cc/td/doc/product/voice/c_callmg
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Application Note

Introduction

Network Topology

Cisco Systems Hardware and Software Requirements

PBX Hardware and Software Requirements

Features Supported

Key Features Supported

Key Features Not Supported

Limitations

Calling Name and Number feature.

Configuring the Siemens Hicom 330 E PBX

Siemens Hicom 330 E PBX Configuration Menus and Commands

Configuring the Cisco CallManager

Test Results

Layers 2 & 3 (Q.921 and Q.931)

User/Network Settings

Appendix A

Call Manager Components Release

Siemens Hicom 330 E Software release

Cisco 3640 Router Configuration


Application Note


Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 3640-E1 MGCP Gateway

This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager the 3640-E1 PRI as the MGCP Gateway.

Introduction

The Network Topology diagram shows the test set-up for end-to-end interoperability between the Cisco CallManager connected to the PBX via 3640-E1 link as MGCP Gateway.

Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E PBX.

CallManager fails to return the "Connected Number" in the Connect message.

Connectivity is achieved by using the industry standard ETSI protocol. The Siemens Hicom 330 E can be configured as either NETWORK (Master) or USER (Slave) side.

Network Topology

Figure 1 Basic Setup

Cisco Systems Hardware and Software Requirements

Cisco 3640 Gateway with 2MFT E1 Port

Cisco Cat6K switch

Cisco CallManager 3.2

IOS software releases "c3640-js-mz.122-2.XN

PBX Hardware and Software Requirements

Hardware: DIU-N2

Software: Version 3.1

Features Supported

Key Features Supported

Calling/Called Number

Key Features Not Supported

Connected Number

Limitations

Calling Name and Number feature.

Calling Name deliver and presentation features are not supported by the Siemens Hicom 330 E PBX.

When calling from Cisco 7960 IP phone to Siemens digital phone, both phones display Calling Number after the call is answered as expected.

When calling from Siemens digital phone to Cisco 7960 IP phone, the Cisco IP phone displays Connected Number after the call is answered. When calling from the Siemens phone, the Connected Number is not displayed on the Siemens phone. It displays the numbers being dialed instead (i.e. Access Code + extension number). It was verified using the an ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.

Configuring the Siemens Hicom 330 E PBX

Use the following steps to configure the Siemens Hicom 330 E PBX.


Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.

Step 2. Add the new trunk board using BCSU.

Step 3. Configure Class of Trunk using COT.

Step 4. Configure Class of Parameter for device handler using COP.

Step 5. Configure Class of Service using COSSU.

Step 6. Add the new trunk group access code using BUEND.

Step 7. Configure trunk using TDCSU.

Step 8. Configure Reference Clock using REFTA.

Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.

Step 10. Configure LCR Out-dial Rules using LODR.

Siemens Hicom 330 E PBX Configuration Menus and Commands


Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.

<dis-wabe

TYPE = gen

CD =

DPLN = 0;

DIS-WABE:GEN,,0;

H500: AMO WABE STARTED

------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 001 - 002 |* ..... ..... ..... ..... ..| NETRTE | |
| 11 |. ..... ..... ..... ....* ..| MBKY | |
| 3001 |. .**** ***** **... ..... ..| STN | R |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 3007 |. ..... ..... ..... ....* ..| MBKY | |
| 3007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 4100 - 4500 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 72 |
| | | |DNNO 1- 1-702 |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 5000 - 5007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 5008 - 5009 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 99 |
| | | |DNNO 1- 1- 99 |
| 5010 |. .**** *.*** **... ..... ..| ATNDIND | |
| 800 |. ..... *...* **... ..... ..| ATNDDID | |
| 854 |. .**** ***** **... ..... ..| NETW | R |
| | | |DESTNO 2 |
| | | |DNNO 0- 0- 0 |
| *66 |. ....* ..... ..... ..... ..| SIGNON | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *91 |. ....* ....* ..... ..... ..| MBOFF | |
| #66 |. ....* ..... ..... ..... ..| SIGNOFF | |
| #91 |. ....* ....* ..... ..... ..| MBON | |
| ##22 |. ..... ..... ..... ....* ..| DAKY | |
| ##24 |. ..... ..... ..... ....* ..| DSSKY | |
| ##25 |. ..... ..... ..... ....* ..| FWDKY | |
| ##26 |. ..... ..... ..... ....* ..| HTKY | |
| ##27 |. ..... ..... ..... ....* ..| KNOVRKY | |
| ##28 |. ..... ..... ..... ....* ..| MBKY | |
| ##29 |. ..... ..... ..... ....* ..| MSGRKY | |
| ##35 |. ..... ..... ..... ....* ..| TIMEKY | |
| ##36 |. ..... ..... ..... ....* ..| VCKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##37 |. ..... ..... ..... ....* ..| VCRKY | |
| ##38 |. ..... ..... ..... ....* ..| CCKY | |
| ##39 |. ..... ..... ..... ....* ..| CONFKY | |
| ##41 |. ..... ..... ..... ....* ..| NAMEKY | |
| ##42 |. ..... ..... ..... ....* ..| PARKKY | |
| ##43 |. ..... ..... ..... ....* ..| REMKY | |
| ##44 |. ..... ..... ..... ....* ..| STKY | |
| ##45 |. ..... ..... ..... ....* ..| CBKKY | |
| ##46 |. ..... ..... ..... ....* ..| CONSKY | |
| ##47 |. ..... ..... ..... ....* ..| DNDKY | |
| ##48 |. ..... ..... ..... ....* ..| EXHOLDKY | |
| ##49 |. ..... ..... ..... ....* ..| HOLDKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
-----------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##50 |. ..... ..... ..... ....* ..| IUSEKY | |
| ##51 |. ..... ..... ..... ....* ..| LNRKY | |
| ##52 |. ..... ..... ..... ....* ..| PRIVKY | |
| ##53 |. ..... ..... ..... ....* ..| RLSKY | |
| ##54 |. ..... ..... ..... ....* ..| SNRKY | |
| ##55 |. ..... ..... ..... ....* ..| TRNSKY | |
| ##56 |. ..... ..... ..... ....* ..| RCTOFFKY | |
| ##57 |. ..... ..... ..... ....* ..| TOGGLEKY | |
------------------------------------------------------------------------------
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 0 |. ..... *.... ..... ..... ..| ATNDDID | |
| 0 |. ....* ..*** **... ..... ..| ATND | |
| 150 |. .**** ***** **... ..... ..| OWNNODE | |
| 31 |. .**** ***** **... ..... ..| TIE | |
| 37 - 38 |. .**** ***** **... ..... ..| TIE | |
| 40 |. .**** ***** **... ..... ..| TIE | |
| 702 |. .**** ***** **... ..... ..| TIE | |
| 9 |. .**** ..*** **... ..... ..| CO | |
| *0 |. *.... ..*.. ....* ..... ..| ACBK | |
| *10 |. ....* ....* **... ..... ..| CCMANS | R |
| *11 |. ....* ..... ....* ..... ..| AFWDVCE | |
| *12 |. ....* ..... ....* ..... ..| AFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *13 |. ....* ..... ..... ..... ..| AFWDDWD | |
| *14 |. .**** ***** **..* ..... ..| AFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *15 |. *...* ..**. ..... ..... ..| APRIV | |
| *16 |. ....* ..... ..... ..... ..| PUGDIS | |
| *17 |. *.... ..**. ..... ..... .*| SPLIT | |
| *18 |. *.... ..**. ..... ..... ..| TRACE | |
| *19 |. ....* ..... ....* ..... ..| AREM | |
| *20 |. ...** ..... ..... ..... ..| NOPT | |
| *21 |. ....* ..... ....* ..... ..| AFFWDVCE | |
| *22 |. ....* ..... ....* ..... ..| AFFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *23 |. *...* ..**. ..... ..... ..| CALLPARK | |
| *24 |. ....* ..**. ..... ..... ..| DISUON | |
| *3 |. .**** ..**. ..... ..... ..| PUDIR | |
| *40 |. ....* ....* **... ..... ..| CCANS | R |
| *41 |. ..... ..... ..... ..*.. ..| CCDIS | |
| *43 |. .**.* *...* **... ..... ..| DTE | |
| *44 |. .**** ***** **..* ..... ..| FWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *45 |. ..... ..... ..... ..*.. ..| CCMEETME | |
| *46 |. ***** *.*** **... ..... ..| CCSCD | R |
| *47 |. ..... ..... ..... ..*.. ..| CCSURG | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *48 |. ..... ..... ..... ..*.. ..| CCVCE | |
| *49 |. ....* ..... ..... ..... ..| ACOSX | |
| *50 |. ....* ..**. ..... ..... ..| FWDIGNOR | |
| *51 |. ....* ..... ..... ..... ..| ADND | |
| *52 |. ....* ..... ..... ..... ..| AHTVCE | |
| *53 |. ***** *.*** **... ..... ..| CCMSURG | R |
| *54 |. ....* ..... ..... ..... ..| SPD | |
| *55 |. *...* ..**. ..... ..... ..| BABYLSNG | |
| *56 |. ***** *.*** **... ..... ..| CCMS | R |
| *57 |. ..... ..... ..... ..*.. ..| CCS | |
| *58 |. ***** *.*** **... ..... ..| CCSN | R |
| *59 |. ..... ..... ..... ..*.. ..| CCSTN | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *60 |. *.... ..... ..... ..... ..| KNOVR | |
| *61 |. .**** ..*** **... ..... ..| SPDC1 | |
| *62 |. .**** ..*** **... ..... ..| SPDC2 | |
| *63 |. .**.* ..**. ..... ..... ..| SPDI | |
| *64 |. ....* ..... ....* ..... ..| SPDIPROG | |
| *69 |. *.... ..**. ..... ..... ..| EOVR | |
| *7 |. *...* ..**. ..... ..... .*| LNR | |
| *81 |. ....* ..**. ..... .*... ..| APIN1 | |
| *82 |. ....* ..**. ..... .*... ..| APIN2 | |
| *83 |. ....* ..**. ..... .*... ..| APIN3 | |
| *84 |. ....* ..**. ..... .*... ..| APIN4 | |
| *85 |. ....* ..**. ..... .*... ..| APIN5 | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *88 |. ...** ....* *.... ..... ..| CTLS | |
| *89 |. ..*.. *...* *.... ..... ..| TESTLN | |
| *9 |. *.... ..... ..... ..... ..| CONF3 | |
| ** |. ....* ..... ..... ..... ..| PU | |
| *#50 |. *...* ..**. ..... ..... .*| ACDLOGON | |
| *#51 |. *...* ..**. ..... ..... .*| ACDAV | |
| *#52 |. *...* ..**. ..... ..... .*| ACDWORK | |
| *#53 |. *...* ..**. ..... ..... .*| ACC | |
| *#54 |. ....* ..... ..... ..... ..| MONSLNT | |
| *#55 |. ....* ..... ..... ..... ..| MONTONE | |
| *#60 |. *...* ..**. ..... ..... ..| ACDPGS | |
| *#61 |. *...* ..**. ..... ..... ..| ACDPQS | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *#62 |. ....* ..... ..... ..... ..| ACDEMMSG | |
| *#63 |. ....* ..... ..... ..... ..| ACDSHMSG | |
| *#71 |. *...* ..**. ..... ..... ..| CAFAV | |
| *#72 |. *...* ..**. ..... ..... ..| CAFGRAV | |
| *#74 |. *...* ..**. ..... ..... ..| CAFAFWD | |
| #0 |. ....* ..... ..... ..... ..| DCBK | |
| #11 |. ....* ..... ..... ..... ..| DFWDVCE | |
| #12 |. ....* ..... ..... ..... ..| DFWDDTE | |
| #14 |. .**** ***** **..* ..... ..| DFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| #15 |. *...* ..**. ..... ..... ..| DPRIV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #19 |. ....* ..... ..... ..... ..| DREM | |
| #21 |. ....* ..... ..... ..... ..| DFFWDVCE | |
| #22 |. ....* ..... ..... ..... ..| DFFWDDTE | |
| #24 |. ....* ..**. ..... ..... ..| DISUOFF | |
| #49 |. ....* ..... ..... ..... ..| DCOSX | |
| #51 |. ....* ..... ..... ..... ..| DDND | |
| #52 |. ....* ..... ..... ..... ..| DHTVCE | |
| #74 |. ....* ..... ..... ..... ..| DIGIDAT | |
| #8 |. ....* ..**. ..... .*... ..| DPIN | |
| #92 |. ....* ....* ..... ..... ..| MBOFF | |
| #*50 |. *...* ..**. ..... ..... .*| ACDLOGOF | |
| #*51 |. *...* ..**. ..... ..... .*| ACDNAV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #*60 |. *...* ..**. ..... ..... ..| ACDSGS | |
| #*61 |. *...* ..**. ..... ..... ..| ACDSQS | |
| #*70 |. *...* ..**. ..... ..... ..| CAFLOGOF | |
| #*71 |. *...* ..**. ..... ..... ..| CAFNAV | |
| #*72 |. *...* ..**. ..... ..... ..| CAFGRNAV | |
| #*73 |. *...* ..**. ..... ..... ..| CAFGROFF | |
| #*74 |. *...* ..**. ..... ..... ..| CAFDFWD | |
| ##1 |. ..... ..... ....* ..... ..| KYPROG | |
| ##40 |. ..... ..... ..... ....* ..| NAKYLO | |
| ##7 |. ....* ....* ..... ..... ..| MBON | |
| ##8 |. ....* ....* ..... ..... ..| MBOFF | |
------------------------------------------------------------------------------

AMO-WABE -107 DIALLING PLANS, FEATURE ACCESS CODES

DISPLAY COMPLETED;

<dis-ldpln

TYPE = ldp

M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS

LDPNO = 47;

DIS-LDPLN:LDP,47;

H500: AMO LDPLN STARTED
+--------------+------------------------------------------+
| | |
| LDPNO : 47 | LDP : 37-XXXX |
| | SPC : 22 |
+--------------+------+------+------++------+------+------+
| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|
| +------+------+------++------+------+------+
| | 0 | 37 | 1 || 8 | | |
| | 1 | | || 9 | | |
| | 2 | | || 10 | | |
| | 3 | | || 11 | | |
| | 4 | | || 12 | | |
| | 5 | | || 13 | | |
| | 6 | | || 14 | | |
| | 7 | | || 15 | | |
+--------------+------+------+------++------+------+------+

AMO-LDPLN-107 ADMINISTRATION LCR DIALPLAN

DISPLAY COMPLETED;
Overlap Sending Dial Plan (DPLN)

<dis-ldpln

TYPE = ldp

M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS

LDPNO = 47;

DIS-LDPLN:LDP,47;

H500: AMO LDPLN STARTED
+--------------+------------------------------------------+
| | |
| LDPNO : 47 | LDP : 37-X |
| | SPC : 6 |
+--------------+------+------+------++------+------+------+
| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|
| +------+------+------++------+------+------+
| | 0 | 37 | 1 || 8 | | |
| | 1 | | || 9 | | |
| | 2 | | || 10 | | |
| | 3 | | || 11 | | |
| | 4 | | || 12 | | |
| | 5 | | || 13 | | |
| | 6 | | || 14 | | |
| | 7 | | || 15 | | |
+--------------+------+------+------++------+------+------+

AMO-LDPLN-196 ADMINISTRATION LCR DIALPLAN

DISPLAY COMPLETED;


Step 2. Add the new trunk board using BCSU.


<dis-bcsu


TYPE = tbl

LTG = 1

LTU = 1

SLOT = 73;

DIS-BCSU:TBL,1,1,73;

H500: AMO BCSU STARTED
ADDRESS : LTG 1 LTU 1
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
73 | Q2196-X DIU-N2 1 A | | Q2196-X | 1 | -04 - | READY |

AMO-BCSU -107 BOARD CONFIGURATION, SWITCHING UNIT

DISPLAY COMPLETED;


Step 3. Configure Class of Trunk using COT.

<dis-cot

COTNO = 4;

DIS-COT:4;
H500: AMO COT STARTED
COT: 4 INFO: 4:Q931 EXTERNAL
DEVICE: INDEP SOURCE: DB
PARAMETER:
PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRI
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
DON'T RELEASE CALL TO BUSY HUNT GROUP BSHT
SEND NO NODE NUMBER TO PARTNER LWNC
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
INCOMING CDR BY ZONE OR FROM LINE ICZL
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
INTERWORKING CALLBACK - NO ANSWER AND MAILBOX CALLBACK IWCB
AOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCC
CONTROLLED TRUNK AND LINE SELECTION CTLS
NO TONE NTON
AMO-COT -107 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;

Step 4. Configure Class of Parameter for device handler using COP.

<dis-cop

COPNO = 4;

DIS-COP:4;
H500: AMO COP STARTED
COP: 4 INFO: 4:Q931
DEVICE: INDEP SOURCE: DB
PARAMETER:
SPECIAL MODE SFRM
REGISTRATION OF LAYER 3 ADVISORIES L3AR

AMO-COP -107 CLASS OF PARAMETER FOR DEVICE HANDLER

DISPLAY COMPLETED;



Step 5. Configure Class of Service using COSSU.

<dis-cossu

TYPE = cos
COS = 32;
DIS-COSSU:COS,32;
H500: AMO COSSU STARTED

+------+----------+---------+---------+---------+----------+
| COS | VOICE | FAX | TTX | VTX | DTE |
+------+----------+---------+---------+---------+----------+
| 32 |>32:TRUNKS |
| | TA | NOCO | NOCO | NOCO | TA |
| | TNOTCR | NOTIE | NOTIE | NOTIE | TNOTCR |
| | | | | | BASIC |
| | | | | | MSN |
| | | | | | CDRINT |
| | | | | | MULTRA |
| | | | | | |
+------+----------+---------+---------+---------+----------+

AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT

DISPLAY COMPLETED;

<dis-cossu

TYPE = lcos
LCOS = 31;
DIS-COSSU:LCOS,31;
H500: AMO COSSU STARTED

THE LCR CLASSMARKS ARE CONTAINED IN THE FOLLOWING LCOS:

+----+-----------------------------------------------------------------+
|LCOS| LCOSV | LCOSD |
| |12345678901234567890123456789012|12345678901234567890123456789012|
| |>SERVICE INFORMATION |
+----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+
| 31| XX| XX|
+----+-----------------------------------------------------------------+


AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT

DISPLAY COMPLETED


Step 6. Add the new trunk group access code using BUEND.

<dis-buend

TGRP = 37

FORMAT = ;

DIS-BUEND:37,;
H500: AMO BUEND STARTED
+------------------------------- FORMAT = L -----------------------------------+
| TGRP NUMBER : 37 TGRP NAME : PRI MAXIMUM NO. : 30 |
| SUBGROUP NO.: 10 DEVICE TYPE : S2CONN TRACENO : 0 |
| RESERVED : N SEARCH MODE : CIRCULAR ACD THRESHOLD : * |
| NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 1 |
| THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 1- 73-0 B-CHL: 1 | 1- 1- 73-0 B-CHL: 2 | 1- 1- 73-0 B-CHL: 3 |
| 1- 1- 73-0 B-CHL: 4 | 1- 1- 73-0 B-CHL: 5 | 1- 1- 73-0 B-CHL: 6 |
| 1- 1- 73-0 B-CHL: 7 | 1- 1- 73-0 B-CHL: 8 | 1- 1- 73-0 B-CHL: 9 |
| 1- 1- 73-0 B-CHL: 10 | 1- 1- 73-0 B-CHL: 11 | 1- 1- 73-0 B-CHL: 12 |
| 1- 1- 73-0 B-CHL: 13 | 1- 1- 73-0 B-CHL: 14 | 1- 1- 73-0 B-CHL: 15 |
| 1- 1- 73-0 B-CHL: 16 | 1- 1- 73-0 B-CHL: 17 | 1- 1- 73-0 B-CHL: 18 |
| 1- 1- 73-0 B-CHL: 19 | 1- 1- 73-0 B-CHL: 20 | 1- 1- 73-0 B-CHL: 21 |
| 1- 1- 73-0 B-CHL: 22 | 1- 1- 73-0 B-CHL: 23 | 1- 1- 73-0 B-CHL: 24 |
| 1- 1- 73-0 B-CHL: 25 | 1- 1- 73-0 B-CHL: 26 | 1- 1- 73-0 B-CHL: 27 |
| 1- 1- 73-0 B-CHL: 28 | 1- 1- 73-0 B-CHL: 29 | 1- 1- 73-0 B-CHL: 30 |
+------------------------------------------------------------------------------+
AMO-BUEND-107 TRUNK GROUP

DISPLAY COMPLETED;


Step 7. Configure trunk using TDCSU.

(NETWORK/Master Side)
<dis-tdcsu

PEN1 = 1-1-73-0;

DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 4 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
AMO-TDCSU-107 DIGITAL TRUNKS

DISPLAY COMPLETED;

<dis-lwpar

INFOPAT = 4

FORMAT = l

DEV = ;

DIS-LWPAR:4,L,;

H500: AMO LWPAR STARTED

+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 4 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = Y DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = Y PERMACT = Y FCBAB = DFH |
| CDG = Y FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 4:COPPER-MASTER CLOCK(DPNSS A-END) |
+-----------------------------------------------------------------------+

AMO-LWPAR-70 LOADWARE PARAMETERS FOR NETWORKING MODULES

DISPLAY COMPLETED;
(USER/Slave Side)
<dis-tdcsu

PEN1 = 1-1-73-0;

DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 1 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
AMO-TDCSU-107 DIGITAL TRUNKS

DISPLAY COMPLETED;

DIS-LWPAR:1,L,;
H500: AMO LWPAR STARTED

+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = N DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = N PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 1:COPPER-DERIVE CLOCK FROM LINE(I421) |
+-----------------------------------------------------------------------+

AMO-LWPAR-104 LOADWARE PARAMETERS FOR NETWORKING MODULES

DISPLAY COMPLETED;


Step 8. Configure Reference Clock using REFTA.

(NETWORK/Master Side)
<dis-refta

TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;

H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 0 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+
AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;

(USER/Slave Side)
<dis-refta

TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;

H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 11 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+
AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;


Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.

LDAT
<dis-ldat

TYPE = lcr

LROUTE = 37;

DIS-LDAT:LCR,37;
H500: AMO LDAT STARTED
+--------------------------------------------------------------------------+
| LROUTE = 37 LDPLN NAME = PRI TEST SERVICE = ALL |
| TYPE = LCR DNNO OF ROUTE = 1 -1 -999 |
| SERVICE INFO = |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| | | | | | SCHEDULE | CARRIER |BAND| |
| LRTEL | LVAL | TGRP | ODR |LAUTH| ABCDEFGH | ZONE |WDTH| LATTR |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| 1 | 1 | 37 | 1 | 1 | ******** | 1 EMPTY | 1 | NONE |
+-------+-------+-------+-----+-----+----------+------------+----+---------+

AMO-LDAT -107 LCR-DIRECTIONS
DISPLAY COMPLETED;
RICHT
<dis-richt

MODE = lrte
LRTE = 37;
DIS-RICHT:LRTE,37;
H500: AMO RICHT STARTED
+---------------------------------------------------------------+
| LRTE = 37 NAME = PRI TEST SRVC = ALL |
| DNNO = 1 -1 -999 |
| ROUTOPT = NO REROUT = YES PLB = NO FWDBL = NO |
| MFV: CNV=FIX DSP=WITHOUT TEXT= PULS=PP300 |
| ROUTENO = 4 BUGS = LIN MAINGROUP = 4 |
| INFO = |
+---------------------------------------------------------------+
| TGRP = 37 LDAT PRI SUBGROUP = 10 |
+---------------------------------------------------------------+
AMO-RICHT-107 TRUNK ROUTING
DISPLAY COMPLETED;


Step 10. Configure LCR Out-dial Rules using LODR

<dis-lodr
ODR = 1
INFOPAT = ;
DIS-LODR:1,;
H500: AMO LODR STARTED
+-------------------------------------------------------+
| ODR POSITION CMD PARAMETER |
+--------+----------------------------------------------+
| 1 | 1 ECHO 2 |
| | 2 END |
+--------+----------------------------------------------+
|INFO:PSTN |
+-------------------------------------------------------+
H03: THE NEXT FREE ODR IS 3
AMO-LODR -107 ADMINISTRATION OF LCR OUTDIAL RULES
DISPLAY COMPLETED;
<

Configuring the Cisco CallManager

Figure 1

Configuring the MGCP (Cisco 3640) Gateway

Figure 2

Configuring ISDN PRI, continued

Figure 3

Route Pattern Configuration

Test Results

As shown in the diagram below, a Siemens Hicom 330 E was connected via an ISDN E1 PRI link to a Cisco 3640 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 3640 and the PBX.

.

Layers 2 & 3 (Q.921 and Q.931)

Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.

Layer 2 Q.921 packets were monitored to ensure that each PBX/VG200 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.

Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.

Telephone calls were made end-to-end in both directions through the Cisco VG200 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.

User/Network Settings

The Cisco VG200 Gateway with ISDN protocol type setting of PRI ISO QSIG E1 supports both protocol sides by selecting "Network/User" in the Protocol Side field when configuring the Gateway via CCM.

The "Network/user" or Master/Slave choice for the Siemens Hicom 330 E PBX is made by deactivating the B channels/D-channel (<dea-dssu). A change command is then issued to the Reference clock (<cha-refta) to get to the Master/Slave selection (Pri=0 for Master, 11 for slave). Now the trunk is changed (<cha-tdcsu) to get to Device type prompt (Dev=s2conn), (Bcgrp=1), and loadware parameters (Lwpar=1 for User, 4 for Network). The D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.

.

Table 1  PBX 1 - ETSI (Network) Cisco 3640 Gateway - primary-net5 (User)

Siemens Hicom 330 E Switch-type/ Protocol side setting
Cisco VG200 ISDN protocol-type/Protocol
side setting

ETSI/ Master

Isdn switch-type primary-net5

Isdn protocol-emulate user


Table 2  Basic Calls: (Enbloc Sending)

Calls Made
Call Comp?
"Calling Number" Displayed on Final Destination?
"Calling Name" Displayed on Final Destination?
"Called Number" Passed to Orig. Side?
"Called Name" Passed to Orig. Side?
Notes

Phone A to Phone C

Yes

Yes

No

No

No

1

Phone C to Phone A

Yes

Yes

No

No

No

 

1 CallManager is not sending "Connected Number" information in the connect message back to PBX.


Table 3  Call Transfers: (Supervised Local Transfers)

Calls Made
Call Comp?
Orig. "Calling Number" displayed on Final Dest. phone?
Orig. "Calling Name" displayed on Final Dest. phone?
"Called Number" display on Orig. phone updated after transfer?
"Called Name" display on Orig. phone updated after transfer?
Notes

Phone C to Phone A Xfr to Phone B

Yes

Yes

No

No

No

 

Phone A to Phone C Xfr to Phone D

Yes

Yes

No

No

No

 

Table 4  Call Conferencing (Local)

Calls Made
Call Comp?
"Calling Number" Passed to remaining conferee when the conferencing phone drops out?
"Calling Name" displayed on remaining conferee when the conferencing phone drops out?
"Connected Number" updated on Orig. Caller phone display when a conferee drops out?
"Connected Name" updated on Orig. Caller phone display when a conferee drops out?
Notes
Phone C to Phone A,
Phone A conf Phone B

Yes

(A Drops out) Yes

(A Drops out) No

(A Drops out) No

(A Drops out) No

 
Phone C to Phone A,
Phone C conf Phone D

Yes

(C Drops out) No

(C Drops out) No

(D Drops out) No

(D Drops out) No

 
Phone A to Phone C,
Phone C conf Phone D

Yes

(C Drops out) No

(C Drops out) No

(C Drops out) No

(C Drops out) No

 
Phone A to Phone C,
Phone A conf Phone B

Yes

(A Drops out) No

(A Drops out) No

(B Drops out) No

(B Drops out) No

 

Table 5  Call Forward (Local)

Calls Made
Call Comp?
Original "Calling Number" Passed to Final Dest.?
Original "Calling Name" Passed to Final Dest.?
Forwarding "Called Number" Pased to Final Dest.?
Forwarding "Called Name" Displayed on Final Dest.?
Final dest. "Connected Number" updated at orig. side?
Final dest. "ConnectedName" updated at orig. side?
Notes
Phone C to Phone A fwd to Phone B

Yes

Yes

No

No

No

No

No

 
Phone A to Phone C fwd to Phone D

Yes

Yes

No

No

No

No

No

 

Test Setup 2

Setup was as follows:

PBX1 configured as ETSI, emulates User

Cisco 3646 Gateway configured as primary-net5, emulates Network

.

Table 6  Switch and Gateway Settings

Siemens Hicom 330 E Switch-type/ Protocol side setting
Cisco 3640 ISDN protocol-type/Protocol
side setting

ETSO/Slave

isdn switch-type—primary-net5

isdn protocol—emulate network


The test results are the same as in previous section . Refer to Tables 1 through 6 for details.

Appendix A

Call Manager Software Release:

Call Manager Components Release

Siemens Hicom 330 E Software release


Software Release

--------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-10-15 11:36:52
-------------------------------------------------------------------------------- <dis-dbc

VERBOSE =
DIS-DBC:;
H500: AMO DBC STARTED
+------------------------------------------------------------------------------+
| SYSTEM CLASSIFICATION : SYSTEM 80 (H80 ) |
| HARDWARE ASSEMBLY : EXTENDED COMPACT CXE (CXE ) |
| DEVELOPMENT LINE : EUROPE DEVELOPMENT (H300) |
| OPERATING MODE : SIMPLEX |
| RESTART TYPE : SYM |
| HW-ARCHITECTURE : 330E |
| HW-ARCHITECTURE TYPE : 4 |
| |
| 'NO OF' HW VALUES |
| LTG'S : 1 LTU'S : 4 LOG.LINES : 8000 MTS BD /GSN: 1 |
| SIUP'S/LTU: 4 TMD24'S PER LTU: 4 PHYS.PORTS: 2688 HWY /MTS BD: 64 |
| HDLC /DCL : 5 PBC /DCL : 1 PBC'S : 17 |
| LOG. SIU LINES : 26 |
| LOG. CONF LINES : 35 |
| LOG. DCL LINES : 36 |
| DB DIMENSIONING-NAME : 350EMSTD CONF-TABLE VERSION: 1 |
| DB SUSY'S: |
| SWITCH NUMBER : L31900Q2999A00001 |
| LOCATION : CUSTOMER |
| BAPPL : 6ECXM48 |
| DBAPPL : 6ECXM48 |
| SYSTEM_ID : PKP091000 |
+------------------------------------------------------------------------------+
AMO-DBC -89 DATABASE CONFIGURATION
DISPLAY COMPLETED;


DIS-VEGAS;
H500: AMO VEGAS STARTED
SYSTEM NO. AMO APS NO. START USER STATUS
SWU: L31900Q2999A00001 REGEN P30252B4200B00103 14.11.00 14:33 DAVE A FINISHED
ADS: L31900Q2999A00001 REGEN P30252B4200A00103 14.11.00 14:35 DAVE A FINISHED
AMO-VEGAS-107 ADMIN. OF DATABASE GENERATION RUNS ON SUPPORT SYSTEM
DISPLAY COMPLETED;
<

Cisco 3640 Router Configuration

MGCP_3640#sh ver

Cisco Internetwork Operating System Software
IOS (tm) 3600 Software (C3640-JS-M), Experimental Version 12.2(20020124:013600) [accheung-v122_xn_throttle.build 101]
Copyright (c) 1986-2002 by cisco Systems, Inc.
Compiled Wed 23-Jan-02 17:57 by accheung
Image text-base: 0x60008948, data-base: 0x61608000

ROM: System Bootstrap, Version 11.1(19)AA, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1)

MGCP_3640 uptime is 1 hour, 40 minutes
System returned to ROM by power-on
System image file is "flash:c3640-js-mz"

cisco 3640 (R4700) processor (revision 0x00) with 58368K/7168K bytes of memory.
Processor board ID 10620494
R4700 CPU at 100Mhz, Implementation 33, Rev 1.0
Channelized E1, Version 1.0.
Bridging software.
X.25 software, Version 3.0.0.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
TN3270 Emulation software.
Primary Rate ISDN software, Version 1.1.
2 Ethernet/IEEE 802.3 interface(s)
55 Serial network interface(s)
2 Channelized E1/PRI port(s)
2 Channelized T1/PRI port(s)
2 Voice FXO interface(s)
2 Voice FXS interface(s)
DRAM configuration is 64 bits wide with parity disabled.
125K bytes of non-volatile configuration memory.
16384K bytes of processor board System flash (Read/Write)
16384K bytes of processor board PCMCIA Slot0 flash (Read/Write)

Configuration register is 0x2102




MGCP_3640#sh diag
Slot 0:
Combo 2E, 2W Port adapter, 4 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware revision 1.2 Board revision B0
Serial number 7687836 Part number 800-01171-04
Test history 0x0 RMA number 00-00-00
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 1E 01 02 00 75 4E 9C 50 04 93 04 00 00 00 00
0x30: 58 00 00 00 98 02 28 17 FF FF FF FF FF FF FF FF

Slot 1:
High Density Voice Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 1.1
Top Assy. Part Number : 800-03567-01
Board Revision : F1
Deviation Number : 0-0
Fab Version : 02
PCB Serial Number : JAB05080M1S
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 01
0x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 30
0x20: 35 30 38 30 4D 31 53 03 00 81 00 00 00 00 04 00
0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

WIC Slot 0:
E1 (2 Port) Multi-Flex Trunk WAN Daughter Card
Hardware revision 1.0 Board revision B0
Serial number 18779824 Part number 800-04479-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 23 01 00 01 1E 8E B0 50 11 7F 01 00 00 00 00
0x30: 58 00 00 00 00 02 25 00 FF FF FF FF FF FF FF FF

HDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyala
HDV memory size 524280 heap free 175065

Slot 2:
4 PORT Voice PM for MARs Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware revision 1.1 Board revision C0
Serial number 10689987 Part number 800-02491-02
Test history 0x0 RMA number 00-00-00
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 65 01 01 00 A3 1D C3 50 09 BB 02 00 00 00 00
0x30: 60 00 00 00 98 11 22 17 FF FF FF FF FF FF FF FF

WIC Slot 0:
FXS Voice daughter card (2 port)
Hardware revision 1.1 Board revision C0
Serial number 11291019 Part number 800-02493-01
Test history 0x0 RMA number 00-00-00
Connector type Wan Module
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 0E 01 01 00 AC 49 8B 50 09 BD 01 00 00 00 00
0x30: 60 00 00 00 99 01 05 01 FF FF FF FF FF FF FF FF

WIC Slot 1:
FXO Voice daughter card (2 port)
Hardware revision 1.1 Board revision C0
Serial number 8421533 Part number 800-02495-01
Test history 0x0 RMA number 00-00-00
Connector type Wan Module
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 0D 01 01 00 80 80 9D 50 09 BF 01 00 00 00 00
0x30: 60 00 00 00 98 06 02 01 FF FF FF FF FF FF FF FF

Slot 3:
High Density Voice Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 1.0
Top Assy. Part Number : 800-03567-01
Board Revision : A0
Deviation Number : 0-0
Fab Version : 02
PCB Serial Number : JAB03350B9K
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 CC 41 01 00 C0 46 03 20 00 0D EF 01
0x10: 42 41 30 80 00 00 00 00 02 02 C1 8B 4A 41 42 30
0x20: 33 33 35 30 42 39 4B 03 00 81 00 00 00 00 04 00
0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

WIC Slot 0:
T1 (2 Port) Multi-Flex Trunk (Drop&Insert) WAN Daughter Card
Hardware revision 1.0 Board revision A0
Serial number 19621702 Part number 800-04614-02
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 24 01 00 01 2B 67 46 50 12 06 02 00 00 00 00
0x30: 50 00 00 00 00 05 20 00 FF FF FF FF FF FF FF FF

HDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyala
HDV memory size 524280 heap free 175065

MGCP_3640#sh controller e1
E1 1/0 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
alarm-trigger is not set
Version info Firmware: 20010315, FPGA: 15
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (11 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
E1 1/1 is down.
Applique type is Channelized E1 - balanced
Far End Block Errors Detected
Receiver has loss of signal.
alarm-trigger is not set
Version info Firmware: 20010315, FPGA: 15
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (12 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 12 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 12 Unavail Secs


MGCP_3640# sh conf
Using 2266 out of 129016 bytes
!
version 12.2
no parser cache
no service single-slot-reload-enable
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
no service dhcp
!
hostname MGCP_3640
!
logging rate-limit console 10 except errors
!
!
!
voice-card 1
!
voice-card 3
!
ip subnet-zero
!
!
!
no ip dhcp-client network-discovery
mgcp
mgcp call-agent 10.1.1.2 2427 service-type mgcp version 0.1
mgcp dtmf-relay voip codec all mode out-of-band
mgcp rtp unreachable timeout 1000 action notify
mgcp modem passthrough voip mode cisco
mgcp sdp simple
mgcp package-capability rtp-package
mgcp package-capability sst-package
no mgcp timer receive-rtcp
no mgcp explicit hookstate
isdn switch-type primary-ni
call rsvp-sync
!
!
!
!
!
ccm-manager mgcp
ccm-manager music-on-hold
ccm-manager config server 10.1.1.2
ccm-manager config
!
!
controller E1 1/0
pri-group timeslots 1-31 service mgcp
!
controller E1 1/1
!
controller T1 3/0
framing esf
linecode b8zs
pri-group timeslots 1-24 service mgcp
!
controller T1 3/1
framing sf
linecode ami
!
!
!
interface Ethernet0/0
ip address 10.1.1.200 255.255.255.0
no ip mroute-cache
half-duplex
!
interface Ethernet0/1
ip address 171.69.231.23 255.255.255.0
no ip mroute-cache
half-duplex
!
interface Serial1/0:15
no ip address
no logging event link-status
isdn switch-type primary-net5
isdn incoming-voice voice
isdn T310 4000
isdn bind-l3 ccm-manager
no cdp enable
!
interface Serial3/0:23
no ip address
no logging event link-status
isdn switch-type primary-ni
isdn protocol-emulate network
isdn incoming-voice voice
isdn T306 30000
isdn T310 40000
isdn bind-l3 ccm-manager
no cdp enable
!
ip classless
no ip http server
!
!
!
!
snmp-server manager
!
voice-port 1/0:15
!
voice-port 2/0/0
!
voice-port 2/0/1
!
voice-port 2/1/0
!
voice-port 2/1/1
!
voice-port 3/0:23
!
dial-peer cor custom
!
!
!
dial-peer voice 1 pots
application mgcp
!
dial-peer voice 3 pots
application mgcpapp
port 2/0/1
!
dial-peer voice 2 pots
application mgcpapp
port 2/0/0
!
dial-peer voice 999200 pots
application mgcpapp
port 2/0/0
!
dial-peer voice 9991015 pots
application mgcpapp
port 1/0:15
!
dial-peer voice 9993023 pots
application mgcpapp
port 3/0:23
!
!
line con 0
line aux 0
line vty 0 4
login
!
!
end

MGCP_3640#sh run
Building configuration...

Current configuration : 2266 bytes
!
version 12.2
no parser cache
no service single-slot-reload-enable
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
no service dhcp
!
hostname MGCP_3640
!
logging rate-limit console 10 except errors
!
!
!
voice-card 1
!
voice-card 3
!
ip subnet-zero
!
!
!
no ip dhcp-client network-discovery
mgcp
mgcp call-agent 10.1.1.2 2427 service-type mgcp version 0.1
mgcp dtmf-relay voip codec all mode out-of-band
mgcp rtp unreachable timeout 1000 action notify
mgcp modem passthrough voip mode cisco
mgcp sdp simple
mgcp package-capability rtp-package
mgcp package-capability sst-package
no mgcp timer receive-rtcp
no mgcp explicit hookstate
isdn switch-type primary-ni
call rsvp-sync
!
!
!
!
!
ccm-manager mgcp
ccm-manager music-on-hold
ccm-manager config server 10.1.1.2
ccm-manager config
!
!
controller E1 1/0
pri-group timeslots 1-31 service mgcp
!
controller E1 1/1
!
controller T1 3/0
framing esf
linecode b8zs
pri-group timeslots 1-24 service mgcp
!
controller T1 3/1
framing sf
linecode ami
!
!
!
interface Ethernet0/0
ip address 10.1.1.200 255.255.255.0
no ip mroute-cache
half-duplex
!
interface Ethernet0/1
ip address 171.69.231.23 255.255.255.0
no ip mroute-cache
half-duplex
!
interface Serial1/0:15
no ip address
no logging event link-status
isdn switch-type primary-net5
isdn incoming-voice voice
isdn T310 4000
isdn bind-l3 ccm-manager
no cdp enable
!
interface Serial3/0:23
no ip address
no logging event link-status
isdn switch-type primary-ni
isdn protocol-emulate network
isdn incoming-voice voice
isdn T306 30000
isdn T310 40000
isdn bind-l3 ccm-manager
no cdp enable
!
ip classless
no ip http server
!
!
!
!
snmp-server manager
!
voice-port 1/0:15
!
voice-port 2/0/0
!
voice-port 2/0/1
!
voice-port 2/1/0
!
voice-port 2/1/1
!
voice-port 3/0:23
!
dial-peer cor custom
!
!
!
dial-peer voice 1 pots
application mgcp
!
dial-peer voice 3 pots
application mgcpapp
port 2/0/1
!
dial-peer voice 2 pots
application mgcpapp
port 2/0/0
!
dial-peer voice 999200 pots
application mgcpapp
port 2/0/0
!
dial-peer voice 9991015 pots
application mgcpapp
port 1/0:15
!
dial-peer voice 9993023 pots
application mgcpapp
port 3/0:23
!
!
line con 0
line aux 0
line vty 0 4
login
!
!
end

MGCP_3640#

hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Sep 6 13:20:00 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.