Table Of Contents
Cisco Systems Hardware and Software Requirements
PBX Hardware and Software Requirements
Calling Name and Number feature
Configuring the Siemens Hicom 330 E PBX
Siemens Hicom 330 E PBX Configuration Menus and Commands
Configuring the Cisco CallManager
Siemens Hicom 330 E Software release
Catalyst 6000 Switch Configuration
Application Note
Siemens Hicom 330 E Rel 3.1 PBX with CallManager using 6608-E1 PRI EURO Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1 PBX with Cisco CallManager using Cisco 6608-E1 PRI Euro Gateway.
I
Integration Description
Connectivity is achieved by using the ETSI standard PRI protocol. The Siemens Hicom 330 E can be configured as either NETWORK or USER side.
Cisco Systems Hardware and Software Requirements
•Hardware (Gateway): 6608 E1 Port
•Software: CallManager Release 3.1
PBX Hardware and Software Requirements
•Hardware: DTU-N2
•Software: Version 3.1
Features Supported
Key Features Supported
Calling/Called Number
Key Features Not Supported
Calling/Called Name
Limitations
Calling Name and Number feature
•Calling Name delivery and presentation features are not supported by the Siemens Hicom 330 E PBX.
•When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called Number is displayed on both phones after the call is answered as expected.
•When calling from Siemens digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Siemens phone however does NOT get updated when the call is answered. It displays the numbers being dialed instead. (i.e. Access Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending "Connected Number" information in the connect message back to PBX.
Network Topology
Figure 1 Basic Setup
Configuration
Configuring the Siemens Hicom 330 E PBX
Use the following steps to configure the Siemens Hicom 330 E PBX.
Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.
Step 2. Add the new trunk board using BCSU.
Step 3. Configure Class of Trunk using COT.
Step 4. Configure Class of Parameter for device handler using COP.
Step 5. Configure Class of Service using COSSU.
Step 6. Add the new trunk group access code using BUEND.
Step 7. Configure trunk using TDCSU.
Step 8. Configure Reference Clock using REFTA.
Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.
Step 10. Configure LCR Out-dial Rules using LODR.
Siemens Hicom 330 E PBX Configuration Menus and Commands
Step 1. Add the new access code to Dialing Plans using WABE + LDPLN.
<dis-wabe
TYPE = gen
CD =
DPLN = 0;
DIS-WABE:GEN,,0;
H500: AMO WABE STARTED
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 001 - 002 |* ..... ..... ..... ..... ..| NETRTE | |
| 11 |. ..... ..... ..... ....* ..| MBKY | |
| 3001 |. .**** ***** **... ..... ..| STN | R |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 3007 |. ..... ..... ..... ....* ..| MBKY | |
| 3007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 |
| | | |DNNO 1- 1-150*|
| 4100 - 4500 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 72 |
| | | |DNNO 1- 1-702 |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 5000 - 5007 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 0 | | | | |DNNO 1- 1-150*| | 5008 - 5009 |. .**** ***** **... ..... ..| STN | |
| | | |DESTNO 99 |
| | | |DNNO 1- 1- 99 |
| 5010 |. .**** *.*** **... ..... ..| ATNDIND | |
| 800 |. ..... *...* **... ..... ..| ATNDDID | |
| 854 |. .**** ***** **... ..... ..| NETW | R |
| | | |DESTNO 2 |
| | | |DNNO 0- 0- 0 |
| *66 |. ....* ..... ..... ..... ..| SIGNON | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *91 |. ....* ....* ..... ..... ..| MBOFF | |
| #66 |. ....* ..... ..... ..... ..| SIGNOFF | | | #91 |. ....* ....* ..... ..... ..| MBON | |
| ##22 |. ..... ..... ..... ....* ..| DAKY | |
| ##24 |. ..... ..... ..... ....* ..| DSSKY | |
| ##25 |. ..... ..... ..... ....* ..| FWDKY | |
| ##26 |. ..... ..... ..... ....* ..| HTKY | |
| ##27 |. ..... ..... ..... ....* ..| KNOVRKY | |
| ##28 |. ..... ..... ..... ....* ..| MBKY | |
| ##29 |. ..... ..... ..... ....* ..| MSGRKY | |
| ##35 |. ..... ..... ..... ....* ..| TIMEKY | |
| ##36 |. ..... ..... ..... ....* ..| VCKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##37 |. ..... ..... ..... ....* ..| VCRKY | |
| ##38 |. ..... ..... ..... ....* ..| CCKY | |
| ##39 |. ..... ..... ..... ....* ..| CONFKY | |
| ##41 |. ..... ..... ..... ....* ..| NAMEKY | |
| ##42 |. ..... ..... ..... ....* ..| PARKKY | |
| ##43 |. ..... ..... ..... ....* ..| REMKY | |
| ##44 |. ..... ..... ..... ....* ..| STKY | |
| ##45 |. ..... ..... ..... ....* ..| CBKKY | |
| ##46 |. ..... ..... ..... ....* ..| CONSKY | |
| ##47 |. ..... ..... ..... ....* ..| DNDKY | |
| ##48 |. ..... ..... ..... ....* ..| EXHOLDKY | |
| ##49 |. ..... ..... ..... ....* ..| HOLDKY | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
-----------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| ##50 |. ..... ..... ..... ....* ..| IUSEKY | |
| ##51 |. ..... ..... ..... ....* ..| LNRKY | |
| ##52 |. ..... ..... ..... ....* ..| PRIVKY | |
| ##53 |. ..... ..... ..... ....* ..| RLSKY | |
| ##54 |. ..... ..... ..... ....* ..| SNRKY | |
| ##55 |. ..... ..... ..... ....* ..| TRNSKY | |
| ##56 |. ..... ..... ..... ....* ..| RCTOFFKY | |
| ##57 |. ..... ..... ..... ....* ..| TOGGLEKY | |
------------------------------------------------------------------------------
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 0 |. ..... *.... ..... ..... ..| ATNDDID | |
| 0 |. ....* ..*** **... ..... ..| ATND | |
| 150 |. .**** ***** **... ..... ..| OWNNODE | |
| 31 |. .**** ***** **... ..... ..| TIE | |
| 37 - 38 |. .**** ***** **... ..... ..| TIE | |
| 40 |. .**** ***** **... ..... ..| TIE | |
| 702 |. .**** ***** **... ..... ..| TIE | |
| 9 |. .**** ..*** **... ..... ..| CO | |
| *0 |. *.... ..*.. ....* ..... ..| ACBK | |
| *10 |. ....* ....* **... ..... ..| CCMANS | R |
| *11 |. ....* ..... ....* ..... ..| AFWDVCE | |
| *12 |. ....* ..... ....* ..... ..| AFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *13 |. ....* ..... ..... ..... ..| AFWDDWD | |
| *14 |. .**** ***** **..* ..... ..| AFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *15 |. *...* ..**. ..... ..... ..| APRIV | |
| *16 |. ....* ..... ..... ..... ..| PUGDIS | |
| *17 |. *.... ..**. ..... ..... .*| SPLIT | |
| *18 |. *.... ..**. ..... ..... ..| TRACE | |
| *19 |. ....* ..... ....* ..... ..| AREM | |
| *20 |. ...** ..... ..... ..... ..| NOPT | |
| *21 |. ....* ..... ....* ..... ..| AFFWDVCE | |
| *22 |. ....* ..... ....* ..... ..| AFFWDDTE | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *23 |. *...* ..**. ..... ..... ..| CALLPARK | |
| *24 |. ....* ..**. ..... ..... ..| DISUON | |
| *3 |. .**** ..**. ..... ..... ..| PUDIR | |
| *40 |. ....* ....* **... ..... ..| CCANS | R |
| *41 |. ..... ..... ..... ..*.. ..| CCDIS | |
| *43 |. .**.* *...* **... ..... ..| DTE | |
| *44 |. .**** ***** **..* ..... ..| FWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| *45 |. ..... ..... ..... ..*.. ..| CCMEETME | |
| *46 |. ***** *.*** **... ..... ..| CCSCD | R |
| *47 |. ..... ..... ..... ..*.. ..| CCSURG | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *48 |. ..... ..... ..... ..*.. ..| CCVCE | |
| *49 |. ....* ..... ..... ..... ..| ACOSX | |
| *50 |. ....* ..**. ..... ..... ..| FWDIGNOR | |
| *51 |. ....* ..... ..... ..... ..| ADND | |
| *52 |. ....* ..... ..... ..... ..| AHTVCE | |
| *53 |. ***** *.*** **... ..... ..| CCMSURG | R |
| *54 |. ....* ..... ..... ..... ..| SPD | |
| *55 |. *...* ..**. ..... ..... ..| BABYLSNG | |
| *56 |. ***** *.*** **... ..... ..| CCMS | R |
| *57 |. ..... ..... ..... ..*.. ..| CCS | |
| *58 |. ***** *.*** **... ..... ..| CCSN | R |
| *59 |. ..... ..... ..... ..*.. ..| CCSTN | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *60 |. *.... ..... ..... ..... ..| KNOVR | |
| *61 |. .**** ..*** **... ..... ..| SPDC1 | |
| *62 |. .**** ..*** **... ..... ..| SPDC2 | |
| *63 |. .**.* ..**. ..... ..... ..| SPDI | |
| *64 |. ....* ..... ....* ..... ..| SPDIPROG | |
| *69 |. *.... ..**. ..... ..... ..| EOVR | |
| *7 |. *...* ..**. ..... ..... .*| LNR | |
| *81 |. ....* ..**. ..... .*... ..| APIN1 | |
| *82 |. ....* ..**. ..... .*... ..| APIN2 | |
| *83 |. ....* ..**. ..... .*... ..| APIN3 | |
| *84 |. ....* ..**. ..... .*... ..| APIN4 | |
| *85 |. ....* ..**. ..... .*... ..| APIN5 | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *88 |. ...** ....* *.... ..... ..| CTLS | |
| *89 |. ..*.. *...* *.... ..... ..| TESTLN | |
| *9 |. *.... ..... ..... ..... ..| CONF3 | |
| ** |. ....* ..... ..... ..... ..| PU | | | *#50 |. *...* ..**. ..... ..... .*| ACDLOGON | |
| *#51 |. *...* ..**. ..... ..... .*| ACDAV | |
| *#52 |. *...* ..**. ..... ..... .*| ACDWORK | |
| *#53 |. *...* ..**. ..... ..... .*| ACC | |
| *#54 |. ....* ..... ..... ..... ..| MONSLNT | |
| *#55 |. ....* ..... ..... ..... ..| MONTONE | |
| *#60 |. *...* ..**. ..... ..... ..| ACDPGS | | | *#61 |. *...* ..**. ..... ..... ..| ACDPQS | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| *#62 |. ....* ..... ..... ..... ..| ACDEMMSG | |
| *#63 |. ....* ..... ..... ..... ..| ACDSHMSG | |
| *#71 |. *...* ..**. ..... ..... ..| CAFAV | |
| *#72 |. *...* ..**. ..... ..... ..| CAFGRAV | | | *#74 |. *...* ..**. ..... ..... ..| CAFAFWD | | | #0 |. ....* ..... ..... ..... ..| DCBK | | | #11 |. ....* ..... ..... ..... ..| DFWDVCE | |
| #12 |. ....* ..... ..... ..... ..| DFWDDTE | |
| #14 |. .**** ***** **..* ..... ..| DFWDREM | |
| | | |CFREMVAR CFU |
| | | |CFREMSE VOICE |
| #15 |. *...* ..**. ..... ..... ..| DPRIV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #19 |. ....* ..... ..... ..... ..| DREM | |
| #21 |. ....* ..... ..... ..... ..| DFFWDVCE | | | #22 |. ....* ..... ..... ..... ..| DFFWDDTE | |
| #24 |. ....* ..**. ..... ..... ..| DISUOFF | |
| #49 |. ....* ..... ..... ..... ..| DCOSX | |
| #51 |. ....* ..... ..... ..... ..| DDND | |
| #52 |. ....* ..... ..... ..... ..| DHTVCE | |
| #74 |. ....* ..... ..... ..... ..| DIGIDAT | |
| #8 |. ....* ..**. ..... .*... ..| DPIN | |
| #92 |. ....* ....* ..... ..... ..| MBOFF | |
| #*50 |. *...* ..**. ..... ..... .*| ACDLOGOF | |
| #*51 |. *...* ..**. ..... ..... .*| ACDNAV | |
------------------------------------------------------------------------------
| DIGIT INTERPRETATION DPLN 0 |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| #*60 |. *...* ..**. ..... ..... ..| ACDSGS | |
| #*61 |. *...* ..**. ..... ..... ..| ACDSQS | |
| #*70 |. *...* ..**. ..... ..... ..| CAFLOGOF | |
| #*71 |. *...* ..**. ..... ..... ..| CAFNAV | |
| #*72 |. *...* ..**. ..... ..... ..| CAFGRNAV | |
| #*73 |. *...* ..**. ..... ..... ..| CAFGROFF | |
| #*74 |. *...* ..**. ..... ..... ..| CAFDFWD | |
| ##1 |. ..... ..... ....* ..... ..| KYPROG | |
| ##40 |. ..... ..... ..... ....* ..| NAKYLO | |
| ##7 |. ....* ....* ..... ..... ..| MBON | |
| ##8 |. ....* ....* ..... ..... ..| MBOFF | |
------------------------------------------------------------------------------
AMO-WABE -107 DIALLING PLANS, FEATURE ACCESS CODES
DISPLAY COMPLETED;
<dis-ldpln
TYPE = ldp
M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS
LDPNO = 47;
DIS-LDPLN:LDP,47;
H500: AMO LDPLN STARTED
+--------------+------------------------------------------+
| | |
| LDPNO : 47 | LDP : 37-XXXX |
| | SPC : 22 |
+--------------+------+------+------++------+------+------+
| | DPLN | LRTE | LAUTH|| DPLN | LRTE | LAUTH|
| +------+------+------++------+------+------+
| | 0 | 37 | 1 || 8 | | |
| | 1 | | || 9 | | |
| | 2 | | || 10 | | |
| | 3 | | || 11 | | |
| | 4 | | || 12 | | |
| | 5 | | || 13 | | |
| | 6 | | || 14 | | |
| | 7 | | || 15 | | | +--------------+------+------+------++------+------+------+
AMO-LDPLN-107 ADMINISTRATION LCR DIALPLAN
DISPLAY COMPLETED;
Step 2. Add the new trunk board using BCSU.
<dis-bcsu
TYPE = tbl
LTG = 1
LTU = 1
SLOT = 73;
DIS-BCSU:TBL,1,1,73;
H500: AMO BCSU STARTED
ADDRESS : LTG 1 LTU 1
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
73 | Q2196-X DIU-N2 1 A | | Q2196-X | 1 | -04 - | READY |
AMO-BCSU -107 BOARD CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Step 3. Configure Class of Trunk using COT.
<dis-cot
COTNO = 4;
DIS-COT:4;
H500: AMO COT STARTED
COT: 4 INFO: 4:Q931 EXTERNAL
DEVICE: INDEP SOURCE: DB
PARAMETER:
PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRI
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
DON'T RELEASE CALL TO BUSY HUNT GROUP BSHT
SEND NO NODE NUMBER TO PARTNER LWNC
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
INCOMING CDR BY ZONE OR FROM LINE ICZL
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
INTERWORKING CALLBACK - NO ANSWER AND MAILBOX CALLBACK IWCB
AOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCC
CONTROLLED TRUNK AND LINE SELECTION CTLS
NO TONE NTONAMO-COT -107 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;
Step 4. Configure Class of Parameter for device handler using COP.
<dis-cop
COPNO = 4;
DIS-COP:4;
H500: AMO COP STARTED
COP: 4 INFO: 4:Q931
DEVICE: INDEP SOURCE: DB
PARAMETER:
SPECIAL MODE SFRM
REGISTRATION OF LAYER 3 ADVISORIES L3AR
AMO-COP -107 CLASS OF PARAMETER FOR DEVICE HANDLER
DISPLAY COMPLETED;
Step 5. Configure Class of Service using COSSU.
<dis-cossu
TYPE = cos
COS = 32;
DIS-COSSU:COS,32;
H500: AMO COSSU STARTED
+------+----------+---------+---------+---------+----------+
| COS | VOICE | FAX | TTX | VTX | DTE |
+------+----------+---------+---------+---------+----------+
| 32 |>32:TRUNKS |
| | TA | NOCO | NOCO | NOCO | TA |
| | TNOTCR | NOTIE | NOTIE | NOTIE | TNOTCR |
| | | | | | BASIC |
| | | | | | MSN |
| | | | | | CDRINT |
| | | | | | MULTRA |
| | | | | | |
+------+----------+---------+---------+---------+----------+
AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT
DISPLAY COMPLETED;
<dis-cossu
TYPE = lcos
LCOS = 31;
DIS-COSSU:LCOS,31;
H500: AMO COSSU STARTED
THE LCR CLASSMARKS ARE CONTAINED IN THE FOLLOWING LCOS:
+----+-----------------------------------------------------------------+
|LCOS| LCOSV | LCOSD |
| |12345678901234567890123456789012|12345678901234567890123456789012|
| |>SERVICE INFORMATION |
+----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+
| 31| XX| XX|
+----+-----------------------------------------------------------------+
AMO-COSSU-82 CLASSES OF SERVICE, SWITCHING UNIT
DISPLAY COMPLETED
Step 6. Add the new trunk group access code using BUEND.
<dis-buend
TGRP = 37
FORMAT = ;
DIS-BUEND:37,;
H500: AMO BUEND STARTED
+------------------------------- FORMAT = L -----------------------------------+
| TGRP NUMBER : 37 TGRP NAME : PRI MAXIMUM NO. : 30 |
| SUBGROUP NO.: 10 DEVICE TYPE : S2CONN TRACENO : 0 |
| RESERVED : N SEARCH MODE : CIRCULAR ACD THRESHOLD : * |
| NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 1 |
| THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 1- 73-0 B-CHL: 1 | 1- 1- 73-0 B-CHL: 2 | 1- 1- 73-0 B-CHL: 3 |
| 1- 1- 73-0 B-CHL: 4 | 1- 1- 73-0 B-CHL: 5 | 1- 1- 73-0 B-CHL: 6 |
| 1- 1- 73-0 B-CHL: 7 | 1- 1- 73-0 B-CHL: 8 | 1- 1- 73-0 B-CHL: 9 |
| 1- 1- 73-0 B-CHL: 10 | 1- 1- 73-0 B-CHL: 11 | 1- 1- 73-0 B-CHL: 12 |
| 1- 1- 73-0 B-CHL: 13 | 1- 1- 73-0 B-CHL: 14 | 1- 1- 73-0 B-CHL: 15 |
| 1- 1- 73-0 B-CHL: 16 | 1- 1- 73-0 B-CHL: 17 | 1- 1- 73-0 B-CHL: 18 |
| 1- 1- 73-0 B-CHL: 19 | 1- 1- 73-0 B-CHL: 20 | 1- 1- 73-0 B-CHL: 21 |
| 1- 1- 73-0 B-CHL: 22 | 1- 1- 73-0 B-CHL: 23 | 1- 1- 73-0 B-CHL: 24 |
| 1- 1- 73-0 B-CHL: 25 | 1- 1- 73-0 B-CHL: 26 | 1- 1- 73-0 B-CHL: 27 |
| 1- 1- 73-0 B-CHL: 28 | 1- 1- 73-0 B-CHL: 29 | 1- 1- 73-0 B-CHL: 30 |
+------------------------------------------------------------------------------+AMO-BUE ND-107 TRUNK GROUP
DISPLAY COMPLETED;
Step 7. Configure trunk using TDCSU.
For Master Side Configuration
<dis-tdcsu
PEN1 = 1-1-73-0;
DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 4 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKS
DISPLAY COMPLETED;
<dis-lwpar
INFOPAT = 4
FORMAT = l
DEV = ;
DIS-LWPAR:4,L,;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 4 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = Y DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = Y PERMACT = Y FCBAB = DFH |
| CDG = Y FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 4:COPPER-MASTER CLOCK(DPNSS A-END) |
+-----------------------------------------------------------------------+
AMO-LWPAR-70 LOADWARE PARAMETERS FOR NETWORKING MODULES
DISPLAY COMPLETED;
For Slave Side Configuration
<dis-tdcsu
PEN1 = 1-1-73-0;
DIS-TDCSU:1-1-73-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-01-073-0 |
|---------------------------------------------------------------------------|
| COTNO = 4 COPNO = 4 DPLN = 0 |
| ITR = 0 COS = 32 LCOSV = 31 |
| LCOSD = 31 CCT = PRI DESTNO = 99 |
| PROTVAR = ETSI SEGMENT = 1 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNCC = ISDNAC = ISDNLC = |
| ISDNIP = ISDNNP = |
| PNPL2C = PNPL1C = PNPLC = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -999 |
| ALARMNO = 2 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 4 FWDX = 10 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = |
| CCHDL = UUSCCX = 16 UUSCCY = 8 |
|---------------------------------------------------------------------------|
| TGRP = 37 SRCHMODE = CIR BCNEG = N |
| BCGR = 1 INS = Y LWPAR = 1 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| BCHAN 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30AMO-TDCSU-107 DIGITAL TRUNKS
DISPLAY COMPLETED;
DIS-LWPAR:1,L,;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = N DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = N PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = 1:COPPER-DERIVE CLOCK FROM LINE(I421) |
+-----------------------------------------------------------------------+
AMO-LWPAR-104 LOADWARE PARAMETERS FOR NETWORKING MODULES
DISPLAY COMPLETED;
Step 8. Configure Reference Clock using REFTA.
For Master Side Configuration
<dis-refta
TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;
H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 0 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;
For Slave Side Configuration
<dis-refta
TYPE = circuit
PEN = 1-1-73-0;
DIS-REFTA:CIRCUIT,1-1-73-0;
H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+------+--------+------+--------+-----+
| PEN | MODULE | DEVICE | PRI | ERROR |BLOCK | SUPP. |READY|
| | | | | | | |BUT |
| | | | | | | |ASYN.|
+--------------+---------+----------+------+--------+------+--------+-----+
| 1- 1- 73- 0 | DIU-N2 | S2CONN | 11 | 15485 | N | X | N |
+--------------+---------+----------+------+--------+------+--------+-----+AMO-REFTA-89 REFERENCE CLOCK TABLE
DISPLAY COMPLETED;
Step 9. Configure trunk Least Cost Routing using LDAT + RICHT.
LDAT
<dis-ldat
TYPE = lcr
LROUTE = 37;
DIS-LDAT:LCR,37;
H500: AMO LDAT STARTED
+--------------------------------------------------------------------------+
| LROUTE = 37 LDPLN NAME = PRI TEST SERVICE = ALL |
| TYPE = LCR DNNO OF ROUTE = 1 -1 -999 |
| SERVICE INFO = |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| | | | | | SCHEDULE | CARRIER |BAND| |
| LRTEL | LVAL | TGRP | ODR |LAUTH| ABCDEFGH | ZONE |WDTH| LATTR |
+-------+-------+-------+-----+-----+----------+------------+----+---------+
| 1 | 1 | 37 | 1 | 1 | ******** | 1 EMPTY | 1 | NONE |
+-------+-------+-------+-----+-----+----------+------------+----+---------+AMO-LDAT -107 LCR-DIRECTIONS
DISPLAY COMPLETED;
RICHT
<dis-richt
MODE = lrte
LRTE = 37;
DIS-RICHT:LRTE,37;
H500: AMO RICHT STARTED
+---------------------------------------------------------------+
| LRTE = 37 NAME = PRI TEST SRVC = ALL |
| DNNO = 1 -1 -999 |
| ROUTOPT = NO REROUT = YES PLB = NO FWDBL = NO |
| MFV: CNV=FIX DSP=WITHOUT TEXT= PULS=PP300 |
| ROUTENO = 4 BUGS = LIN MAINGROUP = 4 |
| INFO = |
+---------------------------------------------------------------+
| TGRP = 37 LDAT PRI SUBGROUP = 10 |
+---------------------------------------------------------------+AMO-RICHT-107 TRUNK ROUTING
DISPLAY COMPLETED;
Step 10. Configure LCR Out-dial Rules using LODR.
<dis-lodr
ODR = 1
INFOPAT = ;
DIS-LODR:1,;
H500: AMO LODR STARTED
+-------------------------------------------------------+
| ODR POSITION CMD PARAMETER |
+--------+----------------------------------------------+
| 1 | 1 ECHO 2 |
| | 2 END |
+--------+----------------------------------------------+
|INFO:PSTN |
+-------------------------------------------------------+
H03: THE NEXT FREE ODR IS 3AMO-LODR -107 ADMINISTRATION OF LCR OUTDIAL RULES
DISPLAY COMPLETED;
<
Configuring the Cisco CallManager
Figure 1
Configuring the 6608-E1 Gateway
Route Pattern Configuration
Test Results
As shown in the diagram below, a Siemens Hicom 330 E PBX was connected via an ISDN E1 PRI link to a Cisco 6608-E1 Gateway, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 6608-E1 and the PBX.
Test Configuration
Layer 1 (Physical Layer)
The Siemens configuration screen for the E1 trunk interface is reached with the following command:
<cha-tdcsu
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/6608-E1 software configuration properly exchanged SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 6608-E1 Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 6608-E1 Gateway with ISDN protocol type setting of PRI-EURO supports both protocol sides by selecting "Network/User" in the protocol side field when configuring the Gateway via CallManager.
The "Network/user" or Master/Slave choice for the Siemens Hicom 330 E PBX is made by deactivating the B channels/D-channel (<dea-dssu). A change command is then issued to the Reference clock (<cha-refta) to get to the Master/Slave selection (Pri=0 for Master, 11 for slave). Now the trunk is changed (<cha-tdcsu) to get to Device type prompt (Dev=s2conn), (Bcgrp=1), and loadware parameters (Lwpar=1 for Slave, 4 for Master). The D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
Table 2 Basic Calls: (Enbloc Sending)
Calls Made Call Comp? "Calling Number" Passed to Final Destination? "Calling Name" Passed to Final Destination? "Called Number" Passed to Orig. Side? "Called Name" Passed to Orig. Side? NotesPhone A to Phone C
Yes
Yes
No
No 1
No
Phone C to Phone A
Yes
Yes
No
Yes
No
1 CallManager is not sending "Connected Number" information in the connect message back to PBX.
2 The Siemens PRI interface with ETSI setting does not support "Calling Name" presentation Feature.
Test Setup 2
Setup was as follows:
•PBX1 configured as ETSI, emulates User
•Cisco 6608-E1 Gateway configured as PRI EURO, emulates Network
.
Table 6 Switch and Gateway Settings
Siemens Hicom 330 E Switch-type/ Protocol side setting Cisco 6608-E1 ISDN protocol-type/Protocolside settingETSO/Slave
PRI EURO / Network
The test results are the same as in previous section . Refer to Tables 2 through 5 for details.
Appendix A
Call Manager Software Release:
Siemens Hicom 330 E Software release
Software Release
--------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-10-15 11:36:52
-------------------------------------------------------------------------------- <dis-dbc
VERBOSE =
DIS-DBC:;
H500: AMO DBC STARTED
+------------------------------------------------------------------------------+
| SYSTEM CLASSIFICATION : SYSTEM 80 (H80 ) |
| HARDWARE ASSEMBLY : EXTENDED COMPACT CXE (CXE ) |
| DEVELOPMENT LINE : EUROPE DEVELOPMENT (H300) |
| OPERATING MODE : SIMPLEX |
| RESTART TYPE : SYM |
| HW-ARCHITECTURE : 330E |
| HW-ARCHITECTURE TYPE : 4 |
| |
| 'NO OF' HW VALUES |
| LTG'S : 1 LTU'S : 4 LOG.LINES : 8000 MTS BD /GSN: 1 |
| SIUP'S/LTU: 4 TMD24'S PER LTU: 4 PHYS.PORTS: 2688 HWY /MTS BD: 64 |
| HDLC /DCL : 5 PBC /DCL : 1 PBC'S : 17 |
| LOG. SIU LINES : 26 |
| LOG. CONF LINES : 35 |
| LOG. DCL LINES : 36 |
| DB DIMENSIONING-NAME : 350EMSTD CONF-TABLE VERSION: 1 |
| DB SUSY'S: |
| SWITCH NUMBER : L31900Q2999A00001 |
| LOCATION : CUSTOMER |
| BAPPL : 6ECXM48 |
| DBAPPL : 6ECXM48 |
| SYSTEM_ID : PKP091000 |
+------------------------------------------------------------------------------+
AMO-DBC -89 DATABASE CONFIGURATION
DISPLAY COMPLETED;
DIS-VEGAS;
H500: AMO VEGAS STARTED
SYSTEM NO. AMO APS NO. START USER STATUS
SWU: L31900Q2999A00001 REGEN P30252B4200B00103 14.11.00 14:33 DAVE A FINISHED
ADS: L31900Q2999A00001 REGEN P30252B4200A00103 14.11.00 14:35 DAVE A FINISHED
AMO-VEGAS-107 ADMIN. OF DATABASE GENERATION RUNS ON SUPPORT SYSTEM
DISPLAY COMPLETED;
<
Catalyst 6000 Switch Configuration
Console> (enable) sh version
WS-C6006 Software, Version NmpSW: 5.5(6a)
Copyright (c) 1995-2001 by Cisco Systems
NMP S/W compiled on Feb 23 2001, 10:23:18
System Bootstrap Version: 5.3(1)
Hardware Version: 2.0 Model: WS-C6006 Serial #: TBA04511172
Mod Port Model Serial # Versions
--- ---- ------------------- ----------- --------------------------------------
1 2 WS-X6K-SUP1A-2GE SAD05010NBK Hw : 7.0
Fw : 5.3(1)
Fw1: 5.4(2)
Sw : 5.5(6a)
Sw1: 5.5(6a)
WS-F6K-PFC SAD05020221 Hw : 1.1
3 48 WS-X6348-RJ-45 SAD04420N7B Hw : 1.4
Fw : 5.4(2)
Sw : 5.5(6a)
WS-F6K-VPWR Hw : 1.0
4 24 WS-X6624-FXS SAD050203M8 Hw : 3.0
Fw : 5.4(2)
Sw : 5.5(6a)
HP : A00203010010; DSP : A003E031 (3.3.
32)
5 8 WS-X6608-T1 SAD04400EM0 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)
6 8 WS-X6608-E1 SAD04380DW1 Hw : 1.1
Fw : 5.4(2)
Sw : 5.5(6a)
HP1: D00403010017; DSP1: D005E031 (3.3.
32)
HP2: D00403010017; DSP2: D005E031 (3.3.
32)
HP3: D00403010017; DSP3: D005E031 (3.3.
32)
HP4: D00403010017; DSP4: D005E031 (3.3.
32)
HP5: D00403010017; DSP5: D005E031 (3.3.
32)
HP6: D00403010017; DSP6: D005E031 (3.3.
32)
HP7: D00403010017; DSP7: D005E031 (3.3.
32)
HP8: D00403010017; DSP8: D005E031 (3.3.
32)
DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 65408K 37809K 27599K 16384K 11546K 4838K 512K 198K 314K
Uptime is 114 days, 6 hours, 11 minutes
Console> (enable)
______________________________________________________________________________
Console> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok
3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok
4 4 24 FXS WS-X6624-FXS no ok
5 5 8 T1 WS-X6608-T1 no ok
6 6 8 E1 WS-X6608-E1 no ok
Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD05010NBK
3 SAD04420N7B
4 SAD050203M8
5 SAD04400EM0
6 SAD04380DW1
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-04-c0-f8-42-02 to 00-04-c0-f8-42-03 7.0 5.3(1) 5.5(6a)
00-04-c0-f8-42-00 to 00-04-c0-f8-42-01
00-04-9b-f0-78-00 to 00-04-9b-f0-7b-ff
3 00-02-fc-20-5e-50 to 00-02-fc-20-5e-7f 1.4 5.4(2) 5.5(6a)
4 00-03-32-ba-2e-35 3.0 5.4(2) 5.5(6a)
5 00-01-c9-d9-3a-98 to 00-01-c9-d9-3a-9f 1.1 5.4(2) 5.5(6a)
6 00-01-c9-d8-63-3e to 00-01-c9-d8-63-45 1.1 5.4(2) 5.5(6a)
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD05020221 1.1
3 Inline Power Module WS-F6K-VPWR 1.0
Console> (enable)
______________________________________________________________________________
Console> (enable) sh port 6
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
6/1 connected 1 full 2.048 E1
6/2 notconnect 1 full 2.048 E1
6/3 notconnect 1 full 2.048 E1
6/4 notconnect 1 full 2.048 E1
6/5 notconnect 1 full 2.048 E1
6/6 notconnect 1 full 2.048 E1
6/7 notconnect 1 full 2.048 E1
6/8 notconnect 1 full 2.048 E1
Port DHCP MAC-Address IP-Address Subnet-Mask
-------- ------- ----------------- --------------- ---------------
6/1 enable 00-01-c9-d8-63-3e 10.1.1.104 255.255.255.0
6/2 enable 00-01-c9-d8-63-3f 10.1.1.118 255.255.255.0
6/3 enable 00-01-c9-d8-63-40 10.1.1.123 255.255.255.0
6/4 enable 00-01-c9-d8-63-41 10.1.1.117 255.255.255.0
6/5 enable 00-01-c9-d8-63-42 10.1.1.120 255.255.255.0
6/6 enable 00-01-c9-d8-63-43 10.1.1.121 255.255.255.0
6/7 enable 00-01-c9-d8-63-44 10.1.1.122 255.255.255.0
6/8 enable 00-01-c9-d8-63-45 10.1.1.124 255.255.255.0
Port Call-Manager(s) DHCP-Server TFTP-Server Gateway
-------- ----------------- --------------- --------------- ---------------
6/1 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/2 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/3 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/4 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/5 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/6 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/7 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
6/8 10.1.1.2 10.1.1.2 10.1.1.2 10.1.1.7
Port DNS-Server(s) Domain
-------- ----------------- -------------------------------------------------
6/1 - -
6/2 - -
6/3 - -
6/4 - -
6/5 - -
6/6 - -
6/7 - -
6/8 - -
Port CallManagerState DSP-Type
-------- ---------------- --------
6/1 registered C549
6/2 registered C549
6/3 registered C549
6/4 registered C549
6/5 registered C549
6/6 registered C549
6/7 registered C549
6/8 registered C549
Port NoiseRegen NonLinearProcessing
----- ---------- -------------------
6/1 enabled enabled
6/2 enabled enabled
6/3 enabled enabled
6/4 enabled enabled
6/5 enabled enabled
6/6 enabled enabled
6/7 enabled enabled
6/8 enabled enabled
Console> (enable)
Posted: Thu Sep 6 13:00:01 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.