 107 |
106 | 5 | 20 | 108 |
142 | 25 | 21 | 140 |
117 | 10 | 18 | 141 |
125 | 22 | 18 | 141 |
141 | 18 | 22 | 125 |
107 | 6 | 23 | 111 |
140 | 21 | 25 | 142 |
This cable is only for the mp6, Lines L1-L5:
Signals | P1 25 pts M (ISO 2110) | P2 25 pts M (ISO 2110) | Signals |
Shield | 1 | 1 | Shield |
102 | 7 | 7 | 102 |
115 | 17 | 15 | 114 |
104 | 3 | 2 | 103 |
103 | 2 | 3 | 104 |
109 | 8 | 4 | 105 |
108 | 20 | 5 | 106 |
114 | 15 | 17 | 115 |
111 | 23 | 6 | 107 |
105 | 4 | 8 | 109 |
106 | 5 | 20 | 108 |
142 | 25 | 21 | 140 |
117 | 10 | 18 | 141 |
125 | 22 | 18 | 141 |
141 | 18 | 10 | 117 |
107 | 6 | 23 | 111 |
140 | 21 | 25 | 142 |
This cable is only for Lines L1-L3 on the mp6:
See Table C-11.
Signals | P1 25 pts M (ISO 2110) | P2 25 pts M (ISO 4903) | Signals |
---|---|---|---|
102 | 7 | 8 | 102 |
104A | 3 | 2 | 103A |
104B | 16 | 9 | 103B |
103A | 2 | 4 | 104A |
103B | 14 | 11 | 104B |
109A | 8 | 3 | 105A |
109B | 9 | 10 | 105B |
105A | 4 | 5 | 109A |
105B | 23 | 12 | 109B |
114A | 15 | 6 | 114A |
114B | 13 | 13 | 114B |
This cable is for use with the IF-TTL card:
See Table C-12.
P1 25 pts M (ISO 2110) | P2 5 pts M | Signals |
---|---|---|
2 | 1 | CT103 |
3 | 3 | CT104 |
7 | 2 and 4 | CT102 |
The RJ-45 cable included with the G.703 interface kit is a male-to-male crossover cable with the signals listed in Table C-13.
P1 | Signal | P2 | Signal |
---|---|---|---|
5 | TXPRY | 2 | RCPRY |
4 | TRPRX | 1 | RCPRX |
2 | RCPRY | 5 | TRPRY |
1 | RCPRX | 4 | TRPTRX |
6 | NC | 6 | NC |
3 | NC | 3 | NC |
8 | NC | 8 | NC |
7 | NC | 7 | NC |