Table Of Contents
Cisco Systems Hardware and Software Requirements
PBX Hardware and Software Requirements
Calling Name and Number feature.
Configuring the Siemens Hicom 330 E PBX
Siemens Hicom 330 E PBX Configuration Menus and Commands
Configuring the Cisco CallManager
Layers 2 & 3 (Q.921 and Q.931)
Call Manager Components Release
Siemens Hicom 330 E Software release
Cisco 3640 Router Configuration
Application Note
Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 3640-E1 MGCP Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager the 3640-E1 PRI as the MGCP Gateway.
Introduction
•
The Network Topology diagram shows the test set-up for end-to-end interoperability between the Cisco CallManager connected to the PBX via 3640-E1 link as MGCP Gateway.
•
Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E PBX.
•
CallManager fails to return the "Connected Number" in the Connect message.
•
Connectivity is achieved by using the industry standard ETSI protocol. The Siemens Hicom 330 E can be configured as either NETWORK (Master) or USER (Slave) side.
Network Topology
Figure 1 Basic Setup
Cisco Systems Hardware and Software Requirements
•
Cisco 3640 Gateway with 2MFT E1 Port
•
Cisco Cat6K switch
•
Cisco CallManager 3.2
•
IOS software releases "c3640-js-mz.122-2.XN
PBX Hardware and Software Requirements
•
Hardware: DIU-N2
•
Software: Version 3.1
Features Supported
Key Features Supported
Calling/Called Number
Key Features Not Supported
Connected Number
Limitations
Calling Name and Number feature.
•
Calling Name deliver and presentation features are not supported by the Siemens Hicom 330 E PBX.
•
When calling from Cisco 7960 IP phone to Siemens digital phone, both phones display Calling Number after the call is answered as expected.
•
When calling from Siemens digital phone to Cisco 7960 IP phone, the Cisco IP phone displays Connected Number after the call is answered. When calling from the Siemens phone, the Connected Number is not displayed on the Siemens phone. It displays the numbers being dialed instead (i.e. Access Code + extension number). It was verified using the an ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.
Configuring the Siemens Hicom 330 E PBX
Use the following steps to configure the Siemens Hicom 330 E PBX.
Step 1.
Add the new access code to Dialing Plans using WABE + LDPLN.
Step 2.
Add the new trunk board using BCSU.
Step 3.
Configure Class of Trunk using COT.
Step 4.
Configure Class of Parameter for device handler using COP.
Step 5.
Configure Class of Service using COSSU.
Step 6.
Add the new trunk group access code using BUEND.
Step 7.
Configure trunk using TDCSU.
Step 8.
Configure Reference Clock using REFTA.
Step 9.
Configure trunk Least Cost Routing using LDAT + RICHT.
Step 10.
Configure LCR Out-dial Rules using LODR.
Siemens Hicom 330 E PBX Configuration Menus and Commands
Step 1.
Add the new access code to Dialing Plans using WABE + LDPLN.
<dis-wabeTYPE = genCD =DPLN = 0;DIS-WABE:GEN,,0;H500: AMO WABE STARTED------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 001 - 002 |* ..... ..... ..... ..... ..| NETRTE | || 11 |. ..... ..... ..... ....* ..| MBKY | || 3001 |. .**** ***** **... ..... ..| STN | R || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 3007 |. ..... ..... ..... ....* ..| MBKY | || 3007 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 4100 - 4500 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 72 || | | |DNNO 1- 1-702 |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 5000 - 5007 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 0 || | | |DNNO 1- 1-150*|| 5008 - 5009 |. .**** ***** **... ..... ..| STN | || | | |DESTNO 99 || | | |DNNO 1- 1- 99 || 5010 |. .**** *.*** **... ..... ..| ATNDIND | || 800 |. ..... *...* **... ..... ..| ATNDDID | || 854 |. .**** ***** **... ..... ..| NETW | R || | | |DESTNO 2 || | | |DNNO 0- 0- 0 || *66 |. ....* ..... ..... ..... ..| SIGNON | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *91 |. ....* ....* ..... ..... ..| MBOFF | || #66 |. ....* ..... ..... ..... ..| SIGNOFF | || #91 |. ....* ....* ..... ..... ..| MBON | || ##22 |. ..... ..... ..... ....* ..| DAKY | || ##24 |. ..... ..... ..... ....* ..| DSSKY | || ##25 |. ..... ..... ..... ....* ..| FWDKY | || ##26 |. ..... ..... ..... ....* ..| HTKY | || ##27 |. ..... ..... ..... ....* ..| KNOVRKY | || ##28 |. ..... ..... ..... ....* ..| MBKY | || ##29 |. ..... ..... ..... ....* ..| MSGRKY | || ##35 |. ..... ..... ..... ....* ..| TIMEKY | || ##36 |. ..... ..... ..... ....* ..| VCKY | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| ##37 |. ..... ..... ..... ....* ..| VCRKY | || ##38 |. ..... ..... ..... ....* ..| CCKY | || ##39 |. ..... ..... ..... ....* ..| CONFKY | || ##41 |. ..... ..... ..... ....* ..| NAMEKY | || ##42 |. ..... ..... ..... ....* ..| PARKKY | || ##43 |. ..... ..... ..... ....* ..| REMKY | || ##44 |. ..... ..... ..... ....* ..| STKY | || ##45 |. ..... ..... ..... ....* ..| CBKKY | || ##46 |. ..... ..... ..... ....* ..| CONSKY | || ##47 |. ..... ..... ..... ....* ..| DNDKY | || ##48 |. ..... ..... ..... ....* ..| EXHOLDKY | || ##49 |. ..... ..... ..... ....* ..| HOLDKY | |------------------------------------------------------------------------------| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |-----------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| ##50 |. ..... ..... ..... ....* ..| IUSEKY | || ##51 |. ..... ..... ..... ....* ..| LNRKY | || ##52 |. ..... ..... ..... ....* ..| PRIVKY | || ##53 |. ..... ..... ..... ....* ..| RLSKY | || ##54 |. ..... ..... ..... ....* ..| SNRKY | || ##55 |. ..... ..... ..... ....* ..| TRNSKY | || ##56 |. ..... ..... ..... ....* ..| RCTOFFKY | || ##57 |. ..... ..... ..... ....* ..| TOGGLEKY | |------------------------------------------------------------------------------------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| 0 |. ..... *.... ..... ..... ..| ATNDDID | || 0 |. ....* ..*** **... ..... ..| ATND | || 150 |. .**** ***** **... ..... ..| OWNNODE | || 31 |. .**** ***** **... ..... ..| TIE | || 37 - 38 |. .**** ***** **... ..... ..| TIE | || 40 |. .**** ***** **... ..... ..| TIE | || 702 |. .**** ***** **... ..... ..| TIE | || 9 |. .**** ..*** **... ..... ..| CO | || *0 |. *.... ..*.. ....* ..... ..| ACBK | || *10 |. ....* ....* **... ..... ..| CCMANS | R || *11 |. ....* ..... ....* ..... ..| AFWDVCE | || *12 |. ....* ..... ....* ..... ..| AFWDDTE | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *13 |. ....* ..... ..... ..... ..| AFWDDWD | || *14 |. .**** ***** **..* ..... ..| AFWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || *15 |. *...* ..**. ..... ..... ..| APRIV | || *16 |. ....* ..... ..... ..... ..| PUGDIS | || *17 |. *.... ..**. ..... ..... .*| SPLIT | || *18 |. *.... ..**. ..... ..... ..| TRACE | || *19 |. ....* ..... ....* ..... ..| AREM | || *20 |. ...** ..... ..... ..... ..| NOPT | || *21 |. ....* ..... ....* ..... ..| AFFWDVCE | || *22 |. ....* ..... ....* ..... ..| AFFWDDTE | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *23 |. *...* ..**. ..... ..... ..| CALLPARK | || *24 |. ....* ..**. ..... ..... ..| DISUON | || *3 |. .**** ..**. ..... ..... ..| PUDIR | || *40 |. ....* ....* **... ..... ..| CCANS | R || *41 |. ..... ..... ..... ..*.. ..| CCDIS | || *43 |. .**.* *...* **... ..... ..| DTE | || *44 |. .**** ***** **..* ..... ..| FWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || *45 |. ..... ..... ..... ..*.. ..| CCMEETME | || *46 |. ***** *.*** **... ..... ..| CCSCD | R || *47 |. ..... ..... ..... ..*.. ..| CCSURG | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *48 |. ..... ..... ..... ..*.. ..| CCVCE | || *49 |. ....* ..... ..... ..... ..| ACOSX | || *50 |. ....* ..**. ..... ..... ..| FWDIGNOR | || *51 |. ....* ..... ..... ..... ..| ADND | || *52 |. ....* ..... ..... ..... ..| AHTVCE | || *53 |. ***** *.*** **... ..... ..| CCMSURG | R || *54 |. ....* ..... ..... ..... ..| SPD | || *55 |. *...* ..**. ..... ..... ..| BABYLSNG | || *56 |. ***** *.*** **... ..... ..| CCMS | R || *57 |. ..... ..... ..... ..*.. ..| CCS | || *58 |. ***** *.*** **... ..... ..| CCSN | R || *59 |. ..... ..... ..... ..*.. ..| CCSTN | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *60 |. *.... ..... ..... ..... ..| KNOVR | || *61 |. .**** ..*** **... ..... ..| SPDC1 | || *62 |. .**** ..*** **... ..... ..| SPDC2 | || *63 |. .**.* ..**. ..... ..... ..| SPDI | || *64 |. ....* ..... ....* ..... ..| SPDIPROG | || *69 |. *.... ..**. ..... ..... ..| EOVR | || *7 |. *...* ..**. ..... ..... .*| LNR | || *81 |. ....* ..**. ..... .*... ..| APIN1 | || *82 |. ....* ..**. ..... .*... ..| APIN2 | || *83 |. ....* ..**. ..... .*... ..| APIN3 | || *84 |. ....* ..**. ..... .*... ..| APIN4 | || *85 |. ....* ..**. ..... .*... ..| APIN5 | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *88 |. ...** ....* *.... ..... ..| CTLS | || *89 |. ..*.. *...* *.... ..... ..| TESTLN | || *9 |. *.... ..... ..... ..... ..| CONF3 | || ** |. ....* ..... ..... ..... ..| PU | || *#50 |. *...* ..**. ..... ..... .*| ACDLOGON | || *#51 |. *...* ..**. ..... ..... .*| ACDAV | || *#52 |. *...* ..**. ..... ..... .*| ACDWORK | || *#53 |. *...* ..**. ..... ..... .*| ACC | || *#54 |. ....* ..... ..... ..... ..| MONSLNT | || *#55 |. ....* ..... ..... ..... ..| MONTONE | || *#60 |. *...* ..**. ..... ..... ..| ACDPGS | || *#61 |. *...* ..**. ..... ..... ..| ACDPQS | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| *#62 |. ....* ..... ..... ..... ..| ACDEMMSG | || *#63 |. ....* ..... ..... ..... ..| ACDSHMSG | || *#71 |. *...* ..**. ..... ..... ..| CAFAV | || *#72 |. *...* ..**. ..... ..... ..| CAFGRAV | || *#74 |. *...* ..**. ..... ..... ..| CAFAFWD | || #0 |. ....* ..... ..... ..... ..| DCBK | || #11 |. ....* ..... ..... ..... ..| DFWDVCE | || #12 |. ....* ..... ..... ..... ..| DFWDDTE | || #14 |. .**** ***** **..* ..... ..| DFWDREM | || | | |CFREMVAR CFU || | | |CFREMSE VOICE || #15 |. *...* ..**. ..... ..... ..| DPRIV | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| #19 |. ....* ..... ..... ..... ..| DREM | || #21 |. ....* ..... ..... ..... ..| DFFWDVCE | || #22 |. ....* ..... ..... ..... ..| DFFWDDTE | || #24 |. ....* ..**. ..... ..... ..| DISUOFF | || #49 |. ....* ..... ..... ..... ..| DCOSX | || #51 |. ....* ..... ..... ..... ..| DDND | || #52 |. ....* ..... ..... ..... ..| DHTVCE | || #74 |. ....* ..... ..... ..... ..| DIGIDAT | || #8 |. ....* ..**. ..... .*... ..| DPIN | || #92 |. ....* ....* ..... ..... ..| MBOFF | || #*50 |. *...* ..**. ..... ..... .*| ACDLOGOF | || #*51 |. *...* ..**. ..... ..... .*| ACDNAV | |------------------------------------------------------------------------------| DIGIT INTERPRETATION DPLN 0 |------------------------------------------------------------------------------| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT || CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO || |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |------------------------------------------------------------------------------| #*60 |. *...* ..**. ..... ..... ..| ACDSGS | || #*61 |. *...* ..**. ..... ..... ..| ACDSQS | || #*70 |. *...* ..**. ..... ..... ..| CAFLOGOF | || #*71 |. *...* ..**. ..... ..... ..| CAFNAV | || #*72 |. *...* ..**. ..... ..... ..| CAFGRNAV | || #*73 |. *...* ..**. ..... ..... ..| CAFGROFF | || #*74 |. *...* ..**. ..... ..... ..| CAFDFWD | || ##1 |. ..... ..... ....* ..... ..| KYPROG | || ##40 |. ..... ..... ..... ....* ..| NAKYLO | || ##7 |. ....* ....* ..... ..... ..| MBON | || ##8 |. ....* ....* ..... ..... ..| MBOFF | |------------------------------------------------------------------------------AMO-WABE -107 DIALLING PLANS, FEATURE ACCESS CODESDISPLAY COMPLETED;<dis-ldplnTYPE = ldpM40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERSLDPNO = 47;DIS-LDPLN:LDP,47;H500: AMO LDPLN STARTED+--------------+------------------------------------------+| | || LDPNO : 47 | LDP : 37-XXXX || | SPC : 22 |+--------------+------+------+------++------+------+------+| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|| +------+------+------++------+------+------+| | 0 | 37 | 1 || 8 | | || | 1 | | || 9 | | || | 2 | | || 10 | | || | 3 | | || 11 | | || | 4 | | || 12 | | || | 5 | | || 13 | | || | 6 | | || 14 | | || | 7 | | || 15 | | |+--------------+------+------+------++------+------+------+AMO-LDPLN-107 ADMINISTRATION LCR DIALPLANDISPLAY COMPLETED;Overlap Sending Dial Plan (DPLN)<dis-ldplnTYPE = ldpM40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERSLDPNO = 47;DIS-LDPLN:LDP,47;H500: AMO LDPLN STARTED+--------------+------------------------------------------+| | || LDPNO : 47 | LDP : 37-X || | SPC : 6 |+--------------+------+------+------++------+------+------+| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|| +------+------+------++------+------+------+| | 0 | 37 | 1 || 8 | | || | 1 | | || 9 | | || | 2 | | || 10 | | || | 3 | | || 11 | | || | 4 | | || 12 | | || | 5 | | || 13 | | || | 6 | | || 14 | | || | 7 | | || 15 | | |+--------------+------+------+------++------+------+------+AMO-LDPLN-196 ADMINISTRATION LCR DIALPLANDISPLAY COMPLETED;Step 2.
Add the new trunk board using BCSU.
<dis-bcsuTYPE = tblLTG = 1LTU = 1SLOT = 73;DIS-BCSU:TBL,1,1,73;H500: AMO BCSU STARTEDADDRESS : LTG 1 LTU 1-----+-----------+---------+---+---+-+------------+-----+--------+------------+| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |-----+-----------+---------+---+---+-+------------+-----+--------+------------+73 | Q2196-X DIU-N2 1 A | | Q2196-X | 1 | -04 - | READY |AMO-BCSU -107 BOARD CONFIGURATION, SWITCHING UNITDISPLAY COMPLETED;Step 3.
Configure Class of Trunk using COT.
<dis-cotCOTNO = 4;DIS-COT:4;H500: AMO COT STARTEDCOT: 4 INFO: 4:Q931 EXTERNALDEVICE: INDEP SOURCE: DBPARAMETER:PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRIRECALL IF USER HANGS UP IN CONSULTATION CALL RCLTRUNK CALL TRANSFER XFERTRUNK SIGNALING ANSWER ANSCHANGEOVER FROM HOLD TO RING TONE CHRTKNOCKING OVERRIDE POSSIBLE KNORCALL EXTEND FOR BUSY, RING OR CALL STATE CEBCNETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBNNETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFNDON'T RELEASE CALL TO BUSY HUNT GROUP BSHTSEND NO NODE NUMBER TO PARTNER LWNCINCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCRTSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCSINCOMING CDR BY ZONE OR FROM LINE ICZLINCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRDINTERWORKING CALLBACK - NO ANSWER AND MAILBOX CALLBACK IWCBAOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCCCONTROLLED TRUNK AND LINE SELECTION CTLSNO TONE NTONAMO-COT -107 CLASS OF TRUNK FOR CALL PROCESSINGDISPLAY COMPLETED;Step 4.
Configure Class of Parameter for device handler using COP.
<dis-copCOPNO = 4;DIS-COP:4;H500: AMO COP STARTEDCOP: 4 INFO: 4:Q931DEVICE: INDEP SOURCE: DBPARAMETER:SPECIAL MODE SFRMREGISTRATION OF LAYER 3 ADVISORIES L3ARAMO-COP -107 CLASS OF PARAMETER FOR DEVICE HANDLERDISPLAY COMPLETED;Step 5.
Configure Class of Service using COSSU.
<dis-cossuTYPE = cosCOS = 32;DIS-COSSU:COS,32;H500: AMO COSSU STARTED+------+----------+---------+---------+---------+----------+| COS | VOICE | FAX | TTX | VTX | DTE |+------+----------+---------+---------+---------+----------+| 32 |>32:TRUNKS || | TA | NOCO | NOCO | NOCO | TA || | TNOTCR | NOTIE | NOTIE | NOTIE | TNOTCR || | | | | | BASIC || | | | | | MSN || | | | | | CDRINT || | | | | | MULTRA || | | | | | |+------+----------+---------+---------+---------+----------+AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNITDISPLAY COMPLETED;<dis-cossuTYPE = lcosLCOS = 31;DIS-COSSU:LCOS,31;H500: AMO COSSU STARTEDTHE LCR CLASSMARKS ARE CONTAINED IN THE FOLLOWING LCOS:+----+-----------------------------------------------------------------+|LCOS| LCOSV | LCOSD || |12345678901234567890123456789012|12345678901234567890123456789012|| |>SERVICE INFORMATION |+----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+| 31| XX| XX|+----+-----------------------------------------------------------------+AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNITDISPLAY COMPLETEDStep 6.
Add the new trunk group access code using BUEND.
<dis-buendTGRP = 37FORMAT = ;DIS-BUEND:37,;H500: AMO BUEND STARTED+------------------------------- FORMAT = L -----------------------------------+| TGRP NUMBER : 37 TGRP NAME : PRI MAXIMUM NO. : 30 || SUBGROUP NO.: 10 DEVICE TYPE : S2CONN TRACENO : 0 || RESERVED : N SEARCH MODE : CIRCULAR ACD THRESHOLD : * || NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 1 || THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |+------------------------------------------------------------------------------+| 1- 1- 73-0 B-CHL: 1 | 1- 1- 73-0 B-CHL: 2 | 1- 1- 73-0 B-CHL: 3 || 1- 1- 73-0 B-CHL: 4 | 1- 1- 73-0 B-CHL: 5 | 1- 1- 73-0 B-CHL: 6 || 1- 1- 73-0 B-CHL: 7 | 1- 1- 73-0 B-CHL: 8 | 1- 1- 73-0 B-CHL: 9 || 1- 1- 73-0 B-CHL: 10 | 1- 1- 73-0 B-CHL: 11 | 1- 1- 73-0 B-CHL: 12 || 1- 1- 73-0 B-CHL: 13 | 1- 1- 73-0 B-CHL: 14 | 1- 1- 73-0 B-CHL: 15 || 1- 1- 73-0 B-CHL: 16 | 1- 1- 73-0 B-CHL: 17 | 1- 1- 73-0 B-CHL: 18 || 1- 1- 73-0 B-CHL: 19 | 1- 1- 73-0 B-CHL: 20 | 1- 1- 73-0 B-CHL: 21 || 1- 1- 73-0 B-CHL: 22 | 1- 1- 73-0 B-CHL: 23 | 1- 1- 73-0 B-CHL: 24 || 1- 1- 73-0 B-CHL: 25 | 1- 1- 73-0 B-CHL: 26 | 1- 1- 73-0 B-CHL: 27 || 1- 1- 73-0 B-CHL: 28 | 1- 1- 73-0 B-CHL: 29 | 1- 1- 73-0 B-CHL: 30 |+------------------------------------------------------------------------------+AMO-BUEND-107 TRUNK GROUPDISPLAY COMPLETED;Step 7.
Configure trunk using TDCSU.
(NETWORK/Master Side)<dis-tdcsuPEN1 = 1-1-73-0;DIS-TDCSU:1-1-73-0;H500: AMO TDCSU STARTED+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+| DEV = S2CONN PEN = 1-01-073-0 ||---------------------------------------------------------------------------|| COTNO = 4 COPNO = 4 DPLN = 0 || ITR = 0 COS = 32 LCOSV = 31 || LCOSD = 31 CCT = PRI DESTNO = 99 || PROTVAR = ETSI SEGMENT = 1 TCHARG = N || SUPPRESS = 0 DGTPR = CHIMAP = N || ISDNCC = ISDNAC = ISDNLC = || ISDNIP = ISDNNP = || PNPL2C = PNPL1C = PNPLC = || PNPL2P = PNPL1P = PNPAC = || TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 || ALARMNO = 2 FIDX = 1 CARRIER = 1 || ZONE = EMPTY COTX = 4 FWDX = 10 || DOMTYPE = DOMAINNO = TPROFNO = || INIGHT = || CCHDL = UUSCCX = 16 UUSCCY = 8 ||---------------------------------------------------------------------------|| TGRP = 37 SRCHMODE = CIR BCNEG = N || BCGR = 1 INS = Y LWPAR = 4 || LWPP = 0 LWLT = 0 LWPS = 0 || LWR1 = 0 LWR2 = 0 || BCHAN 1 && 30 || |+---------------------------------------------------------------------------+AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKSDISPLAY COMPLETED;<dis-lwparINFOPAT = 4FORMAT = lDEV = ;DIS-LWPAR:4,L,;H500: AMO LWPAR STARTED+-----------------------------------------------------------------------+| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 4 |+-----------------------------------------------------------------------+| LNTYPE = COPPER VERSION = S2 QUAL = ON || MASTER = Y DCHAN1 = 16 DCHAN2 = 0 || PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. || SMD = Y PERMACT = Y FCBAB = DFH || CDG = Y FIXEDTEI = 0 CNTRNR = 255 || TEIVERIF = N CRC4REP = N || DEV = INDEP || INFO = 4:COPPER-MASTER CLOCK(DPNSS A-END) |+-----------------------------------------------------------------------+AMO-LWPAR-70 LOADWARE PARAMETERS FOR NETWORKING MODULESDISPLAY COMPLETED;(USER/Slave Side)<dis-tdcsuPEN1 = 1-1-73-0;DIS-TDCSU:1-1-73-0;H500: AMO TDCSU STARTED+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+| DEV = S2CONN PEN = 1-01-073-0 ||---------------------------------------------------------------------------|| COTNO = 4 COPNO = 4 DPLN = 0 || ITR = 0 COS = 32 LCOSV = 31 || LCOSD = 31 CCT = PRI DESTNO = 99 || PROTVAR = ETSI SEGMENT = 1 TCHARG = N || SUPPRESS = 0 DGTPR = CHIMAP = N || ISDNCC = ISDNAC = ISDNLC = || ISDNIP = ISDNNP = || PNPL2C = PNPL1C = PNPLC = || PNPL2P = PNPL1P = PNPAC = || TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 || ALARMNO = 2 FIDX = 1 CARRIER = 1 || ZONE = EMPTY COTX = 4 FWDX = 10 || DOMTYPE = DOMAINNO = TPROFNO = || INIGHT = || CCHDL = UUSCCX = 16 UUSCCY = 8 ||---------------------------------------------------------------------------|| TGRP = 37 SRCHMODE = CIR BCNEG = N || BCGR = 1 INS = Y LWPAR = 1 || LWPP = 0 LWLT = 0 LWPS = 0 || LWR1 = 0 LWR2 = 0 || BCHAN 1 && 30 || |+---------------------------------------------------------------------------+AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKSDISPLAY COMPLETED;DIS-LWPAR:1,L,;H500: AMO LWPAR STARTED+-----------------------------------------------------------------------+| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |+-----------------------------------------------------------------------+| LNTYPE = COPPER VERSION = S2 QUAL = ON || MASTER = N DCHAN1 = 16 DCHAN2 = 0 || PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. || SMD = N PERMACT = Y FCBAB = DFH || CDG = N FIXEDTEI = 0 CNTRNR = 255 || TEIVERIF = N CRC4REP = N || DEV = INDEP || INFO = 1:COPPER-DERIVE CLOCK FROM LINE(I421) |+-----------------------------------------------------------------------+AMO-LWPAR-104 LOADWARE PARAMETERS FOR NETWORKING MODULESDISPLAY COMPLETED;Step 8.
Configure Reference Clock using REFTA.
(NETWORK/Master Side)<dis-reftaTYPE = circuitPEN = 1-1-73-0;DIS-REFTA:CIRCUIT,1-1-73-0;H500: AMO REFTA STARTED+-------------------------------------------------------------------------+| R E F E R E N C E C L O C K C I R C U I T S |+--------------+---------+----------+------+--------+------+--------+-----+| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|| | | | | | | |BUT || | | | | | | |ASYN.|+--------------+---------+----------+------+--------+------+--------+-----+| 1- 1- 73- 0 | DIU-N2 | S2CONN | 0 | 15485 | N | X | N |+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLEDISPLAY COMPLETED;(USER/Slave Side)<dis-reftaTYPE = circuitPEN = 1-1-73-0;DIS-REFTA:CIRCUIT,1-1-73-0;H500: AMO REFTA STARTED+-------------------------------------------------------------------------+| R E F E R E N C E C L O C K C I R C U I T S |+--------------+---------+----------+------+--------+------+--------+-----+| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|| | | | | | | |BUT || | | | | | | |ASYN.|+--------------+---------+----------+------+--------+------+--------+-----+| 1- 1- 73- 0 | DIU-N2 | S2CONN | 11 | 15485 | N | X | N |+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLEDISPLAY COMPLETED;Step 9.
Configure trunk Least Cost Routing using LDAT + RICHT.
LDAT<dis-ldatTYPE = lcrLROUTE = 37;DIS-LDAT:LCR,37;H500: AMO LDAT STARTED+--------------------------------------------------------------------------+| LROUTE = 37 LDPLN NAME = PRI TEST SERVICE = ALL || TYPE = LCR DNNO OF ROUTE = 1 -1 -999 || SERVICE INFO = |+-------+-------+-------+-----+-----+----------+------------+----+---------+| | | | | | SCHEDULE | CARRIER |BAND| || LRTEL | LVAL | TGRP | ODR |LAUTH| ABCDEFGH | ZONE |WDTH| LATTR |+-------+-------+-------+-----+-----+----------+------------+----+---------+| 1 | 1 | 37 | 1 | 1 | ******** | 1 EMPTY | 1 | NONE |+-------+-------+-------+-----+-----+----------+------------+----+---------+AMO-LDAT -107 LCR-DIRECTIONSDISPLAY COMPLETED;RICHT<dis-richtMODE = lrteLRTE = 37;DIS-RICHT:LRTE,37;H500: AMO RICHT STARTED+---------------------------------------------------------------+| LRTE = 37 NAME = PRI TEST SRVC = ALL || DNNO = 1 -1 -999 || ROUTOPT = NO REROUT = YES PLB = NO FWDBL = NO || MFV: CNV=FIX DSP=WITHOUT TEXT= PULS=PP300 || ROUTENO = 4 BUGS = LIN MAINGROUP = 4 || INFO = |+---------------------------------------------------------------+| TGRP = 37 LDAT PRI SUBGROUP = 10 |+---------------------------------------------------------------+AMO-RICHT-107 TRUNK ROUTINGDISPLAY COMPLETED;Step 10.
Configure LCR Out-dial Rules using LODR
<dis-lodrODR = 1INFOPAT = ;DIS-LODR:1,;H500: AMO LODR STARTED+-------------------------------------------------------+| ODR POSITION CMD PARAMETER |+--------+----------------------------------------------+| 1 | 1 ECHO 2 || | 2 END |+--------+----------------------------------------------+|INFO:PSTN |+-------------------------------------------------------+H03: THE NEXT FREE ODR IS 3AMO-LODR -107 ADMINISTRATION OF LCR OUTDIAL RULESDISPLAY COMPLETED;<Configuring the Cisco CallManager
Figure 1
Configuring the MGCP (Cisco 3640) Gateway
Figure 2
Configuring ISDN PRI, continued
Figure 3
Route Pattern Configuration
Test Results
As shown in the diagram below, a Siemens Hicom 330 E was connected via an ISDN E1 PRI link to a Cisco 3640 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 3640 and the PBX.
.
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/VG200 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco VG200 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco VG200 Gateway with ISDN protocol type setting of PRI ISO QSIG E1 supports both protocol sides by selecting "Network/User" in the Protocol Side field when configuring the Gateway via CCM.
The "Network/user" or Master/Slave choice for the Siemens Hicom 330 E PBX is made by deactivating the B channels/D-channel (<dea-dssu). A change command is then issued to the Reference clock (<cha-refta) to get to the Master/Slave selection (Pri=0 for Master, 11 for slave). Now the trunk is changed (<cha-tdcsu) to get to Device type prompt (Dev=s2conn), (Bcgrp=1), and loadware parameters (Lwpar=1 for User, 4 for Network). The D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
.
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
Test Setup 2
Setup was as follows:
•
PBX1 configured as ETSI, emulates User
•
Cisco 3646 Gateway configured as primary-net5, emulates Network
.
The test results are the same as in previous section . Refer to Tables 1 through 6 for details.
Appendix A
Call Manager Software Release:
Call Manager Components Release
Siemens Hicom 330 E Software release
Software Release--------------------------------------------------------------------------------TERMINAL 1 L O G O N 01-10-15 11:36:52-------------------------------------------------------------------------------- <dis-dbcVERBOSE =DIS-DBC:;H500: AMO DBC STARTED+------------------------------------------------------------------------------+| SYSTEM CLASSIFICATION : SYSTEM 80 (H80 ) || HARDWARE ASSEMBLY : EXTENDED COMPACT CXE (CXE ) || DEVELOPMENT LINE : EUROPE DEVELOPMENT (H300) || OPERATING MODE : SIMPLEX || RESTART TYPE : SYM || HW-ARCHITECTURE : 330E || HW-ARCHITECTURE TYPE : 4 || || 'NO OF' HW VALUES || LTG'S : 1 LTU'S : 4 LOG.LINES : 8000 MTS BD /GSN: 1 || SIUP'S/LTU: 4 TMD24'S PER LTU: 4 PHYS.PORTS: 2688 HWY /MTS BD: 64 || HDLC /DCL : 5 PBC /DCL : 1 PBC'S : 17 || LOG. SIU LINES : 26 || LOG. CONF LINES : 35 || LOG. DCL LINES : 36 || DB DIMENSIONING-NAME : 350EMSTD CONF-TABLE VERSION: 1 || DB SUSY'S: || SWITCH NUMBER : L31900Q2999A00001 || LOCATION : CUSTOMER || BAPPL : 6ECXM48 || DBAPPL : 6ECXM48 || SYSTEM_ID : PKP091000 |+------------------------------------------------------------------------------+AMO-DBC -89 DATABASE CONFIGURATIONDISPLAY COMPLETED;DIS-VEGAS;H500: AMO VEGAS STARTEDSYSTEM NO. AMO APS NO. START USER STATUSSWU: L31900Q2999A00001 REGEN P30252B4200B00103 14.11.00 14:33 DAVE A FINISHEDADS: L31900Q2999A00001 REGEN P30252B4200A00103 14.11.00 14:35 DAVE A FINISHEDAMO-VEGAS-107 ADMIN. OF DATABASE GENERATION RUNS ON SUPPORT SYSTEMDISPLAY COMPLETED;<Cisco 3640 Router Configuration
MGCP_3640#sh ver
Cisco Internetwork Operating System SoftwareIOS (tm) 3600 Software (C3640-JS-M), Experimental Version 12.2(20020124:013600) [accheung-v122_xn_throttle.build 101]Copyright (c) 1986-2002 by cisco Systems, Inc.Compiled Wed 23-Jan-02 17:57 by accheungImage text-base: 0x60008948, data-base: 0x61608000ROM: System Bootstrap, Version 11.1(19)AA, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1)MGCP_3640 uptime is 1 hour, 40 minutesSystem returned to ROM by power-onSystem image file is "flash:c3640-js-mz"cisco 3640 (R4700) processor (revision 0x00) with 58368K/7168K bytes of memory.Processor board ID 10620494R4700 CPU at 100Mhz, Implementation 33, Rev 1.0Channelized E1, Version 1.0.Bridging software.X.25 software, Version 3.0.0.SuperLAT software (copyright 1990 by Meridian Technology Corp).TN3270 Emulation software.Primary Rate ISDN software, Version 1.1.2 Ethernet/IEEE 802.3 interface(s)55 Serial network interface(s)2 Channelized E1/PRI port(s)2 Channelized T1/PRI port(s)2 Voice FXO interface(s)2 Voice FXS interface(s)DRAM configuration is 64 bits wide with parity disabled.125K bytes of non-volatile configuration memory.16384K bytes of processor board System flash (Read/Write)16384K bytes of processor board PCMCIA Slot0 flash (Read/Write)Configuration register is 0x2102MGCP_3640#sh diagSlot 0:Combo 2E, 2W Port adapter, 4 portsPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware revision 1.2 Board revision B0Serial number 7687836 Part number 800-01171-04Test history 0x0 RMA number 00-00-00EEPROM format version 1EEPROM contents (hex):0x20: 01 1E 01 02 00 75 4E 9C 50 04 93 04 00 00 00 000x30: 58 00 00 00 98 02 28 17 FF FF FF FF FF FF FF FFSlot 1:High Density Voice Port adapterPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware Revision : 1.1Top Assy. Part Number : 800-03567-01Board Revision : F1Deviation Number : 0-0Fab Version : 02PCB Serial Number : JAB05080M1SRMA Test History : 00RMA Number : 0-0-0-0RMA History : 00EEPROM format version 4EEPROM contents (hex):0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 010x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 300x20: 35 30 38 30 4D 31 53 03 00 81 00 00 00 00 04 000x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FFWIC Slot 0:E1 (2 Port) Multi-Flex Trunk WAN Daughter CardHardware revision 1.0 Board revision B0Serial number 18779824 Part number 800-04479-01Test history 0x0 RMA number 00-00-00Connector type PCIEEPROM format version 1EEPROM contents (hex):0x20: 01 23 01 00 01 1E 8E B0 50 11 7F 01 00 00 00 000x30: 58 00 00 00 00 02 25 00 FF FF FF FF FF FF FF FFHDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyalaHDV memory size 524280 heap free 175065Slot 2:4 PORT Voice PM for MARs Port adapterPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware revision 1.1 Board revision C0Serial number 10689987 Part number 800-02491-02Test history 0x0 RMA number 00-00-00EEPROM format version 1EEPROM contents (hex):0x20: 01 65 01 01 00 A3 1D C3 50 09 BB 02 00 00 00 000x30: 60 00 00 00 98 11 22 17 FF FF FF FF FF FF FF FFWIC Slot 0:FXS Voice daughter card (2 port)Hardware revision 1.1 Board revision C0Serial number 11291019 Part number 800-02493-01Test history 0x0 RMA number 00-00-00Connector type Wan ModuleEEPROM format version 1EEPROM contents (hex):0x20: 01 0E 01 01 00 AC 49 8B 50 09 BD 01 00 00 00 000x30: 60 00 00 00 99 01 05 01 FF FF FF FF FF FF FF FFWIC Slot 1:FXO Voice daughter card (2 port)Hardware revision 1.1 Board revision C0Serial number 8421533 Part number 800-02495-01Test history 0x0 RMA number 00-00-00Connector type Wan ModuleEEPROM format version 1EEPROM contents (hex):0x20: 01 0D 01 01 00 80 80 9D 50 09 BF 01 00 00 00 000x30: 60 00 00 00 98 06 02 01 FF FF FF FF FF FF FF FFSlot 3:High Density Voice Port adapterPort adapter is analyzedPort adapter insertion time unknownEEPROM contents at hardware discovery:Hardware Revision : 1.0Top Assy. Part Number : 800-03567-01Board Revision : A0Deviation Number : 0-0Fab Version : 02PCB Serial Number : JAB03350B9KRMA Test History : 00RMA Number : 0-0-0-0RMA History : 00EEPROM format version 4EEPROM contents (hex):0x00: 04 FF 40 00 CC 41 01 00 C0 46 03 20 00 0D EF 010x10: 42 41 30 80 00 00 00 00 02 02 C1 8B 4A 41 42 300x20: 33 33 35 30 42 39 4B 03 00 81 00 00 00 00 04 000x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FFWIC Slot 0:T1 (2 Port) Multi-Flex Trunk (Drop&Insert) WAN Daughter CardHardware revision 1.0 Board revision A0Serial number 19621702 Part number 800-04614-02Test history 0x0 RMA number 00-00-00Connector type PCIEEPROM format version 1EEPROM contents (hex):0x20: 01 24 01 00 01 2B 67 46 50 12 06 02 00 00 00 000x30: 50 00 00 00 00 05 20 00 FF FF FF FF FF FF FF FFHDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyalaHDV memory size 524280 heap free 175065MGCP_3640#sh controller e1E1 1/0 is up.Applique type is Channelized E1 - balancedNo alarms detected.alarm-trigger is not setVersion info Firmware: 20010315, FPGA: 15Framing is CRC4, Line Code is HDB3, Clock Source is Line.Data in current interval (11 seconds elapsed):0 Line Code Violations, 0 Path Code Violations0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail SecsE1 1/1 is down.Applique type is Channelized E1 - balancedFar End Block Errors DetectedReceiver has loss of signal.alarm-trigger is not setVersion info Firmware: 20010315, FPGA: 15Framing is CRC4, Line Code is HDB3, Clock Source is Line.Data in current interval (12 seconds elapsed):0 Line Code Violations, 0 Path Code Violations0 Slip Secs, 12 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 12 Unavail SecsMGCP_3640# sh confUsing 2266 out of 129016 bytes!version 12.2no parser cacheno service single-slot-reload-enableservice timestamps debug uptimeservice timestamps log uptimeno service password-encryptionno service dhcp!hostname MGCP_3640!logging rate-limit console 10 except errors!!!voice-card 1!voice-card 3!ip subnet-zero!!!no ip dhcp-client network-discoverymgcpmgcp call-agent 10.1.1.2 2427 service-type mgcp version 0.1mgcp dtmf-relay voip codec all mode out-of-bandmgcp rtp unreachable timeout 1000 action notifymgcp modem passthrough voip mode ciscomgcp sdp simplemgcp package-capability rtp-packagemgcp package-capability sst-packageno mgcp timer receive-rtcpno mgcp explicit hookstateisdn switch-type primary-nicall rsvp-sync!!!!!ccm-manager mgcpccm-manager music-on-holdccm-manager config server 10.1.1.2ccm-manager config!!controller E1 1/0pri-group timeslots 1-31 service mgcp!controller E1 1/1!controller T1 3/0framing esflinecode b8zspri-group timeslots 1-24 service mgcp!controller T1 3/1framing sflinecode ami!!!interface Ethernet0/0ip address 10.1.1.200 255.255.255.0no ip mroute-cachehalf-duplex!interface Ethernet0/1ip address 171.69.231.23 255.255.255.0no ip mroute-cachehalf-duplex!interface Serial1/0:15no ip addressno logging event link-statusisdn switch-type primary-net5isdn incoming-voice voiceisdn T310 4000isdn bind-l3 ccm-managerno cdp enable!interface Serial3/0:23no ip addressno logging event link-statusisdn switch-type primary-niisdn protocol-emulate networkisdn incoming-voice voiceisdn T306 30000isdn T310 40000isdn bind-l3 ccm-managerno cdp enable!ip classlessno ip http server!!!!snmp-server manager!voice-port 1/0:15!voice-port 2/0/0!voice-port 2/0/1!voice-port 2/1/0!voice-port 2/1/1!voice-port 3/0:23!dial-peer cor custom!!!dial-peer voice 1 potsapplication mgcp!dial-peer voice 3 potsapplication mgcpappport 2/0/1!dial-peer voice 2 potsapplication mgcpappport 2/0/0!dial-peer voice 999200 potsapplication mgcpappport 2/0/0!dial-peer voice 9991015 potsapplication mgcpappport 1/0:15!dial-peer voice 9993023 potsapplication mgcpappport 3/0:23!!line con 0line aux 0line vty 0 4login!!endMGCP_3640#sh runBuilding configuration...Current configuration : 2266 bytes!version 12.2no parser cacheno service single-slot-reload-enableservice timestamps debug uptimeservice timestamps log uptimeno service password-encryptionno service dhcp!hostname MGCP_3640!logging rate-limit console 10 except errors!!!voice-card 1!voice-card 3!ip subnet-zero!!!no ip dhcp-client network-discoverymgcpmgcp call-agent 10.1.1.2 2427 service-type mgcp version 0.1mgcp dtmf-relay voip codec all mode out-of-bandmgcp rtp unreachable timeout 1000 action notifymgcp modem passthrough voip mode ciscomgcp sdp simplemgcp package-capability rtp-packagemgcp package-capability sst-packageno mgcp timer receive-rtcpno mgcp explicit hookstateisdn switch-type primary-nicall rsvp-sync!!!!!ccm-manager mgcpccm-manager music-on-holdccm-manager config server 10.1.1.2ccm-manager config!!controller E1 1/0pri-group timeslots 1-31 service mgcp!controller E1 1/1!controller T1 3/0framing esflinecode b8zspri-group timeslots 1-24 service mgcp!controller T1 3/1framing sflinecode ami!!!interface Ethernet0/0ip address 10.1.1.200 255.255.255.0no ip mroute-cachehalf-duplex!interface Ethernet0/1ip address 171.69.231.23 255.255.255.0no ip mroute-cachehalf-duplex!interface Serial1/0:15no ip addressno logging event link-statusisdn switch-type primary-net5isdn incoming-voice voiceisdn T310 4000isdn bind-l3 ccm-managerno cdp enable!interface Serial3/0:23no ip addressno logging event link-statusisdn switch-type primary-niisdn protocol-emulate networkisdn incoming-voice voiceisdn T306 30000isdn T310 40000isdn bind-l3 ccm-managerno cdp enable!ip classlessno ip http server!!!!snmp-server manager!voice-port 1/0:15!voice-port 2/0/0!voice-port 2/0/1!voice-port 2/1/0!voice-port 2/1/1!voice-port 3/0:23!dial-peer cor custom!!!dial-peer voice 1 potsapplication mgcp!dial-peer voice 3 potsapplication mgcpappport 2/0/1!dial-peer voice 2 potsapplication mgcpappport 2/0/0!dial-peer voice 999200 potsapplication mgcpappport 2/0/0!dial-peer voice 9991015 potsapplication mgcpappport 1/0:15!dial-peer voice 9993023 potsapplication mgcpappport 3/0:23!!line con 0line aux 0line vty 0 4login!!endMGCP_3640#
Posted: Thu Sep 6 13:20:00 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.